FRP Cooling Towers, Cooling Towers, Air Cooled and Water Cooled Chilling Plants, Brine Chillers & Air Blast Coolers etc.
Company Information
Email: [email protected] or Phone : +91 98330948372
Member Of :
Email: [email protected] or Phone : +91 98330948373
01. Power Plant.
02. Steel Plant.
03. Chemical & Fertilizer industries
04. Cement Industries.
05. Pharmaceutical Industries
06. Machine Building Industries.
07. Petroleum Industries
08. Air Condition & Refrigeration Plant.
09. Plastic & Rubber Industries.
10. Automobile Industries.
11. Induction Furnaces.
12. Process Plants.
13. Glass Industry.
14. Air Compressions.
15. Oxygen Plants.
16. Breweries & Distilleries.
17. Forgings Industries.
18. Paper Industries.
19. Textile Industries.
20. Food Processing Industries.
21. Sugar Industries.
22. Anodizing
23. D.G. Sets
24. HAVC
Plus many more process industries where hot water is need to be cool for process…
We are supplying to process industries like…
Email: [email protected] or Phone : +91 98330948374
Incepted in the year 1990, we at National Cooling Towers (ISO 9001:2008 certified company), have become one of the recognized firm engaged in designing manufacturing and erection of an exclusive range of reliable, tailor-made Water Cooling Towers (FRP Induced Draft Counter Flow, Timber Induced Draft Cross and Counter Flow, RCC Induced Draft Cross and Counter Flow ) plus Air Blast Coolers and Air and Water Chilling Plants.
Owing to our state-of-the-art manufacturing unit comprising latest machinery, we are able to fabricate high quality Cooling Towers & Air Blast Coolers and Chilling Plants as per CIT-USA,CE and ISO 9001:2008 standards. We undertake site supervision, erection, testing & commissioning. Our experience and qualified sales and service staff work in partnership with you to provide technical advice and field service support.
National Cooling Towers pays great attention to detail, using only high quality materials and submitting the produced machines and equipments to numerous checks and inspections. In this way, we are succeeding in combining reliability, high technology and simplicity of use with Zero maintenance.
We have a symbolic presence across the globe in the industry as our supplies of Cooling Towers have touched nearly 30000 and Chilling Plants 2000. Products deployed across the India and globe in high-profile customers.
National Cooling Tower make FRP Cooling Tower Detail View
Approved by…
Email: [email protected] or Phone : +91 98330948375
Approved by…
Email: [email protected] or Phone : +91 98330948376
National Cooling Tower make Air and Water Chillers Detail View
Why We Are ( Techno Commercial Compliance as per Your Expectations )
State-of-the-art infrastructure
We are using raw materials that have the appropriate properties and
high quality are attractive – and a necessity to ensure that the end
product maintains a high standard and is suitable for its purpose.
38000 + Satisfied Clients
GREEN BUILDING Installations
Major Exports in Africa, Middle East and Europe.
The demands are high, the problems varied. Our aim? To deliver a
perfect product that meets very exacting specifications.
Cooling System Design as per your requirement.
Next Page…
Email: [email protected] or Phone : +91 98330948377
Email: [email protected] or Phone : +91 98330948378
7)Cooling Towers are FRP make, having zero maintenance.
8)A close approach
9)Greater thermal efficiency
10)Higher energy saving
11)Ease of maintenance
12) Lower Drift Loss
13)Option for Cooling Towers with Centrifugal Fans for Noiseless
Operation
14)Longer working life for fans and motors, since handling dry air
15)Supply & Install at your site.
16)Upgrade/Reconstruction advised by our expertise.
17)Reconditioning as per your requirement.
18)Maintenance, repair and operations ( MRO)
19)Performance Testing & Vibration Analysis
20)Inspection Support and Training
Email: [email protected] or Phone : +91 98330948379
A) National Induced Draft Counter Flow Cooling Tower:- A) Other Cross Flow Cooling Tower
In the Induced Draft Counter Flow, always the dry air is in contact with the cool water emerging out from the PVC fills. That means when the air passes through the PVC fills the proper water to air contact occurs and the water evaporate. Thus it loses it heat energy and the moist air is thrown out which will not be re-circulating because the total height of the cooling tower is maintained for the fresh air to flow from the bottom.
It is a known fact that the cross flow cooling towers have the air entry from sides throughout & the distribution pans kept above the heat transfer area from the pan the hot water flow through the holes provided. The first layer of hot water which is falling down get in contact with the fresh dry air. It then extracts heat from the hot water and becomes moist and allows hot water to evaporate. Then hot water loses its heat and is collected in the basin. The second layer of hot water which is also flowing from the pan comes in contact with the same air which is moist and is with higher temperature. The rate of evaporation decreases and the water is not collected to the design outlet temperature because the approach decreases inside the cooling tower which effects the other layers of water & as the air passes inside the efficiency decreases & when the cold water is collected from the basin the temperature of water shall be the mean temperature of all the layers.
Induced Draft Counter Flow Cooling Tower:-The moist air thrown out through the fan stack takes a chance in re-circulating through the air entry sides because of high velocity and the low fan stack height. So always cross flow cooling towers does towers does require higher installed power then counter flow cooling tower. NATIONAL Cooling Tower required 1Ft. to 3Ft. clear space on each side. This results in considerable space saving.
Cross flow cooling tower have air inlet through louvers on sides and the air discharge is on the top. For proper performance of the tower above 6Ft. to 7Ft. clear space is required in front of the fan. For air inlet
Why Counter Flow is always better than Cross Flow. Page 1 based on Practical ( Important points to be consider before buying)
10
There are no louvers in NATIONAL Cooling Towers.
Cross flow cooling tower have louvers. This increase maintenance of the towers and the static pressure drop. Also the louvers are prone to breakage and therefore have to be replaced.
NATIONAL do not have water distribution exposed to the atmosphere.
Cross flow cooling towers have water distribution on top & header type which is exposed to sun. Due to this, chances of algae formation are increased. Also because of the exposed water distribution, dust tends to settle on the top and is circulated with cooling water. The dust and algae tend to depositing in air condenser chiller and compressor jackets, affecting heat transfer whereby discharge pressure will be more effects the performance of the air-conditioning plants.
NATIONAL Cooling Towers have Two inspection cum service windows. Through these windows the water spray and the PVC Fills packs can be observed and corrective action if required can be taken immediately. Through these windows packs can be removed easily for cleaning without disturbing the casing of the tower.
The removal of packs in cross flow cooling tower is very cumbersome & time consuming.
NATIONAL FRP Cooling Tower is very compact and very light weight.
Space requirement for cross flow cooling tower compare to NATIONAL FRP Cooling Tower is more
For National Cooling Towers Service & Maintenance is considerably reduced because fan is the only moving part in the cooling tower. The fills eliminator can easily be approached from the inspection window without disturbing the cooling tower casing. NATIONAL Cooling Towers have totally FRP casing. FRP materials are corrosive proof and does not warp and deteriorate and very compact, height, weight and user friendly by increasing the total efficiency of the systems by ensuring the air flow from all the four sides from the bottom portion and bringing proper contact between water film and air stream.
Why Counter Flow is always better than Cross Flow. Page 2 based on Practical ( Important)
Email: [email protected] or Phone : +91 9833094837
Email: [email protected] or Phone : +91 983309483711
Sr. No FRP Induced Draught Counter Flow Cooling Tower
Natural Draught Fan Motor Less Cooling Tower
1 Dissipation of latent heat load guaranteed during any climatic conditions.
Can not guarantee dissipation of latent heat load. The dissipation depend upon wet and dry bulb temperature.
2 Desired temperature dropped guaranteed. The temperature dropped is not constant and temperature dropped can not be achieved.
3 Evaporation and drift losses are maximum 0.80% to 1.00% on your circulation of flow
rate.
Evaporation and drift losses percentage average around 2.00% to 2.50% on circulation of water flow rate or even more depending upon
atmospheric seasonal wet and dry bulb temperature and due to wind velocity and height of Cooling Tower.
4 Less area required and limited height. Required more area and higher height.
5 Due to limited height the pump head is also required less in capacity.
Height is more. The pump head is also required in higher capacity.
6 Energy saving due to limited height, single header with 1/2” dia Spray Nozzles minimum
quantity of Nozzles required.
Energy required more to keep constant pressure for multiple water distribution header and multiple No. of Nozzles required to spray the
water to achieve breakage of water.7 Foreign particles accumulated is negligible
due to enclose body of Cooling Tower.Maximum open area. The accumulation of foreign particles is higher percentage, due to this Air-contaminated foreign particles the efficiency of Cooling Tower decreases day by day and chance of getting clogged of your process system incase any solid structural particles come into
contact of inside of Cooling Tower.8 Cooling Tower efficiency guaranteed
throughout working performance due to mechanical draught system.
No guarantee of performance due to Natural Draught climatic condition.
Comparative Evaluation Study between FRP Induced Draught Counter Flow Cooling Tower and Natural Draught Fan Motor Less Cooling Tower ( Important)
Email: [email protected] or Phone : +91 983309483712
SQUARE SHAPED BOTTLE (ROUND) SHAPED National design Cooling Tower is ONE peace mould construction. Square shaped the uniform thickness are maintained. We provide Pyramid type dome.
No. of segments are 10 to 12 and above casing. These segments are bottled shaped and neck type dome there are always possibilities of uneven thickness of casing.
Fix header water distribution system has uniform water distribution without loosing the pressure dropped due to fixed header system. No tension bar and no Ball Bearing are required.
The round shaped Cooling Tower consists of Rotary Sprinkler assembly with Ball Bearing System and Metal Tension Bar. The Cooling Tower water always contaminated with CaCo3. Due to contaminated water the bearings are likely to get jammed, corroded, worn out faster and over a period of used the tension of spring also get loose and its likely the reduces the desired ROTATION.
Fix header water distribution system with water inlet on the top and outlet in the basin is easy to maintain within limited time.
The water distribution system is on the bottom. To maintain this system is very difficult and consuming maximum time for servicing due to Arm Pipe gravity pressure system.
F Installation of the square shaped Cooling Tower is simple and easy. The Cooling Tower without FRP Basin can be rested on RCC basin. No chances of vibration, since the entire Cooling Tower rest on RCC basin, which maintain the uniform load distribution.
Installation of Bottled shaped Cooling Tower are provided with V bar metal support and in turn the V bar metal support are rested on RCC Pillars, Leaving the entire Cooling Tower hanging above the RCC Surface floor with the result the chances of vibrations are more.
To maintain Square Shaped Cooling Tower any of your workers can do the job due to the simple system.
You need to call trained personnel of Cooling Tower Company only.
Nozzles are provided with 2.5” Diameter the turbulence effect for water spray is absolute uniform over the Fills area. No possibilities of air pocket development.
With Rotary system water is just dropping from PVC Arm pipes with thick layer of water without getting water sprayed over the fills area, the chances of air pocket developments are maximum. Due to rotation of sprinkler Arms is being obstacle for dissipation of heat load generated in the Cooling Tower area. Due to the pressure drop the load increases on the fan to dissipate the heat load generated in the Cooling Tower with the result motor get tripped off frequently.
ABS 2.5” Dia Nozzles reduces frequency of clogging. Wide spray angle.Easy lock installation and Nozzles removal need no tools.Fills placement is uniform due to the square shaped of Cooling Towers. F Fills placement is not uniform due to round shaped. To place the fills on
round shaped is uneven and to fill the gap the fills segments are cut and placed with the result its likely that air pockets develop and as a result Tower efficiency is reduced.
Maintenance is easy due to easy access through window and can be carried out even when the Tower is in operation.
Maintenance is difficult due to fixed system of all components. No window is provided. Maintenance job cannot be carried out while the Tower is in operation.
To maintain Square shaped Cooling Tower any of your maintenance personnel can carry out the maintenance job.
You need to call trained personnel from the supplier of Cooling Tower.
COMPARATIVE STUDY BETWEEN Square Shaped and Bottle or Round Shape Cooling Towers
Email: [email protected] or Phone : +91 983309483713
01. Power Plant.
02. Steel Plant.
03. Chemical & Fertilizer industries
04. Cement Industries.
05. Pharmaceutical Industries
06. Machine Building Industries.
07. Petroleum Industries
08. Air Condition & Refrigeration Plant.
09. Plastic & Rubber Industries.
10. Automobile Industries.
11. Induction Furnaces.
12. Process Plants.
13. Glass Industry.
14. Air Compressions.
15. Oxygen Plants.
16. Breweries & Distilleries.
17. Forgings Industries.
18. Paper Industries.
19. Textile Industries.
20. Food Processing Industries.
21. Sugar Industries.
22. Anodizing
23. D.G. Sets
24. HAVC
Plus many more process industries where hot water is need to be cool for process…
We are supplying to process industries like…
Email: [email protected] or Phone : +91 9833094837
Email: [email protected] or Phone : +91 983309483715
Please Contact for Quotation in your budget
Thank You
www.nationalcoolingtowers.com
National Cooling Towers