Post on 25-Mar-2021
RECEIVED: November 21, 2012
STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING
APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NUMBER
Flatirons Federal 1-4
2. TYPE OF WORK
DRILL NEW WELL REENTER P&A WELL DEEPEN WELL 3. FIELD OR WILDCAT
GREATER CISCO
4. TYPE OF WELLGas Well Coalbed Methane Well: NO
5. UNIT or COMMUNITIZATION AGREEMENT NAME
6. NAME OF OPERATORFLATIRONS RESOURCES, LLC
7. OPERATOR PHONE303 292-3902
8. ADDRESS OF OPERATOR303 E. 17th Ave, Denver, CO, 80203
9. OPERATOR E-MAILjeffj@flatironsllc.com
10. MINERAL LEASE NUMBER(FEDERAL, INDIAN, OR STATE)
UTU87659
11. MINERAL OWNERSHIP
FEDERAL INDIAN STATE FEE 12. SURFACE OWNERSHIP
FEDERAL INDIAN STATE FEE
13. NAME OF SURFACE OWNER (if box 12 = 'fee')
14. SURFACE OWNER PHONE (if box 12 = 'fee')
15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee')
16. SURFACE OWNER E-MAIL (if box 12 = 'fee')
17. INDIAN ALLOTTEE OR TRIBE NAME(if box 12 = 'INDIAN')
18. INTEND TO COMMINGLE PRODUCTION FROMMULTIPLE FORMATIONS
YES (Submit Commingling Application) NO
19. SLANT
VERTICAL DIRECTIONAL HORIZONTAL
20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN
LOCATION AT SURFACE 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
Top of Uppermost Producing Zone 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
At Total Depth 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
21. COUNTYGRAND
22. DISTANCE TO NEAREST LEASE LINE (Feet)757
23. NUMBER OF ACRES IN DRILLING UNIT320
25. DISTANCE TO NEAREST WELL IN SAME POOL(Applied For Drilling or Completed)
1825
26. PROPOSED DEPTHMD: 1100 TVD: 1100
27. ELEVATION - GROUND LEVEL
4945
28. BOND NUMBER
UTB000511
29. SOURCE OF DRILLING WATER /WATER RIGHTS APPROVAL NUMBER IF APPLICABLE
municipal
Hole, Casing, and Cement Information
String Hole Size Casing Size Length Weight Grade & Thread Max Mud Wt. Cement Sacks Yield Weight
Cond 17 14 0 - 40 55.0 H-40 ST&C 9.0 Class G 35 1.17 15.8
Surf 12.25 9.625 0 - 250 32.3 H-40 ST&C 9.0 Class G 70 1.84 12.8
I1 8.75 7 0 - 860 7.17 H-40 ST&C 9.0 Class G 100 2.02 12.8
ATTACHMENTS
VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES
WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN
AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER
DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP
NAME Sharon Wells TITLE Sr. Engr. Tech PHONE 303 292-3902
SIGNATURE DATE 11/12/2012 EMAIL Sharonw@flatironsllc.com
API NUMBER ASSIGNED
43019500290000
Permit Manager
APPROVAL
FORM 3
AMENDED REPORT
API Well Number: 43019500290000
CONFIDE
NTIAL
API Well Number: 43019500290000
FORM 3STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES AMENDEDREPORTDIVISION OF OIL, GAS AND MINING
APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NFUaMBEnRsFederal 1-4
2. TYPE OF WORK 3. FIELD OR WILDCATDRILLNEWWELL REENTER P&AWELL DEEPEN WELLI GREATER CISCO
4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO
6. NAME OF OPERATOR 7. OPERATOR PHONEFLATIRONSRESOURCES, LLC 303 292-3902
8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL303 E. 17th Ave, Denver, CO, 80203 jeffj@flatironsllc.com
10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORSTE)87659 FEDERAL INDIANISTATE FEE FEDERAL INDIAN STATE FEEI
13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')
15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')
17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT
(if box 12 = 'INDIAN')MULTIPLE FORMATIONS
YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL
20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN
LOCATION AT SURFACE 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
Top of Uppermost Producing Zone 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
AtTotalDepth 1402FNL 757FEL SENE 4 19.0S 25.0 E S
21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITGRAND 757 320
25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 1100 TVD: 1100
1825
27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATERIWATER RIGHTS APPROVAL NUMBER IF APPLICABLE
4945 UTBOOO511 municipal
Hole, Casing, and Cement Information
String Hole Size Casing Size Length Weight Grade & Thread Max Mud Wt. Cement Sacks Yield Weight
Cond 17 14 0 - 40 55.0 H-40 ST&C 9.0 Class G 35 1.17 15.8
Surf 12.25 9.625 0 - 250 32.3 H-40 ST&C 9.0 Class G 70 1.84 12.8
11 8.75 7 0 - 860 7.17 H-40 ST&C 9.0 Class G 100 2.02 12.8
ATTACHMENTS
VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES
WELL PLATOR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN
AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT(IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER
DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLYOR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP
NAME Sharon Wells TITLESr. Engr. Tech PHONE 303 292-3902
SIGNATURE DATE 11/12/2012 EMAIL Sharonw@flatironsllc.com
API NUMBER ASSIGNED APPROVAL43019500290000
Permit Manager
RECEIVED: November 21,
API Well Number: 43019500290000
FORM 3STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES AMENDEDREPORTDIVISION OF OIL, GAS AND MINING
APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NFUaMBEnRsFederal 1-4
2. TYPE OF WORK 3. FIELD OR WILDCATDRILLNEWWELL REENTER P&AWELL DEEPEN WELLI GREATER CISCO
4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO
6. NAME OF OPERATOR 7. OPERATOR PHONEFLATIRONSRESOURCES, LLC 303 292-3902
8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL303 E. 17th Ave, Denver, CO, 80203 jeffj@flatironsllc.com
10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORSTE)87659 FEDERAL INDIANISTATE FEE FEDERAL INDIAN STATE FEEI
13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')
15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')
17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT
(if box 12 = 'INDIAN')MULTIPLE FORMATIONS
YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL
20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN
LOCATION AT SURFACE 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
Top of Uppermost Producing Zone 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
AtTotalDepth 1402FNL 757FEL SENE 4 19.0S 25.0 E S
21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITGRAND 757 320
25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 1100 TVD: 1100
1825
27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATERIWATER RIGHTS APPROVAL NUMBER IF APPLICABLE
4945 UTBOOO511 municipal
Hole, Casing, and Cement Information
String Hole Size Casing Size Length Weight Grade & Thread Max Mud Wt. Cement Sacks Yield Weight
Cond 17 14 0 - 40 55.0 H-40 ST&C 9.0 Class G 35 1.17 15.8
Surf 12.25 9.625 0 - 250 32.3 H-40 ST&C 9.0 Class G 70 1.84 12.8
11 8.75 7 0 - 860 7.17 H-40 ST&C 9.0 Class G 100 2.02 12.8
ATTACHMENTS
VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES
WELL PLATOR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN
AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT(IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER
DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLYOR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP
NAME Sharon Wells TITLESr. Engr. Tech PHONE 303 292-3902
SIGNATURE DATE 11/12/2012 EMAIL Sharonw@flatironsllc.com
API NUMBER ASSIGNED APPROVAL43019500290000
Permit Manager
RECEIVED: November 21,
API Well Number: 43019500290000
FORM 3STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES AMENDEDREPORTDIVISION OF OIL, GAS AND MINING
APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NFUaMBEnRsFederal 1-4
2. TYPE OF WORK 3. FIELD OR WILDCATDRILLNEWWELL REENTER P&AWELL DEEPEN WELLI GREATER CISCO
4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO
6. NAME OF OPERATOR 7. OPERATOR PHONEFLATIRONSRESOURCES, LLC 303 292-3902
8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL303 E. 17th Ave, Denver, CO, 80203 jeffj@flatironsllc.com
10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORSTE)87659 FEDERAL INDIANISTATE FEE FEDERAL INDIAN STATE FEEI
13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')
15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')
17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT
(if box 12 = 'INDIAN')MULTIPLE FORMATIONS
YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL
20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN
LOCATION AT SURFACE 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
Top of Uppermost Producing Zone 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
AtTotalDepth 1402FNL 757FEL SENE 4 19.0S 25.0 E S
21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITGRAND 757 320
25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 1100 TVD: 1100
1825
27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATERIWATER RIGHTS APPROVAL NUMBER IF APPLICABLE
4945 UTBOOO511 municipal
Hole, Casing, and Cement Information
String Hole Size Casing Size Length Weight Grade & Thread Max Mud Wt. Cement Sacks Yield Weight
Cond 17 14 0 - 40 55.0 H-40 ST&C 9.0 Class G 35 1.17 15.8
Surf 12.25 9.625 0 - 250 32.3 H-40 ST&C 9.0 Class G 70 1.84 12.8
11 8.75 7 0 - 860 7.17 H-40 ST&C 9.0 Class G 100 2.02 12.8
ATTACHMENTS
VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES
WELL PLATOR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN
AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT(IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER
DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLYOR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP
NAME Sharon Wells TITLESr. Engr. Tech PHONE 303 292-3902
SIGNATURE DATE 11/12/2012 EMAIL Sharonw@flatironsllc.com
API NUMBER ASSIGNED APPROVAL43019500290000
Permit Manager
RECEIVED: November 21,
API Well Number: 43019500290000
FORM 3STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES AMENDEDREPORTDIVISION OF OIL, GAS AND MINING
APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NFUaMBEnRsFederal 1-4
2. TYPE OF WORK 3. FIELD OR WILDCATDRILLNEWWELL REENTER P&AWELL DEEPEN WELLI GREATER CISCO
4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO
6. NAME OF OPERATOR 7. OPERATOR PHONEFLATIRONSRESOURCES, LLC 303 292-3902
8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL303 E. 17th Ave, Denver, CO, 80203 jeffj@flatironsllc.com
10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORSTE)87659 FEDERAL INDIANISTATE FEE FEDERAL INDIAN STATE FEEI
13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')
15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')
17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT
(if box 12 = 'INDIAN')MULTIPLE FORMATIONS
YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL
20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN
LOCATION AT SURFACE 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
Top of Uppermost Producing Zone 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
AtTotalDepth 1402FNL 757FEL SENE 4 19.0S 25.0 E S
21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITGRAND 757 320
25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 1100 TVD: 1100
1825
27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATERIWATER RIGHTS APPROVAL NUMBER IF APPLICABLE
4945 UTBOOO511 municipal
Hole, Casing, and Cement Information
String Hole Size Casing Size Length Weight Grade & Thread Max Mud Wt. Cement Sacks Yield Weight
Cond 17 14 0 - 40 55.0 H-40 ST&C 9.0 Class G 35 1.17 15.8
Surf 12.25 9.625 0 - 250 32.3 H-40 ST&C 9.0 Class G 70 1.84 12.8
11 8.75 7 0 - 860 7.17 H-40 ST&C 9.0 Class G 100 2.02 12.8
ATTACHMENTS
VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES
WELL PLATOR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN
AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT(IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER
DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLYOR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP
NAME Sharon Wells TITLESr. Engr. Tech PHONE 303 292-3902
SIGNATURE DATE 11/12/2012 EMAIL Sharonw@flatironsllc.com
API NUMBER ASSIGNED APPROVAL43019500290000
Permit Manager
RECEIVED: November 21,
API Well Number: 43019500290000
FORM 3STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES AMENDEDREPORTDIVISION OF OIL, GAS AND MINING
APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NFUaMBEnRsFederal 1-4
2. TYPE OF WORK 3. FIELD OR WILDCATDRILLNEWWELL REENTER P&AWELL DEEPEN WELLI GREATER CISCO
4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO
6. NAME OF OPERATOR 7. OPERATOR PHONEFLATIRONSRESOURCES, LLC 303 292-3902
8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL303 E. 17th Ave, Denver, CO, 80203 jeffj@flatironsllc.com
10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORSTE)87659 FEDERAL INDIANISTATE FEE FEDERAL INDIAN STATE FEEI
13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')
15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')
17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT
(if box 12 = 'INDIAN')MULTIPLE FORMATIONS
YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL
20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN
LOCATION AT SURFACE 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
Top of Uppermost Producing Zone 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
AtTotalDepth 1402FNL 757FEL SENE 4 19.0S 25.0 E S
21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITGRAND 757 320
25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 1100 TVD: 1100
1825
27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATERIWATER RIGHTS APPROVAL NUMBER IF APPLICABLE
4945 UTBOOO511 municipal
Hole, Casing, and Cement Information
String Hole Size Casing Size Length Weight Grade & Thread Max Mud Wt. Cement Sacks Yield Weight
Cond 17 14 0 - 40 55.0 H-40 ST&C 9.0 Class G 35 1.17 15.8
Surf 12.25 9.625 0 - 250 32.3 H-40 ST&C 9.0 Class G 70 1.84 12.8
11 8.75 7 0 - 860 7.17 H-40 ST&C 9.0 Class G 100 2.02 12.8
ATTACHMENTS
VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES
WELL PLATOR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN
AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT(IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER
DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLYOR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP
NAME Sharon Wells TITLESr. Engr. Tech PHONE 303 292-3902
SIGNATURE DATE 11/12/2012 EMAIL Sharonw@flatironsllc.com
API NUMBER ASSIGNED APPROVAL43019500290000
Permit Manager
RECEIVED: November 21,
API Well Number: 43019500290000
FORM 3STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES AMENDEDREPORTDIVISION OF OIL, GAS AND MINING
APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NFUaMBEnRsFederal 1-4
2. TYPE OF WORK 3. FIELD OR WILDCATDRILLNEWWELL REENTER P&AWELL DEEPEN WELLI GREATER CISCO
4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO
6. NAME OF OPERATOR 7. OPERATOR PHONEFLATIRONSRESOURCES, LLC 303 292-3902
8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL303 E. 17th Ave, Denver, CO, 80203 jeffj@flatironsllc.com
10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORSTE)87659 FEDERAL INDIANISTATE FEE FEDERAL INDIAN STATE FEEI
13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')
15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')
17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT
(if box 12 = 'INDIAN')MULTIPLE FORMATIONS
YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL
20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN
LOCATION AT SURFACE 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
Top of Uppermost Producing Zone 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
AtTotalDepth 1402FNL 757FEL SENE 4 19.0S 25.0 E S
21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITGRAND 757 320
25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 1100 TVD: 1100
1825
27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATERIWATER RIGHTS APPROVAL NUMBER IF APPLICABLE
4945 UTBOOO511 municipal
Hole, Casing, and Cement Information
String Hole Size Casing Size Length Weight Grade & Thread Max Mud Wt. Cement Sacks Yield Weight
Cond 17 14 0 - 40 55.0 H-40 ST&C 9.0 Class G 35 1.17 15.8
Surf 12.25 9.625 0 - 250 32.3 H-40 ST&C 9.0 Class G 70 1.84 12.8
11 8.75 7 0 - 860 7.17 H-40 ST&C 9.0 Class G 100 2.02 12.8
ATTACHMENTS
VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES
WELL PLATOR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN
AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT(IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER
DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLYOR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP
NAME Sharon Wells TITLESr. Engr. Tech PHONE 303 292-3902
SIGNATURE DATE 11/12/2012 EMAIL Sharonw@flatironsllc.com
API NUMBER ASSIGNED APPROVAL43019500290000
Permit Manager
RECEIVED: November 21,
API Well Number: 43019500290000
FORM 3STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES AMENDEDREPORTDIVISION OF OIL, GAS AND MINING
APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NFUaMBEnRsFederal 1-4
2. TYPE OF WORK 3. FIELD OR WILDCATDRILLNEWWELL REENTER P&AWELL DEEPEN WELLI GREATER CISCO
4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO
6. NAME OF OPERATOR 7. OPERATOR PHONEFLATIRONSRESOURCES, LLC 303 292-3902
8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL303 E. 17th Ave, Denver, CO, 80203 jeffj@flatironsllc.com
10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORSTE)87659 FEDERAL INDIANISTATE FEE FEDERAL INDIAN STATE FEEI
13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')
15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')
17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT
(if box 12 = 'INDIAN')MULTIPLE FORMATIONS
YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL
20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN
LOCATION AT SURFACE 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
Top of Uppermost Producing Zone 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
AtTotalDepth 1402FNL 757FEL SENE 4 19.0S 25.0 E S
21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITGRAND 757 320
25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 1100 TVD: 1100
1825
27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATERIWATER RIGHTS APPROVAL NUMBER IF APPLICABLE
4945 UTBOOO511 municipal
Hole, Casing, and Cement Information
String Hole Size Casing Size Length Weight Grade & Thread Max Mud Wt. Cement Sacks Yield Weight
Cond 17 14 0 - 40 55.0 H-40 ST&C 9.0 Class G 35 1.17 15.8
Surf 12.25 9.625 0 - 250 32.3 H-40 ST&C 9.0 Class G 70 1.84 12.8
11 8.75 7 0 - 860 7.17 H-40 ST&C 9.0 Class G 100 2.02 12.8
ATTACHMENTS
VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES
WELL PLATOR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN
AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT(IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER
DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLYOR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP
NAME Sharon Wells TITLESr. Engr. Tech PHONE 303 292-3902
SIGNATURE DATE 11/12/2012 EMAIL Sharonw@flatironsllc.com
API NUMBER ASSIGNED APPROVAL43019500290000
Permit Manager
RECEIVED: November 21,
API Well Number: 43019500290000
FORM 3STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES AMENDEDREPORTDIVISION OF OIL, GAS AND MINING
APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NFUaMBEnRsFederal 1-4
2. TYPE OF WORK 3. FIELD OR WILDCATDRILLNEWWELL REENTER P&AWELL DEEPEN WELLI GREATER CISCO
4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO
6. NAME OF OPERATOR 7. OPERATOR PHONEFLATIRONSRESOURCES, LLC 303 292-3902
8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL303 E. 17th Ave, Denver, CO, 80203 jeffj@flatironsllc.com
10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORSTE)87659 FEDERAL INDIANISTATE FEE FEDERAL INDIAN STATE FEEI
13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')
15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')
17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT
(if box 12 = 'INDIAN')MULTIPLE FORMATIONS
YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL
20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN
LOCATION AT SURFACE 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
Top of Uppermost Producing Zone 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
AtTotalDepth 1402FNL 757FEL SENE 4 19.0S 25.0 E S
21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITGRAND 757 320
25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 1100 TVD: 1100
1825
27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATERIWATER RIGHTS APPROVAL NUMBER IF APPLICABLE
4945 UTBOOO511 municipal
Hole, Casing, and Cement Information
String Hole Size Casing Size Length Weight Grade & Thread Max Mud Wt. Cement Sacks Yield Weight
Cond 17 14 0 - 40 55.0 H-40 ST&C 9.0 Class G 35 1.17 15.8
Surf 12.25 9.625 0 - 250 32.3 H-40 ST&C 9.0 Class G 70 1.84 12.8
11 8.75 7 0 - 860 7.17 H-40 ST&C 9.0 Class G 100 2.02 12.8
ATTACHMENTS
VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES
WELL PLATOR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN
AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT(IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER
DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLYOR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP
NAME Sharon Wells TITLESr. Engr. Tech PHONE 303 292-3902
SIGNATURE DATE 11/12/2012 EMAIL Sharonw@flatironsllc.com
API NUMBER ASSIGNED APPROVAL43019500290000
Permit Manager
RECEIVED: November 21,
API Well Number: 43019500290000
FORM 3STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES AMENDEDREPORTDIVISION OF OIL, GAS AND MINING
APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NFUaMBEnRsFederal 1-4
2. TYPE OF WORK 3. FIELD OR WILDCATDRILLNEWWELL REENTER P&AWELL DEEPEN WELLI GREATER CISCO
4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO
6. NAME OF OPERATOR 7. OPERATOR PHONEFLATIRONSRESOURCES, LLC 303 292-3902
8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL303 E. 17th Ave, Denver, CO, 80203 jeffj@flatironsllc.com
10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORSTE)87659 FEDERAL INDIANISTATE FEE FEDERAL INDIAN STATE FEEI
13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')
15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')
17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT
(if box 12 = 'INDIAN')MULTIPLE FORMATIONS
YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL
20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN
LOCATION AT SURFACE 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
Top of Uppermost Producing Zone 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
AtTotalDepth 1402FNL 757FEL SENE 4 19.0S 25.0 E S
21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITGRAND 757 320
25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 1100 TVD: 1100
1825
27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATERIWATER RIGHTS APPROVAL NUMBER IF APPLICABLE
4945 UTBOOO511 municipal
Hole, Casing, and Cement Information
String Hole Size Casing Size Length Weight Grade & Thread Max Mud Wt. Cement Sacks Yield Weight
Cond 17 14 0 - 40 55.0 H-40 ST&C 9.0 Class G 35 1.17 15.8
Surf 12.25 9.625 0 - 250 32.3 H-40 ST&C 9.0 Class G 70 1.84 12.8
11 8.75 7 0 - 860 7.17 H-40 ST&C 9.0 Class G 100 2.02 12.8
ATTACHMENTS
VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES
WELL PLATOR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN
AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT(IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER
DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLYOR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP
NAME Sharon Wells TITLESr. Engr. Tech PHONE 303 292-3902
SIGNATURE DATE 11/12/2012 EMAIL Sharonw@flatironsllc.com
API NUMBER ASSIGNED APPROVAL43019500290000
Permit Manager
RECEIVED: November 21,
API Well Number: 43019500290000
FORM 3STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES AMENDEDREPORTDIVISION OF OIL, GAS AND MINING
APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NFUaMBEnRsFederal 1-4
2. TYPE OF WORK 3. FIELD OR WILDCATDRILLNEWWELL REENTER P&AWELL DEEPEN WELLI GREATER CISCO
4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO
6. NAME OF OPERATOR 7. OPERATOR PHONEFLATIRONSRESOURCES, LLC 303 292-3902
8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL303 E. 17th Ave, Denver, CO, 80203 jeffj@flatironsllc.com
10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORSTE)87659 FEDERAL INDIANISTATE FEE FEDERAL INDIAN STATE FEEI
13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')
15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')
17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT
(if box 12 = 'INDIAN')MULTIPLE FORMATIONS
YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL
20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN
LOCATION AT SURFACE 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
Top of Uppermost Producing Zone 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
AtTotalDepth 1402FNL 757FEL SENE 4 19.0S 25.0 E S
21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITGRAND 757 320
25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 1100 TVD: 1100
1825
27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATERIWATER RIGHTS APPROVAL NUMBER IF APPLICABLE
4945 UTBOOO511 municipal
Hole, Casing, and Cement Information
String Hole Size Casing Size Length Weight Grade & Thread Max Mud Wt. Cement Sacks Yield Weight
Cond 17 14 0 - 40 55.0 H-40 ST&C 9.0 Class G 35 1.17 15.8
Surf 12.25 9.625 0 - 250 32.3 H-40 ST&C 9.0 Class G 70 1.84 12.8
11 8.75 7 0 - 860 7.17 H-40 ST&C 9.0 Class G 100 2.02 12.8
ATTACHMENTS
VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES
WELL PLATOR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN
AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT(IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER
DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLYOR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP
NAME Sharon Wells TITLESr. Engr. Tech PHONE 303 292-3902
SIGNATURE DATE 11/12/2012 EMAIL Sharonw@flatironsllc.com
API NUMBER ASSIGNED APPROVAL43019500290000
Permit Manager
RECEIVED: November 21,
API Well Number: 43019500290000
FORM 3STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES AMENDEDREPORTDIVISION OF OIL, GAS AND MINING
APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NFUaMBEnRsFederal 1-4
2. TYPE OF WORK 3. FIELD OR WILDCATDRILLNEWWELL REENTER P&AWELL DEEPEN WELLI GREATER CISCO
4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO
6. NAME OF OPERATOR 7. OPERATOR PHONEFLATIRONSRESOURCES, LLC 303 292-3902
8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL303 E. 17th Ave, Denver, CO, 80203 jeffj@flatironsllc.com
10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORSTE)87659 FEDERAL INDIANISTATE FEE FEDERAL INDIAN STATE FEEI
13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')
15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')
17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT
(if box 12 = 'INDIAN')MULTIPLE FORMATIONS
YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL
20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN
LOCATION AT SURFACE 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
Top of Uppermost Producing Zone 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
AtTotalDepth 1402FNL 757FEL SENE 4 19.0S 25.0 E S
21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITGRAND 757 320
25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 1100 TVD: 1100
1825
27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATERIWATER RIGHTS APPROVAL NUMBER IF APPLICABLE
4945 UTBOOO511 municipal
Hole, Casing, and Cement Information
String Hole Size Casing Size Length Weight Grade & Thread Max Mud Wt. Cement Sacks Yield Weight
Cond 17 14 0 - 40 55.0 H-40 ST&C 9.0 Class G 35 1.17 15.8
Surf 12.25 9.625 0 - 250 32.3 H-40 ST&C 9.0 Class G 70 1.84 12.8
11 8.75 7 0 - 860 7.17 H-40 ST&C 9.0 Class G 100 2.02 12.8
ATTACHMENTS
VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES
WELL PLATOR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN
AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT(IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER
DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLYOR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP
NAME Sharon Wells TITLESr. Engr. Tech PHONE 303 292-3902
SIGNATURE DATE 11/12/2012 EMAIL Sharonw@flatironsllc.com
API NUMBER ASSIGNED APPROVAL43019500290000
Permit Manager
RECEIVED: November 21,
API Well Number: 43019500290000
FORM 3STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES AMENDEDREPORTDIVISION OF OIL, GAS AND MINING
APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NFUaMBEnRsFederal 1-4
2. TYPE OF WORK 3. FIELD OR WILDCATDRILLNEWWELL REENTER P&AWELL DEEPEN WELLI GREATER CISCO
4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO
6. NAME OF OPERATOR 7. OPERATOR PHONEFLATIRONSRESOURCES, LLC 303 292-3902
8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL303 E. 17th Ave, Denver, CO, 80203 jeffj@flatironsllc.com
10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORSTE)87659 FEDERAL INDIANISTATE FEE FEDERAL INDIAN STATE FEEI
13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')
15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')
17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT
(if box 12 = 'INDIAN')MULTIPLE FORMATIONS
YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL
20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN
LOCATION AT SURFACE 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
Top of Uppermost Producing Zone 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
AtTotalDepth 1402FNL 757FEL SENE 4 19.0S 25.0 E S
21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITGRAND 757 320
25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 1100 TVD: 1100
1825
27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATERIWATER RIGHTS APPROVAL NUMBER IF APPLICABLE
4945 UTBOOO511 municipal
Hole, Casing, and Cement Information
String Hole Size Casing Size Length Weight Grade & Thread Max Mud Wt. Cement Sacks Yield Weight
Cond 17 14 0 - 40 55.0 H-40 ST&C 9.0 Class G 35 1.17 15.8
Surf 12.25 9.625 0 - 250 32.3 H-40 ST&C 9.0 Class G 70 1.84 12.8
11 8.75 7 0 - 860 7.17 H-40 ST&C 9.0 Class G 100 2.02 12.8
ATTACHMENTS
VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES
WELL PLATOR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN
AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT(IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER
DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLYOR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP
NAME Sharon Wells TITLESr. Engr. Tech PHONE 303 292-3902
SIGNATURE DATE 11/12/2012 EMAIL Sharonw@flatironsllc.com
API NUMBER ASSIGNED APPROVAL43019500290000
Permit Manager
RECEIVED: November 21,
API Well Number: 43019500290000
FORM 3STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES AMENDEDREPORTDIVISION OF OIL, GAS AND MINING
APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NFUaMBEnRsFederal 1-4
2. TYPE OF WORK 3. FIELD OR WILDCATDRILLNEWWELL REENTER P&AWELL DEEPEN WELLI GREATER CISCO
4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO
6. NAME OF OPERATOR 7. OPERATOR PHONEFLATIRONSRESOURCES, LLC 303 292-3902
8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL303 E. 17th Ave, Denver, CO, 80203 jeffj@flatironsllc.com
10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORSTE)87659 FEDERAL INDIANISTATE FEE FEDERAL INDIAN STATE FEEI
13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')
15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')
17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT
(if box 12 = 'INDIAN')MULTIPLE FORMATIONS
YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL
20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN
LOCATION AT SURFACE 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
Top of Uppermost Producing Zone 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
AtTotalDepth 1402FNL 757FEL SENE 4 19.0S 25.0 E S
21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITGRAND 757 320
25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 1100 TVD: 1100
1825
27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATERIWATER RIGHTS APPROVAL NUMBER IF APPLICABLE
4945 UTBOOO511 municipal
Hole, Casing, and Cement Information
String Hole Size Casing Size Length Weight Grade & Thread Max Mud Wt. Cement Sacks Yield Weight
Cond 17 14 0 - 40 55.0 H-40 ST&C 9.0 Class G 35 1.17 15.8
Surf 12.25 9.625 0 - 250 32.3 H-40 ST&C 9.0 Class G 70 1.84 12.8
11 8.75 7 0 - 860 7.17 H-40 ST&C 9.0 Class G 100 2.02 12.8
ATTACHMENTS
VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES
WELL PLATOR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN
AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT(IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER
DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLYOR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP
NAME Sharon Wells TITLESr. Engr. Tech PHONE 303 292-3902
SIGNATURE DATE 11/12/2012 EMAIL Sharonw@flatironsllc.com
API NUMBER ASSIGNED APPROVAL43019500290000
Permit Manager
RECEIVED: November 21,
API Well Number: 43019500290000
FORM 3STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES AMENDEDREPORTDIVISION OF OIL, GAS AND MINING
APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NFUaMBEnRsFederal 1-4
2. TYPE OF WORK 3. FIELD OR WILDCATDRILLNEWWELL REENTER P&AWELL DEEPEN WELLI GREATER CISCO
4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO
6. NAME OF OPERATOR 7. OPERATOR PHONEFLATIRONSRESOURCES, LLC 303 292-3902
8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL303 E. 17th Ave, Denver, CO, 80203 jeffj@flatironsllc.com
10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORSTE)87659 FEDERAL INDIANISTATE FEE FEDERAL INDIAN STATE FEEI
13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')
15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')
17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT
(if box 12 = 'INDIAN')MULTIPLE FORMATIONS
YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL
20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN
LOCATION AT SURFACE 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
Top of Uppermost Producing Zone 1402 FNL 757 FEL SENE 4 19.0 S 25.0 E S
AtTotalDepth 1402FNL 757FEL SENE 4 19.0S 25.0 E S
21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITGRAND 757 320
25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 1100 TVD: 1100
1825
27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATERIWATER RIGHTS APPROVAL NUMBER IF APPLICABLE
4945 UTBOOO511 municipal
Hole, Casing, and Cement Information
String Hole Size Casing Size Length Weight Grade & Thread Max Mud Wt. Cement Sacks Yield Weight
Cond 17 14 0 - 40 55.0 H-40 ST&C 9.0 Class G 35 1.17 15.8
Surf 12.25 9.625 0 - 250 32.3 H-40 ST&C 9.0 Class G 70 1.84 12.8
11 8.75 7 0 - 860 7.17 H-40 ST&C 9.0 Class G 100 2.02 12.8
ATTACHMENTS
VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES
WELL PLATOR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN
AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT(IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER
DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLYOR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP
NAME Sharon Wells TITLESr. Engr. Tech PHONE 303 292-3902
SIGNATURE DATE 11/12/2012 EMAIL Sharonw@flatironsllc.com
API NUMBER ASSIGNED APPROVAL43019500290000
Permit Manager
RECEIVED: November 21,
RECEIVED: November 12, 2012
API Well Number: 43019500290000
CONFIDE
NTIAL
API Well Number: 43019500290000
Eight Point Drilling PlanFlatirons Federal #1-4
September 4, 2012
Project Summary: Flatirons Resources LLC,as operator, intends to drill 1100 ft helium wellon the crestof Harley Dome. The well location is in the middleof three historicaltests on the anticline whichprovide the gas composition and pressure of the Entrada formation. The location will be accessed by anexisting two track road. A trailer mounted rig willbe used to drillthe well. Forty feet of 14 inchconductor pipe will be set, followedby 250 feet of 9-5/8 inch surface casing, and 860 feet of 7 inchcasing to be set above the objective Entrada zone, top setting the zone. Once the cement has beenallowed to set for eight hours the well will be drilledinto the Entrada. After reaching TD the well will beblown dry and the drill pipe will be tripped out of the well. Once the rig is moved off the well will beflow tested for fivedays to confirm gas composition and rate, Ifsufficient quality and quantity of gas isconfirmed through flow testing, a flow line will be run to a small pressure swing adsorption helium plantto remove the helium from the other inert gases.
1. Estimated Formation TopsTops Dakota At surface
Morrison 149'Top of Salt Wash Sand 566' DepletedBase of Salt Wash Sand 595'Entrada 860' Helium PotentialTD (100 feet into Entrada) 960Permitted depth 1,100
2. Estimated Depth and thickness of formations:Name Depth ThicknessSalt Wash (1) 566-595 30Entrada (2) 860-1110 250
Notes: (1) When drilledin the Lansdale Gov #13 well the Salt Wash had 5 psipressure see DP- 2(2) Had 155 psi and attached gas analysis when drilledthrough with the Lansdale Gov, #13 well
3. Pressure Control Equipment:A. Himes Drilling is providing rotating head/diverter and blooey line for the drilling the surface
and down tothe top of the Entrada (intermediate hole). lt is not expected that this intervalwillencounter significant gas. When the Lansdale Gov. #13 was drilledthe Salt Wash zonewas depleted to five psig. In the unlikely event the Salt Wash is not depleted and significantgas is encountered we will be prepared to pump fresh water to killthe zone.
Flatirons Federal #4-1: Drilling Plan Page 1 October 3,
API Well Number: 43019500290000
Eight Point Drilling PlanFlatirons Federal #1-4
September 4, 2012
Project Summary: Flatirons Resources LLC,as operator, intends to drill 1100 ft helium wellon the crestof Harley Dome. The well location is in the middleof three historicaltests on the anticline whichprovide the gas composition and pressure of the Entrada formation. The location will be accessed by anexisting two track road. A trailer mounted rig willbe used to drillthe well. Forty feet of 14 inchconductor pipe will be set, followedby 250 feet of 9-5/8 inch surface casing, and 860 feet of 7 inchcasing to be set above the objective Entrada zone, top setting the zone. Once the cement has beenallowed to set for eight hours the well will be drilledinto the Entrada. After reaching TD the well will beblown dry and the drill pipe will be tripped out of the well. Once the rig is moved off the well will beflow tested for fivedays to confirm gas composition and rate, Ifsufficient quality and quantity of gas isconfirmed through flow testing, a flow line will be run to a small pressure swing adsorption helium plantto remove the helium from the other inert gases.
1. Estimated Formation TopsTops Dakota At surface
Morrison 149'Top of Salt Wash Sand 566' DepletedBase of Salt Wash Sand 595'Entrada 860' Helium PotentialTD (100 feet into Entrada) 960Permitted depth 1,100
2. Estimated Depth and thickness of formations:Name Depth ThicknessSalt Wash (1) 566-595 30Entrada (2) 860-1110 250
Notes: (1) When drilledin the Lansdale Gov #13 well the Salt Wash had 5 psipressure see DP- 2(2) Had 155 psi and attached gas analysis when drilledthrough with the Lansdale Gov, #13 well
3. Pressure Control Equipment:A. Himes Drilling is providing rotating head/diverter and blooey line for the drilling the surface
and down tothe top of the Entrada (intermediate hole). lt is not expected that this intervalwillencounter significant gas. When the Lansdale Gov. #13 was drilledthe Salt Wash zonewas depleted to five psig. In the unlikely event the Salt Wash is not depleted and significantgas is encountered we will be prepared to pump fresh water to killthe zone.
Flatirons Federal #4-1: Drilling Plan Page 1 October 3,
API Well Number: 43019500290000
Eight Point Drilling PlanFlatirons Federal #1-4
September 4, 2012
Project Summary: Flatirons Resources LLC,as operator, intends to drill 1100 ft helium wellon the crestof Harley Dome. The well location is in the middleof three historicaltests on the anticline whichprovide the gas composition and pressure of the Entrada formation. The location will be accessed by anexisting two track road. A trailer mounted rig willbe used to drillthe well. Forty feet of 14 inchconductor pipe will be set, followedby 250 feet of 9-5/8 inch surface casing, and 860 feet of 7 inchcasing to be set above the objective Entrada zone, top setting the zone. Once the cement has beenallowed to set for eight hours the well will be drilledinto the Entrada. After reaching TD the well will beblown dry and the drill pipe will be tripped out of the well. Once the rig is moved off the well will beflow tested for fivedays to confirm gas composition and rate, Ifsufficient quality and quantity of gas isconfirmed through flow testing, a flow line will be run to a small pressure swing adsorption helium plantto remove the helium from the other inert gases.
1. Estimated Formation TopsTops Dakota At surface
Morrison 149'Top of Salt Wash Sand 566' DepletedBase of Salt Wash Sand 595'Entrada 860' Helium PotentialTD (100 feet into Entrada) 960Permitted depth 1,100
2. Estimated Depth and thickness of formations:Name Depth ThicknessSalt Wash (1) 566-595 30Entrada (2) 860-1110 250
Notes: (1) When drilledin the Lansdale Gov #13 well the Salt Wash had 5 psipressure see DP- 2(2) Had 155 psi and attached gas analysis when drilledthrough with the Lansdale Gov, #13 well
3. Pressure Control Equipment:A. Himes Drilling is providing rotating head/diverter and blooey line for the drilling the surface
and down tothe top of the Entrada (intermediate hole). lt is not expected that this intervalwillencounter significant gas. When the Lansdale Gov. #13 was drilledthe Salt Wash zonewas depleted to five psig. In the unlikely event the Salt Wash is not depleted and significantgas is encountered we will be prepared to pump fresh water to killthe zone.
Flatirons Federal #4-1: Drilling Plan Page 1 October 3,
API Well Number: 43019500290000
Eight Point Drilling PlanFlatirons Federal #1-4
September 4, 2012
Project Summary: Flatirons Resources LLC,as operator, intends to drill 1100 ft helium wellon the crestof Harley Dome. The well location is in the middleof three historicaltests on the anticline whichprovide the gas composition and pressure of the Entrada formation. The location will be accessed by anexisting two track road. A trailer mounted rig willbe used to drillthe well. Forty feet of 14 inchconductor pipe will be set, followedby 250 feet of 9-5/8 inch surface casing, and 860 feet of 7 inchcasing to be set above the objective Entrada zone, top setting the zone. Once the cement has beenallowed to set for eight hours the well will be drilledinto the Entrada. After reaching TD the well will beblown dry and the drill pipe will be tripped out of the well. Once the rig is moved off the well will beflow tested for fivedays to confirm gas composition and rate, Ifsufficient quality and quantity of gas isconfirmed through flow testing, a flow line will be run to a small pressure swing adsorption helium plantto remove the helium from the other inert gases.
1. Estimated Formation TopsTops Dakota At surface
Morrison 149'Top of Salt Wash Sand 566' DepletedBase of Salt Wash Sand 595'Entrada 860' Helium PotentialTD (100 feet into Entrada) 960Permitted depth 1,100
2. Estimated Depth and thickness of formations:Name Depth ThicknessSalt Wash (1) 566-595 30Entrada (2) 860-1110 250
Notes: (1) When drilledin the Lansdale Gov #13 well the Salt Wash had 5 psipressure see DP- 2(2) Had 155 psi and attached gas analysis when drilledthrough with the Lansdale Gov, #13 well
3. Pressure Control Equipment:A. Himes Drilling is providing rotating head/diverter and blooey line for the drilling the surface
and down tothe top of the Entrada (intermediate hole). lt is not expected that this intervalwillencounter significant gas. When the Lansdale Gov. #13 was drilledthe Salt Wash zonewas depleted to five psig. In the unlikely event the Salt Wash is not depleted and significantgas is encountered we will be prepared to pump fresh water to killthe zone.
Flatirons Federal #4-1: Drilling Plan Page 1 October 3,
API Well Number: 43019500290000
Eight Point Drilling PlanFlatirons Federal #1-4
September 4, 2012
Project Summary: Flatirons Resources LLC,as operator, intends to drill 1100 ft helium wellon the crestof Harley Dome. The well location is in the middleof three historicaltests on the anticline whichprovide the gas composition and pressure of the Entrada formation. The location will be accessed by anexisting two track road. A trailer mounted rig willbe used to drillthe well. Forty feet of 14 inchconductor pipe will be set, followedby 250 feet of 9-5/8 inch surface casing, and 860 feet of 7 inchcasing to be set above the objective Entrada zone, top setting the zone. Once the cement has beenallowed to set for eight hours the well will be drilledinto the Entrada. After reaching TD the well will beblown dry and the drill pipe will be tripped out of the well. Once the rig is moved off the well will beflow tested for fivedays to confirm gas composition and rate, Ifsufficient quality and quantity of gas isconfirmed through flow testing, a flow line will be run to a small pressure swing adsorption helium plantto remove the helium from the other inert gases.
1. Estimated Formation TopsTops Dakota At surface
Morrison 149'Top of Salt Wash Sand 566' DepletedBase of Salt Wash Sand 595'Entrada 860' Helium PotentialTD (100 feet into Entrada) 960Permitted depth 1,100
2. Estimated Depth and thickness of formations:Name Depth ThicknessSalt Wash (1) 566-595 30Entrada (2) 860-1110 250
Notes: (1) When drilledin the Lansdale Gov #13 well the Salt Wash had 5 psipressure see DP- 2(2) Had 155 psi and attached gas analysis when drilledthrough with the Lansdale Gov, #13 well
3. Pressure Control Equipment:A. Himes Drilling is providing rotating head/diverter and blooey line for the drilling the surface
and down tothe top of the Entrada (intermediate hole). lt is not expected that this intervalwillencounter significant gas. When the Lansdale Gov. #13 was drilledthe Salt Wash zonewas depleted to five psig. In the unlikely event the Salt Wash is not depleted and significantgas is encountered we will be prepared to pump fresh water to killthe zone.
Flatirons Federal #4-1: Drilling Plan Page 1 October 3,
API Well Number: 43019500290000
Eight Point Drilling PlanFlatirons Federal #1-4
September 4, 2012
Project Summary: Flatirons Resources LLC,as operator, intends to drill 1100 ft helium wellon the crestof Harley Dome. The well location is in the middleof three historicaltests on the anticline whichprovide the gas composition and pressure of the Entrada formation. The location will be accessed by anexisting two track road. A trailer mounted rig willbe used to drillthe well. Forty feet of 14 inchconductor pipe will be set, followedby 250 feet of 9-5/8 inch surface casing, and 860 feet of 7 inchcasing to be set above the objective Entrada zone, top setting the zone. Once the cement has beenallowed to set for eight hours the well will be drilledinto the Entrada. After reaching TD the well will beblown dry and the drill pipe will be tripped out of the well. Once the rig is moved off the well will beflow tested for fivedays to confirm gas composition and rate, Ifsufficient quality and quantity of gas isconfirmed through flow testing, a flow line will be run to a small pressure swing adsorption helium plantto remove the helium from the other inert gases.
1. Estimated Formation TopsTops Dakota At surface
Morrison 149'Top of Salt Wash Sand 566' DepletedBase of Salt Wash Sand 595'Entrada 860' Helium PotentialTD (100 feet into Entrada) 960Permitted depth 1,100
2. Estimated Depth and thickness of formations:Name Depth ThicknessSalt Wash (1) 566-595 30Entrada (2) 860-1110 250
Notes: (1) When drilledin the Lansdale Gov #13 well the Salt Wash had 5 psipressure see DP- 2(2) Had 155 psi and attached gas analysis when drilledthrough with the Lansdale Gov, #13 well
3. Pressure Control Equipment:A. Himes Drilling is providing rotating head/diverter and blooey line for the drilling the surface
and down tothe top of the Entrada (intermediate hole). lt is not expected that this intervalwillencounter significant gas. When the Lansdale Gov. #13 was drilledthe Salt Wash zonewas depleted to five psig. In the unlikely event the Salt Wash is not depleted and significantgas is encountered we will be prepared to pump fresh water to killthe zone.
Flatirons Federal #4-1: Drilling Plan Page 1 October 3,
API Well Number: 43019500290000
Eight Point Drilling PlanFlatirons Federal #1-4
September 4, 2012
Project Summary: Flatirons Resources LLC,as operator, intends to drill 1100 ft helium wellon the crestof Harley Dome. The well location is in the middleof three historicaltests on the anticline whichprovide the gas composition and pressure of the Entrada formation. The location will be accessed by anexisting two track road. A trailer mounted rig willbe used to drillthe well. Forty feet of 14 inchconductor pipe will be set, followedby 250 feet of 9-5/8 inch surface casing, and 860 feet of 7 inchcasing to be set above the objective Entrada zone, top setting the zone. Once the cement has beenallowed to set for eight hours the well will be drilledinto the Entrada. After reaching TD the well will beblown dry and the drill pipe will be tripped out of the well. Once the rig is moved off the well will beflow tested for fivedays to confirm gas composition and rate, Ifsufficient quality and quantity of gas isconfirmed through flow testing, a flow line will be run to a small pressure swing adsorption helium plantto remove the helium from the other inert gases.
1. Estimated Formation TopsTops Dakota At surface
Morrison 149'Top of Salt Wash Sand 566' DepletedBase of Salt Wash Sand 595'Entrada 860' Helium PotentialTD (100 feet into Entrada) 960Permitted depth 1,100
2. Estimated Depth and thickness of formations:Name Depth ThicknessSalt Wash (1) 566-595 30Entrada (2) 860-1110 250
Notes: (1) When drilledin the Lansdale Gov #13 well the Salt Wash had 5 psipressure see DP- 2(2) Had 155 psi and attached gas analysis when drilledthrough with the Lansdale Gov, #13 well
3. Pressure Control Equipment:A. Himes Drilling is providing rotating head/diverter and blooey line for the drilling the surface
and down tothe top of the Entrada (intermediate hole). lt is not expected that this intervalwillencounter significant gas. When the Lansdale Gov. #13 was drilledthe Salt Wash zonewas depleted to five psig. In the unlikely event the Salt Wash is not depleted and significantgas is encountered we will be prepared to pump fresh water to killthe zone.
Flatirons Federal #4-1: Drilling Plan Page 1 October 3,
API Well Number: 43019500290000
Eight Point Drilling PlanFlatirons Federal #1-4
September 4, 2012
Project Summary: Flatirons Resources LLC,as operator, intends to drill 1100 ft helium wellon the crestof Harley Dome. The well location is in the middleof three historicaltests on the anticline whichprovide the gas composition and pressure of the Entrada formation. The location will be accessed by anexisting two track road. A trailer mounted rig willbe used to drillthe well. Forty feet of 14 inchconductor pipe will be set, followedby 250 feet of 9-5/8 inch surface casing, and 860 feet of 7 inchcasing to be set above the objective Entrada zone, top setting the zone. Once the cement has beenallowed to set for eight hours the well will be drilledinto the Entrada. After reaching TD the well will beblown dry and the drill pipe will be tripped out of the well. Once the rig is moved off the well will beflow tested for fivedays to confirm gas composition and rate, Ifsufficient quality and quantity of gas isconfirmed through flow testing, a flow line will be run to a small pressure swing adsorption helium plantto remove the helium from the other inert gases.
1. Estimated Formation TopsTops Dakota At surface
Morrison 149'Top of Salt Wash Sand 566' DepletedBase of Salt Wash Sand 595'Entrada 860' Helium PotentialTD (100 feet into Entrada) 960Permitted depth 1,100
2. Estimated Depth and thickness of formations:Name Depth ThicknessSalt Wash (1) 566-595 30Entrada (2) 860-1110 250
Notes: (1) When drilledin the Lansdale Gov #13 well the Salt Wash had 5 psipressure see DP- 2(2) Had 155 psi and attached gas analysis when drilledthrough with the Lansdale Gov, #13 well
3. Pressure Control Equipment:A. Himes Drilling is providing rotating head/diverter and blooey line for the drilling the surface
and down tothe top of the Entrada (intermediate hole). lt is not expected that this intervalwillencounter significant gas. When the Lansdale Gov. #13 was drilledthe Salt Wash zonewas depleted to five psig. In the unlikely event the Salt Wash is not depleted and significantgas is encountered we will be prepared to pump fresh water to killthe zone.
Flatirons Federal #4-1: Drilling Plan Page 1 October 3,
API Well Number: 43019500290000
Eight Point Drilling PlanFlatirons Federal #1-4
September 4, 2012
Project Summary: Flatirons Resources LLC,as operator, intends to drill 1100 ft helium wellon the crestof Harley Dome. The well location is in the middleof three historicaltests on the anticline whichprovide the gas composition and pressure of the Entrada formation. The location will be accessed by anexisting two track road. A trailer mounted rig willbe used to drillthe well. Forty feet of 14 inchconductor pipe will be set, followedby 250 feet of 9-5/8 inch surface casing, and 860 feet of 7 inchcasing to be set above the objective Entrada zone, top setting the zone. Once the cement has beenallowed to set for eight hours the well will be drilledinto the Entrada. After reaching TD the well will beblown dry and the drill pipe will be tripped out of the well. Once the rig is moved off the well will beflow tested for fivedays to confirm gas composition and rate, Ifsufficient quality and quantity of gas isconfirmed through flow testing, a flow line will be run to a small pressure swing adsorption helium plantto remove the helium from the other inert gases.
1. Estimated Formation TopsTops Dakota At surface
Morrison 149'Top of Salt Wash Sand 566' DepletedBase of Salt Wash Sand 595'Entrada 860' Helium PotentialTD (100 feet into Entrada) 960Permitted depth 1,100
2. Estimated Depth and thickness of formations:Name Depth ThicknessSalt Wash (1) 566-595 30Entrada (2) 860-1110 250
Notes: (1) When drilledin the Lansdale Gov #13 well the Salt Wash had 5 psipressure see DP- 2(2) Had 155 psi and attached gas analysis when drilledthrough with the Lansdale Gov, #13 well
3. Pressure Control Equipment:A. Himes Drilling is providing rotating head/diverter and blooey line for the drilling the surface
and down tothe top of the Entrada (intermediate hole). lt is not expected that this intervalwillencounter significant gas. When the Lansdale Gov. #13 was drilledthe Salt Wash zonewas depleted to five psig. In the unlikely event the Salt Wash is not depleted and significantgas is encountered we will be prepared to pump fresh water to killthe zone.
Flatirons Federal #4-1: Drilling Plan Page 1 October 3,
API Well Number: 43019500290000
Eight Point Drilling PlanFlatirons Federal #1-4
September 4, 2012
Project Summary: Flatirons Resources LLC,as operator, intends to drill 1100 ft helium wellon the crestof Harley Dome. The well location is in the middleof three historicaltests on the anticline whichprovide the gas composition and pressure of the Entrada formation. The location will be accessed by anexisting two track road. A trailer mounted rig willbe used to drillthe well. Forty feet of 14 inchconductor pipe will be set, followedby 250 feet of 9-5/8 inch surface casing, and 860 feet of 7 inchcasing to be set above the objective Entrada zone, top setting the zone. Once the cement has beenallowed to set for eight hours the well will be drilledinto the Entrada. After reaching TD the well will beblown dry and the drill pipe will be tripped out of the well. Once the rig is moved off the well will beflow tested for fivedays to confirm gas composition and rate, Ifsufficient quality and quantity of gas isconfirmed through flow testing, a flow line will be run to a small pressure swing adsorption helium plantto remove the helium from the other inert gases.
1. Estimated Formation TopsTops Dakota At surface
Morrison 149'Top of Salt Wash Sand 566' DepletedBase of Salt Wash Sand 595'Entrada 860' Helium PotentialTD (100 feet into Entrada) 960Permitted depth 1,100
2. Estimated Depth and thickness of formations:Name Depth ThicknessSalt Wash (1) 566-595 30Entrada (2) 860-1110 250
Notes: (1) When drilledin the Lansdale Gov #13 well the Salt Wash had 5 psipressure see DP- 2(2) Had 155 psi and attached gas analysis when drilledthrough with the Lansdale Gov, #13 well
3. Pressure Control Equipment:A. Himes Drilling is providing rotating head/diverter and blooey line for the drilling the surface
and down tothe top of the Entrada (intermediate hole). lt is not expected that this intervalwillencounter significant gas. When the Lansdale Gov. #13 was drilledthe Salt Wash zonewas depleted to five psig. In the unlikely event the Salt Wash is not depleted and significantgas is encountered we will be prepared to pump fresh water to killthe zone.
Flatirons Federal #4-1: Drilling Plan Page 1 October 3,
API Well Number: 43019500290000
Eight Point Drilling PlanFlatirons Federal #1-4
September 4, 2012
Project Summary: Flatirons Resources LLC,as operator, intends to drill 1100 ft helium wellon the crestof Harley Dome. The well location is in the middleof three historicaltests on the anticline whichprovide the gas composition and pressure of the Entrada formation. The location will be accessed by anexisting two track road. A trailer mounted rig willbe used to drillthe well. Forty feet of 14 inchconductor pipe will be set, followedby 250 feet of 9-5/8 inch surface casing, and 860 feet of 7 inchcasing to be set above the objective Entrada zone, top setting the zone. Once the cement has beenallowed to set for eight hours the well will be drilledinto the Entrada. After reaching TD the well will beblown dry and the drill pipe will be tripped out of the well. Once the rig is moved off the well will beflow tested for fivedays to confirm gas composition and rate, Ifsufficient quality and quantity of gas isconfirmed through flow testing, a flow line will be run to a small pressure swing adsorption helium plantto remove the helium from the other inert gases.
1. Estimated Formation TopsTops Dakota At surface
Morrison 149'Top of Salt Wash Sand 566' DepletedBase of Salt Wash Sand 595'Entrada 860' Helium PotentialTD (100 feet into Entrada) 960Permitted depth 1,100
2. Estimated Depth and thickness of formations:Name Depth ThicknessSalt Wash (1) 566-595 30Entrada (2) 860-1110 250
Notes: (1) When drilledin the Lansdale Gov #13 well the Salt Wash had 5 psipressure see DP- 2(2) Had 155 psi and attached gas analysis when drilledthrough with the Lansdale Gov, #13 well
3. Pressure Control Equipment:A. Himes Drilling is providing rotating head/diverter and blooey line for the drilling the surface
and down tothe top of the Entrada (intermediate hole). lt is not expected that this intervalwillencounter significant gas. When the Lansdale Gov. #13 was drilledthe Salt Wash zonewas depleted to five psig. In the unlikely event the Salt Wash is not depleted and significantgas is encountered we will be prepared to pump fresh water to killthe zone.
Flatirons Federal #4-1: Drilling Plan Page 1 October 3,
API Well Number: 43019500290000
Eight Point Drilling PlanFlatirons Federal #1-4
September 4, 2012
Project Summary: Flatirons Resources LLC,as operator, intends to drill 1100 ft helium wellon the crestof Harley Dome. The well location is in the middleof three historicaltests on the anticline whichprovide the gas composition and pressure of the Entrada formation. The location will be accessed by anexisting two track road. A trailer mounted rig willbe used to drillthe well. Forty feet of 14 inchconductor pipe will be set, followedby 250 feet of 9-5/8 inch surface casing, and 860 feet of 7 inchcasing to be set above the objective Entrada zone, top setting the zone. Once the cement has beenallowed to set for eight hours the well will be drilledinto the Entrada. After reaching TD the well will beblown dry and the drill pipe will be tripped out of the well. Once the rig is moved off the well will beflow tested for fivedays to confirm gas composition and rate, Ifsufficient quality and quantity of gas isconfirmed through flow testing, a flow line will be run to a small pressure swing adsorption helium plantto remove the helium from the other inert gases.
1. Estimated Formation TopsTops Dakota At surface
Morrison 149'Top of Salt Wash Sand 566' DepletedBase of Salt Wash Sand 595'Entrada 860' Helium PotentialTD (100 feet into Entrada) 960Permitted depth 1,100
2. Estimated Depth and thickness of formations:Name Depth ThicknessSalt Wash (1) 566-595 30Entrada (2) 860-1110 250
Notes: (1) When drilledin the Lansdale Gov #13 well the Salt Wash had 5 psipressure see DP- 2(2) Had 155 psi and attached gas analysis when drilledthrough with the Lansdale Gov, #13 well
3. Pressure Control Equipment:A. Himes Drilling is providing rotating head/diverter and blooey line for the drilling the surface
and down tothe top of the Entrada (intermediate hole). lt is not expected that this intervalwillencounter significant gas. When the Lansdale Gov. #13 was drilledthe Salt Wash zonewas depleted to five psig. In the unlikely event the Salt Wash is not depleted and significantgas is encountered we will be prepared to pump fresh water to killthe zone.
Flatirons Federal #4-1: Drilling Plan Page 1 October 3,
API Well Number: 43019500290000
Eight Point Drilling PlanFlatirons Federal #1-4
September 4, 2012
Project Summary: Flatirons Resources LLC,as operator, intends to drill 1100 ft helium wellon the crestof Harley Dome. The well location is in the middleof three historicaltests on the anticline whichprovide the gas composition and pressure of the Entrada formation. The location will be accessed by anexisting two track road. A trailer mounted rig willbe used to drillthe well. Forty feet of 14 inchconductor pipe will be set, followedby 250 feet of 9-5/8 inch surface casing, and 860 feet of 7 inchcasing to be set above the objective Entrada zone, top setting the zone. Once the cement has beenallowed to set for eight hours the well will be drilledinto the Entrada. After reaching TD the well will beblown dry and the drill pipe will be tripped out of the well. Once the rig is moved off the well will beflow tested for fivedays to confirm gas composition and rate, Ifsufficient quality and quantity of gas isconfirmed through flow testing, a flow line will be run to a small pressure swing adsorption helium plantto remove the helium from the other inert gases.
1. Estimated Formation TopsTops Dakota At surface
Morrison 149'Top of Salt Wash Sand 566' DepletedBase of Salt Wash Sand 595'Entrada 860' Helium PotentialTD (100 feet into Entrada) 960Permitted depth 1,100
2. Estimated Depth and thickness of formations:Name Depth ThicknessSalt Wash (1) 566-595 30Entrada (2) 860-1110 250
Notes: (1) When drilledin the Lansdale Gov #13 well the Salt Wash had 5 psipressure see DP- 2(2) Had 155 psi and attached gas analysis when drilledthrough with the Lansdale Gov, #13 well
3. Pressure Control Equipment:A. Himes Drilling is providing rotating head/diverter and blooey line for the drilling the surface
and down tothe top of the Entrada (intermediate hole). lt is not expected that this intervalwillencounter significant gas. When the Lansdale Gov. #13 was drilledthe Salt Wash zonewas depleted to five psig. In the unlikely event the Salt Wash is not depleted and significantgas is encountered we will be prepared to pump fresh water to killthe zone.
Flatirons Federal #4-1: Drilling Plan Page 1 October 3,
API Well Number: 43019500290000
Eight Point Drilling PlanFlatirons Federal #1-4
September 4, 2012
Project Summary: Flatirons Resources LLC,as operator, intends to drill 1100 ft helium wellon the crestof Harley Dome. The well location is in the middleof three historicaltests on the anticline whichprovide the gas composition and pressure of the Entrada formation. The location will be accessed by anexisting two track road. A trailer mounted rig willbe used to drillthe well. Forty feet of 14 inchconductor pipe will be set, followedby 250 feet of 9-5/8 inch surface casing, and 860 feet of 7 inchcasing to be set above the objective Entrada zone, top setting the zone. Once the cement has beenallowed to set for eight hours the well will be drilledinto the Entrada. After reaching TD the well will beblown dry and the drill pipe will be tripped out of the well. Once the rig is moved off the well will beflow tested for fivedays to confirm gas composition and rate, Ifsufficient quality and quantity of gas isconfirmed through flow testing, a flow line will be run to a small pressure swing adsorption helium plantto remove the helium from the other inert gases.
1. Estimated Formation TopsTops Dakota At surface
Morrison 149'Top of Salt Wash Sand 566' DepletedBase of Salt Wash Sand 595'Entrada 860' Helium PotentialTD (100 feet into Entrada) 960Permitted depth 1,100
2. Estimated Depth and thickness of formations:Name Depth ThicknessSalt Wash (1) 566-595 30Entrada (2) 860-1110 250
Notes: (1) When drilledin the Lansdale Gov #13 well the Salt Wash had 5 psipressure see DP- 2(2) Had 155 psi and attached gas analysis when drilledthrough with the Lansdale Gov, #13 well
3. Pressure Control Equipment:A. Himes Drilling is providing rotating head/diverter and blooey line for the drilling the surface
and down tothe top of the Entrada (intermediate hole). lt is not expected that this intervalwillencounter significant gas. When the Lansdale Gov. #13 was drilledthe Salt Wash zonewas depleted to five psig. In the unlikely event the Salt Wash is not depleted and significantgas is encountered we will be prepared to pump fresh water to killthe zone.
Flatirons Federal #4-1: Drilling Plan Page 1 October 3,
RECEIVED: November 12, 2012
API Well Number: 43019500290000
CONFIDE
NTIAL
API Well Number: 43019500290000
8. After the 7 inch intermediate casing is set, a full opening valve and annular BOP will be putbelow the rotating head. The well will then be drilled to TD.Exhibit DP-11sa diagram of the7-1/16*stack that will be used. Byhaving the fullopening valve under the stack this willallow us to drill into the main pay zone and test the flow,trip out with the drill string andshut the valve and the well will be ready to complete
C. Auxiliaryequipment will include a Kellycockand a full opening TlWvaÍve
4. Casing and Cementing Program:D. Below is the minimum casing program for the proposed well
String Size of Size of Weight Grade Setting Sacks Cement Cementhole casing per Depth Cement Bottom Top (ft)
(inches) (inches) foot (ft) (ft)(#|ft)
Conductor 17 14 55 F-25 40 40 40 0
Surface 12.25 9-5/8 293 H 250 70 250 0Intermediate 8.75 7 17 H 860 110 860 0
E. Allcasing strings below the conductor pipe will be pressure tested to 0.22 psi per foot ofcasingstring length or 500 psi, whichever is greater, but not to exceed 70 percent of theminimum internal yield, If pressure declines more than 10 percent in 30 minutes, correctiveaction shall be taken.
F. Centralizers will be used on the bottom three joints of the surface casing.G. Cement program willbe asfollows:
a. Surface : 70 sacks of cement with appropriate additive; the first ten sacks mixed asa lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixedto yield 2.11 Ft^3/sack and 12.8 3/gal
b. Intermediate: 110 sacks of cement with appropriate additive; the first ten sacksmixed as a lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixed to yield 2.11Ft^3/ sack and 12.8 #/gal
H. After cementing, but before commencing any additional drilling or testing, the casing stringshall be undisturbed until the cement has reached a compressivestrength of at least 500 psiat the shoe. WOC shall be recorded on the driller's log,
5. Mud ProgramThis well will be drilled with air and foam. Offset wells did not have significant water until wellbelow the Entrada. Ifwe are not able to dust because excess water is encountered then we willadd water and soap to the air stream to create stable foam to clean the wellbore.
Flatirons Federal #4-1: Drilling Plan Page 2 October 3,
API Well Number: 43019500290000
8. After the 7 inch intermediate casing is set, a full opening valve and annular BOP will be putbelow the rotating head. The well will then be drilled to TD.Exhibit DP-11sa diagram of the7-1/16*stack that will be used. Byhaving the fullopening valve under the stack this willallow us to drill into the main pay zone and test the flow,trip out with the drill string andshut the valve and the well will be ready to complete
C. Auxiliaryequipment will include a Kellycockand a full opening TlWvaÍve
4. Casing and Cementing Program:D. Below is the minimum casing program for the proposed well
String Size of Size of Weight Grade Setting Sacks Cement Cementhole casing per Depth Cement Bottom Top (ft)
(inches) (inches) foot (ft) (ft)(#|ft)
Conductor 17 14 55 F-25 40 40 40 0
Surface 12.25 9-5/8 293 H 250 70 250 0Intermediate 8.75 7 17 H 860 110 860 0
E. Allcasing strings below the conductor pipe will be pressure tested to 0.22 psi per foot ofcasingstring length or 500 psi, whichever is greater, but not to exceed 70 percent of theminimum internal yield, If pressure declines more than 10 percent in 30 minutes, correctiveaction shall be taken.
F. Centralizers will be used on the bottom three joints of the surface casing.G. Cement program willbe asfollows:
a. Surface : 70 sacks of cement with appropriate additive; the first ten sacks mixed asa lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixedto yield 2.11 Ft^3/sack and 12.8 3/gal
b. Intermediate: 110 sacks of cement with appropriate additive; the first ten sacksmixed as a lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixed to yield 2.11Ft^3/ sack and 12.8 #/gal
H. After cementing, but before commencing any additional drilling or testing, the casing stringshall be undisturbed until the cement has reached a compressivestrength of at least 500 psiat the shoe. WOC shall be recorded on the driller's log,
5. Mud ProgramThis well will be drilled with air and foam. Offset wells did not have significant water until wellbelow the Entrada. Ifwe are not able to dust because excess water is encountered then we willadd water and soap to the air stream to create stable foam to clean the wellbore.
Flatirons Federal #4-1: Drilling Plan Page 2 October 3,
API Well Number: 43019500290000
8. After the 7 inch intermediate casing is set, a full opening valve and annular BOP will be putbelow the rotating head. The well will then be drilled to TD.Exhibit DP-11sa diagram of the7-1/16*stack that will be used. Byhaving the fullopening valve under the stack this willallow us to drill into the main pay zone and test the flow,trip out with the drill string andshut the valve and the well will be ready to complete
C. Auxiliaryequipment will include a Kellycockand a full opening TlWvaÍve
4. Casing and Cementing Program:D. Below is the minimum casing program for the proposed well
String Size of Size of Weight Grade Setting Sacks Cement Cementhole casing per Depth Cement Bottom Top (ft)
(inches) (inches) foot (ft) (ft)(#|ft)
Conductor 17 14 55 F-25 40 40 40 0
Surface 12.25 9-5/8 293 H 250 70 250 0Intermediate 8.75 7 17 H 860 110 860 0
E. Allcasing strings below the conductor pipe will be pressure tested to 0.22 psi per foot ofcasingstring length or 500 psi, whichever is greater, but not to exceed 70 percent of theminimum internal yield, If pressure declines more than 10 percent in 30 minutes, correctiveaction shall be taken.
F. Centralizers will be used on the bottom three joints of the surface casing.G. Cement program willbe asfollows:
a. Surface : 70 sacks of cement with appropriate additive; the first ten sacks mixed asa lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixedto yield 2.11 Ft^3/sack and 12.8 3/gal
b. Intermediate: 110 sacks of cement with appropriate additive; the first ten sacksmixed as a lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixed to yield 2.11Ft^3/ sack and 12.8 #/gal
H. After cementing, but before commencing any additional drilling or testing, the casing stringshall be undisturbed until the cement has reached a compressivestrength of at least 500 psiat the shoe. WOC shall be recorded on the driller's log,
5. Mud ProgramThis well will be drilled with air and foam. Offset wells did not have significant water until wellbelow the Entrada. Ifwe are not able to dust because excess water is encountered then we willadd water and soap to the air stream to create stable foam to clean the wellbore.
Flatirons Federal #4-1: Drilling Plan Page 2 October 3,
API Well Number: 43019500290000
8. After the 7 inch intermediate casing is set, a full opening valve and annular BOP will be putbelow the rotating head. The well will then be drilled to TD.Exhibit DP-11sa diagram of the7-1/16*stack that will be used. Byhaving the fullopening valve under the stack this willallow us to drill into the main pay zone and test the flow,trip out with the drill string andshut the valve and the well will be ready to complete
C. Auxiliaryequipment will include a Kellycockand a full opening TlWvaÍve
4. Casing and Cementing Program:D. Below is the minimum casing program for the proposed well
String Size of Size of Weight Grade Setting Sacks Cement Cementhole casing per Depth Cement Bottom Top (ft)
(inches) (inches) foot (ft) (ft)(#|ft)
Conductor 17 14 55 F-25 40 40 40 0
Surface 12.25 9-5/8 293 H 250 70 250 0Intermediate 8.75 7 17 H 860 110 860 0
E. Allcasing strings below the conductor pipe will be pressure tested to 0.22 psi per foot ofcasingstring length or 500 psi, whichever is greater, but not to exceed 70 percent of theminimum internal yield, If pressure declines more than 10 percent in 30 minutes, correctiveaction shall be taken.
F. Centralizers will be used on the bottom three joints of the surface casing.G. Cement program willbe asfollows:
a. Surface : 70 sacks of cement with appropriate additive; the first ten sacks mixed asa lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixedto yield 2.11 Ft^3/sack and 12.8 3/gal
b. Intermediate: 110 sacks of cement with appropriate additive; the first ten sacksmixed as a lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixed to yield 2.11Ft^3/ sack and 12.8 #/gal
H. After cementing, but before commencing any additional drilling or testing, the casing stringshall be undisturbed until the cement has reached a compressivestrength of at least 500 psiat the shoe. WOC shall be recorded on the driller's log,
5. Mud ProgramThis well will be drilled with air and foam. Offset wells did not have significant water until wellbelow the Entrada. Ifwe are not able to dust because excess water is encountered then we willadd water and soap to the air stream to create stable foam to clean the wellbore.
Flatirons Federal #4-1: Drilling Plan Page 2 October 3,
API Well Number: 43019500290000
8. After the 7 inch intermediate casing is set, a full opening valve and annular BOP will be putbelow the rotating head. The well will then be drilled to TD.Exhibit DP-11sa diagram of the7-1/16*stack that will be used. Byhaving the fullopening valve under the stack this willallow us to drill into the main pay zone and test the flow,trip out with the drill string andshut the valve and the well will be ready to complete
C. Auxiliaryequipment will include a Kellycockand a full opening TlWvaÍve
4. Casing and Cementing Program:D. Below is the minimum casing program for the proposed well
String Size of Size of Weight Grade Setting Sacks Cement Cementhole casing per Depth Cement Bottom Top (ft)
(inches) (inches) foot (ft) (ft)(#|ft)
Conductor 17 14 55 F-25 40 40 40 0
Surface 12.25 9-5/8 293 H 250 70 250 0Intermediate 8.75 7 17 H 860 110 860 0
E. Allcasing strings below the conductor pipe will be pressure tested to 0.22 psi per foot ofcasingstring length or 500 psi, whichever is greater, but not to exceed 70 percent of theminimum internal yield, If pressure declines more than 10 percent in 30 minutes, correctiveaction shall be taken.
F. Centralizers will be used on the bottom three joints of the surface casing.G. Cement program willbe asfollows:
a. Surface : 70 sacks of cement with appropriate additive; the first ten sacks mixed asa lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixedto yield 2.11 Ft^3/sack and 12.8 3/gal
b. Intermediate: 110 sacks of cement with appropriate additive; the first ten sacksmixed as a lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixed to yield 2.11Ft^3/ sack and 12.8 #/gal
H. After cementing, but before commencing any additional drilling or testing, the casing stringshall be undisturbed until the cement has reached a compressivestrength of at least 500 psiat the shoe. WOC shall be recorded on the driller's log,
5. Mud ProgramThis well will be drilled with air and foam. Offset wells did not have significant water until wellbelow the Entrada. Ifwe are not able to dust because excess water is encountered then we willadd water and soap to the air stream to create stable foam to clean the wellbore.
Flatirons Federal #4-1: Drilling Plan Page 2 October 3,
API Well Number: 43019500290000
8. After the 7 inch intermediate casing is set, a full opening valve and annular BOP will be putbelow the rotating head. The well will then be drilled to TD.Exhibit DP-11sa diagram of the7-1/16*stack that will be used. Byhaving the fullopening valve under the stack this willallow us to drill into the main pay zone and test the flow,trip out with the drill string andshut the valve and the well will be ready to complete
C. Auxiliaryequipment will include a Kellycockand a full opening TlWvaÍve
4. Casing and Cementing Program:D. Below is the minimum casing program for the proposed well
String Size of Size of Weight Grade Setting Sacks Cement Cementhole casing per Depth Cement Bottom Top (ft)
(inches) (inches) foot (ft) (ft)(#|ft)
Conductor 17 14 55 F-25 40 40 40 0
Surface 12.25 9-5/8 293 H 250 70 250 0Intermediate 8.75 7 17 H 860 110 860 0
E. Allcasing strings below the conductor pipe will be pressure tested to 0.22 psi per foot ofcasingstring length or 500 psi, whichever is greater, but not to exceed 70 percent of theminimum internal yield, If pressure declines more than 10 percent in 30 minutes, correctiveaction shall be taken.
F. Centralizers will be used on the bottom three joints of the surface casing.G. Cement program willbe asfollows:
a. Surface : 70 sacks of cement with appropriate additive; the first ten sacks mixed asa lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixedto yield 2.11 Ft^3/sack and 12.8 3/gal
b. Intermediate: 110 sacks of cement with appropriate additive; the first ten sacksmixed as a lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixed to yield 2.11Ft^3/ sack and 12.8 #/gal
H. After cementing, but before commencing any additional drilling or testing, the casing stringshall be undisturbed until the cement has reached a compressivestrength of at least 500 psiat the shoe. WOC shall be recorded on the driller's log,
5. Mud ProgramThis well will be drilled with air and foam. Offset wells did not have significant water until wellbelow the Entrada. Ifwe are not able to dust because excess water is encountered then we willadd water and soap to the air stream to create stable foam to clean the wellbore.
Flatirons Federal #4-1: Drilling Plan Page 2 October 3,
API Well Number: 43019500290000
8. After the 7 inch intermediate casing is set, a full opening valve and annular BOP will be putbelow the rotating head. The well will then be drilled to TD.Exhibit DP-11sa diagram of the7-1/16*stack that will be used. Byhaving the fullopening valve under the stack this willallow us to drill into the main pay zone and test the flow,trip out with the drill string andshut the valve and the well will be ready to complete
C. Auxiliaryequipment will include a Kellycockand a full opening TlWvaÍve
4. Casing and Cementing Program:D. Below is the minimum casing program for the proposed well
String Size of Size of Weight Grade Setting Sacks Cement Cementhole casing per Depth Cement Bottom Top (ft)
(inches) (inches) foot (ft) (ft)(#|ft)
Conductor 17 14 55 F-25 40 40 40 0
Surface 12.25 9-5/8 293 H 250 70 250 0Intermediate 8.75 7 17 H 860 110 860 0
E. Allcasing strings below the conductor pipe will be pressure tested to 0.22 psi per foot ofcasingstring length or 500 psi, whichever is greater, but not to exceed 70 percent of theminimum internal yield, If pressure declines more than 10 percent in 30 minutes, correctiveaction shall be taken.
F. Centralizers will be used on the bottom three joints of the surface casing.G. Cement program willbe asfollows:
a. Surface : 70 sacks of cement with appropriate additive; the first ten sacks mixed asa lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixedto yield 2.11 Ft^3/sack and 12.8 3/gal
b. Intermediate: 110 sacks of cement with appropriate additive; the first ten sacksmixed as a lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixed to yield 2.11Ft^3/ sack and 12.8 #/gal
H. After cementing, but before commencing any additional drilling or testing, the casing stringshall be undisturbed until the cement has reached a compressivestrength of at least 500 psiat the shoe. WOC shall be recorded on the driller's log,
5. Mud ProgramThis well will be drilled with air and foam. Offset wells did not have significant water until wellbelow the Entrada. Ifwe are not able to dust because excess water is encountered then we willadd water and soap to the air stream to create stable foam to clean the wellbore.
Flatirons Federal #4-1: Drilling Plan Page 2 October 3,
API Well Number: 43019500290000
8. After the 7 inch intermediate casing is set, a full opening valve and annular BOP will be putbelow the rotating head. The well will then be drilled to TD.Exhibit DP-11sa diagram of the7-1/16*stack that will be used. Byhaving the fullopening valve under the stack this willallow us to drill into the main pay zone and test the flow,trip out with the drill string andshut the valve and the well will be ready to complete
C. Auxiliaryequipment will include a Kellycockand a full opening TlWvaÍve
4. Casing and Cementing Program:D. Below is the minimum casing program for the proposed well
String Size of Size of Weight Grade Setting Sacks Cement Cementhole casing per Depth Cement Bottom Top (ft)
(inches) (inches) foot (ft) (ft)(#|ft)
Conductor 17 14 55 F-25 40 40 40 0
Surface 12.25 9-5/8 293 H 250 70 250 0Intermediate 8.75 7 17 H 860 110 860 0
E. Allcasing strings below the conductor pipe will be pressure tested to 0.22 psi per foot ofcasingstring length or 500 psi, whichever is greater, but not to exceed 70 percent of theminimum internal yield, If pressure declines more than 10 percent in 30 minutes, correctiveaction shall be taken.
F. Centralizers will be used on the bottom three joints of the surface casing.G. Cement program willbe asfollows:
a. Surface : 70 sacks of cement with appropriate additive; the first ten sacks mixed asa lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixedto yield 2.11 Ft^3/sack and 12.8 3/gal
b. Intermediate: 110 sacks of cement with appropriate additive; the first ten sacksmixed as a lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixed to yield 2.11Ft^3/ sack and 12.8 #/gal
H. After cementing, but before commencing any additional drilling or testing, the casing stringshall be undisturbed until the cement has reached a compressivestrength of at least 500 psiat the shoe. WOC shall be recorded on the driller's log,
5. Mud ProgramThis well will be drilled with air and foam. Offset wells did not have significant water until wellbelow the Entrada. Ifwe are not able to dust because excess water is encountered then we willadd water and soap to the air stream to create stable foam to clean the wellbore.
Flatirons Federal #4-1: Drilling Plan Page 2 October 3,
API Well Number: 43019500290000
8. After the 7 inch intermediate casing is set, a full opening valve and annular BOP will be putbelow the rotating head. The well will then be drilled to TD.Exhibit DP-11sa diagram of the7-1/16*stack that will be used. Byhaving the fullopening valve under the stack this willallow us to drill into the main pay zone and test the flow,trip out with the drill string andshut the valve and the well will be ready to complete
C. Auxiliaryequipment will include a Kellycockand a full opening TlWvaÍve
4. Casing and Cementing Program:D. Below is the minimum casing program for the proposed well
String Size of Size of Weight Grade Setting Sacks Cement Cementhole casing per Depth Cement Bottom Top (ft)
(inches) (inches) foot (ft) (ft)(#|ft)
Conductor 17 14 55 F-25 40 40 40 0
Surface 12.25 9-5/8 293 H 250 70 250 0Intermediate 8.75 7 17 H 860 110 860 0
E. Allcasing strings below the conductor pipe will be pressure tested to 0.22 psi per foot ofcasingstring length or 500 psi, whichever is greater, but not to exceed 70 percent of theminimum internal yield, If pressure declines more than 10 percent in 30 minutes, correctiveaction shall be taken.
F. Centralizers will be used on the bottom three joints of the surface casing.G. Cement program willbe asfollows:
a. Surface : 70 sacks of cement with appropriate additive; the first ten sacks mixed asa lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixedto yield 2.11 Ft^3/sack and 12.8 3/gal
b. Intermediate: 110 sacks of cement with appropriate additive; the first ten sacksmixed as a lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixed to yield 2.11Ft^3/ sack and 12.8 #/gal
H. After cementing, but before commencing any additional drilling or testing, the casing stringshall be undisturbed until the cement has reached a compressivestrength of at least 500 psiat the shoe. WOC shall be recorded on the driller's log,
5. Mud ProgramThis well will be drilled with air and foam. Offset wells did not have significant water until wellbelow the Entrada. Ifwe are not able to dust because excess water is encountered then we willadd water and soap to the air stream to create stable foam to clean the wellbore.
Flatirons Federal #4-1: Drilling Plan Page 2 October 3,
API Well Number: 43019500290000
8. After the 7 inch intermediate casing is set, a full opening valve and annular BOP will be putbelow the rotating head. The well will then be drilled to TD.Exhibit DP-11sa diagram of the7-1/16*stack that will be used. Byhaving the fullopening valve under the stack this willallow us to drill into the main pay zone and test the flow,trip out with the drill string andshut the valve and the well will be ready to complete
C. Auxiliaryequipment will include a Kellycockand a full opening TlWvaÍve
4. Casing and Cementing Program:D. Below is the minimum casing program for the proposed well
String Size of Size of Weight Grade Setting Sacks Cement Cementhole casing per Depth Cement Bottom Top (ft)
(inches) (inches) foot (ft) (ft)(#|ft)
Conductor 17 14 55 F-25 40 40 40 0
Surface 12.25 9-5/8 293 H 250 70 250 0Intermediate 8.75 7 17 H 860 110 860 0
E. Allcasing strings below the conductor pipe will be pressure tested to 0.22 psi per foot ofcasingstring length or 500 psi, whichever is greater, but not to exceed 70 percent of theminimum internal yield, If pressure declines more than 10 percent in 30 minutes, correctiveaction shall be taken.
F. Centralizers will be used on the bottom three joints of the surface casing.G. Cement program willbe asfollows:
a. Surface : 70 sacks of cement with appropriate additive; the first ten sacks mixed asa lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixedto yield 2.11 Ft^3/sack and 12.8 3/gal
b. Intermediate: 110 sacks of cement with appropriate additive; the first ten sacksmixed as a lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixed to yield 2.11Ft^3/ sack and 12.8 #/gal
H. After cementing, but before commencing any additional drilling or testing, the casing stringshall be undisturbed until the cement has reached a compressivestrength of at least 500 psiat the shoe. WOC shall be recorded on the driller's log,
5. Mud ProgramThis well will be drilled with air and foam. Offset wells did not have significant water until wellbelow the Entrada. Ifwe are not able to dust because excess water is encountered then we willadd water and soap to the air stream to create stable foam to clean the wellbore.
Flatirons Federal #4-1: Drilling Plan Page 2 October 3,
API Well Number: 43019500290000
8. After the 7 inch intermediate casing is set, a full opening valve and annular BOP will be putbelow the rotating head. The well will then be drilled to TD.Exhibit DP-11sa diagram of the7-1/16*stack that will be used. Byhaving the fullopening valve under the stack this willallow us to drill into the main pay zone and test the flow,trip out with the drill string andshut the valve and the well will be ready to complete
C. Auxiliaryequipment will include a Kellycockand a full opening TlWvaÍve
4. Casing and Cementing Program:D. Below is the minimum casing program for the proposed well
String Size of Size of Weight Grade Setting Sacks Cement Cementhole casing per Depth Cement Bottom Top (ft)
(inches) (inches) foot (ft) (ft)(#|ft)
Conductor 17 14 55 F-25 40 40 40 0
Surface 12.25 9-5/8 293 H 250 70 250 0Intermediate 8.75 7 17 H 860 110 860 0
E. Allcasing strings below the conductor pipe will be pressure tested to 0.22 psi per foot ofcasingstring length or 500 psi, whichever is greater, but not to exceed 70 percent of theminimum internal yield, If pressure declines more than 10 percent in 30 minutes, correctiveaction shall be taken.
F. Centralizers will be used on the bottom three joints of the surface casing.G. Cement program willbe asfollows:
a. Surface : 70 sacks of cement with appropriate additive; the first ten sacks mixed asa lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixedto yield 2.11 Ft^3/sack and 12.8 3/gal
b. Intermediate: 110 sacks of cement with appropriate additive; the first ten sacksmixed as a lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixed to yield 2.11Ft^3/ sack and 12.8 #/gal
H. After cementing, but before commencing any additional drilling or testing, the casing stringshall be undisturbed until the cement has reached a compressivestrength of at least 500 psiat the shoe. WOC shall be recorded on the driller's log,
5. Mud ProgramThis well will be drilled with air and foam. Offset wells did not have significant water until wellbelow the Entrada. Ifwe are not able to dust because excess water is encountered then we willadd water and soap to the air stream to create stable foam to clean the wellbore.
Flatirons Federal #4-1: Drilling Plan Page 2 October 3,
API Well Number: 43019500290000
8. After the 7 inch intermediate casing is set, a full opening valve and annular BOP will be putbelow the rotating head. The well will then be drilled to TD.Exhibit DP-11sa diagram of the7-1/16*stack that will be used. Byhaving the fullopening valve under the stack this willallow us to drill into the main pay zone and test the flow,trip out with the drill string andshut the valve and the well will be ready to complete
C. Auxiliaryequipment will include a Kellycockand a full opening TlWvaÍve
4. Casing and Cementing Program:D. Below is the minimum casing program for the proposed well
String Size of Size of Weight Grade Setting Sacks Cement Cementhole casing per Depth Cement Bottom Top (ft)
(inches) (inches) foot (ft) (ft)(#|ft)
Conductor 17 14 55 F-25 40 40 40 0
Surface 12.25 9-5/8 293 H 250 70 250 0Intermediate 8.75 7 17 H 860 110 860 0
E. Allcasing strings below the conductor pipe will be pressure tested to 0.22 psi per foot ofcasingstring length or 500 psi, whichever is greater, but not to exceed 70 percent of theminimum internal yield, If pressure declines more than 10 percent in 30 minutes, correctiveaction shall be taken.
F. Centralizers will be used on the bottom three joints of the surface casing.G. Cement program willbe asfollows:
a. Surface : 70 sacks of cement with appropriate additive; the first ten sacks mixed asa lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixedto yield 2.11 Ft^3/sack and 12.8 3/gal
b. Intermediate: 110 sacks of cement with appropriate additive; the first ten sacksmixed as a lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixed to yield 2.11Ft^3/ sack and 12.8 #/gal
H. After cementing, but before commencing any additional drilling or testing, the casing stringshall be undisturbed until the cement has reached a compressivestrength of at least 500 psiat the shoe. WOC shall be recorded on the driller's log,
5. Mud ProgramThis well will be drilled with air and foam. Offset wells did not have significant water until wellbelow the Entrada. Ifwe are not able to dust because excess water is encountered then we willadd water and soap to the air stream to create stable foam to clean the wellbore.
Flatirons Federal #4-1: Drilling Plan Page 2 October 3,
API Well Number: 43019500290000
8. After the 7 inch intermediate casing is set, a full opening valve and annular BOP will be putbelow the rotating head. The well will then be drilled to TD.Exhibit DP-11sa diagram of the7-1/16*stack that will be used. Byhaving the fullopening valve under the stack this willallow us to drill into the main pay zone and test the flow,trip out with the drill string andshut the valve and the well will be ready to complete
C. Auxiliaryequipment will include a Kellycockand a full opening TlWvaÍve
4. Casing and Cementing Program:D. Below is the minimum casing program for the proposed well
String Size of Size of Weight Grade Setting Sacks Cement Cementhole casing per Depth Cement Bottom Top (ft)
(inches) (inches) foot (ft) (ft)(#|ft)
Conductor 17 14 55 F-25 40 40 40 0
Surface 12.25 9-5/8 293 H 250 70 250 0Intermediate 8.75 7 17 H 860 110 860 0
E. Allcasing strings below the conductor pipe will be pressure tested to 0.22 psi per foot ofcasingstring length or 500 psi, whichever is greater, but not to exceed 70 percent of theminimum internal yield, If pressure declines more than 10 percent in 30 minutes, correctiveaction shall be taken.
F. Centralizers will be used on the bottom three joints of the surface casing.G. Cement program willbe asfollows:
a. Surface : 70 sacks of cement with appropriate additive; the first ten sacks mixed asa lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixedto yield 2.11 Ft^3/sack and 12.8 3/gal
b. Intermediate: 110 sacks of cement with appropriate additive; the first ten sacksmixed as a lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixed to yield 2.11Ft^3/ sack and 12.8 #/gal
H. After cementing, but before commencing any additional drilling or testing, the casing stringshall be undisturbed until the cement has reached a compressivestrength of at least 500 psiat the shoe. WOC shall be recorded on the driller's log,
5. Mud ProgramThis well will be drilled with air and foam. Offset wells did not have significant water until wellbelow the Entrada. Ifwe are not able to dust because excess water is encountered then we willadd water and soap to the air stream to create stable foam to clean the wellbore.
Flatirons Federal #4-1: Drilling Plan Page 2 October 3,
API Well Number: 43019500290000
8. After the 7 inch intermediate casing is set, a full opening valve and annular BOP will be putbelow the rotating head. The well will then be drilled to TD.Exhibit DP-11sa diagram of the7-1/16*stack that will be used. Byhaving the fullopening valve under the stack this willallow us to drill into the main pay zone and test the flow,trip out with the drill string andshut the valve and the well will be ready to complete
C. Auxiliaryequipment will include a Kellycockand a full opening TlWvaÍve
4. Casing and Cementing Program:D. Below is the minimum casing program for the proposed well
String Size of Size of Weight Grade Setting Sacks Cement Cementhole casing per Depth Cement Bottom Top (ft)
(inches) (inches) foot (ft) (ft)(#|ft)
Conductor 17 14 55 F-25 40 40 40 0
Surface 12.25 9-5/8 293 H 250 70 250 0Intermediate 8.75 7 17 H 860 110 860 0
E. Allcasing strings below the conductor pipe will be pressure tested to 0.22 psi per foot ofcasingstring length or 500 psi, whichever is greater, but not to exceed 70 percent of theminimum internal yield, If pressure declines more than 10 percent in 30 minutes, correctiveaction shall be taken.
F. Centralizers will be used on the bottom three joints of the surface casing.G. Cement program willbe asfollows:
a. Surface : 70 sacks of cement with appropriate additive; the first ten sacks mixed asa lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixedto yield 2.11 Ft^3/sack and 12.8 3/gal
b. Intermediate: 110 sacks of cement with appropriate additive; the first ten sacksmixed as a lead at 2.38 Ft^3/sk and 12.3 #/gal, followed 60 sacks mixed to yield 2.11Ft^3/ sack and 12.8 #/gal
H. After cementing, but before commencing any additional drilling or testing, the casing stringshall be undisturbed until the cement has reached a compressivestrength of at least 500 psiat the shoe. WOC shall be recorded on the driller's log,
5. Mud ProgramThis well will be drilled with air and foam. Offset wells did not have significant water until wellbelow the Entrada. Ifwe are not able to dust because excess water is encountered then we willadd water and soap to the air stream to create stable foam to clean the wellbore.
Flatirons Federal #4-1: Drilling Plan Page 2 October 3,
RECEIVED: November 12, 2012
API Well Number: 43019500290000
CONFIDE
NTIAL
API Well Number: 43019500290000
Our blooie line as shown will be 40 feet long and aimed into the pit, We will keep 120 bbis of
fresh water on site at all times to killthe well, which is more than twice the volume of the holeat total depth. From the Salt Wash zone to TD we will keep a smudge pot at the end of theblooie line to ignite any combustible gas that is encountered. We will be set up to spray freshwater into the blooie lineto suppress any dust that is created.
6. Testing, Coring, and Logging
As the well is drilling we willshut down at the indication of anygas entry into the wellbore tomeasure the_flowingrate, If significant gas is encountered we will shut down to measure a flowrate, get a gas sample and shut in pressure.
No cores will be taken. Prior to running intermediate casing a gamma ray and resistivitylog willbe run.
7. Anticipated Drilling Conditions:Based on the Lansdale Gov. #13 well drilled 350 feet east of this location in May of 1968, theSalt Wash zone is depleted to 5 psi and the Entrada is 155 #. Attached as DP-2 are gas analysesfor both zones. The Entrada is a non combustible gas mixture with only 8.5% methane and6.47% helium, and 83.8% Nitrogen. The Salt Wash zone of the Morrison is similar gas with
14.8% methane and only 2.4% helium.
8. OperationsIt is anticipated that the well willspud within 60 days of approved permit, it will take a week toten days to drilL Once the well is drilled it will be ready for the testing. We willrun a five daystep rated flowtest to determine reservoir parameters. Based on the flowtesting, the decisionwill be made to run a flow line and install the hellum separation plant or plug and abandon thewelL It is estimated that the flowlinewilltake a week to ten daysto install and the plantinstallation willtake two weeks. From spud to first production of separated helium isanticipated to be 45-60 days.
Flatirons Federal #4-1: Drilling Plan Page 3 October 3,
API Well Number: 43019500290000
Our blooie line as shown will be 40 feet long and aimed into the pit, We will keep 120 bbis of
fresh water on site at all times to killthe well, which is more than twice the volume of the holeat total depth. From the Salt Wash zone to TD we will keep a smudge pot at the end of theblooie line to ignite any combustible gas that is encountered. We will be set up to spray freshwater into the blooie lineto suppress any dust that is created.
6. Testing, Coring, and Logging
As the well is drilling we willshut down at the indication of anygas entry into the wellbore tomeasure the_flowingrate, If significant gas is encountered we will shut down to measure a flowrate, get a gas sample and shut in pressure.
No cores will be taken. Prior to running intermediate casing a gamma ray and resistivitylog willbe run.
7. Anticipated Drilling Conditions:Based on the Lansdale Gov. #13 well drilled 350 feet east of this location in May of 1968, theSalt Wash zone is depleted to 5 psi and the Entrada is 155 #. Attached as DP-2 are gas analysesfor both zones. The Entrada is a non combustible gas mixture with only 8.5% methane and6.47% helium, and 83.8% Nitrogen. The Salt Wash zone of the Morrison is similar gas with
14.8% methane and only 2.4% helium.
8. OperationsIt is anticipated that the well willspud within 60 days of approved permit, it will take a week toten days to drilL Once the well is drilled it will be ready for the testing. We willrun a five daystep rated flowtest to determine reservoir parameters. Based on the flowtesting, the decisionwill be made to run a flow line and install the hellum separation plant or plug and abandon thewelL It is estimated that the flowlinewilltake a week to ten daysto install and the plantinstallation willtake two weeks. From spud to first production of separated helium isanticipated to be 45-60 days.
Flatirons Federal #4-1: Drilling Plan Page 3 October 3,
API Well Number: 43019500290000
Our blooie line as shown will be 40 feet long and aimed into the pit, We will keep 120 bbis of
fresh water on site at all times to killthe well, which is more than twice the volume of the holeat total depth. From the Salt Wash zone to TD we will keep a smudge pot at the end of theblooie line to ignite any combustible gas that is encountered. We will be set up to spray freshwater into the blooie lineto suppress any dust that is created.
6. Testing, Coring, and Logging
As the well is drilling we willshut down at the indication of anygas entry into the wellbore tomeasure the_flowingrate, If significant gas is encountered we will shut down to measure a flowrate, get a gas sample and shut in pressure.
No cores will be taken. Prior to running intermediate casing a gamma ray and resistivitylog willbe run.
7. Anticipated Drilling Conditions:Based on the Lansdale Gov. #13 well drilled 350 feet east of this location in May of 1968, theSalt Wash zone is depleted to 5 psi and the Entrada is 155 #. Attached as DP-2 are gas analysesfor both zones. The Entrada is a non combustible gas mixture with only 8.5% methane and6.47% helium, and 83.8% Nitrogen. The Salt Wash zone of the Morrison is similar gas with
14.8% methane and only 2.4% helium.
8. OperationsIt is anticipated that the well willspud within 60 days of approved permit, it will take a week toten days to drilL Once the well is drilled it will be ready for the testing. We willrun a five daystep rated flowtest to determine reservoir parameters. Based on the flowtesting, the decisionwill be made to run a flow line and install the hellum separation plant or plug and abandon thewelL It is estimated that the flowlinewilltake a week to ten daysto install and the plantinstallation willtake two weeks. From spud to first production of separated helium isanticipated to be 45-60 days.
Flatirons Federal #4-1: Drilling Plan Page 3 October 3,
API Well Number: 43019500290000
Our blooie line as shown will be 40 feet long and aimed into the pit, We will keep 120 bbis of
fresh water on site at all times to killthe well, which is more than twice the volume of the holeat total depth. From the Salt Wash zone to TD we will keep a smudge pot at the end of theblooie line to ignite any combustible gas that is encountered. We will be set up to spray freshwater into the blooie lineto suppress any dust that is created.
6. Testing, Coring, and Logging
As the well is drilling we willshut down at the indication of anygas entry into the wellbore tomeasure the_flowingrate, If significant gas is encountered we will shut down to measure a flowrate, get a gas sample and shut in pressure.
No cores will be taken. Prior to running intermediate casing a gamma ray and resistivitylog willbe run.
7. Anticipated Drilling Conditions:Based on the Lansdale Gov. #13 well drilled 350 feet east of this location in May of 1968, theSalt Wash zone is depleted to 5 psi and the Entrada is 155 #. Attached as DP-2 are gas analysesfor both zones. The Entrada is a non combustible gas mixture with only 8.5% methane and6.47% helium, and 83.8% Nitrogen. The Salt Wash zone of the Morrison is similar gas with
14.8% methane and only 2.4% helium.
8. OperationsIt is anticipated that the well willspud within 60 days of approved permit, it will take a week toten days to drilL Once the well is drilled it will be ready for the testing. We willrun a five daystep rated flowtest to determine reservoir parameters. Based on the flowtesting, the decisionwill be made to run a flow line and install the hellum separation plant or plug and abandon thewelL It is estimated that the flowlinewilltake a week to ten daysto install and the plantinstallation willtake two weeks. From spud to first production of separated helium isanticipated to be 45-60 days.
Flatirons Federal #4-1: Drilling Plan Page 3 October 3,
API Well Number: 43019500290000
Our blooie line as shown will be 40 feet long and aimed into the pit, We will keep 120 bbis of
fresh water on site at all times to killthe well, which is more than twice the volume of the holeat total depth. From the Salt Wash zone to TD we will keep a smudge pot at the end of theblooie line to ignite any combustible gas that is encountered. We will be set up to spray freshwater into the blooie lineto suppress any dust that is created.
6. Testing, Coring, and Logging
As the well is drilling we willshut down at the indication of anygas entry into the wellbore tomeasure the_flowingrate, If significant gas is encountered we will shut down to measure a flowrate, get a gas sample and shut in pressure.
No cores will be taken. Prior to running intermediate casing a gamma ray and resistivitylog willbe run.
7. Anticipated Drilling Conditions:Based on the Lansdale Gov. #13 well drilled 350 feet east of this location in May of 1968, theSalt Wash zone is depleted to 5 psi and the Entrada is 155 #. Attached as DP-2 are gas analysesfor both zones. The Entrada is a non combustible gas mixture with only 8.5% methane and6.47% helium, and 83.8% Nitrogen. The Salt Wash zone of the Morrison is similar gas with
14.8% methane and only 2.4% helium.
8. OperationsIt is anticipated that the well willspud within 60 days of approved permit, it will take a week toten days to drilL Once the well is drilled it will be ready for the testing. We willrun a five daystep rated flowtest to determine reservoir parameters. Based on the flowtesting, the decisionwill be made to run a flow line and install the hellum separation plant or plug and abandon thewelL It is estimated that the flowlinewilltake a week to ten daysto install and the plantinstallation willtake two weeks. From spud to first production of separated helium isanticipated to be 45-60 days.
Flatirons Federal #4-1: Drilling Plan Page 3 October 3,
API Well Number: 43019500290000
Our blooie line as shown will be 40 feet long and aimed into the pit, We will keep 120 bbis of
fresh water on site at all times to killthe well, which is more than twice the volume of the holeat total depth. From the Salt Wash zone to TD we will keep a smudge pot at the end of theblooie line to ignite any combustible gas that is encountered. We will be set up to spray freshwater into the blooie lineto suppress any dust that is created.
6. Testing, Coring, and Logging
As the well is drilling we willshut down at the indication of anygas entry into the wellbore tomeasure the_flowingrate, If significant gas is encountered we will shut down to measure a flowrate, get a gas sample and shut in pressure.
No cores will be taken. Prior to running intermediate casing a gamma ray and resistivitylog willbe run.
7. Anticipated Drilling Conditions:Based on the Lansdale Gov. #13 well drilled 350 feet east of this location in May of 1968, theSalt Wash zone is depleted to 5 psi and the Entrada is 155 #. Attached as DP-2 are gas analysesfor both zones. The Entrada is a non combustible gas mixture with only 8.5% methane and6.47% helium, and 83.8% Nitrogen. The Salt Wash zone of the Morrison is similar gas with
14.8% methane and only 2.4% helium.
8. OperationsIt is anticipated that the well willspud within 60 days of approved permit, it will take a week toten days to drilL Once the well is drilled it will be ready for the testing. We willrun a five daystep rated flowtest to determine reservoir parameters. Based on the flowtesting, the decisionwill be made to run a flow line and install the hellum separation plant or plug and abandon thewelL It is estimated that the flowlinewilltake a week to ten daysto install and the plantinstallation willtake two weeks. From spud to first production of separated helium isanticipated to be 45-60 days.
Flatirons Federal #4-1: Drilling Plan Page 3 October 3,
API Well Number: 43019500290000
Our blooie line as shown will be 40 feet long and aimed into the pit, We will keep 120 bbis of
fresh water on site at all times to killthe well, which is more than twice the volume of the holeat total depth. From the Salt Wash zone to TD we will keep a smudge pot at the end of theblooie line to ignite any combustible gas that is encountered. We will be set up to spray freshwater into the blooie lineto suppress any dust that is created.
6. Testing, Coring, and Logging
As the well is drilling we willshut down at the indication of anygas entry into the wellbore tomeasure the_flowingrate, If significant gas is encountered we will shut down to measure a flowrate, get a gas sample and shut in pressure.
No cores will be taken. Prior to running intermediate casing a gamma ray and resistivitylog willbe run.
7. Anticipated Drilling Conditions:Based on the Lansdale Gov. #13 well drilled 350 feet east of this location in May of 1968, theSalt Wash zone is depleted to 5 psi and the Entrada is 155 #. Attached as DP-2 are gas analysesfor both zones. The Entrada is a non combustible gas mixture with only 8.5% methane and6.47% helium, and 83.8% Nitrogen. The Salt Wash zone of the Morrison is similar gas with
14.8% methane and only 2.4% helium.
8. OperationsIt is anticipated that the well willspud within 60 days of approved permit, it will take a week toten days to drilL Once the well is drilled it will be ready for the testing. We willrun a five daystep rated flowtest to determine reservoir parameters. Based on the flowtesting, the decisionwill be made to run a flow line and install the hellum separation plant or plug and abandon thewelL It is estimated that the flowlinewilltake a week to ten daysto install and the plantinstallation willtake two weeks. From spud to first production of separated helium isanticipated to be 45-60 days.
Flatirons Federal #4-1: Drilling Plan Page 3 October 3,
API Well Number: 43019500290000
Our blooie line as shown will be 40 feet long and aimed into the pit, We will keep 120 bbis of
fresh water on site at all times to killthe well, which is more than twice the volume of the holeat total depth. From the Salt Wash zone to TD we will keep a smudge pot at the end of theblooie line to ignite any combustible gas that is encountered. We will be set up to spray freshwater into the blooie lineto suppress any dust that is created.
6. Testing, Coring, and Logging
As the well is drilling we willshut down at the indication of anygas entry into the wellbore tomeasure the_flowingrate, If significant gas is encountered we will shut down to measure a flowrate, get a gas sample and shut in pressure.
No cores will be taken. Prior to running intermediate casing a gamma ray and resistivitylog willbe run.
7. Anticipated Drilling Conditions:Based on the Lansdale Gov. #13 well drilled 350 feet east of this location in May of 1968, theSalt Wash zone is depleted to 5 psi and the Entrada is 155 #. Attached as DP-2 are gas analysesfor both zones. The Entrada is a non combustible gas mixture with only 8.5% methane and6.47% helium, and 83.8% Nitrogen. The Salt Wash zone of the Morrison is similar gas with
14.8% methane and only 2.4% helium.
8. OperationsIt is anticipated that the well willspud within 60 days of approved permit, it will take a week toten days to drilL Once the well is drilled it will be ready for the testing. We willrun a five daystep rated flowtest to determine reservoir parameters. Based on the flowtesting, the decisionwill be made to run a flow line and install the hellum separation plant or plug and abandon thewelL It is estimated that the flowlinewilltake a week to ten daysto install and the plantinstallation willtake two weeks. From spud to first production of separated helium isanticipated to be 45-60 days.
Flatirons Federal #4-1: Drilling Plan Page 3 October 3,
API Well Number: 43019500290000
Our blooie line as shown will be 40 feet long and aimed into the pit, We will keep 120 bbis of
fresh water on site at all times to killthe well, which is more than twice the volume of the holeat total depth. From the Salt Wash zone to TD we will keep a smudge pot at the end of theblooie line to ignite any combustible gas that is encountered. We will be set up to spray freshwater into the blooie lineto suppress any dust that is created.
6. Testing, Coring, and Logging
As the well is drilling we willshut down at the indication of anygas entry into the wellbore tomeasure the_flowingrate, If significant gas is encountered we will shut down to measure a flowrate, get a gas sample and shut in pressure.
No cores will be taken. Prior to running intermediate casing a gamma ray and resistivitylog willbe run.
7. Anticipated Drilling Conditions:Based on the Lansdale Gov. #13 well drilled 350 feet east of this location in May of 1968, theSalt Wash zone is depleted to 5 psi and the Entrada is 155 #. Attached as DP-2 are gas analysesfor both zones. The Entrada is a non combustible gas mixture with only 8.5% methane and6.47% helium, and 83.8% Nitrogen. The Salt Wash zone of the Morrison is similar gas with
14.8% methane and only 2.4% helium.
8. OperationsIt is anticipated that the well willspud within 60 days of approved permit, it will take a week toten days to drilL Once the well is drilled it will be ready for the testing. We willrun a five daystep rated flowtest to determine reservoir parameters. Based on the flowtesting, the decisionwill be made to run a flow line and install the hellum separation plant or plug and abandon thewelL It is estimated that the flowlinewilltake a week to ten daysto install and the plantinstallation willtake two weeks. From spud to first production of separated helium isanticipated to be 45-60 days.
Flatirons Federal #4-1: Drilling Plan Page 3 October 3,
API Well Number: 43019500290000
Our blooie line as shown will be 40 feet long and aimed into the pit, We will keep 120 bbis of
fresh water on site at all times to killthe well, which is more than twice the volume of the holeat total depth. From the Salt Wash zone to TD we will keep a smudge pot at the end of theblooie line to ignite any combustible gas that is encountered. We will be set up to spray freshwater into the blooie lineto suppress any dust that is created.
6. Testing, Coring, and Logging
As the well is drilling we willshut down at the indication of anygas entry into the wellbore tomeasure the_flowingrate, If significant gas is encountered we will shut down to measure a flowrate, get a gas sample and shut in pressure.
No cores will be taken. Prior to running intermediate casing a gamma ray and resistivitylog willbe run.
7. Anticipated Drilling Conditions:Based on the Lansdale Gov. #13 well drilled 350 feet east of this location in May of 1968, theSalt Wash zone is depleted to 5 psi and the Entrada is 155 #. Attached as DP-2 are gas analysesfor both zones. The Entrada is a non combustible gas mixture with only 8.5% methane and6.47% helium, and 83.8% Nitrogen. The Salt Wash zone of the Morrison is similar gas with
14.8% methane and only 2.4% helium.
8. OperationsIt is anticipated that the well willspud within 60 days of approved permit, it will take a week toten days to drilL Once the well is drilled it will be ready for the testing. We willrun a five daystep rated flowtest to determine reservoir parameters. Based on the flowtesting, the decisionwill be made to run a flow line and install the hellum separation plant or plug and abandon thewelL It is estimated that the flowlinewilltake a week to ten daysto install and the plantinstallation willtake two weeks. From spud to first production of separated helium isanticipated to be 45-60 days.
Flatirons Federal #4-1: Drilling Plan Page 3 October 3,
API Well Number: 43019500290000
Our blooie line as shown will be 40 feet long and aimed into the pit, We will keep 120 bbis of
fresh water on site at all times to killthe well, which is more than twice the volume of the holeat total depth. From the Salt Wash zone to TD we will keep a smudge pot at the end of theblooie line to ignite any combustible gas that is encountered. We will be set up to spray freshwater into the blooie lineto suppress any dust that is created.
6. Testing, Coring, and Logging
As the well is drilling we willshut down at the indication of anygas entry into the wellbore tomeasure the_flowingrate, If significant gas is encountered we will shut down to measure a flowrate, get a gas sample and shut in pressure.
No cores will be taken. Prior to running intermediate casing a gamma ray and resistivitylog willbe run.
7. Anticipated Drilling Conditions:Based on the Lansdale Gov. #13 well drilled 350 feet east of this location in May of 1968, theSalt Wash zone is depleted to 5 psi and the Entrada is 155 #. Attached as DP-2 are gas analysesfor both zones. The Entrada is a non combustible gas mixture with only 8.5% methane and6.47% helium, and 83.8% Nitrogen. The Salt Wash zone of the Morrison is similar gas with
14.8% methane and only 2.4% helium.
8. OperationsIt is anticipated that the well willspud within 60 days of approved permit, it will take a week toten days to drilL Once the well is drilled it will be ready for the testing. We willrun a five daystep rated flowtest to determine reservoir parameters. Based on the flowtesting, the decisionwill be made to run a flow line and install the hellum separation plant or plug and abandon thewelL It is estimated that the flowlinewilltake a week to ten daysto install and the plantinstallation willtake two weeks. From spud to first production of separated helium isanticipated to be 45-60 days.
Flatirons Federal #4-1: Drilling Plan Page 3 October 3,
API Well Number: 43019500290000
Our blooie line as shown will be 40 feet long and aimed into the pit, We will keep 120 bbis of
fresh water on site at all times to killthe well, which is more than twice the volume of the holeat total depth. From the Salt Wash zone to TD we will keep a smudge pot at the end of theblooie line to ignite any combustible gas that is encountered. We will be set up to spray freshwater into the blooie lineto suppress any dust that is created.
6. Testing, Coring, and Logging
As the well is drilling we willshut down at the indication of anygas entry into the wellbore tomeasure the_flowingrate, If significant gas is encountered we will shut down to measure a flowrate, get a gas sample and shut in pressure.
No cores will be taken. Prior to running intermediate casing a gamma ray and resistivitylog willbe run.
7. Anticipated Drilling Conditions:Based on the Lansdale Gov. #13 well drilled 350 feet east of this location in May of 1968, theSalt Wash zone is depleted to 5 psi and the Entrada is 155 #. Attached as DP-2 are gas analysesfor both zones. The Entrada is a non combustible gas mixture with only 8.5% methane and6.47% helium, and 83.8% Nitrogen. The Salt Wash zone of the Morrison is similar gas with
14.8% methane and only 2.4% helium.
8. OperationsIt is anticipated that the well willspud within 60 days of approved permit, it will take a week toten days to drilL Once the well is drilled it will be ready for the testing. We willrun a five daystep rated flowtest to determine reservoir parameters. Based on the flowtesting, the decisionwill be made to run a flow line and install the hellum separation plant or plug and abandon thewelL It is estimated that the flowlinewilltake a week to ten daysto install and the plantinstallation willtake two weeks. From spud to first production of separated helium isanticipated to be 45-60 days.
Flatirons Federal #4-1: Drilling Plan Page 3 October 3,
API Well Number: 43019500290000
Our blooie line as shown will be 40 feet long and aimed into the pit, We will keep 120 bbis of
fresh water on site at all times to killthe well, which is more than twice the volume of the holeat total depth. From the Salt Wash zone to TD we will keep a smudge pot at the end of theblooie line to ignite any combustible gas that is encountered. We will be set up to spray freshwater into the blooie lineto suppress any dust that is created.
6. Testing, Coring, and Logging
As the well is drilling we willshut down at the indication of anygas entry into the wellbore tomeasure the_flowingrate, If significant gas is encountered we will shut down to measure a flowrate, get a gas sample and shut in pressure.
No cores will be taken. Prior to running intermediate casing a gamma ray and resistivitylog willbe run.
7. Anticipated Drilling Conditions:Based on the Lansdale Gov. #13 well drilled 350 feet east of this location in May of 1968, theSalt Wash zone is depleted to 5 psi and the Entrada is 155 #. Attached as DP-2 are gas analysesfor both zones. The Entrada is a non combustible gas mixture with only 8.5% methane and6.47% helium, and 83.8% Nitrogen. The Salt Wash zone of the Morrison is similar gas with
14.8% methane and only 2.4% helium.
8. OperationsIt is anticipated that the well willspud within 60 days of approved permit, it will take a week toten days to drilL Once the well is drilled it will be ready for the testing. We willrun a five daystep rated flowtest to determine reservoir parameters. Based on the flowtesting, the decisionwill be made to run a flow line and install the hellum separation plant or plug and abandon thewelL It is estimated that the flowlinewilltake a week to ten daysto install and the plantinstallation willtake two weeks. From spud to first production of separated helium isanticipated to be 45-60 days.
Flatirons Federal #4-1: Drilling Plan Page 3 October 3,
API Well Number: 43019500290000
Our blooie line as shown will be 40 feet long and aimed into the pit, We will keep 120 bbis of
fresh water on site at all times to killthe well, which is more than twice the volume of the holeat total depth. From the Salt Wash zone to TD we will keep a smudge pot at the end of theblooie line to ignite any combustible gas that is encountered. We will be set up to spray freshwater into the blooie lineto suppress any dust that is created.
6. Testing, Coring, and Logging
As the well is drilling we willshut down at the indication of anygas entry into the wellbore tomeasure the_flowingrate, If significant gas is encountered we will shut down to measure a flowrate, get a gas sample and shut in pressure.
No cores will be taken. Prior to running intermediate casing a gamma ray and resistivitylog willbe run.
7. Anticipated Drilling Conditions:Based on the Lansdale Gov. #13 well drilled 350 feet east of this location in May of 1968, theSalt Wash zone is depleted to 5 psi and the Entrada is 155 #. Attached as DP-2 are gas analysesfor both zones. The Entrada is a non combustible gas mixture with only 8.5% methane and6.47% helium, and 83.8% Nitrogen. The Salt Wash zone of the Morrison is similar gas with
14.8% methane and only 2.4% helium.
8. OperationsIt is anticipated that the well willspud within 60 days of approved permit, it will take a week toten days to drilL Once the well is drilled it will be ready for the testing. We willrun a five daystep rated flowtest to determine reservoir parameters. Based on the flowtesting, the decisionwill be made to run a flow line and install the hellum separation plant or plug and abandon thewelL It is estimated that the flowlinewilltake a week to ten daysto install and the plantinstallation willtake two weeks. From spud to first production of separated helium isanticipated to be 45-60 days.
Flatirons Federal #4-1: Drilling Plan Page 3 October 3,
RECEIVED: November 12, 2012
API Well Number: 43019500290000
CONFIDE
NTIAL
API Well Number: 43019500290000
Exhibit DP-1BOP Diagram
-Series1490 Rotating Head-6" Bloole line connection
-Pipe Rams
-• -Blind Rams
2" Killline ->
,-Manual full open 7"
API Well Number: 43019500290000
Exhibit DP-1BOP Diagram
-Series1490 Rotating Head-6" Bloole line connection
-Pipe Rams
-• -Blind Rams
2" Killline ->
,-Manual full open 7"
API Well Number: 43019500290000
Exhibit DP-1BOP Diagram
-Series1490 Rotating Head-6" Bloole line connection
-Pipe Rams
-• -Blind Rams
2" Killline ->
,-Manual full open 7"
API Well Number: 43019500290000
Exhibit DP-1BOP Diagram
-Series1490 Rotating Head-6" Bloole line connection
-Pipe Rams
-• -Blind Rams
2" Killline ->
,-Manual full open 7"
API Well Number: 43019500290000
Exhibit DP-1BOP Diagram
-Series1490 Rotating Head-6" Bloole line connection
-Pipe Rams
-• -Blind Rams
2" Killline ->
,-Manual full open 7"
API Well Number: 43019500290000
Exhibit DP-1BOP Diagram
-Series1490 Rotating Head-6" Bloole line connection
-Pipe Rams
-• -Blind Rams
2" Killline ->
,-Manual full open 7"
API Well Number: 43019500290000
Exhibit DP-1BOP Diagram
-Series1490 Rotating Head-6" Bloole line connection
-Pipe Rams
-• -Blind Rams
2" Killline ->
,-Manual full open 7"
API Well Number: 43019500290000
Exhibit DP-1BOP Diagram
-Series1490 Rotating Head-6" Bloole line connection
-Pipe Rams
-• -Blind Rams
2" Killline ->
,-Manual full open 7"
API Well Number: 43019500290000
Exhibit DP-1BOP Diagram
-Series1490 Rotating Head-6" Bloole line connection
-Pipe Rams
-• -Blind Rams
2" Killline ->
,-Manual full open 7"
API Well Number: 43019500290000
Exhibit DP-1BOP Diagram
-Series1490 Rotating Head-6" Bloole line connection
-Pipe Rams
-• -Blind Rams
2" Killline ->
,-Manual full open 7"
API Well Number: 43019500290000
Exhibit DP-1BOP Diagram
-Series1490 Rotating Head-6" Bloole line connection
-Pipe Rams
-• -Blind Rams
2" Killline ->
,-Manual full open 7"
API Well Number: 43019500290000
Exhibit DP-1BOP Diagram
-Series1490 Rotating Head-6" Bloole line connection
-Pipe Rams
-• -Blind Rams
2" Killline ->
,-Manual full open 7"
API Well Number: 43019500290000
Exhibit DP-1BOP Diagram
-Series1490 Rotating Head-6" Bloole line connection
-Pipe Rams
-• -Blind Rams
2" Killline ->
,-Manual full open 7"
API Well Number: 43019500290000
Exhibit DP-1BOP Diagram
-Series1490 Rotating Head-6" Bloole line connection
-Pipe Rams
-• -Blind Rams
2" Killline ->
,-Manual full open 7"
RECEIVED: November 12, 2012
API Well Number: 43019500290000
CONFIDE
NTIAL
API Well Number: 43019500290000
bit D 2
Company 14tisdale Déte- 1 À . No 73Weil.No.- . 'LAL - ......M. - .Locption ..
g-_1 -
PiaW HadeY M Formation MorriàowCounty... fgind ------- -.. . .....-L .. . DžÑ1k--- -
Stole Utd (Sadpli g po Ñl: } V/ellhead Separa e TrlÏnepressure,. .'.. .psig, Se$p e pre le Te e
.F
Remy -
---- -- ---
US'I.'._sgit
le or allonsComponen le or MCF
Medane AAß2EfÑyte k§P.topane W.
.
0 026laybotáne 04 0 91)N-butane 02 0 006
o.¢miýñ . .o
pentin Tracé -
oney
Tota 00 00 048
Gioss b u/co, A 60 F-& U.7 psie (dry basis . 91Specificgravity_(calucù!ated fromana ýsis) 8.Sp'ecifü· gravity (mesured) .
.
.8
01fMof yin anos & bigherractio '
API Well Number: 43019500290000
bit D 2
Company 14tisdale Déte- 1 À . No 73Weil.No.- . 'LAL - ......M. - .Locption ..
g-_1 -
PiaW HadeY M Formation MorriàowCounty... fgind ------- -.. . .....-L .. . DžÑ1k--- -
Stole Utd (Sadpli g po Ñl: } V/ellhead Separa e TrlÏnepressure,. .'.. .psig, Se$p e pre le Te e
.F
Remy -
---- -- ---
US'I.'._sgit
le or allonsComponen le or MCF
Medane AAß2EfÑyte k§P.topane W.
.
0 026laybotáne 04 0 91)N-butane 02 0 006
o.¢miýñ . .o
pentin Tracé -
oney
Tota 00 00 048
Gioss b u/co, A 60 F-& U.7 psie (dry basis . 91Specificgravity_(calucù!ated fromana ýsis) 8.Sp'ecifü· gravity (mesured) .
.
.8
01fMof yin anos & bigherractio '
API Well Number: 43019500290000
bit D 2
Company 14tisdale Déte- 1 À . No 73Weil.No.- . 'LAL - ......M. - .Locption ..
g-_1 -
PiaW HadeY M Formation MorriàowCounty... fgind ------- -.. . .....-L .. . DžÑ1k--- -
Stole Utd (Sadpli g po Ñl: } V/ellhead Separa e TrlÏnepressure,. .'.. .psig, Se$p e pre le Te e
.F
Remy -
---- -- ---
US'I.'._sgit
le or allonsComponen le or MCF
Medane AAß2EfÑyte k§P.topane W.
.
0 026laybotáne 04 0 91)N-butane 02 0 006
o.¢miýñ . .o
pentin Tracé -
oney
Tota 00 00 048
Gioss b u/co, A 60 F-& U.7 psie (dry basis . 91Specificgravity_(calucù!ated fromana ýsis) 8.Sp'ecifü· gravity (mesured) .
.
.8
01fMof yin anos & bigherractio '
API Well Number: 43019500290000
bit D 2
Company 14tisdale Déte- 1 À . No 73Weil.No.- . 'LAL - ......M. - .Locption ..
g-_1 -
PiaW HadeY M Formation MorriàowCounty... fgind ------- -.. . .....-L .. . DžÑ1k--- -
Stole Utd (Sadpli g po Ñl: } V/ellhead Separa e TrlÏnepressure,. .'.. .psig, Se$p e pre le Te e
.F
Remy -
---- -- ---
US'I.'._sgit
le or allonsComponen le or MCF
Medane AAß2EfÑyte k§P.topane W.
.
0 026laybotáne 04 0 91)N-butane 02 0 006
o.¢miýñ . .o
pentin Tracé -
oney
Tota 00 00 048
Gioss b u/co, A 60 F-& U.7 psie (dry basis . 91Specificgravity_(calucù!ated fromana ýsis) 8.Sp'ecifü· gravity (mesured) .
.
.8
01fMof yin anos & bigherractio '
API Well Number: 43019500290000
bit D 2
Company 14tisdale Déte- 1 À . No 73Weil.No.- . 'LAL - ......M. - .Locption ..
g-_1 -
PiaW HadeY M Formation MorriàowCounty... fgind ------- -.. . .....-L .. . DžÑ1k--- -
Stole Utd (Sadpli g po Ñl: } V/ellhead Separa e TrlÏnepressure,. .'.. .psig, Se$p e pre le Te e
.F
Remy -
---- -- ---
US'I.'._sgit
le or allonsComponen le or MCF
Medane AAß2EfÑyte k§P.topane W.
.
0 026laybotáne 04 0 91)N-butane 02 0 006
o.¢miýñ . .o
pentin Tracé -
oney
Tota 00 00 048
Gioss b u/co, A 60 F-& U.7 psie (dry basis . 91Specificgravity_(calucù!ated fromana ýsis) 8.Sp'ecifü· gravity (mesured) .
.
.8
01fMof yin anos & bigherractio '
API Well Number: 43019500290000
bit D 2
Company 14tisdale Déte- 1 À . No 73Weil.No.- . 'LAL - ......M. - .Locption ..
g-_1 -
PiaW HadeY M Formation MorriàowCounty... fgind ------- -.. . .....-L .. . DžÑ1k--- -
Stole Utd (Sadpli g po Ñl: } V/ellhead Separa e TrlÏnepressure,. .'.. .psig, Se$p e pre le Te e
.F
Remy -
---- -- ---
US'I.'._sgit
le or allonsComponen le or MCF
Medane AAß2EfÑyte k§P.topane W.
.
0 026laybotáne 04 0 91)N-butane 02 0 006
o.¢miýñ . .o
pentin Tracé -
oney
Tota 00 00 048
Gioss b u/co, A 60 F-& U.7 psie (dry basis . 91Specificgravity_(calucù!ated fromana ýsis) 8.Sp'ecifü· gravity (mesured) .
.
.8
01fMof yin anos & bigherractio '
API Well Number: 43019500290000
bit D 2
Company 14tisdale Déte- 1 À . No 73Weil.No.- . 'LAL - ......M. - .Locption ..
g-_1 -
PiaW HadeY M Formation MorriàowCounty... fgind ------- -.. . .....-L .. . DžÑ1k--- -
Stole Utd (Sadpli g po Ñl: } V/ellhead Separa e TrlÏnepressure,. .'.. .psig, Se$p e pre le Te e
.F
Remy -
---- -- ---
US'I.'._sgit
le or allonsComponen le or MCF
Medane AAß2EfÑyte k§P.topane W.
.
0 026laybotáne 04 0 91)N-butane 02 0 006
o.¢miýñ . .o
pentin Tracé -
oney
Tota 00 00 048
Gioss b u/co, A 60 F-& U.7 psie (dry basis . 91Specificgravity_(calucù!ated fromana ýsis) 8.Sp'ecifü· gravity (mesured) .
.
.8
01fMof yin anos & bigherractio '
API Well Number: 43019500290000
bit D 2
Company 14tisdale Déte- 1 À . No 73Weil.No.- . 'LAL - ......M. - .Locption ..
g-_1 -
PiaW HadeY M Formation MorriàowCounty... fgind ------- -.. . .....-L .. . DžÑ1k--- -
Stole Utd (Sadpli g po Ñl: } V/ellhead Separa e TrlÏnepressure,. .'.. .psig, Se$p e pre le Te e
.F
Remy -
---- -- ---
US'I.'._sgit
le or allonsComponen le or MCF
Medane AAß2EfÑyte k§P.topane W.
.
0 026laybotáne 04 0 91)N-butane 02 0 006
o.¢miýñ . .o
pentin Tracé -
oney
Tota 00 00 048
Gioss b u/co, A 60 F-& U.7 psie (dry basis . 91Specificgravity_(calucù!ated fromana ýsis) 8.Sp'ecifü· gravity (mesured) .
.
.8
01fMof yin anos & bigherractio '
API Well Number: 43019500290000
bit D 2
Company 14tisdale Déte- 1 À . No 73Weil.No.- . 'LAL - ......M. - .Locption ..
g-_1 -
PiaW HadeY M Formation MorriàowCounty... fgind ------- -.. . .....-L .. . DžÑ1k--- -
Stole Utd (Sadpli g po Ñl: } V/ellhead Separa e TrlÏnepressure,. .'.. .psig, Se$p e pre le Te e
.F
Remy -
---- -- ---
US'I.'._sgit
le or allonsComponen le or MCF
Medane AAß2EfÑyte k§P.topane W.
.
0 026laybotáne 04 0 91)N-butane 02 0 006
o.¢miýñ . .o
pentin Tracé -
oney
Tota 00 00 048
Gioss b u/co, A 60 F-& U.7 psie (dry basis . 91Specificgravity_(calucù!ated fromana ýsis) 8.Sp'ecifü· gravity (mesured) .
.
.8
01fMof yin anos & bigherractio '
API Well Number: 43019500290000
bit D 2
Company 14tisdale Déte- 1 À . No 73Weil.No.- . 'LAL - ......M. - .Locption ..
g-_1 -
PiaW HadeY M Formation MorriàowCounty... fgind ------- -.. . .....-L .. . DžÑ1k--- -
Stole Utd (Sadpli g po Ñl: } V/ellhead Separa e TrlÏnepressure,. .'.. .psig, Se$p e pre le Te e
.F
Remy -
---- -- ---
US'I.'._sgit
le or allonsComponen le or MCF
Medane AAß2EfÑyte k§P.topane W.
.
0 026laybotáne 04 0 91)N-butane 02 0 006
o.¢miýñ . .o
pentin Tracé -
oney
Tota 00 00 048
Gioss b u/co, A 60 F-& U.7 psie (dry basis . 91Specificgravity_(calucù!ated fromana ýsis) 8.Sp'ecifü· gravity (mesured) .
.
.8
01fMof yin anos & bigherractio '
API Well Number: 43019500290000
bit D 2
Company 14tisdale Déte- 1 À . No 73Weil.No.- . 'LAL - ......M. - .Locption ..
g-_1 -
PiaW HadeY M Formation MorriàowCounty... fgind ------- -.. . .....-L .. . DžÑ1k--- -
Stole Utd (Sadpli g po Ñl: } V/ellhead Separa e TrlÏnepressure,. .'.. .psig, Se$p e pre le Te e
.F
Remy -
---- -- ---
US'I.'._sgit
le or allonsComponen le or MCF
Medane AAß2EfÑyte k§P.topane W.
.
0 026laybotáne 04 0 91)N-butane 02 0 006
o.¢miýñ . .o
pentin Tracé -
oney
Tota 00 00 048
Gioss b u/co, A 60 F-& U.7 psie (dry basis . 91Specificgravity_(calucù!ated fromana ýsis) 8.Sp'ecifü· gravity (mesured) .
.
.8
01fMof yin anos & bigherractio '
API Well Number: 43019500290000
bit D 2
Company 14tisdale Déte- 1 À . No 73Weil.No.- . 'LAL - ......M. - .Locption ..
g-_1 -
PiaW HadeY M Formation MorriàowCounty... fgind ------- -.. . .....-L .. . DžÑ1k--- -
Stole Utd (Sadpli g po Ñl: } V/ellhead Separa e TrlÏnepressure,. .'.. .psig, Se$p e pre le Te e
.F
Remy -
---- -- ---
US'I.'._sgit
le or allonsComponen le or MCF
Medane AAß2EfÑyte k§P.topane W.
.
0 026laybotáne 04 0 91)N-butane 02 0 006
o.¢miýñ . .o
pentin Tracé -
oney
Tota 00 00 048
Gioss b u/co, A 60 F-& U.7 psie (dry basis . 91Specificgravity_(calucù!ated fromana ýsis) 8.Sp'ecifü· gravity (mesured) .
.
.8
01fMof yin anos & bigherractio '
API Well Number: 43019500290000
bit D 2
Company 14tisdale Déte- 1 À . No 73Weil.No.- . 'LAL - ......M. - .Locption ..
g-_1 -
PiaW HadeY M Formation MorriàowCounty... fgind ------- -.. . .....-L .. . DžÑ1k--- -
Stole Utd (Sadpli g po Ñl: } V/ellhead Separa e TrlÏnepressure,. .'.. .psig, Se$p e pre le Te e
.F
Remy -
---- -- ---
US'I.'._sgit
le or allonsComponen le or MCF
Medane AAß2EfÑyte k§P.topane W.
.
0 026laybotáne 04 0 91)N-butane 02 0 006
o.¢miýñ . .o
pentin Tracé -
oney
Tota 00 00 048
Gioss b u/co, A 60 F-& U.7 psie (dry basis . 91Specificgravity_(calucù!ated fromana ýsis) 8.Sp'ecifü· gravity (mesured) .
.
.8
01fMof yin anos & bigherractio '
API Well Number: 43019500290000
bit D 2
Company 14tisdale Déte- 1 À . No 73Weil.No.- . 'LAL - ......M. - .Locption ..
g-_1 -
PiaW HadeY M Formation MorriàowCounty... fgind ------- -.. . .....-L .. . DžÑ1k--- -
Stole Utd (Sadpli g po Ñl: } V/ellhead Separa e TrlÏnepressure,. .'.. .psig, Se$p e pre le Te e
.F
Remy -
---- -- ---
US'I.'._sgit
le or allonsComponen le or MCF
Medane AAß2EfÑyte k§P.topane W.
.
0 026laybotáne 04 0 91)N-butane 02 0 006
o.¢miýñ . .o
pentin Tracé -
oney
Tota 00 00 048
Gioss b u/co, A 60 F-& U.7 psie (dry basis . 91Specificgravity_(calucù!ated fromana ýsis) 8.Sp'ecifü· gravity (mesured) .
.
.8
01fMof yin anos & bigherractio '
RECEIVED: November 12, 2012
API Well Number: 43019500290000
CONFIDE
NTIAL
API Well Number: 43019500290000
nr 4 tuo a i e2a-1WaUNo Šn3 Mo J13
.
' S 4 198-2Harl 94ee tion , In
ruhty $90State ah S ng o nt Welhea e
psig Sam e pressure sic Te r r
19
0 02
. etã1 -- 100 00
. o b c 607 4.7.psle (dry s)Spe y (c ac lated M inalyils
owee '
hh et
API Well Number: 43019500290000
nr 4 tuo a i e2a-1WaUNo Šn3 Mo J13
.
' S 4 198-2Harl 94ee tion , In
ruhty $90State ah S ng o nt Welhea e
psig Sam e pressure sic Te r r
19
0 02
. etã1 -- 100 00
. o b c 607 4.7.psle (dry s)Spe y (c ac lated M inalyils
owee '
hh et
API Well Number: 43019500290000
nr 4 tuo a i e2a-1WaUNo Šn3 Mo J13
.
' S 4 198-2Harl 94ee tion , In
ruhty $90State ah S ng o nt Welhea e
psig Sam e pressure sic Te r r
19
0 02
. etã1 -- 100 00
. o b c 607 4.7.psle (dry s)Spe y (c ac lated M inalyils
owee '
hh et
API Well Number: 43019500290000
nr 4 tuo a i e2a-1WaUNo Šn3 Mo J13
.
' S 4 198-2Harl 94ee tion , In
ruhty $90State ah S ng o nt Welhea e
psig Sam e pressure sic Te r r
19
0 02
. etã1 -- 100 00
. o b c 607 4.7.psle (dry s)Spe y (c ac lated M inalyils
owee '
hh et
API Well Number: 43019500290000
nr 4 tuo a i e2a-1WaUNo Šn3 Mo J13
.
' S 4 198-2Harl 94ee tion , In
ruhty $90State ah S ng o nt Welhea e
psig Sam e pressure sic Te r r
19
0 02
. etã1 -- 100 00
. o b c 607 4.7.psle (dry s)Spe y (c ac lated M inalyils
owee '
hh et
API Well Number: 43019500290000
nr 4 tuo a i e2a-1WaUNo Šn3 Mo J13
.
' S 4 198-2Harl 94ee tion , In
ruhty $90State ah S ng o nt Welhea e
psig Sam e pressure sic Te r r
19
0 02
. etã1 -- 100 00
. o b c 607 4.7.psle (dry s)Spe y (c ac lated M inalyils
owee '
hh et
API Well Number: 43019500290000
nr 4 tuo a i e2a-1WaUNo Šn3 Mo J13
.
' S 4 198-2Harl 94ee tion , In
ruhty $90State ah S ng o nt Welhea e
psig Sam e pressure sic Te r r
19
0 02
. etã1 -- 100 00
. o b c 607 4.7.psle (dry s)Spe y (c ac lated M inalyils
owee '
hh et
API Well Number: 43019500290000
nr 4 tuo a i e2a-1WaUNo Šn3 Mo J13
.
' S 4 198-2Harl 94ee tion , In
ruhty $90State ah S ng o nt Welhea e
psig Sam e pressure sic Te r r
19
0 02
. etã1 -- 100 00
. o b c 607 4.7.psle (dry s)Spe y (c ac lated M inalyils
owee '
hh et
API Well Number: 43019500290000
nr 4 tuo a i e2a-1WaUNo Šn3 Mo J13
.
' S 4 198-2Harl 94ee tion , In
ruhty $90State ah S ng o nt Welhea e
psig Sam e pressure sic Te r r
19
0 02
. etã1 -- 100 00
. o b c 607 4.7.psle (dry s)Spe y (c ac lated M inalyils
owee '
hh et
API Well Number: 43019500290000
nr 4 tuo a i e2a-1WaUNo Šn3 Mo J13
.
' S 4 198-2Harl 94ee tion , In
ruhty $90State ah S ng o nt Welhea e
psig Sam e pressure sic Te r r
19
0 02
. etã1 -- 100 00
. o b c 607 4.7.psle (dry s)Spe y (c ac lated M inalyils
owee '
hh et
API Well Number: 43019500290000
nr 4 tuo a i e2a-1WaUNo Šn3 Mo J13
.
' S 4 198-2Harl 94ee tion , In
ruhty $90State ah S ng o nt Welhea e
psig Sam e pressure sic Te r r
19
0 02
. etã1 -- 100 00
. o b c 607 4.7.psle (dry s)Spe y (c ac lated M inalyils
owee '
hh et
API Well Number: 43019500290000
nr 4 tuo a i e2a-1WaUNo Šn3 Mo J13
.
' S 4 198-2Harl 94ee tion , In
ruhty $90State ah S ng o nt Welhea e
psig Sam e pressure sic Te r r
19
0 02
. etã1 -- 100 00
. o b c 607 4.7.psle (dry s)Spe y (c ac lated M inalyils
owee '
hh et
API Well Number: 43019500290000
nr 4 tuo a i e2a-1WaUNo Šn3 Mo J13
.
' S 4 198-2Harl 94ee tion , In
ruhty $90State ah S ng o nt Welhea e
psig Sam e pressure sic Te r r
19
0 02
. etã1 -- 100 00
. o b c 607 4.7.psle (dry s)Spe y (c ac lated M inalyils
owee '
hh et
API Well Number: 43019500290000
nr 4 tuo a i e2a-1WaUNo Šn3 Mo J13
.
' S 4 198-2Harl 94ee tion , In
ruhty $90State ah S ng o nt Welhea e
psig Sam e pressure sic Te r r
19
0 02
. etã1 -- 100 00
. o b c 607 4.7.psle (dry s)Spe y (c ac lated M inalyils
owee '
hh et
RECEIVED: November 12, 2012
API Well Number: 43019500290000
CONFIDE
NTIAL
API Well Number: 43019500290000
SECTlON4, T19S, R25E, SLB&M,GRANDCOUNTY, UTAHS¼ CornerSection JJT185. R25E SE Corner
SL&BM Section JJT18S, R25E
5893 50" 2650.59 SL&BM
N¼ Corner NE CornerSection 4 Section 4T19S, R2SE T195. R25E
SL&BM SL&BMI
Federal /1-4LA f 39 11'40.68J64" $LON: 109'08'57.85471" -- , èN: 6864138.66E:2]Q65J5.08
Existing Wells
EN Corner893 SO"a 265 59' Section 4-- - - _ _ _ T19S, R25ECc cm ec SL&BM
I
SE CornerSection 4
T195. R25ESL&BM
WELLLOCATIONhs ,te i _ocador Po ..cs prepare: 'er -;o: rors
3escorres, _LC :0 s"o e ocction c:ircrs Fece o
es c' :re ort ecs: corne of Section I,¯ 95
P2 E, 5_Bi coc County, sich. cosec or the O 500 1000 2000coo ior c2 re ort- Oaorte- corner, the Scr reos
come a te Ece: en ter correr of so o See a2 t ce a-: Lo,p:t-ce ore coseo or ] 23. SCALE 1"=1000'
e es :-e ^ eceu-ed et 9 from re -eferemoec
SURVEYOR'SSTATEMENT ALLA
Well Plat Plâf 11 i Flatirons Federal #1-4
1673 Highway 50 Unit C Flatirons Resources, LLCGRAND JUNCTION, CO. 81503 3DRVEYBY: pffdj Survey Date:5-17-12 Job No. 12-41
TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTlON4, T19S, R25E, SLB&M,GRANDCOUNTY, UTAHS¼ CornerSection JJT185. R25E SE Corner
SL&BM Section JJT18S, R25E
5893 50" 2650.59 SL&BM
N¼ Corner NE CornerSection 4 Section 4T19S, R2SE T195. R25E
SL&BM SL&BMI
Federal /1-4LA f 39 11'40.68J64" $LON: 109'08'57.85471" -- , èN: 6864138.66E:2]Q65J5.08
Existing Wells
EN Corner893 SO"a 265 59' Section 4-- - - _ _ _ T19S, R25ECc cm ec SL&BM
I
SE CornerSection 4
T195. R25ESL&BM
WELLLOCATIONhs ,te i _ocador Po ..cs prepare: 'er -;o: rors
3escorres, _LC :0 s"o e ocction c:ircrs Fece o
es c' :re ort ecs: corne of Section I,¯ 95
P2 E, 5_Bi coc County, sich. cosec or the O 500 1000 2000coo ior c2 re ort- Oaorte- corner, the Scr reos
come a te Ece: en ter correr of so o See a2 t ce a-: Lo,p:t-ce ore coseo or ] 23. SCALE 1"=1000'
e es :-e ^ eceu-ed et 9 from re -eferemoec
SURVEYOR'SSTATEMENT ALLA
Well Plat Plâf 11 i Flatirons Federal #1-4
1673 Highway 50 Unit C Flatirons Resources, LLCGRAND JUNCTION, CO. 81503 3DRVEYBY: pffdj Survey Date:5-17-12 Job No. 12-41
TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTlON4, T19S, R25E, SLB&M,GRANDCOUNTY, UTAHS¼ CornerSection JJT185. R25E SE Corner
SL&BM Section JJT18S, R25E
5893 50" 2650.59 SL&BM
N¼ Corner NE CornerSection 4 Section 4T19S, R2SE T195. R25E
SL&BM SL&BMI
Federal /1-4LA f 39 11'40.68J64" $LON: 109'08'57.85471" -- , èN: 6864138.66E:2]Q65J5.08
Existing Wells
EN Corner893 SO"a 265 59' Section 4-- - - _ _ _ T19S, R25ECc cm ec SL&BM
I
SE CornerSection 4
T195. R25ESL&BM
WELLLOCATIONhs ,te i _ocador Po ..cs prepare: 'er -;o: rors
3escorres, _LC :0 s"o e ocction c:ircrs Fece o
es c' :re ort ecs: corne of Section I,¯ 95
P2 E, 5_Bi coc County, sich. cosec or the O 500 1000 2000coo ior c2 re ort- Oaorte- corner, the Scr reos
come a te Ece: en ter correr of so o See a2 t ce a-: Lo,p:t-ce ore coseo or ] 23. SCALE 1"=1000'
e es :-e ^ eceu-ed et 9 from re -eferemoec
SURVEYOR'SSTATEMENT ALLA
Well Plat Plâf 11 i Flatirons Federal #1-4
1673 Highway 50 Unit C Flatirons Resources, LLCGRAND JUNCTION, CO. 81503 3DRVEYBY: pffdj Survey Date:5-17-12 Job No. 12-41
TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTlON4, T19S, R25E, SLB&M,GRANDCOUNTY, UTAHS¼ CornerSection JJT185. R25E SE Corner
SL&BM Section JJT18S, R25E
5893 50" 2650.59 SL&BM
N¼ Corner NE CornerSection 4 Section 4T19S, R2SE T195. R25E
SL&BM SL&BMI
Federal /1-4LA f 39 11'40.68J64" $LON: 109'08'57.85471" -- , èN: 6864138.66E:2]Q65J5.08
Existing Wells
EN Corner893 SO"a 265 59' Section 4-- - - _ _ _ T19S, R25ECc cm ec SL&BM
I
SE CornerSection 4
T195. R25ESL&BM
WELLLOCATIONhs ,te i _ocador Po ..cs prepare: 'er -;o: rors
3escorres, _LC :0 s"o e ocction c:ircrs Fece o
es c' :re ort ecs: corne of Section I,¯ 95
P2 E, 5_Bi coc County, sich. cosec or the O 500 1000 2000coo ior c2 re ort- Oaorte- corner, the Scr reos
come a te Ece: en ter correr of so o See a2 t ce a-: Lo,p:t-ce ore coseo or ] 23. SCALE 1"=1000'
e es :-e ^ eceu-ed et 9 from re -eferemoec
SURVEYOR'SSTATEMENT ALLA
Well Plat Plâf 11 i Flatirons Federal #1-4
1673 Highway 50 Unit C Flatirons Resources, LLCGRAND JUNCTION, CO. 81503 3DRVEYBY: pffdj Survey Date:5-17-12 Job No. 12-41
TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTlON4, T19S, R25E, SLB&M,GRANDCOUNTY, UTAHS¼ CornerSection JJT185. R25E SE Corner
SL&BM Section JJT18S, R25E
5893 50" 2650.59 SL&BM
N¼ Corner NE CornerSection 4 Section 4T19S, R2SE T195. R25E
SL&BM SL&BMI
Federal /1-4LA f 39 11'40.68J64" $LON: 109'08'57.85471" -- , èN: 6864138.66E:2]Q65J5.08
Existing Wells
EN Corner893 SO"a 265 59' Section 4-- - - _ _ _ T19S, R25ECc cm ec SL&BM
I
SE CornerSection 4
T195. R25ESL&BM
WELLLOCATIONhs ,te i _ocador Po ..cs prepare: 'er -;o: rors
3escorres, _LC :0 s"o e ocction c:ircrs Fece o
es c' :re ort ecs: corne of Section I,¯ 95
P2 E, 5_Bi coc County, sich. cosec or the O 500 1000 2000coo ior c2 re ort- Oaorte- corner, the Scr reos
come a te Ece: en ter correr of so o See a2 t ce a-: Lo,p:t-ce ore coseo or ] 23. SCALE 1"=1000'
e es :-e ^ eceu-ed et 9 from re -eferemoec
SURVEYOR'SSTATEMENT ALLA
Well Plat Plâf 11 i Flatirons Federal #1-4
1673 Highway 50 Unit C Flatirons Resources, LLCGRAND JUNCTION, CO. 81503 3DRVEYBY: pffdj Survey Date:5-17-12 Job No. 12-41
TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTlON4, T19S, R25E, SLB&M,GRANDCOUNTY, UTAHS¼ CornerSection JJT185. R25E SE Corner
SL&BM Section JJT18S, R25E
5893 50" 2650.59 SL&BM
N¼ Corner NE CornerSection 4 Section 4T19S, R2SE T195. R25E
SL&BM SL&BMI
Federal /1-4LA f 39 11'40.68J64" $LON: 109'08'57.85471" -- , èN: 6864138.66E:2]Q65J5.08
Existing Wells
EN Corner893 SO"a 265 59' Section 4-- - - _ _ _ T19S, R25ECc cm ec SL&BM
I
SE CornerSection 4
T195. R25ESL&BM
WELLLOCATIONhs ,te i _ocador Po ..cs prepare: 'er -;o: rors
3escorres, _LC :0 s"o e ocction c:ircrs Fece o
es c' :re ort ecs: corne of Section I,¯ 95
P2 E, 5_Bi coc County, sich. cosec or the O 500 1000 2000coo ior c2 re ort- Oaorte- corner, the Scr reos
come a te Ece: en ter correr of so o See a2 t ce a-: Lo,p:t-ce ore coseo or ] 23. SCALE 1"=1000'
e es :-e ^ eceu-ed et 9 from re -eferemoec
SURVEYOR'SSTATEMENT ALLA
Well Plat Plâf 11 i Flatirons Federal #1-4
1673 Highway 50 Unit C Flatirons Resources, LLCGRAND JUNCTION, CO. 81503 3DRVEYBY: pffdj Survey Date:5-17-12 Job No. 12-41
TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTlON4, T19S, R25E, SLB&M,GRANDCOUNTY, UTAHS¼ CornerSection JJT185. R25E SE Corner
SL&BM Section JJT18S, R25E
5893 50" 2650.59 SL&BM
N¼ Corner NE CornerSection 4 Section 4T19S, R2SE T195. R25E
SL&BM SL&BMI
Federal /1-4LA f 39 11'40.68J64" $LON: 109'08'57.85471" -- , èN: 6864138.66E:2]Q65J5.08
Existing Wells
EN Corner893 SO"a 265 59' Section 4-- - - _ _ _ T19S, R25ECc cm ec SL&BM
I
SE CornerSection 4
T195. R25ESL&BM
WELLLOCATIONhs ,te i _ocador Po ..cs prepare: 'er -;o: rors
3escorres, _LC :0 s"o e ocction c:ircrs Fece o
es c' :re ort ecs: corne of Section I,¯ 95
P2 E, 5_Bi coc County, sich. cosec or the O 500 1000 2000coo ior c2 re ort- Oaorte- corner, the Scr reos
come a te Ece: en ter correr of so o See a2 t ce a-: Lo,p:t-ce ore coseo or ] 23. SCALE 1"=1000'
e es :-e ^ eceu-ed et 9 from re -eferemoec
SURVEYOR'SSTATEMENT ALLA
Well Plat Plâf 11 i Flatirons Federal #1-4
1673 Highway 50 Unit C Flatirons Resources, LLCGRAND JUNCTION, CO. 81503 3DRVEYBY: pffdj Survey Date:5-17-12 Job No. 12-41
TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTlON4, T19S, R25E, SLB&M,GRANDCOUNTY, UTAHS¼ CornerSection JJT185. R25E SE Corner
SL&BM Section JJT18S, R25E
5893 50" 2650.59 SL&BM
N¼ Corner NE CornerSection 4 Section 4T19S, R2SE T195. R25E
SL&BM SL&BMI
Federal /1-4LA f 39 11'40.68J64" $LON: 109'08'57.85471" -- , èN: 6864138.66E:2]Q65J5.08
Existing Wells
EN Corner893 SO"a 265 59' Section 4-- - - _ _ _ T19S, R25ECc cm ec SL&BM
I
SE CornerSection 4
T195. R25ESL&BM
WELLLOCATIONhs ,te i _ocador Po ..cs prepare: 'er -;o: rors
3escorres, _LC :0 s"o e ocction c:ircrs Fece o
es c' :re ort ecs: corne of Section I,¯ 95
P2 E, 5_Bi coc County, sich. cosec or the O 500 1000 2000coo ior c2 re ort- Oaorte- corner, the Scr reos
come a te Ece: en ter correr of so o See a2 t ce a-: Lo,p:t-ce ore coseo or ] 23. SCALE 1"=1000'
e es :-e ^ eceu-ed et 9 from re -eferemoec
SURVEYOR'SSTATEMENT ALLA
Well Plat Plâf 11 i Flatirons Federal #1-4
1673 Highway 50 Unit C Flatirons Resources, LLCGRAND JUNCTION, CO. 81503 3DRVEYBY: pffdj Survey Date:5-17-12 Job No. 12-41
TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTlON4, T19S, R25E, SLB&M,GRANDCOUNTY, UTAHS¼ CornerSection JJT185. R25E SE Corner
SL&BM Section JJT18S, R25E
5893 50" 2650.59 SL&BM
N¼ Corner NE CornerSection 4 Section 4T19S, R2SE T195. R25E
SL&BM SL&BMI
Federal /1-4LA f 39 11'40.68J64" $LON: 109'08'57.85471" -- , èN: 6864138.66E:2]Q65J5.08
Existing Wells
EN Corner893 SO"a 265 59' Section 4-- - - _ _ _ T19S, R25ECc cm ec SL&BM
I
SE CornerSection 4
T195. R25ESL&BM
WELLLOCATIONhs ,te i _ocador Po ..cs prepare: 'er -;o: rors
3escorres, _LC :0 s"o e ocction c:ircrs Fece o
es c' :re ort ecs: corne of Section I,¯ 95
P2 E, 5_Bi coc County, sich. cosec or the O 500 1000 2000coo ior c2 re ort- Oaorte- corner, the Scr reos
come a te Ece: en ter correr of so o See a2 t ce a-: Lo,p:t-ce ore coseo or ] 23. SCALE 1"=1000'
e es :-e ^ eceu-ed et 9 from re -eferemoec
SURVEYOR'SSTATEMENT ALLA
Well Plat Plâf 11 i Flatirons Federal #1-4
1673 Highway 50 Unit C Flatirons Resources, LLCGRAND JUNCTION, CO. 81503 3DRVEYBY: pffdj Survey Date:5-17-12 Job No. 12-41
TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTlON4, T19S, R25E, SLB&M,GRANDCOUNTY, UTAHS¼ CornerSection JJT185. R25E SE Corner
SL&BM Section JJT18S, R25E
5893 50" 2650.59 SL&BM
N¼ Corner NE CornerSection 4 Section 4T19S, R2SE T195. R25E
SL&BM SL&BMI
Federal /1-4LA f 39 11'40.68J64" $LON: 109'08'57.85471" -- , èN: 6864138.66E:2]Q65J5.08
Existing Wells
EN Corner893 SO"a 265 59' Section 4-- - - _ _ _ T19S, R25ECc cm ec SL&BM
I
SE CornerSection 4
T195. R25ESL&BM
WELLLOCATIONhs ,te i _ocador Po ..cs prepare: 'er -;o: rors
3escorres, _LC :0 s"o e ocction c:ircrs Fece o
es c' :re ort ecs: corne of Section I,¯ 95
P2 E, 5_Bi coc County, sich. cosec or the O 500 1000 2000coo ior c2 re ort- Oaorte- corner, the Scr reos
come a te Ece: en ter correr of so o See a2 t ce a-: Lo,p:t-ce ore coseo or ] 23. SCALE 1"=1000'
e es :-e ^ eceu-ed et 9 from re -eferemoec
SURVEYOR'SSTATEMENT ALLA
Well Plat Plâf 11 i Flatirons Federal #1-4
1673 Highway 50 Unit C Flatirons Resources, LLCGRAND JUNCTION, CO. 81503 3DRVEYBY: pffdj Survey Date:5-17-12 Job No. 12-41
TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTlON4, T19S, R25E, SLB&M,GRANDCOUNTY, UTAHS¼ CornerSection JJT185. R25E SE Corner
SL&BM Section JJT18S, R25E
5893 50" 2650.59 SL&BM
N¼ Corner NE CornerSection 4 Section 4T19S, R2SE T195. R25E
SL&BM SL&BMI
Federal /1-4LA f 39 11'40.68J64" $LON: 109'08'57.85471" -- , èN: 6864138.66E:2]Q65J5.08
Existing Wells
EN Corner893 SO"a 265 59' Section 4-- - - _ _ _ T19S, R25ECc cm ec SL&BM
I
SE CornerSection 4
T195. R25ESL&BM
WELLLOCATIONhs ,te i _ocador Po ..cs prepare: 'er -;o: rors
3escorres, _LC :0 s"o e ocction c:ircrs Fece o
es c' :re ort ecs: corne of Section I,¯ 95
P2 E, 5_Bi coc County, sich. cosec or the O 500 1000 2000coo ior c2 re ort- Oaorte- corner, the Scr reos
come a te Ece: en ter correr of so o See a2 t ce a-: Lo,p:t-ce ore coseo or ] 23. SCALE 1"=1000'
e es :-e ^ eceu-ed et 9 from re -eferemoec
SURVEYOR'SSTATEMENT ALLA
Well Plat Plâf 11 i Flatirons Federal #1-4
1673 Highway 50 Unit C Flatirons Resources, LLCGRAND JUNCTION, CO. 81503 3DRVEYBY: pffdj Survey Date:5-17-12 Job No. 12-41
TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTlON4, T19S, R25E, SLB&M,GRANDCOUNTY, UTAHS¼ CornerSection JJT185. R25E SE Corner
SL&BM Section JJT18S, R25E
5893 50" 2650.59 SL&BM
N¼ Corner NE CornerSection 4 Section 4T19S, R2SE T195. R25E
SL&BM SL&BMI
Federal /1-4LA f 39 11'40.68J64" $LON: 109'08'57.85471" -- , èN: 6864138.66E:2]Q65J5.08
Existing Wells
EN Corner893 SO"a 265 59' Section 4-- - - _ _ _ T19S, R25ECc cm ec SL&BM
I
SE CornerSection 4
T195. R25ESL&BM
WELLLOCATIONhs ,te i _ocador Po ..cs prepare: 'er -;o: rors
3escorres, _LC :0 s"o e ocction c:ircrs Fece o
es c' :re ort ecs: corne of Section I,¯ 95
P2 E, 5_Bi coc County, sich. cosec or the O 500 1000 2000coo ior c2 re ort- Oaorte- corner, the Scr reos
come a te Ece: en ter correr of so o See a2 t ce a-: Lo,p:t-ce ore coseo or ] 23. SCALE 1"=1000'
e es :-e ^ eceu-ed et 9 from re -eferemoec
SURVEYOR'SSTATEMENT ALLA
Well Plat Plâf 11 i Flatirons Federal #1-4
1673 Highway 50 Unit C Flatirons Resources, LLCGRAND JUNCTION, CO. 81503 3DRVEYBY: pffdj Survey Date:5-17-12 Job No. 12-41
TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTlON4, T19S, R25E, SLB&M,GRANDCOUNTY, UTAHS¼ CornerSection JJT185. R25E SE Corner
SL&BM Section JJT18S, R25E
5893 50" 2650.59 SL&BM
N¼ Corner NE CornerSection 4 Section 4T19S, R2SE T195. R25E
SL&BM SL&BMI
Federal /1-4LA f 39 11'40.68J64" $LON: 109'08'57.85471" -- , èN: 6864138.66E:2]Q65J5.08
Existing Wells
EN Corner893 SO"a 265 59' Section 4-- - - _ _ _ T19S, R25ECc cm ec SL&BM
I
SE CornerSection 4
T195. R25ESL&BM
WELLLOCATIONhs ,te i _ocador Po ..cs prepare: 'er -;o: rors
3escorres, _LC :0 s"o e ocction c:ircrs Fece o
es c' :re ort ecs: corne of Section I,¯ 95
P2 E, 5_Bi coc County, sich. cosec or the O 500 1000 2000coo ior c2 re ort- Oaorte- corner, the Scr reos
come a te Ece: en ter correr of so o See a2 t ce a-: Lo,p:t-ce ore coseo or ] 23. SCALE 1"=1000'
e es :-e ^ eceu-ed et 9 from re -eferemoec
SURVEYOR'SSTATEMENT ALLA
Well Plat Plâf 11 i Flatirons Federal #1-4
1673 Highway 50 Unit C Flatirons Resources, LLCGRAND JUNCTION, CO. 81503 3DRVEYBY: pffdj Survey Date:5-17-12 Job No. 12-41
TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTlON4, T19S, R25E, SLB&M,GRANDCOUNTY, UTAHS¼ CornerSection JJT185. R25E SE Corner
SL&BM Section JJT18S, R25E
5893 50" 2650.59 SL&BM
N¼ Corner NE CornerSection 4 Section 4T19S, R2SE T195. R25E
SL&BM SL&BMI
Federal /1-4LA f 39 11'40.68J64" $LON: 109'08'57.85471" -- , èN: 6864138.66E:2]Q65J5.08
Existing Wells
EN Corner893 SO"a 265 59' Section 4-- - - _ _ _ T19S, R25ECc cm ec SL&BM
I
SE CornerSection 4
T195. R25ESL&BM
WELLLOCATIONhs ,te i _ocador Po ..cs prepare: 'er -;o: rors
3escorres, _LC :0 s"o e ocction c:ircrs Fece o
es c' :re ort ecs: corne of Section I,¯ 95
P2 E, 5_Bi coc County, sich. cosec or the O 500 1000 2000coo ior c2 re ort- Oaorte- corner, the Scr reos
come a te Ece: en ter correr of so o See a2 t ce a-: Lo,p:t-ce ore coseo or ] 23. SCALE 1"=1000'
e es :-e ^ eceu-ed et 9 from re -eferemoec
SURVEYOR'SSTATEMENT ALLA
Well Plat Plâf 11 i Flatirons Federal #1-4
1673 Highway 50 Unit C Flatirons Resources, LLCGRAND JUNCTION, CO. 81503 3DRVEYBY: pffdj Survey Date:5-17-12 Job No. 12-41
TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
RECEIVED: November 12, 2012
API Well Number: 43019500290000
CONFIDE
NTIAL
API ell Number: 43019500290000
SECTION4, T19S, R25E, SLB&M,GRANDCOUWTY,UTAH
0 1000 2000 4000
SCALE 1"=2OOO'
Quadrangles Used: 1:24,000 - Harley Dome, Utah
Topography & Access - Plat 5,_ e ,
e,-:: ; A L e- Flatirons Federal #1-4
1673 Highway 50 Unit c Flatirons Resources, LLCTELE:
(9G7Ro2D54-8NCTIONFAX(97 ) 241-0451
API ell Number: 43019500290000
SECTION4, T19S, R25E, SLB&M,GRANDCOUWTY,UTAH
0 1000 2000 4000
SCALE 1"=2OOO'
Quadrangles Used: 1:24,000 - Harley Dome, Utah
Topography & Access - Plat 5,_ e ,
e,-:: ; A L e- Flatirons Federal #1-4
1673 Highway 50 Unit c Flatirons Resources, LLCTELE:
(9G7Ro2D54-8NCTIONFAX(97 ) 241-0451
API ell Number: 43019500290000
SECTION4, T19S, R25E, SLB&M,GRANDCOUWTY,UTAH
0 1000 2000 4000
SCALE 1"=2OOO'
Quadrangles Used: 1:24,000 - Harley Dome, Utah
Topography & Access - Plat 5,_ e ,
e,-:: ; A L e- Flatirons Federal #1-4
1673 Highway 50 Unit c Flatirons Resources, LLCTELE:
(9G7Ro2D54-8NCTIONFAX(97 ) 241-0451
API ell Number: 43019500290000
SECTION4, T19S, R25E, SLB&M,GRANDCOUWTY,UTAH
0 1000 2000 4000
SCALE 1"=2OOO'
Quadrangles Used: 1:24,000 - Harley Dome, Utah
Topography & Access - Plat 5,_ e ,
e,-:: ; A L e- Flatirons Federal #1-4
1673 Highway 50 Unit c Flatirons Resources, LLCTELE:
(9G7Ro2D54-8NCTIONFAX(97 ) 241-0451
API ell Number: 43019500290000
SECTION4, T19S, R25E, SLB&M,GRANDCOUWTY,UTAH
0 1000 2000 4000
SCALE 1"=2OOO'
Quadrangles Used: 1:24,000 - Harley Dome, Utah
Topography & Access - Plat 5,_ e ,
e,-:: ; A L e- Flatirons Federal #1-4
1673 Highway 50 Unit c Flatirons Resources, LLCTELE:
(9G7Ro2D54-8NCTIONFAX(97 ) 241-0451
API ell Number: 43019500290000
SECTION4, T19S, R25E, SLB&M,GRANDCOUWTY,UTAH
0 1000 2000 4000
SCALE 1"=2OOO'
Quadrangles Used: 1:24,000 - Harley Dome, Utah
Topography & Access - Plat 5,_ e ,
e,-:: ; A L e- Flatirons Federal #1-4
1673 Highway 50 Unit c Flatirons Resources, LLCTELE:
(9G7Ro2D54-8NCTIONFAX(97 ) 241-0451
API ell Number: 43019500290000
SECTION4, T19S, R25E, SLB&M,GRANDCOUWTY,UTAH
0 1000 2000 4000
SCALE 1"=2OOO'
Quadrangles Used: 1:24,000 - Harley Dome, Utah
Topography & Access - Plat 5,_ e ,
e,-:: ; A L e- Flatirons Federal #1-4
1673 Highway 50 Unit c Flatirons Resources, LLCTELE:
(9G7Ro2D54-8NCTIONFAX(97 ) 241-0451
API ell Number: 43019500290000
SECTION4, T19S, R25E, SLB&M,GRANDCOUWTY,UTAH
0 1000 2000 4000
SCALE 1"=2OOO'
Quadrangles Used: 1:24,000 - Harley Dome, Utah
Topography & Access - Plat 5,_ e ,
e,-:: ; A L e- Flatirons Federal #1-4
1673 Highway 50 Unit c Flatirons Resources, LLCTELE:
(9G7Ro2D54-8NCTIONFAX(97 ) 241-0451
API ell Number: 43019500290000
SECTION4, T19S, R25E, SLB&M,GRANDCOUWTY,UTAH
0 1000 2000 4000
SCALE 1"=2OOO'
Quadrangles Used: 1:24,000 - Harley Dome, Utah
Topography & Access - Plat 5,_ e ,
e,-:: ; A L e- Flatirons Federal #1-4
1673 Highway 50 Unit c Flatirons Resources, LLCTELE:
(9G7Ro2D54-8NCTIONFAX(97 ) 241-0451
API ell Number: 43019500290000
SECTION4, T19S, R25E, SLB&M,GRANDCOUWTY,UTAH
0 1000 2000 4000
SCALE 1"=2OOO'
Quadrangles Used: 1:24,000 - Harley Dome, Utah
Topography & Access - Plat 5,_ e ,
e,-:: ; A L e- Flatirons Federal #1-4
1673 Highway 50 Unit c Flatirons Resources, LLCTELE:
(9G7Ro2D54-8NCTIONFAX(97 ) 241-0451
API ell Number: 43019500290000
SECTION4, T19S, R25E, SLB&M,GRANDCOUWTY,UTAH
0 1000 2000 4000
SCALE 1"=2OOO'
Quadrangles Used: 1:24,000 - Harley Dome, Utah
Topography & Access - Plat 5,_ e ,
e,-:: ; A L e- Flatirons Federal #1-4
1673 Highway 50 Unit c Flatirons Resources, LLCTELE:
(9G7Ro2D54-8NCTIONFAX(97 ) 241-0451
API ell Number: 43019500290000
SECTION4, T19S, R25E, SLB&M,GRANDCOUWTY,UTAH
0 1000 2000 4000
SCALE 1"=2OOO'
Quadrangles Used: 1:24,000 - Harley Dome, Utah
Topography & Access - Plat 5,_ e ,
e,-:: ; A L e- Flatirons Federal #1-4
1673 Highway 50 Unit c Flatirons Resources, LLCTELE:
(9G7Ro2D54-8NCTIONFAX(97 ) 241-0451
API ell Number: 43019500290000
SECTION4, T19S, R25E, SLB&M,GRANDCOUWTY,UTAH
0 1000 2000 4000
SCALE 1"=2OOO'
Quadrangles Used: 1:24,000 - Harley Dome, Utah
Topography & Access - Plat 5,_ e ,
e,-:: ; A L e- Flatirons Federal #1-4
1673 Highway 50 Unit c Flatirons Resources, LLCTELE:
(9G7Ro2D54-8NCTIONFAX(97 ) 241-0451
API ell Number: 43019500290000
SECTION4, T19S, R25E, SLB&M,GRANDCOUWTY,UTAH
0 1000 2000 4000
SCALE 1"=2OOO'
Quadrangles Used: 1:24,000 - Harley Dome, Utah
Topography & Access - Plat 5,_ e ,
e,-:: ; A L e- Flatirons Federal #1-4
1673 Highway 50 Unit c Flatirons Resources, LLCTELE:
(9G7Ro2D54-8NCTIONFAX(97 ) 241-0451
RECEIVED: November 12, 2012
API Well Number: 43019500290000
CONFIDE
NTIAL
API Well Number: 43019500290000
STATE OF UTAH FORM 5DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OlL, GAS AND MINING
DESIGNATION OF AGENT OR OPERATOR
The undersigned is, on record, the holder of oil and gas lease
LEASE NAME: Flatirons Federal #1-4
LEASE NUMBER: UTU 87659
and hereby designates
NAME: Jeffery E. Jones
ADDRESS: 303 E. 17th Ave #940
city Denver state CO zip 80203
as his (check one) agent Ol operator Œ with full authority to act in his behalf in complying with the terms of the lease andregulations applicable thereto and on whom the Division Director or Authorized Agent may serve written or oral instructions insecuring compliance with the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Miningof the State of Utah with respect to:
(Describe acreage to which this designation is applicable. Identify each oil and gas well by API number and name. Attach additional pages asneeded.)
Federal lands 802.31 acres 80 acres dedicated to this wellfor the spacing unit
It is understood that this designation of agentloperator does not relieve the lessee of responsibility for compliance with the termsof the lease and the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Mining of theState of Utah. It is also understood that this designation of agent or operator does not constitute an assignment of any interest inthe lease.
Incase of default on the part of the designated agent/operator, the lessee willmake fulland prompt compliance with all rules, leaseterms or orders of the Board of Oil, Gas and Mining of the State of Utah or its authorized representative.
The lessee agrees to promptly notify the Division Director or Authorized Agent of any change in thisdesignation.
Effective Date of Designation:
Jeffery E. Jones Flatirons Resources LLCBY: ag
ature) y ,
OF: om ny)
303 E. 17th Ave Suite 940
(Title) gi ' Direc or city Denver
(Phone) 003)2 -Åstate CO zip 80203
API Well Number: 43019500290000
STATE OF UTAH FORM 5DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OlL, GAS AND MINING
DESIGNATION OF AGENT OR OPERATOR
The undersigned is, on record, the holder of oil and gas lease
LEASE NAME: Flatirons Federal #1-4
LEASE NUMBER: UTU 87659
and hereby designates
NAME: Jeffery E. Jones
ADDRESS: 303 E. 17th Ave #940
city Denver state CO zip 80203
as his (check one) agent Ol operator Œ with full authority to act in his behalf in complying with the terms of the lease andregulations applicable thereto and on whom the Division Director or Authorized Agent may serve written or oral instructions insecuring compliance with the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Miningof the State of Utah with respect to:
(Describe acreage to which this designation is applicable. Identify each oil and gas well by API number and name. Attach additional pages asneeded.)
Federal lands 802.31 acres 80 acres dedicated to this wellfor the spacing unit
It is understood that this designation of agentloperator does not relieve the lessee of responsibility for compliance with the termsof the lease and the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Mining of theState of Utah. It is also understood that this designation of agent or operator does not constitute an assignment of any interest inthe lease.
Incase of default on the part of the designated agent/operator, the lessee willmake fulland prompt compliance with all rules, leaseterms or orders of the Board of Oil, Gas and Mining of the State of Utah or its authorized representative.
The lessee agrees to promptly notify the Division Director or Authorized Agent of any change in thisdesignation.
Effective Date of Designation:
Jeffery E. Jones Flatirons Resources LLCBY: ag
ature) y ,
OF: om ny)
303 E. 17th Ave Suite 940
(Title) gi ' Direc or city Denver
(Phone) 003)2 -Åstate CO zip 80203
API Well Number: 43019500290000
STATE OF UTAH FORM 5DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OlL, GAS AND MINING
DESIGNATION OF AGENT OR OPERATOR
The undersigned is, on record, the holder of oil and gas lease
LEASE NAME: Flatirons Federal #1-4
LEASE NUMBER: UTU 87659
and hereby designates
NAME: Jeffery E. Jones
ADDRESS: 303 E. 17th Ave #940
city Denver state CO zip 80203
as his (check one) agent Ol operator Œ with full authority to act in his behalf in complying with the terms of the lease andregulations applicable thereto and on whom the Division Director or Authorized Agent may serve written or oral instructions insecuring compliance with the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Miningof the State of Utah with respect to:
(Describe acreage to which this designation is applicable. Identify each oil and gas well by API number and name. Attach additional pages asneeded.)
Federal lands 802.31 acres 80 acres dedicated to this wellfor the spacing unit
It is understood that this designation of agentloperator does not relieve the lessee of responsibility for compliance with the termsof the lease and the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Mining of theState of Utah. It is also understood that this designation of agent or operator does not constitute an assignment of any interest inthe lease.
Incase of default on the part of the designated agent/operator, the lessee willmake fulland prompt compliance with all rules, leaseterms or orders of the Board of Oil, Gas and Mining of the State of Utah or its authorized representative.
The lessee agrees to promptly notify the Division Director or Authorized Agent of any change in thisdesignation.
Effective Date of Designation:
Jeffery E. Jones Flatirons Resources LLCBY: ag
ature) y ,
OF: om ny)
303 E. 17th Ave Suite 940
(Title) gi ' Direc or city Denver
(Phone) 003)2 -Åstate CO zip 80203
API Well Number: 43019500290000
STATE OF UTAH FORM 5DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OlL, GAS AND MINING
DESIGNATION OF AGENT OR OPERATOR
The undersigned is, on record, the holder of oil and gas lease
LEASE NAME: Flatirons Federal #1-4
LEASE NUMBER: UTU 87659
and hereby designates
NAME: Jeffery E. Jones
ADDRESS: 303 E. 17th Ave #940
city Denver state CO zip 80203
as his (check one) agent Ol operator Œ with full authority to act in his behalf in complying with the terms of the lease andregulations applicable thereto and on whom the Division Director or Authorized Agent may serve written or oral instructions insecuring compliance with the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Miningof the State of Utah with respect to:
(Describe acreage to which this designation is applicable. Identify each oil and gas well by API number and name. Attach additional pages asneeded.)
Federal lands 802.31 acres 80 acres dedicated to this wellfor the spacing unit
It is understood that this designation of agentloperator does not relieve the lessee of responsibility for compliance with the termsof the lease and the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Mining of theState of Utah. It is also understood that this designation of agent or operator does not constitute an assignment of any interest inthe lease.
Incase of default on the part of the designated agent/operator, the lessee willmake fulland prompt compliance with all rules, leaseterms or orders of the Board of Oil, Gas and Mining of the State of Utah or its authorized representative.
The lessee agrees to promptly notify the Division Director or Authorized Agent of any change in thisdesignation.
Effective Date of Designation:
Jeffery E. Jones Flatirons Resources LLCBY: ag
ature) y ,
OF: om ny)
303 E. 17th Ave Suite 940
(Title) gi ' Direc or city Denver
(Phone) 003)2 -Åstate CO zip 80203
API Well Number: 43019500290000
STATE OF UTAH FORM 5DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OlL, GAS AND MINING
DESIGNATION OF AGENT OR OPERATOR
The undersigned is, on record, the holder of oil and gas lease
LEASE NAME: Flatirons Federal #1-4
LEASE NUMBER: UTU 87659
and hereby designates
NAME: Jeffery E. Jones
ADDRESS: 303 E. 17th Ave #940
city Denver state CO zip 80203
as his (check one) agent Ol operator Œ with full authority to act in his behalf in complying with the terms of the lease andregulations applicable thereto and on whom the Division Director or Authorized Agent may serve written or oral instructions insecuring compliance with the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Miningof the State of Utah with respect to:
(Describe acreage to which this designation is applicable. Identify each oil and gas well by API number and name. Attach additional pages asneeded.)
Federal lands 802.31 acres 80 acres dedicated to this wellfor the spacing unit
It is understood that this designation of agentloperator does not relieve the lessee of responsibility for compliance with the termsof the lease and the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Mining of theState of Utah. It is also understood that this designation of agent or operator does not constitute an assignment of any interest inthe lease.
Incase of default on the part of the designated agent/operator, the lessee willmake fulland prompt compliance with all rules, leaseterms or orders of the Board of Oil, Gas and Mining of the State of Utah or its authorized representative.
The lessee agrees to promptly notify the Division Director or Authorized Agent of any change in thisdesignation.
Effective Date of Designation:
Jeffery E. Jones Flatirons Resources LLCBY: ag
ature) y ,
OF: om ny)
303 E. 17th Ave Suite 940
(Title) gi ' Direc or city Denver
(Phone) 003)2 -Åstate CO zip 80203
API Well Number: 43019500290000
STATE OF UTAH FORM 5DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OlL, GAS AND MINING
DESIGNATION OF AGENT OR OPERATOR
The undersigned is, on record, the holder of oil and gas lease
LEASE NAME: Flatirons Federal #1-4
LEASE NUMBER: UTU 87659
and hereby designates
NAME: Jeffery E. Jones
ADDRESS: 303 E. 17th Ave #940
city Denver state CO zip 80203
as his (check one) agent Ol operator Œ with full authority to act in his behalf in complying with the terms of the lease andregulations applicable thereto and on whom the Division Director or Authorized Agent may serve written or oral instructions insecuring compliance with the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Miningof the State of Utah with respect to:
(Describe acreage to which this designation is applicable. Identify each oil and gas well by API number and name. Attach additional pages asneeded.)
Federal lands 802.31 acres 80 acres dedicated to this wellfor the spacing unit
It is understood that this designation of agentloperator does not relieve the lessee of responsibility for compliance with the termsof the lease and the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Mining of theState of Utah. It is also understood that this designation of agent or operator does not constitute an assignment of any interest inthe lease.
Incase of default on the part of the designated agent/operator, the lessee willmake fulland prompt compliance with all rules, leaseterms or orders of the Board of Oil, Gas and Mining of the State of Utah or its authorized representative.
The lessee agrees to promptly notify the Division Director or Authorized Agent of any change in thisdesignation.
Effective Date of Designation:
Jeffery E. Jones Flatirons Resources LLCBY: ag
ature) y ,
OF: om ny)
303 E. 17th Ave Suite 940
(Title) gi ' Direc or city Denver
(Phone) 003)2 -Åstate CO zip 80203
API Well Number: 43019500290000
STATE OF UTAH FORM 5DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OlL, GAS AND MINING
DESIGNATION OF AGENT OR OPERATOR
The undersigned is, on record, the holder of oil and gas lease
LEASE NAME: Flatirons Federal #1-4
LEASE NUMBER: UTU 87659
and hereby designates
NAME: Jeffery E. Jones
ADDRESS: 303 E. 17th Ave #940
city Denver state CO zip 80203
as his (check one) agent Ol operator Œ with full authority to act in his behalf in complying with the terms of the lease andregulations applicable thereto and on whom the Division Director or Authorized Agent may serve written or oral instructions insecuring compliance with the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Miningof the State of Utah with respect to:
(Describe acreage to which this designation is applicable. Identify each oil and gas well by API number and name. Attach additional pages asneeded.)
Federal lands 802.31 acres 80 acres dedicated to this wellfor the spacing unit
It is understood that this designation of agentloperator does not relieve the lessee of responsibility for compliance with the termsof the lease and the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Mining of theState of Utah. It is also understood that this designation of agent or operator does not constitute an assignment of any interest inthe lease.
Incase of default on the part of the designated agent/operator, the lessee willmake fulland prompt compliance with all rules, leaseterms or orders of the Board of Oil, Gas and Mining of the State of Utah or its authorized representative.
The lessee agrees to promptly notify the Division Director or Authorized Agent of any change in thisdesignation.
Effective Date of Designation:
Jeffery E. Jones Flatirons Resources LLCBY: ag
ature) y ,
OF: om ny)
303 E. 17th Ave Suite 940
(Title) gi ' Direc or city Denver
(Phone) 003)2 -Åstate CO zip 80203
API Well Number: 43019500290000
STATE OF UTAH FORM 5DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OlL, GAS AND MINING
DESIGNATION OF AGENT OR OPERATOR
The undersigned is, on record, the holder of oil and gas lease
LEASE NAME: Flatirons Federal #1-4
LEASE NUMBER: UTU 87659
and hereby designates
NAME: Jeffery E. Jones
ADDRESS: 303 E. 17th Ave #940
city Denver state CO zip 80203
as his (check one) agent Ol operator Œ with full authority to act in his behalf in complying with the terms of the lease andregulations applicable thereto and on whom the Division Director or Authorized Agent may serve written or oral instructions insecuring compliance with the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Miningof the State of Utah with respect to:
(Describe acreage to which this designation is applicable. Identify each oil and gas well by API number and name. Attach additional pages asneeded.)
Federal lands 802.31 acres 80 acres dedicated to this wellfor the spacing unit
It is understood that this designation of agentloperator does not relieve the lessee of responsibility for compliance with the termsof the lease and the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Mining of theState of Utah. It is also understood that this designation of agent or operator does not constitute an assignment of any interest inthe lease.
Incase of default on the part of the designated agent/operator, the lessee willmake fulland prompt compliance with all rules, leaseterms or orders of the Board of Oil, Gas and Mining of the State of Utah or its authorized representative.
The lessee agrees to promptly notify the Division Director or Authorized Agent of any change in thisdesignation.
Effective Date of Designation:
Jeffery E. Jones Flatirons Resources LLCBY: ag
ature) y ,
OF: om ny)
303 E. 17th Ave Suite 940
(Title) gi ' Direc or city Denver
(Phone) 003)2 -Åstate CO zip 80203
API Well Number: 43019500290000
STATE OF UTAH FORM 5DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OlL, GAS AND MINING
DESIGNATION OF AGENT OR OPERATOR
The undersigned is, on record, the holder of oil and gas lease
LEASE NAME: Flatirons Federal #1-4
LEASE NUMBER: UTU 87659
and hereby designates
NAME: Jeffery E. Jones
ADDRESS: 303 E. 17th Ave #940
city Denver state CO zip 80203
as his (check one) agent Ol operator Œ with full authority to act in his behalf in complying with the terms of the lease andregulations applicable thereto and on whom the Division Director or Authorized Agent may serve written or oral instructions insecuring compliance with the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Miningof the State of Utah with respect to:
(Describe acreage to which this designation is applicable. Identify each oil and gas well by API number and name. Attach additional pages asneeded.)
Federal lands 802.31 acres 80 acres dedicated to this wellfor the spacing unit
It is understood that this designation of agentloperator does not relieve the lessee of responsibility for compliance with the termsof the lease and the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Mining of theState of Utah. It is also understood that this designation of agent or operator does not constitute an assignment of any interest inthe lease.
Incase of default on the part of the designated agent/operator, the lessee willmake fulland prompt compliance with all rules, leaseterms or orders of the Board of Oil, Gas and Mining of the State of Utah or its authorized representative.
The lessee agrees to promptly notify the Division Director or Authorized Agent of any change in thisdesignation.
Effective Date of Designation:
Jeffery E. Jones Flatirons Resources LLCBY: ag
ature) y ,
OF: om ny)
303 E. 17th Ave Suite 940
(Title) gi ' Direc or city Denver
(Phone) 003)2 -Åstate CO zip 80203
API Well Number: 43019500290000
STATE OF UTAH FORM 5DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OlL, GAS AND MINING
DESIGNATION OF AGENT OR OPERATOR
The undersigned is, on record, the holder of oil and gas lease
LEASE NAME: Flatirons Federal #1-4
LEASE NUMBER: UTU 87659
and hereby designates
NAME: Jeffery E. Jones
ADDRESS: 303 E. 17th Ave #940
city Denver state CO zip 80203
as his (check one) agent Ol operator Œ with full authority to act in his behalf in complying with the terms of the lease andregulations applicable thereto and on whom the Division Director or Authorized Agent may serve written or oral instructions insecuring compliance with the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Miningof the State of Utah with respect to:
(Describe acreage to which this designation is applicable. Identify each oil and gas well by API number and name. Attach additional pages asneeded.)
Federal lands 802.31 acres 80 acres dedicated to this wellfor the spacing unit
It is understood that this designation of agentloperator does not relieve the lessee of responsibility for compliance with the termsof the lease and the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Mining of theState of Utah. It is also understood that this designation of agent or operator does not constitute an assignment of any interest inthe lease.
Incase of default on the part of the designated agent/operator, the lessee willmake fulland prompt compliance with all rules, leaseterms or orders of the Board of Oil, Gas and Mining of the State of Utah or its authorized representative.
The lessee agrees to promptly notify the Division Director or Authorized Agent of any change in thisdesignation.
Effective Date of Designation:
Jeffery E. Jones Flatirons Resources LLCBY: ag
ature) y ,
OF: om ny)
303 E. 17th Ave Suite 940
(Title) gi ' Direc or city Denver
(Phone) 003)2 -Åstate CO zip 80203
API Well Number: 43019500290000
STATE OF UTAH FORM 5DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OlL, GAS AND MINING
DESIGNATION OF AGENT OR OPERATOR
The undersigned is, on record, the holder of oil and gas lease
LEASE NAME: Flatirons Federal #1-4
LEASE NUMBER: UTU 87659
and hereby designates
NAME: Jeffery E. Jones
ADDRESS: 303 E. 17th Ave #940
city Denver state CO zip 80203
as his (check one) agent Ol operator Œ with full authority to act in his behalf in complying with the terms of the lease andregulations applicable thereto and on whom the Division Director or Authorized Agent may serve written or oral instructions insecuring compliance with the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Miningof the State of Utah with respect to:
(Describe acreage to which this designation is applicable. Identify each oil and gas well by API number and name. Attach additional pages asneeded.)
Federal lands 802.31 acres 80 acres dedicated to this wellfor the spacing unit
It is understood that this designation of agentloperator does not relieve the lessee of responsibility for compliance with the termsof the lease and the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Mining of theState of Utah. It is also understood that this designation of agent or operator does not constitute an assignment of any interest inthe lease.
Incase of default on the part of the designated agent/operator, the lessee willmake fulland prompt compliance with all rules, leaseterms or orders of the Board of Oil, Gas and Mining of the State of Utah or its authorized representative.
The lessee agrees to promptly notify the Division Director or Authorized Agent of any change in thisdesignation.
Effective Date of Designation:
Jeffery E. Jones Flatirons Resources LLCBY: ag
ature) y ,
OF: om ny)
303 E. 17th Ave Suite 940
(Title) gi ' Direc or city Denver
(Phone) 003)2 -Åstate CO zip 80203
API Well Number: 43019500290000
STATE OF UTAH FORM 5DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OlL, GAS AND MINING
DESIGNATION OF AGENT OR OPERATOR
The undersigned is, on record, the holder of oil and gas lease
LEASE NAME: Flatirons Federal #1-4
LEASE NUMBER: UTU 87659
and hereby designates
NAME: Jeffery E. Jones
ADDRESS: 303 E. 17th Ave #940
city Denver state CO zip 80203
as his (check one) agent Ol operator Œ with full authority to act in his behalf in complying with the terms of the lease andregulations applicable thereto and on whom the Division Director or Authorized Agent may serve written or oral instructions insecuring compliance with the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Miningof the State of Utah with respect to:
(Describe acreage to which this designation is applicable. Identify each oil and gas well by API number and name. Attach additional pages asneeded.)
Federal lands 802.31 acres 80 acres dedicated to this wellfor the spacing unit
It is understood that this designation of agentloperator does not relieve the lessee of responsibility for compliance with the termsof the lease and the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Mining of theState of Utah. It is also understood that this designation of agent or operator does not constitute an assignment of any interest inthe lease.
Incase of default on the part of the designated agent/operator, the lessee willmake fulland prompt compliance with all rules, leaseterms or orders of the Board of Oil, Gas and Mining of the State of Utah or its authorized representative.
The lessee agrees to promptly notify the Division Director or Authorized Agent of any change in thisdesignation.
Effective Date of Designation:
Jeffery E. Jones Flatirons Resources LLCBY: ag
ature) y ,
OF: om ny)
303 E. 17th Ave Suite 940
(Title) gi ' Direc or city Denver
(Phone) 003)2 -Åstate CO zip 80203
API Well Number: 43019500290000
STATE OF UTAH FORM 5DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OlL, GAS AND MINING
DESIGNATION OF AGENT OR OPERATOR
The undersigned is, on record, the holder of oil and gas lease
LEASE NAME: Flatirons Federal #1-4
LEASE NUMBER: UTU 87659
and hereby designates
NAME: Jeffery E. Jones
ADDRESS: 303 E. 17th Ave #940
city Denver state CO zip 80203
as his (check one) agent Ol operator Œ with full authority to act in his behalf in complying with the terms of the lease andregulations applicable thereto and on whom the Division Director or Authorized Agent may serve written or oral instructions insecuring compliance with the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Miningof the State of Utah with respect to:
(Describe acreage to which this designation is applicable. Identify each oil and gas well by API number and name. Attach additional pages asneeded.)
Federal lands 802.31 acres 80 acres dedicated to this wellfor the spacing unit
It is understood that this designation of agentloperator does not relieve the lessee of responsibility for compliance with the termsof the lease and the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Mining of theState of Utah. It is also understood that this designation of agent or operator does not constitute an assignment of any interest inthe lease.
Incase of default on the part of the designated agent/operator, the lessee willmake fulland prompt compliance with all rules, leaseterms or orders of the Board of Oil, Gas and Mining of the State of Utah or its authorized representative.
The lessee agrees to promptly notify the Division Director or Authorized Agent of any change in thisdesignation.
Effective Date of Designation:
Jeffery E. Jones Flatirons Resources LLCBY: ag
ature) y ,
OF: om ny)
303 E. 17th Ave Suite 940
(Title) gi ' Direc or city Denver
(Phone) 003)2 -Åstate CO zip 80203
API Well Number: 43019500290000
STATE OF UTAH FORM 5DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OlL, GAS AND MINING
DESIGNATION OF AGENT OR OPERATOR
The undersigned is, on record, the holder of oil and gas lease
LEASE NAME: Flatirons Federal #1-4
LEASE NUMBER: UTU 87659
and hereby designates
NAME: Jeffery E. Jones
ADDRESS: 303 E. 17th Ave #940
city Denver state CO zip 80203
as his (check one) agent Ol operator Œ with full authority to act in his behalf in complying with the terms of the lease andregulations applicable thereto and on whom the Division Director or Authorized Agent may serve written or oral instructions insecuring compliance with the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Miningof the State of Utah with respect to:
(Describe acreage to which this designation is applicable. Identify each oil and gas well by API number and name. Attach additional pages asneeded.)
Federal lands 802.31 acres 80 acres dedicated to this wellfor the spacing unit
It is understood that this designation of agentloperator does not relieve the lessee of responsibility for compliance with the termsof the lease and the Oil and Gas Conservation General Rules and Procedural Rules of the Board of Oil, Gas and Mining of theState of Utah. It is also understood that this designation of agent or operator does not constitute an assignment of any interest inthe lease.
Incase of default on the part of the designated agent/operator, the lessee willmake fulland prompt compliance with all rules, leaseterms or orders of the Board of Oil, Gas and Mining of the State of Utah or its authorized representative.
The lessee agrees to promptly notify the Division Director or Authorized Agent of any change in thisdesignation.
Effective Date of Designation:
Jeffery E. Jones Flatirons Resources LLCBY: ag
ature) y ,
OF: om ny)
303 E. 17th Ave Suite 940
(Title) gi ' Direc or city Denver
(Phone) 003)2 -Åstate CO zip 80203
RECEIVED: November 12, 2012
API Well Number: 43019500290000
CONFIDE
NTIAL
API Well Number: 43019500290000
SECTION 4, T19S, R25E, SLB&M, GRANDCOUNTY,UTAH
Federal #1-4LAT:39°11'40.68364"LON:109°08'57.85471"N: 6884138.66E: 2306535.08
0 30 60 120
Scale 1"=60
Pad &cRig Layout - Plot 3Flatirons Federal #1-4
1673 Highway 50 Unit c Flat¡rons Resources, LLCGRAND JUNCTlON, CO. 81503 BURVEY BY: jeffdj Survey Date;5-17-12 Job No. 12-41TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTION 4, T19S, R25E, SLB&M, GRANDCOUNTY,UTAH
Federal #1-4LAT:39°11'40.68364"LON:109°08'57.85471"N: 6884138.66E: 2306535.08
0 30 60 120
Scale 1"=60
Pad &cRig Layout - Plot 3Flatirons Federal #1-4
1673 Highway 50 Unit c Flat¡rons Resources, LLCGRAND JUNCTlON, CO. 81503 BURVEY BY: jeffdj Survey Date;5-17-12 Job No. 12-41TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTION 4, T19S, R25E, SLB&M, GRANDCOUNTY,UTAH
Federal #1-4LAT:39°11'40.68364"LON:109°08'57.85471"N: 6884138.66E: 2306535.08
0 30 60 120
Scale 1"=60
Pad &cRig Layout - Plot 3Flatirons Federal #1-4
1673 Highway 50 Unit c Flat¡rons Resources, LLCGRAND JUNCTlON, CO. 81503 BURVEY BY: jeffdj Survey Date;5-17-12 Job No. 12-41TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTION 4, T19S, R25E, SLB&M, GRANDCOUNTY,UTAH
Federal #1-4LAT:39°11'40.68364"LON:109°08'57.85471"N: 6884138.66E: 2306535.08
0 30 60 120
Scale 1"=60
Pad &cRig Layout - Plot 3Flatirons Federal #1-4
1673 Highway 50 Unit c Flat¡rons Resources, LLCGRAND JUNCTlON, CO. 81503 BURVEY BY: jeffdj Survey Date;5-17-12 Job No. 12-41TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTION 4, T19S, R25E, SLB&M, GRANDCOUNTY,UTAH
Federal #1-4LAT:39°11'40.68364"LON:109°08'57.85471"N: 6884138.66E: 2306535.08
0 30 60 120
Scale 1"=60
Pad &cRig Layout - Plot 3Flatirons Federal #1-4
1673 Highway 50 Unit c Flat¡rons Resources, LLCGRAND JUNCTlON, CO. 81503 BURVEY BY: jeffdj Survey Date;5-17-12 Job No. 12-41TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTION 4, T19S, R25E, SLB&M, GRANDCOUNTY,UTAH
Federal #1-4LAT:39°11'40.68364"LON:109°08'57.85471"N: 6884138.66E: 2306535.08
0 30 60 120
Scale 1"=60
Pad &cRig Layout - Plot 3Flatirons Federal #1-4
1673 Highway 50 Unit c Flat¡rons Resources, LLCGRAND JUNCTlON, CO. 81503 BURVEY BY: jeffdj Survey Date;5-17-12 Job No. 12-41TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTION 4, T19S, R25E, SLB&M, GRANDCOUNTY,UTAH
Federal #1-4LAT:39°11'40.68364"LON:109°08'57.85471"N: 6884138.66E: 2306535.08
0 30 60 120
Scale 1"=60
Pad &cRig Layout - Plot 3Flatirons Federal #1-4
1673 Highway 50 Unit c Flat¡rons Resources, LLCGRAND JUNCTlON, CO. 81503 BURVEY BY: jeffdj Survey Date;5-17-12 Job No. 12-41TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTION 4, T19S, R25E, SLB&M, GRANDCOUNTY,UTAH
Federal #1-4LAT:39°11'40.68364"LON:109°08'57.85471"N: 6884138.66E: 2306535.08
0 30 60 120
Scale 1"=60
Pad &cRig Layout - Plot 3Flatirons Federal #1-4
1673 Highway 50 Unit c Flat¡rons Resources, LLCGRAND JUNCTlON, CO. 81503 BURVEY BY: jeffdj Survey Date;5-17-12 Job No. 12-41TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTION 4, T19S, R25E, SLB&M, GRANDCOUNTY,UTAH
Federal #1-4LAT:39°11'40.68364"LON:109°08'57.85471"N: 6884138.66E: 2306535.08
0 30 60 120
Scale 1"=60
Pad &cRig Layout - Plot 3Flatirons Federal #1-4
1673 Highway 50 Unit c Flat¡rons Resources, LLCGRAND JUNCTlON, CO. 81503 BURVEY BY: jeffdj Survey Date;5-17-12 Job No. 12-41TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTION 4, T19S, R25E, SLB&M, GRANDCOUNTY,UTAH
Federal #1-4LAT:39°11'40.68364"LON:109°08'57.85471"N: 6884138.66E: 2306535.08
0 30 60 120
Scale 1"=60
Pad &cRig Layout - Plot 3Flatirons Federal #1-4
1673 Highway 50 Unit c Flat¡rons Resources, LLCGRAND JUNCTlON, CO. 81503 BURVEY BY: jeffdj Survey Date;5-17-12 Job No. 12-41TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTION 4, T19S, R25E, SLB&M, GRANDCOUNTY,UTAH
Federal #1-4LAT:39°11'40.68364"LON:109°08'57.85471"N: 6884138.66E: 2306535.08
0 30 60 120
Scale 1"=60
Pad &cRig Layout - Plot 3Flatirons Federal #1-4
1673 Highway 50 Unit c Flat¡rons Resources, LLCGRAND JUNCTlON, CO. 81503 BURVEY BY: jeffdj Survey Date;5-17-12 Job No. 12-41TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTION 4, T19S, R25E, SLB&M, GRANDCOUNTY,UTAH
Federal #1-4LAT:39°11'40.68364"LON:109°08'57.85471"N: 6884138.66E: 2306535.08
0 30 60 120
Scale 1"=60
Pad &cRig Layout - Plot 3Flatirons Federal #1-4
1673 Highway 50 Unit c Flat¡rons Resources, LLCGRAND JUNCTlON, CO. 81503 BURVEY BY: jeffdj Survey Date;5-17-12 Job No. 12-41TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTION 4, T19S, R25E, SLB&M, GRANDCOUNTY,UTAH
Federal #1-4LAT:39°11'40.68364"LON:109°08'57.85471"N: 6884138.66E: 2306535.08
0 30 60 120
Scale 1"=60
Pad &cRig Layout - Plot 3Flatirons Federal #1-4
1673 Highway 50 Unit c Flat¡rons Resources, LLCGRAND JUNCTlON, CO. 81503 BURVEY BY: jeffdj Survey Date;5-17-12 Job No. 12-41TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
API Well Number: 43019500290000
SECTION 4, T19S, R25E, SLB&M, GRANDCOUNTY,UTAH
Federal #1-4LAT:39°11'40.68364"LON:109°08'57.85471"N: 6884138.66E: 2306535.08
0 30 60 120
Scale 1"=60
Pad &cRig Layout - Plot 3Flatirons Federal #1-4
1673 Highway 50 Unit c Flat¡rons Resources, LLCGRAND JUNCTlON, CO. 81503 BURVEY BY: jeffdj Survey Date;5-17-12 Job No. 12-41TELE: (970) 254-8649, FAX: (970) 241-0451 DRAWNBY: rsk Draft Date:5-21-12 PLAT
RECEIVED: November 14, 2012
ªª
ª
¸
6
ª
ª
ª
ª
6
ª
ª
¸¸
!
0304
33 34
05
10
32
0908
02
35
11
Flatirons Federal 1-4 4301950029
HARLEY DOME 1-X SWD 4301950023HARLEY DOME 1
4301931622
LANSDALE GOVT 3-30-A 4301930260
LANSDALE FEDERAL 2 4301930036
LANSDALE GOVT 15 4301930017
LANSDALE GOVT 13 4301930008
LANSDALE GOVT 9 4301930007
LANSDALE GOVT 6 4301930005
LANSDALE GOVT 4 4301930003
LANSDALE GOVT 1 4301920247
GOVERNMENT 1 4301911576
FEDERAL 2 4301911514
HOME OIL CO 1 4301911513
G R E A T E R C I S C O F I E L DG R E A T E R C I S C O F I E L DH A R L E Y D O M E F I E L DH A R L E Y D O M E F I E L D
Map Produced by Diana MasonMap Prepared:
F1,500 0 1,500750 Feet
1:14,255
UnitsSTATUS
ACTIVE
EXPLORATORY
GAS STORAGE
NF PP OIL
NF SECONDARY
PI OIL
PP GAS
PP GEOTHERML
PP OIL
SECONDARY
TERMINATED
FieldsSTATUS
Unknown
ABANDONED
ACTIVE
COMBINED
INACTIVE
STORAGE
TERMINATED
Wells QueryStatus
APD - Aproved Permit
H DRL - Spuded (Drilling Commenced)
4 GIW - Gas Injection
!* GS - Gas Storage
! LOC - New Location
7 OPS - Operation Suspended
ª PA - Plugged Abandoned
* PGW - Producing Gas Well
' POW - Producing Oil Well
¸ SGW - Shut-in Gas Well
· SOW - Shut-in Oil Well
6 TA - Temp. Abandoned
" TW - Test Well
¸ WDW - Water Disposal
¸ WIW - Water Injection Well
=* WSW - Water Supply Well
â Bottom Hole Location - OilGasDb
TOOELE
SAN JUAN
MILLARD
KANE
JUAB
IRON
EMERY
UINTAH
BOX ELDER
GARFIELD
GRAND
UTAH
WAYNEBEAVER
DUCHESNE
SEVIER
SUMMIT
RICH
WASHINGTON
CARBON
SANPETE
CACHE
PIUTE
DAVIS
WASATCH
WEBER
SALT LAKE
DAGGETT
MORGAN
Location Map
Operator: FLATIRONS RESOURCES, LLC
Well Name: Flatirons Federal 1-4API Number: 4301950029
Township T19.0S Section 04Range R25.0EMeridian: SLBM
API Well Number: 43019500290000
CONFIDE
NTIAL
API Well Number: 43019500290000
G30 9E1R1N5M6ENT1 API Number: 4301950029
LANSDALE GOVT 5 Well Name: Flatirons Federal 1-44301930017 Township T19.0S Range R25.0E Section 04
LANSDALEGOVT6 Meridian: SLBM4301930005 Operator: FLATIRONS RESOURCES, LLC
LANSDALE FEDERAL 24301930036 Map Prepared:
Map Produced by Diana Mason
32 33 34 35
Units WellsQuerySTAlus status
AcrivE # APD-AprovedPerm
LANSDALEGOVT1 ExeLomavaav o Dat-spadeato
4301920247 omssvannes aos assinission
NFsEcaNDARY
PiaiL e Lac-NewLocaion
PPaiL n Pow-Producingcasweii
sEcaNDARYPow-Producingaliweii
TERrviiNATED-D- sow-shut-inoasweii
Fieldssaw-shut-inaliweii
STAlus TA -Temp.Abandoned
LANSDALE GOVT 3-30-A unknow T* 166 *ell
4301930260 ABANooNED wow wateroisposa
HOMEOILCO1Acrive wiw wateriaissionweii
4301911513 Flatirons F eral 1-4 corisioso
# 430195002GRE TER C I SCO F I ELD e +LAN DALEGOVT13 37°R^3E 3°"°msoietocation-aiisasou
+ 4301 30008 TER IN^TED
HARLE DOME FIELD 4F3E0D1ERA5L124
02
0403 ox E' E"
iesLocation Map
05
LANSDALEGOVT9 SUMMI
4301930007 LANSDALE GOVT 44301930003
09
H3
1.500 Feet
i i 1:14,255
RECEIVED: November 14,
API Well Number: 43019500290000
G30 9E1R1N5M6ENT1 API Number: 4301950029
LANSDALE GOVT 5 Well Name: Flatirons Federal 1-44301930017 Township T19.0S Range R25.0E Section 04
LANSDALEGOVT6 Meridian: SLBM4301930005 Operator: FLATIRONS RESOURCES, LLC
LANSDALE FEDERAL 24301930036 Map Prepared:
Map Produced by Diana Mason
32 33 34 35
Units WellsQuerySTAlus status
AcrivE # APD-AprovedPerm
LANSDALEGOVT1 ExeLomavaav o Dat-spadeato
4301920247 omssvannes aos assinission
NFsEcaNDARY
PiaiL e Lac-NewLocaion
PPaiL n Pow-Producingcasweii
sEcaNDARYPow-Producingaliweii
TERrviiNATED-D- sow-shut-inoasweii
Fieldssaw-shut-inaliweii
STAlus TA -Temp.Abandoned
LANSDALE GOVT 3-30-A unknow T* 166 *ell
4301930260 ABANooNED wow wateroisposa
HOMEOILCO1Acrive wiw wateriaissionweii
4301911513 Flatirons F eral 1-4 corisioso
# 430195002GRE TER C I SCO F I ELD e +LAN DALEGOVT13 37°R^3E 3°"°msoietocation-aiisasou
+ 4301 30008 TER IN^TED
HARLE DOME FIELD 4F3E0D1ERA5L124
02
0403 ox E' E"
iesLocation Map
05
LANSDALEGOVT9 SUMMI
4301930007 LANSDALE GOVT 44301930003
09
H3
1.500 Feet
i i 1:14,255
RECEIVED: November 14,
API Well Number: 43019500290000
G30 9E1R1N5M6ENT1 API Number: 4301950029
LANSDALE GOVT 5 Well Name: Flatirons Federal 1-44301930017 Township T19.0S Range R25.0E Section 04
LANSDALEGOVT6 Meridian: SLBM4301930005 Operator: FLATIRONS RESOURCES, LLC
LANSDALE FEDERAL 24301930036 Map Prepared:
Map Produced by Diana Mason
32 33 34 35
Units WellsQuerySTAlus status
AcrivE # APD-AprovedPerm
LANSDALEGOVT1 ExeLomavaav o Dat-spadeato
4301920247 omssvannes aos assinission
NFsEcaNDARY
PiaiL e Lac-NewLocaion
PPaiL n Pow-Producingcasweii
sEcaNDARYPow-Producingaliweii
TERrviiNATED-D- sow-shut-inoasweii
Fieldssaw-shut-inaliweii
STAlus TA -Temp.Abandoned
LANSDALE GOVT 3-30-A unknow T* 166 *ell
4301930260 ABANooNED wow wateroisposa
HOMEOILCO1Acrive wiw wateriaissionweii
4301911513 Flatirons F eral 1-4 corisioso
# 430195002GRE TER C I SCO F I ELD e +LAN DALEGOVT13 37°R^3E 3°"°msoietocation-aiisasou
+ 4301 30008 TER IN^TED
HARLE DOME FIELD 4F3E0D1ERA5L124
02
0403 ox E' E"
iesLocation Map
05
LANSDALEGOVT9 SUMMI
4301930007 LANSDALE GOVT 44301930003
09
H3
1.500 Feet
i i 1:14,255
RECEIVED: November 14,
API Well Number: 43019500290000
G30 9E1R1N5M6ENT1 API Number: 4301950029
LANSDALE GOVT 5 Well Name: Flatirons Federal 1-44301930017 Township T19.0S Range R25.0E Section 04
LANSDALEGOVT6 Meridian: SLBM4301930005 Operator: FLATIRONS RESOURCES, LLC
LANSDALE FEDERAL 24301930036 Map Prepared:
Map Produced by Diana Mason
32 33 34 35
Units WellsQuerySTAlus status
AcrivE # APD-AprovedPerm
LANSDALEGOVT1 ExeLomavaav o Dat-spadeato
4301920247 omssvannes aos assinission
NFsEcaNDARY
PiaiL e Lac-NewLocaion
PPaiL n Pow-Producingcasweii
sEcaNDARYPow-Producingaliweii
TERrviiNATED-D- sow-shut-inoasweii
Fieldssaw-shut-inaliweii
STAlus TA -Temp.Abandoned
LANSDALE GOVT 3-30-A unknow T* 166 *ell
4301930260 ABANooNED wow wateroisposa
HOMEOILCO1Acrive wiw wateriaissionweii
4301911513 Flatirons F eral 1-4 corisioso
# 430195002GRE TER C I SCO F I ELD e +LAN DALEGOVT13 37°R^3E 3°"°msoietocation-aiisasou
+ 4301 30008 TER IN^TED
HARLE DOME FIELD 4F3E0D1ERA5L124
02
0403 ox E' E"
iesLocation Map
05
LANSDALEGOVT9 SUMMI
4301930007 LANSDALE GOVT 44301930003
09
H3
1.500 Feet
i i 1:14,255
RECEIVED: November 14,
API Well Number: 43019500290000
G30 9E1R1N5M6ENT1 API Number: 4301950029
LANSDALE GOVT 5 Well Name: Flatirons Federal 1-44301930017 Township T19.0S Range R25.0E Section 04
LANSDALEGOVT6 Meridian: SLBM4301930005 Operator: FLATIRONS RESOURCES, LLC
LANSDALE FEDERAL 24301930036 Map Prepared:
Map Produced by Diana Mason
32 33 34 35
Units WellsQuerySTAlus status
AcrivE # APD-AprovedPerm
LANSDALEGOVT1 ExeLomavaav o Dat-spadeato
4301920247 omssvannes aos assinission
NFsEcaNDARY
PiaiL e Lac-NewLocaion
PPaiL n Pow-Producingcasweii
sEcaNDARYPow-Producingaliweii
TERrviiNATED-D- sow-shut-inoasweii
Fieldssaw-shut-inaliweii
STAlus TA -Temp.Abandoned
LANSDALE GOVT 3-30-A unknow T* 166 *ell
4301930260 ABANooNED wow wateroisposa
HOMEOILCO1Acrive wiw wateriaissionweii
4301911513 Flatirons F eral 1-4 corisioso
# 430195002GRE TER C I SCO F I ELD e +LAN DALEGOVT13 37°R^3E 3°"°msoietocation-aiisasou
+ 4301 30008 TER IN^TED
HARLE DOME FIELD 4F3E0D1ERA5L124
02
0403 ox E' E"
iesLocation Map
05
LANSDALEGOVT9 SUMMI
4301930007 LANSDALE GOVT 44301930003
09
H3
1.500 Feet
i i 1:14,255
RECEIVED: November 14,
API Well Number: 43019500290000
G30 9E1R1N5M6ENT1 API Number: 4301950029
LANSDALE GOVT 5 Well Name: Flatirons Federal 1-44301930017 Township T19.0S Range R25.0E Section 04
LANSDALEGOVT6 Meridian: SLBM4301930005 Operator: FLATIRONS RESOURCES, LLC
LANSDALE FEDERAL 24301930036 Map Prepared:
Map Produced by Diana Mason
32 33 34 35
Units WellsQuerySTAlus status
AcrivE # APD-AprovedPerm
LANSDALEGOVT1 ExeLomavaav o Dat-spadeato
4301920247 omssvannes aos assinission
NFsEcaNDARY
PiaiL e Lac-NewLocaion
PPaiL n Pow-Producingcasweii
sEcaNDARYPow-Producingaliweii
TERrviiNATED-D- sow-shut-inoasweii
Fieldssaw-shut-inaliweii
STAlus TA -Temp.Abandoned
LANSDALE GOVT 3-30-A unknow T* 166 *ell
4301930260 ABANooNED wow wateroisposa
HOMEOILCO1Acrive wiw wateriaissionweii
4301911513 Flatirons F eral 1-4 corisioso
# 430195002GRE TER C I SCO F I ELD e +LAN DALEGOVT13 37°R^3E 3°"°msoietocation-aiisasou
+ 4301 30008 TER IN^TED
HARLE DOME FIELD 4F3E0D1ERA5L124
02
0403 ox E' E"
iesLocation Map
05
LANSDALEGOVT9 SUMMI
4301930007 LANSDALE GOVT 44301930003
09
H3
1.500 Feet
i i 1:14,255
RECEIVED: November 14,
API Well Number: 43019500290000
G30 9E1R1N5M6ENT1 API Number: 4301950029
LANSDALE GOVT 5 Well Name: Flatirons Federal 1-44301930017 Township T19.0S Range R25.0E Section 04
LANSDALEGOVT6 Meridian: SLBM4301930005 Operator: FLATIRONS RESOURCES, LLC
LANSDALE FEDERAL 24301930036 Map Prepared:
Map Produced by Diana Mason
32 33 34 35
Units WellsQuerySTAlus status
AcrivE # APD-AprovedPerm
LANSDALEGOVT1 ExeLomavaav o Dat-spadeato
4301920247 omssvannes aos assinission
NFsEcaNDARY
PiaiL e Lac-NewLocaion
PPaiL n Pow-Producingcasweii
sEcaNDARYPow-Producingaliweii
TERrviiNATED-D- sow-shut-inoasweii
Fieldssaw-shut-inaliweii
STAlus TA -Temp.Abandoned
LANSDALE GOVT 3-30-A unknow T* 166 *ell
4301930260 ABANooNED wow wateroisposa
HOMEOILCO1Acrive wiw wateriaissionweii
4301911513 Flatirons F eral 1-4 corisioso
# 430195002GRE TER C I SCO F I ELD e +LAN DALEGOVT13 37°R^3E 3°"°msoietocation-aiisasou
+ 4301 30008 TER IN^TED
HARLE DOME FIELD 4F3E0D1ERA5L124
02
0403 ox E' E"
iesLocation Map
05
LANSDALEGOVT9 SUMMI
4301930007 LANSDALE GOVT 44301930003
09
H3
1.500 Feet
i i 1:14,255
RECEIVED: November 14,
API Well Number: 43019500290000
G30 9E1R1N5M6ENT1 API Number: 4301950029
LANSDALE GOVT 5 Well Name: Flatirons Federal 1-44301930017 Township T19.0S Range R25.0E Section 04
LANSDALEGOVT6 Meridian: SLBM4301930005 Operator: FLATIRONS RESOURCES, LLC
LANSDALE FEDERAL 24301930036 Map Prepared:
Map Produced by Diana Mason
32 33 34 35
Units WellsQuerySTAlus status
AcrivE # APD-AprovedPerm
LANSDALEGOVT1 ExeLomavaav o Dat-spadeato
4301920247 omssvannes aos assinission
NFsEcaNDARY
PiaiL e Lac-NewLocaion
PPaiL n Pow-Producingcasweii
sEcaNDARYPow-Producingaliweii
TERrviiNATED-D- sow-shut-inoasweii
Fieldssaw-shut-inaliweii
STAlus TA -Temp.Abandoned
LANSDALE GOVT 3-30-A unknow T* 166 *ell
4301930260 ABANooNED wow wateroisposa
HOMEOILCO1Acrive wiw wateriaissionweii
4301911513 Flatirons F eral 1-4 corisioso
# 430195002GRE TER C I SCO F I ELD e +LAN DALEGOVT13 37°R^3E 3°"°msoietocation-aiisasou
+ 4301 30008 TER IN^TED
HARLE DOME FIELD 4F3E0D1ERA5L124
02
0403 ox E' E"
iesLocation Map
05
LANSDALEGOVT9 SUMMI
4301930007 LANSDALE GOVT 44301930003
09
H3
1.500 Feet
i i 1:14,255
RECEIVED: November 14,
API Well Number: 43019500290000
G30 9E1R1N5M6ENT1 API Number: 4301950029
LANSDALE GOVT 5 Well Name: Flatirons Federal 1-44301930017 Township T19.0S Range R25.0E Section 04
LANSDALEGOVT6 Meridian: SLBM4301930005 Operator: FLATIRONS RESOURCES, LLC
LANSDALE FEDERAL 24301930036 Map Prepared:
Map Produced by Diana Mason
32 33 34 35
Units WellsQuerySTAlus status
AcrivE # APD-AprovedPerm
LANSDALEGOVT1 ExeLomavaav o Dat-spadeato
4301920247 omssvannes aos assinission
NFsEcaNDARY
PiaiL e Lac-NewLocaion
PPaiL n Pow-Producingcasweii
sEcaNDARYPow-Producingaliweii
TERrviiNATED-D- sow-shut-inoasweii
Fieldssaw-shut-inaliweii
STAlus TA -Temp.Abandoned
LANSDALE GOVT 3-30-A unknow T* 166 *ell
4301930260 ABANooNED wow wateroisposa
HOMEOILCO1Acrive wiw wateriaissionweii
4301911513 Flatirons F eral 1-4 corisioso
# 430195002GRE TER C I SCO F I ELD e +LAN DALEGOVT13 37°R^3E 3°"°msoietocation-aiisasou
+ 4301 30008 TER IN^TED
HARLE DOME FIELD 4F3E0D1ERA5L124
02
0403 ox E' E"
iesLocation Map
05
LANSDALEGOVT9 SUMMI
4301930007 LANSDALE GOVT 44301930003
09
H3
1.500 Feet
i i 1:14,255
RECEIVED: November 14,
API Well Number: 43019500290000
G30 9E1R1N5M6ENT1 API Number: 4301950029
LANSDALE GOVT 5 Well Name: Flatirons Federal 1-44301930017 Township T19.0S Range R25.0E Section 04
LANSDALEGOVT6 Meridian: SLBM4301930005 Operator: FLATIRONS RESOURCES, LLC
LANSDALE FEDERAL 24301930036 Map Prepared:
Map Produced by Diana Mason
32 33 34 35
Units WellsQuerySTAlus status
AcrivE # APD-AprovedPerm
LANSDALEGOVT1 ExeLomavaav o Dat-spadeato
4301920247 omssvannes aos assinission
NFsEcaNDARY
PiaiL e Lac-NewLocaion
PPaiL n Pow-Producingcasweii
sEcaNDARYPow-Producingaliweii
TERrviiNATED-D- sow-shut-inoasweii
Fieldssaw-shut-inaliweii
STAlus TA -Temp.Abandoned
LANSDALE GOVT 3-30-A unknow T* 166 *ell
4301930260 ABANooNED wow wateroisposa
HOMEOILCO1Acrive wiw wateriaissionweii
4301911513 Flatirons F eral 1-4 corisioso
# 430195002GRE TER C I SCO F I ELD e +LAN DALEGOVT13 37°R^3E 3°"°msoietocation-aiisasou
+ 4301 30008 TER IN^TED
HARLE DOME FIELD 4F3E0D1ERA5L124
02
0403 ox E' E"
iesLocation Map
05
LANSDALEGOVT9 SUMMI
4301930007 LANSDALE GOVT 44301930003
09
H3
1.500 Feet
i i 1:14,255
RECEIVED: November 14,
API Well Number: 43019500290000
G30 9E1R1N5M6ENT1 API Number: 4301950029
LANSDALE GOVT 5 Well Name: Flatirons Federal 1-44301930017 Township T19.0S Range R25.0E Section 04
LANSDALEGOVT6 Meridian: SLBM4301930005 Operator: FLATIRONS RESOURCES, LLC
LANSDALE FEDERAL 24301930036 Map Prepared:
Map Produced by Diana Mason
32 33 34 35
Units WellsQuerySTAlus status
AcrivE # APD-AprovedPerm
LANSDALEGOVT1 ExeLomavaav o Dat-spadeato
4301920247 omssvannes aos assinission
NFsEcaNDARY
PiaiL e Lac-NewLocaion
PPaiL n Pow-Producingcasweii
sEcaNDARYPow-Producingaliweii
TERrviiNATED-D- sow-shut-inoasweii
Fieldssaw-shut-inaliweii
STAlus TA -Temp.Abandoned
LANSDALE GOVT 3-30-A unknow T* 166 *ell
4301930260 ABANooNED wow wateroisposa
HOMEOILCO1Acrive wiw wateriaissionweii
4301911513 Flatirons F eral 1-4 corisioso
# 430195002GRE TER C I SCO F I ELD e +LAN DALEGOVT13 37°R^3E 3°"°msoietocation-aiisasou
+ 4301 30008 TER IN^TED
HARLE DOME FIELD 4F3E0D1ERA5L124
02
0403 ox E' E"
iesLocation Map
05
LANSDALEGOVT9 SUMMI
4301930007 LANSDALE GOVT 44301930003
09
H3
1.500 Feet
i i 1:14,255
RECEIVED: November 14,
API Well Number: 43019500290000
G30 9E1R1N5M6ENT1 API Number: 4301950029
LANSDALE GOVT 5 Well Name: Flatirons Federal 1-44301930017 Township T19.0S Range R25.0E Section 04
LANSDALEGOVT6 Meridian: SLBM4301930005 Operator: FLATIRONS RESOURCES, LLC
LANSDALE FEDERAL 24301930036 Map Prepared:
Map Produced by Diana Mason
32 33 34 35
Units WellsQuerySTAlus status
AcrivE # APD-AprovedPerm
LANSDALEGOVT1 ExeLomavaav o Dat-spadeato
4301920247 omssvannes aos assinission
NFsEcaNDARY
PiaiL e Lac-NewLocaion
PPaiL n Pow-Producingcasweii
sEcaNDARYPow-Producingaliweii
TERrviiNATED-D- sow-shut-inoasweii
Fieldssaw-shut-inaliweii
STAlus TA -Temp.Abandoned
LANSDALE GOVT 3-30-A unknow T* 166 *ell
4301930260 ABANooNED wow wateroisposa
HOMEOILCO1Acrive wiw wateriaissionweii
4301911513 Flatirons F eral 1-4 corisioso
# 430195002GRE TER C I SCO F I ELD e +LAN DALEGOVT13 37°R^3E 3°"°msoietocation-aiisasou
+ 4301 30008 TER IN^TED
HARLE DOME FIELD 4F3E0D1ERA5L124
02
0403 ox E' E"
iesLocation Map
05
LANSDALEGOVT9 SUMMI
4301930007 LANSDALE GOVT 44301930003
09
H3
1.500 Feet
i i 1:14,255
RECEIVED: November 14,
API Well Number: 43019500290000
G30 9E1R1N5M6ENT1 API Number: 4301950029
LANSDALE GOVT 5 Well Name: Flatirons Federal 1-44301930017 Township T19.0S Range R25.0E Section 04
LANSDALEGOVT6 Meridian: SLBM4301930005 Operator: FLATIRONS RESOURCES, LLC
LANSDALE FEDERAL 24301930036 Map Prepared:
Map Produced by Diana Mason
32 33 34 35
Units WellsQuerySTAlus status
AcrivE # APD-AprovedPerm
LANSDALEGOVT1 ExeLomavaav o Dat-spadeato
4301920247 omssvannes aos assinission
NFsEcaNDARY
PiaiL e Lac-NewLocaion
PPaiL n Pow-Producingcasweii
sEcaNDARYPow-Producingaliweii
TERrviiNATED-D- sow-shut-inoasweii
Fieldssaw-shut-inaliweii
STAlus TA -Temp.Abandoned
LANSDALE GOVT 3-30-A unknow T* 166 *ell
4301930260 ABANooNED wow wateroisposa
HOMEOILCO1Acrive wiw wateriaissionweii
4301911513 Flatirons F eral 1-4 corisioso
# 430195002GRE TER C I SCO F I ELD e +LAN DALEGOVT13 37°R^3E 3°"°msoietocation-aiisasou
+ 4301 30008 TER IN^TED
HARLE DOME FIELD 4F3E0D1ERA5L124
02
0403 ox E' E"
iesLocation Map
05
LANSDALEGOVT9 SUMMI
4301930007 LANSDALE GOVT 44301930003
09
H3
1.500 Feet
i i 1:14,255
RECEIVED: November 14,
API Well Number: 43019500290000
G30 9E1R1N5M6ENT1 API Number: 4301950029
LANSDALE GOVT 5 Well Name: Flatirons Federal 1-44301930017 Township T19.0S Range R25.0E Section 04
LANSDALEGOVT6 Meridian: SLBM4301930005 Operator: FLATIRONS RESOURCES, LLC
LANSDALE FEDERAL 24301930036 Map Prepared:
Map Produced by Diana Mason
32 33 34 35
Units WellsQuerySTAlus status
AcrivE # APD-AprovedPerm
LANSDALEGOVT1 ExeLomavaav o Dat-spadeato
4301920247 omssvannes aos assinission
NFsEcaNDARY
PiaiL e Lac-NewLocaion
PPaiL n Pow-Producingcasweii
sEcaNDARYPow-Producingaliweii
TERrviiNATED-D- sow-shut-inoasweii
Fieldssaw-shut-inaliweii
STAlus TA -Temp.Abandoned
LANSDALE GOVT 3-30-A unknow T* 166 *ell
4301930260 ABANooNED wow wateroisposa
HOMEOILCO1Acrive wiw wateriaissionweii
4301911513 Flatirons F eral 1-4 corisioso
# 430195002GRE TER C I SCO F I ELD e +LAN DALEGOVT13 37°R^3E 3°"°msoietocation-aiisasou
+ 4301 30008 TER IN^TED
HARLE DOME FIELD 4F3E0D1ERA5L124
02
0403 ox E' E"
iesLocation Map
05
LANSDALEGOVT9 SUMMI
4301930007 LANSDALE GOVT 44301930003
09
H3
1.500 Feet
i i 1:14,255
RECEIVED: November 14,
RECEIVED: November 21, 2012
WORKSHEETAPPLICATION FOR PERMIT TO DRILL
APD RECEIVED: 11/12 /2012 API NO. ASSIGNED: 43019500290000
WELL NAME: Flatirons Federal 1-4
OPERATOR: FLATIRONS RESOURCES, LLC (N3915) PHONE NUMBER: 303 292-3902
CONTACT: Sharon Wells
PROPOSED LOCATION: SENE 04 190S 250E Permit Tech Review:
SURFACE: 1402 FNL 0757 FEL Engineering Review:
BOTTOM: 1402 FNL 0757 FEL Geology Review:
COUNTY: GRAND
LATITUDE: 39.18693 LONGITUDE: -109.14789
UTM SURF EASTINGS: 659960.00 NORTHINGS: 4339155.00
FIELD NAME: GREATER CISCO
LEASE TYPE: 1 - Federal
LEASE NUMBER: UTU87659 PROPOSED PRODUCING FORMATION(S): ENTRADA
SURFACE OWNER: 1 - Federal COALBED METHANE: NO
RECEIVED AND/OR REVIEWED: LOCATION AND SITING:
PLAT R649-2 -3 .
Bond: FEDERAL - UTB000511 Unit:
Potash R649-3-2. General
Oil Shale 190-5
Oil Shale 190-3 R649-3-3. Exception
Oil Shale 190-13 Drilling Unit
Water Permit: municipal Board Cause No: Cause 102-16(B)
RDCC Review: Effective Date: 11/15/1979
Fee Surface Agreement Siting: 500' Fr Property Lease line & 200' Fr 1/4 1/4
Intent to Commingle R649-3-11. Directional Drill
Commingling Approved
Comments: Presite Completed
Stipulations: 4 - Federal Approval - bhill
API Well Number: 43019500290000
CONFIDE
NTIAL
API Well Number: 43019500290000
WORKSHEETAPPLICATION FOR PERMIT TO DRILL
I
I
APD RECEIVED: 11/12/2012 API NO. ASSIGNED: 43019500290000
WELL NAME: Flatirons Federal 1-4
OPERATOR: FLATIRONS RESOURCES, LLC(N3915) PHONE NUMBER: 303 292-3902
CONTACT: Sharon Wells
PROPOSED LOCATION: SENE 04 190S 250E Permit Tech Review:
SURFACE: 1402 FNL 0757 FEL Engineering Review:
BOTTOM: 1402 FNL 0757 FEL Geology Review:
COUNTY: GRAND
LATITUDE: 39.18693 LONGITUDE: -109.14789
UTM SURF EASTINGS: 659960.00 NORTHINGS: 4339155.00
FIELD NAME: GREATER CISCO
LEASE TYPE: 1 - Federal
LEASE NUMBER: UTU87659 PROPOSED PRODUCING FORMATION(S): ENTRADA
SURFACE OWNER: 1 - Federal COALBED METHANE: NO
I
RECEIVED ANDIOR REVIEWED: LOCATION AND SITING:
PLAT R649-2-3.
Bond: FEDERAL - UTBOOO511 Unit:
Potash R649-3-2. General
Oil Shale 190-5
Oil Shale 190-3 R649-3-3. Exception
Oil Shale 190-13 Drilling Unit
Water Permit: municipal Board Cause No: Cause 102-16(B)
RDCC Review: Effective Date: 11/15/1979
Fee Surface Agreement Siting: 500' Fr Property Lease line & 200' Fr 1/4 1/4
Intent to Commingle R649-3-11. Directional Drill
Commingling Approved
I
Comments: Presite Completed
Stipulations: 4 - Federal Approval - bhill
RECEIVED: November 21,
API Well Number: 43019500290000
WORKSHEETAPPLICATION FOR PERMIT TO DRILL
I
I
APD RECEIVED: 11/12/2012 API NO. ASSIGNED: 43019500290000
WELL NAME: Flatirons Federal 1-4
OPERATOR: FLATIRONS RESOURCES, LLC(N3915) PHONE NUMBER: 303 292-3902
CONTACT: Sharon Wells
PROPOSED LOCATION: SENE 04 190S 250E Permit Tech Review:
SURFACE: 1402 FNL 0757 FEL Engineering Review:
BOTTOM: 1402 FNL 0757 FEL Geology Review:
COUNTY: GRAND
LATITUDE: 39.18693 LONGITUDE: -109.14789
UTM SURF EASTINGS: 659960.00 NORTHINGS: 4339155.00
FIELD NAME: GREATER CISCO
LEASE TYPE: 1 - Federal
LEASE NUMBER: UTU87659 PROPOSED PRODUCING FORMATION(S): ENTRADA
SURFACE OWNER: 1 - Federal COALBED METHANE: NO
I
RECEIVED ANDIOR REVIEWED: LOCATION AND SITING:
PLAT R649-2-3.
Bond: FEDERAL - UTBOOO511 Unit:
Potash R649-3-2. General
Oil Shale 190-5
Oil Shale 190-3 R649-3-3. Exception
Oil Shale 190-13 Drilling Unit
Water Permit: municipal Board Cause No: Cause 102-16(B)
RDCC Review: Effective Date: 11/15/1979
Fee Surface Agreement Siting: 500' Fr Property Lease line & 200' Fr 1/4 1/4
Intent to Commingle R649-3-11. Directional Drill
Commingling Approved
I
Comments: Presite Completed
Stipulations: 4 - Federal Approval - bhill
RECEIVED: November 21,
API Well Number: 43019500290000
WORKSHEETAPPLICATION FOR PERMIT TO DRILL
I
I
APD RECEIVED: 11/12/2012 API NO. ASSIGNED: 43019500290000
WELL NAME: Flatirons Federal 1-4
OPERATOR: FLATIRONS RESOURCES, LLC(N3915) PHONE NUMBER: 303 292-3902
CONTACT: Sharon Wells
PROPOSED LOCATION: SENE 04 190S 250E Permit Tech Review:
SURFACE: 1402 FNL 0757 FEL Engineering Review:
BOTTOM: 1402 FNL 0757 FEL Geology Review:
COUNTY: GRAND
LATITUDE: 39.18693 LONGITUDE: -109.14789
UTM SURF EASTINGS: 659960.00 NORTHINGS: 4339155.00
FIELD NAME: GREATER CISCO
LEASE TYPE: 1 - Federal
LEASE NUMBER: UTU87659 PROPOSED PRODUCING FORMATION(S): ENTRADA
SURFACE OWNER: 1 - Federal COALBED METHANE: NO
I
RECEIVED ANDIOR REVIEWED: LOCATION AND SITING:
PLAT R649-2-3.
Bond: FEDERAL - UTBOOO511 Unit:
Potash R649-3-2. General
Oil Shale 190-5
Oil Shale 190-3 R649-3-3. Exception
Oil Shale 190-13 Drilling Unit
Water Permit: municipal Board Cause No: Cause 102-16(B)
RDCC Review: Effective Date: 11/15/1979
Fee Surface Agreement Siting: 500' Fr Property Lease line & 200' Fr 1/4 1/4
Intent to Commingle R649-3-11. Directional Drill
Commingling Approved
I
Comments: Presite Completed
Stipulations: 4 - Federal Approval - bhill
RECEIVED: November 21,
API Well Number: 43019500290000
WORKSHEETAPPLICATION FOR PERMIT TO DRILL
I
I
APD RECEIVED: 11/12/2012 API NO. ASSIGNED: 43019500290000
WELL NAME: Flatirons Federal 1-4
OPERATOR: FLATIRONS RESOURCES, LLC(N3915) PHONE NUMBER: 303 292-3902
CONTACT: Sharon Wells
PROPOSED LOCATION: SENE 04 190S 250E Permit Tech Review:
SURFACE: 1402 FNL 0757 FEL Engineering Review:
BOTTOM: 1402 FNL 0757 FEL Geology Review:
COUNTY: GRAND
LATITUDE: 39.18693 LONGITUDE: -109.14789
UTM SURF EASTINGS: 659960.00 NORTHINGS: 4339155.00
FIELD NAME: GREATER CISCO
LEASE TYPE: 1 - Federal
LEASE NUMBER: UTU87659 PROPOSED PRODUCING FORMATION(S): ENTRADA
SURFACE OWNER: 1 - Federal COALBED METHANE: NO
I
RECEIVED ANDIOR REVIEWED: LOCATION AND SITING:
PLAT R649-2-3.
Bond: FEDERAL - UTBOOO511 Unit:
Potash R649-3-2. General
Oil Shale 190-5
Oil Shale 190-3 R649-3-3. Exception
Oil Shale 190-13 Drilling Unit
Water Permit: municipal Board Cause No: Cause 102-16(B)
RDCC Review: Effective Date: 11/15/1979
Fee Surface Agreement Siting: 500' Fr Property Lease line & 200' Fr 1/4 1/4
Intent to Commingle R649-3-11. Directional Drill
Commingling Approved
I
Comments: Presite Completed
Stipulations: 4 - Federal Approval - bhill
RECEIVED: November 21,
API Well Number: 43019500290000
WORKSHEETAPPLICATION FOR PERMIT TO DRILL
I
I
APD RECEIVED: 11/12/2012 API NO. ASSIGNED: 43019500290000
WELL NAME: Flatirons Federal 1-4
OPERATOR: FLATIRONS RESOURCES, LLC(N3915) PHONE NUMBER: 303 292-3902
CONTACT: Sharon Wells
PROPOSED LOCATION: SENE 04 190S 250E Permit Tech Review:
SURFACE: 1402 FNL 0757 FEL Engineering Review:
BOTTOM: 1402 FNL 0757 FEL Geology Review:
COUNTY: GRAND
LATITUDE: 39.18693 LONGITUDE: -109.14789
UTM SURF EASTINGS: 659960.00 NORTHINGS: 4339155.00
FIELD NAME: GREATER CISCO
LEASE TYPE: 1 - Federal
LEASE NUMBER: UTU87659 PROPOSED PRODUCING FORMATION(S): ENTRADA
SURFACE OWNER: 1 - Federal COALBED METHANE: NO
I
RECEIVED ANDIOR REVIEWED: LOCATION AND SITING:
PLAT R649-2-3.
Bond: FEDERAL - UTBOOO511 Unit:
Potash R649-3-2. General
Oil Shale 190-5
Oil Shale 190-3 R649-3-3. Exception
Oil Shale 190-13 Drilling Unit
Water Permit: municipal Board Cause No: Cause 102-16(B)
RDCC Review: Effective Date: 11/15/1979
Fee Surface Agreement Siting: 500' Fr Property Lease line & 200' Fr 1/4 1/4
Intent to Commingle R649-3-11. Directional Drill
Commingling Approved
I
Comments: Presite Completed
Stipulations: 4 - Federal Approval - bhill
RECEIVED: November 21,
API Well Number: 43019500290000
WORKSHEETAPPLICATION FOR PERMIT TO DRILL
I
I
APD RECEIVED: 11/12/2012 API NO. ASSIGNED: 43019500290000
WELL NAME: Flatirons Federal 1-4
OPERATOR: FLATIRONS RESOURCES, LLC(N3915) PHONE NUMBER: 303 292-3902
CONTACT: Sharon Wells
PROPOSED LOCATION: SENE 04 190S 250E Permit Tech Review:
SURFACE: 1402 FNL 0757 FEL Engineering Review:
BOTTOM: 1402 FNL 0757 FEL Geology Review:
COUNTY: GRAND
LATITUDE: 39.18693 LONGITUDE: -109.14789
UTM SURF EASTINGS: 659960.00 NORTHINGS: 4339155.00
FIELD NAME: GREATER CISCO
LEASE TYPE: 1 - Federal
LEASE NUMBER: UTU87659 PROPOSED PRODUCING FORMATION(S): ENTRADA
SURFACE OWNER: 1 - Federal COALBED METHANE: NO
I
RECEIVED ANDIOR REVIEWED: LOCATION AND SITING:
PLAT R649-2-3.
Bond: FEDERAL - UTBOOO511 Unit:
Potash R649-3-2. General
Oil Shale 190-5
Oil Shale 190-3 R649-3-3. Exception
Oil Shale 190-13 Drilling Unit
Water Permit: municipal Board Cause No: Cause 102-16(B)
RDCC Review: Effective Date: 11/15/1979
Fee Surface Agreement Siting: 500' Fr Property Lease line & 200' Fr 1/4 1/4
Intent to Commingle R649-3-11. Directional Drill
Commingling Approved
I
Comments: Presite Completed
Stipulations: 4 - Federal Approval - bhill
RECEIVED: November 21,
API Well Number: 43019500290000
WORKSHEETAPPLICATION FOR PERMIT TO DRILL
I
I
APD RECEIVED: 11/12/2012 API NO. ASSIGNED: 43019500290000
WELL NAME: Flatirons Federal 1-4
OPERATOR: FLATIRONS RESOURCES, LLC(N3915) PHONE NUMBER: 303 292-3902
CONTACT: Sharon Wells
PROPOSED LOCATION: SENE 04 190S 250E Permit Tech Review:
SURFACE: 1402 FNL 0757 FEL Engineering Review:
BOTTOM: 1402 FNL 0757 FEL Geology Review:
COUNTY: GRAND
LATITUDE: 39.18693 LONGITUDE: -109.14789
UTM SURF EASTINGS: 659960.00 NORTHINGS: 4339155.00
FIELD NAME: GREATER CISCO
LEASE TYPE: 1 - Federal
LEASE NUMBER: UTU87659 PROPOSED PRODUCING FORMATION(S): ENTRADA
SURFACE OWNER: 1 - Federal COALBED METHANE: NO
I
RECEIVED ANDIOR REVIEWED: LOCATION AND SITING:
PLAT R649-2-3.
Bond: FEDERAL - UTBOOO511 Unit:
Potash R649-3-2. General
Oil Shale 190-5
Oil Shale 190-3 R649-3-3. Exception
Oil Shale 190-13 Drilling Unit
Water Permit: municipal Board Cause No: Cause 102-16(B)
RDCC Review: Effective Date: 11/15/1979
Fee Surface Agreement Siting: 500' Fr Property Lease line & 200' Fr 1/4 1/4
Intent to Commingle R649-3-11. Directional Drill
Commingling Approved
I
Comments: Presite Completed
Stipulations: 4 - Federal Approval - bhill
RECEIVED: November 21,
API Well Number: 43019500290000
WORKSHEETAPPLICATION FOR PERMIT TO DRILL
I
I
APD RECEIVED: 11/12/2012 API NO. ASSIGNED: 43019500290000
WELL NAME: Flatirons Federal 1-4
OPERATOR: FLATIRONS RESOURCES, LLC(N3915) PHONE NUMBER: 303 292-3902
CONTACT: Sharon Wells
PROPOSED LOCATION: SENE 04 190S 250E Permit Tech Review:
SURFACE: 1402 FNL 0757 FEL Engineering Review:
BOTTOM: 1402 FNL 0757 FEL Geology Review:
COUNTY: GRAND
LATITUDE: 39.18693 LONGITUDE: -109.14789
UTM SURF EASTINGS: 659960.00 NORTHINGS: 4339155.00
FIELD NAME: GREATER CISCO
LEASE TYPE: 1 - Federal
LEASE NUMBER: UTU87659 PROPOSED PRODUCING FORMATION(S): ENTRADA
SURFACE OWNER: 1 - Federal COALBED METHANE: NO
I
RECEIVED ANDIOR REVIEWED: LOCATION AND SITING:
PLAT R649-2-3.
Bond: FEDERAL - UTBOOO511 Unit:
Potash R649-3-2. General
Oil Shale 190-5
Oil Shale 190-3 R649-3-3. Exception
Oil Shale 190-13 Drilling Unit
Water Permit: municipal Board Cause No: Cause 102-16(B)
RDCC Review: Effective Date: 11/15/1979
Fee Surface Agreement Siting: 500' Fr Property Lease line & 200' Fr 1/4 1/4
Intent to Commingle R649-3-11. Directional Drill
Commingling Approved
I
Comments: Presite Completed
Stipulations: 4 - Federal Approval - bhill
RECEIVED: November 21,
API Well Number: 43019500290000
WORKSHEETAPPLICATION FOR PERMIT TO DRILL
I
I
APD RECEIVED: 11/12/2012 API NO. ASSIGNED: 43019500290000
WELL NAME: Flatirons Federal 1-4
OPERATOR: FLATIRONS RESOURCES, LLC(N3915) PHONE NUMBER: 303 292-3902
CONTACT: Sharon Wells
PROPOSED LOCATION: SENE 04 190S 250E Permit Tech Review:
SURFACE: 1402 FNL 0757 FEL Engineering Review:
BOTTOM: 1402 FNL 0757 FEL Geology Review:
COUNTY: GRAND
LATITUDE: 39.18693 LONGITUDE: -109.14789
UTM SURF EASTINGS: 659960.00 NORTHINGS: 4339155.00
FIELD NAME: GREATER CISCO
LEASE TYPE: 1 - Federal
LEASE NUMBER: UTU87659 PROPOSED PRODUCING FORMATION(S): ENTRADA
SURFACE OWNER: 1 - Federal COALBED METHANE: NO
I
RECEIVED ANDIOR REVIEWED: LOCATION AND SITING:
PLAT R649-2-3.
Bond: FEDERAL - UTBOOO511 Unit:
Potash R649-3-2. General
Oil Shale 190-5
Oil Shale 190-3 R649-3-3. Exception
Oil Shale 190-13 Drilling Unit
Water Permit: municipal Board Cause No: Cause 102-16(B)
RDCC Review: Effective Date: 11/15/1979
Fee Surface Agreement Siting: 500' Fr Property Lease line & 200' Fr 1/4 1/4
Intent to Commingle R649-3-11. Directional Drill
Commingling Approved
I
Comments: Presite Completed
Stipulations: 4 - Federal Approval - bhill
RECEIVED: November 21,
API Well Number: 43019500290000
WORKSHEETAPPLICATION FOR PERMIT TO DRILL
I
I
APD RECEIVED: 11/12/2012 API NO. ASSIGNED: 43019500290000
WELL NAME: Flatirons Federal 1-4
OPERATOR: FLATIRONS RESOURCES, LLC(N3915) PHONE NUMBER: 303 292-3902
CONTACT: Sharon Wells
PROPOSED LOCATION: SENE 04 190S 250E Permit Tech Review:
SURFACE: 1402 FNL 0757 FEL Engineering Review:
BOTTOM: 1402 FNL 0757 FEL Geology Review:
COUNTY: GRAND
LATITUDE: 39.18693 LONGITUDE: -109.14789
UTM SURF EASTINGS: 659960.00 NORTHINGS: 4339155.00
FIELD NAME: GREATER CISCO
LEASE TYPE: 1 - Federal
LEASE NUMBER: UTU87659 PROPOSED PRODUCING FORMATION(S): ENTRADA
SURFACE OWNER: 1 - Federal COALBED METHANE: NO
I
RECEIVED ANDIOR REVIEWED: LOCATION AND SITING:
PLAT R649-2-3.
Bond: FEDERAL - UTBOOO511 Unit:
Potash R649-3-2. General
Oil Shale 190-5
Oil Shale 190-3 R649-3-3. Exception
Oil Shale 190-13 Drilling Unit
Water Permit: municipal Board Cause No: Cause 102-16(B)
RDCC Review: Effective Date: 11/15/1979
Fee Surface Agreement Siting: 500' Fr Property Lease line & 200' Fr 1/4 1/4
Intent to Commingle R649-3-11. Directional Drill
Commingling Approved
I
Comments: Presite Completed
Stipulations: 4 - Federal Approval - bhill
RECEIVED: November 21,
API Well Number: 43019500290000
WORKSHEETAPPLICATION FOR PERMIT TO DRILL
I
I
APD RECEIVED: 11/12/2012 API NO. ASSIGNED: 43019500290000
WELL NAME: Flatirons Federal 1-4
OPERATOR: FLATIRONS RESOURCES, LLC(N3915) PHONE NUMBER: 303 292-3902
CONTACT: Sharon Wells
PROPOSED LOCATION: SENE 04 190S 250E Permit Tech Review:
SURFACE: 1402 FNL 0757 FEL Engineering Review:
BOTTOM: 1402 FNL 0757 FEL Geology Review:
COUNTY: GRAND
LATITUDE: 39.18693 LONGITUDE: -109.14789
UTM SURF EASTINGS: 659960.00 NORTHINGS: 4339155.00
FIELD NAME: GREATER CISCO
LEASE TYPE: 1 - Federal
LEASE NUMBER: UTU87659 PROPOSED PRODUCING FORMATION(S): ENTRADA
SURFACE OWNER: 1 - Federal COALBED METHANE: NO
I
RECEIVED ANDIOR REVIEWED: LOCATION AND SITING:
PLAT R649-2-3.
Bond: FEDERAL - UTBOOO511 Unit:
Potash R649-3-2. General
Oil Shale 190-5
Oil Shale 190-3 R649-3-3. Exception
Oil Shale 190-13 Drilling Unit
Water Permit: municipal Board Cause No: Cause 102-16(B)
RDCC Review: Effective Date: 11/15/1979
Fee Surface Agreement Siting: 500' Fr Property Lease line & 200' Fr 1/4 1/4
Intent to Commingle R649-3-11. Directional Drill
Commingling Approved
I
Comments: Presite Completed
Stipulations: 4 - Federal Approval - bhill
RECEIVED: November 21,
API Well Number: 43019500290000
WORKSHEETAPPLICATION FOR PERMIT TO DRILL
I
I
APD RECEIVED: 11/12/2012 API NO. ASSIGNED: 43019500290000
WELL NAME: Flatirons Federal 1-4
OPERATOR: FLATIRONS RESOURCES, LLC(N3915) PHONE NUMBER: 303 292-3902
CONTACT: Sharon Wells
PROPOSED LOCATION: SENE 04 190S 250E Permit Tech Review:
SURFACE: 1402 FNL 0757 FEL Engineering Review:
BOTTOM: 1402 FNL 0757 FEL Geology Review:
COUNTY: GRAND
LATITUDE: 39.18693 LONGITUDE: -109.14789
UTM SURF EASTINGS: 659960.00 NORTHINGS: 4339155.00
FIELD NAME: GREATER CISCO
LEASE TYPE: 1 - Federal
LEASE NUMBER: UTU87659 PROPOSED PRODUCING FORMATION(S): ENTRADA
SURFACE OWNER: 1 - Federal COALBED METHANE: NO
I
RECEIVED ANDIOR REVIEWED: LOCATION AND SITING:
PLAT R649-2-3.
Bond: FEDERAL - UTBOOO511 Unit:
Potash R649-3-2. General
Oil Shale 190-5
Oil Shale 190-3 R649-3-3. Exception
Oil Shale 190-13 Drilling Unit
Water Permit: municipal Board Cause No: Cause 102-16(B)
RDCC Review: Effective Date: 11/15/1979
Fee Surface Agreement Siting: 500' Fr Property Lease line & 200' Fr 1/4 1/4
Intent to Commingle R649-3-11. Directional Drill
Commingling Approved
I
Comments: Presite Completed
Stipulations: 4 - Federal Approval - bhill
RECEIVED: November 21,
API Well Number: 43019500290000
WORKSHEETAPPLICATION FOR PERMIT TO DRILL
I
I
APD RECEIVED: 11/12/2012 API NO. ASSIGNED: 43019500290000
WELL NAME: Flatirons Federal 1-4
OPERATOR: FLATIRONS RESOURCES, LLC(N3915) PHONE NUMBER: 303 292-3902
CONTACT: Sharon Wells
PROPOSED LOCATION: SENE 04 190S 250E Permit Tech Review:
SURFACE: 1402 FNL 0757 FEL Engineering Review:
BOTTOM: 1402 FNL 0757 FEL Geology Review:
COUNTY: GRAND
LATITUDE: 39.18693 LONGITUDE: -109.14789
UTM SURF EASTINGS: 659960.00 NORTHINGS: 4339155.00
FIELD NAME: GREATER CISCO
LEASE TYPE: 1 - Federal
LEASE NUMBER: UTU87659 PROPOSED PRODUCING FORMATION(S): ENTRADA
SURFACE OWNER: 1 - Federal COALBED METHANE: NO
I
RECEIVED ANDIOR REVIEWED: LOCATION AND SITING:
PLAT R649-2-3.
Bond: FEDERAL - UTBOOO511 Unit:
Potash R649-3-2. General
Oil Shale 190-5
Oil Shale 190-3 R649-3-3. Exception
Oil Shale 190-13 Drilling Unit
Water Permit: municipal Board Cause No: Cause 102-16(B)
RDCC Review: Effective Date: 11/15/1979
Fee Surface Agreement Siting: 500' Fr Property Lease line & 200' Fr 1/4 1/4
Intent to Commingle R649-3-11. Directional Drill
Commingling Approved
I
Comments: Presite Completed
Stipulations: 4 - Federal Approval - bhill
RECEIVED: November 21,
API Well Number: 43019500290000
WORKSHEETAPPLICATION FOR PERMIT TO DRILL
I
I
APD RECEIVED: 11/12/2012 API NO. ASSIGNED: 43019500290000
WELL NAME: Flatirons Federal 1-4
OPERATOR: FLATIRONS RESOURCES, LLC(N3915) PHONE NUMBER: 303 292-3902
CONTACT: Sharon Wells
PROPOSED LOCATION: SENE 04 190S 250E Permit Tech Review:
SURFACE: 1402 FNL 0757 FEL Engineering Review:
BOTTOM: 1402 FNL 0757 FEL Geology Review:
COUNTY: GRAND
LATITUDE: 39.18693 LONGITUDE: -109.14789
UTM SURF EASTINGS: 659960.00 NORTHINGS: 4339155.00
FIELD NAME: GREATER CISCO
LEASE TYPE: 1 - Federal
LEASE NUMBER: UTU87659 PROPOSED PRODUCING FORMATION(S): ENTRADA
SURFACE OWNER: 1 - Federal COALBED METHANE: NO
I
RECEIVED ANDIOR REVIEWED: LOCATION AND SITING:
PLAT R649-2-3.
Bond: FEDERAL - UTBOOO511 Unit:
Potash R649-3-2. General
Oil Shale 190-5
Oil Shale 190-3 R649-3-3. Exception
Oil Shale 190-13 Drilling Unit
Water Permit: municipal Board Cause No: Cause 102-16(B)
RDCC Review: Effective Date: 11/15/1979
Fee Surface Agreement Siting: 500' Fr Property Lease line & 200' Fr 1/4 1/4
Intent to Commingle R649-3-11. Directional Drill
Commingling Approved
I
Comments: Presite Completed
Stipulations: 4 - Federal Approval - bhill
RECEIVED: November 21,
Permit To Drill******************
Well Name: Flatirons Federal 1-4API Well Number: 43019500290000
Lease Number: UTU87659Surface Owner: FEDERAL Approval Date: 1 1 / 2 1 / 2 0 1 2
Issued to:FLATIRONS RESOURCES, LLC, 303 E. 17th Ave, Denver, CO 80203
Authority:Pursuant to Utah Code Ann. 40-6-1 et seq. , and Utah Administrat ive CodeR649-3-1 et seq., the Utah Division of Oil, Gas and Mining issues conditions ofapproval, and permit to drill the listed well. This permit is issued in accordancewith the requirements of Cause 102-16(B). The expected producing formation orpool is the ENTRADA Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than onepool will require approval in accordance with R649-3-22.
Duration:This approval shall expire one year from the above date unless substantial andcontinuous operat ion is underway, or a request for extension is made prior to theexpirat ion date
General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and GasConservation General Rules, and the applicable terms and provisions of theapproved Application for permit to dril l .
Conditions of Approval:State approval of this well does not supercede the required federal approval, whichmust be obtained prior to dri l l ing.
Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of thefollowing actions during drilling of this well: • Within 24 hours following the spudding of the well - contact Carol Daniels at8 0 1 - 5 3 8 - 5 2 8 4 (please leave a voicemail message if not available) OR submit an electronic sundry notice (pre-registration required) via the Utah Oil &Gas website at ht tp:/ /oi lgas.ogm.utah.gov
State of UtahDEPARTMENT OF NATURAL RESOURCES
- -/ MICHAELR.STYLER
GAR'R H BERTExoutimDrotor
comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director
Permit To Drillkkkkkkkkkkkkkkkkkk
Well Name: Flatirons Federal 1-4API Well Number: 43019500290000
Lease Number: UTU87659Surface Owner: FEDERALApproval Date: 11/21/2012
Issued to:FLATIRONS RESOURCES, LLC, 303 E. 17th Ave, Denver, CO 80203
Authority:Pursuant to Utah Code Ann. 40-6-1 et seq., and Utah Administrative CodeR649-3-1 et seq., the Utah Division of Oil, Gas and Mining issues conditions ofapproval, and permit to drill the listed well. This permit is issued in accordancewith the requirements of Cause 102-16(B). The expected producing formation orpool is the ENTRADA Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than onepool will require approval in accordance with R649-3-22.
Duration:This approval shall expire one year from the above date unless substantial andcontinuous operation is underway, or a request for extension is made prior to theexpiration date
General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and GasConservation General Rules, and the applicable terms and provisions of theapproved Application for permit to drill.
Conditions of Approval:State approval of this well does not supercede the required federal approval, whichmust be obtained prior to drilling.
Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of thefollowing actions during drilling of this well:
• Within 24 hours following the spudding of the well - contact Carol Daniels at801-538-5284
(please leave a voicemail message if not available)ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil &
Gas websiteat
State of UtahDEPARTMENT OF NATURAL RESOURCES
- -/ MICHAELR.STYLER
GAR'R H BERTExoutimDrotor
comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director
Permit To Drillkkkkkkkkkkkkkkkkkk
Well Name: Flatirons Federal 1-4API Well Number: 43019500290000
Lease Number: UTU87659Surface Owner: FEDERALApproval Date: 11/21/2012
Issued to:FLATIRONS RESOURCES, LLC, 303 E. 17th Ave, Denver, CO 80203
Authority:Pursuant to Utah Code Ann. 40-6-1 et seq., and Utah Administrative CodeR649-3-1 et seq., the Utah Division of Oil, Gas and Mining issues conditions ofapproval, and permit to drill the listed well. This permit is issued in accordancewith the requirements of Cause 102-16(B). The expected producing formation orpool is the ENTRADA Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than onepool will require approval in accordance with R649-3-22.
Duration:This approval shall expire one year from the above date unless substantial andcontinuous operation is underway, or a request for extension is made prior to theexpiration date
General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and GasConservation General Rules, and the applicable terms and provisions of theapproved Application for permit to drill.
Conditions of Approval:State approval of this well does not supercede the required federal approval, whichmust be obtained prior to drilling.
Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of thefollowing actions during drilling of this well:
• Within 24 hours following the spudding of the well - contact Carol Daniels at801-538-5284
(please leave a voicemail message if not available)ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil &
Gas websiteat
State of UtahDEPARTMENT OF NATURAL RESOURCES
- -/ MICHAELR.STYLER
GAR'R H BERTExoutimDrotor
comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director
Permit To Drillkkkkkkkkkkkkkkkkkk
Well Name: Flatirons Federal 1-4API Well Number: 43019500290000
Lease Number: UTU87659Surface Owner: FEDERALApproval Date: 11/21/2012
Issued to:FLATIRONS RESOURCES, LLC, 303 E. 17th Ave, Denver, CO 80203
Authority:Pursuant to Utah Code Ann. 40-6-1 et seq., and Utah Administrative CodeR649-3-1 et seq., the Utah Division of Oil, Gas and Mining issues conditions ofapproval, and permit to drill the listed well. This permit is issued in accordancewith the requirements of Cause 102-16(B). The expected producing formation orpool is the ENTRADA Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than onepool will require approval in accordance with R649-3-22.
Duration:This approval shall expire one year from the above date unless substantial andcontinuous operation is underway, or a request for extension is made prior to theexpiration date
General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and GasConservation General Rules, and the applicable terms and provisions of theapproved Application for permit to drill.
Conditions of Approval:State approval of this well does not supercede the required federal approval, whichmust be obtained prior to drilling.
Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of thefollowing actions during drilling of this well:
• Within 24 hours following the spudding of the well - contact Carol Daniels at801-538-5284
(please leave a voicemail message if not available)ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil &
Gas websiteat
State of UtahDEPARTMENT OF NATURAL RESOURCES
- -/ MICHAELR.STYLER
GAR'R H BERTExoutimDrotor
comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director
Permit To Drillkkkkkkkkkkkkkkkkkk
Well Name: Flatirons Federal 1-4API Well Number: 43019500290000
Lease Number: UTU87659Surface Owner: FEDERALApproval Date: 11/21/2012
Issued to:FLATIRONS RESOURCES, LLC, 303 E. 17th Ave, Denver, CO 80203
Authority:Pursuant to Utah Code Ann. 40-6-1 et seq., and Utah Administrative CodeR649-3-1 et seq., the Utah Division of Oil, Gas and Mining issues conditions ofapproval, and permit to drill the listed well. This permit is issued in accordancewith the requirements of Cause 102-16(B). The expected producing formation orpool is the ENTRADA Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than onepool will require approval in accordance with R649-3-22.
Duration:This approval shall expire one year from the above date unless substantial andcontinuous operation is underway, or a request for extension is made prior to theexpiration date
General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and GasConservation General Rules, and the applicable terms and provisions of theapproved Application for permit to drill.
Conditions of Approval:State approval of this well does not supercede the required federal approval, whichmust be obtained prior to drilling.
Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of thefollowing actions during drilling of this well:
• Within 24 hours following the spudding of the well - contact Carol Daniels at801-538-5284
(please leave a voicemail message if not available)ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil &
Gas websiteat
State of UtahDEPARTMENT OF NATURAL RESOURCES
- -/ MICHAELR.STYLER
GAR'R H BERTExoutimDrotor
comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director
Permit To Drillkkkkkkkkkkkkkkkkkk
Well Name: Flatirons Federal 1-4API Well Number: 43019500290000
Lease Number: UTU87659Surface Owner: FEDERALApproval Date: 11/21/2012
Issued to:FLATIRONS RESOURCES, LLC, 303 E. 17th Ave, Denver, CO 80203
Authority:Pursuant to Utah Code Ann. 40-6-1 et seq., and Utah Administrative CodeR649-3-1 et seq., the Utah Division of Oil, Gas and Mining issues conditions ofapproval, and permit to drill the listed well. This permit is issued in accordancewith the requirements of Cause 102-16(B). The expected producing formation orpool is the ENTRADA Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than onepool will require approval in accordance with R649-3-22.
Duration:This approval shall expire one year from the above date unless substantial andcontinuous operation is underway, or a request for extension is made prior to theexpiration date
General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and GasConservation General Rules, and the applicable terms and provisions of theapproved Application for permit to drill.
Conditions of Approval:State approval of this well does not supercede the required federal approval, whichmust be obtained prior to drilling.
Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of thefollowing actions during drilling of this well:
• Within 24 hours following the spudding of the well - contact Carol Daniels at801-538-5284
(please leave a voicemail message if not available)ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil &
Gas websiteat
State of UtahDEPARTMENT OF NATURAL RESOURCES
- -/ MICHAELR.STYLER
GAR'R H BERTExoutimDrotor
comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director
Permit To Drillkkkkkkkkkkkkkkkkkk
Well Name: Flatirons Federal 1-4API Well Number: 43019500290000
Lease Number: UTU87659Surface Owner: FEDERALApproval Date: 11/21/2012
Issued to:FLATIRONS RESOURCES, LLC, 303 E. 17th Ave, Denver, CO 80203
Authority:Pursuant to Utah Code Ann. 40-6-1 et seq., and Utah Administrative CodeR649-3-1 et seq., the Utah Division of Oil, Gas and Mining issues conditions ofapproval, and permit to drill the listed well. This permit is issued in accordancewith the requirements of Cause 102-16(B). The expected producing formation orpool is the ENTRADA Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than onepool will require approval in accordance with R649-3-22.
Duration:This approval shall expire one year from the above date unless substantial andcontinuous operation is underway, or a request for extension is made prior to theexpiration date
General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and GasConservation General Rules, and the applicable terms and provisions of theapproved Application for permit to drill.
Conditions of Approval:State approval of this well does not supercede the required federal approval, whichmust be obtained prior to drilling.
Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of thefollowing actions during drilling of this well:
• Within 24 hours following the spudding of the well - contact Carol Daniels at801-538-5284
(please leave a voicemail message if not available)ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil &
Gas websiteat
State of UtahDEPARTMENT OF NATURAL RESOURCES
- -/ MICHAELR.STYLER
GAR'R H BERTExoutimDrotor
comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director
Permit To Drillkkkkkkkkkkkkkkkkkk
Well Name: Flatirons Federal 1-4API Well Number: 43019500290000
Lease Number: UTU87659Surface Owner: FEDERALApproval Date: 11/21/2012
Issued to:FLATIRONS RESOURCES, LLC, 303 E. 17th Ave, Denver, CO 80203
Authority:Pursuant to Utah Code Ann. 40-6-1 et seq., and Utah Administrative CodeR649-3-1 et seq., the Utah Division of Oil, Gas and Mining issues conditions ofapproval, and permit to drill the listed well. This permit is issued in accordancewith the requirements of Cause 102-16(B). The expected producing formation orpool is the ENTRADA Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than onepool will require approval in accordance with R649-3-22.
Duration:This approval shall expire one year from the above date unless substantial andcontinuous operation is underway, or a request for extension is made prior to theexpiration date
General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and GasConservation General Rules, and the applicable terms and provisions of theapproved Application for permit to drill.
Conditions of Approval:State approval of this well does not supercede the required federal approval, whichmust be obtained prior to drilling.
Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of thefollowing actions during drilling of this well:
• Within 24 hours following the spudding of the well - contact Carol Daniels at801-538-5284
(please leave a voicemail message if not available)ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil &
Gas websiteat
State of UtahDEPARTMENT OF NATURAL RESOURCES
- -/ MICHAELR.STYLER
GAR'R H BERTExoutimDrotor
comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director
Permit To Drillkkkkkkkkkkkkkkkkkk
Well Name: Flatirons Federal 1-4API Well Number: 43019500290000
Lease Number: UTU87659Surface Owner: FEDERALApproval Date: 11/21/2012
Issued to:FLATIRONS RESOURCES, LLC, 303 E. 17th Ave, Denver, CO 80203
Authority:Pursuant to Utah Code Ann. 40-6-1 et seq., and Utah Administrative CodeR649-3-1 et seq., the Utah Division of Oil, Gas and Mining issues conditions ofapproval, and permit to drill the listed well. This permit is issued in accordancewith the requirements of Cause 102-16(B). The expected producing formation orpool is the ENTRADA Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than onepool will require approval in accordance with R649-3-22.
Duration:This approval shall expire one year from the above date unless substantial andcontinuous operation is underway, or a request for extension is made prior to theexpiration date
General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and GasConservation General Rules, and the applicable terms and provisions of theapproved Application for permit to drill.
Conditions of Approval:State approval of this well does not supercede the required federal approval, whichmust be obtained prior to drilling.
Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of thefollowing actions during drilling of this well:
• Within 24 hours following the spudding of the well - contact Carol Daniels at801-538-5284
(please leave a voicemail message if not available)ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil &
Gas websiteat
State of UtahDEPARTMENT OF NATURAL RESOURCES
- -/ MICHAELR.STYLER
GAR'R H BERTExoutimDrotor
comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director
Permit To Drillkkkkkkkkkkkkkkkkkk
Well Name: Flatirons Federal 1-4API Well Number: 43019500290000
Lease Number: UTU87659Surface Owner: FEDERALApproval Date: 11/21/2012
Issued to:FLATIRONS RESOURCES, LLC, 303 E. 17th Ave, Denver, CO 80203
Authority:Pursuant to Utah Code Ann. 40-6-1 et seq., and Utah Administrative CodeR649-3-1 et seq., the Utah Division of Oil, Gas and Mining issues conditions ofapproval, and permit to drill the listed well. This permit is issued in accordancewith the requirements of Cause 102-16(B). The expected producing formation orpool is the ENTRADA Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than onepool will require approval in accordance with R649-3-22.
Duration:This approval shall expire one year from the above date unless substantial andcontinuous operation is underway, or a request for extension is made prior to theexpiration date
General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and GasConservation General Rules, and the applicable terms and provisions of theapproved Application for permit to drill.
Conditions of Approval:State approval of this well does not supercede the required federal approval, whichmust be obtained prior to drilling.
Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of thefollowing actions during drilling of this well:
• Within 24 hours following the spudding of the well - contact Carol Daniels at801-538-5284
(please leave a voicemail message if not available)ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil &
Gas websiteat
State of UtahDEPARTMENT OF NATURAL RESOURCES
- -/ MICHAELR.STYLER
GAR'R H BERTExoutimDrotor
comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director
Permit To Drillkkkkkkkkkkkkkkkkkk
Well Name: Flatirons Federal 1-4API Well Number: 43019500290000
Lease Number: UTU87659Surface Owner: FEDERALApproval Date: 11/21/2012
Issued to:FLATIRONS RESOURCES, LLC, 303 E. 17th Ave, Denver, CO 80203
Authority:Pursuant to Utah Code Ann. 40-6-1 et seq., and Utah Administrative CodeR649-3-1 et seq., the Utah Division of Oil, Gas and Mining issues conditions ofapproval, and permit to drill the listed well. This permit is issued in accordancewith the requirements of Cause 102-16(B). The expected producing formation orpool is the ENTRADA Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than onepool will require approval in accordance with R649-3-22.
Duration:This approval shall expire one year from the above date unless substantial andcontinuous operation is underway, or a request for extension is made prior to theexpiration date
General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and GasConservation General Rules, and the applicable terms and provisions of theapproved Application for permit to drill.
Conditions of Approval:State approval of this well does not supercede the required federal approval, whichmust be obtained prior to drilling.
Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of thefollowing actions during drilling of this well:
• Within 24 hours following the spudding of the well - contact Carol Daniels at801-538-5284
(please leave a voicemail message if not available)ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil &
Gas websiteat
State of UtahDEPARTMENT OF NATURAL RESOURCES
- -/ MICHAELR.STYLER
GAR'R H BERTExoutimDrotor
comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director
Permit To Drillkkkkkkkkkkkkkkkkkk
Well Name: Flatirons Federal 1-4API Well Number: 43019500290000
Lease Number: UTU87659Surface Owner: FEDERALApproval Date: 11/21/2012
Issued to:FLATIRONS RESOURCES, LLC, 303 E. 17th Ave, Denver, CO 80203
Authority:Pursuant to Utah Code Ann. 40-6-1 et seq., and Utah Administrative CodeR649-3-1 et seq., the Utah Division of Oil, Gas and Mining issues conditions ofapproval, and permit to drill the listed well. This permit is issued in accordancewith the requirements of Cause 102-16(B). The expected producing formation orpool is the ENTRADA Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than onepool will require approval in accordance with R649-3-22.
Duration:This approval shall expire one year from the above date unless substantial andcontinuous operation is underway, or a request for extension is made prior to theexpiration date
General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and GasConservation General Rules, and the applicable terms and provisions of theapproved Application for permit to drill.
Conditions of Approval:State approval of this well does not supercede the required federal approval, whichmust be obtained prior to drilling.
Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of thefollowing actions during drilling of this well:
• Within 24 hours following the spudding of the well - contact Carol Daniels at801-538-5284
(please leave a voicemail message if not available)ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil &
Gas websiteat
State of UtahDEPARTMENT OF NATURAL RESOURCES
- -/ MICHAELR.STYLER
GAR'R H BERTExoutimDrotor
comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director
Permit To Drillkkkkkkkkkkkkkkkkkk
Well Name: Flatirons Federal 1-4API Well Number: 43019500290000
Lease Number: UTU87659Surface Owner: FEDERALApproval Date: 11/21/2012
Issued to:FLATIRONS RESOURCES, LLC, 303 E. 17th Ave, Denver, CO 80203
Authority:Pursuant to Utah Code Ann. 40-6-1 et seq., and Utah Administrative CodeR649-3-1 et seq., the Utah Division of Oil, Gas and Mining issues conditions ofapproval, and permit to drill the listed well. This permit is issued in accordancewith the requirements of Cause 102-16(B). The expected producing formation orpool is the ENTRADA Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than onepool will require approval in accordance with R649-3-22.
Duration:This approval shall expire one year from the above date unless substantial andcontinuous operation is underway, or a request for extension is made prior to theexpiration date
General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and GasConservation General Rules, and the applicable terms and provisions of theapproved Application for permit to drill.
Conditions of Approval:State approval of this well does not supercede the required federal approval, whichmust be obtained prior to drilling.
Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of thefollowing actions during drilling of this well:
• Within 24 hours following the spudding of the well - contact Carol Daniels at801-538-5284
(please leave a voicemail message if not available)ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil &
Gas websiteat
State of UtahDEPARTMENT OF NATURAL RESOURCES
- -/ MICHAELR.STYLER
GAR'R H BERTExoutimDrotor
comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director
Permit To Drillkkkkkkkkkkkkkkkkkk
Well Name: Flatirons Federal 1-4API Well Number: 43019500290000
Lease Number: UTU87659Surface Owner: FEDERALApproval Date: 11/21/2012
Issued to:FLATIRONS RESOURCES, LLC, 303 E. 17th Ave, Denver, CO 80203
Authority:Pursuant to Utah Code Ann. 40-6-1 et seq., and Utah Administrative CodeR649-3-1 et seq., the Utah Division of Oil, Gas and Mining issues conditions ofapproval, and permit to drill the listed well. This permit is issued in accordancewith the requirements of Cause 102-16(B). The expected producing formation orpool is the ENTRADA Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than onepool will require approval in accordance with R649-3-22.
Duration:This approval shall expire one year from the above date unless substantial andcontinuous operation is underway, or a request for extension is made prior to theexpiration date
General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and GasConservation General Rules, and the applicable terms and provisions of theapproved Application for permit to drill.
Conditions of Approval:State approval of this well does not supercede the required federal approval, whichmust be obtained prior to drilling.
Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of thefollowing actions during drilling of this well:
• Within 24 hours following the spudding of the well - contact Carol Daniels at801-538-5284
(please leave a voicemail message if not available)ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil &
Gas websiteat
State of UtahDEPARTMENT OF NATURAL RESOURCES
- -/ MICHAELR.STYLER
GAR'R H BERTExoutimDrotor
comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director
Permit To Drillkkkkkkkkkkkkkkkkkk
Well Name: Flatirons Federal 1-4API Well Number: 43019500290000
Lease Number: UTU87659Surface Owner: FEDERALApproval Date: 11/21/2012
Issued to:FLATIRONS RESOURCES, LLC, 303 E. 17th Ave, Denver, CO 80203
Authority:Pursuant to Utah Code Ann. 40-6-1 et seq., and Utah Administrative CodeR649-3-1 et seq., the Utah Division of Oil, Gas and Mining issues conditions ofapproval, and permit to drill the listed well. This permit is issued in accordancewith the requirements of Cause 102-16(B). The expected producing formation orpool is the ENTRADA Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than onepool will require approval in accordance with R649-3-22.
Duration:This approval shall expire one year from the above date unless substantial andcontinuous operation is underway, or a request for extension is made prior to theexpiration date
General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and GasConservation General Rules, and the applicable terms and provisions of theapproved Application for permit to drill.
Conditions of Approval:State approval of this well does not supercede the required federal approval, whichmust be obtained prior to drilling.
Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of thefollowing actions during drilling of this well:
• Within 24 hours following the spudding of the well - contact Carol Daniels at801-538-5284
(please leave a voicemail message if not available)ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil &
Gas websiteat
Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas ConservationGeneral Rules will be promptly filed with the Division of Oil, Gas and Mining,including but not l imited to: • Entity Action Form (Form 6) - due within 5 days of spudding the well • Monthly Status Report (Form 9) - due by 5th day of the following calendarm o n t h • Requests to Change Plans (Form 9) - due prior to implementation • Written Notice of Emergency Changes (Form 9) - due within 5 days • Notice of Operations Suspension or Resumption (Form 9) - due prior toimplementa t ion • Report of Water Encountered (Form 7) - due within 30 days after completion • Well Completion Report (Form 8) - due within 30 days after completion orplugging
Approved By:
For John RogersAssociate Director, Oil & Gas
Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas ConservationGeneral Rules will be promptly filed with the Division of Oil, Gas and Mining,including but not limited to:
• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar
month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to
implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or
plugging
Approved By:
For John RogersAssociate Director, Oil &
Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas ConservationGeneral Rules will be promptly filed with the Division of Oil, Gas and Mining,including but not limited to:
• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar
month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to
implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or
plugging
Approved By:
For John RogersAssociate Director, Oil &
Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas ConservationGeneral Rules will be promptly filed with the Division of Oil, Gas and Mining,including but not limited to:
• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar
month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to
implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or
plugging
Approved By:
For John RogersAssociate Director, Oil &
Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas ConservationGeneral Rules will be promptly filed with the Division of Oil, Gas and Mining,including but not limited to:
• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar
month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to
implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or
plugging
Approved By:
For John RogersAssociate Director, Oil &
Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas ConservationGeneral Rules will be promptly filed with the Division of Oil, Gas and Mining,including but not limited to:
• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar
month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to
implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or
plugging
Approved By:
For John RogersAssociate Director, Oil &
Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas ConservationGeneral Rules will be promptly filed with the Division of Oil, Gas and Mining,including but not limited to:
• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar
month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to
implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or
plugging
Approved By:
For John RogersAssociate Director, Oil &
Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas ConservationGeneral Rules will be promptly filed with the Division of Oil, Gas and Mining,including but not limited to:
• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar
month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to
implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or
plugging
Approved By:
For John RogersAssociate Director, Oil &
Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas ConservationGeneral Rules will be promptly filed with the Division of Oil, Gas and Mining,including but not limited to:
• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar
month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to
implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or
plugging
Approved By:
For John RogersAssociate Director, Oil &
Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas ConservationGeneral Rules will be promptly filed with the Division of Oil, Gas and Mining,including but not limited to:
• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar
month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to
implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or
plugging
Approved By:
For John RogersAssociate Director, Oil &
Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas ConservationGeneral Rules will be promptly filed with the Division of Oil, Gas and Mining,including but not limited to:
• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar
month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to
implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or
plugging
Approved By:
For John RogersAssociate Director, Oil &
Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas ConservationGeneral Rules will be promptly filed with the Division of Oil, Gas and Mining,including but not limited to:
• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar
month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to
implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or
plugging
Approved By:
For John RogersAssociate Director, Oil &
Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas ConservationGeneral Rules will be promptly filed with the Division of Oil, Gas and Mining,including but not limited to:
• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar
month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to
implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or
plugging
Approved By:
For John RogersAssociate Director, Oil &
Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas ConservationGeneral Rules will be promptly filed with the Division of Oil, Gas and Mining,including but not limited to:
• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar
month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to
implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or
plugging
Approved By:
For John RogersAssociate Director, Oil &
Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas ConservationGeneral Rules will be promptly filed with the Division of Oil, Gas and Mining,including but not limited to:
• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar
month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to
implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or
plugging
Approved By:
For John RogersAssociate Director, Oil &
CONFilENTIAL
DIVISION OF OIL, GAS AND MINING
SPUDDING INFORMATION
Name of Company; FLATIRONS RESOUCES
Well Name: FLATIRONS FEDERAL 1-4
Api No: 43-019-50029 Lease Type FEDERAL
Section 04 Township 19S Range 25E County GRAND
Drilling Contractor HINES DRILLING RIG # 10
SPUDDED:Date 08/06/2013
Time 5:00 PM
How DRY
Drilling wi/I Commence:
Reported by
Telephone # (724) 840-7695
Date 07/31/2013 Signed
CONFilENTIAL
DIVISION OF OIL, GAS AND MINING
SPUDDING INFORMATION
Name of Company; FLATIRONS RESOUCES
Well Name: FLATIRONS FEDERAL 1-4
Api No: 43-019-50029 Lease Type FEDERAL
Section 04 Township 19S Range 25E County GRAND
Drilling Contractor HINES DRILLING RIG # 10
SPUDDED:Date 08/06/2013
Time 5:00 PM
How DRY
Drilling wi/I Commence:
Reported by
Telephone # (724) 840-7695
Date 07/31/2013 Signed
CONFilENTIAL
DIVISION OF OIL, GAS AND MINING
SPUDDING INFORMATION
Name of Company; FLATIRONS RESOUCES
Well Name: FLATIRONS FEDERAL 1-4
Api No: 43-019-50029 Lease Type FEDERAL
Section 04 Township 19S Range 25E County GRAND
Drilling Contractor HINES DRILLING RIG # 10
SPUDDED:Date 08/06/2013
Time 5:00 PM
How DRY
Drilling wi/I Commence:
Reported by
Telephone # (724) 840-7695
Date 07/31/2013 Signed
CONFilENTIAL
DIVISION OF OIL, GAS AND MINING
SPUDDING INFORMATION
Name of Company; FLATIRONS RESOUCES
Well Name: FLATIRONS FEDERAL 1-4
Api No: 43-019-50029 Lease Type FEDERAL
Section 04 Township 19S Range 25E County GRAND
Drilling Contractor HINES DRILLING RIG # 10
SPUDDED:Date 08/06/2013
Time 5:00 PM
How DRY
Drilling wi/I Commence:
Reported by
Telephone # (724) 840-7695
Date 07/31/2013 Signed
CONFilENTIAL
DIVISION OF OIL, GAS AND MINING
SPUDDING INFORMATION
Name of Company; FLATIRONS RESOUCES
Well Name: FLATIRONS FEDERAL 1-4
Api No: 43-019-50029 Lease Type FEDERAL
Section 04 Township 19S Range 25E County GRAND
Drilling Contractor HINES DRILLING RIG # 10
SPUDDED:Date 08/06/2013
Time 5:00 PM
How DRY
Drilling wi/I Commence:
Reported by
Telephone # (724) 840-7695
Date 07/31/2013 Signed
CONFilENTIAL
DIVISION OF OIL, GAS AND MINING
SPUDDING INFORMATION
Name of Company; FLATIRONS RESOUCES
Well Name: FLATIRONS FEDERAL 1-4
Api No: 43-019-50029 Lease Type FEDERAL
Section 04 Township 19S Range 25E County GRAND
Drilling Contractor HINES DRILLING RIG # 10
SPUDDED:Date 08/06/2013
Time 5:00 PM
How DRY
Drilling wi/I Commence:
Reported by
Telephone # (724) 840-7695
Date 07/31/2013 Signed
CONFilENTIAL
DIVISION OF OIL, GAS AND MINING
SPUDDING INFORMATION
Name of Company; FLATIRONS RESOUCES
Well Name: FLATIRONS FEDERAL 1-4
Api No: 43-019-50029 Lease Type FEDERAL
Section 04 Township 19S Range 25E County GRAND
Drilling Contractor HINES DRILLING RIG # 10
SPUDDED:Date 08/06/2013
Time 5:00 PM
How DRY
Drilling wi/I Commence:
Reported by
Telephone # (724) 840-7695
Date 07/31/2013 Signed
CONFilENTIAL
DIVISION OF OIL, GAS AND MINING
SPUDDING INFORMATION
Name of Company; FLATIRONS RESOUCES
Well Name: FLATIRONS FEDERAL 1-4
Api No: 43-019-50029 Lease Type FEDERAL
Section 04 Township 19S Range 25E County GRAND
Drilling Contractor HINES DRILLING RIG # 10
SPUDDED:Date 08/06/2013
Time 5:00 PM
How DRY
Drilling wi/I Commence:
Reported by
Telephone # (724) 840-7695
Date 07/31/2013 Signed
CONFilENTIAL
DIVISION OF OIL, GAS AND MINING
SPUDDING INFORMATION
Name of Company; FLATIRONS RESOUCES
Well Name: FLATIRONS FEDERAL 1-4
Api No: 43-019-50029 Lease Type FEDERAL
Section 04 Township 19S Range 25E County GRAND
Drilling Contractor HINES DRILLING RIG # 10
SPUDDED:Date 08/06/2013
Time 5:00 PM
How DRY
Drilling wi/I Commence:
Reported by
Telephone # (724) 840-7695
Date 07/31/2013 Signed
CONFilENTIAL
DIVISION OF OIL, GAS AND MINING
SPUDDING INFORMATION
Name of Company; FLATIRONS RESOUCES
Well Name: FLATIRONS FEDERAL 1-4
Api No: 43-019-50029 Lease Type FEDERAL
Section 04 Township 19S Range 25E County GRAND
Drilling Contractor HINES DRILLING RIG # 10
SPUDDED:Date 08/06/2013
Time 5:00 PM
How DRY
Drilling wi/I Commence:
Reported by
Telephone # (724) 840-7695
Date 07/31/2013 Signed
CONFilENTIAL
DIVISION OF OIL, GAS AND MINING
SPUDDING INFORMATION
Name of Company; FLATIRONS RESOUCES
Well Name: FLATIRONS FEDERAL 1-4
Api No: 43-019-50029 Lease Type FEDERAL
Section 04 Township 19S Range 25E County GRAND
Drilling Contractor HINES DRILLING RIG # 10
SPUDDED:Date 08/06/2013
Time 5:00 PM
How DRY
Drilling wi/I Commence:
Reported by
Telephone # (724) 840-7695
Date 07/31/2013 Signed
CONFilENTIAL
DIVISION OF OIL, GAS AND MINING
SPUDDING INFORMATION
Name of Company; FLATIRONS RESOUCES
Well Name: FLATIRONS FEDERAL 1-4
Api No: 43-019-50029 Lease Type FEDERAL
Section 04 Township 19S Range 25E County GRAND
Drilling Contractor HINES DRILLING RIG # 10
SPUDDED:Date 08/06/2013
Time 5:00 PM
How DRY
Drilling wi/I Commence:
Reported by
Telephone # (724) 840-7695
Date 07/31/2013 Signed
CONFilENTIAL
DIVISION OF OIL, GAS AND MINING
SPUDDING INFORMATION
Name of Company; FLATIRONS RESOUCES
Well Name: FLATIRONS FEDERAL 1-4
Api No: 43-019-50029 Lease Type FEDERAL
Section 04 Township 19S Range 25E County GRAND
Drilling Contractor HINES DRILLING RIG # 10
SPUDDED:Date 08/06/2013
Time 5:00 PM
How DRY
Drilling wi/I Commence:
Reported by
Telephone # (724) 840-7695
Date 07/31/2013 Signed
CONFilENTIAL
DIVISION OF OIL, GAS AND MINING
SPUDDING INFORMATION
Name of Company; FLATIRONS RESOUCES
Well Name: FLATIRONS FEDERAL 1-4
Api No: 43-019-50029 Lease Type FEDERAL
Section 04 Township 19S Range 25E County GRAND
Drilling Contractor HINES DRILLING RIG # 10
SPUDDED:Date 08/06/2013
Time 5:00 PM
How DRY
Drilling wi/I Commence:
Reported by
Telephone # (724) 840-7695
Date 07/31/2013 Signed
RECEIVED: Sep. 05, 2013
API Well Number: 43019500290000
STATE OF UTAH AMENDEDREPORT FORM 8DEPARTMENT OF NATURAL RESOURCES (highlight changes)
D1VISION OF OIL, GAS AND MIN1NG 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF LNDIAN, ALLOTTEE OR TRIBE NAME
WELL COMPLETION OR RECOMPLETION REPORT AND LOG18. TYPE OF WELL: OW
LLWA
L DRY OTHan helium 7. UNITorCA AGREEMENT NAME
b. TYPE OF WORK: 8. WELL NAMEand NUMBER:NWEE HOR EP-
TRY RS . OTHER Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER
Flatirons Resources LLC 43019500293. ADDRESS OF DPERATOR: PHONE MUMBER: 10 FIELDANDPOOL, OR WILDCAT
11080 Circle Point Rd #6 Westminster - CO 80020 (303) 292-3902 Harley Dome4. LOCATIONOF WELL(FOOTAGES) 11. OTRIOTR, SECTION, TOWNSHIP, RANGE,
MERfDIAN:AT SURFACE: 1402' FNL 757' FEL SENE 4 19S 25EAT TOP PRODUCING IMTERVAL REPORTED BELOW: VOft|CS WO|
12. COUNTY 13. STATEAT TOTALDEPTH: VertÍCal WelÎ Grand UTAH
14. DATESPUDDED: 15. DATE T.D. REACHED: 16. DATE COMPLETED: 17. ELEVATIONS(DF, RKB, RT, GL).
8/6/2013 8/12/2013 8/14/2013 ABANDONED READYTO PRODUCE Z 4945 GL18. TOTALDEPTH: MD 965 19. PLUG BACKT.D : MD 20. IF MULTIPLECOMPLETIONS, HOW MANY7* 21. DEPTH BRIOGE MD
PLUGSET:TVD TVD TVO
22. TYPE ELECTRICANDOTHER MECHANICALLOGS RUN (Submit copyofeach) 23.
Array induction/Density/ Neutron/Gamma Ray WASWELLCORED? NO YES (Submitanalysis)
WAS DST RUN7 NO YES (Submit repod)
DIRECTIONALSURVEY? NO YES (Submitcopy)
24. CASINGAND LINERRECORD (Report all strings set In well)
HOLE S1ZE SIZEIGRADE WEIGHT (#lft.) TOP (MD) BOTTOM (MD)$TAGE CEMHENTER CNEME
SA S VOL M BBL} CEMENTTOP " AMOUNT PULLED
12 1/4 9 5/6 N-40 32.3 0 264 Class § 65 120 08 3/4 7 J-55 26 595 868 classg 81 506 868 965
25. TUBING RECORD
DEPTH SET (MD) PACKER SET (MD) SfZE DEPTH SET (MD) PACKER SET (MD) SIZE DEPTH SET (MD) PACKER SET (MD)
25. PRODUCING INTERVALS 27. PERFORATION RECORD
FORMATIONNAME TOP (MD} BOTTOM(MD) TOP (TVD) BOTTOM(TVD) INTERVAL(ToplBot - MD) SizE NO.HOLE$ PERFORATION STATU$
(A) Entrada 868 965 open Squeezed
(B) Open Squeezed
(C) Open Squeezed
(D) Open Squeezed
28. ACID,FRACTURE, TREATMENT,CEMENTSQLIEEZE,ETC.
WAS WELL HYORAULICALLYFRACTURED? YES NO IF YES - DATE FRACTURED:
OEPTH INTERVAL AMOUNTANDTYPEOF MATERIAL
29, ENCLO5ED ATTACHMENTS: 30. WELL STATUS:
ELECTRICAUMECHANICALLOGB GEOLOGIC REPORT DST REPORT DIRECTIONALSURVEY
O StJNDRY NOTICE FOR PLUGG1NGANDCEMENT VERIFLCATION CORE ANALYSIS DTHER:
(Sr2o13) (CONTINUED ON
STATE OF UTAH AMENDEDREPORT FORM 8DEPARTMENT OF NATURAL RESOURCES (highlight changes)
D1VISION OF OIL, GAS AND MIN1NG 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF LNDIAN, ALLOTTEE OR TRIBE NAME
WELL COMPLETION OR RECOMPLETION REPORT AND LOG18. TYPE OF WELL: OW
LLWA
L DRY OTHan helium 7. UNITorCA AGREEMENT NAME
b. TYPE OF WORK: 8. WELL NAMEand NUMBER:NWEE HOR EP-
TRY RS . OTHER Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER
Flatirons Resources LLC 43019500293. ADDRESS OF DPERATOR: PHONE MUMBER: 10 FIELDANDPOOL, OR WILDCAT
11080 Circle Point Rd #6 Westminster - CO 80020 (303) 292-3902 Harley Dome4. LOCATIONOF WELL(FOOTAGES) 11. OTRIOTR, SECTION, TOWNSHIP, RANGE,
MERfDIAN:AT SURFACE: 1402' FNL 757' FEL SENE 4 19S 25EAT TOP PRODUCING IMTERVAL REPORTED BELOW: VOft|CS WO|
12. COUNTY 13. STATEAT TOTALDEPTH: VertÍCal WelÎ Grand UTAH
14. DATESPUDDED: 15. DATE T.D. REACHED: 16. DATE COMPLETED: 17. ELEVATIONS(DF, RKB, RT, GL).
8/6/2013 8/12/2013 8/14/2013 ABANDONED READYTO PRODUCE Z 4945 GL18. TOTALDEPTH: MD 965 19. PLUG BACKT.D : MD 20. IF MULTIPLECOMPLETIONS, HOW MANY7* 21. DEPTH BRIOGE MD
PLUGSET:TVD TVD TVO
22. TYPE ELECTRICANDOTHER MECHANICALLOGS RUN (Submit copyofeach) 23.
Array induction/Density/ Neutron/Gamma Ray WASWELLCORED? NO YES (Submitanalysis)
WAS DST RUN7 NO YES (Submit repod)
DIRECTIONALSURVEY? NO YES (Submitcopy)
24. CASINGAND LINERRECORD (Report all strings set In well)
HOLE S1ZE SIZEIGRADE WEIGHT (#lft.) TOP (MD) BOTTOM (MD)$TAGE CEMHENTER CNEME
SA S VOL M BBL} CEMENTTOP " AMOUNT PULLED
12 1/4 9 5/6 N-40 32.3 0 264 Class § 65 120 08 3/4 7 J-55 26 595 868 classg 81 506 868 965
25. TUBING RECORD
DEPTH SET (MD) PACKER SET (MD) SfZE DEPTH SET (MD) PACKER SET (MD) SIZE DEPTH SET (MD) PACKER SET (MD)
25. PRODUCING INTERVALS 27. PERFORATION RECORD
FORMATIONNAME TOP (MD} BOTTOM(MD) TOP (TVD) BOTTOM(TVD) INTERVAL(ToplBot - MD) SizE NO.HOLE$ PERFORATION STATU$
(A) Entrada 868 965 open Squeezed
(B) Open Squeezed
(C) Open Squeezed
(D) Open Squeezed
28. ACID,FRACTURE, TREATMENT,CEMENTSQLIEEZE,ETC.
WAS WELL HYORAULICALLYFRACTURED? YES NO IF YES - DATE FRACTURED:
OEPTH INTERVAL AMOUNTANDTYPEOF MATERIAL
29, ENCLO5ED ATTACHMENTS: 30. WELL STATUS:
ELECTRICAUMECHANICALLOGB GEOLOGIC REPORT DST REPORT DIRECTIONALSURVEY
O StJNDRY NOTICE FOR PLUGG1NGANDCEMENT VERIFLCATION CORE ANALYSIS DTHER:
(Sr2o13) (CONTINUED ON
STATE OF UTAH AMENDEDREPORT FORM 8DEPARTMENT OF NATURAL RESOURCES (highlight changes)
D1VISION OF OIL, GAS AND MIN1NG 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF LNDIAN, ALLOTTEE OR TRIBE NAME
WELL COMPLETION OR RECOMPLETION REPORT AND LOG18. TYPE OF WELL: OW
LLWA
L DRY OTHan helium 7. UNITorCA AGREEMENT NAME
b. TYPE OF WORK: 8. WELL NAMEand NUMBER:NWEE HOR EP-
TRY RS . OTHER Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER
Flatirons Resources LLC 43019500293. ADDRESS OF DPERATOR: PHONE MUMBER: 10 FIELDANDPOOL, OR WILDCAT
11080 Circle Point Rd #6 Westminster - CO 80020 (303) 292-3902 Harley Dome4. LOCATIONOF WELL(FOOTAGES) 11. OTRIOTR, SECTION, TOWNSHIP, RANGE,
MERfDIAN:AT SURFACE: 1402' FNL 757' FEL SENE 4 19S 25EAT TOP PRODUCING IMTERVAL REPORTED BELOW: VOft|CS WO|
12. COUNTY 13. STATEAT TOTALDEPTH: VertÍCal WelÎ Grand UTAH
14. DATESPUDDED: 15. DATE T.D. REACHED: 16. DATE COMPLETED: 17. ELEVATIONS(DF, RKB, RT, GL).
8/6/2013 8/12/2013 8/14/2013 ABANDONED READYTO PRODUCE Z 4945 GL18. TOTALDEPTH: MD 965 19. PLUG BACKT.D : MD 20. IF MULTIPLECOMPLETIONS, HOW MANY7* 21. DEPTH BRIOGE MD
PLUGSET:TVD TVD TVO
22. TYPE ELECTRICANDOTHER MECHANICALLOGS RUN (Submit copyofeach) 23.
Array induction/Density/ Neutron/Gamma Ray WASWELLCORED? NO YES (Submitanalysis)
WAS DST RUN7 NO YES (Submit repod)
DIRECTIONALSURVEY? NO YES (Submitcopy)
24. CASINGAND LINERRECORD (Report all strings set In well)
HOLE S1ZE SIZEIGRADE WEIGHT (#lft.) TOP (MD) BOTTOM (MD)$TAGE CEMHENTER CNEME
SA S VOL M BBL} CEMENTTOP " AMOUNT PULLED
12 1/4 9 5/6 N-40 32.3 0 264 Class § 65 120 08 3/4 7 J-55 26 595 868 classg 81 506 868 965
25. TUBING RECORD
DEPTH SET (MD) PACKER SET (MD) SfZE DEPTH SET (MD) PACKER SET (MD) SIZE DEPTH SET (MD) PACKER SET (MD)
25. PRODUCING INTERVALS 27. PERFORATION RECORD
FORMATIONNAME TOP (MD} BOTTOM(MD) TOP (TVD) BOTTOM(TVD) INTERVAL(ToplBot - MD) SizE NO.HOLE$ PERFORATION STATU$
(A) Entrada 868 965 open Squeezed
(B) Open Squeezed
(C) Open Squeezed
(D) Open Squeezed
28. ACID,FRACTURE, TREATMENT,CEMENTSQLIEEZE,ETC.
WAS WELL HYORAULICALLYFRACTURED? YES NO IF YES - DATE FRACTURED:
OEPTH INTERVAL AMOUNTANDTYPEOF MATERIAL
29, ENCLO5ED ATTACHMENTS: 30. WELL STATUS:
ELECTRICAUMECHANICALLOGB GEOLOGIC REPORT DST REPORT DIRECTIONALSURVEY
O StJNDRY NOTICE FOR PLUGG1NGANDCEMENT VERIFLCATION CORE ANALYSIS DTHER:
(Sr2o13) (CONTINUED ON
STATE OF UTAH AMENDEDREPORT FORM 8DEPARTMENT OF NATURAL RESOURCES (highlight changes)
D1VISION OF OIL, GAS AND MIN1NG 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF LNDIAN, ALLOTTEE OR TRIBE NAME
WELL COMPLETION OR RECOMPLETION REPORT AND LOG18. TYPE OF WELL: OW
LLWA
L DRY OTHan helium 7. UNITorCA AGREEMENT NAME
b. TYPE OF WORK: 8. WELL NAMEand NUMBER:NWEE HOR EP-
TRY RS . OTHER Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER
Flatirons Resources LLC 43019500293. ADDRESS OF DPERATOR: PHONE MUMBER: 10 FIELDANDPOOL, OR WILDCAT
11080 Circle Point Rd #6 Westminster - CO 80020 (303) 292-3902 Harley Dome4. LOCATIONOF WELL(FOOTAGES) 11. OTRIOTR, SECTION, TOWNSHIP, RANGE,
MERfDIAN:AT SURFACE: 1402' FNL 757' FEL SENE 4 19S 25EAT TOP PRODUCING IMTERVAL REPORTED BELOW: VOft|CS WO|
12. COUNTY 13. STATEAT TOTALDEPTH: VertÍCal WelÎ Grand UTAH
14. DATESPUDDED: 15. DATE T.D. REACHED: 16. DATE COMPLETED: 17. ELEVATIONS(DF, RKB, RT, GL).
8/6/2013 8/12/2013 8/14/2013 ABANDONED READYTO PRODUCE Z 4945 GL18. TOTALDEPTH: MD 965 19. PLUG BACKT.D : MD 20. IF MULTIPLECOMPLETIONS, HOW MANY7* 21. DEPTH BRIOGE MD
PLUGSET:TVD TVD TVO
22. TYPE ELECTRICANDOTHER MECHANICALLOGS RUN (Submit copyofeach) 23.
Array induction/Density/ Neutron/Gamma Ray WASWELLCORED? NO YES (Submitanalysis)
WAS DST RUN7 NO YES (Submit repod)
DIRECTIONALSURVEY? NO YES (Submitcopy)
24. CASINGAND LINERRECORD (Report all strings set In well)
HOLE S1ZE SIZEIGRADE WEIGHT (#lft.) TOP (MD) BOTTOM (MD)$TAGE CEMHENTER CNEME
SA S VOL M BBL} CEMENTTOP " AMOUNT PULLED
12 1/4 9 5/6 N-40 32.3 0 264 Class § 65 120 08 3/4 7 J-55 26 595 868 classg 81 506 868 965
25. TUBING RECORD
DEPTH SET (MD) PACKER SET (MD) SfZE DEPTH SET (MD) PACKER SET (MD) SIZE DEPTH SET (MD) PACKER SET (MD)
25. PRODUCING INTERVALS 27. PERFORATION RECORD
FORMATIONNAME TOP (MD} BOTTOM(MD) TOP (TVD) BOTTOM(TVD) INTERVAL(ToplBot - MD) SizE NO.HOLE$ PERFORATION STATU$
(A) Entrada 868 965 open Squeezed
(B) Open Squeezed
(C) Open Squeezed
(D) Open Squeezed
28. ACID,FRACTURE, TREATMENT,CEMENTSQLIEEZE,ETC.
WAS WELL HYORAULICALLYFRACTURED? YES NO IF YES - DATE FRACTURED:
OEPTH INTERVAL AMOUNTANDTYPEOF MATERIAL
29, ENCLO5ED ATTACHMENTS: 30. WELL STATUS:
ELECTRICAUMECHANICALLOGB GEOLOGIC REPORT DST REPORT DIRECTIONALSURVEY
O StJNDRY NOTICE FOR PLUGG1NGANDCEMENT VERIFLCATION CORE ANALYSIS DTHER:
(Sr2o13) (CONTINUED ON
STATE OF UTAH AMENDEDREPORT FORM 8DEPARTMENT OF NATURAL RESOURCES (highlight changes)
D1VISION OF OIL, GAS AND MIN1NG 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF LNDIAN, ALLOTTEE OR TRIBE NAME
WELL COMPLETION OR RECOMPLETION REPORT AND LOG18. TYPE OF WELL: OW
LLWA
L DRY OTHan helium 7. UNITorCA AGREEMENT NAME
b. TYPE OF WORK: 8. WELL NAMEand NUMBER:NWEE HOR EP-
TRY RS . OTHER Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER
Flatirons Resources LLC 43019500293. ADDRESS OF DPERATOR: PHONE MUMBER: 10 FIELDANDPOOL, OR WILDCAT
11080 Circle Point Rd #6 Westminster - CO 80020 (303) 292-3902 Harley Dome4. LOCATIONOF WELL(FOOTAGES) 11. OTRIOTR, SECTION, TOWNSHIP, RANGE,
MERfDIAN:AT SURFACE: 1402' FNL 757' FEL SENE 4 19S 25EAT TOP PRODUCING IMTERVAL REPORTED BELOW: VOft|CS WO|
12. COUNTY 13. STATEAT TOTALDEPTH: VertÍCal WelÎ Grand UTAH
14. DATESPUDDED: 15. DATE T.D. REACHED: 16. DATE COMPLETED: 17. ELEVATIONS(DF, RKB, RT, GL).
8/6/2013 8/12/2013 8/14/2013 ABANDONED READYTO PRODUCE Z 4945 GL18. TOTALDEPTH: MD 965 19. PLUG BACKT.D : MD 20. IF MULTIPLECOMPLETIONS, HOW MANY7* 21. DEPTH BRIOGE MD
PLUGSET:TVD TVD TVO
22. TYPE ELECTRICANDOTHER MECHANICALLOGS RUN (Submit copyofeach) 23.
Array induction/Density/ Neutron/Gamma Ray WASWELLCORED? NO YES (Submitanalysis)
WAS DST RUN7 NO YES (Submit repod)
DIRECTIONALSURVEY? NO YES (Submitcopy)
24. CASINGAND LINERRECORD (Report all strings set In well)
HOLE S1ZE SIZEIGRADE WEIGHT (#lft.) TOP (MD) BOTTOM (MD)$TAGE CEMHENTER CNEME
SA S VOL M BBL} CEMENTTOP " AMOUNT PULLED
12 1/4 9 5/6 N-40 32.3 0 264 Class § 65 120 08 3/4 7 J-55 26 595 868 classg 81 506 868 965
25. TUBING RECORD
DEPTH SET (MD) PACKER SET (MD) SfZE DEPTH SET (MD) PACKER SET (MD) SIZE DEPTH SET (MD) PACKER SET (MD)
25. PRODUCING INTERVALS 27. PERFORATION RECORD
FORMATIONNAME TOP (MD} BOTTOM(MD) TOP (TVD) BOTTOM(TVD) INTERVAL(ToplBot - MD) SizE NO.HOLE$ PERFORATION STATU$
(A) Entrada 868 965 open Squeezed
(B) Open Squeezed
(C) Open Squeezed
(D) Open Squeezed
28. ACID,FRACTURE, TREATMENT,CEMENTSQLIEEZE,ETC.
WAS WELL HYORAULICALLYFRACTURED? YES NO IF YES - DATE FRACTURED:
OEPTH INTERVAL AMOUNTANDTYPEOF MATERIAL
29, ENCLO5ED ATTACHMENTS: 30. WELL STATUS:
ELECTRICAUMECHANICALLOGB GEOLOGIC REPORT DST REPORT DIRECTIONALSURVEY
O StJNDRY NOTICE FOR PLUGG1NGANDCEMENT VERIFLCATION CORE ANALYSIS DTHER:
(Sr2o13) (CONTINUED ON
STATE OF UTAH AMENDEDREPORT FORM 8DEPARTMENT OF NATURAL RESOURCES (highlight changes)
D1VISION OF OIL, GAS AND MIN1NG 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF LNDIAN, ALLOTTEE OR TRIBE NAME
WELL COMPLETION OR RECOMPLETION REPORT AND LOG18. TYPE OF WELL: OW
LLWA
L DRY OTHan helium 7. UNITorCA AGREEMENT NAME
b. TYPE OF WORK: 8. WELL NAMEand NUMBER:NWEE HOR EP-
TRY RS . OTHER Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER
Flatirons Resources LLC 43019500293. ADDRESS OF DPERATOR: PHONE MUMBER: 10 FIELDANDPOOL, OR WILDCAT
11080 Circle Point Rd #6 Westminster - CO 80020 (303) 292-3902 Harley Dome4. LOCATIONOF WELL(FOOTAGES) 11. OTRIOTR, SECTION, TOWNSHIP, RANGE,
MERfDIAN:AT SURFACE: 1402' FNL 757' FEL SENE 4 19S 25EAT TOP PRODUCING IMTERVAL REPORTED BELOW: VOft|CS WO|
12. COUNTY 13. STATEAT TOTALDEPTH: VertÍCal WelÎ Grand UTAH
14. DATESPUDDED: 15. DATE T.D. REACHED: 16. DATE COMPLETED: 17. ELEVATIONS(DF, RKB, RT, GL).
8/6/2013 8/12/2013 8/14/2013 ABANDONED READYTO PRODUCE Z 4945 GL18. TOTALDEPTH: MD 965 19. PLUG BACKT.D : MD 20. IF MULTIPLECOMPLETIONS, HOW MANY7* 21. DEPTH BRIOGE MD
PLUGSET:TVD TVD TVO
22. TYPE ELECTRICANDOTHER MECHANICALLOGS RUN (Submit copyofeach) 23.
Array induction/Density/ Neutron/Gamma Ray WASWELLCORED? NO YES (Submitanalysis)
WAS DST RUN7 NO YES (Submit repod)
DIRECTIONALSURVEY? NO YES (Submitcopy)
24. CASINGAND LINERRECORD (Report all strings set In well)
HOLE S1ZE SIZEIGRADE WEIGHT (#lft.) TOP (MD) BOTTOM (MD)$TAGE CEMHENTER CNEME
SA S VOL M BBL} CEMENTTOP " AMOUNT PULLED
12 1/4 9 5/6 N-40 32.3 0 264 Class § 65 120 08 3/4 7 J-55 26 595 868 classg 81 506 868 965
25. TUBING RECORD
DEPTH SET (MD) PACKER SET (MD) SfZE DEPTH SET (MD) PACKER SET (MD) SIZE DEPTH SET (MD) PACKER SET (MD)
25. PRODUCING INTERVALS 27. PERFORATION RECORD
FORMATIONNAME TOP (MD} BOTTOM(MD) TOP (TVD) BOTTOM(TVD) INTERVAL(ToplBot - MD) SizE NO.HOLE$ PERFORATION STATU$
(A) Entrada 868 965 open Squeezed
(B) Open Squeezed
(C) Open Squeezed
(D) Open Squeezed
28. ACID,FRACTURE, TREATMENT,CEMENTSQLIEEZE,ETC.
WAS WELL HYORAULICALLYFRACTURED? YES NO IF YES - DATE FRACTURED:
OEPTH INTERVAL AMOUNTANDTYPEOF MATERIAL
29, ENCLO5ED ATTACHMENTS: 30. WELL STATUS:
ELECTRICAUMECHANICALLOGB GEOLOGIC REPORT DST REPORT DIRECTIONALSURVEY
O StJNDRY NOTICE FOR PLUGG1NGANDCEMENT VERIFLCATION CORE ANALYSIS DTHER:
(Sr2o13) (CONTINUED ON
STATE OF UTAH AMENDEDREPORT FORM 8DEPARTMENT OF NATURAL RESOURCES (highlight changes)
D1VISION OF OIL, GAS AND MIN1NG 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF LNDIAN, ALLOTTEE OR TRIBE NAME
WELL COMPLETION OR RECOMPLETION REPORT AND LOG18. TYPE OF WELL: OW
LLWA
L DRY OTHan helium 7. UNITorCA AGREEMENT NAME
b. TYPE OF WORK: 8. WELL NAMEand NUMBER:NWEE HOR EP-
TRY RS . OTHER Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER
Flatirons Resources LLC 43019500293. ADDRESS OF DPERATOR: PHONE MUMBER: 10 FIELDANDPOOL, OR WILDCAT
11080 Circle Point Rd #6 Westminster - CO 80020 (303) 292-3902 Harley Dome4. LOCATIONOF WELL(FOOTAGES) 11. OTRIOTR, SECTION, TOWNSHIP, RANGE,
MERfDIAN:AT SURFACE: 1402' FNL 757' FEL SENE 4 19S 25EAT TOP PRODUCING IMTERVAL REPORTED BELOW: VOft|CS WO|
12. COUNTY 13. STATEAT TOTALDEPTH: VertÍCal WelÎ Grand UTAH
14. DATESPUDDED: 15. DATE T.D. REACHED: 16. DATE COMPLETED: 17. ELEVATIONS(DF, RKB, RT, GL).
8/6/2013 8/12/2013 8/14/2013 ABANDONED READYTO PRODUCE Z 4945 GL18. TOTALDEPTH: MD 965 19. PLUG BACKT.D : MD 20. IF MULTIPLECOMPLETIONS, HOW MANY7* 21. DEPTH BRIOGE MD
PLUGSET:TVD TVD TVO
22. TYPE ELECTRICANDOTHER MECHANICALLOGS RUN (Submit copyofeach) 23.
Array induction/Density/ Neutron/Gamma Ray WASWELLCORED? NO YES (Submitanalysis)
WAS DST RUN7 NO YES (Submit repod)
DIRECTIONALSURVEY? NO YES (Submitcopy)
24. CASINGAND LINERRECORD (Report all strings set In well)
HOLE S1ZE SIZEIGRADE WEIGHT (#lft.) TOP (MD) BOTTOM (MD)$TAGE CEMHENTER CNEME
SA S VOL M BBL} CEMENTTOP " AMOUNT PULLED
12 1/4 9 5/6 N-40 32.3 0 264 Class § 65 120 08 3/4 7 J-55 26 595 868 classg 81 506 868 965
25. TUBING RECORD
DEPTH SET (MD) PACKER SET (MD) SfZE DEPTH SET (MD) PACKER SET (MD) SIZE DEPTH SET (MD) PACKER SET (MD)
25. PRODUCING INTERVALS 27. PERFORATION RECORD
FORMATIONNAME TOP (MD} BOTTOM(MD) TOP (TVD) BOTTOM(TVD) INTERVAL(ToplBot - MD) SizE NO.HOLE$ PERFORATION STATU$
(A) Entrada 868 965 open Squeezed
(B) Open Squeezed
(C) Open Squeezed
(D) Open Squeezed
28. ACID,FRACTURE, TREATMENT,CEMENTSQLIEEZE,ETC.
WAS WELL HYORAULICALLYFRACTURED? YES NO IF YES - DATE FRACTURED:
OEPTH INTERVAL AMOUNTANDTYPEOF MATERIAL
29, ENCLO5ED ATTACHMENTS: 30. WELL STATUS:
ELECTRICAUMECHANICALLOGB GEOLOGIC REPORT DST REPORT DIRECTIONALSURVEY
O StJNDRY NOTICE FOR PLUGG1NGANDCEMENT VERIFLCATION CORE ANALYSIS DTHER:
(Sr2o13) (CONTINUED ON
STATE OF UTAH AMENDEDREPORT FORM 8DEPARTMENT OF NATURAL RESOURCES (highlight changes)
D1VISION OF OIL, GAS AND MIN1NG 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF LNDIAN, ALLOTTEE OR TRIBE NAME
WELL COMPLETION OR RECOMPLETION REPORT AND LOG18. TYPE OF WELL: OW
LLWA
L DRY OTHan helium 7. UNITorCA AGREEMENT NAME
b. TYPE OF WORK: 8. WELL NAMEand NUMBER:NWEE HOR EP-
TRY RS . OTHER Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER
Flatirons Resources LLC 43019500293. ADDRESS OF DPERATOR: PHONE MUMBER: 10 FIELDANDPOOL, OR WILDCAT
11080 Circle Point Rd #6 Westminster - CO 80020 (303) 292-3902 Harley Dome4. LOCATIONOF WELL(FOOTAGES) 11. OTRIOTR, SECTION, TOWNSHIP, RANGE,
MERfDIAN:AT SURFACE: 1402' FNL 757' FEL SENE 4 19S 25EAT TOP PRODUCING IMTERVAL REPORTED BELOW: VOft|CS WO|
12. COUNTY 13. STATEAT TOTALDEPTH: VertÍCal WelÎ Grand UTAH
14. DATESPUDDED: 15. DATE T.D. REACHED: 16. DATE COMPLETED: 17. ELEVATIONS(DF, RKB, RT, GL).
8/6/2013 8/12/2013 8/14/2013 ABANDONED READYTO PRODUCE Z 4945 GL18. TOTALDEPTH: MD 965 19. PLUG BACKT.D : MD 20. IF MULTIPLECOMPLETIONS, HOW MANY7* 21. DEPTH BRIOGE MD
PLUGSET:TVD TVD TVO
22. TYPE ELECTRICANDOTHER MECHANICALLOGS RUN (Submit copyofeach) 23.
Array induction/Density/ Neutron/Gamma Ray WASWELLCORED? NO YES (Submitanalysis)
WAS DST RUN7 NO YES (Submit repod)
DIRECTIONALSURVEY? NO YES (Submitcopy)
24. CASINGAND LINERRECORD (Report all strings set In well)
HOLE S1ZE SIZEIGRADE WEIGHT (#lft.) TOP (MD) BOTTOM (MD)$TAGE CEMHENTER CNEME
SA S VOL M BBL} CEMENTTOP " AMOUNT PULLED
12 1/4 9 5/6 N-40 32.3 0 264 Class § 65 120 08 3/4 7 J-55 26 595 868 classg 81 506 868 965
25. TUBING RECORD
DEPTH SET (MD) PACKER SET (MD) SfZE DEPTH SET (MD) PACKER SET (MD) SIZE DEPTH SET (MD) PACKER SET (MD)
25. PRODUCING INTERVALS 27. PERFORATION RECORD
FORMATIONNAME TOP (MD} BOTTOM(MD) TOP (TVD) BOTTOM(TVD) INTERVAL(ToplBot - MD) SizE NO.HOLE$ PERFORATION STATU$
(A) Entrada 868 965 open Squeezed
(B) Open Squeezed
(C) Open Squeezed
(D) Open Squeezed
28. ACID,FRACTURE, TREATMENT,CEMENTSQLIEEZE,ETC.
WAS WELL HYORAULICALLYFRACTURED? YES NO IF YES - DATE FRACTURED:
OEPTH INTERVAL AMOUNTANDTYPEOF MATERIAL
29, ENCLO5ED ATTACHMENTS: 30. WELL STATUS:
ELECTRICAUMECHANICALLOGB GEOLOGIC REPORT DST REPORT DIRECTIONALSURVEY
O StJNDRY NOTICE FOR PLUGG1NGANDCEMENT VERIFLCATION CORE ANALYSIS DTHER:
(Sr2o13) (CONTINUED ON
STATE OF UTAH AMENDEDREPORT FORM 8DEPARTMENT OF NATURAL RESOURCES (highlight changes)
D1VISION OF OIL, GAS AND MIN1NG 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF LNDIAN, ALLOTTEE OR TRIBE NAME
WELL COMPLETION OR RECOMPLETION REPORT AND LOG18. TYPE OF WELL: OW
LLWA
L DRY OTHan helium 7. UNITorCA AGREEMENT NAME
b. TYPE OF WORK: 8. WELL NAMEand NUMBER:NWEE HOR EP-
TRY RS . OTHER Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER
Flatirons Resources LLC 43019500293. ADDRESS OF DPERATOR: PHONE MUMBER: 10 FIELDANDPOOL, OR WILDCAT
11080 Circle Point Rd #6 Westminster - CO 80020 (303) 292-3902 Harley Dome4. LOCATIONOF WELL(FOOTAGES) 11. OTRIOTR, SECTION, TOWNSHIP, RANGE,
MERfDIAN:AT SURFACE: 1402' FNL 757' FEL SENE 4 19S 25EAT TOP PRODUCING IMTERVAL REPORTED BELOW: VOft|CS WO|
12. COUNTY 13. STATEAT TOTALDEPTH: VertÍCal WelÎ Grand UTAH
14. DATESPUDDED: 15. DATE T.D. REACHED: 16. DATE COMPLETED: 17. ELEVATIONS(DF, RKB, RT, GL).
8/6/2013 8/12/2013 8/14/2013 ABANDONED READYTO PRODUCE Z 4945 GL18. TOTALDEPTH: MD 965 19. PLUG BACKT.D : MD 20. IF MULTIPLECOMPLETIONS, HOW MANY7* 21. DEPTH BRIOGE MD
PLUGSET:TVD TVD TVO
22. TYPE ELECTRICANDOTHER MECHANICALLOGS RUN (Submit copyofeach) 23.
Array induction/Density/ Neutron/Gamma Ray WASWELLCORED? NO YES (Submitanalysis)
WAS DST RUN7 NO YES (Submit repod)
DIRECTIONALSURVEY? NO YES (Submitcopy)
24. CASINGAND LINERRECORD (Report all strings set In well)
HOLE S1ZE SIZEIGRADE WEIGHT (#lft.) TOP (MD) BOTTOM (MD)$TAGE CEMHENTER CNEME
SA S VOL M BBL} CEMENTTOP " AMOUNT PULLED
12 1/4 9 5/6 N-40 32.3 0 264 Class § 65 120 08 3/4 7 J-55 26 595 868 classg 81 506 868 965
25. TUBING RECORD
DEPTH SET (MD) PACKER SET (MD) SfZE DEPTH SET (MD) PACKER SET (MD) SIZE DEPTH SET (MD) PACKER SET (MD)
25. PRODUCING INTERVALS 27. PERFORATION RECORD
FORMATIONNAME TOP (MD} BOTTOM(MD) TOP (TVD) BOTTOM(TVD) INTERVAL(ToplBot - MD) SizE NO.HOLE$ PERFORATION STATU$
(A) Entrada 868 965 open Squeezed
(B) Open Squeezed
(C) Open Squeezed
(D) Open Squeezed
28. ACID,FRACTURE, TREATMENT,CEMENTSQLIEEZE,ETC.
WAS WELL HYORAULICALLYFRACTURED? YES NO IF YES - DATE FRACTURED:
OEPTH INTERVAL AMOUNTANDTYPEOF MATERIAL
29, ENCLO5ED ATTACHMENTS: 30. WELL STATUS:
ELECTRICAUMECHANICALLOGB GEOLOGIC REPORT DST REPORT DIRECTIONALSURVEY
O StJNDRY NOTICE FOR PLUGG1NGANDCEMENT VERIFLCATION CORE ANALYSIS DTHER:
(Sr2o13) (CONTINUED ON
STATE OF UTAH AMENDEDREPORT FORM 8DEPARTMENT OF NATURAL RESOURCES (highlight changes)
D1VISION OF OIL, GAS AND MIN1NG 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF LNDIAN, ALLOTTEE OR TRIBE NAME
WELL COMPLETION OR RECOMPLETION REPORT AND LOG18. TYPE OF WELL: OW
LLWA
L DRY OTHan helium 7. UNITorCA AGREEMENT NAME
b. TYPE OF WORK: 8. WELL NAMEand NUMBER:NWEE HOR EP-
TRY RS . OTHER Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER
Flatirons Resources LLC 43019500293. ADDRESS OF DPERATOR: PHONE MUMBER: 10 FIELDANDPOOL, OR WILDCAT
11080 Circle Point Rd #6 Westminster - CO 80020 (303) 292-3902 Harley Dome4. LOCATIONOF WELL(FOOTAGES) 11. OTRIOTR, SECTION, TOWNSHIP, RANGE,
MERfDIAN:AT SURFACE: 1402' FNL 757' FEL SENE 4 19S 25EAT TOP PRODUCING IMTERVAL REPORTED BELOW: VOft|CS WO|
12. COUNTY 13. STATEAT TOTALDEPTH: VertÍCal WelÎ Grand UTAH
14. DATESPUDDED: 15. DATE T.D. REACHED: 16. DATE COMPLETED: 17. ELEVATIONS(DF, RKB, RT, GL).
8/6/2013 8/12/2013 8/14/2013 ABANDONED READYTO PRODUCE Z 4945 GL18. TOTALDEPTH: MD 965 19. PLUG BACKT.D : MD 20. IF MULTIPLECOMPLETIONS, HOW MANY7* 21. DEPTH BRIOGE MD
PLUGSET:TVD TVD TVO
22. TYPE ELECTRICANDOTHER MECHANICALLOGS RUN (Submit copyofeach) 23.
Array induction/Density/ Neutron/Gamma Ray WASWELLCORED? NO YES (Submitanalysis)
WAS DST RUN7 NO YES (Submit repod)
DIRECTIONALSURVEY? NO YES (Submitcopy)
24. CASINGAND LINERRECORD (Report all strings set In well)
HOLE S1ZE SIZEIGRADE WEIGHT (#lft.) TOP (MD) BOTTOM (MD)$TAGE CEMHENTER CNEME
SA S VOL M BBL} CEMENTTOP " AMOUNT PULLED
12 1/4 9 5/6 N-40 32.3 0 264 Class § 65 120 08 3/4 7 J-55 26 595 868 classg 81 506 868 965
25. TUBING RECORD
DEPTH SET (MD) PACKER SET (MD) SfZE DEPTH SET (MD) PACKER SET (MD) SIZE DEPTH SET (MD) PACKER SET (MD)
25. PRODUCING INTERVALS 27. PERFORATION RECORD
FORMATIONNAME TOP (MD} BOTTOM(MD) TOP (TVD) BOTTOM(TVD) INTERVAL(ToplBot - MD) SizE NO.HOLE$ PERFORATION STATU$
(A) Entrada 868 965 open Squeezed
(B) Open Squeezed
(C) Open Squeezed
(D) Open Squeezed
28. ACID,FRACTURE, TREATMENT,CEMENTSQLIEEZE,ETC.
WAS WELL HYORAULICALLYFRACTURED? YES NO IF YES - DATE FRACTURED:
OEPTH INTERVAL AMOUNTANDTYPEOF MATERIAL
29, ENCLO5ED ATTACHMENTS: 30. WELL STATUS:
ELECTRICAUMECHANICALLOGB GEOLOGIC REPORT DST REPORT DIRECTIONALSURVEY
O StJNDRY NOTICE FOR PLUGG1NGANDCEMENT VERIFLCATION CORE ANALYSIS DTHER:
(Sr2o13) (CONTINUED ON
STATE OF UTAH AMENDEDREPORT FORM 8DEPARTMENT OF NATURAL RESOURCES (highlight changes)
D1VISION OF OIL, GAS AND MIN1NG 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF LNDIAN, ALLOTTEE OR TRIBE NAME
WELL COMPLETION OR RECOMPLETION REPORT AND LOG18. TYPE OF WELL: OW
LLWA
L DRY OTHan helium 7. UNITorCA AGREEMENT NAME
b. TYPE OF WORK: 8. WELL NAMEand NUMBER:NWEE HOR EP-
TRY RS . OTHER Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER
Flatirons Resources LLC 43019500293. ADDRESS OF DPERATOR: PHONE MUMBER: 10 FIELDANDPOOL, OR WILDCAT
11080 Circle Point Rd #6 Westminster - CO 80020 (303) 292-3902 Harley Dome4. LOCATIONOF WELL(FOOTAGES) 11. OTRIOTR, SECTION, TOWNSHIP, RANGE,
MERfDIAN:AT SURFACE: 1402' FNL 757' FEL SENE 4 19S 25EAT TOP PRODUCING IMTERVAL REPORTED BELOW: VOft|CS WO|
12. COUNTY 13. STATEAT TOTALDEPTH: VertÍCal WelÎ Grand UTAH
14. DATESPUDDED: 15. DATE T.D. REACHED: 16. DATE COMPLETED: 17. ELEVATIONS(DF, RKB, RT, GL).
8/6/2013 8/12/2013 8/14/2013 ABANDONED READYTO PRODUCE Z 4945 GL18. TOTALDEPTH: MD 965 19. PLUG BACKT.D : MD 20. IF MULTIPLECOMPLETIONS, HOW MANY7* 21. DEPTH BRIOGE MD
PLUGSET:TVD TVD TVO
22. TYPE ELECTRICANDOTHER MECHANICALLOGS RUN (Submit copyofeach) 23.
Array induction/Density/ Neutron/Gamma Ray WASWELLCORED? NO YES (Submitanalysis)
WAS DST RUN7 NO YES (Submit repod)
DIRECTIONALSURVEY? NO YES (Submitcopy)
24. CASINGAND LINERRECORD (Report all strings set In well)
HOLE S1ZE SIZEIGRADE WEIGHT (#lft.) TOP (MD) BOTTOM (MD)$TAGE CEMHENTER CNEME
SA S VOL M BBL} CEMENTTOP " AMOUNT PULLED
12 1/4 9 5/6 N-40 32.3 0 264 Class § 65 120 08 3/4 7 J-55 26 595 868 classg 81 506 868 965
25. TUBING RECORD
DEPTH SET (MD) PACKER SET (MD) SfZE DEPTH SET (MD) PACKER SET (MD) SIZE DEPTH SET (MD) PACKER SET (MD)
25. PRODUCING INTERVALS 27. PERFORATION RECORD
FORMATIONNAME TOP (MD} BOTTOM(MD) TOP (TVD) BOTTOM(TVD) INTERVAL(ToplBot - MD) SizE NO.HOLE$ PERFORATION STATU$
(A) Entrada 868 965 open Squeezed
(B) Open Squeezed
(C) Open Squeezed
(D) Open Squeezed
28. ACID,FRACTURE, TREATMENT,CEMENTSQLIEEZE,ETC.
WAS WELL HYORAULICALLYFRACTURED? YES NO IF YES - DATE FRACTURED:
OEPTH INTERVAL AMOUNTANDTYPEOF MATERIAL
29, ENCLO5ED ATTACHMENTS: 30. WELL STATUS:
ELECTRICAUMECHANICALLOGB GEOLOGIC REPORT DST REPORT DIRECTIONALSURVEY
O StJNDRY NOTICE FOR PLUGG1NGANDCEMENT VERIFLCATION CORE ANALYSIS DTHER:
(Sr2o13) (CONTINUED ON
STATE OF UTAH AMENDEDREPORT FORM 8DEPARTMENT OF NATURAL RESOURCES (highlight changes)
D1VISION OF OIL, GAS AND MIN1NG 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF LNDIAN, ALLOTTEE OR TRIBE NAME
WELL COMPLETION OR RECOMPLETION REPORT AND LOG18. TYPE OF WELL: OW
LLWA
L DRY OTHan helium 7. UNITorCA AGREEMENT NAME
b. TYPE OF WORK: 8. WELL NAMEand NUMBER:NWEE HOR EP-
TRY RS . OTHER Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER
Flatirons Resources LLC 43019500293. ADDRESS OF DPERATOR: PHONE MUMBER: 10 FIELDANDPOOL, OR WILDCAT
11080 Circle Point Rd #6 Westminster - CO 80020 (303) 292-3902 Harley Dome4. LOCATIONOF WELL(FOOTAGES) 11. OTRIOTR, SECTION, TOWNSHIP, RANGE,
MERfDIAN:AT SURFACE: 1402' FNL 757' FEL SENE 4 19S 25EAT TOP PRODUCING IMTERVAL REPORTED BELOW: VOft|CS WO|
12. COUNTY 13. STATEAT TOTALDEPTH: VertÍCal WelÎ Grand UTAH
14. DATESPUDDED: 15. DATE T.D. REACHED: 16. DATE COMPLETED: 17. ELEVATIONS(DF, RKB, RT, GL).
8/6/2013 8/12/2013 8/14/2013 ABANDONED READYTO PRODUCE Z 4945 GL18. TOTALDEPTH: MD 965 19. PLUG BACKT.D : MD 20. IF MULTIPLECOMPLETIONS, HOW MANY7* 21. DEPTH BRIOGE MD
PLUGSET:TVD TVD TVO
22. TYPE ELECTRICANDOTHER MECHANICALLOGS RUN (Submit copyofeach) 23.
Array induction/Density/ Neutron/Gamma Ray WASWELLCORED? NO YES (Submitanalysis)
WAS DST RUN7 NO YES (Submit repod)
DIRECTIONALSURVEY? NO YES (Submitcopy)
24. CASINGAND LINERRECORD (Report all strings set In well)
HOLE S1ZE SIZEIGRADE WEIGHT (#lft.) TOP (MD) BOTTOM (MD)$TAGE CEMHENTER CNEME
SA S VOL M BBL} CEMENTTOP " AMOUNT PULLED
12 1/4 9 5/6 N-40 32.3 0 264 Class § 65 120 08 3/4 7 J-55 26 595 868 classg 81 506 868 965
25. TUBING RECORD
DEPTH SET (MD) PACKER SET (MD) SfZE DEPTH SET (MD) PACKER SET (MD) SIZE DEPTH SET (MD) PACKER SET (MD)
25. PRODUCING INTERVALS 27. PERFORATION RECORD
FORMATIONNAME TOP (MD} BOTTOM(MD) TOP (TVD) BOTTOM(TVD) INTERVAL(ToplBot - MD) SizE NO.HOLE$ PERFORATION STATU$
(A) Entrada 868 965 open Squeezed
(B) Open Squeezed
(C) Open Squeezed
(D) Open Squeezed
28. ACID, FRACTURE, TREATMENT, CEMENT SQLIEEZE, ETC.
WAS WELL HYORAULICALLY FRACTURED? YES NO IF YES - DATE FRACTURED:
DEPTH INTERVAL AMOLINTANDTYPEOF MATERIAL
29. ENCLOSED ATTACHMENTS: 30. WELL STATUS:
ELECTRICAUMECHANICAL LOGB GEOLOGIC REPORT DST REPORT DIRECTIONALSURVEY
O StJNDRY NOTICE FOR PLUGG1NGANDCEMENT VERIFLCATION CORE ANALYSIS DTHER:
(Sr2o13) (CONTINUED ON
STATE OF UTAH AMENDEDREPORT FORM 8DEPARTMENT OF NATURAL RESOURCES (highlight changes)
D1VISION OF OIL, GAS AND MIN1NG 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF LNDIAN, ALLOTTEE OR TRIBE NAME
WELL COMPLETION OR RECOMPLETION REPORT AND LOG18. TYPE OF WELL: OW
LLWA
L DRY OTHan helium 7. UNITorCA AGREEMENT NAME
b. TYPE OF WORK: 8. WELL NAMEand NUMBER:NWEE HOR EP-
TRY RS . OTHER Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER
Flatirons Resources LLC 43019500293. ADDRESS OF DPERATOR: PHONE MUMBER: 10 FIELDANDPOOL, OR WILDCAT
11080 Circle Point Rd #6 Westminster - CO 80020 (303) 292-3902 Harley Dome4. LOCATIONOF WELL(FOOTAGES) 11. OTRIOTR, SECTION, TOWNSHIP, RANGE,
MERfDIAN:AT SURFACE: 1402' FNL 757' FEL SENE 4 19S 25EAT TOP PRODUCING IMTERVAL REPORTED BELOW: VOft|CS WO|
12. COUNTY 13. STATEAT TOTALDEPTH: VertÍCal WelÎ Grand UTAH
14. DATESPUDDED: 15. DATE T.D. REACHED: 16. DATE COMPLETED: 17. ELEVATIONS(DF, RKB, RT, GL).
8/6/2013 8/12/2013 8/14/2013 ABANDONED READYTO PRODUCE Z 4945 GL18. TOTALDEPTH: MD 965 19. PLUG BACKT.D : MD 20. IF MULTIPLECOMPLETIONS, HOW MANY7* 21. DEPTH BRIOGE MD
PLUGSET:TVD TVD TVO
22. TYPE ELECTRICANDOTHER MECHANICALLOGS RUN (Submit copyofeach) 23.
Array induction/Density/ Neutron/Gamma Ray WASWELLCORED? NO YES (Submitanalysis)
WAS DST RUN7 NO YES (Submit repod)
DIRECTIONALSURVEY? NO YES (Submitcopy)
24. CASINGAND LINERRECORD (Report all strings set In well)
HOLE S1ZE SIZEIGRADE WEIGHT (#lft.) TOP (MD) BOTTOM (MD)$TAGE CEMHENTER CNEME
SA S VOL M BBL} CEMENTTOP " AMOUNT PULLED
12 1/4 9 5/6 N-40 32.3 0 264 Class § 65 120 08 3/4 7 J-55 26 595 868 classg 81 506 868 965
25. TUBING RECORD
DEPTH SET (MD) PACKER SET (MD) SfZE DEPTH SET (MD) PACKER SET (MD) SIZE DEPTH SET (MD) PACKER SET (MD)
25. PRODUCING INTERVALS 27. PERFORATION RECORD
FORMATIONNAME TOP (MD} BOTTOM(MD) TOP (TVD) BOTTOM(TVD) INTERVAL(ToplBot - MD) SizE NO.HOLE$ PERFORATION STATU$
(A) Entrada 868 965 open Squeezed
(B) Open Squeezed
(C) Open Squeezed
(D) Open Squeezed
28. ACID, FRACTURE, TREATMENT, CEMENT SQLIEEZE, ETC.
WAS WELL HYORAULICALLY FRACTURED? YES NO IF YES - DATE FRACTURED:
DEPTH INTERVAL AMOLINTANDTYPEOF MATERIAL
29. ENCLOSED ATTACHMENTS: 30. WELL STATUS:
ELECTRICAUMECHANICAL LOGB GEOLOGIC REPORT DST REPORT DIRECTIONALSURVEY
O StJNDRY NOTICE FOR PLUGG1NGANDCEMENT VERIFLCATION CORE ANALYSIS DTHER:
(Sr2o13) (CONTINUED ON
STATE OF UTAH AMENDEDREPORT FORM 8DEPARTMENT OF NATURAL RESOURCES (highlight changes)
D1VISION OF OIL, GAS AND MIN1NG 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF LNDIAN, ALLOTTEE OR TRIBE NAME
WELL COMPLETION OR RECOMPLETION REPORT AND LOG18. TYPE OF WELL: OW
LLWA
L DRY OTHan helium 7. UNITorCA AGREEMENT NAME
b. TYPE OF WORK: 8. WELL NAMEand NUMBER:NWEE HOR EP-
TRY RS . OTHER Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER
Flatirons Resources LLC 43019500293. ADDRESS OF DPERATOR: PHONE MUMBER: 10 FIELDANDPOOL, OR WILDCAT
11080 Circle Point Rd #6 Westminster - CO 80020 (303) 292-3902 Harley Dome4. LOCATIONOF WELL(FOOTAGES) 11. OTRIOTR, SECTION, TOWNSHIP, RANGE,
MERfDIAN:AT SURFACE: 1402' FNL 757' FEL SENE 4 19S 25EAT TOP PRODUCING IMTERVAL REPORTED BELOW: VOft|CS WO|
12. COUNTY 13. STATEAT TOTALDEPTH: VertÍCal WelÎ Grand UTAH
14. DATESPUDDED: 15. DATE T.D. REACHED: 16. DATE COMPLETED: 17. ELEVATIONS(DF, RKB, RT, GL).
8/6/2013 8/12/2013 8/14/2013 ABANDONED READYTO PRODUCE Z 4945 GL18. TOTALDEPTH: MD 965 19. PLUG BACKT.D : MD 20. IF MULTIPLECOMPLETIONS, HOW MANY7* 21. DEPTH BRIOGE MD
PLUGSET:TVD TVD TVO
22. TYPE ELECTRICANDOTHER MECHANICALLOGS RUN (Submit copyofeach) 23.
Array induction/Density/ Neutron/Gamma Ray WASWELLCORED? NO YES (Submitanalysis)
WAS DST RUN7 NO YES (Submit repod)
DIRECTIONALSURVEY? NO YES (Submitcopy)
24. CASINGAND LINERRECORD (Report all strings set In well)
HOLE S1ZE SIZEIGRADE WEIGHT (#lft.) TOP (MD) BOTTOM (MD)$TAGE CEMHENTER CNEME
SA S VOL M BBL} CEMENTTOP " AMOUNT PULLED
12 1/4 9 5/6 N-40 32.3 0 264 Class § 65 120 08 3/4 7 J-55 26 595 868 classg 81 506 868 965
25. TUBING RECORD
DEPTH SET (MD) PACKER SET (MD) SfZE DEPTH SET (MD) PACKER SET (MD) SIZE DEPTH SET (MD) PACKER SET (MD)
25. PRODUCING INTERVALS 27. PERFORATION RECORD
FORMATIONNAME TOP (MD} BOTTOM(MD) TOP (TVD) BOTTOM(TVD) INTERVAL(ToplBot - MD) SizE NO.HOLE$ PERFORATION STATU$
(A) Entrada 868 965 open Squeezed
(B) Open Squeezed
(C) Open Squeezed
(D) Open Squeezed
28. ACID, FRACTURE, TREATMENT, CEMENT SQLIEEZE, ETC.
WAS WELL HYORAULICALLY FRACTURED? YES NO IF YES - DATE FRACTURED:
DEPTH INTERVAL AMOLINTANDTYPEOF MATERIAL
29. ENCLOSED ATTACHMENTS: 30. WELL STATUS:
ELECTRICAUMECHANICAL LOGB GEOLOGIC REPORT DST REPORT DIRECTIONALSURVEY
O StJNDRY NOTICE FOR PLUGG1NGANDCEMENT VERIFLCATION CORE ANALYSIS DTHER:
(Sr2o13) (CONTINUED ON
RECEIVED: Sep. 05, 2013
API Well Number: 43019500290000
31. INITIAL PRODUCTION INTERVALA {As shown in item #26}
DATEFIRST PRODUCED TEST DATE HOURS TESTED TEST PRODUCTION DIL - BBL GAS - MCF: WATER - BBL PROD. METHOD
8/12/2013 8/14/2013 3 RATES 0 245 0 ventedCHOKE SIZE TBG PRESS. CSG. PRESS. API GRAVITY BTU- GAS GASIOILRATIO 24 HR PRODUCTION DIL - BBL: GAS - MCF WATER- BBL INTERVALSTATUS
129 RATES O 1,964 0 SI w.o. gasa
INTERYALB (As shawn In liem #26)
DATEFIRST PRODUCED TEST DATE HOURS TESTEO: TEST PRODUCTION OIL - BBI GAS - MGF; WATER - BBL: PROD METHODRATES: -+
CHOKE SIZE: TBG. PRESS. CSG. PRESS, PI GRAVITY BTU - GAS GAS/OIL RATIO 24 HR PRODUCTION DIL- BBL: GAS - MCF: WATER - BBL: INTERVALSTATUSRATES: *
INTERVAL C (As shown In Item?26)
DATE FIRST PRODUCED TEST DATE; HOURS TESTED: TEST PRODUCTION OIL - BEIL: GAS - MCF: WATER -- BBL: PROD. METHODRATES: -+
CHOKESIZE TBG. PRESS. CSG. PRES5. PI GRAVITY BTU- GAS GAS/OILRATIO 24 HR PRODUCTION OIL - BEL: GAS - MCF: WATER - BBL: INTERVAL STATUSRATES; *
INTERVALD (As shown in Item #26)
DATE FIRST PRODUCED TEST DATE: MOURSTESTED: TEST PRODUCTION OIL- BBL: GAS- MCF: WATER - BBL: PROD. METHOD.RATES:
CHOKE SIZE TBG. PRESS. CSG. PRESS. PI GRAVITY BTU- GAS GASIOIL RATIO 24 HR PRODUCTlON OIL- BBL: GAS - MDF: WATER - BBL: INTERVALSTATUSRATES: -+
32. DISPDSITION OF GAS {Sold, Used for Fuel, Vented, Etc.)
vented walting on gas connection33, SUMMARYOF POROUS zONES(Inc1ude Aquifers): 34. FORMATION(Log) MARKERS;
Shaw all important zones ofporosity andcontentsthereof Cored intervals and all drill-stem lests, includingdepth interval tested,cushion used, timetuoiopen, ilowing and shut·in pressures and recoveries.
Formation a o Descriptions, Contents, etc Name (MeasuodpDepth)
Dakota 0 140 sandstone fine grain occasional dark miMorrison 140 868 poorly sorted varigated red, green anchEntrada 868 sandstone fine grain light gray
35. ADDITIONA1.REMARKS {Include plugging procedure)
Morrison Formation 577-580 Flow tested while drilling:1st flow 1.18 MCFD for 15 min @25.5 PSIA 1st SI 15 min built to 88 PSIA
-36. I hereby certlfy that thefaragaing and attached information is complete and correct as determined from allavailablerecords.
NAME PULEASEPR J EV vir s Managing Director
This repo ust ubmi within days of• co g a well e reentering a previously plugged and abandoned welle drillinghorizontal lat m an existing well bare • significantlydeepening an existing well bore below the previous bottom-hole deptha recompleting to a different producing formation • drilling hydrocarbon exploratory holes, such as core samples and stratigraphic tests
* ITEM 20: Show the number of completions if productlon is measured separately from twoor more formations.
** ITEM24: Cement Top - Show how reported top(s)ofcement were determined (circulated (CIR), calculated (CAL}, cement bond log (CBL). temperaturesurvey (TS)).
Send to: Utah Division of Oil, Gas and Minlng Phone 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City. Utah 84114-5801
31. INITIAL PRODUCTION INTERVALA {As shown in item #26}
DATEFIRST PRODUCED TEST DATE HOURS TESTED TEST PRODUCTION DIL - BBL GAS - MCF: WATER - BBL PROD. METHOD
8/12/2013 8/14/2013 3 RATES 0 245 0 ventedCHOKE SIZE TBG PRESS. CSG. PRESS. API GRAVITY BTU- GAS GASIOILRATIO 24 HR PRODUCTION DIL - BBL: GAS - MCF WATER- BBL INTERVALSTATUS
129 RATES O 1,964 0 SI w.o. gasa
INTERYALB (As shawn In liem #26)
DATEFIRST PRODUCED TEST DATE HOURS TESTEO: TEST PRODUCTION OIL - BBI GAS - MGF; WATER - BBL: PROD METHODRATES: -+
CHOKE SIZE: TBG. PRESS. CSG. PRESS, PI GRAVITY BTU - GAS GAS/OIL RATIO 24 HR PRODUCTION DIL- BBL: GAS - MCF: WATER - BBL: INTERVALSTATUSRATES: *
INTERVAL C (As shown In Item?26)
DATE FIRST PRODUCED TEST DATE; HOURS TESTED: TEST PRODUCTION OIL - BEIL: GAS - MCF: WATER -- BBL: PROD. METHODRATES: -+
CHOKESIZE TBG. PRESS. CSG. PRES5. PI GRAVITY BTU- GAS GAS/OILRATIO 24 HR PRODUCTION OIL - BEL: GAS - MCF: WATER - BBL: INTERVAL STATUSRATES; *
INTERVALD (As shown in Item #26)
DATE FIRST PRODUCED TEST DATE: MOURSTESTED: TEST PRODUCTION OIL- BBL: GAS- MCF: WATER - BBL: PROD. METHOD.RATES:
CHOKE SIZE TBG. PRESS. CSG. PRESS. PI GRAVITY BTU- GAS GASIOIL RATIO 24 HR PRODUCTlON OIL- BBL: GAS - MDF: WATER - BBL: INTERVALSTATUSRATES: -+
32. DISPDSITION OF GAS {Sold, Used for Fuel, Vented, Etc.)
vented walting on gas connection33, SUMMARYOF POROUS zONES(Inc1ude Aquifers): 34. FORMATION(Log) MARKERS;
Shaw all important zones ofporosity andcontentsthereof Cored intervals and all drill-stem lests, includingdepth interval tested,cushion used, timetuoiopen, ilowing and shut·in pressures and recoveries.
Formation a o Descriptions, Contents, etc Name (MeasuodpDepth)
Dakota 0 140 sandstone fine grain occasional dark miMorrison 140 868 poorly sorted varigated red, green anchEntrada 868 sandstone fine grain light gray
35. ADDITIONA1.REMARKS {Include plugging procedure)
Morrison Formation 577-580 Flow tested while drilling:1st flow 1.18 MCFD for 15 min @25.5 PSIA 1st SI 15 min built to 88 PSIA
-36. I hereby certlfy that thefaragaing and attached information is complete and correct as determined from allavailablerecords.
NAME PULEASEPR J EV vir s Managing Director
This repo ust ubmi within days of• co g a well e reentering a previously plugged and abandoned welle drillinghorizontal lat m an existing well bare • significantlydeepening an existing well bore below the previous bottom-hole deptha recompleting to a different producing formation • drilling hydrocarbon exploratory holes, such as core samples and stratigraphic tests
* ITEM 20: Show the number of completions if productlon is measured separately from twoor more formations.
** ITEM24: Cement Top - Show how reported top(s)ofcement were determined (circulated (CIR), calculated (CAL}, cement bond log (CBL). temperaturesurvey (TS)).
Send to: Utah Division of Oil, Gas and Minlng Phone 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City. Utah 84114-5801
31. INITIAL PRODUCTION INTERVALA {As shown in item #26}
DATEFIRST PRODUCED TEST DATE HOURS TESTED TEST PRODUCTION DIL - BBL GAS - MCF: WATER - BBL PROD. METHOD
8/12/2013 8/14/2013 3 RATES 0 245 0 ventedCHOKE SIZE TBG PRESS. CSG. PRESS. API GRAVITY BTU- GAS GASIOILRATIO 24 HR PRODUCTION DIL - BBL: GAS - MCF WATER- BBL INTERVALSTATUS
129 RATES O 1,964 0 SI w.o. gasa
INTERYALB (As shawn In liem #26)
DATEFIRST PRODUCED TEST DATE HOURS TESTEO: TEST PRODUCTION OIL - BBI GAS - MGF; WATER - BBL: PROD METHODRATES: -+
CHOKE SIZE: TBG. PRESS. CSG. PRESS, PI GRAVITY BTU - GAS GAS/OIL RATIO 24 HR PRODUCTION DIL- BBL: GAS - MCF: WATER - BBL: INTERVALSTATUSRATES: *
INTERVAL C (As shown In Item?26)
DATE FIRST PRODUCED TEST DATE; HOURS TESTED: TEST PRODUCTION OIL - BEIL: GAS - MCF: WATER -- BBL: PROD. METHODRATES: -+
CHOKESIZE TBG. PRESS. CSG. PRES5. PI GRAVITY BTU- GAS GAS/OILRATIO 24 HR PRODUCTION OIL - BEL: GAS - MCF: WATER - BBL: INTERVAL STATUSRATES; *
INTERVALD (As shown in Item #26)
DATE FIRST PRODUCED TEST DATE: MOURSTESTED: TEST PRODUCTION OIL- BBL: GAS- MCF: WATER - BBL: PROD. METHOD.RATES:
CHOKE SIZE TBG. PRESS. CSG. PRESS. PI GRAVITY BTU- GAS GASIOIL RATIO 24 HR PRODUCTlON OIL- BBL: GAS - MDF: WATER - BBL: INTERVALSTATUSRATES: -+
32. DISPDSITION OF GAS {Sold, Used for Fuel, Vented, Etc.)
vented walting on gas connection33, SUMMARYOF POROUS zONES(Inc1ude Aquifers): 34. FORMATION(Log) MARKERS;
Shaw all important zones ofporosity andcontentsthereof Cored intervals and all drill-stem lests, includingdepth interval tested,cushion used, timetuoiopen, ilowing and shut·in pressures and recoveries.
Formation a o Descriptions, Contents, etc Name (MeasuodpDepth)
Dakota 0 140 sandstone fine grain occasional dark miMorrison 140 868 poorly sorted varigated red, green anchEntrada 868 sandstone fine grain light gray
35. ADDITIONA1.REMARKS {Include plugging procedure)
Morrison Formation 577-580 Flow tested while drilling:1st flow 1.18 MCFD for 15 min @25.5 PSIA 1st SI 15 min built to 88 PSIA
-36. I hereby certlfy that thefaragaing and attached information is complete and correct as determined from allavailablerecords.
NAME PULEASEPR J EV vir s Managing Director
This repo ust ubmi within days of• co g a well e reentering a previously plugged and abandoned welle drillinghorizontal lat m an existing well bare • significantlydeepening an existing well bore below the previous bottom-hole deptha recompleting to a different producing formation • drilling hydrocarbon exploratory holes, such as core samples and stratigraphic tests
* ITEM 20: Show the number of completions if productlon is measured separately from twoor more formations.
** ITEM24: Cement Top - Show how reported top(s)ofcement were determined (circulated (CIR), calculated (CAL}, cement bond log (CBL). temperaturesurvey (TS)).
Send to: Utah Division of Oil, Gas and Minlng Phone 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City. Utah 84114-5801
31. INITIAL PRODUCTION INTERVALA {As shown in item #26}
DATEFIRST PRODUCED TEST DATE HOURS TESTED TEST PRODUCTION DIL - BBL GAS - MCF: WATER - BBL PROD. METHOD
8/12/2013 8/14/2013 3 RATES 0 245 0 ventedCHOKE SIZE TBG PRESS. CSG. PRESS. API GRAVITY BTU- GAS GASIOILRATIO 24 HR PRODUCTION DIL - BBL: GAS - MCF WATER- BBL INTERVALSTATUS
129 RATES O 1,964 0 SI w.o. gasa
INTERYALB (As shawn In liem #26)
DATEFIRST PRODUCED TEST DATE HOURS TESTEO: TEST PRODUCTION OIL - BBI GAS - MGF; WATER - BBL: PROD METHODRATES: -+
CHOKE SIZE: TBG. PRESS. CSG. PRESS, PI GRAVITY BTU - GAS GAS/OIL RATIO 24 HR PRODUCTION DIL- BBL: GAS - MCF: WATER - BBL: INTERVALSTATUSRATES: *
INTERVAL C (As shown In Item?26)
DATE FIRST PRODUCED TEST DATE; HOURS TESTED: TEST PRODUCTION OIL - BEIL: GAS - MCF: WATER -- BBL: PROD. METHODRATES: -+
CHOKESIZE TBG. PRESS. CSG. PRES5. PI GRAVITY BTU- GAS GAS/OILRATIO 24 HR PRODUCTION OIL - BEL: GAS - MCF: WATER - BBL: INTERVAL STATUSRATES; *
INTERVALD (As shown in Item #26)
DATE FIRST PRODUCED TEST DATE: MOURSTESTED: TEST PRODUCTION OIL- BBL: GAS- MCF: WATER - BBL: PROD. METHOD.RATES:
CHOKE SIZE TBG. PRESS. CSG. PRESS. PI GRAVITY BTU- GAS GASIOIL RATIO 24 HR PRODUCTlON OIL- BBL: GAS - MDF: WATER - BBL: INTERVALSTATUSRATES: -+
32. DISPDSITION OF GAS {Sold, Used for Fuel, Vented, Etc.)
vented walting on gas connection33, SUMMARYOF POROUS zONES(Inc1ude Aquifers): 34. FORMATION(Log) MARKERS;
Shaw all important zones ofporosity andcontentsthereof Cored intervals and all drill-stem lests, includingdepth interval tested,cushion used, timetuoiopen, ilowing and shut·in pressures and recoveries.
Formation a o Descriptions, Contents, etc Name (MeasuodpDepth)
Dakota 0 140 sandstone fine grain occasional dark miMorrison 140 868 poorly sorted varigated red, green anchEntrada 868 sandstone fine grain light gray
35. ADDITIONA1.REMARKS {Include plugging procedure)
Morrison Formation 577-580 Flow tested while drilling:1st flow 1.18 MCFD for 15 min @25.5 PSIA 1st SI 15 min built to 88 PSIA
-36. I hereby certlfy that thefaragaing and attached information is complete and correct as determined from allavailablerecords.
NAME PULEASEPR J EV vir s Managing Director
This repo ust ubmi within days of• co g a well e reentering a previously plugged and abandoned welle drillinghorizontal lat m an existing well bare • significantlydeepening an existing well bore below the previous bottom-hole deptha recompleting to a different producing formation • drilling hydrocarbon exploratory holes, such as core samples and stratigraphic tests
* ITEM 20: Show the number of completions if productlon is measured separately from twoor more formations.
** ITEM24: Cement Top - Show how reported top(s)ofcement were determined (circulated (CIR), calculated (CAL}, cement bond log (CBL). temperaturesurvey (TS)).
Send to: Utah Division of Oil, Gas and Minlng Phone 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City. Utah 84114-5801
31. INITIAL PRODUCTION INTERVALA {As shown in item #26}
DATEFIRST PRODUCED TEST DATE HOURS TESTED TEST PRODUCTION DIL - BBL GAS - MCF: WATER - BBL PROD. METHOD
8/12/2013 8/14/2013 3 RATES 0 245 0 ventedCHOKE SIZE TBG PRESS. CSG. PRESS. API GRAVITY BTU- GAS GASIOILRATIO 24 HR PRODUCTION DIL - BBL: GAS - MCF WATER- BBL INTERVALSTATUS
129 RATES O 1,964 0 SI w.o. gasa
INTERYALB (As shawn In liem #26)
DATEFIRST PRODUCED TEST DATE HOURS TESTEO: TEST PRODUCTION OIL - BBI GAS - MGF; WATER - BBL: PROD METHODRATES: -+
CHOKE SIZE: TBG. PRESS. CSG. PRESS, PI GRAVITY BTU - GAS GAS/OIL RATIO 24 HR PRODUCTION DIL- BBL: GAS - MCF: WATER - BBL: INTERVALSTATUSRATES: *
INTERVAL C (As shown In Item?26)
DATE FIRST PRODUCED TEST DATE; HOURS TESTED: TEST PRODUCTION OIL - BEIL: GAS - MCF: WATER -- BBL: PROD. METHODRATES: -+
CHOKESIZE TBG. PRESS. CSG. PRES5. PI GRAVITY BTU- GAS GAS/OILRATIO 24 HR PRODUCTION OIL - BEL: GAS - MCF: WATER - BBL: INTERVAL STATUSRATES; *
INTERVALD (As shown in Item #26)
DATE FIRST PRODUCED TEST DATE: MOURSTESTED: TEST PRODUCTION OIL- BBL: GAS- MCF: WATER - BBL: PROD. METHOD.RATES:
CHOKE SIZE TBG. PRESS. CSG. PRESS. PI GRAVITY BTU- GAS GASIOIL RATIO 24 HR PRODUCTlON OIL- BBL: GAS - MDF: WATER - BBL: INTERVALSTATUSRATES: -+
32. DISPDSITION OF GAS {Sold, Used for Fuel, Vented, Etc.)
vented walting on gas connection33, SUMMARYOF POROUS zONES(Inc1ude Aquifers): 34. FORMATION(Log) MARKERS;
Shaw all important zones ofporosity andcontentsthereof Cored intervals and all drill-stem lests, includingdepth interval tested,cushion used, timetuoiopen, ilowing and shut·in pressures and recoveries.
Formation a o Descriptions, Contents, etc Name (MeasuodpDepth)
Dakota 0 140 sandstone fine grain occasional dark miMorrison 140 868 poorly sorted varigated red, green anchEntrada 868 sandstone fine grain light gray
35. ADDITIONA1.REMARKS {Include plugging procedure)
Morrison Formation 577-580 Flow tested while drilling:1st flow 1.18 MCFD for 15 min @25.5 PSIA 1st SI 15 min built to 88 PSIA
-36. I hereby certlfy that thefaragaing and attached information is complete and correct as determined from allavailablerecords.
NAME PULEASEPR J EV vir s Managing Director
This repo ust ubmi within days of• co g a well e reentering a previously plugged and abandoned welle drillinghorizontal lat m an existing well bare • significantlydeepening an existing well bore below the previous bottom-hole deptha recompleting to a different producing formation • drilling hydrocarbon exploratory holes, such as core samples and stratigraphic tests
* ITEM 20: Show the number of completions if productlon is measured separately from twoor more formations.
** ITEM24: Cement Top - Show how reported top(s)ofcement were determined (circulated (CIR), calculated (CAL}, cement bond log (CBL). temperaturesurvey (TS)).
Send to: Utah Division of Oil, Gas and Minlng Phone 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City. Utah 84114-5801
31. INITIAL PRODUCTION INTERVALA {As shown in item #26}
DATEFIRST PRODUCED TEST DATE HOURS TESTED TEST PRODUCTION DIL - BBL GAS - MCF: WATER - BBL PROD. METHOD
8/12/2013 8/14/2013 3 RATES 0 245 0 ventedCHOKE SIZE TBG PRESS. CSG. PRESS. API GRAVITY BTU- GAS GASIOILRATIO 24 HR PRODUCTION DIL - BBL: GAS - MCF WATER- BBL INTERVALSTATUS
129 RATES O 1,964 0 SI w.o. gasa
INTERYALB (As shawn In liem #26)
DATEFIRST PRODUCED TEST DATE HOURS TESTEO: TEST PRODUCTION OIL - BBI GAS - MGF; WATER - BBL: PROD METHODRATES: -+
CHOKE SIZE: TBG. PRESS. CSG. PRESS, PI GRAVITY BTU - GAS GAS/OIL RATIO 24 HR PRODUCTION DIL- BBL: GAS - MCF: WATER - BBL: INTERVALSTATUSRATES: *
INTERVAL C (As shown In Item?26)
DATE FIRST PRODUCED TEST DATE; HOURS TESTED: TEST PRODUCTION OIL - BEIL: GAS - MCF: WATER -- BBL: PROD. METHODRATES: -+
CHOKESIZE TBG. PRESS. CSG. PRES5. PI GRAVITY BTU- GAS GAS/OILRATIO 24 HR PRODUCTION OIL - BEL: GAS - MCF: WATER - BBL: INTERVAL STATUSRATES; *
INTERVALD (As shown in Item #26)
DATE FIRST PRODUCED TEST DATE: MOURSTESTED: TEST PRODUCTION OIL- BBL: GAS- MCF: WATER - BBL: PROD. METHOD.RATES:
CHOKE SIZE TBG. PRESS. CSG. PRESS. PI GRAVITY BTU- GAS GASIOIL RATIO 24 HR PRODUCTlON OIL- BBL: GAS - MDF: WATER - BBL: INTERVALSTATUSRATES: -+
32. DISPDSITION OF GAS {Sold, Used for Fuel, Vented, Etc.)
vented walting on gas connection33, SUMMARYOF POROUS zONES(Inc1ude Aquifers): 34. FORMATION(Log) MARKERS;
Shaw all important zones ofporosity andcontentsthereof Cored intervals and all drill-stem lests, includingdepth interval tested,cushion used, timetuoiopen, ilowing and shut·in pressures and recoveries.
Formation a o Descriptions, Contents, etc Name (MeasuodpDepth)
Dakota 0 140 sandstone fine grain occasional dark miMorrison 140 868 poorly sorted varigated red, green anchEntrada 868 sandstone fine grain light gray
35. ADDITIONA1.REMARKS {Include plugging procedure)
Morrison Formation 577-580 Flow tested while drilling:1st flow 1.18 MCFD for 15 min @25.5 PSIA 1st SI 15 min built to 88 PSIA
-36. I hereby certlfy that thefaragaing and attached information is complete and correct as determined from allavailablerecords.
NAME PULEASEPR J EV vir s Managing Director
This repo ust ubmi within days of• co g a well e reentering a previously plugged and abandoned welle drillinghorizontal lat m an existing well bare • significantlydeepening an existing well bore below the previous bottom-hole deptha recompleting to a different producing formation • drilling hydrocarbon exploratory holes, such as core samples and stratigraphic tests
* ITEM 20: Show the number of completions if productlon is measured separately from twoor more formations.
** ITEM24: Cement Top - Show how reported top(s)ofcement were determined (circulated (CIR), calculated (CAL}, cement bond log (CBL). temperaturesurvey (TS)).
Send to: Utah Division of Oil, Gas and Minlng Phone 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City. Utah 84114-5801
31. INITIAL PRODUCTION INTERVALA {As shown in item #26}
DATEFIRST PRODUCED TEST DATE HOURS TESTED TEST PRODUCTION DIL - BBL GAS - MCF: WATER - BBL PROD. METHOD
8/12/2013 8/14/2013 3 RATES 0 245 0 ventedCHOKE SIZE TBG PRESS. CSG. PRESS. API GRAVITY BTU- GAS GASIOILRATIO 24 HR PRODUCTION DIL - BBL: GAS - MCF WATER- BBL INTERVALSTATUS
129 RATES O 1,964 0 SI w.o. gasa
INTERYALB (As shawn In liem #26)
DATEFIRST PRODUCED TEST DATE HOURS TESTEO: TEST PRODUCTION OIL - BBI GAS - MGF; WATER - BBL: PROD METHODRATES: -+
CHOKE SIZE: TBG. PRESS. CSG. PRESS, PI GRAVITY BTU - GAS GAS/OIL RATIO 24 HR PRODUCTION DIL- BBL: GAS - MCF: WATER - BBL: INTERVALSTATUSRATES: *
INTERVAL C (As shown In Item?26)
DATE FIRST PRODUCED TEST DATE; HOURS TESTED: TEST PRODUCTION OIL - BEIL: GAS - MCF: WATER -- BBL: PROD. METHODRATES: -+
CHOKESIZE TBG. PRESS. CSG. PRES5. PI GRAVITY BTU- GAS GAS/OILRATIO 24 HR PRODUCTION OIL - BEL: GAS - MCF: WATER - BBL: INTERVAL STATUSRATES; *
INTERVALD (As shown in Item #26)
DATE FIRST PRODUCED TEST DATE: MOURSTESTED: TEST PRODUCTION OIL- BBL: GAS- MCF: WATER - BBL: PROD. METHOD.RATES:
CHOKE SIZE TBG. PRESS. CSG. PRESS. PI GRAVITY BTU- GAS GASIOIL RATIO 24 HR PRODUCTlON OIL- BBL: GAS - MDF: WATER - BBL: INTERVALSTATUSRATES: -+
32. DISPDSITION OF GAS {Sold, Used for Fuel, Vented, Etc.)
vented walting on gas connection33, SUMMARYOF POROUS zONES(Inc1ude Aquifers): 34. FORMATION(Log) MARKERS;
Shaw all important zones ofporosity andcontentsthereof Cored intervals and all drill-stem lests, includingdepth interval tested,cushion used, timetuoiopen, ilowing and shut·in pressures and recoveries.
Formation a o Descriptions, Contents, etc Name (MeasuodpDepth)
Dakota 0 140 sandstone fine grain occasional dark miMorrison 140 868 poorly sorted varigated red, green anchEntrada 868 sandstone fine grain light gray
35. ADDITIONA1.REMARKS {Include plugging procedure)
Morrison Formation 577-580 Flow tested while drilling:1st flow 1.18 MCFD for 15 min @25.5 PSIA 1st SI 15 min built to 88 PSIA
-36. I hereby certlfy that thefaragaing and attached information is complete and correct as determined from allavailablerecords.
NAME PULEASEPR J EV vir s Managing Director
This repo ust ubmi within days of• co g a well e reentering a previously plugged and abandoned welle drillinghorizontal lat m an existing well bare • significantlydeepening an existing well bore below the previous bottom-hole deptha recompleting to a different producing formation • drilling hydrocarbon exploratory holes, such as core samples and stratigraphic tests
* ITEM 20: Show the number of completions if productlon is measured separately from twoor more formations.
** ITEM24: Cement Top - Show how reported top(s)ofcement were determined (circulated (CIR), calculated (CAL}, cement bond log (CBL). temperaturesurvey (TS)).
Send to: Utah Division of Oil, Gas and Minlng Phone 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City. Utah 84114-5801
31. INITIAL PRODUCTION INTERVALA {As shown in item #26}
DATEFIRST PRODUCED TEST DATE HOURS TESTED TEST PRODUCTION DIL - BBL GAS - MCF: WATER - BBL PROD. METHOD
8/12/2013 8/14/2013 3 RATES 0 245 0 ventedCHOKE SIZE TBG PRESS. CSG. PRESS. API GRAVITY BTU- GAS GASIOILRATIO 24 HR PRODUCTION DIL - BBL: GAS - MCF WATER- BBL INTERVALSTATUS
129 RATES O 1,964 0 SI w.o. gasa
INTERYALB (As shawn In liem #26)
DATEFIRST PRODUCED TEST DATE HOURS TESTEO: TEST PRODUCTION OIL - BBI GAS - MGF; WATER - BBL: PROD METHODRATES: -+
CHOKE SIZE: TBG. PRESS. CSG. PRESS, PI GRAVITY BTU - GAS GAS/OIL RATIO 24 HR PRODUCTION DIL- BBL: GAS - MCF: WATER - BBL: INTERVALSTATUSRATES: *
INTERVAL C (As shown In Item?26)
DATE FIRST PRODUCED TEST DATE; HOURS TESTED: TEST PRODUCTION OIL - BEIL: GAS - MCF: WATER -- BBL: PROD. METHODRATES: -+
CHOKESIZE TBG. PRESS. CSG. PRES5. PI GRAVITY BTU- GAS GAS/OILRATIO 24 HR PRODUCTION OIL - BEL: GAS - MCF: WATER - BBL: INTERVAL STATUSRATES; *
INTERVALD (As shown in Item #26)
DATE FIRST PRODUCED TEST DATE: MOURSTESTED: TEST PRODUCTION OIL- BBL: GAS- MCF: WATER - BBL: PROD. METHOD.RATES:
CHOKE SIZE TBG. PRESS. CSG. PRESS. PI GRAVITY BTU- GAS GASIOIL RATIO 24 HR PRODUCTlON OIL- BBL: GAS - MDF: WATER - BBL: INTERVALSTATUSRATES: -+
32. DISPDSITION OF GAS {Sold, Used for Fuel, Vented, Etc.)
vented walting on gas connection33, SUMMARYOF POROUS zONES(Inc1ude Aquifers): 34. FORMATION(Log) MARKERS;
Shaw all important zones ofporosity andcontentsthereof Cored intervals and all drill-stem lests, includingdepth interval tested,cushion used, timetuoiopen, ilowing and shut·in pressures and recoveries.
Formation a o Descriptions, Contents, etc Name (MeasuodpDepth)
Dakota 0 140 sandstone fine grain occasional dark miMorrison 140 868 poorly sorted varigated red, green anchEntrada 868 sandstone fine grain light gray
35. ADDITIONA1.REMARKS {Include plugging procedure)
Morrison Formation 577-580 Flow tested while drilling:1st flow 1.18 MCFD for 15 min @25.5 PSIA 1st SI 15 min built to 88 PSIA
-36. I hereby certlfy that thefaragaing and attached information is complete and correct as determined from allavailablerecords.
NAME PULEASEPR J EV vir s Managing Director
This repo ust ubmi within days of• co g a well e reentering a previously plugged and abandoned welle drillinghorizontal lat m an existing well bare • significantlydeepening an existing well bore below the previous bottom-hole deptha recompleting to a different producing formation • drilling hydrocarbon exploratory holes, such as core samples and stratigraphic tests
* ITEM 20: Show the number of completions if productlon is measured separately from twoor more formations.
** ITEM24: Cement Top - Show how reported top(s)ofcement were determined (circulated (CIR), calculated (CAL}, cement bond log (CBL). temperaturesurvey (TS)).
Send to: Utah Division of Oil, Gas and Minlng Phone 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City. Utah 84114-5801
31. INITIAL PRODUCTION INTERVALA {As shown in item #26}
DATEFIRST PRODUCED TEST DATE HOURS TESTED TEST PRODUCTION DIL - BBL GAS - MCF: WATER - BBL PROD. METHOD
8/12/2013 8/14/2013 3 RATES 0 245 0 ventedCHOKE SIZE TBG PRESS. CSG. PRESS. API GRAVITY BTU- GAS GASIOILRATIO 24 HR PRODUCTION DIL - BBL: GAS - MCF WATER- BBL INTERVALSTATUS
129 RATES O 1,964 0 SI w.o. gasa
INTERYALB (As shawn In liem #26)
DATEFIRST PRODUCED TEST DATE HOURS TESTEO: TEST PRODUCTION OIL - BBI GAS - MGF; WATER - BBL: PROD METHODRATES: -+
CHOKE SIZE: TBG. PRESS. CSG. PRESS, PI GRAVITY BTU - GAS GAS/OIL RATIO 24 HR PRODUCTION DIL- BBL: GAS - MCF: WATER - BBL: INTERVALSTATUSRATES: *
INTERVAL C (As shown In Item?26)
DATE FIRST PRODUCED TEST DATE; HOURS TESTED: TEST PRODUCTION OIL - BEIL: GAS - MCF: WATER -- BBL: PROD. METHODRATES: -+
CHOKESIZE TBG. PRESS. CSG. PRES5. PI GRAVITY BTU- GAS GAS/OILRATIO 24 HR PRODUCTION OIL - BEL: GAS - MCF: WATER - BBL: INTERVAL STATUSRATES; *
INTERVALD (As shown in Item #26)
DATE FIRST PRODUCED TEST DATE: MOURSTESTED: TEST PRODUCTION OIL- BBL: GAS- MCF: WATER - BBL: PROD. METHOD.RATES:
CHOKE SIZE TBG. PRESS. CSG. PRESS. PI GRAVITY BTU- GAS GASIOIL RATIO 24 HR PRODUCTlON OIL- BBL: GAS - MDF: WATER - BBL: INTERVALSTATUSRATES: -+
32. DISPDSITION OF GAS {Sold, Used for Fuel, Vented, Etc.)
vented walting on gas connection33, SUMMARYOF POROUS zONES(Inc1ude Aquifers): 34. FORMATION(Log) MARKERS;
Shaw all important zones ofporosity andcontentsthereof Cored intervals and all drill-stem lests, includingdepth interval tested,cushion used, timetuoiopen, ilowing and shut·in pressures and recoveries.
Formation a o Descriptions, Contents, etc Name (MeasuodpDepth)
Dakota 0 140 sandstone fine grain occasional dark miMorrison 140 868 poorly sorted varigated red, green anchEntrada 868 sandstone fine grain light gray
35. ADDITIONA1.REMARKS {Include plugging procedure)
Morrison Formation 577-580 Flow tested while drilling:1st flow 1.18 MCFD for 15 min @25.5 PSIA 1st SI 15 min built to 88 PSIA
-36. I hereby certlfy that thefaragaing and attached information is complete and correct as determined from allavailablerecords.
NAME PULEASEPR J EV vir s Managing Director
This repo ust ubmi within days of• co g a well e reentering a previously plugged and abandoned welle drillinghorizontal lat m an existing well bare • significantlydeepening an existing well bore below the previous bottom-hole deptha recompleting to a different producing formation • drilling hydrocarbon exploratory holes, such as core samples and stratigraphic tests
* ITEM 20: Show the number of completions if productlon is measured separately from twoor more formations.
** ITEM24: Cement Top - Show how reported top(s)ofcement were determined (circulated (CIR), calculated (CAL}, cement bond log (CBL). temperaturesurvey (TS)).
Send to: Utah Division of Oil, Gas and Minlng Phone 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City. Utah 84114-5801
31. INITIAL PRODUCTION INTERVALA {As shown in item #26}
DATEFIRST PRODUCED TEST DATE HOURS TESTED TEST PRODUCTION DIL - BBL GAS - MCF: WATER - BBL PROD. METHOD
8/12/2013 8/14/2013 3 RATES 0 245 0 ventedCHOKE SIZE TBG PRESS. CSG. PRESS. API GRAVITY BTU- GAS GASIOILRATIO 24 HR PRODUCTION DIL - BBL: GAS - MCF WATER- BBL INTERVALSTATUS
129 RATES O 1,964 0 SI w.o. gasa
INTERYALB (As shawn In liem #26)
DATEFIRST PRODUCED TEST DATE HOURS TESTEO: TEST PRODUCTION OIL - BBI GAS - MGF; WATER - BBL: PROD METHODRATES: -+
CHOKE SIZE: TBG. PRESS. CSG. PRESS, PI GRAVITY BTU - GAS GAS/OIL RATIO 24 HR PRODUCTION DIL- BBL: GAS - MCF: WATER - BBL: INTERVALSTATUSRATES: *
INTERVAL C (As shown In Item?26)
DATE FIRST PRODUCED TEST DATE; HOURS TESTED: TEST PRODUCTION OIL - BEIL: GAS - MCF: WATER -- BBL: PROD. METHODRATES: -+
CHOKESIZE TBG. PRESS. CSG. PRES5. PI GRAVITY BTU- GAS GAS/OILRATIO 24 HR PRODUCTION OIL - BEL: GAS - MCF: WATER - BBL: INTERVAL STATUSRATES; *
INTERVALD (As shown in Item #26)
DATE FIRST PRODUCED TEST DATE: MOURSTESTED: TEST PRODUCTION OIL- BBL: GAS- MCF: WATER - BBL: PROD. METHOD.RATES:
CHOKE SIZE TBG. PRESS. CSG. PRESS. PI GRAVITY BTU- GAS GASIOIL RATIO 24 HR PRODUCTlON OIL- BBL: GAS - MDF: WATER - BBL: INTERVALSTATUSRATES: -+
32. DISPDSITION OF GAS {Sold, Used for Fuel, Vented, Etc.)
vented walting on gas connection33, SUMMARYOF POROUS zONES(Inc1ude Aquifers): 34. FORMATION(Log) MARKERS;
Shaw all important zones ofporosity andcontentsthereof Cored intervals and all drill-stem lests, includingdepth interval tested,cushion used, timetuoiopen, ilowing and shut·in pressures and recoveries.
Formation a o Descriptions, Contents, etc Name (MeasuodpDepth)
Dakota 0 140 sandstone fine grain occasional dark miMorrison 140 868 poorly sorted varigated red, green anchEntrada 868 sandstone fine grain light gray
35. ADDITIONA1.REMARKS {Include plugging procedure)
Morrison Formation 577-580 Flow tested while drilling:1st flow 1.18 MCFD for 15 min @25.5 PSIA 1st SI 15 min built to 88 PSIA
-36. I hereby certlfy that thefaragaing and attached information is complete and correct as determined from allavailablerecords.
NAME PULEASEPR J EV vir s Managing Director
This repo ust ubmi within days of• co g a well e reentering a previously plugged and abandoned welle drillinghorizontal lat m an existing well bare • significantlydeepening an existing well bore below the previous bottom-hole deptha recompleting to a different producing formation • drilling hydrocarbon exploratory holes, such as core samples and stratigraphic tests
* ITEM 20: Show the number of completions if productlon is measured separately from twoor more formations.
** ITEM24: Cement Top - Show how reported top(s)ofcement were determined (circulated (CIR), calculated (CAL}, cement bond log (CBL). temperaturesurvey (TS)).
Send to: Utah Division of Oil, Gas and Minlng Phone 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City. Utah 84114-5801
31. INITIAL PRODUCTION INTERVALA {As shown in item #26}
DATEFIRST PRODUCED TEST DATE HOURS TESTED TEST PRODUCTION DIL - BBL GAS - MCF: WATER - BBL PROD. METHOD
8/12/2013 8/14/2013 3 RATES 0 245 0 ventedCHOKE SIZE TBG PRESS. CSG. PRESS. API GRAVITY BTU- GAS GASIOILRATIO 24 HR PRODUCTION DIL - BBL: GAS - MCF WATER- BBL INTERVALSTATUS
129 RATES O 1,964 0 SI w.o. gasa
INTERYALB (As shawn In liem #26)
DATEFIRST PRODUCED TEST DATE HOURS TESTEO: TEST PRODUCTION OIL - BBI GAS - MGF; WATER - BBL: PROD METHODRATES: -+
CHOKE SIZE: TBG. PRESS. CSG. PRESS, PI GRAVITY BTU - GAS GAS/OIL RATIO 24 HR PRODUCTION DIL- BBL: GAS - MCF: WATER - BBL: INTERVALSTATUSRATES: *
INTERVAL C (As shown In Item?26)
DATE FIRST PRODUCED TEST DATE; HOURS TESTED: TEST PRODUCTION OIL - BEIL: GAS - MCF: WATER -- BBL: PROD. METHODRATES: -+
CHOKESIZE TBG. PRESS. CSG. PRES5. PI GRAVITY BTU- GAS GAS/OILRATIO 24 HR PRODUCTION OIL - BEL: GAS - MCF: WATER - BBL: INTERVAL STATUSRATES; *
INTERVALD (As shown in Item #26)
DATE FIRST PRODUCED TEST DATE: MOURSTESTED: TEST PRODUCTION OIL- BBL: GAS- MCF: WATER - BBL: PROD. METHOD.RATES:
CHOKE SIZE TBG. PRESS. CSG. PRESS. PI GRAVITY BTU- GAS GASIOIL RATIO 24 HR PRODUCTlON OIL- BBL: GAS - MDF: WATER - BBL: INTERVALSTATUSRATES: -+
32. DISPDSITION OF GAS {Sold, Used for Fuel, Vented, Etc.)
vented walting on gas connection33, SUMMARYOF POROUS zONES(Inc1ude Aquifers): 34. FORMATION(Log) MARKERS;
Shaw all important zones ofporosity andcontentsthereof Cored intervals and all drill-stem lests, includingdepth interval tested,cushion used, timetuoiopen, ilowing and shut·in pressures and recoveries.
Formation a o Descriptions, Contents, etc Name (MeasuodpDepth)
Dakota 0 140 sandstone fine grain occasional dark miMorrison 140 868 poorly sorted varigated red, green anchEntrada 868 sandstone fine grain light gray
35. ADDITIONA1.REMARKS {Include plugging procedure)
Morrison Formation 577-580 Flow tested while drilling:1st flow 1.18 MCFD for 15 min @25.5 PSIA 1st SI 15 min built to 88 PSIA
-36. I hereby certlfy that thefaragaing and attached information is complete and correct as determined from allavailablerecords.
NAME PULEASEPR J EV vir s Managing Director
This repo ust ubmi within days of• co g a well • reentering a previously plugged and abandoned welle drilling horizontal lat m an existing well bore • significantly deepening an existing well bore below the previous bottom-hole deptha recompleting to a different producing formation • drillinghydrocarbon exploratory holes, such as core samples and stratigraphic tests
* ITEM 20: Show the number of completions if productlon is measured separately from twoor more formations.
** ITEM 24: Cement Top - Show how reported top(s)of cement were determined (circulated (CIR).calculated (CAL}, cement bond log (CBL), temperaturesurvey (TS)).
Send to: Utah Divisionof Oil, Gas and MinIng Phone 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City. Utah 84114-5801
31. INITIAL PRODUCTION INTERVALA {As shown in item #26}
DATEFIRST PRODUCED TEST DATE HOURS TESTED TEST PRODUCTION DIL - BBL GAS - MCF: WATER - BBL PROD. METHOD
8/12/2013 8/14/2013 3 RATES 0 245 0 ventedCHOKE SIZE TBG PRESS. CSG. PRESS. API GRAVITY BTU- GAS GASIOILRATIO 24 HR PRODUCTION DIL - BBL: GAS - MCF WATER- BBL INTERVALSTATUS
129 RATES O 1,964 0 SI w.o. gasa
INTERYALB (As shawn In liem #26)
DATEFIRST PRODUCED TEST DATE HOURS TESTEO: TEST PRODUCTION OIL - BBI GAS - MGF; WATER - BBL: PROD METHODRATES: -+
CHOKE SIZE: TBG. PRESS. CSG. PRESS, PI GRAVITY BTU - GAS GAS/OIL RATIO 24 HR PRODUCTION DIL- BBL: GAS - MCF: WATER - BBL: INTERVALSTATUSRATES: *
INTERVAL C (As shown In Item?26)
DATE FIRST PRODUCED TEST DATE; HOURS TESTED: TEST PRODUCTION OIL - BEIL: GAS - MCF: WATER -- BBL: PROD. METHODRATES: -+
CHOKESIZE TBG. PRESS. CSG. PRES5. PI GRAVITY BTU- GAS GAS/OILRATIO 24 HR PRODUCTION OIL - BEL: GAS - MCF: WATER - BBL: INTERVAL STATUSRATES; *
INTERVALD (As shown in Item #26)
DATE FIRST PRODUCED TEST DATE: MOURSTESTED: TEST PRODUCTION OIL- BBL: GAS- MCF: WATER - BBL: PROD. METHOD.RATES:
CHOKE SIZE TBG. PRESS. CSG. PRESS. PI GRAVITY BTU- GAS GASIOIL RATIO 24 HR PRODUCTlON OIL- BBL: GAS - MDF: WATER - BBL: INTERVALSTATUSRATES: -+
32. DISPDSITION OF GAS {Sold, Used for Fuel, Vented, Etc.)
vented walting on gas connection33, SUMMARYOF POROUS zONES(Inc1ude Aquifers): 34. FORMATION(Log) MARKERS;
Shaw all important zones ofporosity andcontentsthereof Cored intervals and all drill-stem lests, includingdepth interval tested,cushion used, timetuoiopen, ilowing and shut·in pressures and recoveries.
Formation a o Descriptions, Contents, etc Name (MeasuodpDepth)
Dakota 0 140 sandstone fine grain occasional dark miMorrison 140 868 poorly sorted varigated red, green anchEntrada 868 sandstone fine grain light gray
35. ADDITIONA1.REMARKS {Include plugging procedure)
Morrison Formation 577-580 Flow tested while drilling:1st flow 1.18 MCFD for 15 min @25.5 PSIA 1st SI 15 min built to 88 PSIA
-36. I hereby certlfy that thefaragaing and attached information is complete and correct as determined from allavailablerecords.
NAME PULEASEPR J EV vir s Managing Director
This repo ust ubmi within days of• co g a well • reentering a previously plugged and abandoned welle drilling horizontal lat m an existing well bore • significantly deepening an existing well bore below the previous bottom-hole deptha recompleting to a different producing formation • drillinghydrocarbon exploratory holes, such as core samples and stratigraphic tests
* ITEM 20: Show the number of completions if productlon is measured separately from twoor more formations.
** ITEM 24: Cement Top - Show how reported top(s)of cement were determined (circulated (CIR).calculated (CAL}, cement bond log (CBL), temperaturesurvey (TS)).
Send to: Utah Divisionof Oil, Gas and MinIng Phone 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City. Utah 84114-5801
31. INITIAL PRODUCTION INTERVALA {As shown in item #26}
DATEFIRST PRODUCED TEST DATE HOURS TESTED TEST PRODUCTION DIL - BBL GAS - MCF: WATER - BBL PROD. METHOD
8/12/2013 8/14/2013 3 RATES 0 245 0 ventedCHOKE SIZE TBG PRESS. CSG. PRESS. API GRAVITY BTU- GAS GASIOILRATIO 24 HR PRODUCTION DIL - BBL: GAS - MCF WATER- BBL INTERVALSTATUS
129 RATES O 1,964 0 SI w.o. gasa
INTERYALB (As shawn In liem #26)
DATEFIRST PRODUCED TEST DATE HOURS TESTEO: TEST PRODUCTION OIL - BBI GAS - MGF; WATER - BBL: PROD METHODRATES: -+
CHOKE SIZE: TBG. PRESS. CSG. PRESS, PI GRAVITY BTU - GAS GAS/OIL RATIO 24 HR PRODUCTION DIL- BBL: GAS - MCF: WATER - BBL: INTERVALSTATUSRATES: *
INTERVAL C (As shown In Item?26)
DATE FIRST PRODUCED TEST DATE; HOURS TESTED: TEST PRODUCTION OIL - BEIL: GAS - MCF: WATER -- BBL: PROD. METHODRATES: -+
CHOKESIZE TBG. PRESS. CSG. PRES5. PI GRAVITY BTU- GAS GAS/OILRATIO 24 HR PRODUCTION OIL - BEL: GAS - MCF: WATER - BBL: INTERVAL STATUSRATES; *
INTERVALD (As shown in Item #26)
DATE FIRST PRODUCED TEST DATE: MOURSTESTED: TEST PRODUCTION OIL- BBL: GAS- MCF: WATER - BBL: PROD. METHOD.RATES:
CHOKE SIZE TBG. PRESS. CSG. PRESS. PI GRAVITY BTU- GAS GASIOIL RATIO 24 HR PRODUCTlON OIL- BBL: GAS - MDF: WATER - BBL: INTERVALSTATUSRATES: -+
32. DISPDSITION OF GAS {Sold, Used for Fuel, Vented, Etc.)
vented walting on gas connection33, SUMMARYOF POROUS zONES(Inc1ude Aquifers): 34. FORMATION(Log) MARKERS;
Shaw all important zones ofporosity andcontentsthereof Cored intervals and all drill-stem lests, includingdepth interval tested,cushion used, timetuoiopen, ilowing and shut·in pressures and recoveries.
Formation a o Descriptions, Contents, etc Name (MeasuodpDepth)
Dakota 0 140 sandstone fine grain occasional dark miMorrison 140 868 poorly sorted varigated red, green anchEntrada 868 sandstone fine grain light gray
35. ADDITIONA1.REMARKS {Include plugging procedure)
Morrison Formation 577-580 Flow tested while drilling:1st flow 1.18 MCFD for 15 min @25.5 PSIA 1st SI 15 min built to 88 PSIA
-36. I hereby certlfy that thefaragaing and attached information is complete and correct as determined from allavailablerecords.
NAME PULEASEPR J EV vir s Managing Director
This repo ust ubmi within days of• co g a well • reentering a previously plugged and abandoned welle drilling horizontal lat m an existing well bore • significantly deepening an existing well bore below the previous bottom-hole deptha recompleting to a different producing formation • drillinghydrocarbon exploratory holes, such as core samples and stratigraphic tests
* ITEM 20: Show the number of completions if productlon is measured separately from twoor more formations.
** ITEM 24: Cement Top - Show how reported top(s)of cement were determined (circulated (CIR).calculated (CAL}, cement bond log (CBL), temperaturesurvey (TS)).
Send to: Utah Divisionof Oil, Gas and MinIng Phone 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City. Utah 84114-5801
STATE OF UTAH DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING
SUNDRY NOTICES AND REPORTS ON WELLS
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILL form for such proposals.
1. TYPE OF WELL OIL WELL 0 GASWELL 0 OTHER helium
2. NAME OF OPERATOR:
Flatirons Resources LLC
3. ADDRESS OF OPERATOR:
110S0 Circle Point Road #1S'CITY Westminster STATE CO ZIP80020
I PHONE NUMBER:
I (303) 292-3902
4. LOCATION OF WELL
FOOTAGES AT SURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E
QTRlQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E
FORM 9
5. LEASE DESIGNATION AND SERIAL NUMBER:
UTU 87659
6. IF INDIAN, ALLOTIEE OR TRIBE NAME:
7. UNIT or CA AGREEMENT NAME:
8. WELL NAME and NUMBER:
Flatirons Federal #1-4
9. API NUMBER:
4301950029
10. FIELD AND POOL, OR WILDCAT:
Greater Cisco
COUNTY: Grand County
STATE: UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION
o NOTICE OF INTENT (Submitin Duplicate)
Approximate date work will start:
III SUBSEQUENT REPORT (Submit Original Form Only)
Date of work completion:
3/23/2015
o ACIDIZE
o ALTER CASING
D CASING REPAIR
o CHANGE TO PREVIOUS PLANS
D CHANGE TUBING
D CHANGE WELL NAME
o CHANGE WELL STATUS
o COMMINGLE PRODUCING FORMATIONS
o CONVERT WELL TYPE
TYPE OF ACTION
o DEEPEN
o FRACTURE TREAT
o NEW CONSTRUCTION
o OPERATOR CHANGE
o PLUG AND ABANDON
o PLUG BACK
o PRODUCTION (STARTIRESUME)
o RECLAMATION OF WELL SITE
o RECOMPLETE - DIFFERENT FORMATION
. 0 REPERFORATE CURRENT FORMATION
\0 SIDETRACK TO REPAIR WELL
o TEMPORARILY ABANDON
o TUBING REPAIR
o VENT OR FLARE
D WATER DISPOSAL
D WATERSHUT-OFF
Il1 OTHER: Orifice Plate Change
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show aU pertinent details including dates, depths, volumes, etc.
The orifice plate was changed to increase the differential pressure from 0.750 to 0.625
Jeffery E. Jones TITLE Managing Director
SIGNATURE_...;:...!;4;,.....::=¥-::?'..J.£._f--_____________ _ DATE 3/30/2015
(ThIs space for
(5/2000) (See Instructions on Reverse Side)
RECEIVED APR 06 2015
DW OF OIL, GAS & MINING
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITor CA AGREEMENT NAME:Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL Ü OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
ECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Orifice Plate Change3/23/2015 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearlyshow all pertinent details including dates, depths, volumes, etc.
The orifice plate was changed to increase the differential pressure from 0.750 to 0.625
RECEWEDAPRQg ggy
DIVOFOIL,GAS&MINING
NAMF (PI FASF PRINT) Jeffery E. Jones TITLE Managing Director
SIGNATIIRF DATE 3/30/2015
for
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITor CA AGREEMENT NAME:Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL Ü OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
ECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Orifice Plate Change3/23/2015 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearlyshow all pertinent details including dates, depths, volumes, etc.
The orifice plate was changed to increase the differential pressure from 0.750 to 0.625
RECEWEDAPRQg ggy
DIVOFOIL,GAS&MINING
NAMF (PI FASF PRINT) Jeffery E. Jones TITLE Managing Director
SIGNATIIRF DATE 3/30/2015
for
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITor CA AGREEMENT NAME:Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL Ü OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
ECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Orifice Plate Change3/23/2015 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearlyshow all pertinent details including dates, depths, volumes, etc.
The orifice plate was changed to increase the differential pressure from 0.750 to 0.625
RECEWEDAPRQg ggy
DIVOFOIL,GAS&MINING
NAMF (PI FASF PRINT) Jeffery E. Jones TITLE Managing Director
SIGNATIIRF DATE 3/30/2015
for
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITor CA AGREEMENT NAME:Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL Ü OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
ECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Orifice Plate Change3/23/2015 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearlyshow all pertinent details including dates, depths, volumes, etc.
The orifice plate was changed to increase the differential pressure from 0.750 to 0.625
RECEWEDAPRQg ggy
DIVOFOIL,GAS&MINING
NAMF (PI FASF PRINT) Jeffery E. Jones TITLE Managing Director
SIGNATIIRF DATE 3/30/2015
for
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITorCA AGREEMENT NAME:Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.1. TYPE OF WELL
OIL WELL GAS WELL Ü OTHER heliumF to
s7eddN1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
ECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Orifice Plate Change3/23/2015 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearlyshow all pertinent details including dates, depths, volumes, etc.
The orifice plate was changed to increase the differential pressure from 0.750 to 0.625
RECEWEDAPRQg ggy
DIVOFOIL,GAS&MINING
NAMF (PI FASF PRINT) Jeffery E. Jones TITLE Managing Director
SIGNATIIRF DATE 3/30/2015
for
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITorCA AGREEMENT NAME:Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.1. TYPE OF WELL
OIL WELL GAS WELL Ü OTHER heliumF to
s7eddN1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
ECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Orifice Plate Change3/23/2015 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearlyshow all pertinent details including dates, depths, volumes, etc.
The orifice plate was changed to increase the differential pressure from 0.750 to 0.625
RECEWEDAPRQg ggy
DIVOFOIL,GAS&MINING
NAMF (PI FASF PRINT) Jeffery E. Jones TITLE Managing Director
SIGNATIIRF DATE 3/30/2015
for
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITorCA AGREEMENT NAME:Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.1. TYPE OF WELL
OIL WELL GAS WELL Ü OTHER heliumF to
s7eddN1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
ECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Orifice Plate Change3/23/2015 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearlyshow all pertinent details including dates, depths, volumes, etc.
The orifice plate was changed to increase the differential pressure from 0.750 to 0.625
RECEWEDAPRQg ggy
DIVOFOIL,GAS&MINING
NAMF (PI FASF PRINT) Jeffery E. Jones TITLE Managing Director
SIGNATIIRF DATE 3/30/2015
for
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITorCA AGREEMENT NAME:Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.1. TYPE OF WELL
OIL WELL GAS WELL Ü OTHER heliumF to
s7eddN1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
ECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Orifice Plate Change3/23/2015 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearlyshow all pertinent details including dates, depths, volumes, etc.
The orifice plate was changed to increase the differential pressure from 0.750 to 0.625
RECEWEDAPRQg ggy
DIVOFOIL,GAS&MINING
NAMF (PI FASF PRINT) Jeffery E. Jones TITLE Managing Director
SIGNATIIRF DATE 3/30/2015
for
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITorCA AGREEMENT NAME:Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.1. TYPE OF WELL
OIL WELL GAS WELL Ü OTHER heliumF to
s7eddN1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
ECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Orifice Plate Change3/23/2015 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearlyshow all pertinent details including dates, depths, volumes, etc.
The orifice plate was changed to increase the differential pressure from 0.750 to 0.625
RECEWEDAPRQg ggy
DIVOFOIL,GAS&MINING
NAMF (PI FASF PRINT) Jeffery E. Jones TITLE Managing Director
SIGNATIIRF DATE 3/30/2015
for
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITorCA AGREEMENT NAME:Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.1. TYPE OF WELL
OIL WELL GAS WELL Ü OTHER heliumF to
s7eddN1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
ECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Orifice Plate Change3/23/2015 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearlyshow all pertinent details including dates, depths, volumes, etc.
The orifice plate was changed to increase the differential pressure from 0.750 to 0.625
RECEWEDAPRQg ggy
DIVOFOIL,GAS&MINING
NAMF (PI FASF PRINT) Jeffery E. Jones TITLE Managing Director
SIGNATIIRF DATE 3/30/2015
for
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITorCA AGREEMENT NAME:Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.1. TYPE OF WELL
OIL WELL GAS WELL Ü OTHER heliumF to
s7eddN1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
ECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Orifice Plate Change3/23/2015 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearlyshow all pertinent details including dates, depths, volumes, etc.
The orifice plate was changed to increase the differential pressure from 0.750 to 0.625
RECEWEDAPRQg ggy
DIVOFOIL,GAS&MINING
NAMF (PI FASF PRINT) Jeffery E. Jones TITLE Managing Director
SIGNATIIRF DATE 3/30/2015
for
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITorCA AGREEMENT NAME:Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.1. TYPE OF WELL
OIL WELL GAS WELL Ü OTHER heliumF to
s7eddN1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
ECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Orifice Plate Change3/23/2015 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearlyshow all pertinent details including dates, depths, volumes, etc.
The orifice plate was changed to increase the differential pressure from 0.750 to 0.625
RECEWEDAPRQg ggy
DIVOFOIL,GAS&MINING
NAMF (PI FASF PRINT) Jeffery E. Jones TITLE Managing Director
SIGNATIIRF DATE 3/30/2015
for
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITorCA AGREEMENT NAME:Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.1. TYPE OF WELL
OIL WELL GAS WELL Ü OTHER heliumF to
s7eddN1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
ECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Orifice Plate Change3/23/2015 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearlyshow all pertinent details including dates, depths, volumes, etc.
The orifice plate was changed to increase the differential pressure from 0.750 to 0.625
RECEWEDAPRQg ggy
DIVOFOIL,GAS&MINING
NAMF (PI FASF PRINT) Jeffery E. Jones TITLE Managing Director
SIGNATIIRF DATE 3/30/2015
for
(5/2000) (See Instructions on Reverse
INSTRUCTIONS
This form shall be submitted by the operator to show the intention and/or completion of the following: • miscellaneous work projects and actions for which other specific report forms do not exist; • all other work and events as identified in section 11, Type of Action, or as required by the Utah Oil and Gas
Conservation General Rules, including: - minor deepening of an existing well bore, - plugging back a well, - recompleting to a different producing formation within an existing well bore (intent only), - reperforating the current producing formation, - drilling a sidetrack to repair a well, - reporting monthly the status of each drilling well.
This form is not to be used for proposals to - drill new wells, - reenter previously plugged and abandoned wells, - significantly deepen existing wells below their current bottom-hole depth, - drill horizontal laterals from an existing well bore, - drill hydrocarbon exploratory holes such as core samples and stratigraphic tests.
Use Form 3, Application for Permit to Drill (APD) for such proposals.
NOTICE OF INTENT - A notice of intention to do work on a well or to change plans previously approved shall be submitted in duplicate and must be received and approved by the division before the work is commenced. The operator is responsible for receipt of the notice by the division in ample time for proper consideration and action. In cases of emergency, the operator may obtain verbal approval to commence work. Within five days after receiving verbal approval, the operator shall submit a Sundry Notice describing the work and acknowledging the verbal approval.
SUBSEQUENT REPORT - A subsequent report shall be submitted to the division within 30 days of the completion of the outlined work. Specific details of the work performed should be provided, including dates, well depths, placement of plugs, etc.
WELL ABANDONMENT - Proposals to abandon a well and subsequent reports of abandonment should include reasons for the abandonment; data on any former or present productive zones, or other zones with present significant fluid contents not sealed off by cement or otherwise; depths (top and bottom) and method of placement of cement plugs; mud or other material placed below, between and above plugs; amount, size, and method of parting of any casing, liner, or tubing pulled and the depth to top of any left in the hole; method of closing top of well; and date well site conditioned for final inspection looking to approval of the abandonment.
In addition to any Sundry Notice forms submitted, Form 8, Well Completion or Recompletion Report and Log must be submitted to the division to report the results of the following operations: • completing or plugging a new well, • reentering a previously plugged and abandoned well, • significantly deepening an existing well bore below the current bottom-hole depth, • drilling horizontal laterals from an existing well bore, • drilling hydrocarbon exploratory holes such as core samples and stratigraphic tests, • recompleting to a different producing formation.
Send to:
Utah Division of Oil, Gas and Mining 1594 West North Temple, Suite 1210 Box 145801 Salt Lake City, Utah 84114-5801
(512000)
Phone: 801-538-5340
Fax: 801-359-3940
INSTRUCTIONS
This form shall be submitted by the operator to show the intention and/or completion of the following:e miscellaneous work projects and actions for which other specific report forms do not exist;e all other work and events as identified in section 11, Type of Action, or as required by the Utah Oil and Gas
Conservation General Rules, including:- minor deepening of an existing well bore,- plugging back a well,- recompleting to a different producing formation withinan existing well bore (intent only),- reperforating the current producing formation,- drillinga sidetrack to repair a well,- reporting monthly the status of each drillingwell.
This form is not to be used for nronosals to- drillnew wells,- reenter previously plugged and abandoned wells,- significantlydeepen existing wells below theircurrent bottom-hole depth,- drillhorizontal laterals from an existing well bore,- drill hydrocarbon exploratory holes such as core samples and stratigraphic tests.
Use Form 3, Application for Permit to Drill (APD) for such proposals.
NOTICE OF INTENT - A notice of intention to do work on a well or to change plans previously approved shall besubmitted in duplicate and must be received and approved by the divisionbefore the work is commenced. The operatoris responsible for receipt of the notice by the division in ample timefor proper considerationand action. In cases ofemergency, the operator may obtain verbal approval to commence work. Withinfivedays after receivingverbal approval,the operator shall submit a Sundry Notice describing the work and acknowledging the verbal approval.
SUBSEQUENT REPORT - A subsequent report shall be submitted to the division within 30 days of the completion ofthe outlined work. Specific details of the work performed should be provided, including dates, well depths, placementof plugs, etc.
WELL ABANDONMENT - Proposals to abandon a well and subsequent reports of abandonment should include reasonsfor the abandonment; data on any former or present productive zones, or other zones with present significant fluidcontents not sealed off by cement or otherwise; depths (topand bottom) and method of placement of cement plugs;mud or other material placed below, between and above plugs; amount, size, and method of parting of any casing, liner,or tubingpulled and the depth to topof any left in the hole; method of closing top of well; and date well site conditionedfor final inspection looking to approval of the abandonment.
In addition to any Sundry Notice forms submitted, Form 8, Well Completion or Recompletion Report and Log mustbe submitted to the division to report the results of the followingoperations:• completing or plugging a new well,• reentering a previously plugged and abandoned well,• significantlydeepening an existing well bore below the current bottom-hole depth,e drilling horizontal laterals from an existing well bore,• drillinghydrocarbon exploratory holes such as core samples and stratigraphic tests,• recompleting to a different producing formation.
Send to:
Utah Divisionof Oil, Gas and Mining Phone: 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City, Utah 84114-5801
INSTRUCTIONS
This form shall be submitted by the operator to show the intention and/or completion of the following:e miscellaneous work projects and actions for which other specific report forms do not exist;e all other work and events as identified in section 11, Type of Action, or as required by the Utah Oil and Gas
Conservation General Rules, including:- minor deepening of an existing well bore,- plugging back a well,- recompleting to a different producing formation withinan existing well bore (intent only),- reperforating the current producing formation,- drillinga sidetrack to repair a well,- reporting monthly the status of each drillingwell.
This form is not to be used for nronosals to- drillnew wells,- reenter previously plugged and abandoned wells,- significantlydeepen existing wells below theircurrent bottom-hole depth,- drillhorizontal laterals from an existing well bore,- drill hydrocarbon exploratory holes such as core samples and stratigraphic tests.
Use Form 3, Application for Permit to Drill (APD) for such proposals.
NOTICE OF INTENT - A notice of intention to do work on a well or to change plans previously approved shall besubmitted in duplicate and must be received and approved by the divisionbefore the work is commenced. The operatoris responsible for receipt of the notice by the division in ample timefor proper considerationand action. In cases ofemergency, the operator may obtain verbal approval to commence work. Withinfivedays after receivingverbal approval,the operator shall submit a Sundry Notice describing the work and acknowledging the verbal approval.
SUBSEQUENT REPORT - A subsequent report shall be submitted to the division within 30 days of the completion ofthe outlined work. Specific details of the work performed should be provided, including dates, well depths, placementof plugs, etc.
WELL ABANDONMENT - Proposals to abandon a well and subsequent reports of abandonment should include reasonsfor the abandonment; data on any former or present productive zones, or other zones with present significant fluidcontents not sealed off by cement or otherwise; depths (topand bottom) and method of placement of cement plugs;mud or other material placed below, between and above plugs; amount, size, and method of parting of any casing, liner,or tubingpulled and the depth to topof any left in the hole; method of closing top of well; and date well site conditionedfor final inspection looking to approval of the abandonment.
In addition to any Sundry Notice forms submitted, Form 8, Well Completion or Recompletion Report and Log mustbe submitted to the division to report the results of the followingoperations:• completing or plugging a new well,• reentering a previously plugged and abandoned well,• significantlydeepening an existing well bore below the current bottom-hole depth,e drilling horizontal laterals from an existing well bore,• drillinghydrocarbon exploratory holes such as core samples and stratigraphic tests,• recompleting to a different producing formation.
Send to:
Utah Divisionof Oil, Gas and Mining Phone: 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City, Utah 84114-5801
INSTRUCTIONS
This form shall be submitted by the operator to show the intention and/or completion of the following:e miscellaneous work projects and actions for which other specific report forms do not exist;e all other work and events as identified in section 11, Type of Action, or as required by the Utah Oil and Gas
Conservation General Rules, including:- minor deepening of an existing well bore,- plugging back a well,- recompleting to a different producing formation withinan existing well bore (intent only),- reperforating the current producing formation,- drillinga sidetrack to repair a well,- reporting monthly the status of each drillingwell.
This form is not to be used for nronosals to- drillnew wells,- reenter previously plugged and abandoned wells,- significantlydeepen existing wells below theircurrent bottom-hole depth,- drillhorizontal laterals from an existing well bore,- drill hydrocarbon exploratory holes such as core samples and stratigraphic tests.
Use Form 3, Application for Permit to Drill (APD) for such proposals.
NOTICE OF INTENT - A notice of intention to do work on a well or to change plans previously approved shall besubmitted in duplicate and must be received and approved by the divisionbefore the work is commenced. The operatoris responsible for receipt of the notice by the division in ample timefor proper considerationand action. In cases ofemergency, the operator may obtain verbal approval to commence work. Withinfivedays after receivingverbal approval,the operator shall submit a Sundry Notice describing the work and acknowledging the verbal approval.
SUBSEQUENT REPORT - A subsequent report shall be submitted to the division within 30 days of the completion ofthe outlined work. Specific details of the work performed should be provided, including dates, well depths, placementof plugs, etc.
WELL ABANDONMENT - Proposals to abandon a well and subsequent reports of abandonment should include reasonsfor the abandonment; data on any former or present productive zones, or other zones with present significant fluidcontents not sealed off by cement or otherwise; depths (topand bottom) and method of placement of cement plugs;mud or other material placed below, between and above plugs; amount, size, and method of parting of any casing, liner,or tubingpulled and the depth to topof any left in the hole; method of closing top of well; and date well site conditionedfor final inspection looking to approval of the abandonment.
In addition to any Sundry Notice forms submitted, Form 8, Well Completion or Recompletion Report and Log mustbe submitted to the division to report the results of the followingoperations:• completing or plugging a new well,• reentering a previously plugged and abandoned well,• significantlydeepening an existing well bore below the current bottom-hole depth,e drilling horizontal laterals from an existing well bore,• drillinghydrocarbon exploratory holes such as core samples and stratigraphic tests,• recompleting to a different producing formation.
Send to:
Utah Divisionof Oil, Gas and Mining Phone: 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City, Utah 84114-5801
INSTRUCTIONS
This form shall be submitted by the operator to show the intention and/or completion of the following:e miscellaneous work projects and actions for which other specific report forms do not exist;e all other work and events as identified in section 11, Type of Action, or as required by the Utah Oil and Gas
Conservation General Rules, including:- minor deepening of an existing well bore,- plugging back a well,- recompleting to a different producing formation withinan existing well bore (intent only),- reperforating the current producing formation,- drillinga sidetrack to repair a well,- reporting monthly the status of each drillingwell.
This form is not to be used for nronosals to- drillnew wells,- reenter previously plugged and abandoned wells,- significantlydeepen existing wells below theircurrent bottom-hole depth,- drillhorizontal laterals from an existing well bore,- drill hydrocarbon exploratory holes such as core samples and stratigraphic tests.
Use Form 3, Application for Permit to Drill (APD) for such proposals.
NOTICE OF INTENT - A notice of intention to do work on a well or to change plans previously approved shall besubmitted in duplicate and must be received and approved by the divisionbefore the work is commenced. The operatoris responsible for receipt of the notice by the division in ample timefor proper considerationand action. In cases ofemergency, the operator may obtain verbal approval to commence work. Withinfivedays after receivingverbal approval,the operator shall submit a Sundry Notice describing the work and acknowledging the verbal approval.
SUBSEQUENT REPORT - A subsequent report shall be submitted to the division within 30 days of the completion ofthe outlined work. Specific details of the work performed should be provided, including dates, well depths, placementof plugs, etc.
WELL ABANDONMENT - Proposals to abandon a well and subsequent reports of abandonment should include reasonsfor the abandonment; data on any former or present productive zones, or other zones with present significant fluidcontents not sealed off by cement or otherwise; depths (topand bottom) and method of placement of cement plugs;mud or other material placed below, between and above plugs; amount, size, and method of parting of any casing, liner,or tubingpulled and the depth to topof any left in the hole; method of closing top of well; and date well site conditionedfor final inspection looking to approval of the abandonment.
In addition to any Sundry Notice forms submitted, Form 8, Well Completion or Recompletion Report and Log mustbe submitted to the division to report the results of the followingoperations:• completing or plugging a new well,• reentering a previously plugged and abandoned well,• significantlydeepening an existing well bore below the current bottom-hole depth,e drilling horizontal laterals from an existing well bore,• drillinghydrocarbon exploratory holes such as core samples and stratigraphic tests,• recompleting to a different producing formation.
Send to:
Utah Divisionof Oil, Gas and Mining Phone: 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City, Utah 84114-5801
INSTRUCTIONS
This form shall be submitted by the operator to show the intention and/or completion of the following:e miscellaneous work projects and actions for which other specific report forms do not exist;e all other work and events as identified in section 11, Type of Action, or as required by the Utah Oil and Gas
Conservation General Rules, including:- minor deepening of an existing well bore,- plugging back a well,- recompleting to a different producing formation withinan existing well bore (intent only),- reperforating the current producing formation,- drillinga sidetrack to repair a well,- reporting monthly the status of each drillingwell.
This form is not to be used for nronosals to- drillnew wells,- reenter previously plugged and abandoned wells,- significantlydeepen existing wells below theircurrent bottom-hole depth,- drillhorizontal laterals from an existing well bore,- drill hydrocarbon exploratory holes such as core samples and stratigraphic tests.
Use Form 3, Application for Permit to Drill (APD) for such proposals.
NOTICE OF INTENT - A notice of intention to do work on a well or to change plans previously approved shall besubmitted in duplicate and must be received and approved by the divisionbefore the work is commenced. The operatoris responsible for receipt of the notice by the division in ample timefor proper considerationand action. In cases ofemergency, the operator may obtain verbal approval to commence work. Withinfivedays after receivingverbal approval,the operator shall submit a Sundry Notice describing the work and acknowledging the verbal approval.
SUBSEQUENT REPORT - A subsequent report shall be submitted to the division within 30 days of the completion ofthe outlined work. Specific details of the work performed should be provided, including dates, well depths, placementof plugs, etc.
WELL ABANDONMENT - Proposals to abandon a well and subsequent reports of abandonment should include reasonsfor the abandonment; data on any former or present productive zones, or other zones with present significant fluidcontents not sealed off by cement or otherwise; depths (topand bottom) and method of placement of cement plugs;mud or other material placed below, between and above plugs; amount, size, and method of parting of any casing, liner,or tubingpulled and the depth to topof any left in the hole; method of closing top of well; and date well site conditionedfor final inspection looking to approval of the abandonment.
In addition to any Sundry Notice forms submitted, Form 8, Well Completion or Recompletion Report and Log mustbe submitted to the division to report the results of the followingoperations:• completing or plugging a new well,• reentering a previously plugged and abandoned well,• significantlydeepening an existing well bore below the current bottom-hole depth,e drilling horizontal laterals from an existing well bore,• drillinghydrocarbon exploratory holes such as core samples and stratigraphic tests,• recompleting to a different producing formation.
Send to:
Utah Divisionof Oil, Gas and Mining Phone: 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City, Utah 84114-5801
INSTRUCTIONS
This form shall be submitted by the operator to show the intention and/or completion of the following:e miscellaneous work projects and actions for which other specific report forms do not exist;e all other work and events as identified in section 11, Type of Action, or as required by the Utah Oil and Gas
Conservation General Rules, including:- minor deepening of an existing well bore,- plugging back a well,- recompleting to a different producing formation withinan existing well bore (intent only),- reperforating the current producing formation,- drillinga sidetrack to repair a well,- reporting monthly the status of each drillingwell.
This form is not to be used for nronosals to- drillnew wells,- reenter previously plugged and abandoned wells,- significantlydeepen existing wells below theircurrent bottom-hole depth,- drillhorizontal laterals from an existing well bore,- drill hydrocarbon exploratory holes such as core samples and stratigraphic tests.
Use Form 3, Application for Permit to Drill (APD) for such proposals.
NOTICE OF INTENT - A notice of intention to do work on a well or to change plans previously approved shall besubmitted in duplicate and must be received and approved by the divisionbefore the work is commenced. The operatoris responsible for receipt of the notice by the division in ample timefor proper considerationand action. In cases ofemergency, the operator may obtain verbal approval to commence work. Withinfivedays after receivingverbal approval,the operator shall submit a Sundry Notice describing the work and acknowledging the verbal approval.
SUBSEQUENT REPORT - A subsequent report shall be submitted to the division within 30 days of the completion ofthe outlined work. Specific details of the work performed should be provided, including dates, well depths, placementof plugs, etc.
WELL ABANDONMENT - Proposals to abandon a well and subsequent reports of abandonment should include reasonsfor the abandonment; data on any former or present productive zones, or other zones with present significant fluidcontents not sealed off by cement or otherwise; depths (topand bottom) and method of placement of cement plugs;mud or other material placed below, between and above plugs; amount, size, and method of parting of any casing, liner,or tubingpulled and the depth to topof any left in the hole; method of closing top of well; and date well site conditionedfor final inspection looking to approval of the abandonment.
In addition to any Sundry Notice forms submitted, Form 8, Well Completion or Recompletion Report and Log mustbe submitted to the division to report the results of the followingoperations:• completing or plugging a new well,• reentering a previously plugged and abandoned well,• significantlydeepening an existing well bore below the current bottom-hole depth,e drilling horizontal laterals from an existing well bore,• drillinghydrocarbon exploratory holes such as core samples and stratigraphic tests,• recompleting to a different producing formation.
Send to:
Utah Divisionof Oil, Gas and Mining Phone: 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City, Utah 84114-5801
INSTRUCTIONS
This form shall be submitted by the operator to show the intention and/or completion of the following:e miscellaneous work projects and actions for which other specific report forms do not exist;e all other work and events as identified in section 11, Type of Action, or as required by the Utah Oil and Gas
Conservation General Rules, including:- minor deepening of an existing well bore,- plugging back a well,- recompleting to a different producing formation withinan existing well bore (intent only),- reperforating the current producing formation,- drillinga sidetrack to repair a well,- reporting monthly the status of each drillingwell.
This form is not to be used for nronosals to- drillnew wells,- reenter previously plugged and abandoned wells,- significantlydeepen existing wells below theircurrent bottom-hole depth,- drillhorizontal laterals from an existing well bore,- drill hydrocarbon exploratory holes such as core samples and stratigraphic tests.
Use Form 3, Application for Permit to Drill (APD) for such proposals.
NOTICE OF INTENT - A notice of intention to do work on a well or to change plans previously approved shall besubmitted in duplicate and must be received and approved by the divisionbefore the work is commenced. The operatoris responsible for receipt of the notice by the division in ample timefor proper considerationand action. In cases ofemergency, the operator may obtain verbal approval to commence work. Withinfivedays after receivingverbal approval,the operator shall submit a Sundry Notice describing the work and acknowledging the verbal approval.
SUBSEQUENT REPORT - A subsequent report shall be submitted to the division within 30 days of the completion ofthe outlined work. Specific details of the work performed should be provided, including dates, well depths, placementof plugs, etc.
WELL ABANDONMENT - Proposals to abandon a well and subsequent reports of abandonment should include reasonsfor the abandonment; data on any former or present productive zones, or other zones with present significant fluidcontents not sealed off by cement or otherwise; depths (topand bottom) and method of placement of cement plugs;mud or other material placed below, between and above plugs; amount, size, and method of parting of any casing, liner,or tubingpulled and the depth to topof any left in the hole; method of closing top of well; and date well site conditionedfor final inspection looking to approval of the abandonment.
In addition to any Sundry Notice forms submitted, Form 8, Well Completion or Recompletion Report and Log mustbe submitted to the division to report the results of the followingoperations:• completing or plugging a new well,• reentering a previously plugged and abandoned well,• significantlydeepening an existing well bore below the current bottom-hole depth,e drilling horizontal laterals from an existing well bore,• drillinghydrocarbon exploratory holes such as core samples and stratigraphic tests,• recompleting to a different producing formation.
Send to:
Utah Divisionof Oil, Gas and Mining Phone: 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City, Utah 84114-5801
INSTRUCTIONS
This form shall be submitted by the operator to show the intention and/or completion of the following:e miscellaneous work projects and actions for which other specific report forms do not exist;e all other work and events as identified in section 11, Type of Action, or as required by the Utah Oil and Gas
Conservation General Rules, including:- minor deepening of an existing well bore,- plugging back a well,- recompleting to a different producing formation withinan existing well bore (intent only),- reperforating the current producing formation,- drillinga sidetrack to repair a well,- reporting monthly the status of each drillingwell.
This form is not to be used for nronosals to- drillnew wells,- reenter previously plugged and abandoned wells,- significantlydeepen existing wells below theircurrent bottom-hole depth,- drillhorizontal laterals from an existing well bore,- drill hydrocarbon exploratory holes such as core samples and stratigraphic tests.
Use Form 3, Application for Permit to Drill (APD) for such proposals.
NOTICE OF INTENT - A notice of intention to do work on a well or to change plans previously approved shall besubmitted in duplicate and must be received and approved by the divisionbefore the work is commenced. The operatoris responsible for receipt of the notice by the division in ample timefor proper considerationand action. In cases ofemergency, the operator may obtain verbal approval to commence work. Withinfivedays after receivingverbal approval,the operator shall submit a Sundry Notice describing the work and acknowledging the verbal approval.
SUBSEQUENT REPORT - A subsequent report shall be submitted to the division within 30 days of the completion ofthe outlined work. Specific details of the work performed should be provided, including dates, well depths, placementof plugs, etc.
WELL ABANDONMENT - Proposals to abandon a well and subsequent reports of abandonment should include reasonsfor the abandonment; data on any former or present productive zones, or other zones with present significant fluidcontents not sealed off by cement or otherwise; depths (topand bottom) and method of placement of cement plugs;mud or other material placed below, between and above plugs; amount, size, and method of parting of any casing, liner,or tubingpulled and the depth to topof any left in the hole; method of closing top of well; and date well site conditionedfor final inspection looking to approval of the abandonment.
In addition to any Sundry Notice forms submitted, Form 8, Well Completion or Recompletion Report and Log mustbe submitted to the division to report the results of the followingoperations:• completing or plugging a new well,• reentering a previously plugged and abandoned well,• significantlydeepening an existing well bore below the current bottom-hole depth,e drilling horizontal laterals from an existing well bore,• drillinghydrocarbon exploratory holes such as core samples and stratigraphic tests,• recompleting to a different producing formation.
Send to:
Utah Divisionof Oil, Gas and Mining Phone: 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City, Utah 84114-5801
INSTRUCTIONS
This form shall be submitted by the operator to show the intention and/or completion of the following:e miscellaneous work projects and actions for which other specific report forms do not exist;e all other work and events as identified in section 11, Type of Action, or as required by the Utah Oil and Gas
Conservation General Rules, including:- minor deepening of an existing well bore,- plugging back a well,- recompleting to a different producing formation withinan existing well bore (intent only),- reperforating the current producing formation,- drillinga sidetrack to repair a well,- reporting monthly the status of each drillingwell.
This form is not to be used for nronosals to- drillnew wells,- reenter previously plugged and abandoned wells,- significantlydeepen existing wells below theircurrent bottom-hole depth,- drillhorizontal laterals from an existing well bore,- drill hydrocarbon exploratory holes such as core samples and stratigraphic tests.
Use Form 3, Application for Permit to Drill (APD) for such proposals.
NOTICE OF INTENT - A notice of intention to do work on a well or to change plans previously approved shall besubmitted in duplicate and must be received and approved by the divisionbefore the work is commenced. The operatoris responsible for receipt of the notice by the division in ample timefor proper considerationand action. In cases ofemergency, the operator may obtain verbal approval to commence work. Withinfivedays after receivingverbal approval,the operator shall submit a Sundry Notice describing the work and acknowledging the verbal approval.
SUBSEQUENT REPORT - A subsequent report shall be submitted to the division within 30 days of the completion ofthe outlined work. Specific details of the work performed should be provided, including dates, well depths, placementof plugs, etc.
WELL ABANDONMENT - Proposals to abandon a well and subsequent reports of abandonment should include reasonsfor the abandonment; data on any former or present productive zones, or other zones with present significant fluidcontents not sealed off by cement or otherwise; depths (topand bottom) and method of placement of cement plugs;mud or other material placed below, between and above plugs; amount, size, and method of parting of any casing, liner,or tubingpulled and the depth to topof any left in the hole; method of closing top of well; and date well site conditionedfor final inspection looking to approval of the abandonment.
In addition to any Sundry Notice forms submitted, Form 8, Well Completion or Recompletion Report and Log mustbe submitted to the division to report the results of the followingoperations:• completing or plugging a new well,• reentering a previously plugged and abandoned well,• significantlydeepening an existing well bore below the current bottom-hole depth,e drilling horizontal laterals from an existing well bore,• drillinghydrocarbon exploratory holes such as core samples and stratigraphic tests,• recompleting to a different producing formation.
Send to:
Utah Divisionof Oil, Gas and Mining Phone: 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City, Utah 84114-5801
INSTRUCTIONS
This form shall be submitted by the operator to show the intention and/or completion of the following:e miscellaneous work projects and actions for which other specific report forms do not exist;e all other work and events as identified in section 11, Type of Action, or as required by the Utah Oil and Gas
Conservation General Rules, including:- minor deepening of an existing well bore,- plugging back a well,- recompleting to a different producing formation withinan existing well bore (intent only),- reperforating the current producing formation,- drillinga sidetrack to repair a well,- reporting monthly the status of each drillingwell.
This form is not to be used for nronosals to- drillnew wells,- reenter previously plugged and abandoned wells,- significantlydeepen existing wells below theircurrent bottom-hole depth,- drillhorizontal laterals from an existing well bore,- drill hydrocarbon exploratory holes such as core samples and stratigraphic tests.
Use Form 3, Application for Permit to Drill (APD) for such proposals.
NOTICE OF INTENT - A notice of intention to do work on a well or to change plans previously approved shall besubmitted in duplicate and must be received and approved by the divisionbefore the work is commenced. The operatoris responsible for receipt of the notice by the division in ample timefor proper considerationand action. In cases ofemergency, the operator may obtain verbal approval to commence work. Withinfivedays after receivingverbal approval,the operator shall submit a Sundry Notice describing the work and acknowledging the verbal approval.
SUBSEQUENT REPORT - A subsequent report shall be submitted to the division within 30 days of the completion ofthe outlined work. Specific details of the work performed should be provided, including dates, well depths, placementof plugs, etc.
WELL ABANDONMENT - Proposals to abandon a well and subsequent reports of abandonment should include reasonsfor the abandonment; data on any former or present productive zones, or other zones with present significant fluidcontents not sealed off by cement or otherwise; depths (topand bottom) and method of placement of cement plugs;mud or other material placed below, between and above plugs; amount, size, and method of parting of any casing, liner,or tubingpulled and the depth to topof any left in the hole; method of closing top of well; and date well site conditionedfor final inspection looking to approval of the abandonment.
In addition to any Sundry Notice forms submitted, Form 8, Well Completion or Recompletion Report and Log mustbe submitted to the division to report the results of the followingoperations:• completing or plugging a new well,• reentering a previously plugged and abandoned well,• significantlydeepening an existing well bore below the current bottom-hole depth,e drilling horizontal laterals from an existing well bore,• drillinghydrocarbon exploratory holes such as core samples and stratigraphic tests,• recompleting to a different producing formation.
Send to:
Utah Divisionof Oil, Gas and Mining Phone: 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City, Utah 84114-5801
INSTRUCTIONS
This form shall be submitted by the operator to show the intention and/or completion of the following:e miscellaneous work projects and actions for which other specific report forms do not exist;e all other work and events as identified in section 11, Type of Action, or as required by the Utah Oil and Gas
Conservation General Rules, including:- minor deepening of an existing well bore,- plugging back a well,- recompleting to a different producing formation withinan existing well bore (intent only),- reperforating the current producing formation,- drillinga sidetrack to repair a well,- reporting monthly the status of each drillingwell.
This form is not to be used for nronosals to- drillnew wells,- reenter previously plugged and abandoned wells,- significantlydeepen existing wells below theircurrent bottom-hole depth,- drillhorizontal laterals from an existing well bore,- drill hydrocarbon exploratory holes such as core samples and stratigraphic tests.
Use Form 3, Application for Permit to Drill (APD) for such proposals.
NOTICE OF INTENT - A notice of intention to do work on a well or to change plans previously approved shall besubmitted in duplicate and must be received and approved by the divisionbefore the work is commenced. The operatoris responsible for receipt of the notice by the division in ample time for proper consideration and action. In cases ofemergency, the operator may obtain verbal approval to commence work. Withinfivedays after receivingverbal approval,the operator shall submit a Sundry Notice describing the work and acknowledging the verbal approval.
SUBSEQUENT REPORT - A subsequent report shall be submitted to the division within 30 days of the completion ofthe outlined work. Specific details of the work performed should be provided, including dates, well depths, placementof plugs, etc.
WELL ABANDONMENT - Proposals to abandon a well and subsequent reports of abandonment should include reasonsfor the abandonment; data on any former or present productive zones, or other zones with present significant fluidcontents not sealed off by cement or otherwise; depths (topand bottom) and method of placement of cement plugs;mud or other material placed below, between and above plugs; amount, size, and method of parting of any casing, liner,or tubingpulled and the depth to topof any left in the hole; method of closing top of well; and date well site conditionedfor final inspection looking to approval of the abandonment.
In addition to any Sundry Notice forms submitted, Form 8, Well Completion or Recompletion Report and Log mustbe submitted to the division to report the results of the followingoperations:• completing or plugging a new well,• reentering a previously plugged and abandoned well,• significantlydeepening an existing well bore below the current bottom-hole depth,e drilling horizontal laterals from an existing well bore,• drillinghydrocarbon exploratory holes such as core samples and stratigraphic tests,• recompleting to a different producing formation.
Send to:
Utah Divisionof Oil, Gas and Mining Phone: 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City, Utah 84114-5801
INSTRUCTIONS
This form shall be submitted by the operator to show the intention and/or completion of the following:e miscellaneous work projects and actions for which other specific report forms do not exist;e all other work and events as identified in section 11, Type of Action, or as required by the Utah Oil and Gas
Conservation General Rules, including:- minor deepening of an existing well bore,- plugging back a well,- recompleting to a different producing formation withinan existing well bore (intent only),- reperforating the current producing formation,- drillinga sidetrack to repair a well,- reporting monthly the status of each drillingwell.
This form is not to be used for nronosals to- drillnew wells,- reenter previously plugged and abandoned wells,- significantlydeepen existing wells below theircurrent bottom-hole depth,- drillhorizontal laterals from an existing well bore,- drill hydrocarbon exploratory holes such as core samples and stratigraphic tests.
Use Form 3, Application for Permit to Drill (APD) for such proposals.
NOTICE OF INTENT - A notice of intention to do work on a well or to change plans previously approved shall besubmitted in duplicate and must be received and approved by the divisionbefore the work is commenced. The operatoris responsible for receipt of the notice by the division in ample time for proper consideration and action. In cases ofemergency, the operator may obtain verbal approval to commence work. Withinfivedays after receivingverbal approval,the operator shall submit a Sundry Notice describing the work and acknowledging the verbal approval.
SUBSEQUENT REPORT - A subsequent report shall be submitted to the division within 30 days of the completion ofthe outlined work. Specific details of the work performed should be provided, including dates, well depths, placementof plugs, etc.
WELL ABANDONMENT - Proposals to abandon a well and subsequent reports of abandonment should include reasonsfor the abandonment; data on any former or present productive zones, or other zones with present significant fluidcontents not sealed off by cement or otherwise; depths (topand bottom) and method of placement of cement plugs;mud or other material placed below, between and above plugs; amount, size, and method of parting of any casing, liner,or tubingpulled and the depth to topof any left in the hole; method of closing top of well; and date well site conditionedfor final inspection looking to approval of the abandonment.
In addition to any Sundry Notice forms submitted, Form 8, Well Completion or Recompletion Report and Log mustbe submitted to the division to report the results of the followingoperations:• completing or plugging a new well,• reentering a previously plugged and abandoned well,• significantlydeepening an existing well bore below the current bottom-hole depth,e drilling horizontal laterals from an existing well bore,• drillinghydrocarbon exploratory holes such as core samples and stratigraphic tests,• recompleting to a different producing formation.
Send to:
Utah Divisionof Oil, Gas and Mining Phone: 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City, Utah 84114-5801
INSTRUCTIONS
This form shall be submitted by the operator to show the intention and/or completion of the following:e miscellaneous work projects and actions for which other specific report forms do not exist;e all other work and events as identified in section 11, Type of Action, or as required by the Utah Oil and Gas
Conservation General Rules, including:- minor deepening of an existing well bore,- plugging back a well,- recompleting to a different producing formation withinan existing well bore (intent only),- reperforating the current producing formation,- drillinga sidetrack to repair a well,- reporting monthly the status of each drillingwell.
This form is not to be used for nronosals to- drillnew wells,- reenter previously plugged and abandoned wells,- significantlydeepen existing wells below theircurrent bottom-hole depth,- drillhorizontal laterals from an existing well bore,- drill hydrocarbon exploratory holes such as core samples and stratigraphic tests.
Use Form 3, Application for Permit to Drill (APD) for such proposals.
NOTICE OF INTENT - A notice of intention to do work on a well or to change plans previously approved shall besubmitted in duplicate and must be received and approved by the divisionbefore the work is commenced. The operatoris responsible for receipt of the notice by the division in ample time for proper consideration and action. In cases ofemergency, the operator may obtain verbal approval to commence work. Withinfivedays after receivingverbal approval,the operator shall submit a Sundry Notice describing the work and acknowledging the verbal approval.
SUBSEQUENT REPORT - A subsequent report shall be submitted to the division within 30 days of the completion ofthe outlined work. Specific details of the work performed should be provided, including dates, well depths, placementof plugs, etc.
WELL ABANDONMENT - Proposals to abandon a well and subsequent reports of abandonment should include reasonsfor the abandonment; data on any former or present productive zones, or other zones with present significant fluidcontents not sealed off by cement or otherwise; depths (topand bottom) and method of placement of cement plugs;mud or other material placed below, between and above plugs; amount, size, and method of parting of any casing, liner,or tubingpulled and the depth to topof any left in the hole; method of closing top of well; and date well site conditionedfor final inspection looking to approval of the abandonment.
In addition to any Sundry Notice forms submitted, Form 8, Well Completion or Recompletion Report and Log mustbe submitted to the division to report the results of the followingoperations:• completing or plugging a new well,• reentering a previously plugged and abandoned well,• significantlydeepening an existing well bore below the current bottom-hole depth,e drilling horizontal laterals from an existing well bore,• drillinghydrocarbon exploratory holes such as core samples and stratigraphic tests,• recompleting to a different producing formation.
Send to:
Utah Divisionof Oil, Gas and Mining Phone: 801-538-53401594 West North Temple, Suite 1210Box 145801 Fax: 801-359-3940Salt Lake City, Utah 84114-5801
Services;
Production Management Measurement, Analytical, Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O.
BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORT
LOCATION NO. 100 COUNTY GRAND STATE UTAH DATE 3/23/2015 STATION OR FEDERAL 1-4 RTU ADDRESS 100 RTU GROUP I 21 FEDERAL I UTU87659 API 430-195-002-90000 CUSTOMER LEASE #
GPS LOCATION LATITUDE N 3911. 221'.0" LOGITUDE W 1098.858" I ELEVATION 4955 LEAK OK I PASSED X I NOT PASSED I REPAIRED I NOT REPAIRED TIME OF TEST 11:00 AM TEST
TRANSDUCER WEATHERFORD CIM MVT FLOW 0 SERIAL # S7138083JNC TYPE COMPUTER
CALIBRATION EQUIP MODEl#, II CRYSTAL MODEL IS33 36/3000psi, SERIAL TEMP
THERMOPROBE MODEL TL-1W, SERIAL 1-RTD
PIE, MODEL211, SERIAL 110010, SERIAL# RECAllS DATE PRESS 2262-145413, DUE 7-21·15 9719, DUE 7-22-15 DUE 7-23-15
DIFFERENTIAL TEST STATIC TEST ANALOG 0 RANGE 0-400 ZERO UNDER
-0.01 ZERO AT ATMOS
0.00 ANALOG 1 RANGE 0-1500 BASE 14.73 ATMOS 12.36 PRESSURE PRESSURE PRESS PRESS
LIVE DIFFERENTIIAL FOUND 2.51 LIVE DIFFERENTIIAL LEFT 69.30 LIVE STATIC PRESS FOUND 60.30 LIVE STATIC PRESS LEFT 66.30
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0 0 0.06 -0.01% 0
200 200.21 -0.05% 200 250 250.64 -0.13% 250
400 400.73 -0.18% 400 500 500.39 -0.08% 500
ORIFICE PLATE TEMPERATURE TEST SIZE 2 X 0.750 BETA RATIO 0.375 ANALOG 3 RANGE 0-150
PLATE DIRTY SMALL NICK Do not drive RTD if fiowing temp. is + or- 0.5 degrees of test thermometer CONDITION
EDGES YES SEAL RING GOOD AS FOUND AS LEFT SHARP? CONDITION
BEVELED YES BEVEL DOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER PLATE? STREAM?
STAMPED OR 0.750 MEASURED SIZE MIC SIZE NA #DIV/Ol
ORIFICE FITTING #DIV/Ol
SIZE 2.067 I TYPE DANIEL STATIC TAP US #DIV/Ol
SERIAL # 13180234 METER 2.067 LINE TEMPERATURE TUBE ID
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 66.8 66.8 Same Same
Calibrate meter update onsite meter card and process calibration report Changed orifice plate from a .750 to a 6.25. filled out an orifice plate change report.
TECHNICIAN SIGNATURE $_li.g~
WITNESS NOTIFICATION REVIEW
COMPANY BLM CONTACT Phone REVIEWED BY Jok.e.~ METHOD
CONTACT Jeff BrownlLee Oliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE J,; £B~/.f- e~ NITNESS DATE 3/23/2015
Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'u^S'TONORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659APl430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AM
TRANSDUCER WEATHERFORD CIM MVT coiPOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL 1- PIE, MODEL211, SERIAL 110010,SERIAL# RECALIB DATE PRESS 2262-145413, DUE 7-21-15 TEMP 9719, DUE 7-22-15 RTD DUE 7-23-15
DIFFERENTIALTIÉST STATIC TESTANALOG 0 RANGE 0-400 isROSUNDRER
-0.01
ZERO ASSATMOS 0.00 ANALOG RANGE 0-1500 ,"A"sES 14.73 72° 12.36
LIVEDIFFERENTIIALFOUND 2.51 LIVEDIFFERENTIIALLEFT 69.30 LIVESTATIC PRESS FOUND 60.30 LIVESTATIC PRESS LEFT 66.30
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0 0 0.06 -0.01% 0
200 200.21 -0.05% 200 250 250.64 -0.13% 250
400 400.73 -0.18% 400 500 500.39 -0.08% 500
ORIFICE PLATE TEMPERATURE TESTS1ZE 2 X 0.750 BETARATIO 0.375 ANALOG 3 RANGE 0-150
CONTEON DIRTY SMALL NICK Do not drive RTD if t1owinqtemp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coEANLDlRINGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.750 MlCSIZE NA #DIV/0!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!SERIAL# 13180234 ,METEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 66.8 66.8 Same SameCalibrate meter update onsite meter card and process calit ration report. Changed orifice plate from a .750 to a 6.25.filled out an orifice plate change report.
TECHNICIANSIGNATURE OgWITNESS NOTIFICATION REVIEW
COMPANY BLM coNTHAOCD' Phone REVIEWED BY
CONTACT Jeff BrOwn/LeeOliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE,
€0904 ITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'u^S'TONORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659APl430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AM
TRANSDUCER WEATHERFORD CIM MVT coiPOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL 1- PIE, MODEL211, SERIAL 110010,SERIAL# RECALIB DATE PRESS 2262-145413, DUE 7-21-15 TEMP 9719, DUE 7-22-15 RTD DUE 7-23-15
DIFFERENTIALTIÉST STATIC TESTANALOG 0 RANGE 0-400 isROSUNDRER
-0.01
ZERO ASSATMOS 0.00 ANALOG RANGE 0-1500 ,"A"sES 14.73 72° 12.36
LIVEDIFFERENTIIALFOUND 2.51 LIVEDIFFERENTIIALLEFT 69.30 LIVESTATIC PRESS FOUND 60.30 LIVESTATIC PRESS LEFT 66.30
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0 0 0.06 -0.01% 0
200 200.21 -0.05% 200 250 250.64 -0.13% 250
400 400.73 -0.18% 400 500 500.39 -0.08% 500
ORIFICE PLATE TEMPERATURE TESTS1ZE 2 X 0.750 BETARATIO 0.375 ANALOG 3 RANGE 0-150
CONTEON DIRTY SMALL NICK Do not drive RTD if t1owinqtemp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coEANLDlRINGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.750 MlCSIZE NA #DIV/0!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!SERIAL# 13180234 ,METEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 66.8 66.8 Same SameCalibrate meter update onsite meter card and process calit ration report. Changed orifice plate from a .750 to a 6.25.filled out an orifice plate change report.
TECHNICIANSIGNATURE OgWITNESS NOTIFICATION REVIEW
COMPANY BLM coNTHAOCD' Phone REVIEWED BY
CONTACT Jeff BrOwn/LeeOliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE,
€0904 ITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'u^S'TONORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659APl430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AM
TRANSDUCER WEATHERFORD CIM MVT coiPOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL 1- PIE, MODEL211, SERIAL 110010,SERIAL# RECALIB DATE PRESS 2262-145413, DUE 7-21-15 TEMP 9719, DUE 7-22-15 RTD DUE 7-23-15
DIFFERENTIALTIÉST STATIC TESTANALOG 0 RANGE 0-400 isROSUNDRER
-0.01
ZERO ASSATMOS 0.00 ANALOG RANGE 0-1500 ,"A"sES 14.73 72° 12.36
LIVEDIFFERENTIIALFOUND 2.51 LIVEDIFFERENTIIALLEFT 69.30 LIVESTATIC PRESS FOUND 60.30 LIVESTATIC PRESS LEFT 66.30
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0 0 0.06 -0.01% 0
200 200.21 -0.05% 200 250 250.64 -0.13% 250
400 400.73 -0.18% 400 500 500.39 -0.08% 500
ORIFICE PLATE TEMPERATURE TESTS1ZE 2 X 0.750 BETARATIO 0.375 ANALOG 3 RANGE 0-150
CONTEON DIRTY SMALL NICK Do not drive RTD if t1owinqtemp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coEANLDlRINGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.750 MlCSIZE NA #DIV/0!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!SERIAL# 13180234 ,METEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 66.8 66.8 Same SameCalibrate meter update onsite meter card and process calit ration report. Changed orifice plate from a .750 to a 6.25.filled out an orifice plate change report.
TECHNICIANSIGNATURE OgWITNESS NOTIFICATION REVIEW
COMPANY BLM coNTHAOCD' Phone REVIEWED BY
CONTACT Jeff BrOwn/LeeOliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE,
€0904 ITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'u^S'TONORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659APl430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AM
TRANSDUCER WEATHERFORD CIM MVT coiPOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL 1- PIE, MODEL211, SERIAL 110010,SERIAL# RECALIB DATE PRESS 2262-145413, DUE 7-21-15 TEMP 9719, DUE 7-22-15 RTD DUE 7-23-15
DIFFERENTIALTIÉST STATIC TESTANALOG 0 RANGE 0-400 isROSUNDRER
-0.01
ZERO ASSATMOS 0.00 ANALOG RANGE 0-1500 ,"A"sES 14.73 72° 12.36
LIVEDIFFERENTIIALFOUND 2.51 LIVEDIFFERENTIIALLEFT 69.30 LIVESTATIC PRESS FOUND 60.30 LIVESTATIC PRESS LEFT 66.30
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0 0 0.06 -0.01% 0
200 200.21 -0.05% 200 250 250.64 -0.13% 250
400 400.73 -0.18% 400 500 500.39 -0.08% 500
ORIFICE PLATE TEMPERATURE TESTS1ZE 2 X 0.750 BETARATIO 0.375 ANALOG 3 RANGE 0-150
CONTEON DIRTY SMALL NICK Do not drive RTD if t1owinqtemp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coEANLDlRINGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.750 MlCSIZE NA #DIV/0!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!SERIAL# 13180234 ,METEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 66.8 66.8 Same SameCalibrate meter update onsite meter card and process calit ration report. Changed orifice plate from a .750 to a 6.25.filled out an orifice plate change report.
TECHNICIANSIGNATURE OgWITNESS NOTIFICATION REVIEW
COMPANY BLM coNTHAOCD' Phone REVIEWED BY
CONTACT Jeff BrOwn/LeeOliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE,
€0904 ITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'u^S'TONORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659APl430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AM
TRANSDUCER WEATHERFORD CIM MVT coiPOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL 1- PIE, MODEL211, SERIAL 110010,SERIAL# RECALIB DATE PRESS 2262-145413, DUE 7-21-15 TEMP 9719, DUE 7-22-15 RTD DUE 7-23-15
DIFFERENTIALTIÉST STATIC TESTANALOG 0 RANGE 0-400 isROSUNDRER
-0.01
ZERO ASSATMOS 0.00 ANALOG RANGE 0-1500 ,"A"sES 14.73 72° 12.36
LIVEDIFFERENTIIALFOUND 2.51 LIVEDIFFERENTIIALLEFT 69.30 LIVESTATIC PRESS FOUND 60.30 LIVESTATIC PRESS LEFT 66.30
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0 0 0.06 -0.01% 0
200 200.21 -0.05% 200 250 250.64 -0.13% 250
400 400.73 -0.18% 400 500 500.39 -0.08% 500
ORIFICE PLATE TEMPERATURE TESTS1ZE 2 X 0.750 BETARATIO 0.375 ANALOG 3 RANGE 0-150
CONTEON DIRTY SMALL NICK Do not drive RTD if t1owinqtemp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coEANLDlRINGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.750 MlCSIZE NA #DIV/0!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!SERIAL# 13180234 ,METEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 66.8 66.8 Same SameCalibrate meter update onsite meter card and process calit ration report. Changed orifice plate from a .750 to a 6.25.filled out an orifice plate change report.
TECHNICIANSIGNATURE OgWITNESS NOTIFICATION REVIEW
COMPANY BLM coNTHAOCD' Phone REVIEWED BY
CONTACT Jeff BrOwn/LeeOliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE,
€0904 ITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'u^S'TONORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659APl430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AM
TRANSDUCER WEATHERFORD CIM MVT coiPOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL 1- PIE, MODEL211, SERIAL 110010,SERIAL# RECALIB DATE PRESS 2262-145413, DUE 7-21-15 TEMP 9719, DUE 7-22-15 RTD DUE 7-23-15
DIFFERENTIALTIÉST STATIC TESTANALOG 0 RANGE 0-400 isROSUNDRER
-0.01
ZERO ASSATMOS 0.00 ANALOG RANGE 0-1500 ,"A"sES 14.73 72° 12.36
LIVEDIFFERENTIIALFOUND 2.51 LIVEDIFFERENTIIALLEFT 69.30 LIVESTATIC PRESS FOUND 60.30 LIVESTATIC PRESS LEFT 66.30
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0 0 0.06 -0.01% 0
200 200.21 -0.05% 200 250 250.64 -0.13% 250
400 400.73 -0.18% 400 500 500.39 -0.08% 500
ORIFICE PLATE TEMPERATURE TESTS1ZE 2 X 0.750 BETARATIO 0.375 ANALOG 3 RANGE 0-150
CONTEON DIRTY SMALL NICK Do not drive RTD if t1owinqtemp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coEANLDlRINGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.750 MlCSIZE NA #DIV/0!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!SERIAL# 13180234 ,METEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 66.8 66.8 Same SameCalibrate meter update onsite meter card and process calit ration report. Changed orifice plate from a .750 to a 6.25.filled out an orifice plate change report.
TECHNICIANSIGNATURE OgWITNESS NOTIFICATION REVIEW
COMPANY BLM coNTHAOCD' Phone REVIEWED BY
CONTACT Jeff BrOwn/LeeOliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE,
€0904 ITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'u^S'TONORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659APl430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AM
TRANSDUCER WEATHERFORD CIM MVT coiPOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL 1- PIE, MODEL211, SERIAL 110010,SERIAL# RECALIB DATE PRESS 2262-145413, DUE 7-21-15 TEMP 9719, DUE 7-22-15 RTD DUE 7-23-15
DIFFERENTIALTIÉST STATIC TESTANALOG 0 RANGE 0-400 isROSUNDRER
-0.01
ZERO ASSATMOS 0.00 ANALOG RANGE 0-1500 ,"A"sES 14.73 72° 12.36
LIVEDIFFERENTIIALFOUND 2.51 LIVEDIFFERENTIIALLEFT 69.30 LIVESTATIC PRESS FOUND 60.30 LIVESTATIC PRESS LEFT 66.30
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0 0 0.06 -0.01% 0
200 200.21 -0.05% 200 250 250.64 -0.13% 250
400 400.73 -0.18% 400 500 500.39 -0.08% 500
ORIFICE PLATE TEMPERATURE TESTS1ZE 2 X 0.750 BETARATIO 0.375 ANALOG 3 RANGE 0-150
CONTEON DIRTY SMALL NICK Do not drive RTD if t1owinqtemp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coEANLDlRINGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.750 MlCSIZE NA #DIV/0!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!SERIAL# 13180234 ,METEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 66.8 66.8 Same SameCalibrate meter update onsite meter card and process calit ration report. Changed orifice plate from a .750 to a 6.25.filled out an orifice plate change report.
TECHNICIANSIGNATURE OgWITNESS NOTIFICATION REVIEW
COMPANY BLM coNTHAOCD' Phone REVIEWED BY
CONTACT Jeff BrOwn/LeeOliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE,
€0904 ITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'u^S'TONORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659APl430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AM
TRANSDUCER WEATHERFORD CIM MVT coiPOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL 1- PIE, MODEL211, SERIAL 110010,SERIAL# RECALIB DATE PRESS 2262-145413, DUE 7-21-15 TEMP 9719, DUE 7-22-15 RTD DUE 7-23-15
DIFFERENTIALTIÉST STATIC TESTANALOG 0 RANGE 0-400 isROSUNDRER
-0.01
ZERO ASSATMOS 0.00 ANALOG RANGE 0-1500 ,"A"sES 14.73 72° 12.36
LIVEDIFFERENTIIALFOUND 2.51 LIVEDIFFERENTIIALLEFT 69.30 LIVESTATIC PRESS FOUND 60.30 LIVESTATIC PRESS LEFT 66.30
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0 0 0.06 -0.01% 0
200 200.21 -0.05% 200 250 250.64 -0.13% 250
400 400.73 -0.18% 400 500 500.39 -0.08% 500
ORIFICE PLATE TEMPERATURE TESTS1ZE 2 X 0.750 BETARATIO 0.375 ANALOG 3 RANGE 0-150
CONTEON DIRTY SMALL NICK Do not drive RTD if t1owinqtemp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coEANLDlRINGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.750 MlCSIZE NA #DIV/0!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!SERIAL# 13180234 ,METEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 66.8 66.8 Same SameCalibrate meter update onsite meter card and process calit ration report. Changed orifice plate from a .750 to a 6.25.filled out an orifice plate change report.
TECHNICIANSIGNATURE OgWITNESS NOTIFICATION REVIEW
COMPANY BLM coNTHAOCD' Phone REVIEWED BY
CONTACT Jeff BrOwn/LeeOliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE,
€0904 ITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'u^S'TONORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659APl430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AM
TRANSDUCER WEATHERFORD CIM MVT coiPOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL 1- PIE, MODEL211, SERIAL 110010,SERIAL# RECALIB DATE PRESS 2262-145413, DUE 7-21-15 TEMP 9719, DUE 7-22-15 RTD DUE 7-23-15
DIFFERENTIALTIÉST STATIC TESTANALOG 0 RANGE 0-400 isROSUNDRER
-0.01
ZERO ASSATMOS 0.00 ANALOG RANGE 0-1500 ,"A"sES 14.73 72° 12.36
LIVEDIFFERENTIIALFOUND 2.51 LIVEDIFFERENTIIALLEFT 69.30 LIVESTATIC PRESS FOUND 60.30 LIVESTATIC PRESS LEFT 66.30
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0 0 0.06 -0.01% 0
200 200.21 -0.05% 200 250 250.64 -0.13% 250
400 400.73 -0.18% 400 500 500.39 -0.08% 500
ORIFICE PLATE TEMPERATURE TESTS1ZE 2 X 0.750 BETARATIO 0.375 ANALOG 3 RANGE 0-150
CONTEON DIRTY SMALL NICK Do not drive RTD if t1owinqtemp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coEANLDlRINGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.750 MlCSIZE NA #DIV/0!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!SERIAL# 13180234 ,METEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 66.8 66.8 Same SameCalibrate meter update onsite meter card and process calit ration report. Changed orifice plate from a .750 to a 6.25.filled out an orifice plate change report.
TECHNICIANSIGNATURE OgWITNESS NOTIFICATION REVIEW
COMPANY BLM coNTHAOCD' Phone REVIEWED BY
CONTACT Jeff BrOwn/LeeOliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE,
€0904 ITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'u^S'TONORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659APl430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AM
TRANSDUCER WEATHERFORD CIM MVT coiPOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL 1- PIE, MODEL211, SERIAL 110010,SERIAL# RECALIB DATE PRESS 2262-145413, DUE 7-21-15 TEMP 9719, DUE 7-22-15 RTD DUE 7-23-15
DIFFERENTIALTIÉST STATIC TESTANALOG 0 RANGE 0-400 isROSUNDRER
-0.01
ZERO ASSATMOS 0.00 ANALOG RANGE 0-1500 ,"A"sES 14.73 72° 12.36
LIVEDIFFERENTIIALFOUND 2.51 LIVEDIFFERENTIIALLEFT 69.30 LIVESTATIC PRESS FOUND 60.30 LIVESTATIC PRESS LEFT 66.30
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0 0 0.06 -0.01% 0
200 200.21 -0.05% 200 250 250.64 -0.13% 250
400 400.73 -0.18% 400 500 500.39 -0.08% 500
ORIFICE PLATE TEMPERATURE TESTS1ZE 2 X 0.750 BETARATIO 0.375 ANALOG 3 RANGE 0-150
CONTEON DIRTY SMALL NICK Do not drive RTD if t1owinqtemp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coEANLDlRINGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.750 MlCSIZE NA #DIV/0!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!SERIAL# 13180234 ,METEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 66.8 66.8 Same SameCalibrate meter update onsite meter card and process calit ration report. Changed orifice plate from a .750 to a 6.25.filled out an orifice plate change report.
TECHNICIANSIGNATURE OgWITNESS NOTIFICATION REVIEW
COMPANY BLM coNTHAOCD' Phone REVIEWED BY
CONTACT Jeff BrOwn/LeeOliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE,
€0904 ITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'u^S'TONORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659APl430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AM
TRANSDUCER WEATHERFORD CIM MVT coiPOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL 1- PIE, MODEL211, SERIAL 110010,SERIAL# RECALIB DATE PRESS 2262-145413, DUE 7-21-15 TEMP 9719, DUE 7-22-15 RTD DUE 7-23-15
DIFFERENTIALTIÉST STATIC TESTANALOG 0 RANGE 0-400 isROSUNDRER
-0.01
ZERO ASSATMOS 0.00 ANALOG RANGE 0-1500 ,"A"sES 14.73 72° 12.36
LIVEDIFFERENTIIALFOUND 2.51 LIVEDIFFERENTIIALLEFT 69.30 LIVESTATIC PRESS FOUND 60.30 LIVESTATIC PRESS LEFT 66.30
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0 0 0.06 -0.01% 0
200 200.21 -0.05% 200 250 250.64 -0.13% 250
400 400.73 -0.18% 400 500 500.39 -0.08% 500
ORIFICE PLATE TEMPERATURE TESTS1ZE 2 X 0.750 BETARATIO 0.375 ANALOG 3 RANGE 0-150
CONTEON DIRTY SMALL NICK Do not drive RTD if t1owinqtemp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coEANLDlRINGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
ifEDOR 0.750 MlCSIZE NA #DIV/0!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!SERIAL# 13180234 ,METEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 66.8 66.8 Same SameCalibrate meter update onsite meter card and process calit ration report. Changed orifice plate from a .750 to a 6.25.filled out an orifice plate change report.
TECHNICIANSIGNATURE OgWITNESS NOTIFICATION REVIEW
COMPANY BLM coNTHAOCD' Phone REVIEWED BY
CONTACT Jeff BrOwn/LeeOliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE,
€0904 ITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'u^S'TONORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659APl430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AM
TRANSDUCER WEATHERFORD CIM MVT coiPOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL 1- PIE, MODEL211, SERIAL 110010,SERIAL# RECALIB DATE PRESS 2262-145413, DUE 7-21-15 TEMP 9719, DUE 7-22-15 RTD DUE 7-23-15
DIFFERENTIALTIÉST STATIC TESTANALOG 0 RANGE 0-400 isROSUNDRER
-0.01
ZERO ASSATMOS 0.00 ANALOG RANGE 0-1500 ,"A"sES 14.73 72° 12.36
LIVEDIFFERENTIIALFOUND 2.51 LIVEDIFFERENTIIALLEFT 69.30 LIVESTATIC PRESS FOUND 60.30 LIVESTATIC PRESS LEFT 66.30
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0 0 0.06 -0.01% 0
200 200.21 -0.05% 200 250 250.64 -0.13% 250
400 400.73 -0.18% 400 500 500.39 -0.08% 500
ORIFICE PLATE TEMPERATURE TESTS1ZE 2 X 0.750 BETARATIO 0.375 ANALOG 3 RANGE 0-150
CONTEON DIRTY SMALL NICK Do not drive RTD if t1owinqtemp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coEANLDlRINGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
ifEDOR 0.750 MlCSIZE NA #DIV/0!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!SERIAL# 13180234 ,METEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 66.8 66.8 Same SameCalibrate meter update onsite meter card and process calit ration report. Changed orifice plate from a .750 to a 6.25.filled out an orifice plate change report.
TECHNICIANSIGNATURE OgWITNESS NOTIFICATION REVIEW
COMPANY BLM coNTHAOCD' Phone REVIEWED BY
CONTACT Jeff BrOwn/LeeOliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE,
€0904 ITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'u^S'TONORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659APl430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AM
TRANSDUCER WEATHERFORD CIM MVT coiPOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL 1- PIE, MODEL211, SERIAL 110010,SERIAL# RECALIB DATE PRESS 2262-145413, DUE 7-21-15 TEMP 9719, DUE 7-22-15 RTD DUE 7-23-15
DIFFERENTIALTIÉST STATIC TESTANALOG 0 RANGE 0-400 isROSUNDRER
-0.01
ZERO ASSATMOS 0.00 ANALOG RANGE 0-1500 ,"A"sES 14.73 72° 12.36
LIVEDIFFERENTIIALFOUND 2.51 LIVEDIFFERENTIIALLEFT 69.30 LIVESTATIC PRESS FOUND 60.30 LIVESTATIC PRESS LEFT 66.30
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0 0 0.06 -0.01% 0
200 200.21 -0.05% 200 250 250.64 -0.13% 250
400 400.73 -0.18% 400 500 500.39 -0.08% 500
ORIFICE PLATE TEMPERATURE TESTS1ZE 2 X 0.750 BETARATIO 0.375 ANALOG 3 RANGE 0-150
CONTEON DIRTY SMALL NICK Do not drive RTD if t1owinqtemp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coEANLDlRINGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
ifEDOR 0.750 MlCSIZE NA #DIV/0!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!SERIAL# 13180234 ,METEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 66.8 66.8 Same SameCalibrate meter update onsite meter card and process calit ration report. Changed orifice plate from a .750 to a 6.25.filled out an orifice plate change report.
TECHNICIANSIGNATURE OgWITNESS NOTIFICATION REVIEW
COMPANY BLM coNTHAOCD' Phone REVIEWED BY
CONTACT Jeff BrOwn/LeeOliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE,
€0904 ITNESS DATE
LOCATION NO.
STATION OR CUSTOMER
LEAK TEST
TRANSDUCER TYPE
SIZE
STAMPED OR MEASURED SIZE
SIZE
SERIAL #
OK
2
l' Services ",- ~
Production Management Measurement, Analytical, Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ORIFICE PLATE CHANGE REPORT 100 COUNTY DATE 3/23/2015
FEDERAL 1-4 UTU87659 API 430-195-002-90000
PASSED X 8:38 AM
SERIAL # S7138083JNC
DIFFERENTIAL STATIC o RANGE RANGE 0-1500
TEMPERATURE BASE PRESSURE 14.73
0-150 ATMOSPHERIC PRESSURE 12.36
2.51 INCHES H20
ORIFICE P
x 0.750 BETA RATIO 0.375 SIZE 2.000 x 0.625 BETA RATIO 0.3125
DIRTY SMALL NICK
Good GOOD
YES YES
NA NC
STATIC TAP US TAPS SAME
2.067 SAME
REMARKS
5
Jeff Brown/Lee Oliver 3/19/2015 DATE
3/23/2015
Production ManagementMeasurement, Analytical,Automation, Well Testing
Services Office:970-245-2490 Fax:970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ORIFICE PLATE CHANGE REPORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'uAST NORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAERA, UTU87659APl430-195-002-90000
EE OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 8:38 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNC
DIFFERENTIAL STATICANA OG 0 RANGE 0-400 ANA OG 1 RANGE 0-1500
TEMPERATURE BASE PRESSURE 14.73AMNAOEG, 2 RANGE 0-150 ATMOSPHERIC PRESSURE 12.36
DIFFERENTIAL PRESSURE BEFOR PLATE CHANGE 2.51 INCHES H2O DIFFERENTIAL PRESSURE AFTER PLATE CHANGE 69.3 INCHES H2O
ORIFICE PLATEREMOVED ORIFICE PLATE INSTALLEDSIZE 2 X 0.750 BETA RATIO 0.375 SIZE 2.000 X 0.625 BETA RATIO 0.3125
CON TON DIRTYSMALL NICK CON TON NEWsEDGRES, YES coiDIRINOGN Good sEDGREs, YES coiDRINOGN GOOD
BEVELED YES BEVELDOWN YES BEVELED YES BEVELDOWN YESPLATE? STREAM? PLATE? STREAM?
DRED OR 0.750 MICSIZE NA 27ED OR 0.625 MICSIZE NC
ORIFICE FITTING ORIFICE FITTINGSIZE 2.067 TYPE DANIEL STATICTAP US SIZE SAME TYPE SAME TAPs SAME
SERIAL# 13180234 ,M TEERD 2.067 SERIALNO SAME D1ANMSEER SAMEREMARKS
The orifice plate was changed to increase the differential pressure. Itwas changed from .750 TO .625
SIGNATURE ÑgWITNESS NOTIFICATION REVIEW
COMPANY BLM CMOENTHAOCD' Phone REVIEWED BY
CONTACT Jeff BTOwn/Lee Oliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE (TegÑom es Û r VITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Services Office:970-245-2490 Fax:970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ORIFICE PLATE CHANGE REPORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'uAST NORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAERA, UTU87659APl430-195-002-90000
EE OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 8:38 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNC
DIFFERENTIAL STATICANA OG 0 RANGE 0-400 ANA OG 1 RANGE 0-1500
TEMPERATURE BASE PRESSURE 14.73AMNAOEG, 2 RANGE 0-150 ATMOSPHERIC PRESSURE 12.36
DIFFERENTIAL PRESSURE BEFOR PLATE CHANGE 2.51 INCHES H2O DIFFERENTIAL PRESSURE AFTER PLATE CHANGE 69.3 INCHES H2O
ORIFICE PLATEREMOVED ORIFICE PLATE INSTALLEDSIZE 2 X 0.750 BETA RATIO 0.375 SIZE 2.000 X 0.625 BETA RATIO 0.3125
CON TON DIRTYSMALL NICK CON TON NEWsEDGRES, YES coiDIRINOGN Good sEDGREs, YES coiDRINOGN GOOD
BEVELED YES BEVELDOWN YES BEVELED YES BEVELDOWN YESPLATE? STREAM? PLATE? STREAM?
DRED OR 0.750 MICSIZE NA 27ED OR 0.625 MICSIZE NC
ORIFICE FITTING ORIFICE FITTINGSIZE 2.067 TYPE DANIEL STATICTAP US SIZE SAME TYPE SAME TAPs SAME
SERIAL# 13180234 ,M TEERD 2.067 SERIALNO SAME D1ANMSEER SAMEREMARKS
The orifice plate was changed to increase the differential pressure. Itwas changed from .750 TO .625
SIGNATURE ÑgWITNESS NOTIFICATION REVIEW
COMPANY BLM CMOENTHAOCD' Phone REVIEWED BY
CONTACT Jeff BTOwn/Lee Oliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE (TegÑom es Û r VITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Services Office:970-245-2490 Fax:970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ORIFICE PLATE CHANGE REPORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'uAST NORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAERA, UTU87659APl430-195-002-90000
EE OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 8:38 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNC
DIFFERENTIAL STATICANA OG 0 RANGE 0-400 ANA OG 1 RANGE 0-1500
TEMPERATURE BASE PRESSURE 14.73AMNAOEG, 2 RANGE 0-150 ATMOSPHERIC PRESSURE 12.36
DIFFERENTIAL PRESSURE BEFOR PLATE CHANGE 2.51 INCHES H2O DIFFERENTIAL PRESSURE AFTER PLATE CHANGE 69.3 INCHES H2O
ORIFICE PLATEREMOVED ORIFICE PLATE INSTALLEDSIZE 2 X 0.750 BETA RATIO 0.375 SIZE 2.000 X 0.625 BETA RATIO 0.3125
CON TON DIRTYSMALL NICK CON TON NEWsEDGRES, YES coiDIRINOGN Good sEDGREs, YES coiDRINOGN GOOD
BEVELED YES BEVELDOWN YES BEVELED YES BEVELDOWN YESPLATE? STREAM? PLATE? STREAM?
DRED OR 0.750 MICSIZE NA 27ED OR 0.625 MICSIZE NC
ORIFICE FITTING ORIFICE FITTINGSIZE 2.067 TYPE DANIEL STATICTAP US SIZE SAME TYPE SAME TAPs SAME
SERIAL# 13180234 ,M TEERD 2.067 SERIALNO SAME D1ANMSEER SAMEREMARKS
The orifice plate was changed to increase the differential pressure. Itwas changed from .750 TO .625
SIGNATURE ÑgWITNESS NOTIFICATION REVIEW
COMPANY BLM CMOENTHAOCD' Phone REVIEWED BY
CONTACT Jeff BTOwn/Lee Oliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE (TegÑom es Û r VITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Services Office:970-245-2490 Fax:970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ORIFICE PLATE CHANGE REPORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'uAST NORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAERA, UTU87659APl430-195-002-90000
EE OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 8:38 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNC
DIFFERENTIAL STATICANA OG 0 RANGE 0-400 ANA OG 1 RANGE 0-1500
TEMPERATURE BASE PRESSURE 14.73AMNAOEG, 2 RANGE 0-150 ATMOSPHERIC PRESSURE 12.36
DIFFERENTIAL PRESSURE BEFOR PLATE CHANGE 2.51 INCHES H2O DIFFERENTIAL PRESSURE AFTER PLATE CHANGE 69.3 INCHES H2O
ORIFICE PLATEREMOVED ORIFICE PLATE INSTALLEDSIZE 2 X 0.750 BETA RATIO 0.375 SIZE 2.000 X 0.625 BETA RATIO 0.3125
CON TON DIRTYSMALL NICK CON TON NEWsEDGRES, YES coiDIRINOGN Good sEDGREs, YES coiDRINOGN GOOD
BEVELED YES BEVELDOWN YES BEVELED YES BEVELDOWN YESPLATE? STREAM? PLATE? STREAM?
DRED OR 0.750 MICSIZE NA 27ED OR 0.625 MICSIZE NC
ORIFICE FITTING ORIFICE FITTINGSIZE 2.067 TYPE DANIEL STATICTAP US SIZE SAME TYPE SAME TAPs SAME
SERIAL# 13180234 ,M TEERD 2.067 SERIALNO SAME D1ANMSEER SAMEREMARKS
The orifice plate was changed to increase the differential pressure. Itwas changed from .750 TO .625
SIGNATURE ÑgWITNESS NOTIFICATION REVIEW
COMPANY BLM CMOENTHAOCD' Phone REVIEWED BY
CONTACT Jeff BTOwn/Lee Oliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE (TegÑom es Û r VITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Services Office:970-245-2490 Fax:970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ORIFICE PLATE CHANGE REPORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'uAST NORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAERA, UTU87659APl430-195-002-90000
EE OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 8:38 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNC
DIFFERENTIAL STATICANA OG 0 RANGE 0-400 ANA OG 1 RANGE 0-1500
TEMPERATURE BASE PRESSURE 14.73AMNAOEG, 2 RANGE 0-150 ATMOSPHERIC PRESSURE 12.36
DIFFERENTIAL PRESSURE BEFOR PLATE CHANGE 2.51 INCHES H2O DIFFERENTIAL PRESSURE AFTER PLATE CHANGE 69.3 INCHES H2O
ORIFICE PLATEREMOVED ORIFICE PLATE INSTALLEDSIZE 2 X 0.750 BETA RATIO 0.375 SIZE 2.000 X 0.625 BETA RATIO 0.3125
CON TON DIRTYSMALL NICK CON TON NEWsEDGRES, YES coiDIRINOGN Good sEDGREs, YES coiDRINOGN GOOD
BEVELED YES BEVELDOWN YES BEVELED YES BEVELDOWN YESPLATE? STREAM? PLATE? STREAM?
DRED OR 0.750 MICSIZE NA 27ED OR 0.625 MICSIZE NC
ORIFICE FITTING ORIFICE FITTINGSIZE 2.067 TYPE DANIEL STATICTAP US SIZE SAME TYPE SAME TAPs SAME
SERIAL# 13180234 ,M TEERD 2.067 SERIALNO SAME D1ANMSEER SAMEREMARKS
The orifice plate was changed to increase the differential pressure. Itwas changed from .750 TO .625
SIGNATURE ÑgWITNESS NOTIFICATION REVIEW
COMPANY BLM CMOENTHAOCD' Phone REVIEWED BY
CONTACT Jeff BTOwn/Lee Oliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE (TegÑom es Û r VITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Services Office:970-245-2490 Fax:970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ORIFICE PLATE CHANGE REPORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'uAST NORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAERA, UTU87659APl430-195-002-90000
EE OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 8:38 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNC
DIFFERENTIAL STATICANA OG 0 RANGE 0-400 ANA OG 1 RANGE 0-1500
TEMPERATURE BASE PRESSURE 14.73AMNAOEG, 2 RANGE 0-150 ATMOSPHERIC PRESSURE 12.36
DIFFERENTIAL PRESSURE BEFOR PLATE CHANGE 2.51 INCHES H2O DIFFERENTIAL PRESSURE AFTER PLATE CHANGE 69.3 INCHES H2O
ORIFICE PLATEREMOVED ORIFICE PLATE INSTALLEDSIZE 2 X 0.750 BETA RATIO 0.375 SIZE 2.000 X 0.625 BETA RATIO 0.3125
CON TON DIRTYSMALL NICK CON TON NEWsEDGRES, YES coiDIRINOGN Good sEDGREs, YES coiDRINOGN GOOD
BEVELED YES BEVELDOWN YES BEVELED YES BEVELDOWN YESPLATE? STREAM? PLATE? STREAM?
DRED OR 0.750 MICSIZE NA 27ED OR 0.625 MICSIZE NC
ORIFICE FITTING ORIFICE FITTINGSIZE 2.067 TYPE DANIEL STATICTAP US SIZE SAME TYPE SAME TAPs SAME
SERIAL# 13180234 ,M TEERD 2.067 SERIALNO SAME D1ANMSEER SAMEREMARKS
The orifice plate was changed to increase the differential pressure. Itwas changed from .750 TO .625
SIGNATURE ÑgWITNESS NOTIFICATION REVIEW
COMPANY BLM CMOENTHAOCD' Phone REVIEWED BY
CONTACT Jeff BTOwn/Lee Oliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE (TegÑom es Û r VITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Services Office:970-245-2490 Fax:970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ORIFICE PLATE CHANGE REPORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'uAST NORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAERA, UTU87659APl430-195-002-90000
EE OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 8:38 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNC
DIFFERENTIAL STATICANA OG 0 RANGE 0-400 ANA OG 1 RANGE 0-1500
TEMPERATURE BASE PRESSURE 14.73AMNAOEG, 2 RANGE 0-150 ATMOSPHERIC PRESSURE 12.36
DIFFERENTIAL PRESSURE BEFOR PLATE CHANGE 2.51 INCHES H2O DIFFERENTIAL PRESSURE AFTER PLATE CHANGE 69.3 INCHES H2O
ORIFICE PLATEREMOVED ORIFICE PLATE INSTALLEDSIZE 2 X 0.750 BETA RATIO 0.375 SIZE 2.000 X 0.625 BETA RATIO 0.3125
CON TON DIRTYSMALL NICK CON TON NEWsEDGRES, YES coiDIRINOGN Good sEDGREs, YES coiDRINOGN GOOD
BEVELED YES BEVELDOWN YES BEVELED YES BEVELDOWN YESPLATE? STREAM? PLATE? STREAM?
DRED OR 0.750 MICSIZE NA 27ED OR 0.625 MICSIZE NC
ORIFICE FITTING ORIFICE FITTINGSIZE 2.067 TYPE DANIEL STATICTAP US SIZE SAME TYPE SAME TAPs SAME
SERIAL# 13180234 ,M TEERD 2.067 SERIALNO SAME D1ANMSEER SAMEREMARKS
The orifice plate was changed to increase the differential pressure. Itwas changed from .750 TO .625
SIGNATURE ÑgWITNESS NOTIFICATION REVIEW
COMPANY BLM CMOENTHAOCD' Phone REVIEWED BY
CONTACT Jeff BTOwn/Lee Oliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE (TegÑom es Û r VITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Services Office:970-245-2490 Fax:970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ORIFICE PLATE CHANGE REPORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'uAST NORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAERA, UTU87659APl430-195-002-90000
EE OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 8:38 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNC
DIFFERENTIAL STATICANA OG 0 RANGE 0-400 ANA OG 1 RANGE 0-1500
TEMPERATURE BASE PRESSURE 14.73AMNAOEG, 2 RANGE 0-150 ATMOSPHERIC PRESSURE 12.36
DIFFERENTIAL PRESSURE BEFOR PLATE CHANGE 2.51 INCHES H2O DIFFERENTIAL PRESSURE AFTER PLATE CHANGE 69.3 INCHES H2O
ORIFICE PLATEREMOVED ORIFICE PLATE INSTALLEDSIZE 2 X 0.750 BETA RATIO 0.375 SIZE 2.000 X 0.625 BETA RATIO 0.3125
CON TON DIRTYSMALL NICK CON TON NEWsEDGRES, YES coiDIRINOGN Good sEDGREs, YES coiDRINOGN GOOD
BEVELED YES BEVELDOWN YES BEVELED YES BEVELDOWN YESPLATE? STREAM? PLATE? STREAM?
DRED OR 0.750 MICSIZE NA 27ED OR 0.625 MICSIZE NC
ORIFICE FITTING ORIFICE FITTINGSIZE 2.067 TYPE DANIEL STATICTAP US SIZE SAME TYPE SAME TAPs SAME
SERIAL# 13180234 ,M TEERD 2.067 SERIALNO SAME D1ANMSEER SAMEREMARKS
The orifice plate was changed to increase the differential pressure. Itwas changed from .750 TO .625
SIGNATURE ÑgWITNESS NOTIFICATION REVIEW
COMPANY BLM CMOENTHAOCD' Phone REVIEWED BY
CONTACT Jeff BTOwn/Lee Oliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE (TegÑom es Û r VITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Services Office:970-245-2490 Fax:970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ORIFICE PLATE CHANGE REPORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'uAST NORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAERA, UTU87659APl430-195-002-90000
EE OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 8:38 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNC
DIFFERENTIAL STATICANA OG 0 RANGE 0-400 ANA OG 1 RANGE 0-1500
TEMPERATURE BASE PRESSURE 14.73AMNAOEG, 2 RANGE 0-150 ATMOSPHERIC PRESSURE 12.36
DIFFERENTIAL PRESSURE BEFOR PLATE CHANGE 2.51 INCHES H2O DIFFERENTIAL PRESSURE AFTER PLATE CHANGE 69.3 INCHES H2O
ORIFICE PLATEREMOVED ORIFICE PLATE INSTALLEDSIZE 2 X 0.750 BETA RATIO 0.375 SIZE 2.000 X 0.625 BETA RATIO 0.3125
CON TON DIRTYSMALL NICK CON TON NEWsEDGRES, YES coiDIRINOGN Good sEDGREs, YES coiDRINOGN GOOD
BEVELED YES BEVELDOWN YES BEVELED YES BEVELDOWN YESPLATE? STREAM? PLATE? STREAM?
DRED OR 0.750 MICSIZE NA 27ED OR 0.625 MICSIZE NC
ORIFICE FITTING ORIFICE FITTINGSIZE 2.067 TYPE DANIEL STATICTAP US SIZE SAME TYPE SAME TAPs SAME
SERIAL# 13180234 ,M TEERD 2.067 SERIALNO SAME D1ANMSEER SAMEREMARKS
The orifice plate was changed to increase the differential pressure. Itwas changed from .750 TO .625
SIGNATURE ÑgWITNESS NOTIFICATION REVIEW
COMPANY BLM CMOENTHAOCD' Phone REVIEWED BY
CONTACT Jeff BTOwn/Lee Oliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE (TegÑom es Û r VITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Services Office:970-245-2490 Fax:970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ORIFICE PLATE CHANGE REPORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'uAST NORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAERA, UTU87659APl430-195-002-90000
EE OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 8:38 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNC
DIFFERENTIAL STATICANA OG 0 RANGE 0-400 ANA OG 1 RANGE 0-1500
TEMPERATURE BASE PRESSURE 14.73AMNAOEG, 2 RANGE 0-150 ATMOSPHERIC PRESSURE 12.36
DIFFERENTIAL PRESSURE BEFOR PLATE CHANGE 2.51 INCHES H2O DIFFERENTIAL PRESSURE AFTER PLATE CHANGE 69.3 INCHES H2O
ORIFICE PLATEREMOVED ORIFICE PLATE INSTALLEDSIZE 2 X 0.750 BETA RATIO 0.375 SIZE 2.000 X 0.625 BETA RATIO 0.3125
CON TON DIRTYSMALL NICK CON TON NEWsEDGRES, YES coiDIRINOGN Good sEDGREs, YES coiDRINOGN GOOD
BEVELED YES BEVELDOWN YES BEVELED YES BEVELDOWN YESPLATE? STREAM? PLATE? STREAM?
DRED OR 0.750 MICSIZE NA 27ED OR 0.625 MICSIZE NC
ORIFICE FITTING ORIFICE FITTINGSIZE 2.067 TYPE DANIEL STATICTAP US SIZE SAME TYPE SAME TAPs SAME
SERIAL# 13180234 ,M TEERD 2.067 SERIALNO SAME D1ANMSEER SAMEREMARKS
The orifice plate was changed to increase the differential pressure. Itwas changed from .750 TO .625
SIGNATURE ÑgWITNESS NOTIFICATION REVIEW
COMPANY BLM CMOENTHAOCD' Phone REVIEWED BY
CONTACT Jeff BTOwn/Lee Oliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE (TegÑom es Û r VITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Services Office:970-245-2490 Fax:970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ORIFICE PLATE CHANGE REPORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'uAST NORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAERA, UTU87659APl430-195-002-90000
EE OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 8:38 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNC
DIFFERENTIAL STATICANA OG 0 RANGE 0-400 ANA OG 1 RANGE 0-1500
TEMPERATURE BASE PRESSURE 14.73AMNAOEG, 2 RANGE 0-150 ATMOSPHERIC PRESSURE 12.36
DIFFERENTIAL PRESSURE BEFOR PLATE CHANGE 2.51 INCHES H2O DIFFERENTIAL PRESSURE AFTER PLATE CHANGE 69.3 INCHES H2O
ORIFICE PLATEREMOVED ORIFICE PLATE INSTALLEDSIZE 2 X 0.750 BETA RATIO 0.375 SIZE 2.000 X 0.625 BETA RATIO 0.3125
CON TON DIRTYSMALL NICK CON TON NEWsEDGRES, YES coiDIRINOGN Good sEDGREs, YES coiDRINOGN GOOD
BEVELED YES BEVELDOWN YES BEVELED YES BEVELDOWN YESPLATE? STREAM? PLATE? STREAM?
DRED OR 0.750 MICSIZE NA 27ED OR 0.625 MICSIZE NC
ORIFICE FITTING ORIFICE FITTINGSIZE 2.067 TYPE DANIEL STATICTAP US SIZE SAME TYPE SAME TAPs SAME
SERIAL# 13180234 ,M TEERD 2.067 SERIALNO SAME D1ANMSEER SAMEREMARKS
The orifice plate was changed to increase the differential pressure. Itwas changed from .750 TO .625
SIGNATURE ÑgWITNESS NOTIFICATION REVIEW
COMPANY BLM CMOENTHAOCD' Phone REVIEWED BY
CONTACT Jeff BTOwn/Lee Oliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE (TegÑom es Û r VITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Services Office:970-245-2490 Fax:970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ORIFICE PLATE CHANGE REPORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'uAST NORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAERA, UTU87659APl430-195-002-90000
EE OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 8:38 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNC
DIFFERENTIAL STATICANA OG 0 RANGE 0-400 ANA OG 1 RANGE 0-1500
TEMPERATURE BASE PRESSURE 14.73AMNAOEG, 2 RANGE 0-150 ATMOSPHERIC PRESSURE 12.36
DIFFERENTIAL PRESSURE BEFOR PLATE CHANGE 2.51 INCHES H2O DIFFERENTIAL PRESSURE AFTER PLATE CHANGE 69.3 INCHES H2O
ORIFICE PLATEREMOVED ORIFICE PLATE INSTALLEDSIZE 2 X 0.750 BETA RATIO 0.375 SIZE 2.000 X 0.625 BETA RATIO 0.3125
CON TON DIRTYSMALL NICK CON TON NEWsEDGRES, YES coiDIRINOGN Good sEDGREs, YES coiDRINOGN GOOD
BEVELED YES BEVELDOWN YES BEVELED YES BEVELDOWN YESPLATE? STREAM? PLATE? STREAM?
DRED OR 0.750 MICSIZE NA 27ED OR 0.625 MICSIZE NC
ORIFICE FITTING ORIFICE FITTINGSIZE 2.067 TYPE DANIEL STATICTAP US SIZE SAME TYPE SAME TAPs SAME
SERIAL# 13180234 ,M TEERD 2.067 SERIALNO SAME D1ANMSEER SAMEREMARKS
The orifice plate was changed to increase the differential pressure. Itwas changed from .750 TO .625
SIGNATURE ÑgWITNESS NOTIFICATION REVIEW
COMPANY BLM CMOENTHAOCD' Phone REVIEWED BY
CONTACT Jeff BTOwn/Lee Oliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE (TegÑom es Û r VITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Services Office:970-245-2490 Fax:970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ORIFICE PLATE CHANGE REPORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 3/23/2015
c'uAST NORR FEDERAL1-4 RTUADDRESS 100 RTUGROUP 21 FEEDAERA, UTU87659APl430-195-002-90000
EE OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 8:38 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNC
DIFFERENTIAL STATICANA OG 0 RANGE 0-400 ANA OG 1 RANGE 0-1500
TEMPERATURE BASE PRESSURE 14.73AMNAOEG, 2 RANGE 0-150 ATMOSPHERIC PRESSURE 12.36
DIFFERENTIAL PRESSURE BEFOR PLATE CHANGE 2.51 INCHES H2O DIFFERENTIAL PRESSURE AFTER PLATE CHANGE 69.3 INCHES H2O
ORIFICE PLATEREMOVED ORIFICE PLATE INSTALLEDSIZE 2 X 0.750 BETA RATIO 0.375 SIZE 2.000 X 0.625 BETA RATIO 0.3125
CON TON DIRTYSMALL NICK CON TON NEWsEDGRES, YES coiDIRINOGN Good sEDGREs, YES coiDRINOGN GOOD
BEVELED YES BEVELDOWN YES BEVELED YES BEVELDOWN YESPLATE? STREAM? PLATE? STREAM?
DRED OR 0.750 MICSIZE NA 27ED OR 0.625 MICSIZE NC
ORIFICE FITTING ORIFICE FITTINGSIZE 2.067 TYPE DANIEL STATICTAP US SIZE SAME TYPE SAME TAPs SAME
SERIAL# 13180234 ,M TEERD 2.067 SERIALNO SAME D1ANMSEER SAMEREMARKS
The orifice plate was changed to increase the differential pressure. Itwas changed from .750 TO .625
SIGNATURE ÑgWITNESS NOTIFICATION REVIEW
COMPANY BLM CMOENTHAOCD' Phone REVIEWED BY
CONTACT Jeff BTOwn/Lee Oliver DATE 3/19/2015 DATE 3/27/2015
WITNESS SIGNATURE (TegÑom es Û r VITNESS DATE
STATE OF UTAH DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING
SUNDRY NOTICES AND REPORTS ON WELLS
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILL form for such proposals.
1. TYPE OF WELL OIL WELL D GAS WELL D OTHER helium
2. NAME OF OPERATOR:
Flatirons Resources LLC 3. ADDRESS OF OPERATOR:
11080 Circle Point Road CITY Westminster STATE CO ZIP 80020 4. LOCATION OF WELL
FOOTAGES AT SURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E
OTRIOTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E
I PHONE NUMBER:
(303) 292-3902
FORM 9
5. LEASE DESIGNATION AND SERIAL NUMBER:
UTU 87659 6. IF INDIAN, ALLOTIEE OR TRIBE NAME:
7. UNIT or CA AGREEMENT NAME:
8. WELL NAME and NUMBER:
Flatirons Federal #1-4 9. API NUMBER:
4301950029 10. FIELD AND POOL, OR WILDCAT:
Greater Cisco
COUNTY: Grand County
STATE:
UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
D D ACIDIZE D DEEPEN D REPERFORATE CURRENT FORMATION NOTICE OF INTENT
(Submit in Duplicate) D ALTER CASING D FRACTURE TREAT D SIDETRACK TO REPAIR WELL
Approximate date work will start: D CASING REPAIR D NEW CONSTRUCTION D TEMPORARILY ABANDON
D CHANGE TO PREVIOUS PLANS D OPERA TOR CHANGE D TUBING REPAIR
D CHANGE TUBING D PLUG AND ABANDON D VENT OR FLARE
G2( SUBSEQUENT REPORT D CHANGE WELL NAME D PLUG BACK D WATER DISPOSAL (Submit Original Form Only)
D CHANGE WELL STATUS D PRODUCTION (START/RESUME) D WATER SHUT-OFF Date of work completion:
D COMMINGLE PRODUCING FORMATIONS D RECLAMATION OF WELL SITE III OTHER: Flow Measurement
D CONVERT WELL TYPE D RECOMPLETE - DIFFERENT FORMATION Calibration Report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate and verified RTD, the differential and static pressures were calibrated
NAME (PLEASE PRINT) Jeffery E. Jones TITLE Managing Director
"G~ru~ ciY(j:: DATE 7/1/2015
(This space for State use only)
(5/2000) (See Instructions on Reverse Side)
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAMESUNDRY NOTICESAND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road Westminster STATE CO ZIP 80020 (303) 292-3902 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 75T FEL Sec 4, T19S, R25E COUNTY Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Flow MeasurementO CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Calibration Report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS.Clearly show all pertinent details including dates, depths, volumes, etc
Cleaned and inspected the orificeplate and verified RTD, the differential and static pressures were calibrated
NAME (PLEASE PRINT) Jeffery E. Jones
SIGNATURE
TEE Mana01in5gDirector
(This space for State use only)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAMESUNDRY NOTICESAND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road Westminster STATE CO ZIP 80020 (303) 292-3902 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 75T FEL Sec 4, T19S, R25E COUNTY Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Flow MeasurementO CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Calibration Report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS.Clearly show all pertinent details including dates, depths, volumes, etc
Cleaned and inspected the orificeplate and verified RTD, the differential and static pressures were calibrated
NAME (PLEASE PRINT) Jeffery E. Jones
SIGNATURE
TEE Mana01in5gDirector
(This space for State use only)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAMESUNDRY NOTICESAND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road Westminster STATE CO ZIP 80020 (303) 292-3902 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 75T FEL Sec 4, T19S, R25E COUNTY Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Flow MeasurementO CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Calibration Report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS.Clearly show all pertinent details including dates, depths, volumes, etc
Cleaned and inspected the orificeplate and verified RTD, the differential and static pressures were calibrated
NAME (PLEASE PRINT) Jeffery E. Jones
SIGNATURE
TEE Mana01in5gDirector
(This space for State use only)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAMESUNDRY NOTICESAND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road Westminster STATE CO ZIP 80020 (303) 292-3902 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 75T FEL Sec 4, T19S, R25E COUNTY Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Flow MeasurementO CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Calibration Report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS.Clearly show all pertinent details including dates, depths, volumes, etc
Cleaned and inspected the orificeplate and verified RTD, the differential and static pressures were calibrated
NAME (PLEASE PRINT) Jeffery E. Jones
SIGNATURE
TEE Mana01in5gDirector
(This space for State use only)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAMESUNDRY NOTICESAND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road Westminster STATE CO ZIP 80020 (303) 292-3902 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 75T FEL Sec 4, T19S, R25E COUNTY Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Flow MeasurementO CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Calibration Report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS.Clearly show all pertinent details including dates, depths, volumes, etc
Cleaned and inspected the orificeplate and verified RTD, the differential and static pressures were calibrated
NAME (PLEASE PRINT) Jeffery E. Jones
SIGNATURE
TEE Mana01in5gDirector
(This space for State use only)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAMESUNDRY NOTICESAND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road Westminster STATE CO ZIP 80020 (303) 292-3902 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 75T FEL Sec 4, T19S, R25E COUNTY Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Flow MeasurementO CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Calibration Report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS.Clearly show all pertinent details including dates, depths, volumes, etc
Cleaned and inspected the orificeplate and verified RTD, the differential and static pressures were calibrated
NAME (PLEASE PRINT) Jeffery E. Jones
SIGNATURE
TEE Mana01in5gDirector
(This space for State use only)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAMESUNDRY NOTICESAND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road Westminster STATE CO ZIP 80020 (303) 292-3902 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 75T FEL Sec 4, T19S, R25E COUNTY Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Flow MeasurementO CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Calibration Report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS.Clearly show all pertinent details including dates, depths, volumes, etc
Cleaned and inspected the orificeplate and verified RTD, the differential and static pressures were calibrated
NAME (PLEASE PRINT) Jeffery E. Jones
SIGNATURE
TEE Mana01in5gDirector
(This space for State use only)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAMESUNDRY NOTICESAND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road Westminster STATE CO ZIP 80020 (303) 292-3902 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 75T FEL Sec 4, T19S, R25E COUNTY Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Flow MeasurementO CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Calibration Report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS.Clearly show all pertinent details including dates, depths, volumes, etc
Cleaned and inspected the orificeplate and verified RTD, the differential and static pressures were calibrated
NAME (PLEASE PRINT) Jeffery E. Jones
SIGNATURE
TEE Mana01in5gDirector
(This space for State use only)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAMESUNDRY NOTICESAND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road Westminster STATE CO ZIP 80020 (303) 292-3902 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 75T FEL Sec 4, T19S, R25E COUNTY Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Flow MeasurementO CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Calibration Report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS.Clearly show all pertinent details including dates, depths, volumes, etc
Cleaned and inspected the orificeplate and verified RTD, the differential and static pressures were calibrated
NAME (PLEASE PRINT) Jeffery E. Jones
SIGNATURE
TEE Mana01in5gDirector
(This space for State use only)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAMESUNDRY NOTICESAND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road Westminster STATE CO ZIP 80020 (303) 292-3902 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 75T FEL Sec 4, T19S, R25E COUNTY Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Flow MeasurementO CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Calibration Report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS.Clearly show all pertinent details including dates, depths, volumes, etc
Cleaned and inspected the orificeplate and verified RTD, the differential and static pressures were calibrated
NAME (PLEASE PRINT) Jeffery E. Jones
SIGNATURE
TEE Mana01in5gDirector
(This space for State use only)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAMESUNDRY NOTICESAND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road Westminster STATE CO ZIP 80020 (303) 292-3902 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 75T FEL Sec 4, T19S, R25E COUNTY Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Flow MeasurementO CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Calibration Report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS.Clearly show all pertinent details including dates, depths, volumes, etc
Cleaned and inspected the orificeplate and verified RTD, the differential and static pressures were calibrated
NAME (PLEASE PRINT) Jeffery E. Jones
SIGNATURE
TEE Mana01in5gDirector
(This space for State use only)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAMESUNDRY NOTICESAND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road Westminster STATE CO ZIP 80020 (303) 292-3902 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 75T FEL Sec 4, T19S, R25E COUNTY Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Flow MeasurementO CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Calibration Report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS.Clearly show all pertinent details including dates, depths, volumes, etc
Cleaned and inspected the orificeplate and verified RTD, the differential and static pressures were calibrated
NAME (PLEASE PRINT) Jeffery E. Jones
SIGNATURE
TEE Mana01in5gDirector
(This space for State use only)
(5/2000) (See Instructions on Reverse
nr Services
Production Management Measurement, Analytical, Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORT LOCATION NO. 100 COUNTY GRAND STATE 6/26/2015
Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP
N 39 11. 221' .0" LOGITUDE
PRESS
LIVE DIFFERENTIIAL FOUND 86.99 LIVE DIFFERENTIIAL LEFT 131.16 LIVE STATIC PRESS FOUND 73.51 LIVE STATIC PRESS LEFT 57.97
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.03 -0.01% 0 0 0.18 -0.04% 0
200 200.02 -0.01% 200 250 250.27 -0.05% 250
400 400.57 -0.14% 400 500 500.31 -0.06% 500
Do not drive RTD if flowing temp. is + or- 0.5 degrees of test thermometer
GOOD AS FOUND AS LEFT
YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
#DIV/Ol
#DIV/Ol
SERIAL #
FLOW COMPUTER THERMOMETER FLOW COMPUTER
94.3 Same Same
and static pressures were calibrated.
~\07. 90 In;
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/26/2015
c'u^s'ËNIERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS) OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:00 PM
TRANSDUCER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL 1833-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,SERIAL# RECALIB DATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016 RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 ""°s"s:D R 0.06 RSSAWOS 0.03 ANALOG RANGE 0-1500 &^fs 14.73 ^"°6 12.36
LIVEDIFFERENTilALFOUND 86.99 LIVEDIFFERENTIIALLEFT 131.16 LIVESTATIC PRESS FOUND 73.51 LIVESTATIC PRESS LEFT 57.97
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.03 -0.01% 0 0 0.18 -0.04% 0
200 200.02 -0.01% 200 250 250.27 -0.05% 250
400 400.57 -0.14% 400 500 500.31 -0.06% 500
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CONITEON Dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometer
E E YES COEANDRINOGN GOOD AS FOUND AS LEFTE ELEED YES BEVERLEDOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMI ERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 94.3 94.3 Same SameCleaned and inspected the orifice plate and verified the RTL , the differential and static pressures were calibrated.
TECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY REVIEWED BY
CONTACT DATE DATE 6/30/2015WITNESS SIGNATURE 41TNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/26/2015
c'u^s'ËNIERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS) OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:00 PM
TRANSDUCER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL 1833-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,SERIAL# RECALIB DATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016 RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 ""°s"s:D R 0.06 RSSAWOS 0.03 ANALOG RANGE 0-1500 &^fs 14.73 ^"°6 12.36
LIVEDIFFERENTilALFOUND 86.99 LIVEDIFFERENTIIALLEFT 131.16 LIVESTATIC PRESS FOUND 73.51 LIVESTATIC PRESS LEFT 57.97
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.03 -0.01% 0 0 0.18 -0.04% 0
200 200.02 -0.01% 200 250 250.27 -0.05% 250
400 400.57 -0.14% 400 500 500.31 -0.06% 500
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CONITEON Dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometer
E E YES COEANDRINOGN GOOD AS FOUND AS LEFTE ELEED YES BEVERLEDOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMI ERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 94.3 94.3 Same SameCleaned and inspected the orifice plate and verified the RTL , the differential and static pressures were calibrated.
TECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY REVIEWED BY
CONTACT DATE DATE 6/30/2015WITNESS SIGNATURE 41TNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/26/2015
c'u^s'ËNIERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS) OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:00 PM
TRANSDUCER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL 1833-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,SERIAL# RECALIB DATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016 RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 ""°s"s:D R 0.06 RSSAWOS 0.03 ANALOG RANGE 0-1500 &^fs 14.73 ^"°6 12.36
LIVEDIFFERENTilALFOUND 86.99 LIVEDIFFERENTIIALLEFT 131.16 LIVESTATIC PRESS FOUND 73.51 LIVESTATIC PRESS LEFT 57.97
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.03 -0.01% 0 0 0.18 -0.04% 0
200 200.02 -0.01% 200 250 250.27 -0.05% 250
400 400.57 -0.14% 400 500 500.31 -0.06% 500
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CONITEON Dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometer
E E YES COEANDRINOGN GOOD AS FOUND AS LEFTE ELEED YES BEVERLEDOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMI ERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 94.3 94.3 Same SameCleaned and inspected the orifice plate and verified the RTL , the differential and static pressures were calibrated.
TECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY REVIEWED BY
CONTACT DATE DATE 6/30/2015WITNESS SIGNATURE 41TNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/26/2015
c'u^s'ËNIERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS) OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:00 PM
TRANSDUCER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL 1833-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,SERIAL# RECALIB DATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016 RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 ""°s"s:D R 0.06 RSSAWOS 0.03 ANALOG RANGE 0-1500 &^fs 14.73 ^"°6 12.36
LIVEDIFFERENTilALFOUND 86.99 LIVEDIFFERENTIIALLEFT 131.16 LIVESTATIC PRESS FOUND 73.51 LIVESTATIC PRESS LEFT 57.97
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.03 -0.01% 0 0 0.18 -0.04% 0
200 200.02 -0.01% 200 250 250.27 -0.05% 250
400 400.57 -0.14% 400 500 500.31 -0.06% 500
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CONITEON Dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometer
E E YES COEANDRINOGN GOOD AS FOUND AS LEFTE ELEED YES BEVERLEDOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMI ERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 94.3 94.3 Same SameCleaned and inspected the orifice plate and verified the RTL , the differential and static pressures were calibrated.
TECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY REVIEWED BY
CONTACT DATE DATE 6/30/2015WITNESS SIGNATURE 41TNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/26/2015
c'u^s'ËNIERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS) OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:00 PM
TRANSDUCER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL 1833-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,SERIAL# RECALIB DATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016 RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 ""°s"s:D R 0.06 RSSAWOS 0.03 ANALOG RANGE 0-1500 &^fs 14.73 ^"°6 12.36
LIVEDIFFERENTilALFOUND 86.99 LIVEDIFFERENTIIALLEFT 131.16 LIVESTATIC PRESS FOUND 73.51 LIVESTATIC PRESS LEFT 57.97
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.03 -0.01% 0 0 0.18 -0.04% 0
200 200.02 -0.01% 200 250 250.27 -0.05% 250
400 400.57 -0.14% 400 500 500.31 -0.06% 500
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CONITEON Dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometer
E E YES COEANDRINOGN GOOD AS FOUND AS LEFTE ELEED YES BEVERLEDOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMI ERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 94.3 94.3 Same SameCleaned and inspected the orifice plate and verified the RTL , the differential and static pressures were calibrated.
TECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY REVIEWED BY
CONTACT DATE DATE 6/30/2015WITNESS SIGNATURE 41TNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/26/2015
c'u^s'ËNIERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS) OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:00 PM
TRANSDUCER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL 1833-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,SERIAL# RECALIB DATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016 RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 ""°s"s:D R 0.06 RSSAWOS 0.03 ANALOG RANGE 0-1500 &^fs 14.73 ^"°6 12.36
LIVEDIFFERENTilALFOUND 86.99 LIVEDIFFERENTIIALLEFT 131.16 LIVESTATIC PRESS FOUND 73.51 LIVESTATIC PRESS LEFT 57.97
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.03 -0.01% 0 0 0.18 -0.04% 0
200 200.02 -0.01% 200 250 250.27 -0.05% 250
400 400.57 -0.14% 400 500 500.31 -0.06% 500
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CONITEON Dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometer
E E YES COEANDRINOGN GOOD AS FOUND AS LEFTE ELEED YES BEVERLEDOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMI ERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 94.3 94.3 Same SameCleaned and inspected the orifice plate and verified the RTL , the differential and static pressures were calibrated.
TECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY REVIEWED BY
CONTACT DATE DATE 6/30/2015WITNESS SIGNATURE 41TNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/26/2015
c'u^s'ËNIERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS) OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:00 PM
TRANSDUCER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL 1833-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,SERIAL# RECALIB DATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016 RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 ""°s"s:D R 0.06 RSSAWOS 0.03 ANALOG RANGE 0-1500 &^fs 14.73 ^"°6 12.36
LIVEDIFFERENTilALFOUND 86.99 LIVEDIFFERENTIIALLEFT 131.16 LIVESTATIC PRESS FOUND 73.51 LIVESTATIC PRESS LEFT 57.97
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.03 -0.01% 0 0 0.18 -0.04% 0
200 200.02 -0.01% 200 250 250.27 -0.05% 250
400 400.57 -0.14% 400 500 500.31 -0.06% 500
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CONITEON Dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometer
E E YES COEANDRINOGN GOOD AS FOUND AS LEFTE ELEED YES BEVERLEDOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMI ERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 94.3 94.3 Same SameCleaned and inspected the orifice plate and verified the RTL , the differential and static pressures were calibrated.
TECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY REVIEWED BY
CONTACT DATE DATE 6/30/2015WITNESS SIGNATURE 41TNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/26/2015
c'u^s'ËNIERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS) OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:00 PM
TRANSDUCER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL 1833-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,SERIAL# RECALIB DATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016 RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 ""°s"s:D R 0.06 RSSAWOS 0.03 ANALOG RANGE 0-1500 &^fs 14.73 ^"°6 12.36
LIVEDIFFERENTilALFOUND 86.99 LIVEDIFFERENTIIALLEFT 131.16 LIVESTATIC PRESS FOUND 73.51 LIVESTATIC PRESS LEFT 57.97
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.03 -0.01% 0 0 0.18 -0.04% 0
200 200.02 -0.01% 200 250 250.27 -0.05% 250
400 400.57 -0.14% 400 500 500.31 -0.06% 500
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CONITEON Dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometer
E E YES COEANDRINOGN GOOD AS FOUND AS LEFTE ELEED YES BEVERLEDOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMI ERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 94.3 94.3 Same SameCleaned and inspected the orifice plate and verified the RTL , the differential and static pressures were calibrated.
TECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY REVIEWED BY
CONTACT DATE DATE 6/30/2015WITNESS SIGNATURE 41TNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/26/2015
c'u^s'ËNIERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS) OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:00 PM
TRANSDUCER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL 1833-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,SERIAL# RECALIB DATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016 RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 ""°s"s:D R 0.06 RSSAWOS 0.03 ANALOG RANGE 0-1500 &^fs 14.73 ^"°6 12.36
LIVEDIFFERENTilALFOUND 86.99 LIVEDIFFERENTIIALLEFT 131.16 LIVESTATIC PRESS FOUND 73.51 LIVESTATIC PRESS LEFT 57.97
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.03 -0.01% 0 0 0.18 -0.04% 0
200 200.02 -0.01% 200 250 250.27 -0.05% 250
400 400.57 -0.14% 400 500 500.31 -0.06% 500
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CONITEON Dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometer
E E YES COEANDRINOGN GOOD AS FOUND AS LEFTE ELEED YES BEVERLEDOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMI ERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 94.3 94.3 Same SameCleaned and inspected the orifice plate and verified the RTL , the differential and static pressures were calibrated.
TECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY REVIEWED BY
CONTACT DATE DATE 6/30/2015WITNESS SIGNATURE 41TNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/26/2015
c'u^s'âNIERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS) OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:00 PM
TRANSDUCER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL 1833-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,SERIAL# RECALIB DATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016 RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 ""°s"s:D R 0.06 RSSAWOS 0.03 ANALOG RANGE 0-1500 &^fs 14.73 ^"°6 12.36
LIVEDIFFERENTilALFOUND 86.99 LIVEDIFFERENTIIALLEFT 131.16 LIVESTATIC PRESS FOUND 73.51 LIVESTATIC PRESS LEFT 57.97
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.03 -0.01% 0 0 0.18 -0.04% 0
200 200.02 -0.01% 200 250 250.27 -0.05% 250
400 400.57 -0.14% 400 500 500.31 -0.06% 500
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CONITEON Dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometer
E E YES COEANDRINOGN GOOD AS FOUND AS LEFTE ELEED YES BEVERLEDOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
PEDOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMI ERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 94.3 94.3 Same SameCleaned and inspected the orifice plate and verified the RTL , the differential and static pressures were calibrated.
TECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY REVIEWED BY
CONTACT DATE DATE 6/30/2015WITNESS SIGNATURE 41TNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/26/2015
c'u^s'âNIERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS) OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:00 PM
TRANSDUCER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL 1833-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,SERIAL# RECALIB DATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016 RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 ""°s"s:D R 0.06 RSSAWOS 0.03 ANALOG RANGE 0-1500 &^fs 14.73 ^"°6 12.36
LIVEDIFFERENTilALFOUND 86.99 LIVEDIFFERENTIIALLEFT 131.16 LIVESTATIC PRESS FOUND 73.51 LIVESTATIC PRESS LEFT 57.97
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.03 -0.01% 0 0 0.18 -0.04% 0
200 200.02 -0.01% 200 250 250.27 -0.05% 250
400 400.57 -0.14% 400 500 500.31 -0.06% 500
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CONITEON Dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometer
E E YES COEANDRINOGN GOOD AS FOUND AS LEFTE ELEED YES BEVERLEDOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
PEDOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMI ERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 94.3 94.3 Same SameCleaned and inspected the orifice plate and verified the RTL , the differential and static pressures were calibrated.
TECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY REVIEWED BY
CONTACT DATE DATE 6/30/2015WITNESS SIGNATURE 41TNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/26/2015
c'u^s'âNIERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEAS) OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:00 PM
TRANSDUCER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATIONEQUIP MODEL#, CRYSTAL 1833-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,SERIAL# RECALIB DATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016 RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 ""°s"s:D R 0.06 RSSAWOS 0.03 ANALOG RANGE 0-1500 &^fs 14.73 ^"°6 12.36
LIVEDIFFERENTilALFOUND 86.99 LIVEDIFFERENTIIALLEFT 131.16 LIVESTATIC PRESS FOUND 73.51 LIVESTATIC PRESS LEFT 57.97
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.03 -0.01% 0 0 0.18 -0.04% 0
200 200.02 -0.01% 200 250 250.27 -0.05% 250
400 400.57 -0.14% 400 500 500.31 -0.06% 500
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CONITEON Dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometer
E E YES COEANDRINOGN GOOD AS FOUND AS LEFTE ELEED YES BEVERLEDOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
PEDOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMI ERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 94.3 94.3 Same SameCleaned and inspected the orifice plate and verified the RTL , the differential and static pressures were calibrated.
TECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY REVIEWED BY
CONTACT DATE DATE 6/30/2015WITNESS SIGNATURE 41TNESS
FORM 9 STATE OF UTAH DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASE DESIGNATION AND SERIAL NUMBER:
SUNDRY NOTICES AND REPORTS ON WELLS
Do not use this form for proposals to drill new wells, Significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILL form for such proposals.
1. TYPE OF WELL OIL WELL D GAS WELL IZI OTHER helium
2. NAME OF OPERATOR:
Flatirons Resources LLC
STATF. CO ZIP 80020 I PHONE NUMBER:
(303) 292-3902 3. ADDRESS OF OPERATOR:
11080 Circle Point Road #18 CITY Westminster
4. LOCATION OF WELL
FOOTAGES AT SURFACE: 1402' FNL 757' FEL
OTRIOTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E
UTU 87659 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
7. UNIT or CA AGREEMENT NAME:
8. WELL NAME and NUMBER:
Flatirons Federal #1-4 9. API NUMBER:
4301950029 10. FIELD AND POOL, OR WILDCAT:
Greater Cisco
COUNTY: Grand
STATE:
UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
D D ACIDIZE D DEEPEN D REPERFORATE CURRENT FORMATION NOTICE OF INTENT
(Submit in Duplicate) D ALTER CASING D FRACTURE TREAT D SIDETRACK TO REPAIR WELL
Approximate date work will start: D CASING REPAIR D NEW CONSTRUCTION D TEMPORARILY ABANDON
D CHANGE TO PREVIOUS PLANS D OPERATOR CHANGE D TUBING REPAIR
D CHANGE TUBING D PLUG AND ABANDON D VENT OR FLARE
IZl SUBSEQUENT REPORT D CHANGE WELL NAME D PLUG BACK D WATER DISPOSAL (Submit Original Form Only)
D CHANGE WELL STATUS D PRODUCTION (STARTIRESUME) D WATER SHUT-OFF Date of work completion:
D COMMINGLE PRODUCING FORMATIONS D RECLAMATION OF WELL SITE IZl OTHER: Calibration Report 9/30/2015 D D CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate and verified the RTD, the differential and static pressures were calibrated
Jeffery E. Jones TITLE
SIGNATURE ------":....r~+l.,-~;L-_+----+---------- DATE
(512000) (See Instruclions on Reverse Side)
RECE\VED OCT 1 3 2015
OIV, OF UIL., GAS & MINING
Managing Director
10/5/2015
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1.TYPEOF\NELL 8.\NELLNAMEandNUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zw 80020 (303) 292-3902 Greater Cisco4 LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:
UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work WIIstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration Report9/30/2015
CONVERT WELLTYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate and verified the RTD, the differential and static pressures were calibrated
RECBVED0CT1 3 2015
D\V.0F0lL,GAS&MINING
SNAME(PLEASE PRINT) TDITE Managing5 Director
(This space for te use
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1.TYPEOF\NELL 8.\NELLNAMEandNUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zw 80020 (303) 292-3902 Greater Cisco4 LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:
UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work WIIstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration Report9/30/2015
CONVERT WELLTYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate and verified the RTD, the differential and static pressures were calibrated
RECBVED0CT1 3 2015
D\V.0F0lL,GAS&MINING
SNAME(PLEASE PRINT) TDITE Managing5 Director
(This space for te use
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zw 80020 (303) 292-3902 Greater Cisco4 LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:
UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work WIIstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration Report9/30/2015
CONVERT WELLTYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate and verified the RTD, the differential and static pressures were calibrated
RECBVED0CT1 3 2015
D\V.0F0lL,GAS&MINING
SNAME(PLEASE PRINT) TDITE Managing5 Director
(This space for te use
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zw 80020 (303) 292-3902 Greater Cisco4 LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:
UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work WIIstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration Report9/30/2015
CONVERT WELLTYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate and verified the RTD, the differential and static pressures were calibrated
RECBVED0CT1 3 2015
D\V.0F0lL,GAS&MINING
SNAME(PLEASE PRINT) TDITE Managing5 Director
(This space for te use
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zw 80020 (303) 292-3902 Greater Cisco4 LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:
UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work WIIstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration Report9/30/2015
CONVERT WELLTYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate and verified the RTD, the differential and static pressures were calibrated
RECBVED0CT1 3 2015
D\V.0F0lL,GAS&MINING
SNAME(PLEASE PRINT) TDITE Managing5 Director
(This space for te use
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zw 80020 (303) 292-3902 Greater Cisco4 LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:
UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work WIIstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration Report9/30/2015
CONVERT WELLTYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate and verified the RTD, the differential and static pressures were calibrated
RECBVED0CT1 3 2015
D\V.0F0lL,GAS&MINING
SNAME(PLEASE PRINT) TDITE Managing5 Director
(This space for te use
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zw 80020 (303) 292-3902 Greater Cisco4 LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:
UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work WIIstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration Report9/30/2015
CONVERT WELLTYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate and verified the RTD, the differential and static pressures were calibrated
RECBVED0CT1 3 2015
D\V.0F0lL,GAS&MINING
SNAME(PLEASE PRINT) TDITE Managing5 Director
(This space for te use
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zw 80020 (303) 292-3902 Greater Cisco4 LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:
UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work WIIstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration Report9/30/2015
CONVERT WELLTYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate and verified the RTD, the differential and static pressures were calibrated
RECBVED0CT1 3 2015
D\V.0F0lL,GAS&MINING
SNAME(PLEASE PRINT) TDITE Managing5 Director
(This space for te use
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zw 80020 (303) 292-3902 Greater Cisco4 LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:
UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work WIIstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration Report9/30/2015
CONVERT WELLTYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate and verified the RTD, the differential and static pressures were calibrated
RECBVED0CT1 3 2015
D\V.0F0lL,GAS&MINING
SNAME(PLEASE PRINT) TDITE Managing5 Director
(This space for te use
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zw 80020 (303) 292-3902 Greater Cisco4 LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:
UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work WIIstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration Report9/30/2015
CONVERT WELLTYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate and verified the RTD, the differential and static pressures were calibrated
RECBVED0CT1 3 2015
D\V.0F0lL,GAS&MINING
SNAME(PLEASE PRINT) TDITE Managing5 Director
(This space for te use
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zw 80020 (303) 292-3902 Greater Cisco4 LOCATIONOF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:
UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work WIIstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration Report9/30/2015
CONVERT WELLTYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate and verified the RTD, the differential and static pressures were calibrated
RECBVED0CT1 3 2015
D\V.0F0lL,GAS&MINING
SNAME(PLEASE PRINT) TDITE Managing5 Director
(This space for te use
(5/2000) (See Instructions on Reverse
nr Services
Production Management Measurement, Analytical, Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492
P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORT LOCATION NO.
STATION OR
CUSTOMER
GPS LOCATION
LEAK TEST
TRANSDUCER
TYPE
OK
100 COUNrY GRAND STATE 9/30/2015
Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP
N 3911. 221'.0" LOGITUOE
LIVE DIFFERENTIIAL FOUND -0.01 LIVE DIFFERENTIIAL LEFT 0.00 LIVE STATIC PRESS FOUND 106.82 LIVE STATIC PRESS LEFT 106.70
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
o -0.02 0.01% o o -0.06 0.01% o 200 199.95 0.01% 200 250 249.94 0.01% 250
400 399.77 0.06% 400 500 499.86 0.03% 500
Do not drive RTD if flowing temp. is + or- 0.5 degrees of test thermometer
YES GOOD AS FOUND AS LEFT
YES YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
#DIV/Ol
#DIV/Ol
SERIAL #
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 93.6 93.3 Same Same
the RTD, the differential and static pressures were calibrated.
RECEIVED OCT 1 3 2015
D/V. or- OIL, GAS & M
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 couart GRAND STATE UTAH DATE 9/30/2015
CTAT NORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 (EDEsg UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPO
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL# CRYSTAL1$33-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,
SERIAL# RECALIBDATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 "°s"sNUD R-0.01
"°,^s's^o-0.02 ANALOG 1 RANGE 0-1500 ,"RASS 14.73 ^" 12.36
LIVEDIFFERENTIIALFOUND -0.01 LIVEDIFFERENTIIALLEFT 0.00 LIVESTATICPRESS FOUND 106.82 LIVESTATICPRESS LEFT 106.70
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.02 0.01% 0 0 -0.06 0.01% 0
200 199.95 0.01% 200 250 249.94 0.01% 250
400 399.77 0.06% 400 500 499.86 0.03% 500
ORIFICEPLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CON ITON Dirty Do not drive RTD ifflowinqtemp. is + or- 0.5 degrees of test thermometersEDGEs, YES cŠDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
AMPOSOR 0.625 MICSIZE NA #DIVIO!
ORIFICEFITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINETEMFERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 93.6 93.3 Same SameCleaned and inspected the orifice plate and verified the RTC, the differential and static pressures were calibrated.
RECEWED0CT13205
DN.0F0/L, GAS&MININGTECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY
MOENTD REVIEWEDBY
CONTACT DATE DATE 10/4/2015
WITNESS SIGNATURE MITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 couart GRAND STATE UTAH DATE 9/30/2015
CTAT NORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 (EDEsg UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPO
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL# CRYSTAL1$33-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,
SERIAL# RECALIBDATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 "°s"sNUD R-0.01
"°,^s's^o-0.02 ANALOG 1 RANGE 0-1500 ,"RASS 14.73 ^" 12.36
LIVEDIFFERENTIIALFOUND -0.01 LIVEDIFFERENTIIALLEFT 0.00 LIVESTATICPRESS FOUND 106.82 LIVESTATICPRESS LEFT 106.70
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.02 0.01% 0 0 -0.06 0.01% 0
200 199.95 0.01% 200 250 249.94 0.01% 250
400 399.77 0.06% 400 500 499.86 0.03% 500
ORIFICEPLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CON ITON Dirty Do not drive RTD ifflowinqtemp. is + or- 0.5 degrees of test thermometersEDGEs, YES cŠDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
AMPOSOR 0.625 MICSIZE NA #DIVIO!
ORIFICEFITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINETEMFERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 93.6 93.3 Same SameCleaned and inspected the orifice plate and verified the RTC, the differential and static pressures were calibrated.
RECEWED0CT13205
DN.0F0/L, GAS&MININGTECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY
MOENTD REVIEWEDBY
CONTACT DATE DATE 10/4/2015
WITNESS SIGNATURE MITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 couart GRAND STATE UTAH DATE 9/30/2015
CTAT NORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 (EDEsg UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPO
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL# CRYSTAL1$33-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,
SERIAL# RECALIBDATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 "°s"sNUD R-0.01
"°,^s's^o-0.02 ANALOG 1 RANGE 0-1500 ,"RASS 14.73 ^" 12.36
LIVEDIFFERENTIIALFOUND -0.01 LIVEDIFFERENTIIALLEFT 0.00 LIVESTATICPRESS FOUND 106.82 LIVESTATICPRESS LEFT 106.70
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.02 0.01% 0 0 -0.06 0.01% 0
200 199.95 0.01% 200 250 249.94 0.01% 250
400 399.77 0.06% 400 500 499.86 0.03% 500
ORIFICEPLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CON ITON Dirty Do not drive RTD ifflowinqtemp. is + or- 0.5 degrees of test thermometersEDGEs, YES cŠDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
AMPOSOR 0.625 MICSIZE NA #DIVIO!
ORIFICEFITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINETEMFERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 93.6 93.3 Same SameCleaned and inspected the orifice plate and verified the RTC, the differential and static pressures were calibrated.
RECEWED0CT13205
DN.0F0/L, GAS&MININGTECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY
MOENTD REVIEWEDBY
CONTACT DATE DATE 10/4/2015
WITNESS SIGNATURE MITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 couart GRAND STATE UTAH DATE 9/30/2015
CTAT NORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 (EDEsg UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPO
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL# CRYSTAL1$33-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,
SERIAL# RECALIBDATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 "°s"sNUD R-0.01
"°,^s's^o-0.02 ANALOG 1 RANGE 0-1500 ,"RASS 14.73 ^" 12.36
LIVEDIFFERENTIIALFOUND -0.01 LIVEDIFFERENTIIALLEFT 0.00 LIVESTATICPRESS FOUND 106.82 LIVESTATICPRESS LEFT 106.70
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.02 0.01% 0 0 -0.06 0.01% 0
200 199.95 0.01% 200 250 249.94 0.01% 250
400 399.77 0.06% 400 500 499.86 0.03% 500
ORIFICEPLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CON ITON Dirty Do not drive RTD ifflowinqtemp. is + or- 0.5 degrees of test thermometersEDGEs, YES cŠDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
AMPOSOR 0.625 MICSIZE NA #DIVIO!
ORIFICEFITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINETEMFERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 93.6 93.3 Same SameCleaned and inspected the orifice plate and verified the RTC, the differential and static pressures were calibrated.
RECEWED0CT13205
DN.0F0/L, GAS&MININGTECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY
MOENTD REVIEWEDBY
CONTACT DATE DATE 10/4/2015
WITNESS SIGNATURE MITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 couart GRAND STATE UTAH DATE 9/30/2015
CTAT NORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 (EDEsg UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPO
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL# CRYSTAL1$33-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,
SERIAL# RECALIBDATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 "°s"sNUD R-0.01
"°,^s's^o-0.02 ANALOG 1 RANGE 0-1500 ,"RASS 14.73 ^" 12.36
LIVEDIFFERENTIIALFOUND -0.01 LIVEDIFFERENTIIALLEFT 0.00 LIVESTATICPRESS FOUND 106.82 LIVESTATICPRESS LEFT 106.70
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.02 0.01% 0 0 -0.06 0.01% 0
200 199.95 0.01% 200 250 249.94 0.01% 250
400 399.77 0.06% 400 500 499.86 0.03% 500
ORIFICEPLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CON ITON Dirty Do not drive RTD ifflowinqtemp. is + or- 0.5 degrees of test thermometersEDGEs, YES cŠDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
AMPOSOR 0.625 MICSIZE NA #DIVIO!
ORIFICEFITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINETEMFERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 93.6 93.3 Same SameCleaned and inspected the orifice plate and verified the RTC, the differential and static pressures were calibrated.
RECEWED0CT13205
DN.0F0/L, GAS&MININGTECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY
MOENTD REVIEWEDBY
CONTACT DATE DATE 10/4/2015
WITNESS SIGNATURE MITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 couart GRAND STATE UTAH DATE 9/30/2015
CTAT NORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 (EDEsg UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPO
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL# CRYSTAL1$33-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,
SERIAL# RECALIBDATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 "°s"sNUD R-0.01
"°,^s's^o-0.02 ANALOG 1 RANGE 0-1500 ,"RASS 14.73 ^" 12.36
LIVEDIFFERENTIIALFOUND -0.01 LIVEDIFFERENTIIALLEFT 0.00 LIVESTATICPRESS FOUND 106.82 LIVESTATICPRESS LEFT 106.70
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.02 0.01% 0 0 -0.06 0.01% 0
200 199.95 0.01% 200 250 249.94 0.01% 250
400 399.77 0.06% 400 500 499.86 0.03% 500
ORIFICEPLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CON ITON Dirty Do not drive RTD ifflowinqtemp. is + or- 0.5 degrees of test thermometersEDGEs, YES cŠDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
AMPOSOR 0.625 MICSIZE NA #DIVIO!
ORIFICEFITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINETEMFERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 93.6 93.3 Same SameCleaned and inspected the orifice plate and verified the RTC, the differential and static pressures were calibrated.
RECEWED0CT13205
DN.0F0/L, GAS&MININGTECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY
MOENTD REVIEWEDBY
CONTACT DATE DATE 10/4/2015
WITNESS SIGNATURE MITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 couart GRAND STATE UTAH DATE 9/30/2015
CTAT NORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 (EDEsg UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPO
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL# CRYSTAL1$33-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,
SERIAL# RECALIBDATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 "°s"sNUD R-0.01
"°,^s's^o-0.02 ANALOG 1 RANGE 0-1500 ,"RASS 14.73 ^" 12.36
LIVEDIFFERENTIIALFOUND -0.01 LIVEDIFFERENTIIALLEFT 0.00 LIVESTATICPRESS FOUND 106.82 LIVESTATICPRESS LEFT 106.70
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.02 0.01% 0 0 -0.06 0.01% 0
200 199.95 0.01% 200 250 249.94 0.01% 250
400 399.77 0.06% 400 500 499.86 0.03% 500
ORIFICEPLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CON ITON Dirty Do not drive RTD ifflowinqtemp. is + or- 0.5 degrees of test thermometersEDGEs, YES cŠDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
AMPOSOR 0.625 MICSIZE NA #DIVIO!
ORIFICEFITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINETEMFERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 93.6 93.3 Same SameCleaned and inspected the orifice plate and verified the RTC, the differential and static pressures were calibrated.
RECEWED0CT13205
DN.0F0/L, GAS&MININGTECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY
MOENTD REVIEWEDBY
CONTACT DATE DATE 10/4/2015
WITNESS SIGNATURE MITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 couart GRAND STATE UTAH DATE 9/30/2015
CTAT NORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 (EDEsg UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPO
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL# CRYSTAL1$33-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,
SERIAL# RECALIBDATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 "°s"sNUD R-0.01
"°,^s's^o-0.02 ANALOG 1 RANGE 0-1500 ,"RASS 14.73 ^" 12.36
LIVEDIFFERENTIIALFOUND -0.01 LIVEDIFFERENTIIALLEFT 0.00 LIVESTATICPRESS FOUND 106.82 LIVESTATICPRESS LEFT 106.70
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.02 0.01% 0 0 -0.06 0.01% 0
200 199.95 0.01% 200 250 249.94 0.01% 250
400 399.77 0.06% 400 500 499.86 0.03% 500
ORIFICEPLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CON ITON Dirty Do not drive RTD ifflowinqtemp. is + or- 0.5 degrees of test thermometersEDGEs, YES cŠDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
AMPOSOR 0.625 MICSIZE NA #DIVIO!
ORIFICEFITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINETEMFERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 93.6 93.3 Same SameCleaned and inspected the orifice plate and verified the RTC, the differential and static pressures were calibrated.
RECEWED0CT13205
DN.0F0/L, GAS&MININGTECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY
MOENTD REVIEWEDBY
CONTACT DATE DATE 10/4/2015
WITNESS SIGNATURE MITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 couart GRAND STATE UTAH DATE 9/30/2015
CTAT NORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 (EDEsg UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPO
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL# CRYSTAL1$33-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,
SERIAL# RECALIBDATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 "°s"sNUD R-0.01
"°,^s's^o-0.02 ANALOG 1 RANGE 0-1500 ,"RASS 14.73 ^" 12.36
LIVEDIFFERENTIIALFOUND -0.01 LIVEDIFFERENTIIALLEFT 0.00 LIVESTATICPRESS FOUND 106.82 LIVESTATICPRESS LEFT 106.70
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.02 0.01% 0 0 -0.06 0.01% 0
200 199.95 0.01% 200 250 249.94 0.01% 250
400 399.77 0.06% 400 500 499.86 0.03% 500
ORIFICEPLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CON ITON Dirty Do not drive RTD ifflowinqtemp. is + or- 0.5 degrees of test thermometersEDGEs, YES cŠDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
AMPOSOR 0.625 MICSIZE NA #DIVIO!
ORIFICEFITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINETEMFERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 93.6 93.3 Same SameCleaned and inspected the orifice plate and verified the RTC, the differential and static pressures were calibrated.
RECEWED0CT13205
DN.0F0/L, GAS&MININGTECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY
MOENTD REVIEWEDBY
CONTACT DATE DATE 10/4/2015
WITNESS SIGNATURE MITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 couart GRAND STATE UTAH DATE 9/30/2015
CTAT NORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 (EDEsg UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPO
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL# CRYSTAL1$33-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,
SERIAL# RECALIBDATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 "°s"sNUD R-0.01
"°,^s's^o-0.02 ANALOG 1 RANGE 0-1500 ,"RASS 14.73 ^" 12.36
LIVEDIFFERENTIIALFOUND -0.01 LIVEDIFFERENTIIALLEFT 0.00 LIVESTATICPRESS FOUND 106.82 LIVESTATICPRESS LEFT 106.70
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.02 0.01% 0 0 -0.06 0.01% 0
200 199.95 0.01% 200 250 249.94 0.01% 250
400 399.77 0.06% 400 500 499.86 0.03% 500
ORIFICEPLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CON ITON Dirty Do not drive RTD ifflowinqtemp. is + or- 0.5 degrees of test thermometersEDGEs, YES cŠDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
AMPOSOR 0.625 MICSIZE NA #DIVIO!
ORIFICEFITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINETEMFERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 93.6 93.3 Same SameCleaned and inspected the orifice plate and verified the RTC, the differential and static pressures were calibrated.
RECEWED0CT13205
DN.0F0/L, GAS&MININGTECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY
MOENTD REVIEWEDBY
CONTACT DATE DATE 10/4/2015
WITNESS SIGNATURE MITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 couart GRAND STATE UTAH DATE 9/30/2015
CTAT NORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 (EDEsg UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPO
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL# CRYSTAL1$33-36/3000 PSI, S/N 2262-840542, THERMOPROBE TL-1W, S/N 1-5710, PIE, MODEL211, SERIAL 109653,
SERIAL# RECALIBDATE PRESS DUE DATE 04/14/2016 TEMP DUE DATE4/14/2016RTD DUE 04/13/2016
ANALOG 0 RANGE 0-400 "°s"sNUD R-0.01
"°,^s's^o-0.02 ANALOG 1 RANGE 0-1500 ,"RASS 14.73 ^" 12.36
LIVEDIFFERENTIIALFOUND -0.01 LIVEDIFFERENTIIALLEFT 0.00 LIVESTATICPRESS FOUND 106.82 LIVESTATICPRESS LEFT 106.70
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.02 0.01% 0 0 -0.06 0.01% 0
200 199.95 0.01% 200 250 249.94 0.01% 250
400 399.77 0.06% 400 500 499.86 0.03% 500
ORIFICEPLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 RANGE 0-150
CON ITON Dirty Do not drive RTD ifflowinqtemp. is + or- 0.5 degrees of test thermometersEDGEs, YES cŠDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
AMPOSOR 0.625 MICSIZE NA #DIVIO!
ORIFICEFITTING #DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINETEMFERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 93.6 93.3 Same SameCleaned and inspected the orifice plate and verified the RTC, the differential and static pressures were calibrated.
RECEWED0CT13205
DN.0F0/L, GAS&MININGTECHNICIANSIGNATURE
WITNESS Ni)TIFICATION REVIEWCOMPANY
MOENTD REVIEWEDBY
CONTACT DATE DATE 10/4/2015
WITNESS SIGNATURE MITNESS
STATE OF UTAH DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING
,.., ..
RECEIVED DEC 1 0 2015
SUNDRY NOTICES AND REPORTS 'ON VVEllt.SAs & MINING
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPliCATION FOR PERMIT TO DRILL form for such proposals.
1. TYPE OF WELL OIL WELL 0 GAS WELL 0 OTHER ...:..:h:.;:e.:..:.liu=.:m..:..:..-________ _
2. NAME OF OPERATOR:
Flatirons Resources LLC
STATE CO ZIP80020 I PHONE NUMBER:
(303) 292-3902
3. AODRESS OF OPERATOR:
11080 Circle Point Road #18' CITY Westminster
4. LOCATION OF WELL
FOOTAGES AT SURFACE: ;1~ __ :·f\B.' •• ~.,.~ ... !it;i:Cy~j;;.
OTR/OTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: "'(;' i~l~j
FORM 9
5. lEASE DESIGNATION AND SERIAL NUMBER:
UTU87659
6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
7. UNIT or CA AGREEMENT NAME:
8. WELL NAME and NUMBER:
Flatirons Federal #1-4
9. API NUMBER:
4301950029
10. FIELD AND POOL, OR WILDCAT:
Greater Cisco
STATE:
UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
0 0 ACIDIZE 0 DEEPEN 0 REPERFORATE CURRENT FORMATION NOTICE OF INTENT
(Submit in Duplicate) 0 ALTER CASING 0 FRACTURE TREAT 0 SIDETRACK TO REPAIR WELL
Approximate date work will start: 0 CASING REPAIR 0 NEW CONSTRUCTION 0 TEMPORARILY ABANDON
0 CHANGE TO PREVIOUS PlANS 0 OPERATOR CHANGE 0 TUBING REPAIR
0 CHANGE TUBING 0 PLUG AND ABANDON 0 VENT OR FLARE
III SUBSEQUENT REPORT 0 CHANGE WELL NAME 0 PLUG BACK 0 WATER DISPOSAL (Subm~ Original Form Only)
0 CHANGE WELL STATUS 0 PRODUCTION (STARTIRESUME) 0 WATER SHUT -OFF Date of work completion:
0 COMMINGLE PRODUCING FORMATIONS 0 RECLAMATION OF WELL SITE III OTHER: Electronic Flow 12/2/2015 0 0 Measurement Report CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate - it was hydrated and iced over creating a smaller orifice size and high differential.
Calibrated the differential and static pressures and verified temperatures.
Jeffery E. Jones TITLE Managing Director
DATE 12/9/2015
(This space fo _~-:::-"""
(5/2000) (See Instructions on Reverse Side)
STATE OF UTAHRECEWED FORM 9
DEPARTMENT OF NATURALRESOURCES DEC10DIVISIONOF OIL, GAS AND MINING 2015 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU87659
SUNDRY NOTICES AND REPORTS S&MINING 6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITor CA AGREEMENT NAME:Do not use thisform for proposals to drillnewwells,significantlydeepen existing wells below currentbottom-hole depth, reenterplugged wells, or to
drill horizontal laterals. UseAPPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL • 8. WELL NAMEand NUMBER:OIL WELL GAS WELL OTHER helium Flatirons Federal #1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGES AT SURFACE 1402' FNL 78T FEL Sec 4, T198, R25E COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
19. CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONO NOTICE OF INTENT(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart CASING REPAIR O NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) O WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELLSITE OTHER: Electronic Flow12/2/2015
CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Measurement Report
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate - it was hydrated and iced over creating a smaller orifice size and high differential.Calibrated the differential and static pressures and verified temperatures.
NAME(PLEASE PRINT) TDITE Managing5Director
(This space fo e ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAHRECEWED FORM 9
DEPARTMENT OF NATURALRESOURCES DEC10DIVISIONOF OIL, GAS AND MINING 2015 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU87659
SUNDRY NOTICES AND REPORTS S&MINING 6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITor CA AGREEMENT NAME:Do not use thisform for proposals to drillnewwells,significantlydeepen existing wells below currentbottom-hole depth, reenterplugged wells, or to
drill horizontal laterals. UseAPPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL OTHER helium Flatirons Federal #1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGES AT SURFACE 1402' FNL 78T FEL Sec 4, T198, R25E COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
19. CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONO NOTICE OF INTENT(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart CASING REPAIR O NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) O WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELLSITE OTHER: Electronic Flow12/2/2015
CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Measurement Report
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate - it was hydrated and iced over creating a smaller orifice size and high differential.Calibrated the differential and static pressures and verified temperatures.
NAME(PLEASE PRINT) TDITE Managing5Director
(This space fo e ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAHRECEWED FORM 9
DEPARTMENT OF NATURALRESOURCES DEC10DIVISIONOF OIL, GAS AND MINING 2015 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU87659
SUNDRY NOTICES AND REPORTS S&MINING 6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITor CA AGREEMENT NAME:Do not use thisform for proposals to drillnewwells,significantlydeepen existing wells below currentbottom-hole depth, reenterplugged wells, or to
drill horizontal laterals. UseAPPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL OTHER helium Flatirons Federal #1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGES AT SURFACE 1402' FNL 78T FEL Sec 4, T198, R25E COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
19. CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONO NOTICE OF INTENT(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart CASING REPAIR O NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) O WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELLSITE OTHER: Electronic Flow12/2/2015
CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Measurement Report
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate - it was hydrated and iced over creating a smaller orifice size and high differential.Calibrated the differential and static pressures and verified temperatures.
NAME(PLEASE PRINT) TDITE Managing5Director
(This space fo e ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAHRECEWED FORM 9
DEPARTMENT OF NATURALRESOURCES DEC10DIVISIONOF OIL, GAS AND MINING 2015 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU87659
SUNDRY NOTICES AND REPORTS S&MINING 6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITor CA AGREEMENT NAME:Do not use thisform for proposals to drillnewwells,significantlydeepen existing wells below currentbottom-hole depth, reenterplugged wells, or to
drill horizontal laterals. UseAPPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL OTHER helium Flatirons Federal #1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGES AT SURFACE 1402' FNL 78T FEL Sec 4, T198, R25E COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
19. CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONO NOTICE OF INTENT(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart CASING REPAIR O NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) O WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELLSITE OTHER: Electronic Flow12/2/2015
CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Measurement Report
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate - it was hydrated and iced over creating a smaller orifice size and high differential.Calibrated the differential and static pressures and verified temperatures.
NAME(PLEASE PRINT) TDITE Managing5Director
(This space fo e ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAHRECEWED FORM 9
DEPARTMENT OF NATURALRESOURCES DEC10DIVISIONOF OIL, GAS AND MINING 2015 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU87659
SUNDRY NOTICES AND REPORTS S&MINING 6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITor CA AGREEMENT NAME:Do not use thisform for proposals to drillnewwells,significantlydeepen existing wells below currentbottom-hole depth, reenterplugged wells, or to
drill horizontal laterals. UseAPPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL OTHER helium Flatirons Federal #1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGES AT SURFACE 1402' FNL 78T FEL Sec 4, T198, R25E COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
19. CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONO NOTICE OF INTENT(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart CASING REPAIR O NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) O WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELLSITE OTHER: Electronic Flow12/2/2015
CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Measurement Report
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate - it was hydrated and iced over creating a smaller orifice size and high differential.Calibrated the differential and static pressures and verified temperatures.
NAME(PLEASE PRINT) TDITE Managing5Director
(This space fo e ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAHRECEWED FORM 9
DEPARTMENT OF NATURALRESOURCES DEC10DIVISIONOF OIL, GAS AND MINING 2015 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU87659
SUNDRY NOTICES AND REPORTS S&MINING 6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITor CA AGREEMENT NAME:Do not use thisform for proposals to drillnewwells,significantlydeepen existing wells below currentbottom-hole depth, reenterplugged wells, or to
drill horizontal laterals. UseAPPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL OTHER helium Flatirons Federal #1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGES AT SURFACE 1402' FNL 78T FEL Sec 4, T198, R25E COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
19. CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONO NOTICE OF INTENT(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart CASING REPAIR O NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) O WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELLSITE OTHER: Electronic Flow12/2/2015
CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Measurement Report
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate - it was hydrated and iced over creating a smaller orifice size and high differential.Calibrated the differential and static pressures and verified temperatures.
NAME(PLEASE PRINT) TDITE Managing5Director
(This space fo e ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAHRECEWED FORM 9
DEPARTMENT OF NATURALRESOURCES DEC10DIVISIONOF OIL, GAS AND MINING 2015 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU87659
SUNDRY NOTICES AND REPORTS S&MINING 6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITor CA AGREEMENT NAME:Do not use thisform for proposals to drillnewwells,significantlydeepen existing wells below currentbottom-hole depth, reenterplugged wells, or to
drill horizontal laterals. UseAPPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL OTHER helium Flatirons Federal #1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGES AT SURFACE 1402' FNL 78T FEL Sec 4, T198, R25E COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
19. CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONO NOTICE OF INTENT(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart CASING REPAIR O NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) O WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELLSITE OTHER: Electronic Flow12/2/2015
CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Measurement Report
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate - it was hydrated and iced over creating a smaller orifice size and high differential.Calibrated the differential and static pressures and verified temperatures.
NAME(PLEASE PRINT) TDITE Managing5Director
(This space fo e ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAHRECEWED FORM 9
DEPARTMENT OF NATURALRESOURCES DEC10DIVISIONOF OIL, GAS AND MINING 2015 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU87659
SUNDRY NOTICES AND REPORTS S&MINING 6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITor CA AGREEMENT NAME:Do not use thisform for proposals to drillnewwells,significantlydeepen existing wells below currentbottom-hole depth, reenterplugged wells, or to
drill horizontal laterals. UseAPPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL OTHER helium Flatirons Federal #1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGES AT SURFACE 1402' FNL 78T FEL Sec 4, T198, R25E COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
19. CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONO NOTICE OF INTENT(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart CASING REPAIR O NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) O WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELLSITE OTHER: Electronic Flow12/2/2015
CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Measurement Report
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate - it was hydrated and iced over creating a smaller orifice size and high differential.Calibrated the differential and static pressures and verified temperatures.
NAME(PLEASE PRINT) TDITE Managing5Director
(This space fo e ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAHRECEWED FORM 9
DEPARTMENT OF NATURALRESOURCES DEC10DIVISIONOF OIL, GAS AND MINING 2015 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU87659
SUNDRY NOTICES AND REPORTS S&MINING 6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITor CA AGREEMENT NAME:Do not use thisform for proposals to drillnewwells,significantlydeepen existing wells below currentbottom-hole depth, reenterplugged wells, or to
drill horizontal laterals. UseAPPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL OTHER helium Flatirons Federal #1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGES AT SURFACE 1402' FNL 78T FEL Sec 4, T198, R25E COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
19. CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONO NOTICE OF INTENT(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart CASING REPAIR O NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) O WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELLSITE OTHER: Electronic Flow12/2/2015
CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Measurement Report
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate - it was hydrated and iced over creating a smaller orifice size and high differential.Calibrated the differential and static pressures and verified temperatures.
NAME(PLEASE PRINT) TDITE Managing5Director
(This space fo e ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAHRECEWED FORM 9
DEPARTMENT OF NATURALRESOURCES DEC10DIVISIONOF OIL, GAS AND MINING 2015 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU87659
SUNDRY NOTICES AND REPORTS S&MINING 6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNITor CA AGREEMENT NAME:Do not use thisform for proposals to drillnewwells,significantlydeepen existing wells below currentbottom-hole depth, reenterplugged wells, or to
drill horizontal laterals. UseAPPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL GAS WELL OTHER helium Flatirons Federal #1-4
2. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 CITY Westminster STATE CO zi,80020 (303) 292-3902 Greater Cisco4. LOCATIONOF WELL
FOOTAGES AT SURFACE 1402' FNL 78T FEL Sec 4, T198, R25E COUNTY: Grand
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
19. CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONO NOTICE OF INTENT(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart CASING REPAIR O NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) O WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELLSITE OTHER: Electronic Flow12/2/2015
CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION Measurement Report
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected the orifice plate - it was hydrated and iced over creating a smaller orifice size and high differential.Calibrated the differential and static pressures and verified temperatures.
NAME(PLEASE PRINT) TDITE Managing5Director
(This space fo e ly)
(5/2000) (See Instructions on Reverse
nr Services
Production Management
Measurement, Analytical, RECEIVED Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P·9EC 1 0 201 BOX 3866 Grand Junction, CO 81501 5
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT D"~1MJTI9M ~J;P.PRT LOCATION NO. 100 COUNTY GRAND STATE UTAH DATE 12/2/2lW~ STATION OR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP I 21 FEDERAL I UTU87659 API 430-195-002-90000 CUSTOMER LEASE #
GPS LOCATION LATITUDE N 3911 . 221'.0" LOGITUDE W 1098.858" I ELEVATION 4955
LEAK OK I
PASSED X I NOT PASSED I
REPAIRED I NOT REPAIRED TIME OF TEST 11:00 AM TEST
TRANSDUCER WEATHERFORD CIM MVT FLOW 0 SERIAL # S7138083JNC TYPE COMPUTER
CALIBRATION EQUIP MODEL#. II CRYSTAL MODEL IS331613000psi, SERIAL TEMP
THERMOPROBE MODEL TL-1W, SERIAL RTD
ALETKSERIES 11, SERIAL 161092 SERIAL#. RECALIB DATE PRESS 2564-144532 DUE 6-17-16 1-5802, DUE 6-18-1 6 DUE 6-17-16
;. :. DIFFE8t;~TIALJESr)·ii' . . ... ,' . ,·c .. ' .. ~··· .•• )§TATI~.t(E;§I:.';Ai{i;~i:::' ·:,{::t~·.:!,:.·\~~: •....• .. , ..... :-.
ANALOG 0 RANGE 0-400 ZERO UNDER -0.01
ZERO AT ATMOS 0.06 ANALOG 1 RANGE 0-1500 BASE 14.73 ATMOS 12.36 PRESSURE PRESSURE PRESS PRESS
LIVE DIFFERENTIIAL FOUND 236.60 LIVE DIFFERENTIIAL LEFT 169.40 LIVE STATIC PRESS FOUND 34.10 LIVE STATIC PRESS LEFT 30.60
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.06 -0.02% 0 0 0.00 0.00% 0
200 199.88 0.03% 200 250 249.85 0.03% 250
400 399.67 0.08% 400 500 499.55 0.09% 500
IP ,. 'pc' ORIFICE.t?LA TE :" ....... ,.:." L· 'J1!~;tEMPERATlJRE TEST2·';~:)/::. , .... ,' .. ..... , ..
SIZE 2 X 0.625 BETA RATIO 0.3125 ANALOG 3 RANGE 0-150 PLATE Hydrates on plate Do not drive RTD if flowing temp. is + or- 0.5 degrees of test thenmometer CONDITION . EDGES YES SEAL RING GOOD AS FOUND AS LEFT SHARP? CONDITION
BEVELED YES BEVEL DOWN YES DEVICE FLOW COMPUTER % ERROR PLATE? STREAM? FLOW COMPUTER
STAMPED OR 0.625 MICSIZE NA #DIV/O! t,EASUREO SIZE
')1 ORIFICE FITTING ",:') ,.
#DIV/O!
SIZE 2.067 I TYPE DANIEL STATIC TAP US #DIV/O!
SERIAL # 13180234 METER 2.067 " '.;;,}' .... LINE TEMRJ:RATURl$r~ ~;-:;;l;~':;, .'. ';:":":.' :.:. TUBEID " .., ... "
AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 30.4 30.5 Same Same
Cleaned and inspected the orifice plate it was hydrated and iced over creating a smaller orifice size and high differential. Calibrated the differential and static pressures and verified temperature.
TECHNICIAN SIGNATURE 5_li.g~
• ;~, .·:<·'··:·.·;','D:i;.:~,;·~'k~!l~:·;.·~':i,~\~j;;~,!TNF~~~O'tIE~4.TlPB;.s~?i.~&f~;;r.~~~L;f~i'iffjIlUJ; .'ii'~·~·~WI':\AI ;:li!li;:!,<~''; ;
COMPANY BLM CONTACT Phone message REVIEWED BY J.e~ METHOD
CONTACT Jeff Brown DATE 11/30/2015 DATE 121712015
WITNESS SIGNATURE NITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENTCAURTION RRORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 12/2Ì201$
c'u^S'TONIEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 TEDAES UTU87659 API 430-195-002-90000
GPS LOCATION LAT1TUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
ANALOG 0 RANGE 0-400 is"sNUD R-0.01
ma Amos 0.06 ANALOG RANGE 0-1500 s^s 14.73 ^"s" 12.36
LIVEDIFFERENTIIALFOUND 236.60 LIVEDIFFERENTilAL LEFT 169.40 LIVESTATIC PRESS FOUND 34.10 LIVESTATIC PRESS LEFT 30.60AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.06 -0.02% 0 0 0.00 0.00% 0
200 199.88 0.03% 200 250 249.85 0.03% 250400 399.67 0.08% 400 500 499.55 0.09% 500
OR ggg ' " TEMSIZE 2 X 0.625 BETA RATIo 0.3125 ANALOG 3 RANGE 0-150
CON T ON Hydrates on plate Do not drive RTD if flowing temp. is + or- 0.5 degrees of test thermometerE E YES coÌDIRINOGN GOOD AS FOUND AS LEFT
ELEED YES BEVERL WN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
#DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!
SERIAL# 13180234 ,MeETEERD 2.067 igggg $¾ REAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKs 30.4 30.5 Same SameCleaned and inspected the orifice plate it was hydrated and ced over creat ng a smaller o ifice size and b ghdifferential. Calibrated the differential and static pressures and verified temperature.
TECHNICIANSIGNATURE
COMPANY BLM CMENTHAOCD' Phone message REVIEWED BY
CONTACT Jeff BrOWO DATE 11/30/2015 DATE 12/7/2015WITNESS SIGNATURE NITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENTCAURTION RRORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 12/2Ì201$
c'u^S'TONIEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 TEDAES UTU87659 API 430-195-002-90000
GPS LOCATION LAT1TUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
ANALOG 0 RANGE 0-400 is"sNUD R-0.01
ma Amos 0.06 ANALOG RANGE 0-1500 s^s 14.73 ^"s" 12.36
LIVEDIFFERENTIIALFOUND 236.60 LIVEDIFFERENTilAL LEFT 169.40 LIVESTATIC PRESS FOUND 34.10 LIVESTATIC PRESS LEFT 30.60AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.06 -0.02% 0 0 0.00 0.00% 0
200 199.88 0.03% 200 250 249.85 0.03% 250400 399.67 0.08% 400 500 499.55 0.09% 500
OR ggg ' " TEMSIZE 2 X 0.625 BETA RATIo 0.3125 ANALOG 3 RANGE 0-150
CON T ON Hydrates on plate Do not drive RTD if flowing temp. is + or- 0.5 degrees of test thermometerE E YES coÌDIRINOGN GOOD AS FOUND AS LEFT
ELEED YES BEVERL WN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
#DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!
SERIAL# 13180234 ,MeETEERD 2.067 igggg $¾ REAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKs 30.4 30.5 Same SameCleaned and inspected the orifice plate it was hydrated and ced over creat ng a smaller o ifice size and b ghdifferential. Calibrated the differential and static pressures and verified temperature.
TECHNICIANSIGNATURE
COMPANY BLM CMENTHAOCD' Phone message REVIEWED BY
CONTACT Jeff BrOWO DATE 11/30/2015 DATE 12/7/2015WITNESS SIGNATURE NITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENTCAURTION RRORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 12/2Ì201$
c'u^S'TONIEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 TEDAES UTU87659 API 430-195-002-90000
GPS LOCATION LAT1TUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
ANALOG 0 RANGE 0-400 is"sNUD R-0.01
ma Amos 0.06 ANALOG RANGE 0-1500 s^s 14.73 ^"s" 12.36
LIVEDIFFERENTIIALFOUND 236.60 LIVEDIFFERENTilAL LEFT 169.40 LIVESTATIC PRESS FOUND 34.10 LIVESTATIC PRESS LEFT 30.60AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.06 -0.02% 0 0 0.00 0.00% 0
200 199.88 0.03% 200 250 249.85 0.03% 250400 399.67 0.08% 400 500 499.55 0.09% 500
OR ggg ' " TEMSIZE 2 X 0.625 BETA RATIo 0.3125 ANALOG 3 RANGE 0-150
CON T ON Hydrates on plate Do not drive RTD if flowing temp. is + or- 0.5 degrees of test thermometerE E YES coÌDIRINOGN GOOD AS FOUND AS LEFT
ELEED YES BEVERL WN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
#DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!
SERIAL# 13180234 ,MeETEERD 2.067 igggg $¾ REAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKs 30.4 30.5 Same SameCleaned and inspected the orifice plate it was hydrated and ced over creat ng a smaller o ifice size and b ghdifferential. Calibrated the differential and static pressures and verified temperature.
TECHNICIANSIGNATURE
COMPANY BLM CMENTHAOCD' Phone message REVIEWED BY
CONTACT Jeff BrOWO DATE 11/30/2015 DATE 12/7/2015WITNESS SIGNATURE NITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENTCAURTION RRORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 12/2Ì201$
c'u^S'TONIEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 TEDAES UTU87659 API 430-195-002-90000
GPS LOCATION LAT1TUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
ANALOG 0 RANGE 0-400 is"sNUD R-0.01
ma Amos 0.06 ANALOG RANGE 0-1500 s^s 14.73 ^"s" 12.36
LIVEDIFFERENTIIALFOUND 236.60 LIVEDIFFERENTilAL LEFT 169.40 LIVESTATIC PRESS FOUND 34.10 LIVESTATIC PRESS LEFT 30.60AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.06 -0.02% 0 0 0.00 0.00% 0
200 199.88 0.03% 200 250 249.85 0.03% 250400 399.67 0.08% 400 500 499.55 0.09% 500
OR ggg ' " TEMSIZE 2 X 0.625 BETA RATIo 0.3125 ANALOG 3 RANGE 0-150
CON T ON Hydrates on plate Do not drive RTD if flowing temp. is + or- 0.5 degrees of test thermometerE E YES coÌDIRINOGN GOOD AS FOUND AS LEFT
ELEED YES BEVERL WN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
#DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!
SERIAL# 13180234 ,MeETEERD 2.067 igggg $¾ REAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKs 30.4 30.5 Same SameCleaned and inspected the orifice plate it was hydrated and ced over creat ng a smaller o ifice size and b ghdifferential. Calibrated the differential and static pressures and verified temperature.
TECHNICIANSIGNATURE
COMPANY BLM CMENTHAOCD' Phone message REVIEWED BY
CONTACT Jeff BrOWO DATE 11/30/2015 DATE 12/7/2015WITNESS SIGNATURE NITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENTCAURTION RRORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 12/2Ì201$
c'u^S'TONIEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 TEDAES UTU87659 API 430-195-002-90000
GPS LOCATION LAT1TUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
ANALOG 0 RANGE 0-400 is"sNUD R-0.01
ma Amos 0.06 ANALOG RANGE 0-1500 s^s 14.73 ^"s" 12.36
LIVEDIFFERENTIIALFOUND 236.60 LIVEDIFFERENTilAL LEFT 169.40 LIVESTATIC PRESS FOUND 34.10 LIVESTATIC PRESS LEFT 30.60AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.06 -0.02% 0 0 0.00 0.00% 0
200 199.88 0.03% 200 250 249.85 0.03% 250400 399.67 0.08% 400 500 499.55 0.09% 500
OR ggg ' " TEMSIZE 2 X 0.625 BETA RATIo 0.3125 ANALOG 3 RANGE 0-150
CON T ON Hydrates on plate Do not drive RTD if flowing temp. is + or- 0.5 degrees of test thermometerE E YES coÌDIRINOGN GOOD AS FOUND AS LEFT
ELEED YES BEVERL WN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
#DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!
SERIAL# 13180234 ,MeETEERD 2.067 igggg $¾ REAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKs 30.4 30.5 Same SameCleaned and inspected the orifice plate it was hydrated and ced over creat ng a smaller o ifice size and b ghdifferential. Calibrated the differential and static pressures and verified temperature.
TECHNICIANSIGNATURE
COMPANY BLM CMENTHAOCD' Phone message REVIEWED BY
CONTACT Jeff BrOWO DATE 11/30/2015 DATE 12/7/2015WITNESS SIGNATURE NITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENTCAURTION RRORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 12/2Ì201$
c'u^S'TONIEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 TEDAES UTU87659 API 430-195-002-90000
GPS LOCATION LAT1TUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
ANALOG 0 RANGE 0-400 is"sNUD R-0.01
ma Amos 0.06 ANALOG RANGE 0-1500 s^s 14.73 ^"s" 12.36
LIVEDIFFERENTIIALFOUND 236.60 LIVEDIFFERENTilAL LEFT 169.40 LIVESTATIC PRESS FOUND 34.10 LIVESTATIC PRESS LEFT 30.60AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.06 -0.02% 0 0 0.00 0.00% 0
200 199.88 0.03% 200 250 249.85 0.03% 250400 399.67 0.08% 400 500 499.55 0.09% 500
OR ggg ' " TEMSIZE 2 X 0.625 BETA RATIo 0.3125 ANALOG 3 RANGE 0-150
CON T ON Hydrates on plate Do not drive RTD if flowing temp. is + or- 0.5 degrees of test thermometerE E YES coÌDIRINOGN GOOD AS FOUND AS LEFT
ELEED YES BEVERL WN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
#DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!
SERIAL# 13180234 ,MeETEERD 2.067 igggg $¾ REAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKs 30.4 30.5 Same SameCleaned and inspected the orifice plate it was hydrated and ced over creat ng a smaller o ifice size and b ghdifferential. Calibrated the differential and static pressures and verified temperature.
TECHNICIANSIGNATURE
COMPANY BLM CMENTHAOCD' Phone message REVIEWED BY
CONTACT Jeff BrOWO DATE 11/30/2015 DATE 12/7/2015WITNESS SIGNATURE NITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENTCAURTION RRORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 12/2Ì201$
c'u^S'TONIEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 TEDAES UTU87659 API 430-195-002-90000
GPS LOCATION LAT1TUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
ANALOG 0 RANGE 0-400 is"sNUD R-0.01
ma Amos 0.06 ANALOG RANGE 0-1500 s^s 14.73 ^"s" 12.36
LIVEDIFFERENTIIALFOUND 236.60 LIVEDIFFERENTilAL LEFT 169.40 LIVESTATIC PRESS FOUND 34.10 LIVESTATIC PRESS LEFT 30.60AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.06 -0.02% 0 0 0.00 0.00% 0
200 199.88 0.03% 200 250 249.85 0.03% 250400 399.67 0.08% 400 500 499.55 0.09% 500
OR ggg ' " TEMSIZE 2 X 0.625 BETA RATIo 0.3125 ANALOG 3 RANGE 0-150
CON T ON Hydrates on plate Do not drive RTD if flowing temp. is + or- 0.5 degrees of test thermometerE E YES coÌDIRINOGN GOOD AS FOUND AS LEFT
ELEED YES BEVERL WN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
#DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!
SERIAL# 13180234 ,MeETEERD 2.067 igggg $¾ REAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKs 30.4 30.5 Same SameCleaned and inspected the orifice plate it was hydrated and ced over creat ng a smaller o ifice size and b ghdifferential. Calibrated the differential and static pressures and verified temperature.
TECHNICIANSIGNATURE
COMPANY BLM CMENTHAOCD' Phone message REVIEWED BY
CONTACT Jeff BrOWO DATE 11/30/2015 DATE 12/7/2015WITNESS SIGNATURE NITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENTCAURTION RRORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 12/2Ì201$
c'u^S'TONIEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 TEDAES UTU87659 API 430-195-002-90000
GPS LOCATION LAT1TUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
ANALOG 0 RANGE 0-400 is"sNUD R-0.01
ma Amos 0.06 ANALOG RANGE 0-1500 s^s 14.73 ^"s" 12.36
LIVEDIFFERENTIIALFOUND 236.60 LIVEDIFFERENTilAL LEFT 169.40 LIVESTATIC PRESS FOUND 34.10 LIVESTATIC PRESS LEFT 30.60AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.06 -0.02% 0 0 0.00 0.00% 0
200 199.88 0.03% 200 250 249.85 0.03% 250400 399.67 0.08% 400 500 499.55 0.09% 500
OR ggg ' " TEMSIZE 2 X 0.625 BETA RATIo 0.3125 ANALOG 3 RANGE 0-150
CON T ON Hydrates on plate Do not drive RTD if flowing temp. is + or- 0.5 degrees of test thermometerE E YES coÌDIRINOGN GOOD AS FOUND AS LEFT
ELEED YES BEVERL WN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
#DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!
SERIAL# 13180234 ,MeETEERD 2.067 igggg $¾ REAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKs 30.4 30.5 Same SameCleaned and inspected the orifice plate it was hydrated and ced over creat ng a smaller o ifice size and b ghdifferential. Calibrated the differential and static pressures and verified temperature.
TECHNICIANSIGNATURE
COMPANY BLM CMENTHAOCD' Phone message REVIEWED BY
CONTACT Jeff BrOWO DATE 11/30/2015 DATE 12/7/2015WITNESS SIGNATURE NITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENTCAURTION RRORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 12/2Ì201$
c'u^S'TONIEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 TEDAES UTU87659 API 430-195-002-90000
GPS LOCATION LAT1TUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
ANALOG 0 RANGE 0-400 is"sNUD R-0.01
ma Amos 0.06 ANALOG RANGE 0-1500 s^s 14.73 ^"s" 12.36
LIVEDIFFERENTIIALFOUND 236.60 LIVEDIFFERENTilAL LEFT 169.40 LIVESTATIC PRESS FOUND 34.10 LIVESTATIC PRESS LEFT 30.60AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.06 -0.02% 0 0 0.00 0.00% 0
200 199.88 0.03% 200 250 249.85 0.03% 250400 399.67 0.08% 400 500 499.55 0.09% 500
OR ggg ' " TEMSIZE 2 X 0.625 BETA RATIo 0.3125 ANALOG 3 RANGE 0-150
CON T ON Hydrates on plate Do not drive RTD if flowing temp. is + or- 0.5 degrees of test thermometerE E YES coÌDIRINOGN GOOD AS FOUND AS LEFT
ELEED YES BEVERL WN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
#DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!
SERIAL# 13180234 ,MeETEERD 2.067 igggg $¾ REAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKs 30.4 30.5 Same SameCleaned and inspected the orifice plate it was hydrated and ced over creat ng a smaller o ifice size and b ghdifferential. Calibrated the differential and static pressures and verified temperature.
TECHNICIANSIGNATURE
COMPANY BLM CMENTHAOCD' Phone message REVIEWED BY
CONTACT Jeff BrOWO DATE 11/30/2015 DATE 12/7/2015WITNESS SIGNATURE NITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENTCAURTION RRORTLOCATIONNO 100 COUNTY GRAND STATE UTAH DATE 12/2Ì201$
c'u^S'TONIEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 TEDAES UTU87659 API 430-195-002-90000
GPS LOCATION LAT1TUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955
OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coiPU ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
ANALOG 0 RANGE 0-400 is"sNUD R-0.01
ma Amos 0.06 ANALOG RANGE 0-1500 s^s 14.73 ^"s" 12.36
LIVEDIFFERENTIIALFOUND 236.60 LIVEDIFFERENTilAL LEFT 169.40 LIVESTATIC PRESS FOUND 34.10 LIVESTATIC PRESS LEFT 30.60AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.06 -0.02% 0 0 0.00 0.00% 0
200 199.88 0.03% 200 250 249.85 0.03% 250400 399.67 0.08% 400 500 499.55 0.09% 500
OR ggg ' " TEMSIZE 2 X 0.625 BETA RATIo 0.3125 ANALOG 3 RANGE 0-150
CON T ON Hydrates on plate Do not drive RTD if flowing temp. is + or- 0.5 degrees of test thermometerE E YES coÌDIRINOGN GOOD AS FOUND AS LEFT
ELEED YES BEVERL WN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
EDOR 0.625 MICSIZE NA #DIVIO!
#DIVIO!SIZE 2.067 TYPE DANIEL STATICTAP US #DIVl0!
SERIAL# 13180234 ,MeETEERD 2.067 igggg $¾ REAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKs 30.4 30.5 Same SameCleaned and inspected the orifice plate it was hydrated and ced over creat ng a smaller o ifice size and b ghdifferential. Calibrated the differential and static pressures and verified temperature.
TECHNICIANSIGNATURE
COMPANY BLM CMENTHAOCD' Phone message REVIEWED BY
CONTACT Jeff BrOWO DATE 11/30/2015 DATE 12/7/2015WITNESS SIGNATURE NITNESS
FORM 9 STATE OF UTAH DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASE DESIGNATION AND SERiAl NUMBER:
SUNDRY NOTICES AND REPORTS ON WELLS
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILL form for such proposals.
1. TYPE OF WELL OIL WELL D GASWELL D OTHER helium
2. NAME OF OPERATOR:
Flatirons Resources LLC
STATE CO ZIP 80020 I PHONE NUMBER:
(720) 636-9624 3. ADDRESS OF OPERATOR:
11080 Circle Point Rd #180 CITY Westminster
4. LOCATION OF WELL
FOOTAGES AT SURFACE: 1402 FNL 757 FEL Sec 4, T19S, R25E
OTRIOTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19¢5 25E
UTU 87659 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
7. UNIT or CA AGREEMENT NAME:
8. WELL NAME and NUMBER:
Flatirons Federal #1-4 9. API NUMBER:
4301950029 10. FIELD AND POOL, OR WILDCAT:
Greater Cisco
COUNTY: Grand County
STATE:
UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
D D ACIDIZE D DEEPEN D REPERFORATE CURRENT FORMATION NOTICE OF INTENT
(Submit in Duplicate) D ALTER CASING D FRACTURE TREAT D SIDETRACK TO REPAIR WELL
Approximate date work will start: D CASING REPAIR D NEW CONSTRUCTION D TEMPORARILY ABANDON
D CHANGE TO PREVIOUS PLANS D OPERATOR CHANGE D TUBING REPAIR
D CHANGE TUBING D PLUG AND ABANDON D VENT OR FlARE
. III SUBSEQUENT REPORT D CHANGE WELL NAME D PLUG BACK D WATER DISPOSAl (Submit Original Form Only)
D CHANGE WELL STATUS D PRODUCTION (START/RESUME) D WATER SHUT -OFF Date of work completion:
D COMMINGLE PRODUCING FORMATIONS D REClAMATION OF WELL SITE ~ OTHER: Calibration 6/13/2016 D D CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected orifice plate. Calibrated the differential and static pressures and verified temperature.
NAME (PLEASE PRINT) Jeffery E. Jones TITLE Managing Director
SIGNATURE --,.....:-...=7b~ ....... 7--""---ir-....::....--~--------- DATE 6/14/2016
(5/2000) (See Instructions on Reverse Side)
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAMESUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below currentbottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL O GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Rd #180CITY
Westminster sTATE CO zi,80020 (720) 636-9624 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402 FNL 757 FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19 25E STATE:UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACKTO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration6/13/2016 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected orifice plate. Calibrated the differential and static pressures and verified temperature.
NAME(PLEASEPRINT) Jeffery E. Jones TITLE Managing Director
SIGNATURE DATE 6/14/2016
(This space for Sta use ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAMESUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below currentbottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL O GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Rd #180CITY
Westminster sTATE CO zi,80020 (720) 636-9624 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402 FNL 757 FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19 25E STATE:UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACKTO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration6/13/2016 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected orifice plate. Calibrated the differential and static pressures and verified temperature.
NAME(PLEASEPRINT) Jeffery E. Jones TITLE Managing Director
SIGNATURE DATE 6/14/2016
(This space for Sta use ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAMESUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below currentbottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL O GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Rd #180CITY
Westminster sTATE CO zi,80020 (720) 636-9624 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402 FNL 757 FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19 25E STATE:UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACKTO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration6/13/2016 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected orifice plate. Calibrated the differential and static pressures and verified temperature.
NAME(PLEASEPRINT) Jeffery E. Jones TITLE Managing Director
SIGNATURE DATE 6/14/2016
(This space for Sta use ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAMESUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below currentbottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL O GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Rd #180CITY
Westminster sTATE CO zi,80020 (720) 636-9624 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402 FNL 757 FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19 25E STATE:UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACKTO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration6/13/2016 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected orifice plate. Calibrated the differential and static pressures and verified temperature.
NAME(PLEASEPRINT) Jeffery E. Jones TITLE Managing Director
SIGNATURE DATE 6/14/2016
(This space for Sta use ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAMESUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below currentbottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL O GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Rd #180CITY
Westminster sTATE CO zi,80020 (720) 636-9624 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402 FNL 757 FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19 25E STATE:UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACKTO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration6/13/2016 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected orifice plate. Calibrated the differential and static pressures and verified temperature.
NAME(PLEASEPRINT) Jeffery E. Jones TITLE Managing Director
SIGNATURE DATE 6/14/2016
(This space for Sta use ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAMESUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below currentbottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL O GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Rd #180CITY
Westminster sTATE CO zi,80020 (720) 636-9624 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402 FNL 757 FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19 25E STATE:UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACKTO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration6/13/2016 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected orifice plate. Calibrated the differential and static pressures and verified temperature.
NAME(PLEASEPRINT) Jeffery E. Jones TITLE Managing Director
SIGNATURE DATE 6/14/2016
(This space for Sta use ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAMESUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below currentbottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL O GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Rd #180CITY
Westminster sTATE CO zi,80020 (720) 636-9624 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402 FNL 757 FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19 25E STATE:UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACKTO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration6/13/2016 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected orifice plate. Calibrated the differential and static pressures and verified temperature.
NAME(PLEASEPRINT) Jeffery E. Jones TITLE Managing Director
SIGNATURE DATE 6/14/2016
(This space for Sta use ly)
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURALRESOURCES
DIVISIONOF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEEOR TRIBE NAMESUNDRY NOTICES AND REPORTS ON WELLS7. UNITor CA AGREEMENT NAME:
Do not use thisform for proposals to drill new wells, significantlydeepen existing wells below currentbottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAMEand NUMBER:OIL WELL O GAS WELL O OTHER helium
Flatirons Federal #1-42. NAMEOF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Rd #180CITY
Westminster sTATE CO zi,80020 (720) 636-9624 Greater Cisco4. LOCATIONOF WELL
FOOTAGESATSURFACE: 1402 FNL 757 FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19 25E STATE:UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACKTO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILYABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG ANDABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELLSTATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate ofwork completion:
O COMMINGLEPRODUCING FORMATIONS RECLAMATIONOF WELL SITE OTHER: Calibration6/13/2016 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Cleaned and inspected orifice plate. Calibrated the differential and static pressures and verified temperature.
NAME(PLEASEPRINT) Jeffery E. Jones TITLE Managing Director
SIGNATURE DATE 6/14/2016
(This space for Sta use ly)
(5/2000) (See Instructions on Reverse
nr Services
Production Management ' Measurement, Analytical, Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORT
LOCATION NO. 100 COUNTY GRAND STATE UTAH DATE 6/13/2016 STATION OR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP I 21 FEDERAL
I UTU87659 API 430-195-002-90000 CUSTOMER LEASE #
GPS LOCATION LATITUDE N 3911. 221'.0" LOGITUDE W 1098.858" I ELEVATION 4955 LEAK OK TEST I PASSED X I NOT PASSED I REPAIRED I NOT REPAIRED TIME OF TEST 1:30 PM TRANSDUCER WEATHERFORD CIM MVT FLOW 0 SERIAL # S7138083JNC TYPE COMPUTER
CALIBRATION EQUIP MODEL#. IF CRYSTAL MODEL IS3316/3000psi, SERIAL TEMP
THERMOPROBE MODEL TL-1W, SERIAL RTD
ALETK SERIES 11, SERIAL 161092 SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 1-5802. DUE 6-18-16 DUE 6-17-16
DIFFERENTIAU'-lE§'- ;iL, " . STATIC TE:$T:~ .... ".:' '.
ANALOG 0 RANGE 0-400 ZERO UNDER -0.01
ZERO AT ATMOS -0.04 ANALOG 1 RANGE 0-1500 BASE 14.73 ATMOS 12.36 PRESSURE PRESSURE PRESS PRESS
LIVE DIFFERENTIIAL FOUND 105.40 LIVE DIFFERENTIIAL LEFT 0.06 LIVE STATIC PRESS FOUND 19.80 LIVE STATIC PRESS LEFT 83.20
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.04 0.01% 0.01 0 -0.04 0.01% 0
200 200.12 -0.03% 200 250 250.64 -0.13% 250
400 400.93 -0.23% 400.02 500 500.48 -0.10% 500.03
ORIFICE PLATE ..... " ....
~..TeMPERA TURE TEST .:" .................. "
SIZE 2 X 0.625 BETA RATIO 0.3125 ANALOG 3 RANGE 0-150 PLATE White greasy substance on plate Do not drive RTD if flowing temp. is + or- 0.5 degrees of test thermometer
CONDITION
EDGES YES SEAL RING GOOD AS FOUND AS LEFT SHARP? CONDITION BEVELED YES BEVEL DOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER PLATE? STREAM?
STAMPED OR 0.625 MEASURED SIZE MIC SIZE NA #DIV/O!
ORIFICE FITTING #DIV/O!
SIZE 2.067 I TYPE DANIEL (Flanged Taps) STATIC TAP US #DIV/O!
SERIAL # 13180234 METER 2.067 LINE TEMPERATURe ....
TUBE ID ........ AS FOUND AS FOUND AS LEFT AS LEFT
THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 77.8 77.9 Same Same
IP address 166.142.167.183. Cleaned and inspected the orifice plate it was coated in a white greasy substance not hydrates creating a smaller orifice size and high differential. Calibrated the differential and static pressures and verified temperature. Compressor went down durring calibration incressed pressure and lowered flow differential.
TECHNICIAN SIGNATURE $_li.iJ~ ...... . .... • ii ><"'WITNESS NOTIFICATION .......... ··.·: .. ··.·."S\,?·.~·1~~f~.· .. I;.'X ." REVIEW
COMPANY BLM CONTACT Phone message REVIEWED BY ~iJl-latJ METHOD
CONTACT Jeff Brown DATE 6/13/2016 DATE 6/14/2016
WITNESS SIGNATURE NITNESS DATE
Production Management ,
Measurement, Analytical,Automation, Well Testing
Ser vic es Omce: 970-245-2490 Fax: 970-245-2492 P.O.BOX3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/13/2016"c'uASTOONMEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955LE, OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:30 PMTRANSDUCER WEATHERFORD CIM MVT coFMLOU
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
DIFFERENTIAL TEST STATIC TESTANALOG 0 RANGE 0-400 TESUEER
-0.01
""R SS RS
-0.04 ANALOG RANGE 0-1500 RA
S 14.73 TRMOS 12.36
LIVEDIFFERENTIIALFOUND 105.40 LIVEDIFFERENTIIALLEFT 0.06 LIVESTATIC PRESS FOUND 19.80 LIVESTATIC PRESS LEFT 83.20
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.04 0.01% 0.01 0 -0.04 0.01% 0200 200.12 -0.03% 200 250 250.64 -0.13% 250
400 400.93 -0.23% 400.02 500 500.48 -0.10% 500.03
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 , RANGE 0-150
CONTEON White greasy substance on plate Do not drive RTD ifflowinq temp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coiDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
ssOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVIO!SERIAL# 13180234 ,MUETEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 77.8 77.9 Same SameIP address 166.142.167.183. Cleaned and inspected the or fice plate it was coated in a white greasy substance nothydrates creating a smaller orifice size and high differential. Calibrated the differential and static pressures and verifiedtemperature. Compressor went down durring calibration incressed pressure and lowered flow differential.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION RFVIEWCONTACT Phone message REVIEWED BYCOMPANY BLM METHOD
CONTACT Jeff BrOWO DATE 6/13/2016 DATE 6/14/2016WITNESS SIGNATURE ITNESS
Production Management ,
Measurement, Analytical,Automation, Well Testing
Ser vic es Omce: 970-245-2490 Fax: 970-245-2492 P.O.BOX3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/13/2016"c'uASTOONMEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955LE, OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:30 PMTRANSDUCER WEATHERFORD CIM MVT coFMLOU
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
DIFFERENTIAL TEST STATIC TESTANALOG 0 RANGE 0-400 TESUEER
-0.01
""R SS RS
-0.04 ANALOG RANGE 0-1500 RA
S 14.73 TRMOS 12.36
LIVEDIFFERENTIIALFOUND 105.40 LIVEDIFFERENTIIALLEFT 0.06 LIVESTATIC PRESS FOUND 19.80 LIVESTATIC PRESS LEFT 83.20
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.04 0.01% 0.01 0 -0.04 0.01% 0200 200.12 -0.03% 200 250 250.64 -0.13% 250
400 400.93 -0.23% 400.02 500 500.48 -0.10% 500.03
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 , RANGE 0-150
CONTEON White greasy substance on plate Do not drive RTD ifflowinq temp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coiDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
ssOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVIO!SERIAL# 13180234 ,MUETEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 77.8 77.9 Same SameIP address 166.142.167.183. Cleaned and inspected the or fice plate it was coated in a white greasy substance nothydrates creating a smaller orifice size and high differential. Calibrated the differential and static pressures and verifiedtemperature. Compressor went down durring calibration incressed pressure and lowered flow differential.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION RFVIEWCONTACT Phone message REVIEWED BYCOMPANY BLM METHOD
CONTACT Jeff BrOWO DATE 6/13/2016 DATE 6/14/2016WITNESS SIGNATURE ITNESS
Production Management ,
Measurement, Analytical,Automation, Well Testing
Ser vic es Omce: 970-245-2490 Fax: 970-245-2492 P.O.BOX3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/13/2016"c'uASTOONMEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955LE, OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:30 PMTRANSDUCER WEATHERFORD CIM MVT coFMLOU
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
DIFFERENTIAL TEST STATIC TESTANALOG 0 RANGE 0-400 TESUEER
-0.01
""R SS RS
-0.04 ANALOG RANGE 0-1500 RA
S 14.73 TRMOS 12.36
LIVEDIFFERENTIIALFOUND 105.40 LIVEDIFFERENTIIALLEFT 0.06 LIVESTATIC PRESS FOUND 19.80 LIVESTATIC PRESS LEFT 83.20
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.04 0.01% 0.01 0 -0.04 0.01% 0200 200.12 -0.03% 200 250 250.64 -0.13% 250
400 400.93 -0.23% 400.02 500 500.48 -0.10% 500.03
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 , RANGE 0-150
CONTEON White greasy substance on plate Do not drive RTD ifflowinq temp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coiDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
ssOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVIO!SERIAL# 13180234 ,MUETEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 77.8 77.9 Same SameIP address 166.142.167.183. Cleaned and inspected the or fice plate it was coated in a white greasy substance nothydrates creating a smaller orifice size and high differential. Calibrated the differential and static pressures and verifiedtemperature. Compressor went down durring calibration incressed pressure and lowered flow differential.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION RFVIEWCONTACT Phone message REVIEWED BYCOMPANY BLM METHOD
CONTACT Jeff BrOWO DATE 6/13/2016 DATE 6/14/2016WITNESS SIGNATURE ITNESS
Production Management ,
Measurement, Analytical,Automation, Well Testing
Ser vic es Omce: 970-245-2490 Fax: 970-245-2492 P.O.BOX3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/13/2016"c'uASTOONMEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955LE, OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:30 PMTRANSDUCER WEATHERFORD CIM MVT coFMLOU
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
DIFFERENTIAL TEST STATIC TESTANALOG 0 RANGE 0-400 TESUEER
-0.01
""R SS RS
-0.04 ANALOG RANGE 0-1500 RA
S 14.73 TRMOS 12.36
LIVEDIFFERENTIIALFOUND 105.40 LIVEDIFFERENTIIALLEFT 0.06 LIVESTATIC PRESS FOUND 19.80 LIVESTATIC PRESS LEFT 83.20
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.04 0.01% 0.01 0 -0.04 0.01% 0200 200.12 -0.03% 200 250 250.64 -0.13% 250
400 400.93 -0.23% 400.02 500 500.48 -0.10% 500.03
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 , RANGE 0-150
CONTEON White greasy substance on plate Do not drive RTD ifflowinq temp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coiDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
ssOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVIO!SERIAL# 13180234 ,MUETEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 77.8 77.9 Same SameIP address 166.142.167.183. Cleaned and inspected the or fice plate it was coated in a white greasy substance nothydrates creating a smaller orifice size and high differential. Calibrated the differential and static pressures and verifiedtemperature. Compressor went down durring calibration incressed pressure and lowered flow differential.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION RFVIEWCONTACT Phone message REVIEWED BYCOMPANY BLM METHOD
CONTACT Jeff BrOWO DATE 6/13/2016 DATE 6/14/2016WITNESS SIGNATURE ITNESS
Production Management ,
Measurement, Analytical,Automation, Well Testing
Ser vic es Omce: 970-245-2490 Fax: 970-245-2492 P.O.BOX3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/13/2016"c'uASTOONMEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955LE, OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:30 PMTRANSDUCER WEATHERFORD CIM MVT coFMLOU
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
DIFFERENTIAL TEST STATIC TESTANALOG 0 RANGE 0-400 TESUEER
-0.01
""R SS RS
-0.04 ANALOG RANGE 0-1500 RA
S 14.73 TRMOS 12.36
LIVEDIFFERENTIIALFOUND 105.40 LIVEDIFFERENTIIALLEFT 0.06 LIVESTATIC PRESS FOUND 19.80 LIVESTATIC PRESS LEFT 83.20
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.04 0.01% 0.01 0 -0.04 0.01% 0200 200.12 -0.03% 200 250 250.64 -0.13% 250
400 400.93 -0.23% 400.02 500 500.48 -0.10% 500.03
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 , RANGE 0-150
CONTEON White greasy substance on plate Do not drive RTD ifflowinq temp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coiDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
ssOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVIO!SERIAL# 13180234 ,MUETEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 77.8 77.9 Same SameIP address 166.142.167.183. Cleaned and inspected the or fice plate it was coated in a white greasy substance nothydrates creating a smaller orifice size and high differential. Calibrated the differential and static pressures and verifiedtemperature. Compressor went down durring calibration incressed pressure and lowered flow differential.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION RFVIEWCONTACT Phone message REVIEWED BYCOMPANY BLM METHOD
CONTACT Jeff BrOWO DATE 6/13/2016 DATE 6/14/2016WITNESS SIGNATURE ITNESS
Production Management ,
Measurement, Analytical,Automation, Well Testing
Ser vic es Omce: 970-245-2490 Fax: 970-245-2492 P.O.BOX3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/13/2016"c'uASTOONMEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955LE, OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:30 PMTRANSDUCER WEATHERFORD CIM MVT coFMLOU
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
DIFFERENTIAL TEST STATIC TESTANALOG 0 RANGE 0-400 TESUEER
-0.01
""R SS RS
-0.04 ANALOG RANGE 0-1500 RA
S 14.73 TRMOS 12.36
LIVEDIFFERENTIIALFOUND 105.40 LIVEDIFFERENTIIALLEFT 0.06 LIVESTATIC PRESS FOUND 19.80 LIVESTATIC PRESS LEFT 83.20
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.04 0.01% 0.01 0 -0.04 0.01% 0200 200.12 -0.03% 200 250 250.64 -0.13% 250
400 400.93 -0.23% 400.02 500 500.48 -0.10% 500.03
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 , RANGE 0-150
CONTEON White greasy substance on plate Do not drive RTD ifflowinq temp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coiDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
ssOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVIO!SERIAL# 13180234 ,MUETEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 77.8 77.9 Same SameIP address 166.142.167.183. Cleaned and inspected the or fice plate it was coated in a white greasy substance nothydrates creating a smaller orifice size and high differential. Calibrated the differential and static pressures and verifiedtemperature. Compressor went down durring calibration incressed pressure and lowered flow differential.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION RFVIEWCONTACT Phone message REVIEWED BYCOMPANY BLM METHOD
CONTACT Jeff BrOWO DATE 6/13/2016 DATE 6/14/2016WITNESS SIGNATURE ITNESS
Production Management ,
Measurement, Analytical,Automation, Well Testing
Ser vic es Omce: 970-245-2490 Fax: 970-245-2492 P.O.BOX3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/13/2016"c'uASTOONMEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955LE, OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:30 PMTRANSDUCER WEATHERFORD CIM MVT coFMLOU
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
DIFFERENTIAL TEST STATIC TESTANALOG 0 RANGE 0-400 TESUEER
-0.01
""R SS RS
-0.04 ANALOG RANGE 0-1500 RA
S 14.73 TRMOS 12.36
LIVEDIFFERENTIIALFOUND 105.40 LIVEDIFFERENTIIALLEFT 0.06 LIVESTATIC PRESS FOUND 19.80 LIVESTATIC PRESS LEFT 83.20
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.04 0.01% 0.01 0 -0.04 0.01% 0200 200.12 -0.03% 200 250 250.64 -0.13% 250
400 400.93 -0.23% 400.02 500 500.48 -0.10% 500.03
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 , RANGE 0-150
CONTEON White greasy substance on plate Do not drive RTD ifflowinq temp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coiDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
ssOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVIO!SERIAL# 13180234 ,MUETEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 77.8 77.9 Same SameIP address 166.142.167.183. Cleaned and inspected the or fice plate it was coated in a white greasy substance nothydrates creating a smaller orifice size and high differential. Calibrated the differential and static pressures and verifiedtemperature. Compressor went down durring calibration incressed pressure and lowered flow differential.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION RFVIEWCONTACT Phone message REVIEWED BYCOMPANY BLM METHOD
CONTACT Jeff BrOWO DATE 6/13/2016 DATE 6/14/2016WITNESS SIGNATURE ITNESS
Production Management ,
Measurement, Analytical,Automation, Well Testing
Ser vic es Omce: 970-245-2490 Fax: 970-245-2492 P.O.BOX3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATIONREPORTLOCATIONNO. 100 COUNTY GRAND STATE UTAH DATE 6/13/2016"c'uASTOONMEORR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FLEEDESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955LE, OK PASSED X NOT PASSED REPAIRED NOT REPAIRED TIME OF TEST 1:30 PMTRANSDUCER WEATHERFORD CIM MVT coFMLOU
ER 0 SERIAL# S7138083JNCCALIBRATIONEQUIP MODEL#, CRYSTAL MODELIS33 16/3000psi, SERIAL THERMOPROBE MODELTL-1W, SERIAL ALETKSERIES 11, SERIAL 161092
SERIAL# RECALIB DATE PRESS 2564-144532 DUE 6-17-16 TEMP 1-5802, DUE 6-18-16 RTD DUE 6-17-16
DIFFERENTIAL TEST STATIC TESTANALOG 0 RANGE 0-400 TESUEER
-0.01
""R SS RS
-0.04 ANALOG RANGE 0-1500 RA
S 14.73 TRMOS 12.36
LIVEDIFFERENTIIALFOUND 105.40 LIVEDIFFERENTIIALLEFT 0.06 LIVESTATIC PRESS FOUND 19.80 LIVESTATIC PRESS LEFT 83.20
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 -0.04 0.01% 0.01 0 -0.04 0.01% 0200 200.12 -0.03% 200 250 250.64 -0.13% 250
400 400.93 -0.23% 400.02 500 500.48 -0.10% 500.03
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETARATIO 0.3125 ANALOG 3 , RANGE 0-150
CONTEON White greasy substance on plate Do not drive RTD ifflowinq temp. is + or- 0.5 degrees of test thermometer
sEHDAGRES, YES coiDRINOGN GOOD AS FOUND AS LEFTBEVELED BEVELDOWNPLATE? YES STREAM? YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
ssOR 0.625 MICSIZE NA #DIVIO!
ORIFICE FITTING #DIVIO!
SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVIO!SERIAL# 13180234 ,MUETEERD 2.067 LINETEMPERATURE
AS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 77.8 77.9 Same SameIP address 166.142.167.183. Cleaned and inspected the or fice plate it was coated in a white greasy substance nothydrates creating a smaller orifice size and high differential. Calibrated the differential and static pressures and verifiedtemperature. Compressor went down durring calibration incressed pressure and lowered flow differential.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION RFVIEWCONTACT Phone message REVIEWED BYCOMPANY BLM METHOD
CONTACT Jeff BrOWO DATE 6/13/2016 DATE 6/14/2016WITNESS SIGNATURE ITNESS
STATE OF UTAH
DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING
SUNDRY NOTICES AND REPORTS ON WELLS
Do not use this form for proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILL form for such proposals.
1. TYPE OF WELL OIL WELL D GASWELL D OTHER helium
2. NAME OF OPERATOR:
Flatirons Resources LLC
STATE CO ZIP80020 I PHONE NUMBER:
(720) 636-9630
3. ADDRESS OF OPERATOR:
11080 Circle Point Road #181 CITY Westminster
4. LOCATION OF WELL
FOOTAGES AT SURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E
OTRIOTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E
FORM 9
5. LEASE DESIGNATION AND SERIAL NUMBER:
UTU 87659
6. IF INDIAN, ALLOTIEE OR TRIBE NAME:
7. UNIT or CA AGREEMENT NAME:
8. WELL NAME and NUMBER:
Flatirons Federal 1-4
9. API NUMBER:
4301950029
10. FIELD AND POOL, OR WILDCAT:
Greater Cisco
COUNTY: Grand County
STATE: UTAH
11. CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
D D ACIDIZE D DEEPEN D REPERFORATE CURRENT FORMATION NOTICE OF INTENT
(Submit in Duplicate) D ALTER CASING D FRACTURE TREAT D SIDETRACK TO REPAIR WELL
Approximate date work will start: D CASING REPAIR D NEW CONSTRUCTION D TEMPORARILY ABANDON
D CHANGE TO PREVIOUS PLANS D OPERATOR CHANGE D TUBING REPAIR
D CHANGE TUBING D PLUG AND ABANDON D VENT OR FLARE
[l] SUBSEQUENT REPORT D CHANGE WELL.NAME D PLUG BACK D WATER DISPOSAL (Submit Original Form Only)
D D D CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT -OFF Date of work completion:
D COMMINGLE PRODUCING FORMATIONS D RECLAMATION OF WELL SITE III OTHER: Calibration Report 12/15/2016 D D CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Calibrated the differential and static pressure and verified temperature. Cleaned and inspected the orifice plate. Updated meter
card, saved configuration and process report.
NAME (PLEASE PRINT) Jeffery E. Jones TITLE
SIGNATURE ___ -="""'''fl....-''~~~04-_+------------ DATE
(5/2000) (See Instructions on Reverse Side)
Managing Director
1/5/2017
RECEIVED JAN 09 ..1c11
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNIT or CA AGREEMENT NAME:Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL heli 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER um Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 Westminster STATE CO zi,80020 (720) 636-9630 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
99. CHECK APPROPRIATE BOXESTO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUGAND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELLNAME PLUG BACK WATER DISPOSAL(Submit OriginalForm Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Calibration Report12/15/2016 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Calibrated the differential and static pressure and verified temperature. Cleaned and inspected the orifice plate. Updated metercard, saved configurationand process report.
RECEIVEDJAN09 A / /
DIV.0F0ltw vm
NAME (PLEASE PRINT) . S TITLEE
(This space for State us
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNIT or CA AGREEMENT NAME:Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL heli 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER um Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 Westminster STATE CO zi,80020 (720) 636-9630 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
99. CHECK APPROPRIATE BOXESTO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUGAND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELLNAME PLUG BACK WATER DISPOSAL(Submit OriginalForm Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Calibration Report12/15/2016 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Calibrated the differential and static pressure and verified temperature. Cleaned and inspected the orifice plate. Updated metercard, saved configurationand process report.
RECEIVEDJAN09 A / /
DIV.0F0ltw vm
NAME (PLEASE PRINT) . S TITLEE
(This space for State us
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNIT or CA AGREEMENT NAME:Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL heli 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER um Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 Westminster STATE CO zi,80020 (720) 636-9630 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
99. CHECK APPROPRIATE BOXESTO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUGAND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELLNAME PLUG BACK WATER DISPOSAL(Submit OriginalForm Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Calibration Report12/15/2016 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Calibrated the differential and static pressure and verified temperature. Cleaned and inspected the orifice plate. Updated metercard, saved configurationand process report.
RECEIVEDJAN09 A / /
DIV.0F0ltw vm
NAME (PLEASE PRINT) . S TITLEE
(This space for State us
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNIT or CA AGREEMENT NAME:Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL heli 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER um Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 Westminster STATE CO zi,80020 (720) 636-9630 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
99. CHECK APPROPRIATE BOXESTO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUGAND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELLNAME PLUG BACK WATER DISPOSAL(Submit OriginalForm Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Calibration Report12/15/2016 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Calibrated the differential and static pressure and verified temperature. Cleaned and inspected the orifice plate. Updated metercard, saved configurationand process report.
RECEIVEDJAN09 A / /
DIV.0F0ltw vm
NAME (PLEASE PRINT) . S TITLEE
(This space for State us
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNIT or CA AGREEMENT NAME:Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL heli 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER um Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 Westminster STATE CO zi,80020 (720) 636-9630 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
99. CHECK APPROPRIATE BOXESTO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUGAND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELLNAME PLUG BACK WATER DISPOSAL(Submit OriginalForm Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Calibration Report12/15/2016 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Calibrated the differential and static pressure and verified temperature. Cleaned and inspected the orifice plate. Updated metercard, saved configurationand process report.
RECEIVEDJAN09 A / /
DIV.0F0ltw vm
NAME (PLEASE PRINT) . S TITLEE
(This space for State us
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNIT or CA AGREEMENT NAME:Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL heli 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER um Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 Westminster STATE CO zi,80020 (720) 636-9630 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
99. CHECK APPROPRIATE BOXESTO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUGAND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELLNAME PLUG BACK WATER DISPOSAL(Submit OriginalForm Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Calibration Report12/15/2016 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Calibrated the differential and static pressure and verified temperature. Cleaned and inspected the orifice plate. Updated metercard, saved configurationand process report.
RECEIVEDJAN09 A / /
DIV.0F0ltw vm
NAME (PLEASE PRINT) . S TITLEE
(This space for State us
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 87659
SUNDRY NOTICES AND REPORTS ON WELLS6. IFINDIAN,ALLOTTEEORTRIBENAME:
7. UNIT or CA AGREEMENT NAME:Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or to
drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL heli 8. WELL NAME and NUMBER:OIL WELL GAS WELL OTHER um Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELD AND POOL, OR WILDCAT:
11080 Circle Point Road #18 Westminster STATE CO zi,80020 (720) 636-9630 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402' FNL 757' FEL Sec 4, T19S, R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
99. CHECK APPROPRIATE BOXESTO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONNOTICE OF INTENT
(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
CHANGE TUBING PLUGAND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELLNAME PLUG BACK WATER DISPOSAL(Submit OriginalForm Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Calibration Report12/15/2016 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Calibrated the differential and static pressure and verified temperature. Cleaned and inspected the orifice plate. Updated metercard, saved configurationand process report.
RECEIVEDJAN09 A / /
DIV.0F0ltw vm
NAME (PLEASE PRINT) . S TITLEE
(This space for State us
(5/2000) (See Instructions on Reverse
nr Services
Production Management Measurement, Analytical, Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O. BOX 3866 Grand Junction. CO 81501
RECEIVED JAN 09 2017
DIV. OF OIL, GAS & MINING
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORT LOCATION NO. 100 COUNTY GRAND STATE 12/14/2016 STATION OR CUSTOMER Flatirons Federal #1-4 RTU ADDRESS 1 00 RTU GROUP
GPS LOCATION
LEAK TEST OK PASSED
LIVE DIFFERENTIIAL FOUND 176.90
AS FOUND
CRYSTAL FLOW COMPUTER
0 0.07
200 200.04
400 399.41
YES
YES
SIZE
SERIAL #
N 3911. 221'.0" LOGITUOE ELEVATION 4955
X NOT PASSED 11:30 AM
SERIAL # S7138083JNC
LIVE DIFFERENTIIAL LEFT 306.20 LIVE STATIC PRESS FOUND 18.20 LIVE STATIC PRESS LEFT 44.60
AS LEFT AS FOUND AS LEFT
% ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
-0.02% 0 0 -0.07 0.01% 0
-0.01% 200.01 250 249.53 0.09% 250.01
0.15% 400 500 499.82 0.04% 500.02
Do not drive RTD if flowing temp. is + or- 0.5 degrees of test thermometer
GOOD AS FOUND AS LEFT
YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
#DIV/O!
2.067
THERMOMETER THERMOMETER FLOW COMPUTER
42.5 Same Same
pressure a ve temperature. and inspected the orifice plate. pdated meter card, saved configuration and process report. Confirmed communications to Scada Lynks. Meter was
ng 0 differential and no flow. Tied back into the RTU and preformed and MVT reset and recalibrated differential. readings came back in. Confirmed communnications back to Scada Lynks.
REGEWEDTH Production Management
Measurement, Analytical, JAN 0 9 20PAutomation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX3866 Grand Junction, CO 81501 DIV.0FOll.,GAS&MINING
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCAT10NNO. 100 COUNTY GRAND STATE UTAH DATE 12/14/2016
c'u^s'T°oNMEOR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FEEDAES#L UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEA OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:30 AM
TRANS CER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATION EQUIP MODEL#PRESS
CRYSTAL MODEL IS33 36/3000psi, SERIALTEMP
THERMOPROBE MODEL TL-1W, SERIALRTD PIE 211 SERIAL 109653 DUE 4-27-17
sERIAL# RECALIB DATE 2262-637684 DUE 4-27-17 1-5710, DUE 4-27-17
DIFFEREN TIALTEST STATICTESTANALOG 0 RANGE 0-400 ¾a"°,"si"0.06 ZERO ASSAURMOS 0.07 ANALOG 1 RANGE 0-1500 |,^;;s 14.73 " 12.36
LIVE DIFFERENTIIAL FOUND 176.90 LIVEDIFFERENTIIAL LEFT 306.20 LIVESTATIC PRESS FOUND 18.20 LIVE STATIC PRESS LEFT 44.60
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.07 -0.02% 0 0 -0.07 0.01% 0
200 200.04 -0.01% 200.01 250 249.53 0.09% 250.01
400 399.41 0.15% 400 500 499.82 0.04% 500.02
ORIFICEPLATE TEMPERATURE TESTSIZE
, 2 X 0.625 BETA RATIO 0.3125 ANALÇ)G 3 RANGE 0-150
CON IT ON Good dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometersEDAGRES, YES COEANLINGN GOOD AS FOUND AS LEFTBEVELED YES BEVEL DOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTERPLATE? STREAM?
MpD OR 0.625 MIC SIZE NA #D IVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMPERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 42.5 42.5 Same SameCalibrated the differential and static pressure and verified th a temperature.Cleaned and inspected the or íice plate.Updated meter card, saved configurationand process repol. Confirmed communications to Scada Lynks. Meter wasshowing 0 differential and no flow. Tied back into the RTU and preformed and MVT reset and recalibrated differential.The readings came back in. Confirmed communnications back to Scada Lynks.
TECHNICIAN SIGNATURE ÑgWITNESS Nt )TIFICATION REVIEW
COMPANY REVIEWED BY
CONTACT DATE DATE 12/15/2016WITNESS SIGNATURE VITNESS
REGEWEDTH Production Management
Measurement, Analytical, JAN 0 9 20PAutomation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX3866 Grand Junction, CO 81501 DIV.0FOll.,GAS&MINING
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCAT10NNO. 100 COUNTY GRAND STATE UTAH DATE 12/14/2016
c'u^s'T°oNMEOR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FEEDAES#L UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEA OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:30 AM
TRANS CER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATION EQUIP MODEL#PRESS
CRYSTAL MODEL IS33 36/3000psi, SERIALTEMP
THERMOPROBE MODEL TL-1W, SERIALRTD PIE 211 SERIAL 109653 DUE 4-27-17
sERIAL# RECALIB DATE 2262-637684 DUE 4-27-17 1-5710, DUE 4-27-17
DIFFEREN TIALTEST STATICTESTANALOG 0 RANGE 0-400 ¾a"°,"si"0.06 ZERO ASSAURMOS 0.07 ANALOG 1 RANGE 0-1500 |,^;;s 14.73 " 12.36
LIVE DIFFERENTIIAL FOUND 176.90 LIVEDIFFERENTIIAL LEFT 306.20 LIVESTATIC PRESS FOUND 18.20 LIVE STATIC PRESS LEFT 44.60
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.07 -0.02% 0 0 -0.07 0.01% 0
200 200.04 -0.01% 200.01 250 249.53 0.09% 250.01
400 399.41 0.15% 400 500 499.82 0.04% 500.02
ORIFICEPLATE TEMPERATURE TESTSIZE
, 2 X 0.625 BETA RATIO 0.3125 ANALÇ)G 3 RANGE 0-150
CON IT ON Good dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometersEDAGRES, YES COEANLINGN GOOD AS FOUND AS LEFTBEVELED YES BEVEL DOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTERPLATE? STREAM?
MpD OR 0.625 MIC SIZE NA #D IVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMPERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 42.5 42.5 Same SameCalibrated the differential and static pressure and verified th a temperature.Cleaned and inspected the or íice plate.Updated meter card, saved configurationand process repol. Confirmed communications to Scada Lynks. Meter wasshowing 0 differential and no flow. Tied back into the RTU and preformed and MVT reset and recalibrated differential.The readings came back in. Confirmed communnications back to Scada Lynks.
TECHNICIAN SIGNATURE ÑgWITNESS Nt )TIFICATION REVIEW
COMPANY REVIEWED BY
CONTACT DATE DATE 12/15/2016WITNESS SIGNATURE VITNESS
REGEWEDTH Production Management
Measurement, Analytical, JAN 0 9 20PAutomation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX3866 Grand Junction, CO 81501 DIV.0FOll.,GAS&MINING
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCAT10NNO. 100 COUNTY GRAND STATE UTAH DATE 12/14/2016
c'u^s'T°oNMEOR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FEEDAES#L UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEA OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:30 AM
TRANS CER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATION EQUIP MODEL#PRESS
CRYSTAL MODEL IS33 36/3000psi, SERIALTEMP
THERMOPROBE MODEL TL-1W, SERIALRTD PIE 211 SERIAL 109653 DUE 4-27-17
sERIAL# RECALIB DATE 2262-637684 DUE 4-27-17 1-5710, DUE 4-27-17
DIFFEREN TIALTEST STATICTESTANALOG 0 RANGE 0-400 ¾a"°,"si"0.06 ZERO ASSAURMOS 0.07 ANALOG 1 RANGE 0-1500 |,^;;s 14.73 " 12.36
LIVE DIFFERENTIIAL FOUND 176.90 LIVEDIFFERENTIIAL LEFT 306.20 LIVESTATIC PRESS FOUND 18.20 LIVE STATIC PRESS LEFT 44.60
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.07 -0.02% 0 0 -0.07 0.01% 0
200 200.04 -0.01% 200.01 250 249.53 0.09% 250.01
400 399.41 0.15% 400 500 499.82 0.04% 500.02
ORIFICEPLATE TEMPERATURE TESTSIZE
, 2 X 0.625 BETA RATIO 0.3125 ANALÇ)G 3 RANGE 0-150
CON IT ON Good dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometersEDAGRES, YES COEANLINGN GOOD AS FOUND AS LEFTBEVELED YES BEVEL DOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTERPLATE? STREAM?
MpD OR 0.625 MIC SIZE NA #D IVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMPERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 42.5 42.5 Same SameCalibrated the differential and static pressure and verified th a temperature.Cleaned and inspected the or íice plate.Updated meter card, saved configurationand process repol. Confirmed communications to Scada Lynks. Meter wasshowing 0 differential and no flow. Tied back into the RTU and preformed and MVT reset and recalibrated differential.The readings came back in. Confirmed communnications back to Scada Lynks.
TECHNICIAN SIGNATURE ÑgWITNESS Nt )TIFICATION REVIEW
COMPANY REVIEWED BY
CONTACT DATE DATE 12/15/2016WITNESS SIGNATURE VITNESS
REGEWEDTH Production Management
Measurement, Analytical, JAN 0 9 20PAutomation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX3866 Grand Junction, CO 81501 DIV.0FOll.,GAS&MINING
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCAT10NNO. 100 COUNTY GRAND STATE UTAH DATE 12/14/2016
c'u^s'T°oNMEOR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FEEDAES#L UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEA OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:30 AM
TRANS CER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATION EQUIP MODEL#PRESS
CRYSTAL MODEL IS33 36/3000psi, SERIALTEMP
THERMOPROBE MODEL TL-1W, SERIALRTD PIE 211 SERIAL 109653 DUE 4-27-17
sERIAL# RECALIB DATE 2262-637684 DUE 4-27-17 1-5710, DUE 4-27-17
DIFFEREN TIALTEST STATICTESTANALOG 0 RANGE 0-400 ¾a"°,"si"0.06 ZERO ASSAURMOS 0.07 ANALOG 1 RANGE 0-1500 |,^;;s 14.73 " 12.36
LIVE DIFFERENTIIAL FOUND 176.90 LIVEDIFFERENTIIAL LEFT 306.20 LIVESTATIC PRESS FOUND 18.20 LIVE STATIC PRESS LEFT 44.60
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.07 -0.02% 0 0 -0.07 0.01% 0
200 200.04 -0.01% 200.01 250 249.53 0.09% 250.01
400 399.41 0.15% 400 500 499.82 0.04% 500.02
ORIFICEPLATE TEMPERATURE TESTSIZE
, 2 X 0.625 BETA RATIO 0.3125 ANALÇ)G 3 RANGE 0-150
CON IT ON Good dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometersEDAGRES, YES COEANLINGN GOOD AS FOUND AS LEFTBEVELED YES BEVEL DOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTERPLATE? STREAM?
MpD OR 0.625 MIC SIZE NA #D IVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMPERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 42.5 42.5 Same SameCalibrated the differential and static pressure and verified th a temperature.Cleaned and inspected the or íice plate.Updated meter card, saved configurationand process repol. Confirmed communications to Scada Lynks. Meter wasshowing 0 differential and no flow. Tied back into the RTU and preformed and MVT reset and recalibrated differential.The readings came back in. Confirmed communnications back to Scada Lynks.
TECHNICIAN SIGNATURE ÑgWITNESS Nt )TIFICATION REVIEW
COMPANY REVIEWED BY
CONTACT DATE DATE 12/15/2016WITNESS SIGNATURE VITNESS
REGEWEDTH Production Management
Measurement, Analytical, JAN 0 9 20PAutomation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX3866 Grand Junction, CO 81501 DIV.0FOll.,GAS&MINING
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCAT10NNO. 100 COUNTY GRAND STATE UTAH DATE 12/14/2016
c'u^s'T°oNMEOR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FEEDAES#L UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEA OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:30 AM
TRANS CER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATION EQUIP MODEL#PRESS
CRYSTAL MODEL IS33 36/3000psi, SERIALTEMP
THERMOPROBE MODEL TL-1W, SERIALRTD PIE 211 SERIAL 109653 DUE 4-27-17
sERIAL# RECALIB DATE 2262-637684 DUE 4-27-17 1-5710, DUE 4-27-17
DIFFEREN TIALTEST STATICTESTANALOG 0 RANGE 0-400 ¾a"°,"si"0.06 ZERO ASSAURMOS 0.07 ANALOG 1 RANGE 0-1500 |,^;;s 14.73 " 12.36
LIVE DIFFERENTIIAL FOUND 176.90 LIVEDIFFERENTIIAL LEFT 306.20 LIVESTATIC PRESS FOUND 18.20 LIVE STATIC PRESS LEFT 44.60
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.07 -0.02% 0 0 -0.07 0.01% 0
200 200.04 -0.01% 200.01 250 249.53 0.09% 250.01
400 399.41 0.15% 400 500 499.82 0.04% 500.02
ORIFICEPLATE TEMPERATURE TESTSIZE
, 2 X 0.625 BETA RATIO 0.3125 ANALÇ)G 3 RANGE 0-150
CON IT ON Good dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometersEDAGRES, YES COEANLINGN GOOD AS FOUND AS LEFTBEVELED YES BEVEL DOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTERPLATE? STREAM?
MpD OR 0.625 MIC SIZE NA #D IVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMPERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 42.5 42.5 Same SameCalibrated the differential and static pressure and verified th a temperature.Cleaned and inspected the or íice plate.Updated meter card, saved configurationand process repol. Confirmed communications to Scada Lynks. Meter wasshowing 0 differential and no flow. Tied back into the RTU and preformed and MVT reset and recalibrated differential.The readings came back in. Confirmed communnications back to Scada Lynks.
TECHNICIAN SIGNATURE ÑgWITNESS Nt )TIFICATION REVIEW
COMPANY REVIEWED BY
CONTACT DATE DATE 12/15/2016WITNESS SIGNATURE VITNESS
REGEWEDTH Production Management
Measurement, Analytical, JAN 0 9 20PAutomation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX3866 Grand Junction, CO 81501 DIV.0FOll.,GAS&MINING
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCAT10NNO. 100 COUNTY GRAND STATE UTAH DATE 12/14/2016
c'u^s'T°oNMEOR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FEEDAES#L UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEA OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:30 AM
TRANS CER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATION EQUIP MODEL#PRESS
CRYSTAL MODEL IS33 36/3000psi, SERIALTEMP
THERMOPROBE MODEL TL-1W, SERIALRTD PIE 211 SERIAL 109653 DUE 4-27-17
sERIAL# RECALIB DATE 2262-637684 DUE 4-27-17 1-5710, DUE 4-27-17
DIFFEREN TIALTEST STATICTESTANALOG 0 RANGE 0-400 ¾a"°,"si"0.06 ZERO ASSAURMOS 0.07 ANALOG 1 RANGE 0-1500 |,^;;s 14.73 " 12.36
LIVE DIFFERENTIIAL FOUND 176.90 LIVEDIFFERENTIIAL LEFT 306.20 LIVESTATIC PRESS FOUND 18.20 LIVE STATIC PRESS LEFT 44.60
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.07 -0.02% 0 0 -0.07 0.01% 0
200 200.04 -0.01% 200.01 250 249.53 0.09% 250.01
400 399.41 0.15% 400 500 499.82 0.04% 500.02
ORIFICEPLATE TEMPERATURE TESTSIZE
, 2 X 0.625 BETA RATIO 0.3125 ANALÇ)G 3 RANGE 0-150
CON IT ON Good dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometersEDAGRES, YES COEANLINGN GOOD AS FOUND AS LEFTBEVELED YES BEVEL DOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTERPLATE? STREAM?
MpD OR 0.625 MIC SIZE NA #D IVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMPERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 42.5 42.5 Same SameCalibrated the differential and static pressure and verified th a temperature.Cleaned and inspected the or íice plate.Updated meter card, saved configurationand process repol. Confirmed communications to Scada Lynks. Meter wasshowing 0 differential and no flow. Tied back into the RTU and preformed and MVT reset and recalibrated differential.The readings came back in. Confirmed communnications back to Scada Lynks.
TECHNICIAN SIGNATURE ÑgWITNESS Nt )TIFICATION REVIEW
COMPANY REVIEWED BY
CONTACT DATE DATE 12/15/2016WITNESS SIGNATURE VITNESS
REGEWEDTH Production Management
Measurement, Analytical, JAN 0 9 20PAutomation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX3866 Grand Junction, CO 81501 DIV.0FOll.,GAS&MINING
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCAT10NNO. 100 COUNTY GRAND STATE UTAH DATE 12/14/2016
c'u^s'T°oNMEOR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 FEEDAES#L UTU87659 API 430-195-002-90000
GPS LOCATION LATITUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955EEA OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:30 AM
TRANS CER WEATHERFORD CIM MVT coFMLOUER 0 SERIAL# S7138083JNC
CALIBRATION EQUIP MODEL#PRESS
CRYSTAL MODEL IS33 36/3000psi, SERIALTEMP
THERMOPROBE MODEL TL-1W, SERIALRTD PIE 211 SERIAL 109653 DUE 4-27-17
sERIAL# RECALIB DATE 2262-637684 DUE 4-27-17 1-5710, DUE 4-27-17
DIFFEREN TIALTEST STATICTESTANALOG 0 RANGE 0-400 ¾a"°,"si"0.06 ZERO ASSAURMOS 0.07 ANALOG 1 RANGE 0-1500 |,^;;s 14.73 " 12.36
LIVE DIFFERENTIIAL FOUND 176.90 LIVEDIFFERENTIIAL LEFT 306.20 LIVESTATIC PRESS FOUND 18.20 LIVE STATIC PRESS LEFT 44.60
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.07 -0.02% 0 0 -0.07 0.01% 0
200 200.04 -0.01% 200.01 250 249.53 0.09% 250.01
400 399.41 0.15% 400 500 499.82 0.04% 500.02
ORIFICEPLATE TEMPERATURE TESTSIZE
, 2 X 0.625 BETA RATIO 0.3125 ANALÇ)G 3 RANGE 0-150
CON IT ON Good dirty Do not drive RTD ifflowing temp. is + or- 0.5 degrees of test thermometersEDAGRES, YES COEANLINGN GOOD AS FOUND AS LEFTBEVELED YES BEVEL DOWN YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTERPLATE? STREAM?
MpD OR 0.625 MIC SIZE NA #D IVIO!
ORIFICE FITTING #DIVIO!SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVIO!
SERIAL# 13180234 ,MUETEERD 2.067 LINE TEMPERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 42.5 42.5 Same SameCalibrated the differential and static pressure and verified th a temperature.Cleaned and inspected the or íice plate.Updated meter card, saved configurationand process repol. Confirmed communications to Scada Lynks. Meter wasshowing 0 differential and no flow. Tied back into the RTU and preformed and MVT reset and recalibrated differential.The readings came back in. Confirmed communnications back to Scada Lynks.
TECHNICIAN SIGNATURE ÑgWITNESS Nt )TIFICATION REVIEW
COMPANY REVIEWED BY
CONTACT DATE DATE 12/15/2016WITNESS SIGNATURE VITNESS
STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING
FORM 9
SUNDRY NOTICES AND REPORTS ON WELLS
Do not use this form for proposals lo drill new wells, significantly deepen existing wells below curent botlom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILL form for such proposals.
1. TYPEOFWELLotL wELL n GAS wELL E orHER helium
5. LEASE DESIGNATION AND SERIAL NUMBER:
UTU 876596. IF INDIAN, ALLOTTEE ORTRIBE NAME
8. WELL NAME and NUMBER:
Flatirons Federal#1-49. API NUMBER:
4301950029
Greater Cisco
couNrY: Grand COUnty
STATE:
UTAH
2.
Flatirons Resources LLC3. ADDRESSOFOPERATOR:
1 1 080 Circle Point Road #18t Westminster CO 800204. LOCATION OF WELL
FoorAGEs Ar sunrece 1 402'FNL 757' FEL Sec4,T1 9S,R25E
QrFvQrR,sEcrloN,rowNsHlP,RANGE,MER|D|AN: SENE 4 19S 25E
CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
tr NOTICE OF INTENT(Submit in Duplicate)
Approximate date work will start:
A suBsEeuENrREPoRT(Submit Original Fom Only)
Date of work completion:
311712017
l-l er-ren casrr.re
! cnsrNe neearn
n cumoe ro PREVrous PLANs
! cneroeruauo
[-l cxeNeeweLLNAME
! rnncrunernenr
! rewcousrRucroN
! oeeneroncunuoe
f] euuoaruonenrooru
n pr-uo encx
l-l nepenromrE cuRRENr FoRMAnoN
n sroernecxroREPAIRwELL
n reupomnrLYABANDoN
n ruaruo nepern
n velroRrune
I wnrenorseoseu
l-l weren sHur-orr
Z orHen, Calibration Report
n cHar.reeweLLSTATUS n pnooucrroN(srART/RESUME)
n courr,rrruele pRoDUcrNG FoRMATToNS l-l necr-nlamoN oF wELL srrE
l-l couvenr wELL rYPE n necouplerE-DTFFERENTFoRMATToN
12. DESCRIBE PROPOSED OR COMPLETED OPEMTIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Calibrated the differential and static pressure and verified the temperature. Cleaned and inspected the orifice plate. Updatedmeter card. Confirmed communications to Scada Link after calibration.
RECEIt/ED
[,{/.{R Z 4 zov
DIV. OFOI[, GAS& MINING
NAME (PLEASE PRINT) ,rLE Managing Director
(This space for
Jeffery Jones
(See lnstructions on Reverse Side)
oArE 312112017SIGNATURE
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #181 Westminster STATE CO zi,80020 (720) 636-9630 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402'FNL 757' FEL Sec4 T49S,R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
19. CHECK APPROPRIATE BOXESTO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONO NOTICE OF INTENT(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Calibration Report3/17/2017 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Calibrated the differential and static pressure and verified the temperature. Cleaned and inspected the orifice plate. Updatedmeter card. Confirmed communications to Scada Link after calibration.
RECEl\/EDMAR2 4 2017
DIV.0FOIL,GAS&MINING
NAME (PLEASE PRINT) Jeffery AODOS TITLE Managing Director
3/21/2017SIGNATURE . DATE
(This space for )
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #181 Westminster STATE CO zi,80020 (720) 636-9630 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402'FNL 757' FEL Sec4 T49S,R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
19. CHECK APPROPRIATE BOXESTO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONO NOTICE OF INTENT(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Calibration Report3/17/2017 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Calibrated the differential and static pressure and verified the temperature. Cleaned and inspected the orifice plate. Updatedmeter card. Confirmed communications to Scada Link after calibration.
RECEl\/EDMAR2 4 2017
DIV.0FOIL,GAS&MINING
NAME (PLEASE PRINT) Jeffery AODOS TITLE Managing Director
3/21/2017SIGNATURE . DATE
(This space for )
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #181 Westminster STATE CO zi,80020 (720) 636-9630 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402'FNL 757' FEL Sec4 T49S,R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
19. CHECK APPROPRIATE BOXESTO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONO NOTICE OF INTENT(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Calibration Report3/17/2017 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Calibrated the differential and static pressure and verified the temperature. Cleaned and inspected the orifice plate. Updatedmeter card. Confirmed communications to Scada Link after calibration.
RECEl\/EDMAR2 4 2017
DIV.0FOIL,GAS&MINING
NAME (PLEASE PRINT) Jeffery AODOS TITLE Managing Director
3/21/2017SIGNATURE . DATE
(This space for )
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #181 Westminster STATE CO zi,80020 (720) 636-9630 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402'FNL 757' FEL Sec4 T49S,R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
19. CHECK APPROPRIATE BOXESTO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONO NOTICE OF INTENT(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Calibration Report3/17/2017 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Calibrated the differential and static pressure and verified the temperature. Cleaned and inspected the orifice plate. Updatedmeter card. Confirmed communications to Scada Link after calibration.
RECEl\/EDMAR2 4 2017
DIV.0FOIL,GAS&MINING
NAME (PLEASE PRINT) Jeffery AODOS TITLE Managing Director
3/21/2017SIGNATURE . DATE
(This space for )
(5/2000) (See Instructions on Reverse
STATE OF UTAH FORM 9DEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS AND MINING 5. LEASEDESIGNATIONANDSERIALNUMBER:
UTU 876596. IF INDIAN,ALLOTTEE OR TRIBE NAME
SUNDRY NOTICES AND REPORTS ON WELLS7. UNIT or CA AGREEMENT NAME:
Do not use this form for proposals to drill new wells, significantlydeepen existingwells below current bottom-hole depth, reenter plugged wells, or todrill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILLform for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:OIL WELL GAS WELL O OTHER helium
Flatirons Federal #1-42. NAME OF OPERATOR: 9. API NUMBER:
Flatirons Resources LLC 43019500293. ADDRESS OF OPERATOR: PHONE NUMBER: 10. FIELDAND POOL, OR WILDCAT:
11080 Circle Point Road #181 Westminster STATE CO zi,80020 (720) 636-9630 Greater Cisco4. LOCATION OF WELL
FOOTAGESATSURFACE: 1402'FNL 757' FEL Sec4 T49S,R25E COUNTY: Grand County
QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: SENE 4 19S 25E STATE:UTAH
19. CHECK APPROPRIATE BOXESTO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATATYPE OF SUBMISSION TYPE OF ACTION
O ACIDIZE DEEPEN REPERFORATE CURRENT FORMATIONO NOTICE OF INTENT(Submit in Duplicate) ALTER CASING FRACTURE TREAT SIDETRACK TO REPAIR WELL
Approximate date work willstart: CASING REPAIR NEW CONSTRUCTION TEMPORARILY ABANDON
CHANGE TO PREVIOUS PLANS OPERATOR CHANGE TUBING REPAIR
O CHANGE TUBING PLUG AND ABANDON VENT OR FLARE
SUBSEQUENT REPORT CHANGE WELL NAME PLUG BACK WATER DISPOSAL(Submit Original Form Only)
O CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHUT-OFFDate of work completion:
COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER: Calibration Report3/17/2017 O CONVERT WELL TYPE RECOMPLETE - DIFFERENT FORMATION
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Calibrated the differential and static pressure and verified the temperature. Cleaned and inspected the orifice plate. Updatedmeter card. Confirmed communications to Scada Link after calibration.
RECEl\/EDMAR2 4 2017
DIV.0FOIL,GAS&MINING
NAME (PLEASE PRINT) Jeffery AODOS TITLE Managing Director
3/21/2017SIGNATURE . DATE
(This space for )
(5/2000) (See Instructions on Reverse
x&trProduction ManagementMeasurement, Analytical,Automation, Well Testing
Oltice: 97 0-245-2490 Fax: 970-245-2452P.O. BOX 3866 Grand Junction, CO 8'1501
FLATIRON RESOURCES LLC . ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLocArroN No. 1 00 COUNTY GRAND STATE UTAH DAIE 311612017
'"-,i.'+31,3S Flatirons Federal #1-4 Rru ADDRESSIl00 arucnoue I f{ 1??:H I uruezoso Apr 430-1e5-002-e0000
GPS LOCATION LArruDE N 39 11.221'.0" LoGrruDE W 109 8.858" ! ereveroru 4955
i::T OK I eoss.o X I *o'"ess., ! neeoraeo lruornrenrneo
rrMEoFrEsr 11:00 AMTRANSDUCER'-;#".^ WEATHERFORD CIM MVT FLOW
CoMPUTER U SERTAL# 57138083JNCCALTBRATTON EOU|P MOoEL#. looE, (:RYSIAI MoDFI ls3:t 36/:to00psi, SERIAL I TEi,o IHERMOPROtsE MOIJLL lL-lW, SERIAL
sERrALd REcALTBDATE lHKEss 2262-637684ouE4-27-17 I IEMH 1-b71o.DUL4-27-17RTD PIE 21 1 SERTAL 1 09653 DUE 4-27-1 7
ANALOG 0 {ANGE 0-400 ':#.:x?T 0.01 ":ll'.|H"" o.oo ANALOG 1 n,cNGE 0-1 500 BASE
PRESS 14.73 ATMOS
PRESS 12.36
LIVE DIFFERENTIIAL FOUND 203.60 LrvE DTFFERENTTAL LEFr 201 .50 LrvE srArrc PRESS FoUND 30.00 LrvE srAflc PRESS LEFr 30.00
AS FOUND AS LEFT AS FOUND AS LEFT
CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0.03 0 0.04 -0.01% 0
200 200.06 -0.02Yo 200.04 250 250.38 -0.08% 250
400 400.37 -0.09% 400.02 500 500.22 -0.04% 500.01
QRIFICE PLATE TEMPERATURE TESTsrzE 2 .X 0.625 BErAnelo 0.3125 ANALOG 3 RANGE 0-150
".,'^iliil* Good dirty Do not drive RTD if flowinq temp. is + or- 0.5 degrees of test thermometer
.'#fl'r', YES ;5ffiil,:"" cooD AS FOUND AS LEFT
""',li?? YES 'i'r.R'Ji,i^ YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTER
"'js::x"r 0.625 Mrc srzE NA #Drv/o!
ORIFICE FITT!NG #Dtv/0!
stzE 2.067 | rvpe DANIEL (Flansed raps) STATIC TAP US #DIV/O!
SERTAL # 13180234 ffi$ 2.067 L!NE TEMPERATUREAS FOUND AS FOUND AS LEFT AS LEFT
REMARKS
THERI\,,IOMETER FLOW COMPUTER IHERMOMETER FLOW COMPUTER
62.7 62.7 Same Same
Calibrated the differential and static pressure and verified the temperature. Cleaned and inspected the orifice plate.Updated meter card, saved configuration and process report. Confirmed communications to Scada Lynks.
TECHNICIAN SIGNATURE 5or* 6. {lr.r.lilt;il?;-:;:..,.!..::i;;.i:iREV.lEW, j;r',.,,..,il,r
"".'COMPANY
UONIAUIMETHOD
TEVTEWEDBY edfu {f".&kCONTACT DATE DArE 311712017
VITNESS SIGNATURE /ITNESS DATE
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND $TATE UTAH DATE 3/16/2017
"c'us'T°oN RR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATlTUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955‡EEAS OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPUWTER 0 SERIAL# S7138083JNC
CALlBRATION EQUIP MODEL# CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODEL TL-iW, SERIALSERIAL# RECALIB DATE PRESS 2262-637684 DUE 4-27-17 TEMP 1-5710, DUE 4-27-17 RTD PIE 211 SERIAL 109653 DUE 4-27-17
DIFFERENTIAL TEST STATICTESTANALOG 0 RANGE 0-400 SROESSN ER 0.01 ZERO ASSAURMOS 0.00 ANALOG 1 RANGE 0-1500 ,"RAE
S 14.73 ^,2°s6 12.36LIVE DIFFERENTilAL FOUND 203.60 LIVE DJFFERENTilAL LEFT 201.50 LIVESTATlC PRESS FOUND 30.00 LIVESTATIC PRESS LEFT 30.00
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0.03 0 0.04 -0.01% 0
200 200.06 -0.02% 200.04 250 250.38 -0.08% 250
400 400.37 -0.09% 400.02 500 500.22 -0.04% 500.01
ORIFICE PLATE TEMPERATURE TESTSIZE 2 . X 0.625 BETA RATIO 0.3125 ANALOG 3 RANGE 0-150CONLD
T ON Good dirty Do not drive RTD if flowing temp. is + or-0.5 degrees of test thermometersEDAGRES, YES CSEA INOGN GOOD AS FOUND AS LEFT
BEVELED BEVEL DOWNYES YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTERPLATE? STREAM?
QWEDOR 0.625 MICSIZE NA #DIVl0!
ORIFICE FITTING #DIVl0!SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVl0!
SERIAL# 13180234 METEERD 2.067 LINE TEMPERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 62.7 62.7 Same SameCalibrated the differential and static pressure and verified tha temperature. Cleaned and inspected the orifice plate.Updated meter card, saved configuration and process report. Confirmed communications to Scada Lynks.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION REVIEWCOMPANY O REV1EWED BY
CONTACT DATE DATE 3/17/2017WITNESS SIGNATURE ITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND $TATE UTAH DATE 3/16/2017
"c'us'T°oN RR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATlTUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955‡EEAS OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPUWTER 0 SERIAL# S7138083JNC
CALlBRATION EQUIP MODEL# CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODEL TL-iW, SERIALSERIAL# RECALIB DATE PRESS 2262-637684 DUE 4-27-17 TEMP 1-5710, DUE 4-27-17 RTD PIE 211 SERIAL 109653 DUE 4-27-17
DIFFERENTIAL TEST STATICTESTANALOG 0 RANGE 0-400 SROESSN ER 0.01 ZERO ASSAURMOS 0.00 ANALOG 1 RANGE 0-1500 ,"RAE
S 14.73 ^,2°s6 12.36LIVE DIFFERENTilAL FOUND 203.60 LIVE DJFFERENTilAL LEFT 201.50 LIVESTATlC PRESS FOUND 30.00 LIVESTATIC PRESS LEFT 30.00
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0.03 0 0.04 -0.01% 0
200 200.06 -0.02% 200.04 250 250.38 -0.08% 250
400 400.37 -0.09% 400.02 500 500.22 -0.04% 500.01
ORIFICE PLATE TEMPERATURE TESTSIZE 2 . X 0.625 BETA RATIO 0.3125 ANALOG 3 RANGE 0-150CONLD
T ON Good dirty Do not drive RTD if flowing temp. is + or-0.5 degrees of test thermometersEDAGRES, YES CSEA INOGN GOOD AS FOUND AS LEFT
BEVELED BEVEL DOWNYES YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTERPLATE? STREAM?
QWEDOR 0.625 MICSIZE NA #DIVl0!
ORIFICE FITTING #DIVl0!SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVl0!
SERIAL# 13180234 METEERD 2.067 LINE TEMPERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 62.7 62.7 Same SameCalibrated the differential and static pressure and verified tha temperature. Cleaned and inspected the orifice plate.Updated meter card, saved configuration and process report. Confirmed communications to Scada Lynks.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION REVIEWCOMPANY O REV1EWED BY
CONTACT DATE DATE 3/17/2017WITNESS SIGNATURE ITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND $TATE UTAH DATE 3/16/2017
"c'us'T°oN RR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATlTUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955‡EEAS OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPUWTER 0 SERIAL# S7138083JNC
CALlBRATION EQUIP MODEL# CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODEL TL-iW, SERIALSERIAL# RECALIB DATE PRESS 2262-637684 DUE 4-27-17 TEMP 1-5710, DUE 4-27-17 RTD PIE 211 SERIAL 109653 DUE 4-27-17
DIFFERENTIAL TEST STATICTESTANALOG 0 RANGE 0-400 SROESSN ER 0.01 ZERO ASSAURMOS 0.00 ANALOG 1 RANGE 0-1500 ,"RAE
S 14.73 ^,2°s6 12.36LIVE DIFFERENTilAL FOUND 203.60 LIVE DJFFERENTilAL LEFT 201.50 LIVESTATlC PRESS FOUND 30.00 LIVESTATIC PRESS LEFT 30.00
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0.03 0 0.04 -0.01% 0
200 200.06 -0.02% 200.04 250 250.38 -0.08% 250
400 400.37 -0.09% 400.02 500 500.22 -0.04% 500.01
ORIFICE PLATE TEMPERATURE TESTSIZE 2 . X 0.625 BETA RATIO 0.3125 ANALOG 3 RANGE 0-150CONLD
T ON Good dirty Do not drive RTD if flowing temp. is + or-0.5 degrees of test thermometersEDAGRES, YES CSEA INOGN GOOD AS FOUND AS LEFT
BEVELED BEVEL DOWNYES YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTERPLATE? STREAM?
QWEDOR 0.625 MICSIZE NA #DIVl0!
ORIFICE FITTING #DIVl0!SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVl0!
SERIAL# 13180234 METEERD 2.067 LINE TEMPERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 62.7 62.7 Same SameCalibrated the differential and static pressure and verified tha temperature. Cleaned and inspected the orifice plate.Updated meter card, saved configuration and process report. Confirmed communications to Scada Lynks.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION REVIEWCOMPANY O REV1EWED BY
CONTACT DATE DATE 3/17/2017WITNESS SIGNATURE ITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND $TATE UTAH DATE 3/16/2017
"c'us'T°oN RR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATlTUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955‡EEAS OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPUWTER 0 SERIAL# S7138083JNC
CALlBRATION EQUIP MODEL# CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODEL TL-iW, SERIALSERIAL# RECALIB DATE PRESS 2262-637684 DUE 4-27-17 TEMP 1-5710, DUE 4-27-17 RTD PIE 211 SERIAL 109653 DUE 4-27-17
DIFFERENTIAL TEST STATICTESTANALOG 0 RANGE 0-400 SROESSN ER 0.01 ZERO ASSAURMOS 0.00 ANALOG 1 RANGE 0-1500 ,"RAE
S 14.73 ^,2°s6 12.36LIVE DIFFERENTilAL FOUND 203.60 LIVE DJFFERENTilAL LEFT 201.50 LIVESTATlC PRESS FOUND 30.00 LIVESTATIC PRESS LEFT 30.00
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0.03 0 0.04 -0.01% 0
200 200.06 -0.02% 200.04 250 250.38 -0.08% 250
400 400.37 -0.09% 400.02 500 500.22 -0.04% 500.01
ORIFICE PLATE TEMPERATURE TESTSIZE 2 . X 0.625 BETA RATIO 0.3125 ANALOG 3 RANGE 0-150CONLD
T ON Good dirty Do not drive RTD if flowing temp. is + or-0.5 degrees of test thermometersEDAGRES, YES CSEA INOGN GOOD AS FOUND AS LEFT
BEVELED BEVEL DOWNYES YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTERPLATE? STREAM?
QWEDOR 0.625 MICSIZE NA #DIVl0!
ORIFICE FITTING #DIVl0!SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVl0!
SERIAL# 13180234 METEERD 2.067 LINE TEMPERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 62.7 62.7 Same SameCalibrated the differential and static pressure and verified tha temperature. Cleaned and inspected the orifice plate.Updated meter card, saved configuration and process report. Confirmed communications to Scada Lynks.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION REVIEWCOMPANY O REV1EWED BY
CONTACT DATE DATE 3/17/2017WITNESS SIGNATURE ITNESS
Production ManagementMeasurement, Analytical,Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATIONNO. 100 COUNTY GRAND $TATE UTAH DATE 3/16/2017
"c'us'T°oN RR Flatirons Federal #1-4 RTU ADDRESS 100 RTUGROUP 21 FEEDAESRAL UTU87659 API 430-195-002-90000
GPS LOCATION LATlTUDE N 39 11. 221'.0" LOGITUDE W 109 8.858" ELEVATION 4955‡EEAS OK PASSED X NOTPASSED REPAIRED NOTREPAIRED TIMEOFTEST 11:00 AMTRANSDUCER WEATHERFORD CIM MVT coûPUWTER 0 SERIAL# S7138083JNC
CALlBRATION EQUIP MODEL# CRYSTAL MODEL IS33 36/3000psi, SERIAL THERMOPROBE MODEL TL-iW, SERIALSERIAL# RECALIB DATE PRESS 2262-637684 DUE 4-27-17 TEMP 1-5710, DUE 4-27-17 RTD PIE 211 SERIAL 109653 DUE 4-27-17
DIFFERENTIAL TEST STATICTESTANALOG 0 RANGE 0-400 SROESSN ER 0.01 ZERO ASSAURMOS 0.00 ANALOG 1 RANGE 0-1500 ,"RAE
S 14.73 ^,2°s6 12.36LIVE DIFFERENTilAL FOUND 203.60 LIVE DJFFERENTilAL LEFT 201.50 LIVESTATlC PRESS FOUND 30.00 LIVESTATIC PRESS LEFT 30.00
AS FOUND AS LEFT AS FOUND AS LEFTCRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER CRYSTAL FLOW COMPUTER % ERROR FLOW COMPUTER
0 0.00 0.00% 0.03 0 0.04 -0.01% 0
200 200.06 -0.02% 200.04 250 250.38 -0.08% 250
400 400.37 -0.09% 400.02 500 500.22 -0.04% 500.01
ORIFICE PLATE TEMPERATURE TESTSIZE 2 . X 0.625 BETA RATIO 0.3125 ANALOG 3 RANGE 0-150CONLD
T ON Good dirty Do not drive RTD if flowing temp. is + or-0.5 degrees of test thermometersEDAGRES, YES CSEA INOGN GOOD AS FOUND AS LEFT
BEVELED BEVEL DOWNYES YES DEVICE FLOW COMPUTER % ERROR FLOW COMPUTERPLATE? STREAM?
QWEDOR 0.625 MICSIZE NA #DIVl0!
ORIFICE FITTING #DIVl0!SIZE 2.067 TYPE DANIEL (Flanged Taps) STATIC TAP US #DIVl0!
SERIAL# 13180234 METEERD 2.067 LINE TEMPERATUREAS FOUND AS FOUND AS LEFT AS LEFTTHERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS 62.7 62.7 Same SameCalibrated the differential and static pressure and verified tha temperature. Cleaned and inspected the orifice plate.Updated meter card, saved configuration and process report. Confirmed communications to Scada Lynks.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION REVIEWCOMPANY O REV1EWED BY
CONTACT DATE DATE 3/17/2017WITNESS SIGNATURE ITNESS
RECEIVED: Jun. 23, 2017
STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS, AND MINING
FORM 9
5.LEASE DESIGNATION AND SERIAL NUMBER: UTU87659
SUNDRY NOTICES AND REPORTS ON WELLS
Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATIONFOR PERMIT TO DRILL form for such proposals.
6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
7.UNIT or CA AGREEMENT NAME:
1. TYPE OF WELL
8. WELL NAME and NUMBER: Flatirons Federal 1-4
2. NAME OF OPERATOR: FLATIRONS RESOURCES, LLC
9. API NUMBER: 43019500290000
3. ADDRESS OF OPERATOR: PHONE NUMBER: 11080 CIRCLE POINT ROAD, SUITE 180 , WESTMINSTER, CO, 800202771 303-292-3902
9. FIELD and POOL or WILDCAT: GREATER CISCO
4. LOCATION OF WELL FOOTAGES AT SURFACE: 1402 FNL 757 FEL QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: Qtr/Qtr: SENE Section: 4 Township: 19S Range: 25E Meridian: S
COUNTY: GRAND
STATE: UTAH
11.
CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
NOTICE OF INTENTApproximate date work will start:
SUBSEQUENT REPORTDate of Work Completion:
6 /21 /2017
SPUD REPORTDate of Spud:
DRILLING REPORTReport Date:
ACIDIZE ALTER CASING CASING REPAIR
CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME
CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE
DEEPEN FRACTURE TREAT NEW CONSTRUCTION
OPERATOR CHANGE PLUG AND ABANDON PLUG BACK
PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION
REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON
TUBING REPAIR VENT OR FLARE WATER DISPOSAL
WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSION
WILDCAT WELL DETERMINATION OTHER OTHER: calibration report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Use of new on shore order number 5 compliance report. Calibrated thedifferential and verified the static pressure and temperature. Inspected
and cleaned orifice plate
NAME (PLEASE PRINT) PHONE NUMBER Sharon Wells 303 292-3902
TITLE Sr. Engr. Tech
SIGNATURE N/A
DATE 6 /23 /2017
July 20, 2017
Sundry Number: 81135 API Well Number: 43019500290000Sundry Number: 81135 API Well Number: 43019500290000
FORM 9STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTU87659
SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:
FOR PERMIT TO DRILL form for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:FLATIRONSRESOURCES, LLC 43019500290000
3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:11080 CIRCLE POINT ROAD, SUITE 180 , WESTMINSTER, CO, 800202771 303-292-39REATER CISCO
4. LOCATION OF WELL COUNTY:FOOTAGES AT SURFACE: GRAND
1402 FNL 757 FELQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:
QtrlQtr: SENE Section: 4 Township: 19S Range: 25E Meridian: S UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
ACI DIZE ALTER CASING CASING REPAIR
NOTICE OF INTENT CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAMEApproximate date work will start:
CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE
SUBSEQUENT REPORTDate of Work Completion: DEEPEN FRACTURE TREAT NEW CONSTRUCTION
6/21/2017OPERATOR CHANGE PLUG AND ABANDON PLUG BACK
SPUD REPORT PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONDate of Spud:
REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON
TUBING REPAIR VENT OR FLARE WATER DISPOSAL
DRILLING REPORTReport Date: WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSION
WILDCATWELLDETERMINATION OTHER OTHER: calibration report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Use of new on shore order number 5 compliance report. Calibrated the Accepted by thedifferential and verified the static pressure and temperature. Inspected Utah Division of
and cleaned orifice plate Oil, Gas and Mining
FOR RECORD ONLYJuly 20, 2017
NAME (PLEASE PRINT) PHONE NUMBER TITLESharon Wells 303 292-3902 Sr. Engr. Tech
SIGNATURE DATEN/A 6/23/2017
RECEIVED: Jun. 23,
Sundry Number: 81135 API Well Number: 43019500290000
FORM 9STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTU87659
SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:
FOR PERMIT TO DRILL form for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:FLATIRONSRESOURCES, LLC 43019500290000
3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:11080 CIRCLE POINT ROAD, SUITE 180 , WESTMINSTER, CO, 800202771 303-292-39REATER CISCO
4. LOCATION OF WELL COUNTY:FOOTAGES AT SURFACE: GRAND
1402 FNL 757 FELQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:
QtrlQtr: SENE Section: 4 Township: 19S Range: 25E Meridian: S UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
ACI DIZE ALTER CASING CASING REPAIR
NOTICE OF INTENT CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAMEApproximate date work will start:
CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE
SUBSEQUENT REPORTDate of Work Completion: DEEPEN FRACTURE TREAT NEW CONSTRUCTION
6/21/2017OPERATOR CHANGE PLUG AND ABANDON PLUG BACK
SPUD REPORT PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONDate of Spud:
REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON
TUBING REPAIR VENT OR FLARE WATER DISPOSAL
DRILLING REPORTReport Date: WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSION
WILDCATWELLDETERMINATION OTHER OTHER: calibration report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Use of new on shore order number 5 compliance report. Calibrated the Accepted by thedifferential and verified the static pressure and temperature. Inspected Utah Division of
and cleaned orifice plate Oil, Gas and Mining
FOR RECORD ONLYJuly 20, 2017
NAME (PLEASE PRINT) PHONE NUMBER TITLESharon Wells 303 292-3902 Sr. Engr. Tech
SIGNATURE DATEN/A 6/23/2017
RECEIVED: Jun. 23,
Sundry Number: 81135 API Well Number: 43019500290000
FORM 9STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTU87659
SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:
FOR PERMIT TO DRILL form for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:FLATIRONSRESOURCES, LLC 43019500290000
3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:11080 CIRCLE POINT ROAD, SUITE 180 , WESTMINSTER, CO, 800202771 303-292-39REATER CISCO
4. LOCATION OF WELL COUNTY:FOOTAGES AT SURFACE: GRAND
1402 FNL 757 FELQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:
QtrlQtr: SENE Section: 4 Township: 19S Range: 25E Meridian: S UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
ACI DIZE ALTER CASING CASING REPAIR
NOTICE OF INTENT CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAMEApproximate date work will start:
CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE
SUBSEQUENT REPORTDate of Work Completion: DEEPEN FRACTURE TREAT NEW CONSTRUCTION
6/21/2017OPERATOR CHANGE PLUG AND ABANDON PLUG BACK
SPUD REPORT PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONDate of Spud:
REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON
TUBING REPAIR VENT OR FLARE WATER DISPOSAL
DRILLING REPORTReport Date: WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSION
WILDCATWELLDETERMINATION OTHER OTHER: calibration report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Use of new on shore order number 5 compliance report. Calibrated the Accepted by thedifferential and verified the static pressure and temperature. Inspected Utah Division of
and cleaned orifice plate Oil, Gas and Mining
FOR RECORD ONLYJuly 20, 2017
NAME (PLEASE PRINT) PHONE NUMBER TITLESharon Wells 303 292-3902 Sr. Engr. Tech
SIGNATURE DATEN/A 6/23/2017
RECEIVED: Jun. 23,
Sundry Number: 81135 API Well Number: 43019500290000
FORM 9STATE OF UTAH
DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTU87659
SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:
FOR PERMIT TO DRILL form for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:FLATIRONSRESOURCES, LLC 43019500290000
3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:11080 CIRCLE POINT ROAD, SUITE 180 , WESTMINSTER, CO, 800202771 303-292-39REATER CISCO
4. LOCATION OF WELL COUNTY:FOOTAGES AT SURFACE: GRAND
1402 FNL 757 FELQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:
QtrlQtr: SENE Section: 4 Township: 19S Range: 25E Meridian: S UTAH
CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
ACI DIZE ALTER CASING CASING REPAIR
NOTICE OF INTENT CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAMEApproximate date work will start:
CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE
SUBSEQUENT REPORTDate of Work Completion: DEEPEN FRACTURE TREAT NEW CONSTRUCTION
6/21/2017OPERATOR CHANGE PLUG AND ABANDON PLUG BACK
SPUD REPORT PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONDate of Spud:
REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON
TUBING REPAIR VENT OR FLARE WATER DISPOSAL
DRILLING REPORTReport Date: WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSION
WILDCATWELLDETERMINATION OTHER OTHER: calibration report
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.
Use of new on shore order number 5 compliance report. Calibrated the Accepted by thedifferential and verified the static pressure and temperature. Inspected Utah Division of
and cleaned orifice plate Oil, Gas and Mining
FOR RECORD ONLYJuly 20, 2017
NAME (PLEASE PRINT) PHONE NUMBER TITLESharon Wells 303 292-3902 Sr. Engr. Tech
SIGNATURE DATEN/A 6/23/2017
RECEIVED: Jun. 23,
RECEIVED: Jun. 23, 2017
STATE DATE
100 21
MAKE LEAK TEST OK PASS X NO
PASS FIXED NOT FIXED
SERIAL NUMBER 0.025%
TEMP
deg F1.00
MVT FC # 1
ATMOS DEVICE
PRESS DEVICE
TEMP DEVICE
RTD DEVICE
1.50.5
0" H2O 400 0 PSIA 15000" H2O 400 0 PSIG 500
0.10 AS Found
AS LEFT 0.13 AS
FoundAS
LEFT
0.510 1.505
ZERO ATOMOS ZERO
AVG DP
AVG SP
FULL RANGE
FULL RANGE
SIZE X AI # 2 DEVICE RANGE
CALIB RANGE
1.018
ZERO
AVG TEMP
MAKE TYPE FULL RANGE
CRYSTAL MODEL IS336/3000, SER# 2262-637684, CAL DATE 4-27-16
THERMOPROBE TL-1W, SER# 1-9574, CAL DATE 10-24-16
PIE 211 SER# 109653,
CAL DATE 4-27-16
STATION OR CUSTOMER
FLOW COMPUTER
6/21/2017
N 39° 11. 221'0" W 109° 8.858" ELEVATION 4955 TIME OF TESTLAST CAL
DATE 3/16/2017CALCULATION METHOD
AGA 3 1992, AGA 8 DETAIL
Flatirons Federal #1-4 RTU GROUP
LIVE DIFF READING
UTU87659 API 430-195-002-90000
STATIC TEST
K500WEATHERFORD
WEATHERFORD CIM MODEL NUMBER
ACCY 0.025%
IN DEG F
0.19
0.01 AS LEFT
MVT ACCY OF CAL RANGE in INCH H20
ATMOS PRESS
TEMP RANGE 32°-250° F ACCY
0.10%IN
DEG F0.218 OHMS
RANGE 10-2000 OhmsPRESS RANGE
GPS LOCATION
MONARK MODEL 5696-0321-Cal SER# 40000252, CAL DATE 1-19-17
BASE CALC INFORMATION
REMARKS
TECHNICIAN SIGNATURE
180
-0.550 400.04
4.4 TO 17.4 PSI
ACCY0.02%
ACCY IN PSI
0.003 PRESS RANGE
0-3000 PSI 0-996.5" H20
176.60
AS FOUND ALLOWABLE THRESHOLD
ACCY 0.05%
IN PSI IN H20
0
TEST DEVICE FLOW COMPUTER
SPECIFIC GRAVITY
ZER0 UNDER PRESSURE
2
YES
LINE TEMPERATURE 0.000
Same
ATMOS PRESS 14.73 TEMPERATURE 60° F SPECIFIC GRAVITY 1.0
Same
FLOW COMPUTERTHERMOMETER
96.20
THERMOMETER FLOW COMPUTER
96.20PURCHASER IACX Energy, LLC
0.000
WITNESS SIGNATURE WITNESS DATE
DATECONTACT DATE
COMPANYCONTACT METHOD REVIEWED BY
WITNESS NOTIFICATION
Sam E. Thornhill
REVIEW
0
GOOD
BEVELED PLATE?
500
Gather information and build a new on shore order number 5 compliance report. Calibrated the differential and verified the
static and temperature. Inspected orifice plate it had a thick coating of a white soda ash material on the upstream and
downstream sides of the plate. I was able to clean and inspect plate and put back into service. It appeared the production
plant quit pulling gas from the wells during calibration causing the static pressure to increase on the as left readings.
Updated meter card, saved configuration and process report. Confirmed communications to Scada Lynks.
AS LEFTAS FOUND
ORIFICE PLATE FITTING
METER TUBE ID 2.067
0.8838 SELLER Flatiron Resources LLC
SERIAL # 13180234
Daniel FLANGED TAPS UP STREAM
AS LEFTAS FOUND
STATIC TAP
0.625
DIFFERENCE
PLATE CONDITION
0.000SURFACE CONDITION
GOOD
-0.010 0.00 0.050
180.00
EDGES SHARP?
BEVEL DOWN STREAM?
180.000
BETA RATIO 0.3125
300.000 -0.090
Production Management Measurement, Analytical, Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORT
CALIB RANGE 1 DEVICE RANGE
ACCY MVT
SPAN DP/SP
RTU ADDRESS
LOCATION NO. 100 COUNTY GRAND UTAH
AI # DEVICE RANGE AS Found
KA7233-15P
0.01 BASE PRESS 14.73
FEDERAL LEASE #
DIFFERENTIAL TEST
TRANSDUCER TYPE S7138083JNC
11:30 AM
Same
TEST DEVICE (PSIG)
FLOW COMPUTER (PSIG)FLOW COMPUTER DIFFERENCE
CALIB RANGE
AS LEFT
LIVE STATIC READING 50.802.70
FLOW COMPUTER (PSIG)
12.36AI #
-0.0500
AS FOUND ALLOWABLE THRESHOLD
MVT ACCY OF CAL RANGE in PSI 17.90
0.010
30.090
Same
DIFFERENCE
AS LEFT
AS LEFTSEAL RING CONDITION
400.550
AS FOUND ALLOWABLE THRESHOLD
-50° to +250° F
Do not Test if flowing temp. is ± 0.5° F of test thermometer
FLOW COMPUTERDEVICE FLOW COMPUTERYES
TEMPERATURE TEST500.290
YES
ORIFICE PLATE-0.290
STAMPED SIZE 0.6250
0° to +150° F
400
Good Coated with soda ash material
Same
Sundry Number: 81135 API Well Number: 43019500290000Sundry Number: 81135 API Well Number: 43019500290000
HT Production ManagementMeasurement, Analytical,Automation, Well Testing
Servic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATION NO. 100 COUNTY GRAND STATE UTAH DATE 6/21/2017
o'oASTONMERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 TEEDAESREA UTU87659 API 430-195-002-90000
GPS LOCATION N 39° 11. 221'0" W 109° 8.858" ELEVATION 4955 LAST CEAL 3/16/2017 TIME OF TEST 11:30 AMCOFMLOU
ER WEATHERFORD MAKE K500 ACAAL39L9A2AGNAME OADL TEEAS OK PASS X NSFIXED ED
TRANSDUECER WEATHERFORD CIM NMOMDEELR KA7233-15P SERAR S7138083JNC o.o2s 1.ooFMC
ATMos MONARK MODEL 5696-0321-Cal PREss CRYSTAL MODEL IS336/3000, SER# TEMP THERMOPROBE TL-1W, RTD PlE 211 SER#109653,DEVICE SER# 40000252, CAL DATE 1-19-17 DEVICE 2262-637684, CAL DATE 4-27-16 DEVICE SER#1-WZ4, CAL DATE 1 DEVICE CAL DATE _4-ZZ-1fi
PREss 4.4 TO 17.4 ACCY ACCY PREss 0-3000 PSI ACCY IN PSI 1.5 TEMP ACCY IN OHMS ACCY INRANGE PSI 0.02% IN PSI
0.003 RANGE 0-996.5" H20 0.05% IN H20 0.5 RANGE32°-250° F
0.10% DEG F0.218 RANGE
10-2000 Ohms 0.025% DEG F0.19
DIFFERENTIAL TEST STATIC TESTAl # 0 ZEROESSNDRERFoASd 0.01 L T 0.01 Al # 1 "RASSES 14.73 ARMEOSS 12.36MVTACCY OF CAL 0.10 LIVE DIFF AS 176.60 AS 2.70 MVTACCY OF CAL 0.13 LIVESTATIC AS 17.90 AS 50.80RANGE in INCH H20 READING Found LEFT RANGE in PSI READING Found LEFT
AS FOUND LREWABLED0.510 AS LEFT AS FOUND LREWABLL
1.505 AS LEFTTEST DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER
TEST DEVICE FLOW COMPUTERDIFFERENCE
FLOW COMPUTER(PSIG) (PSIG) (PSIG)
oERMOOS 0 0.010 -0.010 0.00 ZERO 0 0.050 -0.050 SameADPG 180 180.000 0.000 180.00 ASPG 30 30.090 -0.090 Same
JiE 400 400.550 -0.550 400.04 giE 500 500.290 -0.290 Same
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETA RATIO 0.3125 Al # 2 DE CEE
-50° to +250° F RCg 0° to +150° FCONLDTEON Good Coated with soda ash material Do not Test if flowing temp. is ± 0.5° F of test thermometer
sEHDAGRES YES coDIRINGN GOOD AS FOUND LREWABLL
1.018 AS LEFTBELAELEED YES BESTERLDOMWN YES DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER
STAMPEDSIZE 0.6250 CONRD OEN GOOD ZERO 0.000
ORIFICE PLATE FITTING ,AEMG, 0.000
MAKE Daniel TYPE FLANGED TAPS STATIC TAP UP STREAM ágE 0.000SERIAL# 13180234 ,METEERD 2.067 LINE TEMPERATURE
INOSREMCAACN
ATMOSPRESS14.73 TEMPERATURE60 F SPECIFICGRAVITY1.0 AS FOUND AS FOUND AS LEFT AS LEFT"GREACVIYC 0.8838 SELLER Flatiron Resources LLC THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS PURCHASER lACX Energy, LLC 96.20 96.20 Same SameGather information and build a new on shore order number 5 :ompliance report. Calibrated the differential and verified thestatic and temperature. Inspected orifice plate it had a thick coating of a white soda ash material on the upstream anddownstream sides of the plate. I was able to clean and inspect plate and put back into service. It appeared the productionplant quit pulling gas from the wells during calibration causing the static pressure to increase on the as left readings.Updated meter card, saved configuration and process report. Confirmed communications to Scada Lynks.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION REVIEWCONTACT
COMPANY REVIEWED BYMETHOD
CONTACT DATE DATE
WITNESS SIGNATURE NITNESS DATE
RECEIVED: Jun. 23,
Sundry Number: 81135 API Well Number: 43019500290000
HT Production ManagementMeasurement, Analytical,Automation, Well Testing
Servic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATION NO. 100 COUNTY GRAND STATE UTAH DATE 6/21/2017
o'oASTONMERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 TEEDAESREA UTU87659 API 430-195-002-90000
GPS LOCATION N 39° 11. 221'0" W 109° 8.858" ELEVATION 4955 LAST CEAL 3/16/2017 TIME OF TEST 11:30 AMCOFMLOU
ER WEATHERFORD MAKE K500 ACAAL39L9A2AGNAME OADL TEEAS OK PASS X NSFIXED ED
TRANSDUECER WEATHERFORD CIM NMOMDEELR KA7233-15P SERAR S7138083JNC o.o2s 1.ooFMC
ATMos MONARK MODEL 5696-0321-Cal PREss CRYSTAL MODEL IS336/3000, SER# TEMP THERMOPROBE TL-1W, RTD PlE 211 SER#109653,DEVICE SER# 40000252, CAL DATE 1-19-17 DEVICE 2262-637684, CAL DATE 4-27-16 DEVICE SER#1-WZ4, CAL DATE 1 DEVICE CAL DATE _4-ZZ-1fi
PREss 4.4 TO 17.4 ACCY ACCY PREss 0-3000 PSI ACCY IN PSI 1.5 TEMP ACCY IN OHMS ACCY INRANGE PSI 0.02% IN PSI
0.003 RANGE 0-996.5" H20 0.05% IN H20 0.5 RANGE32°-250° F
0.10% DEG F0.218 RANGE
10-2000 Ohms 0.025% DEG F0.19
DIFFERENTIAL TEST STATIC TESTAl # 0 ZEROESSNDRERFoASd 0.01 L T 0.01 Al # 1 "RASSES 14.73 ARMEOSS 12.36MVTACCY OF CAL 0.10 LIVE DIFF AS 176.60 AS 2.70 MVTACCY OF CAL 0.13 LIVESTATIC AS 17.90 AS 50.80RANGE in INCH H20 READING Found LEFT RANGE in PSI READING Found LEFT
AS FOUND LREWABLED0.510 AS LEFT AS FOUND LREWABLL
1.505 AS LEFTTEST DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER
TEST DEVICE FLOW COMPUTERDIFFERENCE
FLOW COMPUTER(PSIG) (PSIG) (PSIG)
oERMOOS 0 0.010 -0.010 0.00 ZERO 0 0.050 -0.050 SameADPG 180 180.000 0.000 180.00 ASPG 30 30.090 -0.090 Same
JiE 400 400.550 -0.550 400.04 giE 500 500.290 -0.290 Same
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETA RATIO 0.3125 Al # 2 DE CEE
-50° to +250° F RCg 0° to +150° FCONLDTEON Good Coated with soda ash material Do not Test if flowing temp. is ± 0.5° F of test thermometer
sEHDAGRES YES coDIRINGN GOOD AS FOUND LREWABLL
1.018 AS LEFTBELAELEED YES BESTERLDOMWN YES DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER
STAMPEDSIZE 0.6250 CONRD OEN GOOD ZERO 0.000
ORIFICE PLATE FITTING ,AEMG, 0.000
MAKE Daniel TYPE FLANGED TAPS STATIC TAP UP STREAM ágE 0.000SERIAL# 13180234 ,METEERD 2.067 LINE TEMPERATURE
INOSREMCAACN
ATMOSPRESS14.73 TEMPERATURE60 F SPECIFICGRAVITY1.0 AS FOUND AS FOUND AS LEFT AS LEFT"GREACVIYC 0.8838 SELLER Flatiron Resources LLC THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS PURCHASER lACX Energy, LLC 96.20 96.20 Same SameGather information and build a new on shore order number 5 :ompliance report. Calibrated the differential and verified thestatic and temperature. Inspected orifice plate it had a thick coating of a white soda ash material on the upstream anddownstream sides of the plate. I was able to clean and inspect plate and put back into service. It appeared the productionplant quit pulling gas from the wells during calibration causing the static pressure to increase on the as left readings.Updated meter card, saved configuration and process report. Confirmed communications to Scada Lynks.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION REVIEWCONTACT
COMPANY REVIEWED BYMETHOD
CONTACT DATE DATE
WITNESS SIGNATURE NITNESS DATE
RECEIVED: Jun. 23,
Sundry Number: 81135 API Well Number: 43019500290000
HT Production ManagementMeasurement, Analytical,Automation, Well Testing
Servic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATION NO. 100 COUNTY GRAND STATE UTAH DATE 6/21/2017
o'oASTONMERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 TEEDAESREA UTU87659 API 430-195-002-90000
GPS LOCATION N 39° 11. 221'0" W 109° 8.858" ELEVATION 4955 LAST CEAL 3/16/2017 TIME OF TEST 11:30 AMCOFMLOU
ER WEATHERFORD MAKE K500 ACAAL39L9A2AGNAME OADL TEEAS OK PASS X NSFIXED ED
TRANSDUECER WEATHERFORD CIM NMOMDEELR KA7233-15P SERAR S7138083JNC o.o2s 1.ooFMC
ATMos MONARK MODEL 5696-0321-Cal PREss CRYSTAL MODEL IS336/3000, SER# TEMP THERMOPROBE TL-1W, RTD PlE 211 SER#109653,DEVICE SER# 40000252, CAL DATE 1-19-17 DEVICE 2262-637684, CAL DATE 4-27-16 DEVICE SER#1-WZ4, CAL DATE 1 DEVICE CAL DATE _4-ZZ-1fi
PREss 4.4 TO 17.4 ACCY ACCY PREss 0-3000 PSI ACCY IN PSI 1.5 TEMP ACCY IN OHMS ACCY INRANGE PSI 0.02% IN PSI
0.003 RANGE 0-996.5" H20 0.05% IN H20 0.5 RANGE32°-250° F
0.10% DEG F0.218 RANGE
10-2000 Ohms 0.025% DEG F0.19
DIFFERENTIAL TEST STATIC TESTAl # 0 ZEROESSNDRERFoASd 0.01 L T 0.01 Al # 1 "RASSES 14.73 ARMEOSS 12.36MVTACCY OF CAL 0.10 LIVE DIFF AS 176.60 AS 2.70 MVTACCY OF CAL 0.13 LIVESTATIC AS 17.90 AS 50.80RANGE in INCH H20 READING Found LEFT RANGE in PSI READING Found LEFT
AS FOUND LREWABLED0.510 AS LEFT AS FOUND LREWABLL
1.505 AS LEFTTEST DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER
TEST DEVICE FLOW COMPUTERDIFFERENCE
FLOW COMPUTER(PSIG) (PSIG) (PSIG)
oERMOOS 0 0.010 -0.010 0.00 ZERO 0 0.050 -0.050 SameADPG 180 180.000 0.000 180.00 ASPG 30 30.090 -0.090 Same
JiE 400 400.550 -0.550 400.04 giE 500 500.290 -0.290 Same
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETA RATIO 0.3125 Al # 2 DE CEE
-50° to +250° F RCg 0° to +150° FCONLDTEON Good Coated with soda ash material Do not Test if flowing temp. is ± 0.5° F of test thermometer
sEHDAGRES YES coDIRINGN GOOD AS FOUND LREWABLL
1.018 AS LEFTBELAELEED YES BESTERLDOMWN YES DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER
STAMPEDSIZE 0.6250 CONRD OEN GOOD ZERO 0.000
ORIFICE PLATE FITTING ,AEMG, 0.000
MAKE Daniel TYPE FLANGED TAPS STATIC TAP UP STREAM ágE 0.000SERIAL# 13180234 ,METEERD 2.067 LINE TEMPERATURE
INOSREMCAACN
ATMOSPRESS14.73 TEMPERATURE60 F SPECIFICGRAVITY1.0 AS FOUND AS FOUND AS LEFT AS LEFT"GREACVIYC 0.8838 SELLER Flatiron Resources LLC THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS PURCHASER lACX Energy, LLC 96.20 96.20 Same SameGather information and build a new on shore order number 5 :ompliance report. Calibrated the differential and verified thestatic and temperature. Inspected orifice plate it had a thick coating of a white soda ash material on the upstream anddownstream sides of the plate. I was able to clean and inspect plate and put back into service. It appeared the productionplant quit pulling gas from the wells during calibration causing the static pressure to increase on the as left readings.Updated meter card, saved configuration and process report. Confirmed communications to Scada Lynks.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION REVIEWCONTACT
COMPANY REVIEWED BYMETHOD
CONTACT DATE DATE
WITNESS SIGNATURE NITNESS DATE
RECEIVED: Jun. 23,
Sundry Number: 81135 API Well Number: 43019500290000
HT Production ManagementMeasurement, Analytical,Automation, Well Testing
Servic es Office: 970-245-2490 Fax: 970-245-2492 P.O.BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATION NO. 100 COUNTY GRAND STATE UTAH DATE 6/21/2017
o'oASTONMERR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 TEEDAESREA UTU87659 API 430-195-002-90000
GPS LOCATION N 39° 11. 221'0" W 109° 8.858" ELEVATION 4955 LAST CEAL 3/16/2017 TIME OF TEST 11:30 AMCOFMLOU
ER WEATHERFORD MAKE K500 ACAAL39L9A2AGNAME OADL TEEAS OK PASS X NSFIXED ED
TRANSDUECER WEATHERFORD CIM NMOMDEELR KA7233-15P SERAR S7138083JNC o.o2s 1.ooFMC
ATMos MONARK MODEL 5696-0321-Cal PREss CRYSTAL MODEL IS336/3000, SER# TEMP THERMOPROBE TL-1W, RTD PlE 211 SER#109653,DEVICE SER# 40000252, CAL DATE 1-19-17 DEVICE 2262-637684, CAL DATE 4-27-16 DEVICE SER#1-WZ4, CAL DATE 1 DEVICE CAL DATE _4-ZZ-1fi
PREss 4.4 TO 17.4 ACCY ACCY PREss 0-3000 PSI ACCY IN PSI 1.5 TEMP ACCY IN OHMS ACCY INRANGE PSI 0.02% IN PSI
0.003 RANGE 0-996.5" H20 0.05% IN H20 0.5 RANGE32°-250° F
0.10% DEG F0.218 RANGE
10-2000 Ohms 0.025% DEG F0.19
DIFFERENTIAL TEST STATIC TESTAl # 0 ZEROESSNDRERFoASd 0.01 L T 0.01 Al # 1 "RASSES 14.73 ARMEOSS 12.36MVTACCY OF CAL 0.10 LIVE DIFF AS 176.60 AS 2.70 MVTACCY OF CAL 0.13 LIVESTATIC AS 17.90 AS 50.80RANGE in INCH H20 READING Found LEFT RANGE in PSI READING Found LEFT
AS FOUND LREWABLED0.510 AS LEFT AS FOUND LREWABLL
1.505 AS LEFTTEST DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER
TEST DEVICE FLOW COMPUTERDIFFERENCE
FLOW COMPUTER(PSIG) (PSIG) (PSIG)
oERMOOS 0 0.010 -0.010 0.00 ZERO 0 0.050 -0.050 SameADPG 180 180.000 0.000 180.00 ASPG 30 30.090 -0.090 Same
JiE 400 400.550 -0.550 400.04 giE 500 500.290 -0.290 Same
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETA RATIO 0.3125 Al # 2 DE CEE
-50° to +250° F RCg 0° to +150° FCONLDTEON Good Coated with soda ash material Do not Test if flowing temp. is ± 0.5° F of test thermometer
sEHDAGRES YES coDIRINGN GOOD AS FOUND LREWABLL
1.018 AS LEFTBELAELEED YES BESTERLDOMWN YES DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER
STAMPEDSIZE 0.6250 CONRD OEN GOOD ZERO 0.000
ORIFICE PLATE FITTING ,AEMG, 0.000
MAKE Daniel TYPE FLANGED TAPS STATIC TAP UP STREAM ágE 0.000SERIAL# 13180234 ,METEERD 2.067 LINE TEMPERATURE
INOSREMCAACN
ATMOSPRESS14.73 TEMPERATURE60 F SPECIFICGRAVITY1.0 AS FOUND AS FOUND AS LEFT AS LEFT"GREACVIYC 0.8838 SELLER Flatiron Resources LLC THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTER
REMARKS PURCHASER lACX Energy, LLC 96.20 96.20 Same SameGather information and build a new on shore order number 5 :ompliance report. Calibrated the differential and verified thestatic and temperature. Inspected orifice plate it had a thick coating of a white soda ash material on the upstream anddownstream sides of the plate. I was able to clean and inspect plate and put back into service. It appeared the productionplant quit pulling gas from the wells during calibration causing the static pressure to increase on the as left readings.Updated meter card, saved configuration and process report. Confirmed communications to Scada Lynks.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION REVIEWCONTACT
COMPANY REVIEWED BYMETHOD
CONTACT DATE DATE
WITNESS SIGNATURE NITNESS DATE
RECEIVED: Jun. 23,
RECEIVED: Sep. 08, 2017
STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS, AND MINING
FORM 9
5.LEASE DESIGNATION AND SERIAL NUMBER: UTU87659
SUNDRY NOTICES AND REPORTS ON WELLS
D o n o t u s e t h i s f o r m f o r p r o p o s a l s t o d r i l l n e w w e l l s , s i g n i f i c a n t l y d e e p e ne x i s t i n g w e l l s b e l o w c u r r e n t b o t t o m - h o l e d e p t h , r e e n t e r p l u g g e d w e l l s , o r t od r i l l h o r i z o n t a l l a t e r a l s . U s e A P P L I C A T I O N F O R P E R M I T T O D R I L L f o r m f o r s u c hp r o p o s a l s .
6 . IF IND IAN, ALLOTTEE OR TRIBE NAME:
7 .UNIT o r CA AGREEMENT NAME:
1. TYPE OF WELL 8. WELL NAME and NUMBER: F l a t i r o n s F e d e r a l 1 - 4
2. NAME OF OPERATOR: FLATIRONS RESOURCES, LLC
9 . AP I NUMBER: 4 3 0 1 9 5 0 0 2 9 0 0 0 0
3. ADDRESS OF OPERATOR: PHONE NUMBER: 11080 CIRCLE POINT ROAD, SUITE 180 , WESTMINSTER, CO, 800202771 3 0 3 - 2 9 2 - 3 9 0 2
9 . F I E L D a n d P O O L o r W I L D C A T : GREATER CISCO
4. LOCATION OF WELLFOOTAGES AT SURFACE: 1402 FNL 757 FELQ T R / Q T R , S E C T I O N , T O W N S H I P , R A N G E , M E R I D I A N : Q t r / Q t r : S E N E S e c t i o n : 4 T o w n s h i p : 1 9 S R a n g e : 2 5 E M e r i d i a n : S
C O U N T Y : GRAND
S T A T E : UTAH
1 1 .
CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
N O T I C E O F I N T E N TA p p r o x i m a t e d a t e w o r k w i l l s t a r t :
9 / 8 / 2 0 1 7
SUBSEQUENT REPORTD a t e o f W o r k C o m p l e t i o n :
SPUD REPORTD a t e o f S p u d :
DRILLING REPORTR e p o r t D a t e :
A C I D I Z E ALTER CASING C A S I N G R E P A I R
CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME
CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE
D E E P E N F R A C T U R E T R E A T NEW CONSTRUCTION
OPERATOR CHANGE PLUG AND ABANDON PLUG BACK
PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE D IFFERENT FORMATION
REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON
T U B I N G R E P A I R VENT OR FLARE WATER DISPOSAL
W A T E R S H U T O F F SI TA STATUS EXTENSION A P D E X T E N S I O N
WILDCAT WELL DETERMINATION OTHER
O T H E R :
C a l i b r a t i o n R e p o r t
1 2 . D E S C R I B E P R O P O S E D O R C O M P L E T E D O P E R A T I O N S . C l e a r l y s h o w a l l p e r t i n e n t d e t a i l s i n c l u d i n g d a t e s , d e p t h s , v o l u m e s , e t c .
c a l i b r a t i o n o n s t a t i c , d i f f e r e n t i a l a n d t e m p e r a t u r e .I n s p e c t e d a n d c l e a n e d o r i f i c e p l a t e . U p d a t e d m e t e r c a r d , s a v e d
c o n f i g u r a t i o n a n d p r o c e s s r e p o r t . C o n f i r m e dc o m m u n i c a t i o n s t o S c a d a L y n x I P 1 6 6 . 1 4 2 . 1 6 7 . 1 8 3 .
N A M E ( P L E A S E P R I N T ) PHONE NUMBER S h a r o n W e l l s 7 2 0 - 6 3 6 - 9 6 3 0
T I T L E S r . E n g r . T e c h
S I G N A T U R E N/A
D A T E 9 / 8 / 2 0 1 7
Sep tember 28 , 2017
Sundry Number: 82622 API Well Number: 43019500290000Sundry Number: 82622 API Well Number: 43019500290000
STATE OF UTAH FORM9
DEPARTMENT OF NATURAL RESOURCESDIVISION OF OIL, GAS, AND MINING 5.LEASE DESIGNATION AND SERIAL NUMBER:
UTU87659
SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
Do not use this form for proposals to drill new wells, significantly deepenexisting wells below current bottom-hole depth, reenter plugged wells, or to 7.uNITorcAAGREEMENTNAME:drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILL form for suchproposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:FLATIRONS RESOURCES, LLC 43019500290000
3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:11080 CIRCLE POINT ROAD, SUITE 180 , WESTMINSTER, CO, 800202771 303-292-39 )23REATER CISCO
4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: GRAND
1402 FNL 757 FELQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:
Qtr/Qtr: SENE Section: 4 Township: 19S Range: 25E Meridian: S UTAH
CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
¿NOTICE OF INTENT ACIDIZE ALTER CASING CASING REPAIR
Approximate date work will start:
9 / 8 / 2 0 1 7 CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME
CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE
OSUBSEQUENT REPORT DEEPEN FRACTURE TREAT NEW CONSTRUCTIONDate of Work Completion:
OPERATOR CHANGE PLUG AND ABANDON PLUG BACK
PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION
OSPUD REPORTDate of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON
TUBING REPAIR VENT OR FLARE WATER DISPOSAL
ODRILLING REPORTWATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSION
Report Date: OTHER:WILDCAT WELL DETERMINATION OTHER
Calibration Report
12. DESCRIBE PROPOSED OR Ct·MPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.calibration on static, differential and temperature.
Inspected and cleaned orifice plate. Updated meter card, saved AcceptedbytheUtah Division ofconfiguration and process report. Confirmed oil,Gasandwiiningcommunications to Scada Lynx IP 166.142.167.183.
NAME (PLEASE PRINT) PHONE NUMBER TITLESharon Wells 720-636-9630 Sr. Engr. Tech
SIGNATURE DATEN/A 9/8/2017
RECEIVED: Sep. 08,
Sundry Number: 82622 API Well Number: 43019500290000
STATE OF UTAH FORM9
DEPARTMENT OF NATURAL RESOURCESDIVISION OF OIL, GAS, AND MINING 5.LEASE DESIGNATION AND SERIAL NUMBER:
UTU87659
SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
Do not use this form for proposals to drill new wells, significantly deepenexisting wells below current bottom-hole depth, reenter plugged wells, or to 7.uNITorcAAGREEMENTNAME:drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILL form for suchproposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:FLATIRONS RESOURCES, LLC 43019500290000
3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:11080 CIRCLE POINT ROAD, SUITE 180 , WESTMINSTER, CO, 800202771 303-292-39 )23REATER CISCO
4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: GRAND
1402 FNL 757 FELQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:
Qtr/Qtr: SENE Section: 4 Township: 19S Range: 25E Meridian: S UTAH
CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
¿NOTICE OF INTENT ACIDIZE ALTER CASING CASING REPAIR
Approximate date work will start:
9 / 8 / 2 0 1 7 CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME
CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE
OSUBSEQUENT REPORT DEEPEN FRACTURE TREAT NEW CONSTRUCTIONDate of Work Completion:
OPERATOR CHANGE PLUG AND ABANDON PLUG BACK
PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION
OSPUD REPORTDate of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON
TUBING REPAIR VENT OR FLARE WATER DISPOSAL
ODRILLING REPORTWATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSION
Report Date: OTHER:WILDCAT WELL DETERMINATION OTHER
Calibration Report
12. DESCRIBE PROPOSED OR Ct·MPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.calibration on static, differential and temperature.
Inspected and cleaned orifice plate. Updated meter card, saved AcceptedbytheUtah Division ofconfiguration and process report. Confirmed oil,Gasandwiiningcommunications to Scada Lynx IP 166.142.167.183.
NAME (PLEASE PRINT) PHONE NUMBER TITLESharon Wells 720-636-9630 Sr. Engr. Tech
SIGNATURE DATEN/A 9/8/2017
RECEIVED: Sep. 08,
Sundry Number: 82622 API Well Number: 43019500290000
STATE OF UTAH FORM9
DEPARTMENT OF NATURAL RESOURCESDIVISION OF OIL, GAS, AND MINING 5.LEASE DESIGNATION AND SERIAL NUMBER:
UTU87659
SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
Do not use this form for proposals to drill new wells, significantly deepenexisting wells below current bottom-hole depth, reenter plugged wells, or to 7.uNITorcAAGREEMENTNAME:drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILL form for suchproposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:FLATIRONS RESOURCES, LLC 43019500290000
3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:11080 CIRCLE POINT ROAD, SUITE 180 , WESTMINSTER, CO, 800202771 303-292-39 )23REATER CISCO
4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: GRAND
1402 FNL 757 FELQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:
Qtr/Qtr: SENE Section: 4 Township: 19S Range: 25E Meridian: S UTAH
CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
¿NOTICE OF INTENT ACIDIZE ALTER CASING CASING REPAIR
Approximate date work will start:
9 / 8 / 2 0 1 7 CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME
CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE
OSUBSEQUENT REPORT DEEPEN FRACTURE TREAT NEW CONSTRUCTIONDate of Work Completion:
OPERATOR CHANGE PLUG AND ABANDON PLUG BACK
PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION
OSPUD REPORTDate of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON
TUBING REPAIR VENT OR FLARE WATER DISPOSAL
ODRILLING REPORTWATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSION
Report Date: OTHER:WILDCAT WELL DETERMINATION OTHER
Calibration Report
12. DESCRIBE PROPOSED OR Ct·MPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.calibration on static, differential and temperature.
Inspected and cleaned orifice plate. Updated meter card, saved AcceptedbytheUtah Division ofconfiguration and process report. Confirmed oil,Gasandwiiningcommunications to Scada Lynx IP 166.142.167.183.
NAME (PLEASE PRINT) PHONE NUMBER TITLESharon Wells 720-636-9630 Sr. Engr. Tech
SIGNATURE DATEN/A 9/8/2017
RECEIVED: Sep. 08,
RECEIVED: Sep. 08, 2017
STATE DATE
100 21
MAKE LEAK TEST OK PASS X NO
PASSFIXED NOT
FIXED
SERIAL NUMBER 0.025%
TEMP
deg F1.00
MVT FC # 1
ATMOS DEVICE
PRESS DEVICE
TEMP DEVICE
RTD DEVICE
1.50.5
0" H2O 400 0 PSIA 15000" H2O 400 0 PSIG 500
0.10 AS Found
AS LEFT 0.13 AS
FoundAS
LEFT
0.510 1.505
ZERO ATOMOS ZERO
AVG DP
AVG SP
FULL RANGE
FULL RANGE
SIZE X AI # 2 DEVICE RANGE
CALIB RANGE
1.018
ZERO
AVG TEMP
MAKE TYPE FULL RANGE
CRYSTAL MODEL IS336/3000, SER# 2262-637684, CAL DATE 4-27-16
THERMOPROBE TL-1W, SER# 1-9574, CAL DATE 10-24-16
PIE 211 SER# 109653,
CAL DATE 4-27-16
STATION OR CUSTOMER
FLOW COMPUTER
9/7/2017
N 39° 11. 221'0" W 109° 8.858" ELEVATION 4955 TIME OF TESTLAST CAL DATE 6/21/2017
CALCULATION METHOD AGA 3 1992, AGA 8 DETAIL
Flatirons Federal #1-4 RTU GROUP
LIVE DIFF READING
UTU87659 API 430-195-002-90000
STATIC TEST
K500WEATHERFORD
WEATHERFORD CIM MODEL NUMBER
ACCY 0.025%
IN DEG F
0.19
-0.01 AS LEFT
MVT ACCY OF CAL RANGE in INCH H20
ATMOS PRESS
TEMP RANGE 32°-250° F ACCY
0.10%IN
DEG F0.218 OHMS
RANGE 10-2000 OhmsPRESS RANGE
GPS LOCATION
MONARK MODEL 5696-0321-Cal SER# 40000252, CAL DATE 1-19-17
BASE CALC INFORMATION
REMARKS
TECHNICIAN SIGNATURE
100
0.160 Same
4.4 TO 17.4 PSI
ACCY0.02%
ACCY IN PSI
0.003 PRESS RANGE
0-3000 PSI 0-996.5" H20
103.30
AS FOUND ALLOWABLE THRESHOLD
ACCY 0.05%
IN PSI IN H20
0
TEST DEVICE FLOW COMPUTER
SPECIFIC GRAVITY
ZER0 UNDER PRESSURE
2
YES
LINE TEMPERATURE 0.000
Same
ATMOS PRESS 14.73 TEMPERATURE 60° F SPECIFIC GRAVITY 1.0
Same
FLOW COMPUTERTHERMOMETER
91.50
THERMOMETER FLOW COMPUTER
91.60PURCHASER IACX Energy, LLC
0.000
WITNESS SIGNATURE WITNESS DATE
DATE 9/8/2017CONTACT DATE
Cathy TheobaldCOMPANY CONTACT METHOD
REVIEWED BY
WITNESS NOTIFICATIONSam E. Thornhill
REVIEW
0
GOOD
BEVELED PLATE?
500
Verified calibration on static, differential and temperature. Inspected and cleaned orifice plate. Updated meter card, saved
configuration and process report. Confirmed communications to Scada Lynx IP 166.142.167.183.
AS LEFTAS FOUND
ORIFICE PLATE FITTING
METER TUBE ID 2.067
0.8838 SELLER Flatiron Resources LLC
SERIAL # 13180234
Daniel FLANGED TAPS UP STREAM
AS LEFTAS FOUND
STATIC TAP
0.625
DIFFERENCE
PLATE CONDITION
0.000SURFACE CONDITION
GOOD
0.030 Same -0.020
Same
EDGES SHARP?
BEVEL DOWN STREAM?
99.910
BETA RATIO 0.3125
140.090 0.010
Production Management Measurement, Analytical, Automation, Well Testing
Office: 970-245-2490 Fax: 970-245-2492 P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORT
CALIB RANGE 1 DEVICE RANGE
ACCY MVT
SPAN DP/SP
RTU ADDRESS
LOCATION NO. 100 COUNTY GRAND UTAH
AI # DEVICE RANGE AS Found
KA7233-15P
-0.02 BASE PRESS 14.73
FEDERAL LEASE #
DIFFERENTIAL TEST
TRANSDUCER TYPE S7138083JNC
11:30 AM
Same
TEST DEVICE (PSIG)
FLOW COMPUTER (PSIG)
FLOW COMPUTER DIFFERENCE
CALIB RANGE
AS LEFT
LIVE STATIC READING 23.80102.90
FLOW COMPUTER (PSIG)
12.36AI #
0.0200
AS FOUND ALLOWABLE THRESHOLD
MVT ACCY OF CAL RANGE in PSI 23.40
-0.030
13.990
Same
DIFFERENCE
AS LEFT
AS LEFTSEAL RING CONDITION
399.840
AS FOUND ALLOWABLE THRESHOLD
-50° to +250° F
Do not Test if flowing temp. is ± 0.5° F of test thermometer
FLOW COMPUTERDEVICE FLOW COMPUTERYES
TEMPERATURE TEST500.030
YES
ORIFICE PLATE-0.030
STAMPED SIZE 0.6250
0° to +150° F
400
Good Coated with soda ash material
Same
Sundry Number: 82622 API Well Number: 43019500290000Sundry Number: 82622 API Well Number: 43019500290000
HT Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATION NO. 100 COUNTY GRAND STATE UTAH DATE 9/7/2017
o'oASTONMEOR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 TEEDAESREA UTU87659 API 430-195-002-90000
GPS LOCATION N 39° 11. 221'0" W 109° 8.858" ELEVATION 4955 LAST CEAL 6/21/2017 TIME OF TEST 11:30 AMCOFMLOU
ER WEATHERFORD MAKE K500 ACAAL39L9A2AGNAM8EHoADL EEAS OK PASS X NA FIXED
TRANSDUECER WEATHERFORD CIM NMODEELR KA7233-15P RR S7138083JNC o.o2s 1.ooFMC
ATMos MONARK MODEL 5696-0321-Cal PREss CRYSTAL MODEL IS336/3000, SER# TEMP THERMOPROBE TL-1W, RTD PlE 211 SER#109fiñ3,DEVICE SER#40000252, CAL DATE 1-19-17 DEVICE 2262-637684, CAL DATE 4-27-16 DEVICE SER#
,CAL DATE 10-24-16 DEVICE CAL DATE 4-27-16
PREss 4.4 TO 17.4 ACCY ACCY PREss 0-3000 PSI ACCY IN PSI 1.5 TEMP ACCY IN OHMS ACCY INRANGE PSI 0.02% IN PSI
0.003RANGE 0-996.5" H20 0.05% IN H20 0.5 RANGE
32°-250° F0.10% DEG F
0.218RANGE
10-2000 Ohms 0.025% DEG F0.19
DIFFERENTIAL TEST STATIC TESTAl # 0 ZERROESSNDREEFoASd -0.01
L T-0.02 Al # 1 R
SES 14.73 ARMEOSS 12.36MVTACCY OF CAL 0.10 LIVE DIFF AS 103.30 AS 102.90 MVTACCY OF CAL 0.13 LIVESTATIC AS 23.40 AS 23.80RANGE in INCH H20 READING Found LEFT RANGE in PSI READING Found LEFT
AS FOUND LREWAB_ED0.51 AS LEFT AS FOUND LREWABL
1.50 AS LEFTTEST DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER TEST DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER
(PSIG) (PSIG) (PSIG)oERMOOS 0 -0.030 0.030 Same ZERO 0 -0.020 0.020 Same
ADPG 100 99.910 0.090 Same ASPG 14 13.990 0.010 Same
JiE 400 399.840 0.160 Same JiE 500 500.030 -0.030 Same
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETA RATIO 0.3125 Al # 2 DRE CEE -50° to +250° F RC BE 0° to +150° FCONLDTEON Good Coated with soda ash material Do not Test if flowing temp. is ± 0.5° F of test thermometer
sEHDAGRES YES SE DIRINGN GOOD AS FOUND LREWABL1.018 AS LEFT
BELAELEED YES BESTERLEDAMWN YES DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER
STAMPEDSIZE 0.6250 CONRDFACEN GOOD ZERO 0.000
ORIFICE PLATE FITTING ,AEMG, 0.000MAKE Daniel TYPE FLANGEDTAPS STATICTAP UPSTREAM JiE 0.000
SERIAL# 13180234 -METEERD 2.067 LINE TEMPERATUREINFASRECAACN
ATMOSPRESS14.73 TEMPERATURE60 F SPECIFICGRAVITY1.0 AS FOUND AS FOUND AS LEFT AS LEFTSPECIFIC 0.8838 SELLER Flatiron Resources LLC THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTERGRAVITY
REMARKS PURCHASER lACX Energy, LLC 91.60 91.50 Same SameVerified calibration on static, differential and temperature. In.:pected and cleaned orifice plate. Updated meter card, savedconfiguration and process report. Confirmed communications to Scada Lynx IP 166.142.167.183.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION REVIEWCOMPANY CMENACD REVIEWED BY
CONTACT DATE DATE 9/8/2017WITNESS SIGNATURE NITNESS DATE
RECEIVED: Sep. 08,
Sundry Number: 82622 API Well Number: 43019500290000
HT Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATION NO. 100 COUNTY GRAND STATE UTAH DATE 9/7/2017
o'oASTONMEOR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 TEEDAESREA UTU87659 API 430-195-002-90000
GPS LOCATION N 39° 11. 221'0" W 109° 8.858" ELEVATION 4955 LAST CEAL 6/21/2017 TIME OF TEST 11:30 AMCOFMLOU
ER WEATHERFORD MAKE K500 ACAAL39L9A2AGNAM8EHoADL EEAS OK PASS X NA FIXED
TRANSDUECER WEATHERFORD CIM NMODEELR KA7233-15P RR S7138083JNC o.o2s 1.ooFMC
ATMos MONARK MODEL 5696-0321-Cal PREss CRYSTAL MODEL IS336/3000, SER# TEMP THERMOPROBE TL-1W, RTD PlE 211 SER#109fiñ3,DEVICE SER#40000252, CAL DATE 1-19-17 DEVICE 2262-637684, CAL DATE 4-27-16 DEVICE SER#
,CAL DATE 10-24-16 DEVICE CAL DATE 4-27-16
PREss 4.4 TO 17.4 ACCY ACCY PREss 0-3000 PSI ACCY IN PSI 1.5 TEMP ACCY IN OHMS ACCY INRANGE PSI 0.02% IN PSI
0.003RANGE 0-996.5" H20 0.05% IN H20 0.5 RANGE
32°-250° F0.10% DEG F
0.218RANGE
10-2000 Ohms 0.025% DEG F0.19
DIFFERENTIAL TEST STATIC TESTAl # 0 ZERROESSNDREEFoASd -0.01
L T-0.02 Al # 1 R
SES 14.73 ARMEOSS 12.36MVTACCY OF CAL 0.10 LIVE DIFF AS 103.30 AS 102.90 MVTACCY OF CAL 0.13 LIVESTATIC AS 23.40 AS 23.80RANGE in INCH H20 READING Found LEFT RANGE in PSI READING Found LEFT
AS FOUND LREWAB_ED0.51 AS LEFT AS FOUND LREWABL
1.50 AS LEFTTEST DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER TEST DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER
(PSIG) (PSIG) (PSIG)oERMOOS 0 -0.030 0.030 Same ZERO 0 -0.020 0.020 Same
ADPG 100 99.910 0.090 Same ASPG 14 13.990 0.010 Same
JiE 400 399.840 0.160 Same JiE 500 500.030 -0.030 Same
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETA RATIO 0.3125 Al # 2 DRE CEE -50° to +250° F RC BE 0° to +150° FCONLDTEON Good Coated with soda ash material Do not Test if flowing temp. is ± 0.5° F of test thermometer
sEHDAGRES YES SE DIRINGN GOOD AS FOUND LREWABL1.018 AS LEFT
BELAELEED YES BESTERLEDAMWN YES DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER
STAMPEDSIZE 0.6250 CONRDFACEN GOOD ZERO 0.000
ORIFICE PLATE FITTING ,AEMG, 0.000MAKE Daniel TYPE FLANGEDTAPS STATICTAP UPSTREAM JiE 0.000
SERIAL# 13180234 -METEERD 2.067 LINE TEMPERATUREINFASRECAACN
ATMOSPRESS14.73 TEMPERATURE60 F SPECIFICGRAVITY1.0 AS FOUND AS FOUND AS LEFT AS LEFTSPECIFIC 0.8838 SELLER Flatiron Resources LLC THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTERGRAVITY
REMARKS PURCHASER lACX Energy, LLC 91.60 91.50 Same SameVerified calibration on static, differential and temperature. In.:pected and cleaned orifice plate. Updated meter card, savedconfiguration and process report. Confirmed communications to Scada Lynx IP 166.142.167.183.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION REVIEWCOMPANY CMENACD REVIEWED BY
CONTACT DATE DATE 9/8/2017WITNESS SIGNATURE NITNESS DATE
RECEIVED: Sep. 08,
Sundry Number: 82622 API Well Number: 43019500290000
HT Production ManagementMeasurement, Analytical,Automation, Well Testing
Ser vic es Office: 970-245-2490 Fax: 970-245-2492P.O. BOX 3866 Grand Junction, CO 81501
FLATIRON RESOURCES LLC - ELECTRONIC FLOW MEASUREMENT CALIBRATION REPORTLOCATION NO. 100 COUNTY GRAND STATE UTAH DATE 9/7/2017
o'oASTONMEOR Flatirons Federal #1-4 RTU ADDRESS 100 RTU GROUP 21 TEEDAESREA UTU87659 API 430-195-002-90000
GPS LOCATION N 39° 11. 221'0" W 109° 8.858" ELEVATION 4955 LAST CEAL 6/21/2017 TIME OF TEST 11:30 AMCOFMLOU
ER WEATHERFORD MAKE K500 ACAAL39L9A2AGNAM8EHoADL EEAS OK PASS X NA FIXED
TRANSDUECER WEATHERFORD CIM NMODEELR KA7233-15P RR S7138083JNC o.o2s 1.ooFMC
ATMos MONARK MODEL 5696-0321-Cal PREss CRYSTAL MODEL IS336/3000, SER# TEMP THERMOPROBE TL-1W, RTD PlE 211 SER#109fiñ3,DEVICE SER#40000252, CAL DATE 1-19-17 DEVICE 2262-637684, CAL DATE 4-27-16 DEVICE SER#
,CAL DATE 10-24-16 DEVICE CAL DATE 4-27-16
PREss 4.4 TO 17.4 ACCY ACCY PREss 0-3000 PSI ACCY IN PSI 1.5 TEMP ACCY IN OHMS ACCY INRANGE PSI 0.02% IN PSI
0.003RANGE 0-996.5" H20 0.05% IN H20 0.5 RANGE
32°-250° F0.10% DEG F
0.218RANGE
10-2000 Ohms 0.025% DEG F0.19
DIFFERENTIAL TEST STATIC TESTAl # 0 ZERROESSNDREEFoASd -0.01
L T-0.02 Al # 1 R
SES 14.73 ARMEOSS 12.36MVTACCY OF CAL 0.10 LIVE DIFF AS 103.30 AS 102.90 MVTACCY OF CAL 0.13 LIVESTATIC AS 23.40 AS 23.80RANGE in INCH H20 READING Found LEFT RANGE in PSI READING Found LEFT
AS FOUND LREWAB_ED0.51 AS LEFT AS FOUND LREWABL
1.50 AS LEFTTEST DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER TEST DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER
(PSIG) (PSIG) (PSIG)oERMOOS 0 -0.030 0.030 Same ZERO 0 -0.020 0.020 Same
ADPG 100 99.910 0.090 Same ASPG 14 13.990 0.010 Same
JiE 400 399.840 0.160 Same JiE 500 500.030 -0.030 Same
ORIFICE PLATE TEMPERATURE TESTSIZE 2 X 0.625 BETA RATIO 0.3125 Al # 2 DRE CEE -50° to +250° F RC BE 0° to +150° FCONLDTEON Good Coated with soda ash material Do not Test if flowing temp. is ± 0.5° F of test thermometer
sEHDAGRES YES SE DIRINGN GOOD AS FOUND LREWABL1.018 AS LEFT
BELAELEED YES BESTERLEDAMWN YES DEVICE FLOW COMPUTER DIFFERENCE FLOW COMPUTER
STAMPEDSIZE 0.6250 CONRDFACEN GOOD ZERO 0.000
ORIFICE PLATE FITTING ,AEMG, 0.000MAKE Daniel TYPE FLANGEDTAPS STATICTAP UPSTREAM JiE 0.000
SERIAL# 13180234 -METEERD 2.067 LINE TEMPERATUREINFASRECAACN
ATMOSPRESS14.73 TEMPERATURE60 F SPECIFICGRAVITY1.0 AS FOUND AS FOUND AS LEFT AS LEFTSPECIFIC 0.8838 SELLER Flatiron Resources LLC THERMOMETER FLOW COMPUTER THERMOMETER FLOW COMPUTERGRAVITY
REMARKS PURCHASER lACX Energy, LLC 91.60 91.50 Same SameVerified calibration on static, differential and temperature. In.:pected and cleaned orifice plate. Updated meter card, savedconfiguration and process report. Confirmed communications to Scada Lynx IP 166.142.167.183.
TECHNICIAN SIGNATURE
WITNESS NOTIFICATION REVIEWCOMPANY CMENACD REVIEWED BY
CONTACT DATE DATE 9/8/2017WITNESS SIGNATURE NITNESS DATE
RECEIVED: Sep. 08,
RECEIVED: May. 10, 2018
STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS, AND MINING
FORM 9
5.LEASE DESIGNATION AND SERIAL NUMBER: UTU87659
SUNDRY NOTICES AND REPORTS ON WELLSDo not use this form for proposals to drill new wells, significantly deepen existing wellsbelow current bottom-hole depth, reenter plugged wells, or to drill horizontal laterals.Use APPLICATION FOR PERMIT TO DRILL form for such proposals.
6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
7.UNIT or CA AGREEMENT NAME:
1. TYPE OF WELL
8. WELL NAME and NUMBER: Flatirons Federal 1-4
2. NAME OF OPERATOR: FLATIRONS RESOURCES, LLC
9. API NUMBER: 43019500290000
3. ADDRESS OF OPERATOR: PHONE NUMBER: 11080 CIRCLE POINT ROAD, SUITE 180 , WESTMINSTER, CO, 800202771 303-292-3902
9. FIELD and POOL or WILDCAT: GREATER CISCO
4. LOCATION OF WELL FOOTAGES AT SURFACE: 1402 FNL 757 FEL QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: Qtr/Qtr: SENE Section: 4 Township: 19S Range: 25E Meridian: S
COUNTY: GRAND
STATE: UTAH
11.CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OFSUBMISSION TYPE OF ACTION
NOTICE OF INTENTApproximate date work will start:
SUBSEQUENT REPORTDate of Work Completion:
3/31/2018
SPUD REPORTDate of Spud:
DRILLING REPORTReport Date:
ACIDIZE ALTER CASING CASING REPAIR
CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME
CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE
DEEPEN FRACTURE TREAT NEW CONSTRUCTION
OPERATOR CHANGE PLUG AND ABANDON PLUG BACK
PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION
REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON
TUBING REPAIR VENT OR FLARE WATER DISPOSAL
WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSION
WILDCAT WELL DETERMINATION OTHER OTHER:
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc. This well was shut-in March 31st as a result of uneconomic production caused bya net drop in Helium price effective January 1st, 2018. Currently there appears tobe a tightening in the Helium market and we are optimistic that the net price of
Helium with return to last year’s levels within the next 6 months. If that occurs theprocessor has indicated they be ready to restart the processing plant and the well
will be put back into production.
NAME (PLEASE PRINT) PHONE NUMBER Jeffery E. Jones 303 292-3902
TITLE Managing Director
SIGNATURE N/A
DATE 5/10/2018
September 05, 2018
Sundry Number: 88018 API Well Number: 43019500290000Sundry Number: 88018 API Well Number: 43019500290000
FORM 9STATE OF UTAH
DEPARTMENT OF NATURAL RESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTU87659
SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wellsbelow current bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. 7.UNIT or CA AGREEMENT NAME:
Use APPLICATION FOR PERMIT TO DRILL form for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:FLATIRONS RESOURCES, LLC 43019500290000
3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:11080 CIRCLE POINT ROAD, SUITE 180 , WESTMINSTER, CO, 800202771 303-292-296REATER CISCO
4. LOCATION OF WELL COUNTY:FOOTAGES AT SURFACE: GRAND
1402 FNL 757 FELQTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:
Qtr/Qtr:SENE Section: 4 Township: 19S Range: 25E Meridian: S UTAH
11.CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF TYPE OF ACTIONSUBMISSION
ACIDIZE ALTER CASING CASING REPAIR
NOTICE OF INTENTApproximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME
CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE
SUBSEQUENT REPORTDate of Work Completion: DEEPEN FRACTURE TREAT NEW CONSTRUCTION
3/31/20 18OPERATOR CHANGE PLUG AND ABANDON PLUG BACK
SPUD REPORTPRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION
Date of Spud:REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON
TUBING REPAIR VENT OR FLARE WATER DISPOSAL
DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:
WILDCAT WELL DETERMINATION OTHER OTHER:
12. DESCRIBE PROPOSE ) OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.This well was shut-in March 31st as a result of uneconomic production caused bya net drop in Helium price effective January 1st, 2018. Currently there appears to Accepted by the
be a tightening in the Helium market and we are optimistic that the net price of Utah Division ofHelium with return to last year's levels within the next 6 months. If that occurs the Oil, Gas and Miningprocessor has indicated they be ready to restart the processing plant and the well FOR RECORD ONLY
will be put back into production.September 05, 2018
NAME (PLEASE PRINT) PHONE NUMBER TITLEJeffery E. Jones 303 292-3902 Managing Director
SIGNATURE DATEN/A 5/10/2018
RECEIVED: May. 10,
Sundry Number: 88018 API Well Number: 43019500290000
FORM 9STATE OF UTAH
DEPARTMENT OF NATURAL RESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTU87659
SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wellsbelow current bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. 7.UNIT or CA AGREEMENT NAME:
Use APPLICATION FOR PERMIT TO DRILL form for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:FLATIRONS RESOURCES, LLC 43019500290000
3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:11080 CIRCLE POINT ROAD, SUITE 180 , WESTMINSTER, CO, 800202771 303-292-296REATER CISCO
4. LOCATION OF WELL COUNTY:FOOTAGES AT SURFACE: GRAND
1402 FNL 757 FELQTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:
Qtr/Qtr:SENE Section: 4 Township: 19S Range: 25E Meridian: S UTAH
11.CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF TYPE OF ACTIONSUBMISSION
ACIDIZE ALTER CASING CASING REPAIR
NOTICE OF INTENTApproximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME
CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE
SUBSEQUENT REPORTDate of Work Completion: DEEPEN FRACTURE TREAT NEW CONSTRUCTION
3/31/20 18OPERATOR CHANGE PLUG AND ABANDON PLUG BACK
SPUD REPORTPRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION
Date of Spud:REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON
TUBING REPAIR VENT OR FLARE WATER DISPOSAL
DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:
WILDCAT WELL DETERMINATION OTHER OTHER:
12. DESCRIBE PROPOSE ) OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.This well was shut-in March 31st as a result of uneconomic production caused bya net drop in Helium price effective January 1st, 2018. Currently there appears to Accepted by the
be a tightening in the Helium market and we are optimistic that the net price of Utah Division ofHelium with return to last year's levels within the next 6 months. If that occurs the Oil, Gas and Miningprocessor has indicated they be ready to restart the processing plant and the well FOR RECORD ONLY
will be put back into production.September 05, 2018
NAME (PLEASE PRINT) PHONE NUMBER TITLEJeffery E. Jones 303 292-3902 Managing Director
SIGNATURE DATEN/A 5/10/2018
RECEIVED: May. 10,
RECEIVED: Sep. 06, 2018
FEDERAL APPROVAL OF THIS ACTION IS NECESSARY
STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES
DIVISION OF OIL, GAS, AND MINING
FORM 9
5.LEASE DESIGNATION AND SERIAL NUMBER: UTU87659
SUNDRY NOTICES AND REPORTS ON WELLSDo not use this form for proposals to drill new wells, significantly deepen existing wellsbelow current bottom-hole depth, reenter plugged wells, or to drill horizontal laterals.Use APPLICATION FOR PERMIT TO DRILL form for such proposals.
6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
7.UNIT or CA AGREEMENT NAME:
1. TYPE OF WELL
8. WELL NAME and NUMBER: Flatirons Federal 1-4
2. NAME OF OPERATOR: FLATIRONS RESOURCES, LLC
9. API NUMBER: 43019500290000
3. ADDRESS OF OPERATOR: PHONE NUMBER: 11080 CIRCLE POINT ROAD, SUITE 180 , WESTMINSTER, CO, 800202771 303-292-3902
9. FIELD and POOL or WILDCAT: GREATER CISCO
4. LOCATION OF WELL FOOTAGES AT SURFACE: 1402 FNL 757 FEL QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: Qtr/Qtr: SENE Section: 4 Township: 19S Range: 25E Meridian: S
COUNTY: GRAND
STATE: UTAH
11.CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
NOTICE OF INTENTApproximate date work will start:
10/25/2018
SUBSEQUENT REPORTDate of Work Completion:
SPUD REPORTDate of Spud:
DRILLING REPORTReport Date:
ACIDIZE ALTER CASING CASING REPAIR
CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME
CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE
DEEPEN FRACTURE TREAT NEW CONSTRUCTION
OPERATOR CHANGE PLUG AND ABANDON PLUG BACK
PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION
REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON
TUBING REPAIR VENT OR FLARE WATER DISPOSAL
WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSION
WILDCAT WELL DETERMINATION OTHER OTHER:
12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc. Attached is the approved Federal Sundry with plugging procedures for the well.
NAME (PLEASE PRINT) PHONE NUMBER Jeffery E. Jones 303 292-3902
TITLE Managing Director
SIGNATURE N/A
DATE 9/6/2018
September 27, 2018
Sundry Number: 90452 API Well Number: 43019500290000Sundry Number: 90452 API Well Number: 43019500290000FEDERAL APPROVAL OF THIS ACTION IS NECESSARY
FORM 9STATE OF UTAH
DEPARTMENT OF NATURAL RESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTU87659
SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:
Do not use this form for proposals to drill new wells, significantly deepen existing wellsbelow current bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. 7.UNIT or CA AGREEMENT NAME:
Use APPLICATION FOR PERMIT TO DRILL form for such proposals.
1. TYPE OF WELL 8. WELL NAME and NUMBER:Flatirons Federal 1-4
2. NAME OF OPERATOR: 9. API NUMBER:FLATIRONS RESOURCES, LLC 43019500290000
3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:11080 CIRCLE POINT ROAD, SUITE 180 , WESTMINSTER, CO, 800202771 303-292-296REATER CISCO
4. LOCATION OF WELL COUNTY:FOOTAGES AT SURFACE: GRAND
1402 FNL 757 FELQTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:
Qtr/Qtr:SENE Section: 4 Township: 19S Range: 25E Meridian: S UTAH
11.
CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
/ NOTICE OF INTENTACIDIZE ALTER CASING CASING REPAIR
Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME
10/25/2018CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE
SUBSEQUENT REPORT DEEPEN FRACTURE TREAT NEW CONSTRUCTIONDate of Work Completion:
OPERATOR CHANGE PLUG AND ABANDON PLUG BACK
PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION
SPUD REPORTDate of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON
TUBING REPAIR VENT OR FLARE WATER DISPOSAL
DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSION
Report Date:WILDCAT WELL DETERMINATION OTHER OTHER:
12. DESCRIBE PROPOSED )R COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.Attached is the approved Federal Sundry with plugging procedures for the well· Approved by the
Utah Division ofOil, Gas and Mining
Date: September 27, 2018
NAME (PLEASE PRINT) PHONE NUMBER TITLEJeffery E. Jones 303 292-3902 Managing Director
SIGNATURE DATEN/A 9/6/2018
RECEIVED: Sep. 06,
RECEIVED: Sep. 06, 2018
Sundry Number: 90452 API Well Number: 43019500290000Sundry Number: 90452 API Well Number: 43019500290000
"" a UNITEDSTATES e .og
DEPARTMENTOF THEINTERIOR Enrires January3L2018BUREAU OF LAND MANAGEMENT 5 1.rasesenal No (ITU67659
SUNDRY NOTICES AND REPORTS ONWELLS 6 frinden AlfoncecrTnbeNameDo not use this form for proposals to drill or to re-enter an
abandoned well.Use Form 3160-3 (APD)for such proposals.SUBMir/NTRIPL.JCATE-Otherinstrucdonsonpage2 i RUmlerõÙAgreemcru,NamedorÑo
I TypcofWC11
O:I Well GasWell O Düler i W:ÑNameand No Flaikons Fedoral #1-42 Nameof0perator Flaurons ResourtasLLC 430195002900003a Addrcss 11080Ckde Pt Road.Sulle 150 3b l1mncNu (Jacisstr arra cade; k heldatàPoelor asploraloryAren
WestmhtstorCO 80020 (72B}E36-9624 Graaler Cisco4 Lo¢nuanofWe11(FootageSer TR Al or5ung Deuriprian) 11 Counuyorhmh state
1402' FNL,75TFELSection4, T195, R25E PAYSW Grand County
12 CHECKTHEAPPROPRJATEDOX(CS)]DINDICATENAli)REOFNOTICERErokTDROTIIERDATA
TYPEOFSUDMISSION TYPEOFAcilON
Nonceof Inlen1 Aem• De pen Q Produchen(5¾Rw) Waer Shui.OffOsu=,casas On*==wFr-a OR=I=m=ton O veillwe
SubsequenlRepon CasingRepm NmConsuuchon Rmpi 0 erChangeINarts Plugand Abadon TunpomnlyAbandon
O Finübandomen1 NN ce Comm La I n PlugDaß WaterDisposat!) DesenbcIYoposeder CompleledOper:nionCle=rlyslaleall perunentdetails,meh:ding estmied starungdaicofany poposed unrk andapproximateduralen Ibereof If
the proposalis todeependetectiorullyor recompitre horizontallygivesubsurface locaticasand measured and true vertical depthsatall pettmentmarkers am]tones Anachthe Bandunder ohteh theworkmil beperfonnedor prot ide theBondNo on filewith BLht/BIA Rcquurdsubsequeni reports mustbc filedmthin 30days fol[owingcompicilon of the mvahedop:taisons If ihe operation resultsm a muluple completon or recompletson m a new tnierval, a Fwm3160-1musibefiledonce testmghasbeencompt:led FmalAt=mdanment Notices trittst be filcLIOft y DÛ¢fAl FCQUlfEffitfil! Inc Uding ICC af!32(laItavebeenenirspletedaral titeoperaler Wdelerintacd 11·.21Ilicai'eis readyforfinalinspe:IIcn )AddillanalwellInformation:':PCS
enno lag =m CONDOONSOFAPPROVALATTACHED3.Perforated(OpenHola)1nterval. 856.954'4. Top ofEntrado .855Fl; lop Seltwash 577 FI5- Shutinwetihead pressure•60 PSIIWCubic feelto lincashtgfromPETD tosurface with 15% excess 238 Fl*3er 42 BbisThiswet!wn!plugged as follows
a. Pump 10 Bblewaler downcasing tokit wellb. Runningin theholewilhlubing to30 feel above thelop ofEntradae Pump sufficianicement loplace a balanced plug inside thebottom500 feel of castr.gd. Tripout of hoto to top of cement and pumpicirculatesufficien!Io completely fd1hole withcemente. Tripout of hole 1elcement set over nightf. Place dry holemarker in top ofcasingand topolfcomentg, Racialmsurface lo originalcontours and resoed withthe followingseed mlx IndianRice Grass 1 Lblaere.b Cortey Grass i lblacroGlobeMallowForbs 1 Lblacto,andshmbs consistingof Hadscale and WinterFat 1 Lblacre
WorkwBlcommencein0etabar201B
ÏÏi Ob certi(ythatthe fortsome istmeami carrrei Name(Primrd7)ped)Jeffery E. Jones ManagingDiraclor
Sigranit: - Dale 08/15/2018
THESPACEFOR FEDERALOR STATE OFICE USE
Cond s of approval, if any,mz nilached. Approval of dus noticedoesnotwararA ore th21theoppheant holdslegalor equitable tideto those r shLI mthesub CCi Icas: (Bzewhich wouldennlic ihe apphcant toconduct operanans thereon
Tide 15U 5 C Settien 1001und Title43 U5 C Section1211makena enmeforanypersonknomnglyand milfullyto make lo anydeputmenter agency of the LinnedStateany inise,llentmusorfraudulentstatementsor representations as la any matter othm histunsdicuan
(Instruellons on page 2)
AWwew/co cM¿«s n'
RECEIVED: Sep. 06, 2018
Sundry Number: 90452 API Well Number: 43019500290000Sundry Number: 90452 API Well Number: 43019500290000
CONDITIONS OF APPROVAL FOR WELL ABANDONMENT
Company Flatirons ResourcesLeaseNo. UTU-87659Location: Sec 4, T19S, R25EWell No. Lansdale-Govt #1-4API No. 43-019-50029
GOVERNMENT CONTACTSBUREAU OF LAND MANAGEMENT - MOAB FIELD OFFICE
82 Dogwood Ave, Moab, Utah 84532 (435) 259-2100
Petroleum Engineer:Rachel Knell Cell: 776-6755 Office: 781-4419I&E Inspector: Jeff Brown Cell: 459-4886 Office: 587-1525
A COPY OF THESE CONDITIONS SHALL BE GIVEN TOYOUR FIELD REPRESENTATIVE TO ENSURE COMPLIANCE
SITE SPECIFIC DOWNHOLE CONDITIONS OF APPROVAL
1. After setting the first 500' plug, please tag.2. Set the second portion of the plug as proposed.3. Bring the cement in the annulus between the 8 3 " hole and 7" casing up to the surface.
STANDARD SURFACE CONDITION OF APPROVAL
1. Within30 days after plugging the well, a Sundry Subsequent Report will be submitted forapproval detailing the plugging operations.
STANDARD CONDITIONS OF APPROVAL
You must initiate plugging operations within 1 year after the approval of this Notice of Intentto Abandon. This approval will expire at that time.
1. Notify the BLM sufficiently in advance of actual plugging work so that a representative mayhave an opportunity to witness the operation. Notify Jeff Brown on a regular working day(Monday throughFriday) at least 24 hours in advance of rigging up.
2. Unless otherwise directed, prior to setting any plugs or perforating, you will perform a bit andscraper run. After the perforations are sealed, you wíll perform a hot oil treatment, paraffinremoval operation, or whatever well cleanout operations are deemed necessary. You willcirculate the well surface to the surface.
3. Prior to perforating any casing string, you will open up the bradenhead and install and secureadequate BOPs, lubricators, and
RECEIVED: Sep. 06, 2018
Sundry Number: 90452 API Well Number: 43019500290000Sundry Number: 90452 API Well Number: 43019500290000
4. All cement used for plugging shall be Class "G". Cement samples will be taken to determineappropriate waiting time.
5. All perforations must be covered with cement unless they are isolated by a CIBP or a CICR.The BLM will determine which plugs must be tagged.
6. After the perforationsare isolated, the well will be pressure-tested to 500 psi with no more than a50 psi loss allowed. If the well fails the pressure test, you must find the holes in the casing andisolate them.
7. Cased hole spacer fluid will include conosion inhibitorand biocide to be compatible with thecement. Fresh water spacers will be run between the cement and the inhibitor/biocide.
8. If you cannot circulate cement from the perforations 50' below the surface casing shoe, you willpropose a revised procedure to ensure there is cement to the surface in the annulus as well as inthe casing.
9. Cementwill be toppedoff as needed.
10. A GPS re-verification and certification of the abandoned well locationshall be made for theLatitude and Longitude coordinates with accuracy to the sixth decimal place. This well locationre-verification shall be noted on the SubsequentSundry Notice of Abandonment.
11. Wait on Cement for a minimum of24 hours followingthe approved plugging program beforeinstallingthedry hole marker in accordance with 43 CFR 3162.6(b). The site will be cleaned upby removingequipment and debris.
12. Unless otherwise directed by the Surface Management Entity, the marker shall be a flat plate(with a weep hole) not less than 1/4 inch in thickness and large enough to contain all of theinformationidentifiedbelow and shall be buried a minimum of three (3) foot below re-contouredsurface level. Pits must be fencedunless otherwise approvedby the authorized officer.
13. The following minimuminformationwill be permanently and legibly placed on the marker witha plate, cap or welded bead:
A. Name of the operator.B. Lease serial number.C. Well number.D. Surveyed descriptionof the well; section, township and range and either footages or
quarter-quarter section.
14. Within 30 days after well bore plugging operations have been completed, Form 3160-5 (formerlyForm 9-331), Subsequent Report of Abandonment, shall be submitted to this office. The reportmust show the location of all plugs or any mechanical setting device, quantity and type ofcement and additives in each plug, amount of casing or any tubulars left in the hole, methodsused to test plugs and test results, and the status of the surface restoration. If a temporarydelay
RECEIVED: Sep. 06, 2018
Sundry Number: 90452 API Well Number: 43019500290000Sundry Number: 90452 API Well Number: 43019500290000
the removal of equipment or surface cleanup is deemed necessary, so justifyin your report. Thisabandonment report will be approved by this office with surface stipulations. Liability for thewell shall not be released until the surface management agency approves the actual siterehabilitation.
15. If not previously filed, submit in duplicate,Form 3160-4 (formerlyForm 9-330), Wellcompletion or Recompletion Report and Log,well history,electric logs, any other surveys,and,if taken, core analysis. This completion report must be filedwithin 30 days after the culminationof downholeplugging
RECEIVED: Sep. 06, 2018
Sundry Number: 90452 API Well Number: 43019500290000Sundry Number: 90452 API Well Number: 43019500290000
abo,s &mrem Fa+nns FederdRg : wo e- ScoasSpud:8/0 e
Is"hob
bu bde, +o 905''To
RECEIVED: Sep. 06, 2018
Sundry Number: 90452 API Well Number: 43019500290000Sundry Number: 90452 API Well Number: 43019500290000
WELLBOREDIAGRAM
weil:Flatirons Federal#1-4 County/State:GrandCounty.UTAH Formation:Entrada
Field:Harley Dame Location: Se¢4-T195·R25E Date: August 13, 20131402 FNL,757 FEL
APINo.-43019500290000 Lease Serial No. UTUS7659
Conductor Pipe@50', 14", 55 R2butt weld CSG/ Hole size =17 V7
Flow test for the Morrison 577'-595'(note· a slight leaked in the rotating headmayhave influenced the shut ins) 263'1" shut in 15 mins--wellbuilt to 88 Ibs,andstill buildina 9 5/8", 32.315,R-3,LTC,H-40surfacecasing
Opened well for 15 mins@95% flowed at @263.66' cementwith 65 sacks of Class G70lbs with a rate of 350 MCFPD with Celloflake, Extender and anti-foam2ndShut in 15 mins-well built to 89.1additive . 5 bbi circulated to surfaceand stillbuilding
Opened well for 15 mins and flowed at51.3 pounds at a rate of 700 MCFPD3" Shut in for 15 mins-well built to 89.6
7', 2611,STC,LTC,J-55 casing@866' withand st|Il building81 sacks of Class G cement with Cellaflake,Opened well to free flow well built to
1.2 MMCFPD@19 P51 Extender and anti-foam additive. S bbicirculated to surface
. . L 866'
Entrada Flow Tests wb|le Drilling
875'-905' 750 mcf 51/52*
87S'-920' 2400 mcf 51/52+ 6 "openhole below 7" casing
875'-935' 2954 mcf 163875'-950' 3985 mcf 161*
TD = 965'875'-965' 4155 mcf 161*
Flatirons Resources