HVAC Comfort with NEX and PLAY - Reliability or Flexibility?

Post on 17-Jul-2015

300 views 1 download

Tags:

Transcript of HVAC Comfort with NEX and PLAY - Reliability or Flexibility?

Innovative Solutions to Improve Comfort & EfficiencyNEX and PLAY

Discomfort is Expansive

Office Building• Average HVAC technician service call:

$400

• Absenteeism

• Decreased employee performance

• Cost of over heating and over cooling

• Extreme cases of losing employees: cost of re-hiring, re-training, loss of productivity

What about a restaurant?

• Seating capacity: 300

• Open 360 nights / year

• Average 1 dinner / seat / night

• Total 108,000 customers / year

• Some feel air distribution-related discomfort

• 2% of customers would've stayed a bit longer if slightly more comfortable, just enough to buy one last drink or dessert

• Average gross profit per drink or dessert: $3

• Seating capacity: 300

• Open 360 nights / year

• Average 1 dinner / seat / night

• Total 108,000 customers / year

• Some feel air distribution-related discomfort

• 2% of customers would've stayed a bit longer if slightly more comfortable, just enough to buy one last drink or dessert

• Average gross profit per drink or dessert: $3

$6,840 profit / yearConsequence:

Common sources of air distribution related

discomfort

A well designed HVAC System

Performs really well in theoretical or average

conditions

Cold air supplied at low velocity

... Will drop from standard diffusers

While at higher velocity...

Air jets collide and are deflected

How can we improve performance in VAV

applications?

Using a diffuser providing higher tolerance to velocity and temperature variations.

NEX Concave Elements

• Won a new products contest as the Best Heating Component

• Also ideal for cooling and VAV applications

• Innovative architectural look

NEX Concave Elements

• Swirl pattern

• Air diffused in multiple jets of various velocities

• High induction ratio, mixes more air, faster and more evenly

• Higher tolerance to temperature and velocity variations

Another very common issue causing discomfort

• Flex duct with kink or angle

• Up to 80% of airflow could be diffused in one direction

• Same issue with rigid duct and 90 degree elbows

In theory, ASHRAE recommends

• Rarely happens in real world

• Most of the time, not enough space in the ceiling

• Sometimes installer just lazy, poorly trained or trying to save on time and material

NEX + PERFAIR

• 2 layers of air equalizing

• First layer: damper + equalizer integrated in plenum's neck

• Second layer: the Concave Elements. No direct exit, air is forced to swirl inside the plenum

Energy Efficiency

• Stratification & uneven mixing of supplied air with room air causing inaccurate or varying measurements of thermostat and humidistat

• Can result in over-heating / over-cooling

• Equipment on/off and modulation = more energy used to achieve same result as steady conditioning

Return on InvestmentAn HVAC system is a chain of components

A chain is only as strong as its weakest link

Cost adds up... Not Performance!

What about unpredictable factors?

• At design time, impossible to know and plan for everything

• Added furniture and decorative objects might obstruct and deflect air jets

• Cubicle layout modified

• Each individual's tolerance to hot and cold

Solutions available so far

• Blocking air in one or more directions

• Air volume control damper

• Adjustable diffusers, from horizontal to vertical airflow

• VAV diffusers, expansive to purchase and to install

The new solution

PLAY Adjustable Sectors

• Only diffuser allowing for full horizontal adjustment

• Easy to adjust, from the face and without tools

• 1, 2, 3, 4 way and swirl with easy sectors positioning

• Can also be adjusted by as many degrees as required to avoid people and objects

• Innovative architectural look

Example 1 - Cubicle Layout

7/8 comfort ratio1 person complains about the cold

Solution 1 : adjust damper to reduce the volume of cold air

supplied

5/8 comfort ratio

Solution 2 : block one way

5/8 comfort ratio

Solution 3 : block one way + adjust damper for less volume

7/8 comfort ratio

PLAY Solution: adjust horizontal angle just enough to fix issue

8/8 comfort ratio

From Above

From Above

Solved the comfort issue...

In the most energy efficient way

PLAY Adjustable Sectors

• Gives flexibility to quickly solve air distribution issues

• Fewer and cheaper service calls

• Increased general level of comfort

• Can help optimizing energy

Just PLAY with it!

PLAY-R

New design possibilities

Horizontal spread in narrow spaces

Hallways

Blends in perfectly

while supplying air

efficiently

• High tolerance to velocity and temperature variations

• Not affected by angle of air entering diffuser

• High Induction Rate

• Great for limited space in the ceiling

• Choice of 5 Concave Element colors

NEX - Reliability

PLAY - Flexibility• High tolerance to velocity and temperature variations

• Not affected by angle of air entering diffuser

• High Induction Rate

• Great for limited space in the ceiling

• Choice of 5 Concave Element colors

• Optimize Comfort and Energy

• Only diffuser allowing for full horizontal adjustment

• Easy to install, easy to use

• New design possibilities

• Save money on first service call

NEX - Reliability

PERFAIR plenums with Top or Side connexions

PLAY - Flexibility• High tolerance to velocity and temperature variations

• Not affected by angle of air entering diffuser

• High Induction Rate

• Great for limited space in the ceiling

• Choice of 5 Concave Element colors

• Optimize Comfort and Energy

• Only diffuser allowing for full horizontal adjustment

• Easy to install, easy to use

• New design possibilities

• Save money on first service call

Suitable for all types of ceilings (Lay-in, Drywall, Open)

NEX - Reliability

Both can easily replace diffusers in existing buildings

You now have the option!

effectiv-hvac.com

NEX and PLAY Innovative Solutions