© 2011 Autodesk Converting Existing Piping Specs Ian Matthew Technical Marketing Manager, Autodesk.
-
Upload
tyrone-lamb -
Category
Documents
-
view
220 -
download
7
Transcript of © 2011 Autodesk Converting Existing Piping Specs Ian Matthew Technical Marketing Manager, Autodesk.
© 2011 Autodesk
Class Summary
In this class we will show you how to convert existing piping specs from Bentley’s AutoPLANT and from Intergraph’s CADWorx plant design systems so that they can be used in the AutoCAD Plant 3D plant design system.
We will tell you what problems to look for so that the conversion can be made quickly and effectively.
© 2011 Autodesk
Learning Objectives
At the end of this class, you will be able to: Convert an existing AutoPLANT piping spec to an AutoCAD Plant 3D spec Convert an existing CADWorx piping spec to an AutoCAD Plant 3D spec Understand how the AutoCAD Plant 3D Spec Editor works Identify common problems with converting piping specs
© 2011 Autodesk
Assumptions
1. You know what Piping Specs and Catalogs are!2. Familiar with Plant 3D Piping Specs and Catalogs structure and how they are
used3. Familiar with AutoPLANT or CADWorx Specs and Catalogs4. Familiar with AutoCAD Plant 3D Spec Editor
© 2011 Autodesk
Common Problems in Converting AutoPLANT Specs
Spaces in AutoPLANT Piping Spec Fields (instead of null) Missing Field Data Data in AutoPLANT Spec Field not transferred to Plant 3D AutoPLANT Classes not mapped to Plant 3D classes
© 2011 Autodesk
Problem 1 – spaces in blank fields
This shows in the “specname-log.txt” file as follows:
Correct by removing spaces in the appropriate classes
© 2011 Autodesk
Problem 2 – Missing Data
Again, the log file will indicate this:
Open the Spec database for the components named in the log. Fill in the missing data
© 2011 Autodesk
Problem 3 – Data not transferred
Field exists in AutoPLANT spec that does not exist in Plant 3D Or no mapping exists
Open AutoPLANT spec in Access and check fields
© 2011 Autodesk
Problem 4 – Missing Classes in Plant 3D
Classes are defined in AutoPLANT that do not exist in Plant 3D
Solution – create this class in Plant 3D:
© 2011 Autodesk
Process
Similar to AutoPLANT Spec Conversion Check for Class Mapping Check for missing fields Let the log file help you with the missing data
Tips: Make sure the output folder is EMPTY The log file is your FRIEND! Check Class mappings and Geometry mappings
© 2011 Autodesk
AutoCAD Plant 3D Spec Editor
Use it to modify and add to converted specs Easy to use Training available on Plant Exchange
© 2011 Autodesk
Converting Piping Specs
AutoPLANT or CADWorx Classes not mapped to Plant 3D classes Data in Spec Fields not transferred to Plant 3D Missing Field Data Spaces in AutoPLANT Piping Spec Fields (instead of null)
© 2011 Autodesk
What we did
Converted an AutoPLANT spec to Plant 3D Converted a CADWorx spec to Plant 3D Modified a spec using the Plant 3D Spec Editor Reviewed the common problems
© 2011 Autodesk
Converting Piping Specs
It’s EASY! No pre-conversion
The process is automated in AutoCAD Plant 3D Spec Editor Use the Log Files to help diagnose problems
Make sure the output folder is empty Or does not contain that spec partially converted
If you are changing SETTINGS – run as ADMINISTRATOR
© 2011 Autodesk
More Information
www.autodesk.com/plantexchange Video Tutorials Ask the Expert and Discussions Community of users
© 2011 Autodesk
Autodesk, AutoCAD* [*if/when mentioned in the pertinent material, followed by an alphabetical list of all other trademarks mentioned in the material] are registered trademarks or trademarks of Autodesk, Inc., and/or its subsidiaries and/or affiliates in the USA and/or other countries. All other brand names, product names, or trademarks belong to their respective holders. Autodesk reserves the right to alter product and services offerings, and specifications and pricing at any time without notice, and is not responsible for typographical or graphical errors that may appear in this document. © 2011 Autodesk, Inc. All rights reserved.