TGM 5, TGM 5-Ex Transmitter for angular position

Operating instruction 42/1434 EN Rev. 02

42/14-34 EN

A112.5

∅15

8∅

110j

6∅

60

B

D

32

35

61.511.5200

AC

Z-14961/1

E

Z-14961/2

PG 13.5 od./orM 18 x 1.5

55°

9.5

130±

0.2

8

Fig. 3 Dimensional drawing of TGM 5 (-Ex) with flange mounting(dimensions in mm)

42/14-34 EN

Z-14961/3

E

E

9

Cable entry Plug connection

Pg13.5 M 18 x 1.5 angled straight

E 71.5 90.5 ≈ 143 ≈ 157

TGM 5

friction bearing ball bearing

A ∅ 19f8 ∅ 10f8

B 1 × 45° 0.5 × 45°

C 3 ± 0.1 –

D 3.5 ± 0.1 –

View AVersion with plugconnection

to Fig. 3

11

42/14-34 EN

Output and power supply

Catalog No.optional model4th position

Electricalisolation

Powersupply Us

Max. powersupply con-sumption

Max.load

1 without 12...20 V DC 24 mA

without 12...36 V DC 24 mA

2 without 13.2...36 V DC 24 mA

without 13.2...26.4 V AC 24 mA

3 with 13.2...36 V DC 100 mA 600 Ω

with 13.2...26.4 V AC 100 mA 600 Ω

US 12V–( )IA

----------------------------

US 12V–( )IA

----------------------------

US 13 2V,( )–IA

----------------------------------

US 13 2V,( )–IA

---------------------------------- 1 4,×

36

42/14-34 EN

2) only with output 4...20 mA, 4-wire circuit (Catalog No. 14436-xx7xxx0)

Catalog No.optional model4th position

2-wirecircuit

3-wirecircuit

4-wirecircuit

JumperBr3

1 4...20 mA open

–––4...20 mA

0... 5 mA0...10 mA0...20 mA–

0... 5 mA0...10 mA0...20 mA4...20 mA2)

closedclosedclosedopen

2 –––4...20 mA

0... 5 mA0...10 mA0...20 mA–

0... 5 mA0...10 mA0...20 mA4...20 mA2)

closedclosedclosedopen

0... 5 mA0...10 mA0...20 mA4...20 mA2)

closedclosedclosedopen

3 0... 5 mA0...10 mA0...20 mA4...20 mA2)

closedclosedclosedopen

0... 5 mA0...10 mA0...20 mA4...20 mA2)

closedclosedclosedopen

37

42/14-34 EN

Explosion protection

Certificate of conformityPTB 03 ATEX 2118

DesignationII 2 G EEx ib IIC T6 orII 2 G EEx ib IIC T4

Temperature classT6 for max. 40 °C ambient temperatureT4 for max. 70 °C ambient temperature

Mounting of the unitWithin hazardous areas of Zone 1 or Zone 2

Supply and signal current circuitFor connection to a certified intrinsically safe current circuitwith the following maximum valuesU = 20 V, I = 35 mA, P = 700 mW

Effective internal inductance LiNegligibly low

Effective internal capacitance Ci between the connectionsNegligibly low

Effective internal capacitance Ci between the connections and case (ground)

≤ 6 nF

42

ABB Automation Products GmbHBorsigstr. 2, 63755 Alzenau, GermanyPhone +49 551 905534Fax. +49 551 905555CCCsupport.deapr@de.abb.com

© Copyright 2003 by ABB Automation Products GmbHWe reserve the right to technical amendments

This document is protected by copyright. Information in this doc-ument is intended only to assist the user in safe and efficient op-eration of the equipment. Its contents are not to be reproducedin full or part without prior approval of legal owner.

Subject to technical changesPrinted in the Fed. Rep. of Germany

42/1434 EN Rev. 02Edition 10.03