Post on 07-Aug-2020
P-VIP Replacement Lamps,Subject to alteration Page: 1
DO DIS
P-VIP Replacement Lamps
P-VIP Replacement Lamps,Subject to alteration Page: 2
DO DIS
P-VIP® and VIP® after sales lamps
General description
New after sales lamps
Existing after sales lamps
Instruction for use
P-VIP Replacement Lamps Agenda
P-VIP Replacement Lamps,Subject to alteration Page: 3
DO DIS
P-VIP MD TV Replacement Lamps
482 47E01HM4008321 126 64150TVP-VIP 120-132/1.0 E22ha
542 959 002G4008321 24428450TVP-VIP 132-150/1.0 E23ha
542 94D 002G4008321 24426050TVP-VIP 132-150/1.0 E22ha
535 05B 002G4008321 221 56850TVP-VIP 100-120/1.0 E23ha
535 073 002G4008321 221 58250TVP-VIP 100-120/1.0 E22ha
541 559 01874008321 24361450TVP-VIP 100-120/1.3 P23a
542 930 002G4008321 90132350TVP-VIP 100-120/1.3 E23a
518 63B 002G4008321 194 94750TVP-VIP 120-132/1.0 P22ha
518 62F 002G4008321 194 92350TVP-VIP 100-120/1.0 P22ha
518 59A 002G4008321 194 90950TVP-VIP 100-120/1.3 E23ha
ICEAN 10 (1pcs)
Box size, pcs.Cat.Lamp type
P-VIP Replacement Lamps,Subject to alteration Page: 4
DO DIS
P-VIP FP Replacement Lamps
518 71D 002G4008321 195 10460FPP-VIP 200/1.0 E19a
544 77A 002G4008321 24223560FPP-VIP 200/1.0 E17.5a
A54256C002G4008321 257 29150FPP-VIP 250/1.3 E21.8a
518 688 002G4008321 195 04350FPP-VIP 200/1.0 P21.5a
518 700 002G4008321 195 08150FPP-VIP 180/1.0 E20a
518 67C 002G4008321 195 02950FPVIP R 150/P22a
518 647 002G4008321 194 96150FPP-VIP 150/1.3 E21.5a
518 661 002G4008321 195 00550FPVIP R 150/P16a
518 653 002G4008321 194 98550FPVIP R 120/P16a
518 694 002G4008321 195 06760FPVIP R 120/P12a
538 118 002G4008321 22866650FPP-VIP 150/1.0 P21.5a
ICEAN 10 (1pcs)
Box size, pcs.Cat.Lamp type
P-VIP Replacement Lamps,Subject to alteration Page: 5
DO DIS
P-VIP® and VIP® after sales lamps
General description
New after sales lamps
Existing after sales lamps
Instruction for use
P-VIP Replacement Lamps Agenda
P-VIP Replacement Lamps,Subject to alteration Page: 6
DO DIS
Supreme efficiency P-VIP® and VIP® lamps
Highest quality meeting the strict quality demands of
the CE and IT industries
From leading player in the market
P-VIP Replacement Lamps Advantages
P-VIP Replacement Lamps,Subject to alteration Page: 7
DO DIS
Technology Discharge lamps with Mercury-halogen gas
Lamp power 100 – 250 W AC
Lumen yield > 60 lm / W
Pressure cold lamp: 100 mbar
hot lamp: up to 250 bar
Burner temperature operating: up to 1200 °C
typical cool down < 5 min.
Pre-materials
Burner Glass: ultra pure quartz glass
Electrodes: Tungsten
Reflector Glass, coated with dichroic mirror
a) Valid for P-VIP and VIP R lamps
P-VIP® Technical Aspects
P-VIP Replacement Lamps,Subject to alteration Page: 8
DO DIS
P-VIP 150/1.3 E21.5ha
‘ProfessionalVideo Projection’ –high performance discharge lamp
Lamp power
Electrode gapReflector shapeElliptical or P arabolic
Reflector size
Extra Infoh: 15 kV ignition
Aftermarket
P-VIP® Lamp Naming
P-VIP Replacement Lamps,Subject to alteration Page: 9
DO DIS
VIP R 150 / P16a
Video Projection’ –high performance discharge lamp
Lamp power Reflector shapeand size
After market
Reflector
P-VIP® Lamp Naming
P-VIP Replacement Lamps,Subject to alteration Page: 10
DO DIS
P-VIP® and VIP® after sales lamps
General description
New after sales lamps
Existing after sales lamps
Instruction for use
P-VIP Replacement Lamps Agenda
P-VIP Replacement Lamps,Subject to alteration Page: 11
DO DIS
Lamp P-VIP 120-132/1.0 E22ha
� Category MD TV� Reflector E22 – elliptic� Arc gap 1.0 mm� Power range 120 – 132 W� Ignition 15 – 18 kV� Light output typ.a 5,900 lm @ 132 W� Average Life timeb > 6,000 h @ 132 W� Environmental Complies RoHS
a) observed in working distance through ∅ 6 mm aperture
b) when operated on OSRAM lamp driver PT VIP 01 RP
P-VIP Replacement Lamps,Subject to alteration Page: 12
DO DIS
Lamp P-VIP 120-132/1.0 E22ha
04:00 o‘clocklocation contact 2a
central at baselocation contact 1a
tooled air gapsair inletsborosilicateReflector glassyesfront glass34.0 mmworking distance
Lamp designE22 – ellipticContour
< 85.0
F2
34.0
70
Top
65
A
A
A = reference edgeDimensions in mm
View from Rear
Glass air guidesnot to scale
30°
P-VIP Replacement Lamps,Subject to alteration Page: 13
DO DIS
Lamp P-VIP 100-120/1.3 E23a
� Category MD TV� Reflector E23 – elliptic� Arc gap 1.3 mm� Power range 100 – 120 W� Ignition 5 – 7 kV� Light output typ.a 5,200 lm @ 120 W� Average Life timeb > 6,000 h @ 120 W� Environmental Complies RoHS
a) observed in working distance through ∅ 6 mm aperture
b) when operated on OSRAM lamp driver PT VIP 2AC/380 O1
P-VIP Replacement Lamps,Subject to alteration Page: 14
DO DIS
Lamp P-VIP 100-120/1.3 E23a
dimensions in mm
03:00 o‘clocklocation contact 2a
a) viewed from front
central at baselocation contact 1a
no, lamp closedair inletsborosilicateReflector glassyesfront glass52.0 mmworking distance
Lamp designE23 – ellipticContour
< 88.0
front view
95.0 F2
52.0
top
P-VIP Replacement Lamps,Subject to alteration Page: 15
DO DIS
Lamp P-VIP 132-150/1.0 E22ha
� Category MD TV� Reflector E22 – elliptic� Arc gap 1.0 mm� Power range 132 – 150 W� Ignition 15 – 18 kV� Light output typ.a 6,500 lm @ 150 W� Average Life timeb 6,000 h @ 150 W� Environmental Complies RoHS
a) observed in working distance through ∅ 6 mm aperture
b) when operated on OSRAM lamp driver PT VIP 01 RP
P-VIP Replacement Lamps,Subject to alteration Page: 16
DO DIS
04:00 o‘clocklocation contact 2a
central at baselocation contact 1a
tooled air gapsair inletsborosilicateReflector glassyesfront glass34.0 mmworking distance
Lamp designE22 – ellipticContour
< 85.0
F2
34.0
70
Top
65
A
A
A = reference edgeDimensions in mm
View from Rear
Glass air guidesnot to scale
30°
Lamp P-VIP 132-150/1.0 E22ha
P-VIP Replacement Lamps,Subject to alteration Page: 17
DO DIS
Lamp P-VIP 132-150/1.0 E23ha
� Category MD TV� Reflector E23 – elliptic� Arc gap 1.0 mm� Power range 132 – 150 W� Ignition 15 – 18 kV� Light output typ.a 6,500 lm @ 150 W� Average Life timeb 6,000 h @ 150 W� Environmental Complies RoHS
a) observed in working distance through ∅ 6 mm aperture
b) when operated on OSRAM lamp driver PT VIP O1RP
P-VIP Replacement Lamps,Subject to alteration Page: 18
DO DIS
Lamp P-VIP 100-120/1.0 E23ha
dimensions in mm
03:00 o‘clocklocation contact 2a
a) viewed from front
central at baselocation contact 1a
no, lamp closedair inletsborosilicateReflector glassyesfront glass52.0 mmworking distance
Lamp designE23 – ellipticContour
< 88.0
front view
95.0 F2
52.0
top
P-VIP Replacement Lamps,Subject to alteration Page: 19
DO DIS
Lamp P-VIP 100-120/1.3 P23a
� Category MD TV� Reflector P23 – parabolic� Arc gap 1.3 mm� Power range 100 – 120 W� Ignition 15 – 18 kV� Light output typ.a 4,400 lm @ 120 W� Average Life timeb 6,000 h @ 120 W� Environmental Complies RoHS
a) observed in 900 mm distance through ∅ 95 mm aperture
b) when operated on OSRAM lamp driver PT VIP 2AC/380 O1
P-VIP Replacement Lamps,Subject to alteration Page: 20
DO DIS
Lamp P-VIP 100-120/1.3 P23a
dimensions in mm
04:30 o‘clocklocation contact 2a
a) viewed from front
central at baselocation contact 1a
noair inletsborosilicateReflector glassyesfront glassinfiniteworking distance
Lamp designP23 – parabolicContour
< 82.0
top
front view
Max
. 96.
0
< 92.0
P-VIP Replacement Lamps,Subject to alteration Page: 21
DO DIS
Lamp P-VIP 200/1.0 E17.5a
� Category FP� Reflector E17.5 – elliptic� Arc gap 1.0 mm� Rated power 200 W� Ignition 16 kV� Light output typ.a 6,300 lm @ 200 W� Average Life timeb 2,000 h @ 200 W� Environmental Complies RoHS
a) observed in working distance through 5.0 x 3.8 mm2 rectangularaperture
b) when operated on OSRAM lamp driver PT VIP 3 AC/380 O3
P-VIP Replacement Lamps,Subject to alteration Page: 22
DO DIS
dimensions in mm
10:30 o‘clocklocation contact 2a
a) viewed from front
Side at baselocation contact 1a
noair inletsaborosilicateReflector glassnofront glass39.15 mmworking distance
Lamp designE17.5 – ellipticContour
< 52,0
F2
48.0
43.0
front view
top
Lamp P-VIP 200/1.0 E17.5a
39,15
P-VIP Replacement Lamps,Subject to alteration Page: 23
DO DIS
Lamp P-VIP 250/1.3 E21.8a
� Category FP� Reflector E21.8 – elliptical� Arc gap 1.3 mm� Rated power 250 W� Ignition 5 kV� Light output typ.a 8.600 lm @ 250 W� Average Life timeb > 2,000 h @ 250 W� Environmental Complies RoHS
a) observed in working distance through 5.0 x 3.8 mm2 rectangular aperture
b) when operated on OSRAM lamp driver PT VIP 5AC/380 O4
P-VIP Replacement Lamps,Subject to alteration Page: 24
DO DIS
Lamp P-VIP 250/1.3 E21.8a
04:00 o‘clocklocation contact 2a
central at baselocation contact 1a67 mmLamp lenght
air gapsair inletsCristalizedReflector glassyesfront glass36.0 mmworking distance
Lamp designE21.82 – ellipticalContour
61 6
P-VIP Replacement Lamps,Subject to alteration Page: 25
DO DIS
P-VIP® and VIP® after sales lamps
General description
New after sales lamps
Existing after sales lamps
Instruction for use
P-VIP Replacement Lamps Agenda
P-VIP Replacement Lamps,Subject to alteration Page: 26
DO DIS
Lamp P-VIP 100-120/1.0 E23ha
� Category MD TV� Reflector E23 – elliptic� Arc gap 1.3 mm� Power range 100 – 120 W� Ignition 15 – 18 kV� Light output typ.a 5,200 lm @ 120 W� Average Life timeb > 6,000 h @ 120 W� Environmental Complies RoHS
a) observed in working distance through ∅ 6 mm aperture
b) when operated on OSRAM lamp driver PT VIP 2AC/380 O1
P-VIP Replacement Lamps,Subject to alteration Page: 27
DO DIS
Lamp P-VIP 100-120/1.0 E23ha
dimensions in mm
03:00 o‘clocklocation contact 2a
a) viewed from front
central at baselocation contact 1a
no, lamp closedair inletsborosilicateReflector glassyesfront glass52.0 mmworking distance
Lamp designE23 – ellipticContour
< 88.0
front view
95.0 F2
52.0
top
P-VIP Replacement Lamps,Subject to alteration Page: 28
DO DIS
Lamp P-VIP 100-120/1.0 E22ha
� Category MD TV� Reflector E22 – elliptic� Arc gap 1.0 mm� Power range 100 – 120 W� Ignition 15 – 18 kV� Light output typ.a 5,200 lm @ 120 W� Average Life timeb > 6,000 h @ 120 W� Environmental Complies RoHS
a) observed in working distance through ∅ 6 mm aperture
b) when operated on OSRAM lamp driver PT VIP 01 RP
P-VIP Replacement Lamps,Subject to alteration Page: 29
DO DIS
Lamp P-VIP 100-120/1.0 E22ha
04:00 o‘clocklocation contact 2a
central at baselocation contact 1a
tooled air gapsair inletsborosilicateReflector glassyesfront glass34.0 mmworking distance
Lamp designE22 – ellipticContour
< 85.0
F2
34.0
70
Top
65
A
A
A = reference edgeDimensions in mm
View from Rear
Glass air guidesnot to scale
30°
P-VIP Replacement Lamps,Subject to alteration Page: 30
DO DIS
Lamp P-VIP 150/1.0 P21.5a
� Category FP� Reflector P21.5 – parabolic� Arc gap 1.0 mm� Power range 150 W� Ignition 5 kV� Light output typ.a 5,300 lm @ 150 W� Average Life timeb 1,500 h @ 150 W� Environmental Complies RoHS
a) observed in 900 mm distance through ∅ 95 mm aperture
b) when operated on OSRAM lamp driver PT VIP 150AC/380 O1
P-VIP Replacement Lamps,Subject to alteration Page: 31
DO DIS
Lamp P-VIP 150/1.0 P21.5a
dimensions in mm
07:30 o‘clocklocation contact 2a
a) viewed from front
04:30 o‘clocklocation contact 1a
4 x, on all four sidesair inletscrystallizedReflector glassyesfront glassinfiniteworking distance
Lamp designP21.5 – parabolicContour
< 73.056.0
52.0 front view
top
P-VIP Replacement Lamps,Subject to alteration Page: 32
DO DIS
Lamp P-VIP 100-120/1.3 E23ha
� Category MD TV� Reflector E23 – elliptic� Arc gap 1.3 mm� Power range 100 – 120 W� Ignition 15 – 18 kV� Light output typ.a 5,200 lm @ 120 W� Average Life timeb > 6,000 h @ 120 W� Environmental Complies RoHS
a) observed in working distance through ∅ 6 mm aperture
b) when operated on OSRAM lamp driver PT VIP 2AC/380 O1
P-VIP Replacement Lamps,Subject to alteration Page: 33
DO DIS
Lamp P-VIP 100-120/1.3 E23ha
dimensions in mm
03:00 o‘clocklocation contact 2a
a) viewed from front
central at baselocation contact 1a
no, lamp closedair inletsborosilicateReflector glassyesfront glass52.0 mmworking distance
Lamp designE23 – ellipticContour
< 88.0
front view
95.0 F2
52.0
top
P-VIP Replacement Lamps,Subject to alteration Page: 34
DO DIS
Lamp P-VIP 100-120/1.0 P22ha
� Category MD TV� Reflector P22 – parabolic� Arc gap 1.0 mm� Power range 100 – 120 W� Ignition 15 – 18 kV� Light output typ.a 3,800 lm @ 120 W� Average Life timeb > 6,000 h @ 120 W� Environmental Complies RoHS
a) observed in 2400 mm distance through ∅ 160 mm aperture
b) when operated on OSRAM lamp driver PT VIP 2AC/380 O1
P-VIP Replacement Lamps,Subject to alteration Page: 35
DO DIS
Lamp P-VIP 100-120/1.0 P22ha
dimensions in mm
04:30 o‘clocklocation contact 2a
a) viewed from front
central at baselocation contact 1a
no, lamp closedair inletsborosilicateReflector glassyesfront glassinfiniteworking distance
Lamp designP22 – parabolicContour
< 82.070.0
65.0 front view
top
P-VIP Replacement Lamps,Subject to alteration Page: 36
DO DIS
Lamp P-VIP 120-132/1.0 P22ha
� Category MD TV� Reflector P22 – parabolic� Arc gap 1.0 mm� Power range 120 – 132 W� Ignition 15 – 18 kV� Light output typ.a 4,500 lm @ 132 W� Average Life timeb > 6,000 h @ 132 W� Environmental Complies RoHS
a) observed in 2400 mm distance through ∅ 160 mm aperture
b) when operated on OSRAM lamp driver PT VIP O1 RP 132
P-VIP Replacement Lamps,Subject to alteration Page: 37
DO DIS
Lamp P-VIP 120-132/1.0 P22ha
dimensions in mm
04:30 o‘clocklocation contact 2a
a) viewed from front
central at baselocation contact 1a
1 x TOP, 1 x BOTTOMair inletsborosilicateReflector glassyesfront glassinfiniteworking distance
Lamp designP22 – parabolicContour
< 82.070.0
65.0 front view
top
P-VIP Replacement Lamps,Subject to alteration Page: 38
DO DIS
Lamp VIP R 120/P12a
� Category FP� Reflector E18 – elliptic� Arc gap 1.0 mm� Rated power 120 – 132 W� Ignition 5 kV� Light output typ.a 4,900 lm @ 132 W� Average Life timeb > 3,000 h @ 132 W� Environmental Complies RoHS
a) observed in working distance through 5.0 x 3.8 mm2 rectangular aperture
b) when operated on OSRAM lamp driver PT VIP 120AC/100-240 Q1
P-VIP Replacement Lamps,Subject to alteration Page: 39
DO DIS
Lamp VIP R 120/P12a
dimensions in mm
01:30 o‘clocklocation contact 2a
a) viewed from front
10:30 o‘clocklocation contact 1a
burner extends overreflector rim
air inletsborosilicateReflector glass
nofront glass26.6 mmworking distance
Lamp designE18 – ellipticContour
< 45.0
F2
26.6
< 3.5
48.0
43.7
front view
top
P-VIP Replacement Lamps,Subject to alteration Page: 40
DO DIS
Lamp VIP R 120/P16a
� Category FP� Reflector P16 – elliptic� Arc gap 1.0 mm� Rated power 120 W� Ignition 20 kV� Light output typ.a 4,400 lm @ 120 W� Average Life timeb >1,500 h @ 120 W� Environmental Complies RoHS
a) observed in working distance through 5.0 x 3.8 mm2 rectangular aperture
b) when operated on OSRAM lamp driver PT VIP 120AC/100-240 H
P-VIP Replacement Lamps,Subject to alteration Page: 41
DO DIS
Lamp VIP R 120/P16a
dimensions in mm
SMK 101CCT-92-01 maleHV plug
70/100 mm leads with plugattached to lamp
HV contacting1 x left, 1 x rightair inletsborosilicateReflector glassfront cap incl. front glassfront glass26.0 mmworking distance
Lamp designP16 – ellipticContour
< 70.0
F2
26.0
front view
top
47.8
49.7
P-VIP Replacement Lamps,Subject to alteration Page: 42
DO DIS
Lamp VIP R 150/P16a
� Category FP� Reflector P16 – elliptic� Arc gap 1.3 mm� Rated power 150 W� Ignition 20 kV� Light output typ.a 5,200 lm @ 150 W� Aaverage Life timeb >3,000 h @ 150 W� Environmental Complies RoHS
a) observed in working distance through 5.0 x 3.8 mm2 rectangular aperture
b) when operated on OSRAM lamp driver PT VIP 150AC/100-240 H2
P-VIP Replacement Lamps,Subject to alteration Page: 43
DO DIS
Lamp VIP R 150/P16a
dimensions in mm
SMK 101CCT-92-01 maleHV plug
70/100 mm leads with plugattached to lamp
HV contacting1 x left, 1 x rightair inletsborosillicateReflector glassfront cap incl. front glassfront glass26.0 mmworking distance
Lamp designP16 – ellipticContour
< 70.0
F2
26.0
front view
top
47.8
49.7
P-VIP Replacement Lamps,Subject to alteration Page: 44
DO DIS
Lamp P-VIP 150/1.3 E21.5a
� Category FP� Reflector E21.5 – elliptic� Arc gap 1.3 mm� Rated power 150 W� Ignition 16 kV� Light output typ.a 5,500 lm @ 150 W� Average Life timeb > 2,500 h @ 150 W� Environmental Complies RoHS
a) observed in working distance through 5.0 x 3.8 mm2 rectangular aperture
b) when operated on OSRAM lamp driver PT VIP 150AC/100-240 H1
P-VIP Replacement Lamps,Subject to alteration Page: 45
DO DIS
Lamp P-VIP 150/1.3 E21.5a
dimensions in mm
01:30 o‘clocklocation contact 2a
a) viewed from front
central at baselocation contact 1a
slot on left sideair inletsaborosilicateReflector glassyesfront glass17.3 mmworking distance
Lamp designE21.5 – ellipticContour
< 76.5
F2
17.356.0
52.0 front view
top
P-VIP Replacement Lamps,Subject to alteration Page: 46
DO DIS
Lamp VIP R 150/P22a
� Category FP� Reflector P22 – parabolic� Arc gap 1.3 mm� Power range 150 W� Ignition 16 kV� Light output typ.a 3800 lm @ 150 W� Average Life timeb 1000 h @ 150 W� Environmental Complies RoHS
a) observed in 900 mm distance through ∅ 95 mm aperture
b) when operated on OSRAM lamp driver PT VIP 150AC/100-240 H1
P-VIP Replacement Lamps,Subject to alteration Page: 47
DO DIS
Lamp VIP R 150/P22a
dimensions in mm
4:30 o‘clocklocation contact 2a
a) viewed from front
central at baselocation contact 1a
no, lamp closedair inletsborosilicateReflector glassyesfront glassinfiniteworking distance
Lamp designP22 – parabolicContour
< 82.070.0
65.0 front view
top
P-VIP Replacement Lamps,Subject to alteration Page: 48
DO DIS
Lamp P-VIP 180/1.0 E20a
� Category FP� Reflector E20 – elliptic� Arc gap 1.0 mm� Rated power 180 W; Dimm: 156 W� Ignition 5 kV� Light output typ.a 6,800 lm @ 180 W� Average Life timeb >3,000 h @ 180 W� Environmental Complies RoHS
a) observed in working distance through 5.0 x 3.8 mm2 rectangular aperture
b) when operated on OSRAM lamp driver PT VIP 180AC/100-240 H1
P-VIP Replacement Lamps,Subject to alteration Page: 49
DO DIS
Lamp P-VIP 180/1.0 E20a
dimensions in mm
SMK 101CCT-92-01 maleHV plug
100/100 mm leads withplug attached to lamp
HV contacting1 x left, 1 x rightair inletsborosilicateReflector glassfront cap incl. front glassfront glass26.0working distance
Lamp designE20 – ellipticContour
< 70.0
F2
26.0
front view
top
47.8
49.7
P-VIP Replacement Lamps,Subject to alteration Page: 50
DO DIS
Lamp P-VIP 200/1.0 P21.5a
� Category FP� Reflector P21.5 – parabolic� Arc gap 1.0 mm� Power range 200 W, Dimm: 160W� Ignition 5 kV� Light output typ.a 8,000 lm @ 200 W� Average Life timeb 1,500 h @ 200 W� Environmental Complies RoHS
a) observed in 900 mm distance through ∅ 95 mm aperture
b) when operated on OSRAM lamp driver PT VIP 3AC/380 O3
P-VIP Replacement Lamps,Subject to alteration Page: 51
DO DIS
Lamp P-VIP 200/1.0 P21.5a
dimensions in mm
07:30 o‘clocklocation contact 2a
a) viewed from front
04:30 o‘clocklocation contact 1a
4 x, on all four sidesair inletscrystallizedReflector glassyesfront glassinfiniteworking distance
Lamp designP21.5 – parabolicContour
< 73.056.0
52.0 front view
top
P-VIP Replacement Lamps,Subject to alteration Page: 52
DO DIS
Lamp P-VIP 200/1.0 E19a
� Category FP� Reflector E19 – elliptic� Arc gap 1.0 mm� Power range 200 W� Ignition 2.5 – 5 kV� Light output typ.a 8,200 lm @ 200 W� Average Life timeb 2,500 h @ 200 W� Environmental Complies RoHS
a) observed in working distance through 5.0 x 3.8 mm2 rectangular aperture
b) when operated on OSRAM lamp driver PT VIP O3 MID 200
P-VIP Replacement Lamps,Subject to alteration Page: 53
DO DIS
Lamp P-VIP 200/1.0 E19a
dimensions in mm
01:30 o‘clocklocation contact 2a
a) viewed from front
10:30 o‘clocklocation contact 1a
burner extends overreflector rim
air inletscrystallizedReflector glassnofront glass37.7 mmworking distance
Lamp designE19 – ellipticContour
< 42.546.0
46.0
F2
37.7
< 13.5
rear view
top
P-VIP Replacement Lamps,Subject to alteration Page: 54
DO DIS
P-VIP® and VIP® after sales lamps
General description
New after sales lamps
Existing after sales lamps
Instruction for use
P-VIP Replacement Lamps Agenda
P-VIP Replacement Lamps,Subject to alteration Page: 55
DO DIS
P-VIP Instruction for Use
For lamp replacement
� switch off power,
� disconnect mains supply,
� disconnect power cord,
allow lamp to reach room temperature.
This P-VIP lamp
operates at high pressure and at high temperature a nd may
unexpectedly shatter.
generates ultraviolet radiation which may cause ski n and
eye irritation with prolonged exposure.
must be operated only in suitably designed, enclose d fixtures which
prevent direct observation of the arc and will pre vent lamp fragments
from exiting, in the unlikely event of a lamp ruptu re.
P-VIP Replacement Lamps,Subject to alteration Page: 56
DO DIS
P-VIP Instruction for Use
Do not touch the lamp with bare hands.
If necessary, lamp can be cleaned with lint free to wel
before operation.
Protect lamp environment against high ignition puls es
Front projection max. 8 kV and rear projection max. 23 kV
Avoid direct contact of objects to reflector cover glass.
This lamp must not be operated with a broken, crack ed
or loose reflector or cover glass.
Fast on-off-cycles will reduce lamp life ( 10 min o n/off)
Operate lamp only in accordance with UL 1950 regula tions.
Avoid back-reflection of light into burner.
P-VIP Replacement Lamps,Subject to alteration Page: 57
DO DIS
P-VIP Instruction for Use
Disposal
For disposal of spent lamps, always consult federal , state, local and
provincial hazardous waste disposal rules and regul ations to ensure
proper disposal.
Caution
This lamp emits ultra violet (UV) radiation and ope rates at high pressure.
This lamp may only be used in enclosed fixtures tha t comply with
UL1572. Due to the high luminous efficacy, the UV r adiation which the
lamp emits and the high pressure within the lamp, P -VIP lamps may
only be operated within enclosed, purpose-built hou sings.