Not just a pretty picture

Post on 14-Jan-2016

39 views 7 download

Tags:

description

Not just a pretty picture. 2011. Jul. 14 Hyun wook Le e. Visualization and Representation. Which program do you want to use? At which density (contour) level are you going to present your structure? How will you show people what you see?. 105 softwares!. - PowerPoint PPT Presentation

Transcript of Not just a pretty picture

Not just a pretty picture

2011. Jul. 14

Hyunwook Lee

Visualization and Representation

• Which program do you want to use?

• At which density (contour) level are you going to present your structure?

• How will you show people what you see?

http://molvis.sdsc.edu/visres/molvisfw/titles.jsp#C

105 softwares!

Density (contour) level

• Volume is very sensitive to small changes in contour level, which in turn is sensitive to scaling and CTF correction.

• As a guide, workers typically need to contour at about 120% of the expected volume in order to obtain a surface that makes biological sense.

EV71(+Fab)

0.5 1.0 2.0

CVB3-CAR

0.5 1.0 2.0

How to show them?

• We should present the structure in a way which makes people can see what we see.

Human Rhinovirus 14 & Fab

QuickTime™ and a decompressor

are needed to see this picture.

Hansong Liu et.al (1994) JMB

Different color for chemically distinct groups Rotavirus & Fab

QuickTime™ and a decompressor

are needed to see this picture.

Prasad et al. 1990 Nature

Cut-open views T. maritima nanocompartment

http://schaechter.asmblog.org/schaechter/2011/04/beyond-the-bacterial-microcompartment.html

Radially cut surface : Simian virus 40

QuickTime™ and a decompressor

are needed to see this picture.

TS Baker. 1994 PNAS

Icosahedrally cut surface Infectious Bursal Disease Virus

B. Bottcher et al. 1997 J of Virol

QuickTime™ and a decompressor

are needed to see this picture.

Polar sections Semliki Forest Virus

= 60r = 356, 296, 288, 272,

216, 196 A

SD Fuller et al. 1995 Cell

QuickTime™ and a decompressor

are needed to see this picture.

Radial-Depth Cueing

QuickTime™ and a decompressor

are needed to see this picture.

Reovirus

S.M. Spencer et al.,1997J of Struc. Biol.

QuickTime™ and a decompressor

are needed to see this picture.

J.M.Grimes et al. 1997 Structure

Bluetongue Virus

QuickTime™ and aH.264 decompressor

are needed to see this picture.

Reliability of Difference Imaging

• Two maps must be calculated to the same resolution and scaled in such a way that the differences are minimized.

• Double-check with another difference-map from independent reconstructions for same structure.

• Results around symmetry axes and low radius region can mislead your interpretation.

Tips : Two files in the same folder &Try to move the folder location

Modeling and Comparison with X-Ray Structures

Constrained fitting of an atomic model to low-resolution electron microscopic images can yield “pseudo-atomic precision” in which model atoms could, it was proposed, be placed with an accuracy of 4- to 5-fold better than the nominal experimental resolution, i.e. 4 Å detail could be interpreted from a map at 20 Å resolution. F. Fabiola et al. 2005 Structure

QuickTime™ and a decompressor

are needed to see this picture.

HRV14 with Fab

General outline

1. Absolute magnification of the reconstruction• accurate pixel size, comparison with X-ray

2. Matching variation in density through the reconstruction to that in the X-ray structure

• Convolve x-ray structure with CTF and match resolution• If possible, mask out extra part of EM reconstruction and

adjust two maps by comparing Fourier transforms of the projections of those maps

• Normalize EM map for positive and same range of density values as the corresponding X-ray map

• Maximum-entropy approach can be used for the treatment of CTF effects

3. Interactive fit between the EM density and the X-ray structure

• Quality of the fit : hand of the structure• Single rigid body vs multiple domains

4. Assessment of the quality and uniqueness of the fit

• R-factor : a measure of the agreement between two maps

5. Refinement in reciprocal space and in real space by objective method

Popular search and refinement methods

• Global search for initial configuration– SITUS, COAN, and DOCKEM

• Final refinement– URO, NMFF-EM, and RSRef

• Methods bridging between search and refinement– EMFIT, SITUS, and CHARMM

QuickTime™ and a decompressor

are needed to see this picture.

Refinement of the E. coli Ribosome in Its Initiation-like State with RSRef Real-Space Refinement

Gao et al. 2003 Cell

QuickTime™ and a decompressor

are needed to see this picture.

Refinement of the Myosin 10S Complex with RSRef Real-Space Refinement

Liu et al. 2003 JMB

Phasing of X-Ray Data with EM Data

• The Phase Problem of X-ray crystallography

• Classic technique to solve the Phase Problem– MIR, multiple isomorphous replacement– Useless if the crystal is not isomorphous

• EM map can be used to help solve the phase problem by applying molecular replacement– Similar molecule's phases are grafted onto the

intensities which are experimentally determined