Experiments towards the Efficient Trapping of Francium by Seth Aubin Parity Violation in Francium...

Post on 21-Dec-2015

219 views 0 download

Tags:

Transcript of Experiments towards the Efficient Trapping of Francium by Seth Aubin Parity Violation in Francium...

Experiments towards the Efficient Trapping of Francium

by Seth Aubin

Parity Violation in Francium Group

Students:Eduardo GomezJoshua M. Grossman

Professors:Luis A. OrozcoGene D. Sprouse

A Brief History of Francium at Stony Brook

1991-94: Construction of 1st production and trapping apparatus.

1995: Produced and Trapped Francium in a MOT.

1996-2000: Laser spectroscopy of Francium (8S1/2, 7P1/2,7D5/2,7D3/2, hyperfine anomaly).

2000-2002: construction of new production and trapping apparatus.

10,000 atom Fr MOT

New Apparatus for Producing and Trapping Francium

Objective: Trap 106 Fr atoms

Parity Non-Conservation experiments

Nuclear Anapole measurements

Strategy:

• Increase Production

• Optimize Optical Trapping efficiency

• Improve Neutralizer efficiency

Schematic of New Apparatus

Improved Production

0

2

4

6

8

10

12

14

16

0 500 1000 1500 2000 2500 3000t (s)

Fr

pro

du

cti

on

ra

te (

mill

ion

Fr/

s)

phase transition

beam blocked

16O, 18O, 19F ~100 MeVFr+ ions

Au, Pt target

Improved Fr+ ion extraction New target design

Heated tungsten rod

Optical Trapping Efficiency1. Capture Velocity of MOT

Idea: • Accelerate MOT atoms with laser.

• Measure at what velocity atoms cannot be recaptured by MOT.

b. Velocity Calibration:a. Description

atom cloud

on resonance laser push

0

5

10

15

20

25

0 50 100 150 200 250 300

push time (microseconds)

fin

al v

elo

city

(m

/s

c. Capture Velocity (lower bound):

~18 m/s

MOT

1 mm

Displaced MOT

(External B-field)Laser push

1 mm

2. Number of Bounces (Nbounces)

Atoms rethermalize with cell walls on each bounce.

NMOTNbounces.

Nbounces is determined by exit holes, quality of dry-film coating.

Dry-Film (SC-77) test:

780 nm laser probe

Rb atomic beam

shutter

fast detector

Cell with coating (Rb curing)

0.74

0.76

0.78

0.8

0.82

0.84

0.86

0 10 20 30 40 50time (ms)

flu

ore

sc

en

ce

(a

. u.)

Decay Time = 6.6 ms

Monte-Carlo simulations decay time of 5.2 ms (~100 bounces)

Cell without coating

0.0375

0.04

0.0425

0.045

0 3 6 9 12 15 18 21time (ms)

fluo

resc

ence

(a.

u.)

decay time < 1 ms

Comparison of Neutralizer Materials (at 5 KeV)

~ 300 Celsius

Conclusion

New apparatus for trapping 106 Fr atoms.

Increased Fr production by a factor of 15.

Studied neutralization process.

Probes of capture velocity and coating quality.

Capture velocity of at least 18 m/s.

Just converted apparatus to Francium.