Post on 20-Apr-2018
LDR Treatment Planning System for Prostate
TD-211 04-11-2017
MIM Software Beijing Co., Ltd.
北京明维视景医疗软件开发有限公司地址: 北京市海淀区苏州街29号维亚大厦605室,邮编100080
电话 86-10-82626590邮箱 info@mimsoftware.com
MIM Software Inc.
25800 Science Park Drive - Suite 180Cleveland, OH 44122
866-421-2536www.mimsoftware.cominfo@mimsoftware.com
© MIM Software Inc. 2017 All Rights Reserved
MIM Software Brussels BVBA
Drukpersstraat 41000 BrusselBelgium
(32) 485 473 416info@mimsoftware.com
Emergo EuropePrinsessegracht 20 2514 AP The Hague The Netherlands
200% Pre-Plan Dose Cloud
3D Rendering of Pre-Plan
TM
MIM Software™ is an industry leader in clinical
automation and workflow customization valued by
more than 3000 centers globally. With this knowledge,
MIM developed MIM Symphony LDR™ for Prostate.
Why MIM?
Pre-PlanContouring Tools for Efficiency
• Industry-leading contouring tools
• One-click interpolation
• Multiplanar brush and pen capability
with copy and edit functions
• One-step contouring of urethra and
femoral heads using 3D brush
Planning for Improved Outcomes
• Automatic and manual placement
modes for both strands and seeds
• Accommodates angled needles
• Auto-placement of needle positions
throughout the gland using
the Plan Library
• Rapid dosimetry enabled by a self-
directed, ever-expanding Plan Library
QA Tools for Consistency
• Unlimited dose constraint alerts in Pre-op mode
• Physician and Physicist remote plan approval using MIMcloud™
Reach for MIM Symphony LDR™
• Ultrasound-guided planning with your existing ultrasound
• MRI and CT-guided planning
• Fully-featured without add-on modules Why Plan Libraries?
A Plan Library continually grows as each new plan is
created. Plans are automatically selected by matching
the contours for your current patient with the library.
In selecting previous implant plans, the plan you adopt
will be consistent with your typical treatment strategy.
Intra-OpImage Acquisition Efficiencies
• Rapid fusion of MRI contours with automatic capture of transverse images
• Customizable image acquisition methods including:
• Frame-by-frame capture
• BK Ultrasound, Hitachi®, or GE Digital™ formats
• Import of DICOM image sets from CT, MRI, or US
• Export in DICOM format structures, images, and dose information
• Engage Predictive Fusion™ to reorient the prostate into Lithotomy position
Intuitive QA
• Customizable dose constraints easily reviewed on the User Interface
• Unlimited number of dosimetric alerts
105.0
102.5
100.0
97.5
95.0
92.5
90.0
87.5
85.0
82.5
80.0
77.5
75.0
72.5
70.0
67.5
65.0
62.5
60.0
57.5
55.0
52.5
50.0
47.5
45.0
42.5
42.5
40.0
37.5
35.0
32.5
30.0
27.5
25.0
22.5
20.0
17.5
15.0
12.5
10.0
7.5
5.0
2.5
0.00 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240
Dose (Gy)
NameurethrarectumprostatePTV
Volume0.3531.6626.3441.53
Max Dose237.76662.2831.4925.8
Min Dose1061.244.225.88
Mean Dose136.6524.44190.42175.73
SD17.2536.2101.63108.18
Included: urethra (5)V: 100.0 %0.35 mlD: 81.60 Gy
Pre-Plan Dose Volume Histogram (DVH)
MR-Based Pre-Plan
Why Predictive Fusion™?
• MIM's Predictive Fusion technology reorients the MRI image set
• In Pre-Plan phase, MIM Symphony LDR predicts the ideal overlay, or fusion, of the MRI prostate volume onto the live ultrasound prior to the seed implant
• Benefits include reduced probe dwell time, less deformation in your plan, and shortened fusion time
Reduce Probe Dwell Time with Less Deformation
To learn more, call 866-421-2536 or visit mimsoftware.com/contact to schedule a presentation of MIM Symphony LDR.
350
325
300
275
250
225
200
175
150
125
100
75
50
25
00 60 120 180 240
Reporting Your Plan
• Customizable for Pre-Plan, Intra-op, and Post-op
• Detailed needle loading and strand cutting
• DVH on any contoured structure within the 3D volume
System and Source Management
• Archive patient databases for treatment data and images
• Configure “Source” data and easily add new energies
• Supports TG43 dose calculation formalism
Customizable Reporting Tools
MRI FusionFuse MRI’s to Post-op CT which ensures more accurate contouring and dosimetry
• Maximum Intensity Projection (MIP) Seed Navigator -
The configurable seed locator is tunable to match specific
imaging equipment and its Hounsfeld unit intensity
• Dosimetric Quality Alerts - Monitor dosimetric
constraints based on your prescribed parameters
• On-Demand Dose Coverage Review -
Acquire Active DVH on any contoured structure
within the 3D volume of the prostate
Post-implant Dosimetry of the Fused MR to the Post-implant CT