Designed and built for the most demanding and critical commercial/industrial applications
Application Expertise and Support Our sales force has been selected with their knowledge of electrical power systems as the first requirement. In combination with engineering staff support, this team will work with you to understand the project and specific needs to develop not just a solution, but the right solution.
Engineering Excellence Trained staff utilizing state of the art engineering and modeling software provide precision design, documentation and performance calculations prior to commencing manufacturing.
World Class ManufacturingDemand-driven manufacturing system provides flexibility in scheduling to meet aggressive project deadlines.LEAN Enterprise and Continuous Improvement culture insures that each unit is built to specifications and meets quality testing.
From harsh environments to critical power to demanding application requirements, we’re committed to provide you a dedicated solution built to last.
OVAL STACKED CORE DATA Drawing No 04-UC3045P13800CCQ1CALCULATION REPORT Design Rev. 0
By:Transformer : 45 [kVA] 3 Phases Date:
S.O.# P/N: 157-0000-021Customer: 0
Rated Power 45 [kVA]LV Line Voltage 208 [V]# of Phases 3# of Legs 3LV Connection WyeFrequency 60 [Hz] [in] [in] [Lb] [Lb] [Lb] [in] [in] [in]Turns 23 W1 4 B1 2.968 56 56.5 125.6 134.9 4.000Core W2 3 B2 2 x 1.272 2x 24 37.3 80.7 87.6 3.933Core Length A 26.5 [in] W3 3 B3 3.933Overall Core Length A1 27.50 [in] W4 B4Core Height B 24 [in] W5 B5Overall Core Height B1 25.000 [in] W6 B6Window Width C 7.25 [in] W7 B7Leg Width D 4 [in] W8 B8Leg Centers E 11.25 [in] W9 B9Window Height H 16 [in] W10 B10
W11 B11W12 B12W13 B13W14 B14W15 B15W16 B16
# of holes 7 W17 B17 41027Hole Diameter X 10 [mm] W18 B18# Sheets/ book (Nsb) 5 Wins 11.50 Tins 0.0625 4.015 Tie Plate Insul.Design Core CSA 18.561 [sq in] Wtp 2 Ttp 0.25 5 3.696 Tie PlateTotal Effective core (CSAef) 18.724 [sq in]Total Core Stack 5.512 [in] Total [Lb]/Limb 94 206 223
4.000 [in] MAIN STEP PACKING -No Packing RequiredPb 0.0625 in x N/A in
Material M4 Core Flux Density 1.62 [T] 1.70 [T] 1.78 [T] 2.03 [T] Pb 0.0625 in x N/A in Thickness 0.01060 [in] Core Losses 316 [W] 376 [W] 462 [W] 462 [W]Core Type Core Sound Level 53.3 [dBA] 56.6 [dBA] 59.8 [dBA] 69.5 [dBA]Core Stacking Factor (Sf) 0.96 Exciting current 1.14 [%] 0.66 [%] 3.93 [%] 95.96 [%]Cooling Duct Space 0.000 [in] Temperature Rise [°C] @110% VoltageCore Net Weight 523 [Lb] Inner Hot Spot RiseFilling Factor 0.766 Surface Rise
Core cost @ 2.2025[$/Lb] 1,151 [$][mm] [in] [mm] [in] NLL Eval Cost @ 8[$/W] 2,528 [$]
Cyl ID 107.95 4.250 Coil Elec. Length 0 0.000Winding ID 0 0.000 Coil Mech Length Corners [ %] 18%
Rad. Mech. Clearance 0 0.000 Mech Clearance/sideRad. Elec. Clearance 0 0.000 Elec Clearance/side 203.2 8.294 Average Lump Specific Losses 0.605 [W/Lb]
BIL [kV] 0Global DF 1.046
NOTES
Application Rev.36 last revised by VT on 3-Feb-16
Vertical Hole Spacing G 12.5 [in]
Horizontal hole spacing G1 11.25
105 % Voltage
This core contains no cooling ducts
110% Voltage
[in]
Leg Width (if different from D) I 4
Net Weight/ Step/Yoke
StepDiameterCORE STEPS [in]
# Books/
step
Cen LegNet
Weight/ Step
Dowel Diameter
Dowel Notch
125% VoltageOptional
100% Voltage
19.504
VT2/9/2017
The core construction is Fully mitered, Step lapped.V, in 3 steps and five (5) sheets per book. Sheets offset is 6.35 [mm](-12.7, -6.35, 0, 6.35, 12.7 [mm]). Specific losses accepted at 1.7[T] and 60 [Hz] are 0.685 [W/Lb]. Estimated losses at 1.62 [T] (100% Voltage) are 316 [W]. Estimated losses at 1.78 [T] (110 % Voltage) are 462 [W].
Chamfer the tie plate outside edges by 0.125[in]After the core is fully assembled with the core insulation, tie plates and clamps, the supplier must test the Insulation Resistance at 1000 [ V DC] for one minute. The reading should be minimum 10 [M Ohm]. A copy of the test sheet must be sent to PTI for approval prior to shipping.
AXIALRADIALINNER COIL DETAILS
50.350.1
Out LegNet
Weight/ Step
[in]
Fully mitered, Step lapped.V
Core Main Step Width (W1) [in]
UC3045P13800CCQ1
‐2.5
‐2
‐1.5
‐1
‐0.5
0
0.5
1
1.5
2
2.5
‐4 ‐3 ‐2 ‐1 0 1 2 3 4
Wi [in]
Bi [in]
True Scale Core SectionCircle
Core
Cooling duct
Insulation Tie plate
Tie plate
Cylinder ID
Industry Leader Pioneer’s 70,000 square foot manufacturing facility in Reynosa, Mexico contains state-of-the-art manufacturing equipment, certified testing labs and a scalable production layout to adapt to changing market conditions.
Miter Core ConstructionAll cores are designed and built using a step lap miter core construction. This design minimizes losses for maximum efficiency, quiet operation and superior performance.
Vacuum Pressure Impregnation All transformers go through a vacuum pressure impregnation (VPI) process to ensure complete absorption of the polyester resin and the elimination of all air pockets for complete protection of the conductor, superior strength, design integrity and performance.
Custom TerminationsPioneer offers nine standard termination configurations. We can also design and build custom configurations for your specific application assuring the proper installation with other equipment.
■ 150 kVA to 10 mVA■ Up to 34.5KV Class; 150KV
BIL Rating■ Barrel or Disc Wound Coils■ UL, UR, CSA
■ Open Core & Coil or with NEMA 1, 2 or 3R Enclosure
■ Applicationspecificoptions■ Certifiedtestinglab■ ABScertification
Providing a broad range of product capabilities designed and manufactured for superior performance and durability.
Ratings, capabilities and certifications
LIT980-0817
PIONEER Medium Voltage Transformers
800-892-3755 Pioneer MVMagnetics.com
Pioneer companies have been designing and building transformers and reactors for over 100 years. Our companies were built on a promise to meet if not exceed the highest industry standards for quality, reliability and durability. Today, Pioneer continues this commitment and culture of excellence, making us a provider of choice for commercial, industrial and OEM markets.
We produce over 100,000 transformers every year. With this high level of production comes buying power, a broad knowledge base and rapid work flow to meet the needs of our customers’ magnetic products in a wide variety of applications and industries. ■ Purchasing power of raw materials ■ Large engineering staff for quick design turnaround ■ Best delivery of custom options
Pioneer Transformers: The Transformer Authority