Uji Model HidraulikBendung Sei Silau

Gambaran Umum

Sandtrap

Intake

Bendung

Saluran

Sungai Silau

Layout Model

Denah Bendung

(ukuran model, dalam cm)

65 m75 m

(ukuran prototipe, dalam m)

Skala Model

PROTOTIPE Tak ter-distorsi

terdistorsi

• Euler Number (𝐸 =𝑉

∆𝑃𝜌

) Dominated by pressure difference

• Froude number (𝐹𝑟 =𝑉

𝑔𝐿) Dominated by gravity

• Reynolds number (𝑅𝑒 =𝑉𝐿

𝑣) Dominated by viscosity

• Mach number (𝑀𝑎 =𝑉

𝐸 𝑃

) Dominated by density

• Weber number (𝑊𝑒 =𝑉

𝜎 𝜌𝐿

) Dominated by surface tension

Angka tak berdimensi

X

Y

Z

x

y

z

xy

z

Skala Model

Froude number (𝐹𝑟 =𝑉

𝑔𝐿)

Parameter Notasi Skala

Panjang nL nL 30

Kedalaman nL nL 30

Area nA nL2 900

Volume nV nL3 27000

Waktu nT nL0.5 5,48

Kecepatan nU nL0.5 5,48

Debit nQ nL2.5 4929,50

(Satuan SI)

Pembuatan Model

22 m

10 m

Domain model dan layout penempatan model

Sarana Pendukung Model

Reservoir (dan pompa pd reservoir utama)

Persiapan Lahan dan Pembuatan Grid Lapangan

Pembuatan Tampang Lintang

Pembuatan Tampang Lintang

Kontrol Elevasi Dasar Saluran

Pembuatan Model Mercu Bendung

Pembuatan Bangunan Pelengkap Bendung

Penyiapan tempat perletakanmodel bangunan pelengkap

Pembuatan model denganacrylic (dibuat indoor)

Pembuatan Bangunan Pelengkap Bendung

Pembuatan Bangunan Pelengkap Bendung

Pembuatan Bangunan Penangkap Pasir

Finishing

Model dibersihkan

Pengecatan, danpengecekan

kelengkapan instrument model (alat ukur, dsb)

Uji Model

Boundary Condition

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.45

0 100 200 300

Tin

ggi

muka

air,

h(m

)

Debit, Q (l/s)

QT

Discharge(m3/s)

US waterlevel(+mMSL)

DS waterlevel(+mMSL)

Qn 23,26

Q½2 55,79

Q2 111,59 36,48 34,91

Q10 345,54 37,52 36,6

Q20 474,19 38,06 37,23

Q50 675,49 38,73 38,12Q100 853,98 39,7 38,86

Alat Ukur Kedalaman dan Kecepatan Aliran

Alat Ukur Tinggi Tekanan

Pressure head, y

contoh

Pengukuran Debit

Uji Hidraulika Model

Uji Hidraulika Model

Uji Performa Sandtrap

Uji Performa Sandtrap

Daerah

terbilas

13,13%

Uji Performa Sandtrap

(dua pintu dibuka)

Uji Performa Sandtrap

(satu pintu dibuka)

P1 P2

Daerah

terbilas

24 %

Daerah

terbilas

P2

Uji Performa Sandtrap

(satu pintu dibuka)

19,88 %

Uji Hidraulika Model

Model Test (Q2)

23/11/2015 Model Hidraulik Bendung Sei Silau 32

30.00

35.00

40.00

45.00

0 100 200 300 400 500 600

Ele

vas

i m

uka

air

pro

toti

pe

(+m

MS

L)

Jarak (m)

Dasar Q2th Tanggul

Uji Hidraulika Model

Model Test (Q10)

23/11/2015 Model Hidraulik Bendung Sei Silau 34

30.00

35.00

40.00

45.00

0 100 200 300 400 500 600

Ele

vas

i m

uka

air

pro

toti

pe

(+m

MS

L)

Jarak (m)

Dasar Q10th Tanggul

Uji Hidraulika Model

Model Test (Q50)

23/11/2015 Model Hidraulik Bendung Sei Silau 36

30.00

35.00

40.00

45.00

0 100 200 300 400 500 600

Ele

vas

i m

uka

air

pro

toti

pe

(+m

MS

L)

Jarak (m)

Dasar Q50th Tanggul

Uji Hidraulika Model

Model Test (Q100)

23/11/2015 Model Hidraulik Bendung Sei Silau 38

30.00

35.00

40.00

45.00

0 100 200 300 400 500 600

Ele

vas

i m

uka

air

pro

toti

pe

(+m

MS

L)

Jarak (m)

Dasar Q100th Tanggul

Flood water level is sufficiently below the dike

Sayap pengarah

aliran tambahan

Modifikasi

debit intake meningkat

• Flood water level is sufficiently below the dike

• Submerged flow occurred while Q20, Q50 dan Q100 was applied

• The shape of weir wasn’t ideal due to ogee

• Discharge coefficient was deviated while Q20 and Q50 was applied

• Ideal hydraulic jump didn’t occurred because of the downstream effects

• End sill design affect the secondary jump occurrences

• Stilling basin didn’t effective in dissipating energy

• The result of intake discharge test in original design is 6,68 m3/s.

• The maximum intake discharge reached on two full-opened gates.

• The discharge using guide wall with dimension on model scale 0,46 m × 0,09 m ×0,47 m could be raised.

• Flushing velocity on model test is only 45% of designed velocity.

• Vertical contraction in upstream settling basin structure have a good effect of sediment flushing.

Conclusions