16.06.2014www.hi-as.no Side 1

Key figures

Founded 1999

14 employees

More than 25 years

experience

Turnover 2013

75mill NOK

1200m2 Dusavik base-

Stavanger

16.06.2014www.hi-as.no Side 2

Our organisation

16.06.2014www.hi-as.no Side 3

Terje

Håland

Arvid

Eie

Reidun

Bakke

Hege

Nilsskog

Henning

Andersen

Øistein

Kolnes

Svein Inge

Eggebø

Martin

Haualand

Terje

Sjursen

Morten

Bjørkelund

Kjell

Vignes

Finn

Kjerpeseth

Ingrid

Torkelsen

Erling

Reilstad

What we offer

Sales» HI-AS is doing sales and marketing on quality from recognized

manufacturer with distribution network around the globe.

Engineering support» Our team consist of qualified engineers which can offer assistance for

applications as well as solutions.

Service» We offer our customers service including installation, commission,

repair and maintenance for delivered equipment.

Training» We can offer full training, either that been limited to a safe operation

or full service and repair capabilities for the products.

16.06.2014www.hi-as.no Side 4

Our product segments

Primary measurement Instruments » Pressure & Temperature» Level & Flow

Instrument/Piping Valves and Manifolds» Low & High pressure (6´000 – 150´000 PSI)» Top side & Sub-sea

Fire & Gas field equipment» Gas detectors for Point, Line of sight and Acoustic» Flame detectors based on

UV, UV/IR, IR or IR3 even with CCTV

16.06.2014www.hi-as.no Side 5

Field Instrumentation

16.06.2014www.hi-as.no Side 6

Level and Flow

Instruments

Pressure and Temperature

Switches

Differential Pressure Gauges

Press.- and Temp. Gauges

Valves and Manifolds

Flow Indicators

Level Glas

Temperature Instruments

Coriolis Flow meterGE Rheonik

Ultrasonic In-Line &Clamp-on Flow metersGE Panametric

Our partners

Valves

16.06.2014www.hi-as.no Side 7

Høytrykks ventiler,

fitting og tubing

Instrument ventiler og

Dobbel Block & Bleed

Spreng blikkContinental Disc Corp

Prosess Kontroll VentilerGE Masoneilan

SikkerhetsventilerGE Consolidated

Hydrauliske kontroll ventiler

Luftbehandling Pneumatiske kontroll ventiler

Our partners

16.06.2014www.hi-as.no Side 8

IR Point gas detector

IR Line gas - and

flame detectors

Manual Call Points, Sounders

Speakers, Beacons, Heat Det.

Gas detectors for HC, H2

H2S CO2 etc. & Systems

Laser line gas detectors for

HC,H2S,CO2, Amonia etc.

Fire & Gas Field Equipment

Our partners

Frame agreements

16.06.2014www.hi-as.no Side 9

16.06.2014www.hi-as.no Side 10

Simple level Switches

» Mechanic

» Electronic

• Capacitive, Ultrasonic, Thermal

dispersion

Level transmitters

» Mechanical

» Electronic

Flow transmitter for gas/air

» Thermal conductivity

16.06.2014www.hi-as.no Side 11

Radar Level Transmitter» Not affected by media variables eg.

dielectrics, pressure, temp, steam, and

density

» Designed for 430 bar/ 430° C

» Top or Interface measurement

» Saturated steam 155 bar@ +345 C

» ATEX EEx ia / EExd(ia)

» Probe devided into sections

» Certified for use in SIL3 circuits

» PACTware/AMS/Fieldbus/Profibus

16.06.2014www.hi-as.no Side 12

Last GWR innovation» New model 706 transmitter (2013)

» Echo curves on the display

» AMS comm port. provides echo curves to

control room

» ATEX Ex ia IIC T4/ Exd(ia) IIC T6

» Lloyds & SIL3 approvals

» PACTware/AMS/Fieldbus/Profibus

16.06.2014www.hi-as.no Side 13

Combined Level Measurement

» ”GWR & Magnetic Level gauge”

» ATEX Eex ia / Eex d (ia)

» 430 bar/430o C

» Not affected by process changes

» Hart/Fieldbus/PACTware/FDT

» Easy installation/configuration

16.06.2014www.hi-as.no Side 14

Level Glass

» Transparent & reflex type

Several material selections

Pressure up to 10000 PSI (690 bar)

Backlight (EEx me, LED type)

Magnetic type with LED rail

4-20mA or switch output

» In acc.to NORSOK I-001 & TR 3032

16.06.2014www.hi-as.no Side 15

Sight flow indicators

» In-line or weld pad ”windows”

» Different materials

» Rotor or flap indicators

» High pressure ratings on request (1500 lbs)

» Glass size from ½”-16”

» Flanged, threaded or welded connection

16.06.2014www.hi-as.no Side 16

Clamp- on & In-Line ultrasonic flow meters

» For liquied or gas

» Portable or fixed installation

» Can be delivered for use in Safe Area

or in Hazardeous area

GE Sensing

Flare gas references : Snøhvit, Gyda, Ula, Eldfisk, Kårstø, Petrojarl

Banf, Norne, Skangass Risavik

> Transmitter for safe area or hazardous areas

> Velocity : 0,03 – 120 m/sec

> Fiscal measurement

> Volume & mass flow measurement

Flare gas measurement :

GE Sensing

Hazardous area

Flare gas references : Skarv, Snøhvit, Gyda, Ula, Eldfisk, Kårstø, Petrojarl

Banf, Norne, Skangass Risavik

16.06.2014www.hi-as.no Side 18

Coriolis mass meters» Large measuring range

• 0,5 g/min – 25 ton/min

» Process conditions

• 900Bar/-200°C to +400°C

» Outputs

• Pulse/4-20mA/Hart/RS232/RS485

» Controllers

• None-Ex, EEx ia & EEx de (ia)

• For control room or field mounting

More than 22,000 meters in operations

GE Sensing

16.06.2014www.hi-as.no Side 20

Pressure-temp. switches

» House material, 316ss or aluminium

» Wetted parts : 316ss, Al or monel

» Process press : -980mBar – 540Bar

» Process temp : -40°C / +300°C

» EEx d, EEx ed or Eexi

» Maritime approvals

16.06.2014www.hi-as.no Side 21

Differential pressure gauges

» High static pressure (6000 PSI)

» Low differential pressure (20mbar)

» Aluminum or 316ss wetted parts

Pitot tube flow meters

Pulsation dampeners

16.06.2014www.hi-as.no Side 22

Temperature sensors(PT-100/PT-1000)

Multipoint measurements

Bi-metal thermometer (TMI 100)

Temperature transmitters

» 4-20mA/Hart/Fieldbus

Thermo wells

16.06.2014www.hi-as.no Side 23

Pressure & temperature Gauges

» Direct- or panel mounting

» Different materials available

» Chemical seal

• High viscosity application

• High temperature

» ”Vibragauge™”

• Designed for applications with high

pulsation/vibration. No glycerin

Fluorescent

scale

16.06.2014www.hi-as.no Side 24

Fluorescent scale

Fluorescent

scale

16.06.2014www.hi-as.no Side 25

Consolidated

Pressure Relief Valves

» Dimensions ½”- 12”

» ANSI 150 lbs-2500 lbs

» Temperature range -232 °C to +815°C

» Alloy and carbon steel materials/NORSOK M-650

16.06.2014www.hi-as.no Side 26

Masoneilan

Process Control Valves

» Dimensions 1”- 48”

» Pressure rating 150 lbs – 2500 lbs

» 316sst,Monel,Hasteloy, Duplex..

» -----------------------------------------------------------

» Masoneilan valve positioner SVI II ESD

» Partial Stroke Test Device/SIL3

» Universal design for on/off valves

16.06.2014www.hi-as.no Side 27

» Rupture Disc

» Size from ¼” to 44”

» Cracking pressure from 0,1–5000 Bar

» Temperature to 540°C

» Holders for ANSI & DIN Flanges

» Option with El.signal and Vacuum Protection

» A long list of materials available.

» 316SS, Monel, inconel, Hastelloy, Tantalium

16.06.2014www.hi-as.no Side 28

16.06.2014www.hi-as.no Side 29

16.06.2014www.hi-as.no Side 30

Hydraulic Control Valves

» Pilot and Solenoid Operated

» Exd, EExme or Exi Cert.

» 2/2, 3/2, 4/2, 5/2 valves

» Sizes DN2 – DN80

» 316ss material

» Up to 690 Bar / 400lt/min

16.06.2014www.hi-as.no Side 31

Pneumatic Control Valves

» Pilot or Solenoid Operated

» Exd, EExme or Exi Certified

» 22, 32, 52 and 52 style

» Size ¼” – ½”

» Material in 316SS

» Up to 10 Bar

16.06.2014www.hi-as.no Side 32

Pneumatic Filter Regulator

» Regulator and/or Filter

» 316L to NACE MR01-75

» 1/4”, 3/8”, 1/2”, 3/4”, 1” & 2”

» Manuelle/ Automatisk Drain

» High Pressure regulators

• Up to 220 Bar

16.06.2014www.hi-as.no Side 33

High Pressure Products, <150 000PSI

» Tubing, fittings and adapters, 1/8” to 1”

» Needle Valves

» Check – Safety Head and Relief Valves

» Used on Liquid, gas and Hydrogen applications

» Manufacture to Nace MR-01-75

16.06.2014www.hi-as.no Side 34

Valves

» BSP & NPT 1/4“ - 1/2“ 10‘000 psi

» Medium Pressure 1/4“ - 1“ 20‘000 psi

» High Pressure 1/4“ - 9/16“ 30‘000 psi

» High pressure 1/4“ - 9/16“ 60‘000 psi

16.06.2014www.hi-as.no Side 35

Valves & Manifolds

» To NACE MR-01-75

» Material in 316 or exotic

» Needle & Ball Valves to 1”

» 2-way to 5-way Manifolds

16.06.2014www.hi-as.no Side 36

Dobbel Block & Bleed Valves:Applications:

» Pressure Isolation

» Injection / Sampling

» Drain

» Level/ flow measurement

» Flow Lines

16.06.2014www.hi-as.no Side 37

Dobbel Block & Bleed Manifold

» Firesafe to A-607 & BS6755 part 2

» 3 Valves in size of 1

» Size from 1/2” – 16”

» Reduced or Full bore

» Class 150# til 2500#

16.06.2014www.hi-as.no Side 38

Subsea Valves

» Gate/Ball/Needle Valves as DBB style

» ROV & ”Diver” operating – 15K

» Needle Valves 10 – 25mm bore

» ½ Turn Gate Valves, also Actuated

» Single & double barrier Ball Valves

» Rotary Gate Valve

SUBSEA VALVE

16.06.2014www.hi-as.no Side 39

Elastomer free Subsea Valves

» Ball Valves

» ROV & ”Diver” operating

» Double barrier, including double isolation

» ½’’ Bore

» PR2 qualified 690 Bar

» Temperature range: -29° to 121° C

» Patented seal solution

16.06.2014d:\presentasjoner\hi-as.ppt Side 40

SharpEye Flame Detectors» UV-, UV/IR, IR og IR3

» Exd, Exde, EExia & Non-Ex certified

» 316ss, painted aluminium and plastic enclosure

» Relay, 4-20mA, HART and RS485 outputs

» Field of View up to 100º

» Range – 1x1 sq. ft. gasoline fire up to 200 feet/65m

» Combined IR3 flame detector for Gasoline & Hydrogen

» Marine Type Approved by DNV

» SIL 2 Approved by TUV in Germany

16.06.2014d:\presentasjoner\hi-as.ppt Side 41

SharpEye 40/40

Flame Detector» 316ss enclosure & bracket

» Built in Self-Test

» Very low weight, 2,8 Kg and low power, 3,8W

» 4-20mA, Relay, RS485 & HART output

» 95º Vertical & 100º Horizontal view

» Heated optic to avoid icing and condensation

» Combined IR3 flame detector for Gasoline & Hydrogen fire

» Range - 1x1 sq. ft. gasoline fire up to 200 feet/65m

» SIL 2 Approved by TUV in Germany

DNV Marine

Approved

with bracket

References: Gudrun, Valemon, Knarr, Mongstad, Skarv, Ula, Snorre A & B, BANFF, Varg, Norne, Åsgard A

16.06.2014www.hi-as.no Side 42

CCTV Flame detector

IR3 flame detector part

» Field of View- 90» Range - 1x1 sq. ft. gasoline fire

up to 200 ft./60 meter

» 4-20mA, HART or relay outputs

Live color video image» Range - 1x1 sq. ft. gasoline fire up to 100 ft./30 meter

» Field of View- 90(Hor.)x 65(Vert.)

» NTSC or PAL video output

16.06.2014d:\presentasjoner\hi-as.ppt Side 43

CCTV Configuration

Spectrex CCTV/IR3 Det.

F&G Control System CCTV System

PAL/NTSC

PAL/NTSC

PAL/NTSC

4-20mA

4-20mA

Video Signal

16.06.2014www.hi-as.no Side 44

SafEye Xenon 700 and 900(HC)

Line Gas Detectors for HC» Heated optic

» 7-200 meter path length

» Flash source

» 3-color LED indicator

» Imune against solar radiation

» 4-20mA, HART & RS485 outputs

» 316L Enclosure

» Integrated Exe termination compartment

» EExia Hand-Held or PC for alignment

» SIL 2 approved

16.06.2014www.hi-as.no Side 45

ELDS™

ENHANCED LASER DIODE SPECTROSCOPY

» 316ss enclosure

» Heated optic to avoid icing and condensation

» Path length from 0,5m up to 200 m

» Detector both Flammable and/or Toxic gasses

» Typical gasses: Methane, Propane, H2S, CO2..

» Range: 0-1LELm(CH4), 0-100 PPMm(H2S)

» 4-20mA/HART output(2 outputs on DUAL det.)

» Built in SimuGas™ remote functional check

» Remains in full operation with up to 95%

obscuration

16.06.2014www.hi-as.no Side 46

GD-10P and GD-10PE IR Point Gas Detector

» The benchmark for combustible gas detection

» 15 years warranty IR sources - solid state optics

» EExde Certified

» 4-20mA & HART output

» Fast response 5s or 1s(T50=0,7s)

» 316ss enclosure

16.06.2014d:\presentasjoner\hi-as.ppt Side 47

Acoustic Gas Leak detector» The gas cloud do not need to reach the

detector

» Detect small gas leakages up to 12m away(0,1Kg/sec)

» Built-In Acoustic Self-test

» Analogue 4-20mA & HART Output

» Senssonic™- integrated acoustic self-test for failsafe operation

» SIL 2 Approved

» EExd(e) or EExi certified

• OBSERVER-H: EExd/ EExde

• SURVEYOR: EExia

16.06.2014d:\presentasjoner\hi-as.ppt Side 48

Gas detectors for flammable & Toxic gasses» Delivered with pre-calibrated sensors

» Typical sensors: O2, H2S, NH3, H2 etc.

» Display & LEDs for status indication

» Built in event log

» 4-20mA, HART, Relay output

» SIL 2 Approved

» 316ss, Aluminium or plastic housing

» Exd, Exi or Non-Ex certified

16.06.2014www.hi-as.no Side 49

F&G Alarm Devices

» Manual Alarm Call Points

» Alarm Beacons & Status lights

» Rate Compensated Heat Detector

» GRP, 316ss or Aluminium housing

16.06.2014d:\presentasjoner\hi-as.ppt Side 50

Alarm Horn & Speakers» Alarm Horn < 118dBA

» Speakers < 25W

» GRP, 316ss or Aluminium housing

» EExd, EExde or EExi certified

» ATEX, UL, GOST, IECEx Approved