Racer RX RENAL STENT SYSTEM

Racer RX RENAL STENT SYSTEM

Medtronic BVEarl Bakkenstraat 106422 PJ HeerlenThe NetherlandsTel: +31.45.566.8000Fax: +31.45.566.8668

Via Martiri della Libertà 725030 Roncadelle (BS) – ItalyPhone: + 39 030 2589311

Hungerbüelstrasse 128500 Frauenfeld – Switzerland

www.medtronic.comwww.invatec.com

Order Information

Stent Diameter

(mm)

Stent Length (mm)

Minimum Sheath I.D.

(F/mm/in.)

Minimum Guide I.D.(F/mm/in.)

12(80 cm shaft)

12(80 cm shaft)

12(80 cm shaft)

12(130 cm shaft)

4 RCR412XS RCR412XL RCR418XS RCR418XL 5/1.67/0.065 6/1.68/0.066

5 RCR512XS RCR512XL RCR518XS RCR518XL 5/1.67/0.065 6/1.68/0.066

6 RCR612XS RCR612XL RCR618XS RCR618XL 5/1.67/0.065 6/1.68/0.066

7 RCR712XS RCR712XL RCR718XS RCR718XL 6/2.00/0.079 7/1.90/0.076

0.014-in./0.36-mm Rapid-Exchange Platform

Pressure Deployed Stent I.D. (mm)

(kPa) (atm) 4 5 6 7

507 5 3.5 4.6 5.6 6.4

608 6 3.6 4.7 5.8 6.6

709 7 3.7 4.8 5.9 6.8

811 8 3.8 5.0 6.1 7.0

912 9 3.9 5.1 6.2 7.1

1013 10 4.0 5.2 6.3 7.2

1115 11 4.0 5.2 6.4 7.3

1216 12 4.1 5.3 6.5 7.4

1317 13 4.1 5.4 6.6 7.5

1419 14 4.2 5.5 6.7 7.7

1520 15 4.2 5.5 6.8 7.8

0.014-in./0.36-mm Compliance

Nominal pressure Rated burst pressure

Product Code Discription

Shaft Length (cm), S–(Short) 80, L–(Long) 130

Platform, RX–0.014 in./0.36 mm

Length

Diameter

Product Code

RCR 4 12 X S

A4-RacerRX_05.indd 1 12/21/11 2:27 PM

Racer RX RENAL STENT SYSTEM

The Story Is in the DesignFlexibility to get you there. Strength to keep you there.

The Racer RX renal stent system features an exclusive modularstent design that balances strength with predeployment flexibilityand conformability to the vessel wall. The Racer RX stent followsthe legacy of the Racer stent, the first cobalt chromiumstent launched for renal applications.

Advanced cobalt chromium alloy:• High radial strength with thin struts and a lower profile.• Low recoil for enhanced lumen patency and precise deployment.• Immediate postprocedure MR imaging, under appropriate conditions.

Exclusive modular stent design:• Superb predeployment flexibility, requiring minimal force to track the stent into the lesion.• Small cell area and optimal fusion patterns for exceptional lesion coverage and to help minimize tissue prolapse.

Rapid-exchange delivery system:• Low crossing profile and true 0.014-in. guidewire compatibility for easy trackability.• Optimal balloon-stent interface for minimal balloon overhang and added security during delivery.

Why compromise strength for flexibility—or flexibility for strength—when you don’t need to?

The Proof Is in the Results

The Racer RX renal stent system’s exclusivedesign starts with an advanced

cobaltchromium alloy.

Individual rings created from the cobalt chromium alloy are formed into

sinusoidal elements.

The elements are laser-fused usingfusion patterns specifically designed toprovide an optimal balance of strength

and flexibility for each stent length.†

Stents are electropolished to create a smooth, edgeless finish.

Our patented Secure Technology stent retention system features

distal and proximal pillows that offer added security during delivery.

Superb predeployment flexibility for excellent deliverability

Flexibility (Predeployment Rigidity)*

Superior postdeployment stent conformability to help keep vessel’s native shape

Conformability (Postdeployment Rigidity)*

Racer RX

Competitor A

Competitor B

1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 0.20 0.60 1.00 1.40 1.80 2.20 2.60 3.00N/mm

Note: Data not available for Competitor C.

Advanced cobalt chromium alloy allows for exceptionally thin, strong struts without compromising radial strength

Strut Thickness*

0.0057 in. 0.0067 in. 0.0069 in. 0.0065 in.

Racer RX Competitor A Competitor B Competitor C

Smaller cell area is designed to better conform to the vessel wall and help minimize tissue prolapse

Cell Area*

Racer3.5 mm2

Competitor A2.8/5.6 mm2

Competitor B 6 mm2

Competitor C 7.9 mm2

Balloons are customized for each stent length to minimize overhang and to help protect healthy tissue

Balloon Overhang*

Racer RX0.56 mm

Competitor A0.65 mm

Competitor B 1.80 mm

Competitor C 1.12 mm

* Test data on file at Medtronic, Inc.† Fusion pattern for 4–6 mm diameter stents shown.

Cobalt chromium alloy allowsfor immediate postimplant MR imaging, under appropriate conditions

MR* (in Vivo) MR* (in Vitro)

Stainless Steel Stent

Cobalt Chromium Stent

Stainless Steel Stent

Cobalt Chromium Stent

A4-RacerRX_05.indd 2 12/21/11 2:27 PM