אאWא Electrocardiogram Machine (ECG)
אאWאאK
אאW אאאW
١. אאאאK
٢. אאK
٣. א
٤. א
٥. אאK
אאאWאאא٩٥K٪ אאW
J
J K
J אא
J אאK
J K
J K
J אK
אאW٦
אאWאאאאאK
א –١FE אא
٢٤٠ א
٢
W אECG machine)Eאאאאא
KאאאאאאKאאא אאאא
Electrocardiogram(ECG) אאאאאElectrodesאK
אאא
אאאאאא Wא
١. אאאRight Arm (RA)K ٢. אאאLeft Arm (LA) Right Leg (RL) אא .٣ Left Leg (LL)אא .٤ Chest (C)א .٥
אאLead SelectorK
אאRight Leg (RL) אLead SelectorאאאK
א –١FE אא
٢٤٠ א
٣
١١א
אאECGאאאאאFLead E
אאW
١. אאאBiopolar Limb Lead
I , Lead II , Lead III LeadאאאאאEinthoven Triangle
EאFאאLA אאא: (Lead I)אאKEאFאRAאאאא
אאאLL אא: (Lead II)אא
א –١FE אא
٢٤٠ א
٤
אאאRAאFELA RAK
אאאLL אא: (Lead III)אאאאאLAאFERL RAK
٢. אאאUnipolar Limb Lead
אAVRFLead AVR WEאאאRA אאאא
אLA אאLLאאK
AVLFLead AVL א WEאאאLA אאאאאRA אאLLאאK
LLאאAVFFLead AVF WEא אאאא
אRA אאאLA אאK ٣. אאאUnipolar Chest Lead
אאאאאV Leads ( V1 - V6 ) א אאאא
אאא FRA, LA, LL Eא resistor Wilson networkאאK
א –١FE אא
٢٤٠ א
٥
F٢١EאאאUnipolar Limb Lead
٣١אECG
אא،אאBlock Diagram אא٤EF١אKא
אECGK
א –١FE אא
٢٤٠ א
٦
F٤١EאאאK
א –١FE אא
٢٤٠ א
٧
אאW
WאאאW
١. אאאאאאאאW
٢. אאאאאאK
٣. אאאK
WאאאW
١. אאאאאאאאW
٢. אאאאאאK
٣. אאאK
א –١FE אא
٢٤٠ א
٨
Wאא
١. אאאאאאאאW
٢. אאאאאאK
٣. אאאK
אWאאאFאאE ١. אאאאאK
٢. א א אאא א אArtificial Patient) E א?א אא ? א א א
FאF٧١E
F٧١EאאאBiopolar Limb Lead
א –١FE אא
٢٤٠ א
٩
٣. א א א א א א אUnipolar Limb LeadFאF٨٢EK
AVRFLead AVR WEא
AVLFLead AVL WEא
AVFFLead AVF WEא
F٨١EאאאUnipolar Limb Lead
WאאאW
١. א אאא אOperation
ManualK
א?א א א א אא ? אא א 1 mv א א Kאא
٢. אאאא אא ،אFjellKEאא
א –١FE אא
٢٤٠ א
١٠
٣. אאאאאאאK
٤. אאאאאאא אא א א אא א
FLead selectorEKא
אא .٥
אW
אאאאאW ١. HRZ١٥٠٠אאאRK ٢. HRZ٦٠אאRK ٦. אאאWP, R, T
٧. אאWP, QRS, ST, T
٨. אאאאאאאאאאK
אא
––١١
א
٢
א –١FE אא
٢٤٠ א
١١
אWא
אאWאאK
אאW אאאW
١. א
٢. א
אאאWאאא٩٠K٪
אאW J
J K
J אא
J אאK
J אK
J אK
J אK
אאW
אאW
אאאK
א –١FE אא
٢٤٠ א
١٢
אאאאSA node
Kאאאאאא א،אאאא١٩٠١א
אאא،אאאאK
א א F١٢ E א א א K א א אאא
SAK
F١٢Eאא
١٢אא Pacemaker אW
١- Wאאאאאאא א אא אא א
א –١FE אא
٢٤٠ א
١٣
אאאאאSAK
٢- אאWאאא،אאאK
F٢٢Eא
٢٢אBattery אאאאאK
אאא٢٥אF25 μJEאאאאאאא
١٥٣٠٠ K א ?א lithiumiodine?W
١( אאא٨٢Open Circuit Voltage: 2.8 Volt
٢( אא٢٢אControl Circuit minimal voltage: 2.2 Volt
א –١FE אא
٢٤٠ א
١٤
٣( א١٠אאControl Circuit current drain: 10 μA ٤( אא١٠אEOL battery resistance: 10 k Ohms
٥( א٥١٥ Discharge times: 1 ms, 5 ms
٦( אאא Reliability: 99.6% probability of
survival beyond 10 years ٧( אWאאאF٣٢E
٥١٢א٥١٥אweight of a lithiumiodine battery 12.5 to 15.5
grams ٥א٨אvolume: 5 to 8 cc
٣٢אא
א
א אא٤٢ א א אא Kא٥١٥ F515 Ω EאאאK
א –١FE אא
٢٤٠ א
١٥
٤٢אאאsimplest pacemaker circuit.
אאאאאK
אאאאאאאאאW
٥٢אאא
Current flows from the battery to charge the capacitor
א –١FE אא
٢٤٠ א
١٦
א א א א K אא אא(steady state)אא א
אFאEאא٦٢K
٦٢אאFאE
٧٢
אאא K אא
א –١FE אא
٢٤٠ א
١٧
אאאאK
אאאאא٢٠F20 KΩEאא?KאאאאאK?
אאאאאאאא١٠אF10 μFEאאKאאאK
Wאאאאאא
٨٢אאאאא
אאאאאאKאאאK
٣٢אא ١. אאאא
٢. אא
٣. אאאא
٤. אאאF٣E
١٨
אא
––١١
א
٣
א –١FE אא
٢٤٠ א
١٨
אWאDefibrillator
אאWאאK
אאW אאאW
١. אK
٢. אK
٣. אK
אאאWאאא٩٥K٪
אאW J
J K
J אא
J אאK
J אK
J K
J אK
אאW
אאW
אאאK
א –١FE אא
٢٤٠ א
١٩
F١٣EאFאאEDefibrillator
אFאאEDefibrillatorF١٣Eא
אKאאאאאאאאאאא
Cardiac ArrhythmiasאאאאKאאאאK
١٣אW
אאאPaddles אK א א אא
،אK אאאאCapacitor
אאא، א،א א אאא א א א אאאKאא
F٢٣KE
א –١FE אא
٢٤٠ א
٢٠
F٢٣Eאאאאא
אאאאא50 300 Wאא
( 1 )
2V.C 2
E אאאW
( 2 ) 2
2
V
EC
W EWאאא( Joul ) א( Watt - Second ) CWאCapacitance אא( F ) K V Wאאא( V ) K
FEאאDefibrillator Analyzer
א א אאאKא٥٠אאK
אאW
א –١FE אא
٢٤٠ א
٢١
אאK אK אK אK אאK
F٣٣EFEאאDefibrillator Analyzer
אאאאאW
אאאW ١. אאאK ٢. אאאאK ٣. אאאאK ٤. אאK
א –١FE אא
٢٤٠ א
٢٢
٢٣אאW ١. א א א א א Operation
ManualK
٢. א
٣. אאאאdefibrillation mode
٤. אא٢٠א
٥. אאאאאFאE
٦. אא
٧. א א אא אאאאאא
٨. אא٤٧א٥٠א،١٠٠،١٥٠،٢٠٠،٢٥٠
٩. אא٢א
١٠. אאאFEאאא
٢٣
אאאא
––١١
אא
٤
א –١FE אאא
٢٤٠ אא
٢٣
אאWאא
אאWאאאK
אאW אאאW
١. אא
٢. אא
٣. אא
אאאWאאא٩٠K٪
אאW J
J K
J אא
J K
J K
אאW
אאW
אאאK
א –١FE אאא
٢٤٠ אא
٢٤
W אאאאאאא
rπ٢ WאאאאאאאK T WאאאאאאK א (f= 1 /T) אf אאאאא
אאאK 2 .
T
f
T
1
f 2
2mrF א א א א אאאא א א
אאאאאאKאאאK
١٤אאאW
אאאאאאאFEאKאאאאאאאא
١. (on/off switch)
٢. FMotorEאאאא ٣. (Timer) אאא א
א ١EHead & sample holderF٤אא .٤
א –١FE אאא
٢٤٠ אא
٢٥
F١٤Eאא
א .٥ א(Cover)אאאאא
אא
٦. אא(Speed Control Switch)אאא
אאאאאאא(Breaker)א .٧אאאK
W KאאאF٦EF٧Eאא
א –١FE אאא
٢٤٠ אא
٢٦
F٢٤E
٢٤אאW ١. א א א א א Operation
ManualK
٢. א?אאאאאא?
٣. א
٤. אאאF١٠E
٥. אאא
٦. אאאW
٧. אאא٤K ٨. אאא٤K
Kאאא .٩
١٠. אאאאא Technical Manual Kא
٢٧
אא
––١١
א
٥
א –١FE אא
٢٤٠ א
٢٧
אWאBlood Pressure Monitor
KאאWאא
Wאא אאאW
١. א ٢. אא
٣. אא
אאאWאאא٩٠K٪
אאW
J
J K
J אא
J K
J K
J אK
Wאא
אאW
אאאK
א –١FE אא
٢٤٠ א
٢٨
١٥אאW
אאWאאאאW
א א Systolic PressureW א א א א אאא?אאK?
אא١١٠א١٣٠Fmm HgE אא Diastolic PressureWאאאאאא
אאאאא אKF٧٠٨٠mm HgKE אאאאאאK
FEאאאאW אFZאאHאאED٢
א –١FE אא
٢٤٠ א
٢٩
F٢٥EאאאאWאא،אאאK
F٢٥Eא
א –١FE אא
٢٤٠ א
٣٠
٢٥אאאW
F٣٥Eאאא
١. אאMain BodyK
٢. אDisplayK
٣. אאAir ConnectorK
٤. אTube PlugK
٥. אאAir HoseK
٦. אFאECuff ٧. אאאAC Power Connector K
٨. אאאAC Power Adaptor
٩. אאMemory BottonK
FאאאEאאא K א K ٣٠
א –١FE אא
٢٤٠ א
٣١
אאאK
١٠. אאButton١0/K
אאW אא א א Kא א
אא אא א אא אא אK א א א אא
K ١. אאאW
אאאא - أא א Kאא
אאאאאאK
- ب א א א א K א א
א K א א אאK
٢. אW א5אאא - أ
אאאאK
א –١FE אא
٢٤٠ א
٣٢
אאאאא - بא אא א
אאאא א א
א10-5אK
א - ت א אא אא3-2אKא
א א ? ? אאK
- ث אא אא K א אא
אאאאKאאא א א א
אאאK
אאW ١. אאאא3-5F JEאK
אאK
א –١FE אא
٢٤٠ א
٣٣
٢. א אא 2-1 Kא אא א א אאאאאאK
٣. א א אא א א א אא K א ،
190K
٤. א190،אאאאKאאKא♥ "?אKאאא
א،אאאאא،אK
٥. ،אאאאאאאאאאK
٦. אאאKאאאאאKאאאא،א
אאK
٣٥אאW
١. אאאאאאF٤٥EאW
F٤٥Eאאא
א –١FE אא
٢٤٠ א
٣٤
Kאאאאא .٢
٣. אאאאא
٣Kאאאאא .٤
٥. א אא אא אאאK
٦. אאאאאK
٧. אאא
٣٥
אא
––١١
א
٦
א –١FE אא
٢٤٠ א
٣٥
אWאMicroscope
אאWאאK
אאW אאאW
١. אK
٢. א
٣. אאאאK
אאאWאאא٩٠K٪
אאW J
J K
J אא
J K
אאW
אאW
אאאK
א –١FE אא
٢٤٠ א
٣٦
אאWא،א،אK
אאאאFאאאμmKE
אאאאאאאאאאאאאFאE
MicroscopeK
Light Microscopes ١٦אאW
אאאאאW J J J א א K א א א
אאאאK JאאאאK JאFDiaphragmEאאא Kאא
אאK JאWא א א K א
אFאEאK JאאFobjectivesEאFKEא
אאX4Kאאx100K JאאFOcularE–אאFאEאK
אאאאאאK JאFאWE
FfocusEWאאאאאאK
J : אאאאאאאK
א –١FE אא
٢٤٠ א
٣٧
١٦אא
א –١FE אא
٢٤٠ א
٣٨
٢٦אאW
אאאאאK אאאאW
١–אאאאאאאK
٢–אK ٣–א١٥אאאא،K ٤–אאאאאאא
אK ٥–אאאאאK
WאאאW
אאאאאאאW٤C،١٠٠CK
א٤CW
١. K ٢. אK ٣. אאאאאK ٤. א٤אCאאא
אאK ٥. אאאאK
א١٠٠C
אאאאאK
א –١FE אא
٢٤٠ א
٣٩
١. אF٣٦EHaemocytometerאאאK ٢. אא٤CK ٣. ١٠CאאאאאK ٤. ٤٠אCאאאאאK ٥. ١٠٠אC،אאאאא
אאK
אW
אאKאאFאKEאאאא،אK
אאW
١. אFאEאאFEK
٢. אאא،אאאאאאK
٣. אאאאא،אFאEאK ٤. אK
א אא אא
٤C
١٠٠C
א –١FE אא
٢٤٠ א
٤٠
F٣٦E
٤١
אאאא
––١١
אא
٧
א –١FE אא
٢٤٠ אא
٤١
אWאא Thermometer
אאWאאא K
אאW אאאW
١. אאאK ٢. אאאK
٣. אK
אאאWאאא٩٥K٪
אאW J
J K
J אא
J אK
J אK
J אK
אאW
אאW
אאאK
א –١FE אא
٢٤٠ אא
٤٢
א א אא א א א
אאאאאאאKאא א א א אא א א אא
אאאאאאאK
١٧אאאאW
אאאאאאאK א אא אא א
אKאאאאאFTransducerE
אאאאאאאאאW
١EאאאאFRTDEW אאאאאאאK
א Positive temperature coefficient (PTC) אאאאאאאא.Resistance temperature Detector (RTD)
א א RTD א אאאאאאF١٧E
א –١FE אא
٢٤٠ אא
٤٣
F١٧EאאאאאאאאRTD
٢EאאאFאEThermistorW אאא
אאאא Negative temperature coefficient (NTC) אאאאאא
אאאאא3542אKאאאאאאK
אאאאאאK אאאאאאאאא
אF٢٧E
F٢٧Eאאאאאאאא
א –١FE אא
٢٤٠ אא
٤٤
٣EאאאThermocoupleW
אאאאK אאאאא
אאאFאKE א אא א א אאא אא
אאF٣٧E
F٣٧Eאאאאאאאאאא
٣٩אאאW
١. אא א אBalance F א Eא
٢. אאאRTDK
٣. אאאא א א אאאאK
٤. א٢٣אאאRTDאא
٥. א٢٣אאK
٦. אא؟
٤٥
אא
––١١
א
٨
א –١FE אא
٢٤٠ א
٤٥
אWאElectromyography
אאWאאK
אאW אאאW
١. אאאEMG
٢. א
٣. א
٤. א
אאאWאאא٩٠K٪
אאW J
J K
J אא
J K
J K
אאW
אאW
אאאאאK
א –١FE אא
٢٤٠ א
٤٦
אElectromyography(EMG)אאאאאאאKאאאא
אאKאא(EMG) אא(Surface
Electrodes)אאאאאאK
אא،אאאאאאאא
א אאאאאאK
١٨אW ١. א5א mVאא
אאKאאאא١٠٥٠٠.Hz
אאאאאKאאאאא
אאאKאאF١١٠EאאאאW
١٨אאאא
١. אW،אFEKאאאאאאאא
אאF٢٨אKE
א –١FE אא
٢٤٠ א
٤٧
F٢٨EאEMG
F٤١٠EאEMG
٢. אאW
אאאאאאאאKאEMGאא
א5mV10mvK٥٠٠FAcl=500E
٣. אW אאאאא
א
א –١FE אא
٢٤٠ א
٤٨
אאאF٤٨Eאאאאאא٥٠٠אאKא
W
5007.4
471
10
47
10
4421
clA
א48 nF א٣٣ MΩאאא١٠Hzא٨٦ nF א٤٧ KΩ אאא
٥٠٠HzKאאאW
RCfc 2
1
F٥٨EאאאאאEMG
א –١FE אא
٢٤٠ א
٤٩
٤. אW אאאאאK
אאאאאKאSampling frequency(fs)fs=1000HzאאA\D Analog to digital converterKא
אאאאאאאאאאspectral analysisKא
אאF٥٨E
F٥٨Eא
א –١FE אא
٢٤٠ א
٥٠
٢٨אאW ١. א א א א
אK
٢. אאאK
٣. א א א א אOperation ManualK
٤. א٥٠٠K
٥. אאאאF٦٨FEאאא E א א א Fא א
،אאאאאאEאאK
F٦٨Eאא
٦. W
٣٠Kאאאא - أ ٣٠Kאאאא - ب
٧. אאאא אאאאK
٨. אאאאא
٥١
אא
––١١
א
٩
א –١FE אא
٢٤٠ א
٥١
אWאInfusion Pump
אאWאא
Wאא אאאW
١. אא
٢. אא
אאאWאאא٩٠K٪
אאW
J
J K
J אא
J K
J K
J א
אאWK
אאW
אאאK
א –١FE אא
٢٤٠ א
٥٢
W אאאאK
אאאאאאאאאאאKאאאא
אאאאאאאIntravenous ( IV )K
אאאאאאאאאא،א
אאאאאאאאאאאאאאאK
١٩אאאאW
١٩אאאא:
١( Handle ٢( אאComplete Alarm
٣( אBubble Alarm
א –١FE אא
٢٤٠ א
٥٣
٤( אאא Occlusion Alarm
٥( אא Door Open Alarm
٦( א LOW BATT Alarm
٧( Select
٨( אאא Build-In Battery Indicator
٩( AC Power Indicator
١٠( אLאStart/Stop
١١( אPurge Key
١٢( א Infusion Indicator
١٣( Number Key
١٤( Number Key
١٥( Door Latch
١٦( אDosage limitation Display
١٧( אFlow Rate
١٨( אאVolume Delivered
١٩( אBubble Detecting System
٢٠( אTube Clamp
٢١( Dose Calibration Switch
٢٢( אTube Pincher
٢٣( אTube Retainer
٢٤( אPincher-Close Button
٢٥( אTube Guiding Post
٢٦( אFlow Detecting System
٢٧( א Alarm Signal Output
٢٨( אאON/OFF Switch
٢٩( ١٢DC 12V Socket
٣٠( ٢٢٠AC 220V Socket
א –١FE אא
٢٤٠ א
٥٤
٢٩אאW
١( אא ٢( אא٢٢٠אאאאאא
١٠K ٣( אאא
٤( אאאאאא
٥( אאK
٦( א،אאאאאאאFאאEא
אK
٧( אאאאא
(0000)אא1ml/h א50 mlאאK
٨( אא٥٠٠ml/h אאאאא١٠٠mlK
א –١FE אא
٢٤٠ א
٥٥
٩( אאא
١٠( אאאאאK
١١( אא
١٢( אא٥אאאW
אZאLא ١٣( אאאאאאא
١٤( אאF٨١٣EאF٨٠٠ml/hEF١٠٠٠ml/hE
١٥( אאאאאאTechnical Manual K
- ٥٦ -
אאאא
––١١
א
א
١٠
א –١FE אא
٢٤٠ אא
٥٦
אWאא Spectrophotometer
אאWאאא
אאW אאאW
١. אא
٢. אא
٣. אא
אאאWאאא٩٠K٪
אאW J
J K
J אא
J K
J K
J
אאW
אאW
אאאK
א –١FE אא
٢٤٠ אא
٥٧
W אאאאא
אאאאאאאאאאאאאא
אKאאאאאאאאאאKאאא
SpectrofotometerאאאאאאאאאאאK
١١٠אאSpectrophotometer
אאF١٠١EאאאאW
١- אאLight Source Wאא٣٣٠ J١٠٠٠nmK
٢- אMonochromatorWאאאא λmaxאK
٣- Sample compartment Wאאאאאא
٤- אdetectorWאאאK
٥- אאMicroprocessorWאאאאאאK
٦- אDisplayWא،א،אK
א –١FE אא
٢٤٠ אא
٥٨
F١١٠Eאאאא
אW
F٢١٠Eא
١. אSample compartmentWאאאK
٢. אWAVELENGTH CONTROLWאאK
٣. אPOWER ON/OFF INDICATORWאK
٤. אLCD LIGITAL READOUTWאאLEDאאאאFא،
א،א،אE
א –١FE אא
٢٤٠ אא
٥٩
٥. אאMODE SELECTOR KEYWאאFא،א،א،אKE
٦. אL١٠٠٪100%T/OA CONTROL KEYWא١٠٠٪KאאאK
٧. 0%T CONTROL KEYWאK
٨. אWאאאאK
٩. אאCONCENTRATION/FACTOR KEYSWאאאאאK
١٠. אא WAVELENGTH READOUT WINDOWFWאEאFwavelength scale?Eא
K
אאאW
١. אK
٢. א١٥K
٣. אא٩٥٦٧אאא٥٦٨K
٤. אאאא،א،אא Kא
٥. אאF١٠،אא٣٢٠KE
٦. אאFאא٢٠KE
٧. אאאאאאא
٨. אאאאL١٠٠٪א100.0%אT or 0.000AK
א –١FE אא
٢٤٠ אא
٦٠
٩. אאאאאK
١٠. אאאאאK
١١. אאאK
١٢. אא١٠١١K
١٣. אאאא אTechnical Manual אK
F٣١٠EאאFאאFSpectrophotometerE
א –١FE אא
٢٤٠
אא
אאא
١Kא Kא
٢Kאא Kא
٣Kאא Kאאאא
אאא
1. Introduction to Biomedical Engineering Technology Carr Brown 2. Medical Instrumentation Application and Design John
Webster 3. Medical Instrumentation and Measurements
א –١FE א
٢٤٠
א
א א
אאWא
אאWא אאWא אאאWאא
אאWא
אאWא
אאWאא אאWא
אאWא
אאWאא