ΠΡΟΤΥΠΑ ELOT
Transcript of ΠΡΟΤΥΠΑ ELOT
-
7/22/2019 ELOT
1/16
. . - C. E. N.
TC 70Manual means of fire fighting equipment
[ ]
TC 72Automatic fire detection systems()
TC 127Fire safety in buildings()
TC 191Fixed firefighting systems[() ]
TC 192Fire service equipment( E)
1997
-
7/22/2019 ELOT
2/16
TC 70Manual means of fire fighting equipment( )
EN 2 10/92 A: : :
.
Classification of fires.
pr EN 3-1 2/96 A: : :
. 1:, , .
Portable fire extinguishers.Part 1 : Description, duration of operation, class A and B fire test.
pr EN 3-2 review 6/95 A: : :
. 2: (), ,
, .
Portable fire extinguishers.Part 2 : Tightness, dielectric test, tamping test, special provisions
pr EN 3-3 / ELOT 286.3 1/93 A: : :
. 3: , ,
Portable fire extinguishers.Part 3 : Construction, resistance to pressure, mechanical tests.
pr EN 3-4 review 6/95 A: : :
. :, .
Portable fire extinguishers.Part 4 : Charges, minimum required fire.
-
7/22/2019 ELOT
3/16
pr EN 3-5 review 6/95 A: : :
. 5:.
Portable fire extinguishers.Part 5 : Specification and Supplementary tests.
pr EN 3-6 1/97 A: : :
. 6:
o 3 1 5.
Portable fire extinguishers.Part 6 : Provisions for the attestation of conformity of portable fire extinguishers in
accordance with EN 3 part 1 to part 5.
E 1066 12/88 A: : :
().
Small disposable fire extinguishers of the aerozol type.
pr EN 1866 5/97 A: : :
.
Mobile fire extinguishers.
pr EN 1869 8/96 A: : :
() .
Fire blankets.
pr EN 12367 4/96 A: : :
.
Maintenance for portable fire extinguishers.
-
7/22/2019 ELOT
4/16
TC 72Automatic fire detection systems( )
EN 54-1 10/76 A: : :
. 1: .
Components of automatic fire detection systems.Part 1 : Introduction.
pr EN 54-2 8/96 A: : :
. 2: .
Fire detection and fire alarm systems.Part 3 : Control and indicating equipment.
pr EN 54-3 11/95 A: : :
.
3: .
Fire detection and fire alarm systems.Part 3 : Audible fire alarm devices.
pr EN 54-4 8/96 A: : :
. 4: .
Fire detection and fire alarm systems.Part 4 : Power supply equipment.
pr EN 54-5 11/94 A: : :
. 5: - .
Fire detection and fire alarm systems.
Part 5 : Heat detectors - Point detectors
-
7/22/2019 ELOT
5/16
EN 54-6 4/88 A: : :
. 6: :
Fire detection and fire alarm systems.Part 6 : Heat sensitive detectors: Rate-of-rise point detectors without a static element.
pr EN 54-7 11/94 A: : :
. 7: : ,
.
Fire detection and fire alarm systems.Part 7 : Smoke detectors: point detectors using scattered light, transmitted light or
ionization
EN 54-8 7/82 A: : :
. 8: .
Components of automatic fire detection systems.Part 8 : High temperature heat detectors.
pr EN 54-10 6/91 A: : :
. 10:.
Components of automatic fire detection systems.Part 10 : Flame detectors.
pr EN 54-11 8/96 A: : :
. 11:Ko.
Fire detection and fire alarm systems.Part 11 : Manual call points.
pr EN 54-13 8/96 A: : :
. 13: .
Fire detection and fire alarm systems.Part 13: System requirements
-
7/22/2019 ELOT
6/16
pr EN 54-14 8/96 A: : :
. 14: , , , ,
.
Fire detection and fire alarm systems.Part 14: Guidelines for planning, design, installation, commissioning, use andmaintenance
Draft ISO/DIS 12239 6/91 A: : :
E.- .
Fire protection equipment.Self-contained smoke alarms.
-
7/22/2019 ELOT
7/16
TC 127Fire safety in buildings( )
pr EN 1187-1 10/93 A: :
:
E. 1: (
), .
External fire exposure to roofsPart 1 : Method of test simulating exposure to burning brands without wind or
supplementary radiant heat.
pr EN 1187-2 10/94 A: : :
E. 1: (
), .
External fire exposure to roofsPart 1 : Method of test simulating exposure to burning brands with wind and
supplementary radiant heat.
pr EN 1188-6 10/93 A: : :
() . 6:M ().
Fire resistance tests on loadbearing elements.Part 6 : Method of test for fire resistance of columns.
pr EN 1363-1 11/93 A: : :
. 1:.
Fire resistance tests on elements of building construction.Part 1 : Alternative and additional procedures.
pr EN 1364-1 11/93 A: : :
. 1: ().
Fire resistance tests on non-loadbearing elements in buildings.Part 1 : Partitions.
pr EN 1364-2 6/94 A: :
-
7/22/2019 ELOT
8/16
:
. 2:E.
Fire resistance tests on non-loadbearing elements in buildings.Part 2 : External walls .
pr EN 1364-3 6/94 A: : :
. 3:.
Fire resistance tests on non-loadbearing elements in buildings.Part 3 : Ceilings.
pr EN 1364-4 1/97 A: : :
. 4: ().
Fire resistance tests on non-loadbearing elements.Part 3 : Curtain walling.
pr EN 1365-1 6/94 A: : :
.
1:E.
Fire resistance tests on loadbearing elements in buildings.Part 1 : Internal walls.
pr EN 1365-2 6/94 A: : :
. 2:E.
Fire resistance tests on loadbearing elements in buildings.
Part 2 : External walls.
pr EN 1365-3 11/93 A: : :
. 3:.
Fire resistance tests on loadbearing elements in buildings.Part 3 : Floor construction.
-
7/22/2019 ELOT
9/16
pr EN 1365-4 11/93 A: : :
. 4:.
Fire resistance tests on loadbearing elements in buildings.Part 4 : Roof constructions heated from the underside.
pr EN 1366-1 6/94 A: : :
. 1: ()
Fire resistance tests on service installations in buildings.Part 1 :Fire resisting ducts .
pr EN 1366-2 6/94 A: : :
. 2: ().
Fire resistance tests on service installations in buildings.Part 2 : Dampers.
pr EN 1366-3 11/93 A: : :
-. 3:.
Fire tests for building elements and components-Fire resistance testing of service installation.Part 3 : Penetration seals.
pr EN 1366-8 10/96 A: : :
. 8. ()
Fire resistance test for service installations in buildings.Part 8 : Smoke extraction ducts.
-
7/22/2019 ELOT
10/16
pr EN 1634-1 10/94 A: : :
() . 1:.
Fire testing of door and shutter assembliesPart 1 : Method of test for fire resistance of fire doors and shutters.
-
7/22/2019 ELOT
11/16
TC 191Fixed firefighting systems[ () ]
pr EN 615 6/94 A:
:
:
- - ( D ) .
Fire protection - Fire extinguishing media - Specifications for powders(other than class D powders).
EN 671-1 11/94 A: : :
-. 1: .
Fixed firefighting systems-Hose systems.Part 1 : Hose reels with semi-rigid hose.
EN 671-2 11/94 A: : :
-. 2: () .
Fixed firefighting systems-Hose systems.Part 2 : Hose systems with lay-flat hose.
EN 671-3 4/97 A: : :
-. 3: - () .
Fixed firefighting systems-Hose systems.Part 3 : Maintenance of hose reels with semi-rigid hose and hose systems with lay-flat hose.
pr EN 1028-1 2/93 A: : :
. 1: .
Fire fighting pumps.Part 1 : Requirements of fire fighting centrifugal pumps with primer.
-
7/22/2019 ELOT
12/16
pr EN 1028-2 2/93 A: : :
. 2: .
Fire fighting pumps.
Part 2 : esting of fire fighting centrifugal pumps with primer.
pr EN 1568-1 8/94 A: : :
- 1:
.
Fire extinguishing media - Foam concentratesPart 1 : Specification for medium expansion foam concetrates for top application to
water-immiscible liquids.
pr EN 1568-2 8/94 A: : :
- 2:
.
Fire extinguishing media - Foam concentratesPart 2 : Specification for high expansion foam concetrates for surface application to
water-immiscible liquids.
pr EN 1568-3 8/94 A: :
:
- 3:
.
Fire extinguishing media - Foam concentratesPart 3 : Specification for low expansion foam concetrates for surface application to
water-immiscible liquids.
pr EN 1568-4 8/94 A: : :
- 4:
.
Fire extinguishing media - Foam concentratesPart 4 : Specification for low expansion foam concetrates for surface application to
water-miscible liquids.
-
7/22/2019 ELOT
13/16
pr EN 12094-1 5/96 A: : :
- CO2. 1: A
.
Fixed firefighting systems - Components for CO2systems.Part 1 : Requirements and testing methods for electrical automatic control and delay
devices.
pr EN 12094-4 7/96 A: : :
- CO2. 4: ..
Fixed firefighting systems - Components for CO2systems.Part 4 :Requirements and test methods for high pressure container valve assemblies and their
actuators.
pr EN 12094-5 7/96 A: : :
- CO2. 5: .
Fixed firefighting systems - Components for CO2systems.Part 5 : Requirements and test methods for high and low pressure selector valves and their
actuators.
pr EN 12094-6 7/96 A: : :
- CO2. 6: .
Fixed firefighting systems - Components for CO2systems.Part 6 : Requirements and test methods for non-electrical disable devices.
pr EN 12094-7 7/96 A: : :- CO2. 7: .
Fixed firefighting systems - Components for CO2systems.Part 7 : Requirements and test methods for nozzles.
-
7/22/2019 ELOT
14/16
pr EN 12094-8 8/95 A: : :
- CO2. 8: .
Fixed firefighting systems - Components for CO2systems.
Part 8 : Specifications and testing methods for flexible connectors.
pr EN 12101-1 9/95 A: : :
. 1: - .
Smoke and heat control systems.Part 1 : Specifications for smoke curtains - Requirements and test methods.
pr EN 12101-2 9/95 A: : :
. 2: .
Smoke and heat control systems.Part 2 : Specifications for natural smoke and heat exhaust ventilators.
pr EN 12101-3 9/95 A: : :
.
3: .
Smoke and heat control systems.Part 3 : Specifications for powered smoke and heat exhaust ventilators.
pr EN 12416-1 5/96 A: : :
- . 1: .
Fixed firefighting systems - Powder systems.
Part 1 : Specifications and test methods for systems and components.
pr EN 12416-2 5/96 A: : :
- . 2: , .
Fixed firefighting systems - Powder systems.Part 2 : Design, construction and maintenance.
-
7/22/2019 ELOT
15/16
TC 192Fire service equipment( E )
pr EN 1147 9/93 A: : :
.
Portable ladders for fire service use.
pr EN 1777 12/94 A: : :
Y, () ..
Hydraulic platforms (HPs) for fire services.Safety requirements and testing.
pr EN 1846-1 2/95 A: : :
. 1: .
Firefighting and rescue service vehicles.Part 1 : Nomenclature and designation
pr EN 1846-2 8/96 A: : :
. 2: - .
Firefighting and rescue service vehicles.Part 2 : Common requirements - Safety and performance
pr EN 1924-1 2/95 A: : :M () .
Non-percolating layflat hoses for first aid hose installations.
pr EN 1924-2 5/95 A: : :
M () , .
Non-percolating layflat delivery hoses and hose assemblies for fire fighting purposes.
pr EN 1947 5/95 A: :
-
7/22/2019 ELOT
16/16
:
H-.
Semi-rigid reel hoses for firefighting pumps and vehicles.
pr EN ISO 14557 1/96 A: : :
(ISO/DIS 14557:1996).
Suction hoses for firefighting purposes (ISO/DIS 14557:1996).
pr EN 1028-1 2/93 A: : :
. 1: .
Fire fighting pumps.Part 1 : Requirements of fire fighting centrifugal pumps with primer.
pr EN 443 6/95 A: : :
.
Helmets for firefighters.