FCSNaonalWorkshop EnvironmentalApplicaonsofJetGroung ... · RangeofResults Single fluid Double...

Post on 26-Aug-2020

1 views 0 download

Transcript of FCSNaonalWorkshop EnvironmentalApplicaonsofJetGroung ... · RangeofResults Single fluid Double...

FCS  Na'onal  Workshop    

Environmental  Applica'ons  of  Jet  Grou'ng    

Montreal,  Quebec  April  27,  2016  

 Stephen  Custeau,  P.Eng.  ,MBA  MATCON  Environmental  Ltd.  

 

Outline  

 

-­‐  History  of  Jet  Grou2ng    -­‐  How  the  technology  works    -­‐   Applica2ons  -­‐  Case  Histories  for  environmental  applica2ons  

 Recochem  Port  Coquitlam    New  Westminster  Pier    John  Hart  Dam  (cut  off  /  ground  improvement)  

   

History  of  Jet  Grou2ng  

-­‐ Japan  (CCP)  70’s  

-­‐   Europe  late  70’s    -­‐  NA  –  middle  80’s  

How  it  works  STEP  1  :  DRILLING

STEP  3:      PULL  UP  THE      ROTATING  JET  

STEP  2    START  JETTING  WITH    W/C  GROUT  MIX  FROM  THE  BOTTOM  

RESULT:  ROUND  COLUMN    CONSISTING  OF  WATER/CEMENT  MIX  AND  INSITU  SOIL  

Resul2ng  Column  

Geometry  

Environmental  Containment    

Jet  Grout  Parameters  

Flexibility  

Range  of  Results  

Single fluid Double Fluid Triple Fluid

Gravel 0.6-1.2 1.0-1.6 2.0-3.0 10-30 2,500-15,000Sandy Gravel 0.5-1.0 0.9-1.8 1.5-3.0 8-20 2,500-10,000

Silty Clay 0.5-1.0 0.8-1.5 1.2-2.8 5-15 2,500-7,500Clayly Silt 0.4-0.6 0.7-1.0 1.0-1.5 2-8 1,000-5,000

Clay 0.4-0.8 0.6-1.2 0.8-1.2 1-6 500-5,000

E (Mpa)Type of Soil Diameter (m) UCS (Mpa)

Hydraulic  Conduc2vity  =  10-­‐6  to  10-­‐9  m/s  Depending  on  soil  condi2ons  and  grout    Mix  (with  or  w/o  bentonite).      

QA/QC  at  Grout  Plant  

QC-­‐  Monitoring  and  recording  jedng  

QC-­‐  Monitoring  and  recording  jedng  

QA/QC-­‐  Monitoring  /  Recording  

Verifica2on    

-­‐  Coring    -­‐   Permeability  tests  (direct-­‐indirect)  -­‐   Cross/holes,  tomography  -­‐   Calipers  -­‐   Load  test  in  case  of  piles  

Typical  JG  Projects  • Shoring/Cut-­‐Off/Underpinning:                North  Vancouver  -­‐  Parcel  5                Richmond  –  The  Mandarin                  False  Creek-­‐  Olympic  Village                New  Westminster-­‐  Mul2use  Facility  Centre  • Cut-­‐Off  (environmental)                              Recochem,  Port  Coquitlam  

 New  Westminster  Pier                              John  Hart  Dam                          Zeballos  Lake  •   Soil  Improvement  for  Sejlement  Control              New  Westminster-­‐  Clarkson  &  Sixth  •   Piling                Richmond  –  Paloma  Parkade  • Shals                North  Vancouver-­‐  Esplanade  &  St.  George                IONA  Treatment  Plant  (3  phases)                                                      

Recochem,  Port  Coquitlam  

Port  Coquitlam  

Port  Coquitlam  

Port  Coquitlam  

Port  Coquitlam  

K=  10-­‐7  cm/sec;  10-­‐9  m/sec  

New  Westminster  Pier      

Loca2on  

The  Op2ons  

The  Site  

The  Site  

Mapping  the  Columns  

John  Hart  Dam  John  Hart  Dam    

Loca2on      

Field  Test    

Produc2on  Area  

Field  Test  Area  

Field  Test    

Drilling  Procedures    

Pre-­‐drilling  and    PVC  installa2on  

Field  Test  Results    

Very  Congested  Site!  

Spoil/Reflow  storage  tanks  

Bentonite  mud  storage  tanks  

Grout  mix  plant  

 Spoil/Reflow  Management    

 Spoil/Reflow  Management    

Real  Time  Control    

QA/QC    

As  Built    

Ques2ons?    

Stephen  Custeau,  P.Eng.,  MBA    

MATCON  Environmental  Ltd.