University guest house for visiting FINAL

Post on 21-Jan-2017

110 views 1 download

Transcript of University guest house for visiting FINAL

University guest house for visiting professors

SalzburgDarya Haroshka

Johannes SeeberAntoine El BitarIlgar Manafsoy

1

Final Presentation1

Design - requirements

Sustainable and energy efficient university building

1.Work: 10 office; meeting+presentation room; storage2.Home: 10 living units with bath, kitchen, bedroom and living room;3.Communication: foyer; exhibition room; club lounge; multipurpose hall4.Infrastructure: management; technology center; administration;Approx. 1200m²

22

LocationSalzburg, Austria

cold, continental climate

33

Design ConceptKISSPassive House components- Insulation- Triple glazed windows- Airtightness- Compactness- Mechanical ventilation with heat recoveryPV-system on the roofBore hole heat exchangerWinter garden/Thermal massNatural ventilation by nightGreen facade

44

LocationSalzburg, Austria

54

Urban Design

Location on the sideOrientationConsidering the height of surrounded buildingsView to/from castle

66

Ground floor

77

1st floor

88

2nd floor

99

roof

1010

section

1111

section

1212

facades

1313

Living units

1414

Living units

1515

Area and volume

1616

Ground floor:-574m² GFA-495m² NFA-1485m³ Volume1st floor:- 430m² GFA- 342m² NFA- 890m³ Volume2nd floor: - 430m² GFA - 342m² NFA - 890m³ Volume

TOTAL AREA:- 1430m² GFA- 1180m² NFA- 3265m³ Volume

Energy strategyPASSIVE STRATEGYInsulationTriple glazed windows/DoorsAirtightnessCompactnessMechanical heat recovery ventilationPassive solar useInternal heat gainsSelf shading facadeThermal massNatural Ventilation by night

ACTIVE STRATEGYPhotovoltaic for electricityBore hole heat exchangerSolar thermal collectors 1717

Passive strategies

1818

Passive House components- Insulation- Triple glazed windows- Airtightness- Compactness- Mechanical ventilation with heat recoveryPassive Solar useWinter garden/Thermal massNatural ventilation by nightGreen facade

Construction elements

1919

Outside wall, u-value 0,127 W/m²K

Construction elements

2020

Inside wall wintergarden, u-value 0,127 W/m²K

Construction elements

2121

roof, u-value 0,142 W/m²K

Construction elements

2222

Slap floor, u-value 0,141 W/m²K

Airtightness

2323

Winter garden

2424

Winter garden

2525

Winter garden

2626

Winter garden

2727

Winter garden

2828

Natural ventilation by night

2929

Green facade

3030

2 types of green facade - Grüne Wand - Fassadengarten

Green facade

3131

Active strategies

3232

PV-system for Mechanical Ventilation, heat pump and lightsBore hole heat exchangerSolar thermal collectors

PV- system on the roof

3333

-Approx. 3700 kWh for mechanical Ventilation(dark grey) = 12 PV-modules- approx. 6600 kWh for heat pump(medium grey) = 21 PV-modules- 33 free PV-modules for lighting/electricity(light grey)

Bore hole heat exchanger

3434

Bore hole heat exchanger with heat pump- The heat pump provides 37°C hot water which can be used for heating purposes. 10additional heating devices are placed in the showers to heat up the water to around 60°C.- In the summer the cold water is used for offices area activation for cooling- 3 drillings deliver 15kW for heating

Energy balance

3535

NORTHEASTSOUTHWESTHORIZONTAL

Energy balance

3636

Energy balance

3737

Energy balance

3838

3939

4040

4141

4242

4343

4444