Trial Configuration 12-12-12-8 Flexi EDGE_final

Post on 09-Mar-2015

130 views 1 download

Transcript of Trial Configuration 12-12-12-8 Flexi EDGE_final

Soc Classification level 1 © Nokia Siemens Networks

TTrial :rial :

Configuration 12/12/12/8 Flexi EDGEConfiguration 12/12/12/8 Flexi EDGETest bed, 19 May 2010Test bed, 19 May 2010

Soc Classification level 2 © Nokia Siemens Networks

Trial team

Team

TI :

1. Bagas

2. Reyhantino

3. Suherman

4. Noor M.

5. Poetra

6. Ari Guro Chandra P.

NPO (Special Project):

1. Ferdinandus Ruruk

BSC Eng :

1. Ipan Pribadi

2. Edi Supriadi

BTS ENg :

1. Wisnu

Soc Classification level 3 © Nokia Siemens Networks

List of content

• Purpose

• List of modules

• Cabling Diagram

• Module stack

• Module stack for Outdoor (FCOA)

• Module stack for Indoor (FCIA)

• Abis scheme

• Frequency Plan

• Test Call result

• Alarm Capture

• TRX Configuration

• Test Edge

• Summary

Soc Classification level 4 © Nokia Siemens Networks

Purpose

• To test high capacity configuration with new mobile allocation list frequency scheme in SFH system

• To increase availability high capacity expansion

• New Mapping timeslot in Abis interface

Soc Classification level 5 © Nokia Siemens Networks

List of Module

Modul Required for 12/12/12/8:

No Name of Module Ouantity Description

1 ESMA EDGE 2 System Module

2 FIPA 2 Interface PDH E1/T1/JT1

3 ESEA 2 Flexi EDGE Extension Module

4 ERxA 11 FLEXI Edge RF Dual Duplexer 1800

5 EXxa 22 FLEXI Edge 1800 DTRX UNIT

6 EWDB 22 FLEXI EDGE 1800 WBC SUB MOD

7 ESFA 1 SYNC CABLE FOR FLEXI 12M

8 FTCB 8 OD CABLE RJ48C 120ohm 15M

9 Jumper Indoor 22

10 Antenna 11

Soc Classification level 6 © Nokia Siemens Networks

Cabling Diagram 1 of 3 (RF cabling)

• 12 TRX

Tx

Rx

TxA RxA RxA Div RxB RxB Div TxB

TxA ExtA RxAO RxAI RxA1 RxA2 RxA3 RxA4 RxB1 RxB2 RxB3 RxB4 ExtB Tx B

TxA RxA RxA Div RxB RxB Div TxB

TxA ExtA RxAO RxAI RxA1 RxA2 RxA3 RxA4 RxB1 RxB2 RxB3 RxB4 ExtB Tx B

TxA RxA RxA Div RxB RxB Div TxB

TxA ExtA RxAO RxAI RxA1 RxA2 RxA3 RxA4 RxB1 RxB2 RxB3 RxB4 ExtB Tx B

TxA RxA RxA Div RxB RxB Div TxB

TxA RxA RxA Div RxB RxB Div TxB

Soc Classification level 7 © Nokia Siemens Networks

Cabling Diagram 2 of 3 (RF Cabling)• 8 TRX

Tx

Rx

12/12/12/8 configuration use 2x 12 trx for first module system and 1x 12 trx plus 8 trx in the second module system.

TxA RxA RxA Div RxB RxB Div TxB

TxA ExtA RxAO RxAI RxA1 RxA2 RxA3 RxA4 RxB1 RxB2 RxB3 RxB4 ExtB Tx B

TxA RxA RxA Div RxB RxB Div TxB

TxA ExtA RxAO RxAI RxA1 RxA2 RxA3 RxA4 RxB1 RxB2 RxB3 RxB4 ExtB Tx B

TxA RxA RxA Div RxB RxB Div TxB

TxA RxA RxA Div RxB RxB Div TxB

Soc Classification level 8 © Nokia Siemens Networks

Cabling Diagram 3 of 3 (Power,BUS and IF cabling)

12/12 -> 24 Trx 12/8 -> 20 Trx

System#1 System#2

ESEA 1

ESMA 1

ESEA 2

ESMA 2

IF1 to ET#1

IF2 to ET#2IF3 to ET#3

IF1 to ET#4

IF2 to ET#5

IF4 system#1 to IF3 system#2

PWR10 PWR11 PWR12 PWR7 PWR8 PWR9

BUS

PWR10 PWR11 PWR12 PWR7 PWR8 PWR9

BUS

Sync Cable

Soc Classification level 9 © Nokia Siemens Networks

Modules Stack

12/12 -> 24 Trx 12/8 -> 20 Trx

System#1 System#2

12 Trx

12 Trx

ESEA 1

ESMA 1

12 Trx

8 Trx

ESEA 2

ESMA 2

Sync Cable

Soc Classification level 10 © Nokia Siemens Networks Presentation / Author / Date

Modules Stack

ESMA

ESEA

ESMA

ESEA

12 Trx

12 Trx

8 Trx

12 Trx

BUS cabling

For Outdoor with FCOA

Soc Classification level 11 © Nokia Siemens Networks Presentation / Author / Date

Modules StackFor Indoor with FCIA

ESMA

ESEA

ESMA

ESEA

12 Trx

12 Trx

8 Trx

12 Trx

BUS cabling

Soc Classification level 12 © Nokia Siemens Networks

Abis scheme

• This configuration used 5E1,

3E1 for System#1 (BCF 1), and 2E1 for System#2 (BCF 2).

Microsoft Office Excel 97-2003 Worksheet

Soc Classification level 13 © Nokia Siemens Networks

Frequency PlanMacro Frequency MALIST

Frequency Allocation

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Sector 1 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807

Sector 2 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828

Sector 3 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610

Sector 4 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595

SFH 1X3

7 7 21 8 8 8 21 21 6

574 575-581 583-589 590-610 687-694 695-702 703-710 787-807 808-828 829 830-835 836

BCCH-1BCCH-2BCCH-3TCH-1TCH-2TCH-3BCCHTCH-1TCH-2

37 channels 24 channels 48 channels

MACRO

MICRO

Soc Classification level 14 © Nokia Siemens Networks

Test Call Result

Sector 1 _ BTS 881 _ ARFN 700

Based on call test, all TRXs can be occupied by traffic. Picture below represents TRX1 in sec 1.

Microsoft Office Word 2007 Document

Soc Classification level 15 © Nokia Siemens Networks

Alarm capture

No Alarm found on each BTS

Soc Classification level 16 © Nokia Siemens Networks

TRX Configuration

SFH Sec 1

BCCH Sec 1

MALIST Sec 1

Sector I

Soc Classification level 17 © Nokia Siemens Networks

TRX Configuration

SFH Sec 2

BCCH Sec 2

MALIST Sec 2

Sector II

Soc Classification level 18 © Nokia Siemens Networks

TRX Configuration

SFH Sec 3

MALIST Sec 3

BCCH Sec 3

Sector III

Soc Classification level 19 © Nokia Siemens Networks

TRX Configuration

BCCH Sec 3

SFH Sec 4

BCCH Sec 4

MALIST Sec 4

Sector IV

Soc Classification level 20 © Nokia Siemens Networks

Edge Test

Sector I

Code scheme Sec 1

BCCH sector 1

Bcch sector I : 689

Soc Classification level 21 © Nokia Siemens Networks

Edge Test

Sector II

Code scheme Sec 2

Bcch sector II : 698

Throughput average Sec 2

Soc Classification level 22 © Nokia Siemens Networks

Edge TestSector III

Code scheme Sec 3

Bcch sector III: 705

Throughput average Sec 3

BCCH Sec 3

Soc Classification level 23 © Nokia Siemens Networks

Edge TestSector IV

Code scheme Sec 4

BCCH sector IV : 833

Throughput average Sec 4

BCCH Sec 4

Soc Classification level 24 © Nokia Siemens Networks

Summary

• Availability Capacity expansion depends on frequency license of service provider own

• Mobile Allocation List (MALIST) Frequency in SFH system refer to hopping range determined by ETSI

• TRX Edge enabled per BCF

• One BCF could handle maximum 24 TRX

• TRXSIG allocation dedicate for each TRX in Abis interface

• Trial does not follow Nokia document guideline due to space limitation in test bed room. Actual condition should apply cabinet for outdoor (FCOA) and indoor (FCIA)

• Configuration 12/12/12/8 requires minimal 5E1 and 12/12/12 needs 4E1 minimum

Soc Classification level 25 © Nokia Siemens Networks