Model T9000 Electro-Pneumatic Pressure Controller …fairchildproducts.com/pdf/Press Quality...

Post on 10-Jun-2018

224 views 0 download

Transcript of Model T9000 Electro-Pneumatic Pressure Controller …fairchildproducts.com/pdf/Press Quality...

Model T9000 Electro-Pneumatic Pressure Controller

121

FeaturesCommon Features of the T9000 Products•Fullyfunctionalkeypadanddisplay.•BacklitLiquidCrystaldisplayscreen.•Output pressure displays in psig, BAR, kPa,oruser-definedpressureunits.•Independently adjustable PIDtuning coefficients.•Reverse acting capability for analog input andoutputsignals.•Select Current or Voltage mode for input signal or optional analog channels using thekeypad.•RFI/EMIprotectioneliminates electromagneticandradiointerference.

Operating PrinciplesThe Model T9000 Ser ies PressureControllers have a closed-loop, integrated,microprocessorcontrolsystemthatregulatesoutlet pressure. You can control the outputfrom the Model T9000 products using thekeypad or from an analog control signal.You can control the output from theModelT9000D using the keypad and throughDeviceNetTMCommunicationnetwork.

The Feed and Bleed Solenoid Valvescontrol pressure in the Signal Chamberof the Booster Section. A pressure sensormeasures the outlet pressure and providesafeedbacksignaltotheElectronicsSection.Any variation in pressure between thesetpoint and the outlet pressure activatesthe Feed and Bleed Solenoid Valves tocorrecttheoutputpressure.

BModel T9000

800-334-8422www.fairchildproducts.com

T9000

T9020

T9060

T9080

T9040

T9010

BModel T9000

122 800-334-8422www.fairchildproducts.com

T9000

0

30

60

90

120

150

-20 0 20 40 60 80 100 120 140

Supply Pressure = 150 PSIG

Setpoint = 30 PSIG

Setpoint = 60 PSIG

Setpoint = 90 PSIG

Setpoint = 120 PSIG

Air Flow, SCFM

Outpu

t Pres

sure,

PSIG

Flow CharacteristicsT9040-4074N4FJT Pressure Controller

T9010

Model T9000 Electro-Pneumatic Transducer

T9020 SeeT9000ForTopView

0

30

60

90

120

150

-10 0 10 20 30 40 50 60 70 80 90 100

Supply Pressure = 150 PSIG

Setpoint = 30 PSIG

Setpoint = 60 PSIG

Setpoint = 90 PSIG

Setpoint = 120 PSIG

Air Flow, SCFM

Outpu

t Pres

sure, P

SIG

Flow CharacteristicsT9020-4072N4NFS Pressure Controller

T9040 SeeT9000ForTopView

T9060 T9080

123 800-334-8422www.fairchildproducts.com

Model T9000 Electro-Pneumatic Transducer

0

30

60

90

120

150

0 50 100 150 200 250

Supply Pressure = 150 PSIG

Setpoint = 30 PSIG

Setpoint = 60 PSIG

Setpoint = 90 PSIG

Setpoint = 120 PSIG

Air Flow, SCFM

Out

put P

ress

ure,

PSI

G

Flow CharacteristicsT9060-4074N4FNT Pressure Controller

Model T9000

FlowCharacteristicsChart Foward Exhaust150psig[10BAR]Supply60psig[4BAR]DownstreamPressure

T9000T9010 T9020 T9040 T9060T9080

1SCFM12SCFM90SCFM110SCFM220SCFM700SCFM

-4SCFM45SCFM55SCFM110SCFM350SCFM

Model T9000 Electro-Pneumatic Transducer

124

InstallationFor operating instructions, refer to the corresponding FairchildOperation and Maintenance Instructions, OM-500T90FI,OM-500T90AB,OM-500T90AO,OM-500T90DB,OM-500T90DI,OM-500T90DO.

Forinstallationinstructions,refertoII-500T9000.

Catalog InformationSpecificationsSupply Pressure1200psig,[14BAR],(1400kPa)MaximumPneumatic Outputs psig: 0-30 0-75 0-150 [BAR]: [0-2] [0-5] [ 0 - 1 0 ] (kPa): (0-200) (0-500) (0-1000) Minimum Span psig: 12 30 6 0 [BAR]: [0.8] [2.0] [ 4 . 0 ] (kPa): (80) (200) (400)

Input Signal4-20mA,0-10VDCFlow Rate1-700SCFM(Selectdesiredconfiguration)Exhaust Flow 1-350SCFM(Selectdesiredconfiguration)

Air Consumption 0@steadystateoutputwithDeadband@1%ofFullScale Supply Pressure EffectNoMeasurableEffectElectrical Supply24VDC±10%Power ConsumptionLessthan5wattsAnalog Output Signal / Impedence4-20mA/500ohmsMaximum,0-10VDC/400ohmsMinimumDeadband (ISA S51.1)Adjustablefrom0to10%ofFullScaleUnit Accuracy (ISA S51.1)Lessthan0.50%OutputSpanFrequency Response-3db@1HZperISAS26.4.3.1loadConfigurationA(typicalbutdependsonspecificT9000productconfiguration)Vibration EffectLessthan1%ofSpanunderthefollowingconditions:5-15Hz@0.8inchesconstantdisplacement15-500Hz@10g’sRFI/EMI EffectLess than 0.5%. EMC Directive 89/336/EEC EuropeanNormsEN50081-2&EN50082-2.Temperature Range0°Fto+160°F,(-18°Cto+71°C)Materials of Construction BodyHousing........Polymer,ChromateTreatedAluminumTrim........................................................ ZincPlatedSteelElastomers......................................... Nitrile,FluorocarbonFinish........................................................................Epoxy1 Supply Pressure must be no less than 5 psig, [0.35 BAR], (35 kPa) above

maximum output.

800-334-8422www.fairchildproducts.com

BModel T9000

Catalog Number T90

Flow Rate1 SCFM (Basic Transducer) ....... 0012 SCFM ……………………......... 1090 SCFM ……………………......... 20110 SCFM …………………......... 40220 SCFM……………………........ 60700 SCFM ……………………....... 80

Input0-10 VDC . . . . . . . . . . . . . . . . . . . . . . . 04-20 mA . . . . . . . . . . . . . . . . . . . . . . . . 4DeviceNet TM. . . . . . . . . . . . . . . . . . . . . . D

Output0-30 psig. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 040-75 psig. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 050-150 psig. . . . . . . . . . . . . . . . . . . . . . . . . . . . 07[0-2.0 BAR] . . . . . . . . . . . . . . . . . . . . . . . . . . . 14[0-5.0 BAR] . . . . . . . . . . . . . . . . . . . . . . . . . . . 15[0-10.0 BAR] . . . . . . . . . . . . . . . . . . . . . . . . . . 17(0-200 kPa). . . . . . . . . . . . . . . . . . . . . . . . . . . 24(0-500 kPa). . . . . . . . . . . . . . . . . . . . . . . . . . . 25(0-1000 kPa). . . . . . . . . . . . . . . . . . . . . . . . . . 27

Port Size1/4" NPT (T9000,10,20,40 only) . . . . . . . . . . . . . 023/8" NPT (T9020,40 only) . . . . . . . . . . . . . . . . . . 031/2” NPT (T9020,40 only) . . . . . . . . . . . . . . . . . . 043/4” NPT (T9060,80 only) . . . . . . . . . . . . . . . . . . 061” NPT (T9080 only) . . . . . . . . . . . . . . . . . . . . . . 08

Port ThreadsNPTF Thread . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBSPT Thread . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UBSPP Thread (Not Available on T9010) . . . . . . . . . . . . . . . . H

Feedback OptionNone. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N0-10 VDC Analog Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04-20 MA Analog Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-10 VDC Feedback Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54-20 MA Feedback Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

ElastomersNitrile (Not available in T9040). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NFluorocarbon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J

Power Failure ModeFreeze (Maintains Setpoint) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F

Exhaust PortTapped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E

Remote Pressure Sensing Capability (see table below)Unique Feature of the T9000D•DeviceNetTMCommunicationsconnecttheModelT9000D toadigitalnetworktoincreasefunctionalflexibility, installationspeed,andreducesystemwiringcost.

Available Options for the T9000 Series Transducer•Optionalanalogoutputchannelconfiguredasanoutput pressuremonitororasauser-definedoutput.•ExternalPneumaticFeedbackporttosensedownstream pressure.(SeeCablesandAccessoriestable)•OptionalFeedbackInputChannelconfigurabletocontrol setpoint,externalprocessvariable,oracceptauser definedinput.(Consultfactoryforavailability.)

T9000 Cables and Accessories (sold separately)

Part Number Description 032-IPI-018-2Straight,Shielded6pinFemale032-IPI-019-2Rightangle,Shielded6pinFemale032-IPI-009-2FStraight,ShieldedCableforDeviceNet™032-IPI-009-2R Rightangle,ShieldedCableforDeviceNet™21665-1N1/8-27NPTFRemotePressureSensorfitting21665-1U1/8-28BSPTRemotePressureSensorfitting