Façades Beyond Glass

Post on 24-Mar-2022

13 views 0 download

Transcript of Façades Beyond Glass

Façades Beyond Glass

Timothy SOEBROTOMeinhardt Façade Technology

11th July 2019

2

PART OF A GLOBAL NETWORK

Meinhardt group, a global multi-disciplinary engineering

consultancy with over 4,500 staff in 45 offices worldwide.

Our global presence and international experience allow us

to best service our projects across regions. Unique to MLS is our

ability to offer a fully integrated and seamless design in close

coordination with engineering teams, project management

and planning departments, or be contracted independently.

EUROPELondon

MIDDLE EAST

& NORTH AFRICA

(MENA)DohaDubaiKuwait CityManamaMuscatRiyadh

AUSTRALIAAdelaideBrisbaneMelbourneSydney

ASIABangkokBeijingCambodiaChennaiDanangGurgaonHanoiHo Chi Minh CityHong KongJakartaKarachiKuala LumpurLahoreMacauManilaNoidaSeoulShanghaiShenzhenSingaporeTianjin

3

4

FAÇADES BEYOND GLASS

5

6

7

8

FAÇADES BEYOND GLASS

9

- Transparency

- Visibility

10

BACK GROUND

11

12

INTRODUCTION or BACKGROUND

EXPLORING Alternative Materials

EXAMINING the compatibility of the

materials and building requirements

EXECUTING the best methods

FAÇADES BEYOND GLASS

13

FAÇADES BEYOND GLASS

EXPLORING Alternative Materials

Aluminium Panel or Aluminium Composite Panel

Stone Cladding

Terracotta

Glass Reinforced Polyester

Large Size Ceramic Tiles

14

FAÇADES BEYOND GLASS

ALUMINIUM PANEL OR

ALUMINIUM COMPOSITE PANEL

15

ALUMINIUM PANEL

16

ALUMINIUM COMPOSITE PANEL

17

ALUMINIUM PANEL

18

ALUMINIUM PANEL

19

ALUMINIUM PANEL

20

ALUMINIUM PANEL

21

The ADDRESS DOWNTOWN HOTEL , DUBAIFire Incident, New Year Eve - 2015

22

THE ADDRESS DOWNTOWN

HOTEL, DUBAI, UAE

Building type: 63-storey hotel (5-star)

Fire Event: 31st December 2015

Fire Duration: 4 hours

Fire Caused: Electric Short Circuit at

level 14 to 15

Fire Damage:

- 14 people suffered minor injuries

- 1 people suffered moderate injuries

- Hotel closed for renovation.

- 320 US$ claim to insurance

Criticism was levelled towards the high amount of cladding

implemented into the building's design; it was reported that this

cladding may have contributed to the fire's spread.

23

The TORCH TOWER, DUBAI MARINA1st Fire Incident, 21st February 2015

2nd Fire Incident, 4th August 2017

24

The Telegraph News:

The external cladding on the building was

blamed for the rapid spread of the 2015 fire

THE TORCH TOWER, DUBAI

MARINA, UAE

1st fire incident

Building type: 84-storey residential

Fire Event: 21st February 2015

Fire Duration: N/A

Fire Caused: Grilled at Balconies at

level 50

Fire Damage:

- 7 people suffered due to smoke

inhalation.

- External cladding were burned from

lv. 50 to roof.

- 101 of 757 units apartment is

inhabitable and have to be

renovated.

25

THE TORCH TOWER, DUBAI

MARINA, UAE

2nd fire incident

Building type: 84-storey residential

Fire Event: 4th August 2017

Fire Duration: N/A

Fire Caused: N/A

Fire Damage:

- No injuries

- More than 40 floor are burned

26

HOW TO MITIGATE THE FIRE• MATERIAL – FIRE RATED MATERIAL

• CORRECT FAÇADE DESIGN

31

FAÇADES BEYOND GLASS

STONE CLADDING

32

STONE CLADDING

33

STONE CLADDING

34

STONE CLADDING

35

STONE CLADDING

36

STONE CLADDING

37

Granite

Marble

Limestone

Sandstone

Slate

STONE CLADDING

38

STONE CLADDING

39

STONE CLADDING

40

STONE CLADDING

41

STONE CLADDING

42

Crushing Test

Flexural Strength Test

Thermal Movement

Petrographic Examination

Compressive Test

Breaking Load at Hole

STONE CLADDING - TESTING

43

STONE CLADDING - DEFECT

44

STONE CLADDING - FAILURE

45

FAÇADES BEYOND GLASS

TERRACOTTA

46

TERRACOTTA

47

TERRACOTTA

48

TERRACOTTA

49

TERRACOTTA

50

TERRACOTTA

51

TERRACOTTA

52

TERRACOTTA

53

TERRACOTTA

54

TERRACOTTA

55

TERRACOTTA

56

FAÇADES BEYOND GLASS

GLASS REINFORCED POLYESTER

57

GLASS REINFORCED POLYESTER

58

GLASS REINFORCED POLYESTER

59

GLASS REINFORCED POLYESTER

60

GLASS REINFORCED POLYESTER

61

GLASS REINFORCED POLYESTER

62

GLASS REINFORCED POLYESTER

63

GLASS REINFORCED POLYESTER

64

GLASS REINFORCED POLYESTER

65

GLASS REINFORCED POLYESTER

66

GLASS REINFORCED POLYESTER

67

FAÇADES BEYOND GLASS

LARGE SIZE CERAMIC TILES

68

CERAMIC TILES

69

CERAMIC TILES

70

CERAMIC TILES

STUDY CASE

HOUSE of ROMAN, Jakarta

Client: Roman Ceramic

Architect: Anggara Architeam

Facade Consultant: Meinhardt Façade

Façade Contractor: Polareka Fasadindo

Façade: Ceramic Tiles by Roman,

QUADRA

Fixings: Fischer

71

CERAMIC TILES

72

CERAMIC TILES

73

CERAMIC TILES

74

CERAMIC TILES

75

CERAMIC TILES

76

CERAMIC TILES

77

CERAMIC TILES

78

Timothy SOEBROTOAssociate Director

Meinhardt Façade Technology

timothy.s@mfacade.com

FAÇADES BEYOND GLASS

79

FAÇADES BEYOND GLASS

80

FAÇADES BEYOND GLASS

81

FAÇADES BEYOND GLASS

82

FAÇADES BEYOND GLASS

83

FAÇADES BEYOND GLASS

84

FAÇADES BEYOND GLASS

85

FAÇADES BEYOND GLASS

86

FAÇADES BEYOND GLASS

87

Timothy SOEBROTOAssociate Director

Meinhardt Façade Technology

timothy.s@mfacade.com

FAÇADES BEYOND GLASS

Copyright © Meinhardt Group 2017. All rights reserved. No part of this publication may be reproduced by any means, whether graphically, electronically,

mechanically or otherwise howsoever, including without limitation photocopying and recording on magnetic tape, or included in any information store and/or

retrieval system without prior permission of Meinhardt Group.

Thank You