Protein Interaction Analysis - Akademilabakademilab.com.tr/bilgibankasi/bio-rad/Protein Interaction...

Post on 06-Feb-2018

236 views 0 download

Transcript of Protein Interaction Analysis - Akademilabakademilab.com.tr/bilgibankasi/bio-rad/Protein Interaction...

  • www.bio-rad.com/proteininteraction/

    Protein Interaction Analysis

    ProteOn XPR36 Protein Interaction Array System 310

    Instrument 310

    Software 312

    Regulatory Tools 314

    Sensor Chips 315

    Kits, Reagents, and Consumables 317

  • 310 | Protein Interaction Analysis

    ProteOn XPR36 Protein Interaction Array System

    Instrument

    www.bio-rad.com/proteininteraction/

    www.bio-rad.com

    The ProteOn XPR36 protein interaction array system is an SPR optical biosensor that provides real-time data on the affinity, specificity, and interaction kinetics of protein interactions. Using proprietary XPR technology, a unique approach to multiplexing, this system generates a 6 x 6 interaction array for the simultaneous analysis of up to six ligands with up to six analytes. The ProteOn XPR36 system increases the throughput, flexibility, and versatility of experiment design, enabling the completion of more experiments in less time:

    Analyze up to 36 different protein interactions in a single run, on a single chip

    Perform a complete kinetic analysis in a single run

    Measure a variety of experimental conditions simultaneously in parallel

    Screen multiple panels of analytes

    The ProteOn XPR36 system includes all of the components required for interaction analysis: instrumentation, software, sensor chips, buffer and reagent kits, and protocol

    development kits. User-friendly ProteOn Manager software uses a flexible, guided approach to coordinate instrument control, experiment setup, and data analysis.

    Key Features and Benefits Multiplex analysis using 6 x 6 array design

    Real-time data acquisition

    Analysis of interaction kinetics, binding affinity, and analyte concentration

    No radiochemical or fluorescent labels needed

    Unique referencing options such as interspot and real-time double referencing

    ApplicationsAntibody characterization and developmentDrug developmentProtein interface analysisProtein complex and cascade analysis

    For more information, request bulletin 5434A.

    The ProteOn XPR36 instrument incorporates the microfluidics, optical detection, and temperature control systems that are required for interaction analysis. It integrates a high-efficiency crisscross microfluidics system with a highly sensitive optical system to generate interaction array data on up to six ligands with panels of up to six analytes. The ProteOn XPR36 instrument features:

    Advanced optics and interspot referencing

    Innovative microfluidics design

    Flexible sample configuration (tubes or microplates)

    A temperature-controlled sensor surface (1540C) and cooled sample rack (235C)

    Hardware and software control of the fluidics, including 2 buffer reservoirs

    Status LEDs to monitor instrument, chip, experiment, and temperature state

    Bar code recognition of sensor chips

    ProteOn XPR36 Protein Interaction Array System

    Instrument

    ProteOn XPR36 Instrument

    See Also

    Profinia protein purification system:

    pages 101106.

    Experion automated electrophoresis

    system: pages 140148.

  • Protein Interaction Analysis | 311

    www.bio-rad.com/proteininteraction/

    ProteOn XPR36 Protein Interaction Array System

    Instrument

    www.bio-rad.com

    Flexible Sample ConfigurationThe autosampler accommodates the ProteOn sample rack and ProteOn microplates. The sample rack holds 72 ProteOn sample vials with pierceable caps. The microplate layout accommodates two 96-well ProteOn standard microplates or ProteOn deep-well microplates. The illuminated autosampler platform is also temperature controlled.

    Instrument Status LEDsA series of LEDs indicate instrument communication with ProteOn Manager software, temperature of the autosampler and sensor chip chambers, experiment status, and autosampler status.

    Bar Code RecognitionBar codes provide automatic recognition of sensor chip type, expiration date, and lot number. Bar codes also provide a usage record and direct linkage between the chip identification and its associated protocol and experiment.

    For more information, request bulletins 5390 and 5413.

    Advanced Optics and Interspot Referencing The ProteOn XPR36 protein interaction array system uses imaging technology to detect the SPR response for each spot on a sensor chip. The ProteOn XPR36 system measures a total of 78 spots: 36 spots represent the interaction data from the 6 x 6 array, and 42 interspot references can be used for reference subtraction.

    Innovative Fluidics and Parallel ProcessingThe 6 x 6 interaction array and microfluidics system provide efficient parallel processing of multiple samples. Two sets of six 0.5 ml syringe pumps (sample syringes and buffer syringes) operate in unison for parallel aspiration and injection of six samples or reagents.

    The buffer compartment holds two 2 L bottles for running buffer, and valve control between the two buffer bottles is hardware and software controlled. An in-line degasser removes bubbles from the buffer as it moves through the fluidics system.

    Generation of the 6 x 6 ligand-analyte interaction array. A, six ligands are immobilized in six parallel ligand channels (blue); B, six analyte samples are injected into six analyte channels perpendicular to the six ligand channels (yellow); C, detail of a single ligand-analyte interaction spot (green) showing the positions of the two interspot references (yellow).

    A B C

    Ordering Information

    Catalog # Description Price, US $

    ProteOn XPR36 Protein Interaction Array System176-0100 ProteOn XPR36 Protein Interaction Array System, 100240 V, includes ProteOn XPR36 instrument, Inquire

    2 licensed copies of ProteOn Manager software, controller and display, communication cable, sample rack, rack needle holder, microplate needle holder, needle set, collection tank, maintenance kit, 2 bottles of PBS/Tween running buffer, chip normalization solution, choice of 2 sensor chips, choice of one protocol development kit, 200 sample vials, 25 microplates with standard wells, 5 microplates with deep wells, 50 sheets of microplate sealing film

    ProteOn Accessories*176-4114 ProteOn Buffer Inlet Filters, 2 46.00176-6000 ProteOn Sample Rack, holds 72 sample vials 403.00176-6003 ProteOn Needles, 6 507.00176-6004 ProteOn Wash Station 259.00176-6061 ProteOn Collection Tank Tubing 74.00176-6005 ProteOn Syringe, replacement, 1 110.00176-6050 ProteOn Syringe, replacement, 6 550.00

    * For additional accessories, go to www.bio-rad.com/proteininteraction/.

  • 312 | Protein Interaction Analysis

    www.bio-rad.com/proteininteraction/

    ProteOn XPR36 Protein Interaction Array System

    Software

    www.bio-rad.com

    ProteOn Manager software is an intuitive workflow-oriented software package that coordinates instrument control, experiment setup, and data collection and analysis. The optional Quick Start guide enables rapid navigation to commonly performed tasks. Key software applications include those listed below.

    Instrument Control Control and monitoring of instrument communication, temperature, and power status

    Control of chip docking and undocking, instrument fluidics, and autosampler illumination

    Maintenance wizards that drive maintenance and cleaning protocols

    Viewing and filtering of the instrument log

    Protocol Design Predefined, application-based protocol templates to assist with experiment design

    Efficient creation of custom protocols through sample import or copying and pasting of sample panels

    Drag-and-drop protocol step editor for easy protocol creation

    Sample layout screen to display sample position in the rack or microplate, volume of each sample, and orientation of sample injection flow

    Import, export, and printing of protocols

    Easy data management via searchable database

    Data Collection and ViewingReal-time data collection and display

    Data filtering tools enable viewing of data by sample type and protocol step

    Data grouping tools organize data for display, processing, and analysis

    Interaction display tool allows interaction and sample data to be hidden or viewed and selected for analysis

    Data exports easily into tab-delimited files for use in other software programs like Scrubber and SigmaPlot

    Data Processing and Analysis Data processing functions allow fast and flexible processing of data and one-touch automated processing

    Report point analysis allows MW correction and export of data values

    Reference options include reference subtraction modes (interspot referencing or reference channel subtraction) and double-reference modes (a separate injection panel or a single channel within an injection panel)

    Analysis wizards perform kinetic, equilibrium, and concentration analyses and generate detailed, printable reports

    Analysis data is exported to files compatible with Microsoft Excel for easy reporting

    Kinetic models available are: Langmuir, Langmuir with mass transfer, bivalent analyte, heterogeneous analyte, heterogeneous ligand, two state, and Langmuir with drift. Reports include graphs of binding association/dissociation phases, residuals for each to evaluate the accuracy of data fitting, and results of kinetic constant calculations

    Equilibrium analysis report includes an equilibrium analysis graph describing the steady-state response for each analyte concentration

    Concentration analysis report includes a concentration analysis graph that shows the slope of the binding ratio vs. concentration curve for samples of known and unknown concentration

    Sensorgram data can be exported as data or as an image for presentations and reports

    For more information, request bulletin 5627.

    Software

    ProteOn Manager Software, Version 2.1

  • Protein Interaction Analysis | 313

    www.bio-rad.com/proteininteraction/

    ProteOn XPR36 Protein Interaction Array System

    Software

    www.bio-rad.com

    Easy kinetic analysis using ProteOn Manager sotware. A, fitted sensorgrams following analysis; B, data table from the kinetic analysis wizard.

    A B

    Ordering Information

    Catalog # Description Price, US $

    176-0200 ProteOn Manager Software, version 2.1, 1-user license, includes 1 HASP key 2,625.00176-0210 ProteOn Manager Software, Security Edition, 1-user license, includes 1 HASP key 19,250.00

    Streamlined protocol setup using the Protocol Editor. Custom protocols are quickly built by dragging and dropping protocol step groups or individual steps into the Protocol Steps window (left). Each group includes the individual protocol steps required to complete the desired task; for example, clicking and dragging the Immobilization group adds three steps to the protocol: an activation step, a ligand immobilization step, and a deactivation step. (These steps correspond to the addition of EDAC/sulfo-NHS, IL-2 antibody, and ethanolamine HCl, respectively, in the above experiment analyzing the interaction between the cytokine IL-2 and an IL-2 antibody.) The Step Details window (right) shows details and flow orientation on the array for each step.

  • 314 | Protein Interaction Analysis

    ProteOn XPR36 Protein Interaction Array System

    Regulatory Tools

    www.bio-rad.com/proteininteraction/

    www.bio-rad.com

    Ordering Information

    Catalog # Description Price, US $

    176-4225 ProteOn XPR36 Regulatory Tools Package, includes ProteOn Manager software, Security Edition, 21,500.00 1-user license, 1 HASP key, ProteOn XPR36 IQ/OQ kit

    176-0210 ProteOn Manager Software, Security Edition, 1-user license, includes 1 HASP key 19,250.00 176-4200 ProteOn XPR36 IQ/OQ Kit, includes ProteOn XPR36 IQ/OQ software, ProteOn Manager software, 4,000.00

    ProteOn operation qualification (OQ) kit 176-4220 ProteOn Operation Qualification Kit, includes ProteOn OQ Kit 1, ProteOn OQ Kit 2, ProteOn GLC 680.00

    sensor chip

    Security software and installation qualification/operation qualification (IQ/OQ) kits are available for use with the ProteOn XPR36 system. These regulatory tools can be purchased individually or as a complete package.

    ProteOn Manager Software, Security EditionProteOn Manager software is now available with controls to help achieve U.S. FDA 21 CFR Part 11 compliance. Included in the many features of this Security Edition release are:

    Audit trailsElectronic signaturesData validationUser log-ins and permissionsClosed-system security

    ProteOn XPR36 Installation Qualification/Operation Qualification (IQ/OQ) KitThe ProteOn XPR36 IQ/OQ kit has been designed to test critical system functions to ensure reliability and consistency of performance. Key features include:

    Wizard-driven software

    Printable electronic reports for document controls

    Electronic log of IQ/OQ and test results

    Ready-to-use reagents and sensor chip for testing system performance

    Unattended operation

    For more information, request bulletins 5819 and 5627.

    Regulatory Tools

    ProteOn XPR36 System Regulatory Tools Package

  • Protein Interaction Analysis | 315

    www.bio-rad.com/proteininteraction/

    ProteOn XPR36 Protein Interaction Array System

    Sensor Chips

    www.bio-rad.com

    ProteOn sensor chips combine advanced surface chemistries with state-of-the-art microfluidics. They have been thoroughly tested for a wide range of protein-protein, protein-peptide, proteinsmall molecule, and protein-DNA interactions. Each sensor chip includes a unique bar code for identification and a usage record. ProteOn sensor chips offer outstanding kinetic response characteristics, efficient binding capacities, sufficient sensitivity to detect low molecular weight analytes (>200 Da), uniform spot-to-spot response, minimal drift, and long-term storage stability.

    All ProteOn sensor chips are:

    Fully compatible with the ProteOn XPR36 protein interaction array system

    Enclosed in a cartridge for easy storage and use

    Designed for kinetic studies of biomolecular interactions

    Easily activated for efficient immobilization and high ligand activity

    Bar-coded for automatic chip identification and a usage record

    ProteOn GLC Sensor ChipDesigned for general amine coupling, this chip has a compact polymer layer with a binding capacity of approximately one protein monolayer. The GLC sensor chip is suitable for various research applications, including protein-protein interaction analysis.

    ProteOn GLM Sensor Chip The GLM sensor chip is intended for general amine coupling and features an extended polymer matrix with intermediate binding capacity for high analyte response. This chip is suitable for many applications, including proteinsmall molecule and protein-protein interaction analyses.

    ProteOn GLH Sensor ChipThe GLH sensor chip is for general amine coupling. This chip consists of a highly extended, mixed polymer layer for maximum binding capacity. The chip is optimal for proteinsmall molecule interactions and suitable for protein-protein interactions where highest sensitivity is of primary concern.

    ProteOn NLC Sensor Chip The NLC sensor chip features NeutrAvidin protein immobilized to a GLC polymer layer for binding of biotinylated molecules. The binding capacity is approximately one protein monolayer. The NLC sensor chip is suitable for many applications, including DNA-protein and protein-protein interaction analyses.

    For more information, request bulletin 5404.

    Sensor Chips

    ProteOn Sensor Chips

  • 316 | Protein Interaction Analysis

    ProteOn XPR36 Protein Interaction Array System

    Sensor Chips

    www.bio-rad.com/proteininteraction/

    www.bio-rad.com

    Ordering Information

    Catalog # Description Price, US $

    176-5011 ProteOn GLC Sensor Chip, for general amine coupling, compact polymer layer with binding capacity of 199.00 approximately one protein monolayer

    176-5012 ProteOn GLM Sensor Chip, for general amine coupling, polymer matrix layer with intermediate 220.00 binding capacity

    176-5013 ProteOn GLH Sensor Chip, for general amine coupling, polymer matrix layer with highest 246.00 binding capacity

    176-5021 ProteOn NLC Sensor Chip, for binding of biotinylated molecules, contains NeutrAvidin 246.00 immobilized to GLC layer

    ProteOn GLC sensor chip. For general amine coupling: compact polymer layer with binding capacity of approximately one protein monolayer.

    ProteOn GLM sensor chip. For general amine coupling: extended polymer matrix with intermediate binding capacity for high response.

    ProteOn NLC sensor chip. For binding of biotinylated molecules: NeutrAvidin immobilized to GLC layer.

    Prism

    Incident light Detector

    NeutrAvidin

    Analyte

    Analyte

    Prism

    Incident light Detector

    COOH

    Prism

    Analyte

    COOH

    Incident light Detector

    ProteOn GLH sensor chip. For general amine coupling: extended polymer layer for maximum binding capacity and highest sensitivity.

    Analyte

    Prism

    Incident light Detector

    COOH

    Prism

  • Protein Interaction Analysis | 317

    ProteOn XPR36 Protein Interaction Array System

    Kits, Reagents, and Consumables

    www.bio-rad.com/proteininteraction/

    www.bio-rad.com

    Ordering Information

    Catalog # Description Price, US $

    176-1010 ProteOn One-Shot Kinetics Kit, includes ProteOn IL-2/IL-2 antibody pair, GLC sensor chip, amine coupling 611.00 kit, 50 ml sodium acetate buffer, pH 4.5

    176-1020 ProteOn Multiple Protein Interaction Kit, includes ProteOn TEM1/BLIP protein set, GLC sensor chip, 1,218.00 amine coupling kit, 50 ml sodium acetate buffer, pH 4.0

    176-1030 ProteOn ProteinSmall Molecule Kit, includes ProteOn carbonic anhydrase II/CBS pair, GLM sensor chip, 605.00 amine coupling kit, 50 ml sodium acetate buffer, pH 5.0

    ProteOn protocol development kits provide the reagents and sensor chips needed to perform and analyze data from a complete experiment using the ProteOn XPR36 protein interaction array system. New users will gain familiarity with instrument setup and operation, experiment design, and data analysis. Experienced users will find the kits valuable for system benchmarking and protocol development. Each protocol development kit includes an amine coupling kit.

    ProteOn One-shot Kinetics Kit The interaction between the cytokine IL-2 and an IL-2 antibody demonstrates a detailed kinetic analysis in a single injection cycle (One-shot Kinetics). The kit also demonstrates a useful method for controlling ligand immobilization levels during protocol development and optimization.

    The ProteOn One-shot Kinetics kit includes a ProteOn IL-2/IL-2 antibody pair, with sufficient materials to immobilize IL-2 antibody in up to six channels and to analyze a complete concentration series of IL-2 across each channel.

    ProteOn Multiple Protein Interaction KitThe interaction between five mutant TEM1 b-lactamase proteins and wild-type b-lactamase inhibitor protein (BLIP) demonstrates the power of the ProteOn XPR36 system to produce a detailed kinetic analysis of multiple simultaneous interactions and to map protein interfaces.

    The ProteOn multiple protein interaction kit includes a ProteOn TEM1/BLIP protein set, with sufficient materials to immobilize five TEM1 mutant proteins in five channels and to perform a detailed kinetic analysis of the interaction of each of the five mutant proteins with BLIP.

    ProteOn ProteinSmall Molecule Kit The interaction between the carbonic anhydrase II protein and the small molecule 4-carboxy benzene sulfonamide (4-CBS) demonstrates the capability of the ProteOn XPR36 system to detect low molecular weight analytes. The kit also provides a benchmark for optimal system performance.

    The ProteOn proteinsmall molecule kit includes ProteOn carbonic anhydrase II/CBS, with sufficient materials to immobilize carbonic anhydrase II in up to six channels and analyze a complete concentration series of CBS.

    For more information, request bulletin 5410.

    Kits, Reagents, and Consumables

    ProteOn One-shot Kinetics Kit

    ProteOn Multiple Protein Interaction Kit

    ProteOn ProteinSmall Molecule Kit

    ProteOn Protocol Development Kits

  • 318 | Protein Interaction Analysis

    www.bio-rad.com/proteininteraction/

    ProteOn XPR36 Protein Interaction Array System

    Kits, Reagents, and Consumables

    www.bio-rad.com

    ProteOn Running Buffers ProteOn running buffers (PBS, PBS/Tween, and PBS/Tween/EDTA) are prefiltered and supplied in 2 L bottles sufficient for approximately 2 weeks of daily operation.

    ProteOn Chip Normalization Solution ProteOn chip normalization solution is a 50% glycerol solution used for normalization of ProteOn sensor chip surfaces. It is provided in a 100 ml bottle sufficient for 6 months of daily use.

    ProteOn Maintenance ChipsA maintenance (MNT) chip and a cleaning (CLN) chip are available individually or as part of the ProteOn maintenance kit.

    ProteOn Amine Coupling KitThe ProteOn amine coupling kit provides the reagents required for coupling ligands that have amine groups (for example, proteins and nucleic acids) to surface carboxyl groups of ProteOn GLC, GLM, and GLH sensor chips.

    The innovative surface chemistry of ProteOn sensor chips, combined with the ProteOn amine coupling reagents, minimizes electrostatic and nonspecific binding effects and optimizes ligand activities and coupling capacities. An ethanolamine hydrochloride solution is included (also available separately) for deactivation of the residual active sites on the sensor chip following activation.

    Sufficient reagents are provided for 60 moderate activations or up to 600 light activations.

    ProteOn Immobilization Buffer Kit ProteOn immobilization buffers (four acetate buffers ranging from pH 4.0 to 5.5) are designed to dilute protein samples for coupling to ProteOn sensor chips. The entire range of buffers may be used to determine the optimal pH for immobilization. Each buffer is sufficient for 100 ligand immobilizations. These buffers are also sold individually.

    ProteOn Regeneration Kit and BuffersProteOn regeneration buffers are ideal for a wide variety of regeneration conditions and are available as a complete kit of nine solutions or individually. They include glycine buffers, SDS, sodium hydroxide, hydrochloric acid, phosphoric acid, and sodium chloride.

    ProteOn Maintenance KitThe ProteOn maintenance kit contains solutions and chips for post-experiment and weekly maintenance and cleaning of the ProteOn XPR36 protein interaction array system. Each kit includes enough supplies for 6 months of routine maintenance when following the ProteOn Manager software maintenance and cleaning protocol wizards.

    ProteOn Kits and Reagents

    ProteOn Kits and Reagents

  • Protein Interaction Analysis | 319

    www.bio-rad.com/proteininteraction/

    ProteOn XPR36 Protein Interaction Array System

    Kits, Reagents, and Consumables

    www.bio-rad.com

    Ordering Information

    Catalog # Description Price, US $

    ProteOn Amine Coupling Kit and Neutralization Reagent176-2410 ProteOn Amine Coupling Kit, includes EDAC (EDC), sulfo-NHS, ethanolamine HCl 324.00176-2450 ProteOn Ethanolamine HCl, 1 M, 40 ml 61.00

    ProteOn Immobilization Buffer Kit and Components176-2110 ProteOn Immobilization Buffer Kit, includes one of each sodium acetate buffer (pH 4.0, 4.5, 5.0, 5.5) 213.00176-2120 ProteOn Acetate Buffer, pH 4.0, 10 mM sodium acetate, 50 ml 61.00176-2121 ProteOn Acetate Buffer, pH 4.5, 10 mM sodium acetate, 50 ml 61.00176-2122 ProteOn Acetate Buffer, pH 5.0, 10 mM sodium acetate, 50 ml 61.00176-2123 ProteOn Acetate Buffer, pH 5.5, 10 mM sodium acetate, 50 ml 61.00

    ProteOn Regeneration Kit and Components176-2210 ProteOn Regeneration Kit, includes one of each glycine buffer (pH 1.5, 2.0, 2.5, 3.0), sodium hydroxide 544.00

    solution, SDS solution, hydrochloric acid solution, phosphoric acid solution, sodium chloride solution, 50 ml each

    176-2220 ProteOn Glycine Buffer, pH 1.5, 10 mM glycine HCI, 50 ml 61.00176-2221 ProteOn Glycine Buffer, pH 2.0, 10 mM glycine HCI, 50 ml 61.00176-2222 ProteOn Glycine Buffer, pH 2.5, 10 mM glycine HCI, 50 ml 61.00176-2223 ProteOn Glycine Buffer, pH 3.0, 10 mM glycine HCI, 50 ml 61.00176-2230 ProteOn Sodium Hydroxide Solution, 50 mM, 50 ml 61.00176-2240 ProteOn SDS Solution, 0.5%, 50 ml 61.00176-2250 ProteOn Hydrochloric Acid Solution, 100 mM, 50 ml 61.00176-2260 ProteOn Phosphoric Acid Solution, 0.85%, 50 ml 61.00176-2270 ProteOn Sodium Chloride Solution, 1 M, 50 ml 61.00

    ProteOn Maintenance Kit and Components176-4100 ProteOn Maintenance Kit, includes maintenance chip, 2 cleaning chips, 2 maintenance solutions 520.00 (2 L 0.5% SDS, 2 L 50 mM glycine HCl, pH 9.5)176-4111 ProteOn Maintenance Solution 1, 0.5%, SDS, 2 L 72.00176-4112 ProteOn Maintenance Solution 2, 50 mM glycine hydrochloride, pH 9.5, 2 L 72.00176-5100 ProteOn MNT Maintenance Chip, for use in instrument maintenance protocol 204.00176-5110 ProteOn CLN Cleaning Chip, for use in microfluidics network cleaning protocol 170.00

    ProteOn Running Buffers, Buffer Bottle, and Chip Normalization Solution176-2710 ProteOn PBS, phosphate buffered saline, pH 7.4, 2 L 76.00176-2720 ProteOn PBS/Tween, phosphate buffered saline, pH 7.4, 0.005% Tween 20, 2 L 76.00176-2730 ProteOn PBS/Tween/EDTA, phosphate buffered saline, pH 7.4, 0.005% Tween 20, 3 mM EDTA, 2 L 86.00176-2700 ProteOn Running Buffer Bottle, 2 L capacity 36.00176-2810 ProteOn Chip Normalization Solution, 50% glycerol, 100 ml 61.00

  • 320 | Protein Interaction Analysis

    www.bio-rad.com/proteininteraction/

    ProteOn XPR36 Protein Interaction Array System

    Kits, Reagents, and Consumables

    www.bio-rad.com

    Ordering Information

    Catalog # Description Price, US $

    176-6010 ProteOn Sample Vials, 1.5 ml, with pierceable caps, 100 28.00176-6020 ProteOn Standard Microplates, 96 wells, 25 176.00176-6023 ProteOn Deep-Well Microplates, 96 wells, 5 75.00176-6040 ProteOn Microplate Sealing Film, 50 sheets 126.00

    ProteOn Sample Vials ProteOn sample vials are compatible with the ProteOn sample rack. Each 1.5 ml vial includes a pierceable cap to prevent evaporation.

    ProteOn Standard Microplates ProteOn standard microplates are compatible with the ProteOn autosampler platform. Each microplate is a standard 96-well array, and each well holds 350 l.

    ProteOn Deep-Well MicroplatesProteOn deep-well microplates are compatible with the ProteOn autosampler platform. Each microplate is a standard 96-well array, and each well holds 2.0 ml.

    ProteOn Microplate Sealing Film ProteOn microplate sealing film is specifically designed for use with the fluidic components of the ProteOn instrument. It is required for covering ProteOn standard and deep-well microplates to prevent evaporation while running a protocol or during storage. The sealing film is easily applied to each microplate and is pierceable.

    ProteOn Sample Vials

    ProteOn Standard Microplates

    ProteOn Deep-Well Microplates

    ProteOn Microplate Sealing Film

    ProteOn Vials, Microplates, and Sealing Film