Going Beyond Advance Going Beyond Advance Framing!Framing!
Joining Forces for Tomorrows Construction Joining Forces for Tomorrows Construction PracticesPractices
BUILDERSASSOCIATION
Presented By: Paul G Johnson P.E.
A SPECIAL THANKSA SPECIAL THANKSTO OUR SPONSORSTO OUR SPONSORS
Truss Manufacturers of Texas Truss Manufacturers of Texas
(TMAT) (TMAT) MiTek IndustriesMiTek Industries Intelligent Building Systems (ITW)Intelligent Building Systems (ITW) Eagle MetalEagle Metal Simpson Strong TieSimpson Strong Tie
Why Go Beyond Advance Why Go Beyond Advance Framing?Framing?
Both the builders and home owners can benefit Both the builders and home owners can benefit from advance or new framing techniques. The from advance or new framing techniques. The proposal are structurally sound and come at a proposal are structurally sound and come at a lower cost of materials and labor while lower cost of materials and labor while increasing the R-value of the structure.increasing the R-value of the structure.
““Fully implementing advance framing techniques Fully implementing advance framing techniques can result in materials cost savings of about $500 can result in materials cost savings of about $500 or $1000 (for a 1,200- and 2,400 sq-ft house or $1000 (for a 1,200- and 2,400 sq-ft house respectively), labor savings of between 3 and 5 respectively), labor savings of between 3 and 5 percent and annual heating and cooling savings percent and annual heating and cooling savings of up to 5 percent”of up to 5 percent”
(Department of Energy, United States of America, (Department of Energy, United States of America, Technical Fact Sheet)Technical Fact Sheet)
Goal of this MeetingGoal of this Meeting
Present code accepted framing Present code accepted framing practices which will meet tomorrows practices which will meet tomorrows energy efficiency requirements.energy efficiency requirements.
Provide and open forum for all parties Provide and open forum for all parties to voice their ideas and concerns.to voice their ideas and concerns.
Develop friendships among all trades of Develop friendships among all trades of construction; construction;
WE ARE IN THIS WE ARE IN THIS TOGETHER!TOGETHER!
Welcome to Chapter 11Welcome to Chapter 11
Residential Law - January 1, 2012
Where is the Benefit Found?
Check out
“EnergyCodes.Gov”
Look for: “REScheck”
Softpedia-static
Discussion ItemsDiscussion Items
Roof Framing Roof Framing Wall Framing Wall Framing Floor FramingFloor Framing Miscellaneous Framing IdeasMiscellaneous Framing Ideas Green Building TopicsGreen Building Topics Things to Think AboutThings to Think About
Roof FramingRoof Framing Raised heel conditions for required insulationRaised heel conditions for required insulation Minimal bearing wallsMinimal bearing walls Attic usageAttic usage
HVACHVAC Conditioned Duct ChaseConditioned Duct Chase RoomRoom Water HeatersWater Heaters
Cantilever conditions to eliminate beams and Cantilever conditions to eliminate beams and headersheaders
Gable trusses as structural to eliminate headersGable trusses as structural to eliminate headers 8’ O.C. roof trusses to minimize bearing 8’ O.C. roof trusses to minimize bearing
requirementsrequirements
ROOF FRAMINGROOF FRAMINGNew Energy Requirement: New Energy Requirement:
R30R30
Insulation Requirements at the roof and exterior wall Insulation Requirements at the roof and exterior wall connection for Texas. Non-compacted R30connection for Texas. Non-compacted R30
Pink Fiberglass Batts= 9 ½” Blown Fiberglass=12 ¼” Pink Fiberglass Batts= 9 ½” Blown Fiberglass=12 ¼” Cellulose 8 3/8”Cellulose 8 3/8”
Conventional Frame Detail Truss Detail
Courtesy of Eagle Metal
Conventional FramingConventional Framing
ProsPros Better insulation valuesBetter insulation values
ConsCons 2x6 standard rafter on walls 2x6 standard rafter on walls
no longer works.no longer works. Not all built up system are Not all built up system are
covered by code nailing. covered by code nailing. “Horizontal Thrust” issues. “Horizontal Thrust” issues. Engineering may be required.Engineering may be required.
Lateral support (IRC R802.8) Lateral support (IRC R802.8) required which exceed 5 to 1 required which exceed 5 to 1 ratio.ratio.
Additional exterior material; Additional exterior material; brick or siding required.brick or siding required.
Additional Cost of Framing Additional Cost of Framing and materialand material
Raised Rafter FramingPitch=6/12 2x6 Rafter Height= 10 1/8”
2x10 or 2x12 Rafter With Raised CeilingCourtesy of Eagle Metal
Component FramingComponent Framing
ProsPros Better insulation valuesBetter insulation values Directly built into componentsDirectly built into components Horizontal Thrust Accounted Horizontal Thrust Accounted
for.for.
ConsCons Additional costAdditional cost Additional exterior material; Additional exterior material;
brick or siding required.brick or siding required.
Raised Common Heel with Slider
Raised Sloped Ceiling Component
Courtesy of Eagle Metal
Roof and Ceiling Roof and Ceiling FramingFraming
Use an absolute minimal number of bearing walls Use an absolute minimal number of bearing walls and eliminate headers.and eliminate headers.
Clear Span All Walls With ComponentsConventional FrameWith Minimal Bearing
Courtesy of Eagle Metal
Header Requirements IRC
Can a portion of a wall be considered bearing while the remainder portion is non-bearing?
Is a braced wall line a bearing wall?
Roof FramingRoof Framing
Utilize Attic Space Utilize Attic Space HVAC LocationHVAC LocationConditioned Duct ChaseConditioned Duct ChaseAdditional RoomsAdditional RoomsWater heater locationWater heater location
Roof Framing Roof Framing HVAC in AtticHVAC in Attic
Courtesy of Mitek
Condition Space or Not Conditioned?
Roof Framing Roof Framing HVAC & Duct Chase in AtticHVAC & Duct Chase in Attic
Courtesy of Mitek
Conditioned Chase in theAttic or Below the Attic?
Roof FramingRoof FramingUse of Attic for Additional Use of Attic for Additional
Living SpaceLiving Space
Courtesy of Mitek
Why Waste the Attic Space?
Inverted ValleyTruss Forms Wall
Roof FramingCode Living Space
Requirements
Building Code Basics: Residential; Stephen A Van Note
Roof FramingRoof FramingUse Attic to hold Water Use Attic to hold Water
HeatersHeaters
Courtesy of Mitek
Roof FramingRoof FramingPro-Cons of Attic Space Pro-Cons of Attic Space
UsageUsage Utilize wasted space for mechanical Utilize wasted space for mechanical
or living area. Go GREENor living area. Go GREEN Centralize mechanical and water to Centralize mechanical and water to
minimize run lengths. GO GREENminimize run lengths. GO GREEN Conditioned Duct chase may reduce Conditioned Duct chase may reduce
unit size and cost. Go GREENunit size and cost. Go GREEN Solar water heating system in close Solar water heating system in close
proximity of the storage unit. GO proximity of the storage unit. GO GREENGREEN
Roof FramingRoof FramingConsider Eliminating Wall Consider Eliminating Wall
HeadersHeaders
Roof FramingRoof FramingConsider using Trusses or Consider using Trusses or
Framing in Cantilever Framing in Cantilever ConditionsConditions
Roof FramingRoof FramingConsider Cantilevering your Consider Cantilevering your design to eliminate beamsdesign to eliminate beams
Consider using Consider using common sensecommon sense
Not all Not all cantilevers will cantilevers will eliminate eliminate beamsbeams
Some of the ideas but not Some of the ideas but not all of themall of them
Attic Area Added
Cantilever Roof
Missed using Gable for load transfer
Roof FramingRoof FramingPro-Cons of Minimal Pro-Cons of Minimal
BearingBearing Using interior walls as bearing and Using interior walls as bearing and
cantilevering over exterior walls allows for cantilevering over exterior walls allows for more insulationmore insulation
Cantilever over porch eliminates beams Cantilever over porch eliminates beams Interior wall may contain headers but they will Interior wall may contain headers but they will
not need insulation not need insulation Careful; To long of cantilever could cause Careful; To long of cantilever could cause
deflection concerns (long term creep factor)deflection concerns (long term creep factor) Existing gable roofs sections should be utilized Existing gable roofs sections should be utilized
as headers.as headers. How does wind analysis play into this How does wind analysis play into this
concept???concept???
Roof FramingRoof FramingStretching Typical FramingStretching Typical Framing
Can we apply Commercial Framing
to Residential Framing?
Roof FramingRoof FramingStretching Typical FramingStretching Typical Framing
Courtesy of Mitek
Roof Framing Re-CapRoof Framing Re-Cap Raised heel conditions are the future.Raised heel conditions are the future. Utilize the wasted area in the attic for Utilize the wasted area in the attic for
either mechanical equipment or either mechanical equipment or additional living area.additional living area.
Model your roof around advance framing Model your roof around advance framing techniques.techniques.
Integrate your roof and ceiling design Integrate your roof and ceiling design with your bearing and non bearing walls.with your bearing and non bearing walls.
Expand your standard conception of how Expand your standard conception of how a roof should be framed.a roof should be framed.
Wall FramingWall Framing Corners and TEE’sCorners and TEE’s Stacked FramingStacked Framing
24” o.c. stud spacing24” o.c. stud spacing Single top plate bearing wallsSingle top plate bearing walls Load Path developmentLoad Path development
New Age Headers / Old Age FramingNew Age Headers / Old Age Framing Box HeadersBox Headers LVL short or single plyLVL short or single ply Single ply conventionalSingle ply conventional ComponentComponent
Bracing SolutionsBracing Solutions Moment FrameMoment Frame Plated WallPlated Wall
Wall FramingWall FramingCorners and TEE’sCorners and TEE’s
Slide 23A
Slide 23B
Insulation, Insulation, Insulation
Currently code approved
Easy to insulateDrywall clips may be
requiredNo more freezing pipes
IRC 2009 Fig R602.3(2)
Wall FramingWall Framing24” O.C. Stud Design24” O.C. Stud Design
• Interior non load bearing at 24” is acceptable down to a 2x3Interior non load bearing at 24” is acceptable down to a 2x3• 2x4 Exterior is acceptable at 24” if supporting a Roof 2x4 Exterior is acceptable at 24” if supporting a Roof OROR
Floor system separately.Floor system separately.
Wall FramingWall Framing2+ Story with 24” O.C. Stud 2+ Story with 24” O.C. Stud
DesignDesign
Courtesy of Mitek
A habitable attic couldbe added for spans up to 32’0”
Wall supports one set of floors
Wall supports roof only
Wall FramingWall FramingSingle Top Plate designSingle Top Plate design
Section R602.3.2. Section R602.3.2. Allows for a Single Allows for a Single Top Plate for Top Plate for bearing walls bearing walls under the under the “Exception” rule“Exception” rule
Wall FramingWall FramingSingle Top Plate designSingle Top Plate design
Section R602.5 States that interior non-Section R602.5 States that interior non-load bearing walls shall contain at least a load bearing walls shall contain at least a single top plate.single top plate.
FootnoteFootnoteBack Pocket InfoBack Pocket Info
Previous exception Previous exception referenced fire referenced fire blocking per blocking per section R602 which section R602 which sends you to sends you to R302.11 and allows R302.11 and allows Batts or blankets of Batts or blankets of mineral or glass mineral or glass fiber to be used as fiber to be used as fire stopping. fire stopping.
Wall FramingWall FramingSingle top plate designSingle top plate design
Remember your tall wall fire blocking.
In this case the first story must be 2x6 studs at 24” o.c. or 2x4” at 16” o.c.
Single top plates used when the rafters, joist or
components are centered with the studs or within
1”
Courtesy of Mitek
Wall Framing HeadersWall Framing HeadersBox HeadersBox Headers
IRC 2009 Code
Wall FramingWall FramingEngineered Wood ProductsEngineered Wood Products
Single Ply LVL Header
LVL 3 ½” x 4” header
Wall FramingWall FramingConventional MaterialConventional Material
Single 2x header with flat 2x
Wall FramingWall FramingComponent HeaderComponent Header
Loose 4x2 Header or Built up Window Component
Wall FramingWall FramingHeader ClipsHeader Clips
Taken from Department of Energy, Technical Fact Sheet
Simpson HH Header Clip
Wall FramingWall FramingSingle Stud Usage Around Single Stud Usage Around
OpeningsOpenings Code Section R602.3: Code Section R602.3:
Defines studs as Defines studs as being continuous being continuous from sole plate to a from sole plate to a support at the top, support at the top, with the exception of with the exception of jack studs, trimmers jack studs, trimmers studs and cripple studs and cripple studs at openings studs at openings that comply with that comply with R502.5(1) & (2)R502.5(1) & (2)
Wall FramingWall FramingSingle Stud with Header Single Stud with Header
Clip (cont)Clip (cont)
Table reflects the acceptable practices of using a single stud Table reflects the acceptable practices of using a single stud with a header clip, without any additional calculations.with a header clip, without any additional calculations.
Wall FramingWall FramingNarrow Wall Bracing Narrow Wall Bracing
Narrow wall bracing issues are not only for garages. Window framing may require such details which limit insulation.
Wall FramingWall FramingBracing SolutionsBracing Solutions
Courtesy of Universal Forest Products
Wall FramingWall FramingEntire Wall as Plated Entire Wall as Plated
Component?Component?
With plated walls wind connections could be incorporated
Wall Framing Wall Framing Re-CapRe-Cap
Think insulation, insulation, and more Think insulation, insulation, and more insulationinsulation
Look at your T’s and CornersLook at your T’s and Corners Look for more cost effective headers Look for more cost effective headers
with a payback in energy savings as wellwith a payback in energy savings as well How much wood fiber can you remove?? How much wood fiber can you remove?? Consider your window location along Consider your window location along
with a 24” stud layout. with a 24” stud layout. Make room for bracing at the cornersMake room for bracing at the corners
Floor FramingFloor Framing
Rim Board load capacitiesRim Board load capacities EWPEWP ConventionalConventional
Girder Floor TrussGirder Floor Truss Girder Knee-WallGirder Knee-Wall Top chord bearing trussTop chord bearing truss Cantilever porchesCantilever porches
Floor FramingFloor FramingCode Acceptance of Floor Space Code Acceptance of Floor Space
SupportSupportFigure Figure R502.2R502.2
IRC 2009IRC 2009
For write up For write up referrefer
to section to section
R502.6-7R502.6-7
Floor FramingFloor FramingRim Board or Header?Rim Board or Header?
EWP rim board with no header below
Why Not Both
Floor FramingFloor FramingConventional Rim or Conventional Rim or
Headers?Headers?
Boise BC Rim Board (Tech Note Rim-4)
Floor FramingFloor FramingGirder TrussGirder Truss
Courtesy of Mitek
Floor FramingFloor FramingTop Chord Bearing Floor Top Chord Bearing Floor
TrussesTrusses
Courtesy of Mitek
Floor FramingFloor FramingCantilever ConditionsCantilever Conditions
Courtesy of Mitek
Floor FramingFloor FramingCantilever ConditionsCantilever Conditions
Floor & Roof FramingFloor & Roof FramingCantilever ConditionsCantilever Conditions
Remember “Load Path” Think top-down KEY CONCEPT
Component – “Load Path” Trusses
Conventional – “Load Path” Braces and posts
Conventional – “Load Path” Conventional
Framing
Miscellaneous Framing Miscellaneous Framing IdeasIdeas
Tall wall with top chord bearing Tall wall with top chord bearing trusstruss
Extended Bottom chordExtended Bottom chord
Miscellaneous Framing Miscellaneous Framing IdeasIdeas
Tall Wall FramingTall Wall Framing
Courtesy of Mitek
Miscellaneous Framing Miscellaneous Framing IdeasIdeas
Second Story Tall Wall Second Story Tall Wall
Courtesy of Mitek
Green Building TopicsGreen Building Topics Consider finger joint lumber (note grade) Consider finger joint lumber (note grade)
from recycled or waste lumber.from recycled or waste lumber. Compare actual material required versus Compare actual material required versus
today's standard framing methods.today's standard framing methods. Look at your job site waste factors.Look at your job site waste factors. Components factory built and 3-D Components factory built and 3-D
designed; most recycle lumber down to designed; most recycle lumber down to 8” lengths. 8” lengths.
Consider the length of the overhang as Consider the length of the overhang as well as the depth of the heel.well as the depth of the heel.
Things to Think AboutThings to Think About Not all items shown may be good for your Not all items shown may be good for your
project.project. Current Framers are not well trained in advance Current Framers are not well trained in advance
framing.framing. A few of the items may require special A few of the items may require special
engineering.engineering. Value engineer your project at the design stage.Value engineer your project at the design stage. Consider 4’0” clear corners for bracingConsider 4’0” clear corners for bracing Would you consider a double exterior wall with Would you consider a double exterior wall with
an air space between?an air space between? Are today's conventional framing practices the Are today's conventional framing practices the
way of the future or are components?way of the future or are components?
Thank You for AttendingThank You for Attending
We hope that we were able to We hope that we were able to provide you with some innovated provide you with some innovated ideas which will help you reach your ideas which will help you reach your new energy requirements, provide new energy requirements, provide cost savings and at the same time be cost savings and at the same time be green by general design.green by general design.