Post on 13-Apr-2016
description
age 42 of 96
BILL OF QUANTITIES
Amount
Item Description Qty. Unit Rate Inr. Fs.
Sub – Structure
Dewatering (Contactor to check Soil Investigation Report) Item
Excavation from existing natural ground level to a required depth for Footing, Strap beams, Tie beams and service lines including necessary compaction.
m3
Backfill with selected material in layers including watering and compaction as per the spec’s & engineer’s approval.
m3
Cart away surplus excavated material off the site.
m3
Filling in plinth with selected material including watering and compction as per the spec’s & engineer’s approval. Damp proof course/DPC for block work . Applying 44mm thick water proofing membrane and two coats of hot bitumen 115/15 over it . Above Tie beam all around Villa+ above tie beam of Compound Wall.
m3
Not include
Anti - termite treatment Pre – Costruction Anti –termite treatment “Dursban 4TC”including 20 years guarantee.(Supplier shoud be approved by the Engineer)
Applied horizontally m2 Applied Vertically m2
Blinding including shuttering 50 mm thick PCC grade M 20, using SRC 250 kg/m3.
m3
Concrete grade 25 using SRC 370 Kg/M3 RCC footings m3 Column necks m3 Tie/strap/plinth Beam m3
To Collection
age 43 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
Walls 200mm thick M3 Walls 300mm thick M3 Reinforcement steel : Ton Reinforcement steel of all dia.
SOLID BLOCK WORK: 200mm thk solid block work using SR Cement Below tie beams : M2
Septic Tank and Soak away/ contractor to Include here all related concrete works or Steel, etc….. Shuttering works Sides of footing M2 Sides of walls M2 Sides and soffits of floor beams M2 Soffits of slab M2 Sides of columns necks M2 Sides of slabs M2 Soffits of staircase and landings M2 Sides of tie beams/plinth beams, sides of M2 strap beam. Entrance steps sides & riser. M2 Sundries Laying 1000 g polythene sheet M2 1 Apply two coats of butimen emulsion to M2 concrete surface in touch with soil as per spec’s and engineer’s approval. Under ground water tank (1,500 gallons)
To Collection
age 44 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
Super structure:
Walls 20mm thick M3 Columns M3 Floor beams M3 Solid slabs M3 Rib Slabs M2 Projections/ upstand / cills . M3
Staircases, steps and landings M3
Parapet and moulds M3
Foundation for A / C machines, pumps, Item water tanks etc., Grade slab 100mm thick M2 Foam concrete M3
REINFORCEMENT
Reinforcement steel of all dia. Ton A 142 – Mesh M2 Shuttering work:
Sides of walls M2 Sides of columns M2 Sides and soffits of floor beams M2 Soffits of solid slab M2 Sides of slabs M2
Soffits of staircase and landings
M2
Edge of risers M
To Collection
age 45 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
Shuttering work: [Cont’d] Sides of parapet and moulds Sides and soffit of lintels / arches M3 Sides of Projections/ upstand / cills / lintels / Arches
Generally : The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included
two coats of hot bitumen 115/15 over it . Above Tie beam all around
Villa+ above tie beam of Compound Wall
M2
Grond floor slab 4” thick M3
To Collection .
age 46 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
Block work & plaster works
A
250mm thick insulated block work Autoclaved Aerated Concrete (AAC) Thermalite blocks .
M²
B
200mm thick hollow block
M²
C
200mm thick solid block
M²
D 100mm thick hollow block work
M²
E 200mm wide damp proof course
M
F
100mm wide damp proof course
M
G Internal plaster M2
H External plaster M2 I Ceiling plaster M2 J Duct plaster M2 K Angle Beds M2 L Expanded metal M M Other balance and miscellaneous wprks Lintels including reinforcement and
shuttering:
A
200 x 150mm
LM
B
100 x 150mm
LM
C
200 x 200mm
LM
A
B
D E
BOUNDARY WALL GATES: Gate Automatic Door ( car’s Gate) Front Pedestrain Gate Builder’s Work to install the two gates: (A+B).
O.H. & Profits ( for A+B) (Cotractor to fill in the percetage bracket.)
To Collection
age 47 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
FLOOR FINISHES: Granite flooring cut to size with design and
pattern, polished smooth finish, fixed in accordance with Specifications and approval of owner and consultant. (F1) P C Rate: Granite steps with 2 strips (2cm each ) of flamed granite to avoid slipping as per specs and approval of owner and consultant .(F1a)
m2.
P.c Rate : m2. Marble flooring cut to size with design and
pattern, polished smooth finish, fixed in accordance with Specifications and approval of owner and consultant. (F2) P C rate : .
m2.
Marble steps in accordance with Specification and approval of owner and consultant. (F2a) P C rate : .. M2.
Granite Ceramic flooring , color pattern & size as per the approval of owner and consultant. (F3) P C rate : Ceramic floor tiles color , pattern and size as per the approval of owner and consultant..( F4) N.A
M2.
m2.
To Collection
age 48 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
FLOOR FINISHES: [Cont’d]
Ceramic flooring tiles (non-slippery) colour pattern & size as per the approval of owner and consultant for toilets & washrooms for toilets & wash rooms. (F5)
M2
P C rate :
Ceramic flooring tiles, colour pattern & size as per the approval of owner and consultant. (F6)
P C Rate :
M2.
Interlock 60mm thick as per the approval of owner and consultant.(F7)
l.s
Interlock 80mm thick as per the approval of owner and consultant.(F8)
l.s
Mosaic tiles as per the approval of owner and
consultant.(F9)
Precast kerbston for the approval of owner and consultant . (F11) P C Rate :
l.s
( N.A )
To Collection Inr.
age 49 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
WALL FINISHES
Fenomastic emulsion paint (Highly
Washable) from JOTUN over smooth plaster. (W1)
M2
Polyrthene Epoxy from Jotun system over
smooth plaster. ( for the external wall of villa ) (W3) Jotun semi epoxy ( Acrylic ) system over smooth plaster ( for compound wall) ( W3a)
M2
Glazed ceramic tiles cladding, colour as
per spec’s ,approval of owner &engineer. (W4) PC-rate AED15/m2
M2
CEILING FINISHES: Gypsum board ceiling with access panel as per spec’s, approval of owner and engineer (C1).
M2
Gypsum false ceiling tiles water proof type (600x600 mm) as per spec’s, approval of owner and engineer . (C2)
P.C : Rate :
M2.
Aluminium strip/tiles ceiling 10cm wide colour and patter as per approval of owner and engineer. (C3)
P.C : Rate :
M2.
To Collection
age 50 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
Fenomastic emulsion paint (Highly
Washable) from JUTON over smooth plaster.(C4)
M2
Enamel oil paint (Highly Washable) from
Jotun over smooth plaster. (C5) N.A
M2
Glass Dome skylight design, as / the
approval of of owner and engineer.(C7)
M2
Wood works for the sitting area in Roof to be quoted seperately here.
l.s
Skirting: Granite skirting (S1) m Angled granite skirting parallel to steps.
(S1a)
m
Marble skirting (S2) M Angled Marble skirting parallel to steps
slope (S2a).
M
Granite Ceramic skirting (S3) M Granite Ceramic skirting (S3a) ( N.A ) Granite Ceramic skirting (S4) (N.A) M Ceramic skirting (non - slippery) (S5) (N.A) Ceramic skirting (S6) ( N.A ) M
Sloping Mosaic tiles skirting as per the approval of owner and consultant.(S9a)
M
Generally :
The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.
To Collection
age 51 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL WORKS
Excavation and earth work for pavement works
A
Excavate to reduce levels
M³
Not include
B
Remove surplus excavated material form site
M³
Not include
C
Filling levelling with suitable soil and compacting to 95% dry density CBR 15%, generally over the site to levels as shown on Drawings
M³
Not include
ing and kerbs (outside plot limit): Pav
D
Removal of existing (if any) interlocks, cement tiles kerb stones, etc(Width required by the D M shall be borne by main contractor ). and cart away the debris
Item
Not include
rbs Precast concrete upstand ke(Outside plot limit)
Not include
E
Kerb stones on concrete beds, painting with road marking reflective black and white paint, all necessary excavation, back-filling, concrete haunching and expansion joints including flexcell boards, sealants, etc., complete
M
Not include
F
- do - for inside the building
M
Not include
Concrete interlocking blocks (Outside plot limit)
G
80mm thick, on minimum 2" thick sand, 8" thick subkha fill as per specifications and dwgs.(F8)
M²
Not include
H
- do - but 60mm thick interlock tiles(F7)
M²
Not include
Inr To Collection
age 52 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
INTERLOCK WORKS INSIDE THE : PLOT
A
60mm thk . as per the approval of the owner and the consultant . ( F7)
M²
Generally :
The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.
To Collection Inr
age 53 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
Roofing & Waterproofing
A
Minimum 50 mm thick light weight foam concrete screed density 700 kg/m3 laid to slope, Smoothly Finish to receive water proofing membrane.
M2
B
One coat of cold Bituminous primer coat As per Specification.
M2
C
4 mm thick one layer waterproofing APP membrane as per specification.
M2
D
50 mm thick Extruded polystyrene heat insulation board / Roofmate OR Equivalent Approved.
M2
E One layer of Filter membrane (min.100 g /m2.
M2
F
Mosaic tiles (25x25x2cm) over mortar
M2
G
Mosaic skirting 250mm above 30mm Layer of 10 – 15 mm dia round aggregates as per Finishing schedule
M2
H
Roofing upstand including grooved fillet with mastic sealant ,1mm thick aluminium flashing shot fired to walls as shown in drawings.
M
J Extra over for water proofing details around rain water roof outlets
No
To Collection
age 54 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
Roofing & Waterproofing [Cont’d]
WET AREAS
i
Apply water proofing as specified
ii
Horizontally
iii
Vertically
iv
90cm height of water proofing treatment to wall in contact with bath tub for toilets.
Generally :
The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included
To Collection
age 55 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
PLUMBING (WATER SUPPLY)
Contractor to submit the -Note:detailed shop drawings for water supply to the engineer before execution of work on site.
EQUIPMENT:
A
Transfer water supply pump set complete with one pump run the other standby and with necessary fitting for operations to be as per spec’s. and engineer’s approval
No.
B
Supply, install and connect ground floor Under ground tank with over head water tanks to be Fiber Glass 1000 Gallons POLYCON type as per spec’s, dwgs and engineer’s approval.
No.
C
Supply, install, fix and test booster pump sets with 2 pumps pressure vessels. The set shall be complete with steel base, strainers, non return valves, Gate valves ,Anble Valve,cut (on-off), pressure switch, pressure gauge, all softy devices, copper connections, pipes and control panels, float switch, etc. as per spec’s, dwgs and engineer’s approval.
No.
Supply and Installation of Aluminum water Proof Cat Ladder for over head water tank as per spec’s. and engineer’s approval.
No
To Collection
age 56 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
[Cont'd] PLUMBING INSTALLATIONS
DOMESTIC WATER SERVICES : PIPE WORK
Supply & Install PVC Coated Copper pipes with fittings (over false ceiling) hot & cold water supply, including all short lengths, fittings, accessories, supports and sleeves, testing, etc., complete as per spec’s. and approved shop dwgs.
A
16mm diameter M
B
25mm diameter M
Supply & Install Cross linked polyethylene pipes-PEX with fittings (from false ceiling to water outlets sanitary ware) hot & cold water supply, including all short lengths, fittings, accessories, supports and sleeves, testing, etc., complete as per spec’s. and approved shop dwgs.
A
16mm diameter M
B
25mm diameter M
C
Domestic hot water piping from water heaters to pex manifold including fittings, accessories, etc, complete
M
Supply and install of UPVC Class Pipes (for roof & Exposed areas) Insulated with Rock wool & coated by canvas , foaster and aluminium foil 2mm thk. with fittings, accessories, supports and sleeves, testing, etc., complete as per spec’s. and approved shop dwgs. M
To Collection
age 57 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
Polypropylene pipe (PPR pipes) work with solvent welded fittings, testing, etc., complete
20mm diameter No.
25mm diameter No. Supply & Install all connector pipes
between water supply line & sanitary fitting as per spec’s. No.
Installation of all pipes exposed on walls
and or below ceiling by using special galvanized steel with rubber lined. No.
Supply & Installation of all internally
exposed valves, mixers, angle, valves, and water taps to be as per the spec’s. and engineer’s approval. No.
Supply & Installation of W/C in bathroom
to be as per spec’s. and engineer’s approval.
No. No. No.
Supply & Installation of Water Pipe line
for future swimming pool to be as per spec’s. and engineer’s approval.
To Collection
age 58 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
Supply and install glass lined water heaters, power connections, testing, warranty, etc as per spec’s.
Water heater; 60 liters; horizontal
P .C : Rate
Builder’s Work:
O.H. & Profits
Contactor to fill in the percentage bracket
Installation.
( %)
Supply and install glass lined water heaters, power connections, testing, warranty, etc as per spec’s
Water heater; 80 liters; horizontal
P .C : Rate
Builder’s Work:
O.H. & Profits
Contactor to fill in the percentage bracket
Installation.
To Collection
(%)
age 59 of 96
A
DRAINAGR & STROM WATER:
and test the Supply , install, connect following UPVC under ground drains, complete with all accessories, solvent welded fittings, supports, sleeves, etc. & as per BS 4660/67 & as per specs.
40mm diameter M
B
50mm diameter M
C
80mm diameter M
D
100mm diameter M
E
150mm diameter M
F
200mm diameter M
Supply , install, connect and test the following UPVC pipe work for above ground soil, waste, rainwater and vent installations with all accessories, solvent welded fittings, supports,
, etc. & as per spec’s.sleeves
G
32mm diameter M
H
40mm diameter M
J
50mm diameter M
K
80mm diameter M
L
100mm diameter M
M
150mm diameter
M
N
200mm diameter
M
To Collection
age 60 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
MANHOLE & INSPECTION ROOMS:
FLOOR TRAPS, FLOOR DRAINS & ROOF DRAINS
Supply and install Connect and test he following floor drainst
A
UPVC (Class E) floor traps, for External use as per spec’s. & dwgs. and Engineer's approval No.
B
Stainless steel floor traps, for Internal use as per spec’s. & dwgs. and Engineer's approval No.
C
UPVC (Class E) gully trap; as per spec’s. & dwgs. and Engineer's approval. No.
D
UPVC (Class E) roof drain outlets as per spec’s. & dwgs. and Engineer's approval No.
E
UPVC (Class E) floor drain outlets as per spec’s. & dwgs. and Engineer's approval No.
MANHOLES AND GT CHAMBER
A Construct waterproof manholes 200mm reinforced concrete or solid block-work walls; 150mm thick reinforced concrete base and cover slab with opening to suit the cover and frame; benching and rendering internally; complete including all necessary excavation, back-filling, bitumen coating disposal, etc. as per spec’s. & dwgs. and Engineer's approval
No.
B Construct waterproof gully trap chambers 200mm solid block-work walls; 100mm thick reinforced concrete base and over slab with opening to suit cover and frame; complete including all necessary excavation, back-filling, disposal, etc.
No.
To Collection
age 61 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
Supply and install the following covers and frames as shown on the Drawings
A
600 x 600mm, recessed pattern, heavy-duty, double seal, with epoxy painting; for manholes
No.
B
600 x 600mm, cast iron, solid top, heavy
-duty, double seal, with epoxy painting; for manholes No.
C
300 x 300mm, recessed pattern, heavy-duty, double seal, with epoxy painting; for gully traps No.
D
300 x 300mm, cast iron, heavy duty, single seal; to all valve chambers No.
E
SANITARY WARE:
Sanitary ware and Others
Builder’s Work:
O.H. & Profits
Contactor to fill in the percentage bracket
Installation.
Generally :
The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included
To Collection
age 62 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
ELECTRICAL WORKS
A All Conduits & junction boxes should be of Ducab, Including necessary accessories as per dwgs and approval of the Engineer.
No.
No.
Supply, Installation, Testing & Commissioning of lighting fittings as per spec’s & dwgs approval of engineer for the following which includes:
No.
A Complete villa (Internal & External) No.
P.S : Builder’s Work:
O.H. & Profits
Contactor to fill in the percentage bracket
Installation.
(10 %)
Supply, Installation, Testing & Commissioning of lighting fixtures for the complete villa as per spec’s & dwgs approval of engineer for the following
A All boxes No.
B
Sockets (Internal)
No.
C Lighting switches(Internal) No.
D Sockets(External Weather proof) No.
E Lighting switches(External Weather proof) No.
To Collection
age 63 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
ELECTRICAL WORKS [cont’d]
A Power points outlets No.
B Switches cover No.
C TV points No.
D
Telephones points No.
E
Copper earth term. No.
F
Pull Box/ Junction Boxes No.
G Dimmers No.
H Switch No. (To control the external lighting)
J Earthling system No.
K
Electrical outlet cocker in kitchen(45 Amps) No.
LVC (low voltage current):
A Telephone & TV connection No.
B Telephone sockets No.
C Telephone wires No.
D Sockets (CATV System) No. POWER SOCKETS
A Supply, Installation, Testing & Commissioning of power socket outlets 220 V-13Amps MK for the complete villa as per spec’s and approval
No.
B Supply, Installation, Testing & Commissioning of shaver socket outlets 220 V-13Amps MK for the complete villa as per spec’s and approval
No.
To Collection
age 64 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
ELECTRICAL WORKS [cont’d]
C
Supply, Installation, Testing & Commissioning of twin power socket outlets 220 V-13Amps MK for the complete villa as per spec’s and approval. No.
D
Supply, Installation, Testing & Commissioning of power socket outlets 220 V-13Amps MK weather proof type for site & roof as per spec’s and approval
No.
E Supply, Installation, Testing & Commissioning of power socket outlets 220 V-45Amps MK as per dwgs, spec’s and approval .
No.
F Supply, Installation, Testing & Commissioning of power socket outlets 220 V-20Amps MK for water heater & washing machine as per dwgs, spec’s and approval .
No.
G Supply, installation, testing and commissioning of EXHAUST FANS as/spec,s dwgs. And the approval of the engineer.
No.
H Supply, installation, testing and commissioning of ELECTRIC BELL as/spec,s dwgs. And the approval of the engineer
No.
DISTRIBUTION PANEL BOARDS & METERS
Supply, Installation, Testing & Commissioning Of DISTRIBUTION PANEL BOARD 220V- 3PH 50Hz as per Schedule, spec’s and approval
No.
To Collection
age 65 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
ELECTRICAL WORKS [cont’d]
A DB-BAS.F-20KW
B DB-GF-55KW No.
C DB-AC-90KW No.
D DB-FF-45KW No.
E DB-EXT-25KW No.
F DB-WP-10KW No.
G Isolators No.
H Circuit Breaker No. POWER CABLES:
A Supply, Installation, Testing & Commissioning Of POWER CABLE 4C 70mm2 XLPE/SWA/PVC CU+1C 35MM2 Y/G AS ECC from electric meter to internal panels as per Schedule, spec’s and approval.
No.
B Supply, Installation, Testing & Commissioning Of POWER CABLE 4C 25mm2 XLPE/SWA/PVC CU+1C 16 MM2 Y/G AS ECC as per Schedule, spec’s and approval
No.
C Supply and Installation of 3- Phase Electric Meter
INTERCOM & INTERPHONE SYSTEM
Supply, Installation, Testing, Commissioning, of intercom & interphone system-Low Voltage with all necessary conduits, pull boxes, junction boxes, cables and other accessories required as /spec’s dwgs. and approval of the engineer.
Builder’s Work:
O.H. & Profits
Contactor to fill in the percentage bracket
Installation.
No.
( 10 %)
To Collection
age 66 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
ELECTRICAL WORKS [cont’d]
CENTRAL ANTENA&DISH ANTENA
SYSTEM:
Supply, Installation, Testing,
Commissioning, of the complete system
with all necessary conduits, pull boxes,
junction boxes, cables and other
accessories required as /spec’s dwgs.and
approval of the engineer. No.
Builder’s Work:
O.H. & Profits (10 %)
Contactor to fill in the percentage bracket
Installation.
:TV dishes
Conduits
Wires
Sockets (without covers)
Collection
age 67 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
A/C & VENTILATION INSTALLATIONS
Rates within this element are to include for complying with each and every clause of the preliminaries, specification and method of measurement.
Include for the complete installation as described in the specification and as shown on the Drawings to give a complete system as well as the remote remote controlled thermostats, pipeing, ducting and insulation related to ducts and pipes and the control is separate for each room and space is acceptable to the Engineer and all local authorities and under the following sections
A Ducted split units including all supports, anti-vibration, mountings refrigerant pipes charge, accessories and integral controls as per schedules & spec’s, No.
Builder’s Work:
O.H. & Profits ( 15 %)
Contactor to fill in the percentage bracket Installation.
Contractor to quote seperately :
A Civil & electrical works related to A/C,
B All plumbing works
C Sleeves (PVC) for GAS route for protection
D shops drawing for all A/c works
E R.C.C. pads
To Collection
age 68 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
ALUMINUM DOORS & WINDOWS
All Aluminum sections to be heavy duty powder coated 80 micron with the desired color and section 10.5 cm for windows, 12.5cm for doors, and box sections for all sliding panels and doors to be provided with fly mesh from inside , with necessary accessories.
Doors:
No
No.
Glazed Windows:
W1 No.
KW1
No.
W2
W3
No.
EW1
EW2
EW3
CW1
CW2(curtain wall)
CW5
DW1
To Collection
age 69 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
A
: CAT & SPIRAL LADDERS
Supply & Installation of CAT & SPIRAL LADDERS from ground floor to terrace & then to roof as per Shop dwgs and Approval of Engineer
No.
A
RAILS:
Internal Railing : (staircase)
Supply & Installation of Aluminum powder coated railing as per details and Approval of Engineer.
P.C. Rate :
r m
B
External Railing :
Supply & Installation of Decorative Cast Aluminum coated railing as per details and Approval of Engineer.
P.C. Rate :
r m
Powder coated aluminum canopy/wooden Pergola
On first floor terrace contractor to consider as provisional sum of total value . N.A
Builders work :
O.H &profits
%(10 )
Generally :
The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.
To Collection
age 70 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
JOINARY WORKS: (Wooden)
All the external Doors to be Burma teak
Wood with bronze bolts and other ironmongery as per spec’s, dwgs and approval of the engineer.
A P.C Rate : no
Supply :
Installation:
D Supply and installation of All Internal Doors as per spec’s, dwgs and approval of the engineer.
P.S Rate :
No.
Supply :
Installation
E
Supply and installation of Sub-Frames for all doors as per spec’s, dwgs and approval of the engineer.
No.
To Collection
age 71 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
WARDROBES:
Supply & Installation of wardrobes for all Bed / Dressing room as per spec’s and Approval of Engineer.
P.S : Builder’s Work
O.H. & Profits
Contractor to fill in the percentage Bracket
( 10 %)
CAR SHED:
Car Shed roof G R P panel as per the approved shop dwgs and Engineer’s Approval/ C6 M2
P.S :
Builder’s Work O.H. & Profits
Contractor to fill in the percentage Bracket
( 10 %)
STONE CLADDING IN CORNERS OF VILLA: As shown in drawings. M2 N.A.
GRC DECORATION PYRAMIDS ON ELEVATIONS: As shown in elevations. No. A.N
To Collection
age 72 of 96
Item Description Qty. Unit Rate Inr. Fs.
KITCHEN CABINETS
Supply & Installation of Kitchen cabinets
In Ground as per spec’s and Approval of Engineer.
P.S : Rate :
Builder’s Work :
O.H. & Profits
VANITY COUNTERS
Supply & Install Vanity Counters in Ground floor(as per drawings)for wash & toilets etc., as per spec’s and approval of the engineer.
P.C : Rate :
M2
RM
(10 %)
1
Genarally:
The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included
To Collection Inr
age 73 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
COMPOUND WALL :
Sub - structure:
Excavation from existing natural ground level to a required depth for Footing including necessary compaction. M3
Backfill with selected material in layers including watering and compaction M3
Cart away surplus excavated material off the site.
Damp proof course/ DPC for block work .Applaying 4mm thick water proofing membrane and two coats of hot birumen 115/15 over it / Above tie beam. M3
Blinding including shuttering 50 mm thick PCC grade M 20, using SRC 250 kg/m3. M3
Concrete grade 30 using SRC 370 Kg/M3 RCC footings M3
Reinforcement steel of all dia.
tons 200mm thk solid block work using SR M2 Shuttering works Sides of footing M2 Sundries Laying 1000 g polythene sheet M2 Apply two coats of butimen emulsion to
concrete surface in touch with soil as per spec’s and engineer’s approval. M2
Super structure:
Concrete grade 30/20 using OPC 370 kg/m3
Columns m3 Coping Beams M3
To Collection
age 74 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
[Cont’d]COMPOUND WALL:
Block Work:
200mm wide damp proof course m
200mm thick hollw block work M WALL FINISHES: Jotun Semi epoxy system over smooth
plaster. (W------) M2
Electrical Works:
Supply, Installation, Testing & Commissioning of All Electrical works for the compound wall as per spec’s & dwgs approval of engineer for the following
Genarally:
The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included
To Collection
age 75 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL SERVICE BLOCK: Sub – Structure
Dewatering (Contactor to check Soil Investigation Report) Item
Excavation from existing natural ground level to a required depth for Footing, Strap beams, Tie beams and service lines including necessary compaction.
m3
Backfill with selected material in layers including watering and compaction as per the spec’s & engineer’s approval.
m3
Cart away surplus excavated material off the site.
m3
Filling in plinth with selected material including watering and compction as per the spec’s & engineer’s approval.
m3
Damp proof course/DPC for block work .Applaying 4mm thick water proofing membrane and two coats of hot birumen 115/15 over it / Above tie beam.
Anti - termite treatment Pre – Costruction Anti –termite treatment “Dursban 4TC”including 20 years guarantee.(Supplier shoud be approved by the Engineer)
Applied horizontally m2
Blinding including shuttering 50 mm thick PCC grade M 20, using SRC 250 kg/m3.
m3
Concrete grade 30 using SRC 370 Kg/M3 RCC footings m3
Column necks
m3
Tie/strap/plinth Beam m3
To Collection
age 76 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK [con’d]
Reinforcement steel : Ton Reinforcement steel of all dia.
SOLID BLOCK WORK: 200mm thk solid block work using SR cement : Below tie beams M2 Shuttering works Sides of footing M2 Sides of columns necks M2 Sides of tie beams/plinth beams, sides of strap beam. M2 Entrance steps sides & riser. M2 Sundries Laying 1000 g polythene sheet M2 Apply two coats of butimen emulsion to concrete surface in touch with soil as per spec’s and engineer’s approval. M2
Generally : The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.
To Collection
age 77 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK : [Cont’d]
Super structure:
Walls 20mm thick M3 Columns M3 Floor beams M3 Solid slabs M3 Hourdy Rib slabs M2 Projections/ upstand / cills . M3 Staircases, steps and landings M3
Parapet and moulds M3
Foundation for A / C machines, pumps, Item water tanks etc., Grade slab 100mm thick M2
REINFORCEMENT
Reinforcement steel of all dia. Ton A 142 – Mesh M2 Shuttering work:
Sides of walls M2 Sides of columns M2 Sides and soffits of floor beams M2 Soffits of solid slab M2 Sides of slabs M2
Soffits of staircase and landings
M2
Edge of risers M
To Collection
age 78 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK : [con’d]
Shuttering work: [Cont’d] Sides of parapet and moulds Sides and soffit of lintels / arches Sides of Projections/ upstand / cills / lintels / Arches Block work & plaster Works 250mm thick insulated block work
Autoclaved Aerated Concrete (AAC) Thermalite blocks .
M2
200mm thick hollow block M2
200mm thick solid block M2
100mm thick hollow block work M2 200mm wide damp proof course M2 100mm wide damp proof course M2 Internal plaster M2 External plaster M2 Ceiling plaster M2 Duct plaster M2 Angle Beds M2 Expanded metal M Other balance and miscellaneous wprks Lintels including reinforcement and
shuttering:
200 x 150mm 100 x 150mm 200 x 200mm
To Collection
age 79 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK [con’d]
FLOOR FINISHES: Ceramic flooring tiles (non-slippery) colour
pattern & size as per the approval of owner and consultant for toilets & washrooms for toilets & wash rooms. (F5)
P C rate : M2 Ceramic flooring tiles colour pattern & size
as per the approval of owner and consultant. (F6)
P C Rate :
Mosaic tiles as per the approval of owner and
consultant .( F9)
M2
WALL FINISHES
Fenomastic emulsion paint (Highly Washable) from JOTUN over smooth plaster. (W1)
M2
Jotun polytheren system over smooth
plaster .( External walls only ) . (W3)
M2
Glazed ceramic tiles cladding, colour as
per spec’s ,approval of owner &engineer. (W4)
M2
CEILING FINISHES
Fenomastic emulsion paint (Highly Washable) from JUTUN over smooth plaster.(C4)
Enamel oil paint ( Highly washable ) over
smooth plaster ( C5)
M2
To Collection
age 80 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK: [con’d]
Skirting: Ceramic skirting (S6)
Slopping mosaic tiles skirting (S9)
M2
EXTERNAL WORKS
M2
Excavation and earth work for pavement works
Excavate to reduce levels
Remove surplus excavated material form
site
M2
Filling levelling with suitable soil and
compacting to 95% dry density CBR 15%, generally over the site to levels as shown on Drawings
M2
Precast concrete upstand kerbs M2 Kerb stones on concrete beds, painting
with road marking reflective black and white paint, all necessary excavation, back-filling, concrete haunching and expansion joints including flexcell boards, sealants, etc., complete
M2
Concrete interlocking blocks 60mm thick, on minimum 2" thick sand, 8"
thick subkha fill as per specifications and dwgs.
To Collection
age 81 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK [con’d]
Roofing & Waterproofing
A
Minimum 50 mm thick light weight foam concrete screed density 700 kg/m3 laid to slope, Smoothly Finish to receive water proofing membrane.
M2
B
One coat of cold Bituminous primer coat As per Specification.
M2
C
4 mm thick one layer waterproofing APP membrane as per specification.
M2
D
50 mm thick Extruded polystyrene heat insulation board / Roofmate OR Equivalent Approved.
M2
E One layer of Filter membrane (min.100 g /m2.
M2
F
Mosaic tiles (25x25x2cm) over mortar
M2
G
Mosaic skirting 250mm above 30mm Layer of 10 – 15 mm dia round aggregates as per Finishing schedule
M2
H
Roofing upstand including grooved fillet with mastic sealant ,1mm thick aluminium flashing shot fired to walls as shown in drawings.
M
J Extra over for water proofing details around rain water roof outlets
No
To Collection
age 82 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK [con’d]
[Cont'd] PLUMBING INSTALLATIONS
DOMESTIC WATER SERVICES : PIPE WORK
Supply & Install PVC Coated Copper pipes with fittings (over false ceiling) hot & cold water supply, including all short lengths, fittings, accessories, supports and sleeves, testing, etc., complete as per spec’s. and approved shop dwgs.
A
16mm diameter M
B
25mm diameter M
Supply & Install Cross linked polyethylene pipes-PEX with fittings (from false ceiling to water outlets sanitary ware) hot & cold water supply, including all short lengths, fittings, accessories, supports and sleeves, testing, etc., complete as per spec’s. and approved shop dwgs.
A
16mm diameter M
B
25mm diameter M
C
Domestic hot water piping from water heaters to pex manifold including fittings, accessories, etc, complete
M
Supply and install of UPVC Class Pipes (for roof & Exposed areas) Insulated with Rock wool & coated by canvas , foaster and aluminium foil 2mm thk. with fittings, accessories, supports and sleeves, testing, etc., complete as per spec’s. and approved shop dwgs. M
To Collection
age 83 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK [con’d]
Polypropylene pipe (PPR pipes) work with solvent welded fittings, testing, etc., complete
20mm diameter No.
25mm diameter No. Supply & Install all connector pipes
between water supply line & sanitary fitting as per spec’s. No.
Installation of all pipes exposed on walls
and or below ceiling by using special galvanized steel with rubber lined. No.
Supply & Installation of all internally
exposed valves, mixers, angle, valves, and water taps to be as per the spec’s. and engineer’s approval. No.
Supply & Installation of W/C in bathroom
to be as per spec’s. and engineer’s approval.
No. No. No.
Supply and install glass lined water
heaters, power connections, testing, warranty, etc as per spec’s. No.
Water heater; 60 liters; horizontal
P .C : Rate AED 350
Builder’s Work:
O.H. & Profits
Contactor to fill in the percentage bracket
Installation. No. No.
To Collection
age 84 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK [con’d]
DRAINAGR & STROM WATER:
Supply , install, connect and test the following UPVC under ground drains, complete with all accessories, solvent welded fittings, supports, sleeves, etc. & as per BS 4660/67 & as per specs.
40mm diameter
B 50mm diameter M
C 80mm diameter M 100mm diamete 150mm diameter 200mm diameter
Supply , install, connect and test the following UPVC pipe work for above ground soil, waste, rainwater and vent
ll accessories, installations with asolvent welded fittings, supports, sleeves, etc. & as per spec’s.
32mm diameter 40mm diameter 50mm diameter 80mm diameter 100mm diameter 150mm diameter No.
To Collection
age 85 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK [con’d]
MANHOLE & INSPECTION ROOMS:
OOR TRAPS, FLOOR DRAINS & FLROOF DRAINS
Supply and install Connect and test the following floor drains
A
UPVC (Class E) floor traps, for External use as per spec’s. & dwgs. and Engineer's approval No.
B
Stainless steel floor traps, for Internal use as per spec’s. & dwgs. and Engineer's approval No.
C
UPVC (Class E) gully trap; as per spec’s. & dwgs. and Engineer's approval. No.
D
UPVC (Class E) roof drain outlets as per spec’s. & dwgs. and Engineer's approval No.
E
UPVC (Class E) floor drain outlets as per spec’s. & dwgs. and Engineer's approval No.
MANHOLES AND GT CHAMBER
A Construct waterproof manholes 200mm reinforced concrete or solid block-work walls; 150mm thick reinforced concrete base and cover slab with opening to suit the cover and frame; benching and rendering internally; complete including all necessary excavation, back-filling, bitumen coating disposal, etc. as per spec’s. & dwgs. and Engineer's approval
No.
B Construct waterproof gully trap chambers 200mm solid block-work walls; 100mm thick reinforced concrete base and over slab with opening to suit cover and frame; complete including all necessary excavation, back-filling, disposal, etc.
No.
To Collection
age 86 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK [con’d]
Supply and install the following covers and frames as shown on the Drawings
A
600 x 600mm, recessed pattern, heavy-duty, double seal, with epoxy painting; for manholes
No.
B
600 x 600mm, cast iron, solid top, heavy
-duty, double seal, with epoxy painting; for manholes No.
C
300 x 300mm, recessed pattern, heavy-duty, double seal, with epoxy painting; for gully traps No.
D
300 x 300mm, cast iron, heavy duty, single seal; to all valve chambers No.
Generally :
The contractor will list here and price items shown on the drgs., mentioned in the specification or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included
SANITARY WARE :
Sanitary ware and Others
Builder’s Work:
O.H. & Profits
Contactor to fill in the percentage bracket
Installation.
(10 %)
To Collection
age 87 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK [con’d]
ELECTRICAL WORKS
A All Conduits & junction boxes should be of Ducab, Including necessary accessories as per dwgs and approval of the Engineer.
No.
No.
Supply, Installation, Testing & Commissioning of lighting fittings as per spec’s & dwgs approval of engineer for the following which includes:
No.
External Block
Builder’s Work:
O.H. & Profits
Contactor to fill in the percentage bracket
Installation.
( 10 %)
Supply, Installation, Testing & Commissioning of lighting fixtures for external block as per spec’s & dwgs approval of engineer for the following
A All boxes No.
B
Sockets (Internal)
No.
C Lighting switches(Internal) No.
D Sockets(External Weather proof) No.
E Lighting switches(External Weather proof) No.
To Collection
age 88 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK [con’d]
ELECTRICAL WORKS [cont’d]
A Power points outlets No.
B Switches cover No.
C TV points No.
D
Telephones points No.
E
Copper earth term. No.
F
Pull Box/ Junction Boxes No.
G Dimmers No.
H Switch No. (To control the external lighting)
J Earthling system No.
K
Electrical outlet cocker in kitchen(45 Amps) No.
LVC (low voltage current):
A Telephone & TV connection No.
B Telephone sockets No.
C Telephone wires No.
D Sockets (CATV System) No. POWER SOCKETS
A Supply, Installation, Testing & Commissioning of power socket outlets 220 V-13Amps MK as per spec’s and approval
No.
B Supply, Installation, Testing & Commissioning of shaver socket outlets 220 V-13Amps MK as per spec’s and approval
No.
To Collection
age 89 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK [con’d]
ELECTRICAL WORKS [cont’d]
C
Supply, Installation, Testing & Commissioning of twin power socket outlets 220 V-13Amps MK as per spec’s and approval. No.
D
Supply, Installation, Testing & Commissioning of power socket outlets 220 V-13Amps MK weather proof type for site & roof as per spec’s and approval
No.
E Supply, Installation, Testing & Commissioning of power socket outlets 220 V-45Amps MK as per dwgs, spec’s and approval .
No.
F Supply, Installation, Testing & Commissioning of power socket outlets 220 V-20Amps MK for water heater & washing machine as per dwgs, spec’s and approval .
No.
G Supply, installation, testing and commissioning of EXHAUST FANS as/spec,s dwgs. And the approval of the engineer.
No.
To Collection
age 90 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK [con’d] A/C & VENTILATION INSTALLATIONS
Rates within this element are to include for complying with each and every clause of the preliminaries, specification and method of measurement.
Include for the complete installation as described in the specification and as shown on the Drawings to give a complete system as well as the remote remote controlled thermostats, pipeing, ducting and insulation related to ducts and pipes and the control is separate for each room and space is acceptable to the Engineer and all local authorities and under the following sections
A Split units Decorative type mountings charge, accessories as per schedules & spec’s,
No.
Builder’s Work:
O.H. & Profits ( 10 %)
Contactor to fill in the percentage bracket Installation.
Contractor to quote seperately :
A Civil & electrical works related to A/C,
B All plumbing works
C Sleeves (PVC) for GAS route for protection
D shops drawing for all A/c works
E R.C.C. pads
To Collection
age 91 of 96
Amount
Item Description Qty. Unit Rate Inr. Fs.
EXTERNAL BLOCK [con’d]
ALUMINUM DOORS & WINDOWS
All Aluminum sections to be heavy duty powder coated 80 micron with the desired color and section 10.5 cm for windows, 12.5cm for doors, and box sections for all sliding panels and doors to be provided with fly mesh from inside , with necessary accessories.
Doors:
A
ED1:
No
B ED2
Glazed Windows:
A
EW1:
No.
B
EW2
No.
C
EW0
JOINARY WORKS: (Wooden)
Supply and installation of All Internal
Doors as per spec’s, dwgs and approval of the engineer.
D2,D3,D5 : -
Supply and installation of Sub-Frames for
all doors as per spec’s, dwgs and approval of the engine
Kitchen cabinet :
P.S rate
Builders work :
O.H & profits
( 10 )%
Shelves at store :
P.S Rate
Builders Work :
O.H & Profits
( 10 ) %
To Collection