Post on 31-Dec-2015
description
ELEKTRAL A.S.
ASSEMBLING & MOUNTING ThruScan
You need 15 minutes for assembling!...
Get User’s Manual
PLS. Download from our web-site: www.elektral.com.tr
You receive 2 boxes for each metal detector:
• Main Control & Display Unit
• Side Panels (Left&Right)
1
ELEKTRAL A.S.
ASSEMBLING & MOUNTING ThruScan
You need 15 minutes for assembling!...
Get User’s Manual
PLS. Download from our web-site: www.elektral.com.tr
When you open the boxes:• Main Control & Display Unit
• Back Fixing Unit
• Left Side Panel
• Right Side Panel
2
ELEKTRAL A.S.
ASSEMBLING & MOUNTING ThruScan
You need 15 minutes for assembling!...
Get User’s Manual
PLS. Download from our web-site: www.elektral.com.tr
3
4Assembling Back Fixing Unit
Other side
ELEKTRAL A.S.
ASSEMBLING & MOUNTING ThruScan
You need 15 minutes for assembling!...
Get User’s Manual
PLS. Download from our web-site: www.elektral.com.tr
5
Screw up the rear cover of the Main Control & Display Unit.
ELEKTRAL A.S.
ASSEMBLING & MOUNTING ThruScan
You need 15 minutes for assembling!...
Get User’s Manual
PLS. Download from our web-site: www.elektral.com.tr
6
7
For the sockets:
ThruScan is designed to prevent false connector/socket connection.
Left Panel – female D-Sub 25
Mains Socket - SRC- D-Sub 9
Right Panel – male D-Sub 25
ELEKTRAL A.S.
ASSEMBLING & MOUNTING ThruScan
You need 15 minutes for assembling!...
Get User’s Manual
PLS. Download from our web-site: www.elektral.com.tr
8 9
Screw down the Main Control & Display Unit.
Fix strongly to the side panels.
ELEKTRAL A.S.
ASSEMBLING & MOUNTING ThruScan
You need 15 minutes for assembling!...
Get User’s Manual
PLS. Download from our web-site: www.elektral.com.tr
1011
Fasten the black blind taps
Lift up your ThruScan
ELEKTRAL A.S.
ASSEMBLING & MOUNTING ThruScan
You need 15 minutes for assembling!...
Get User’s Manual
PLS. Download from our web-site: www.elektral.com.tr
12
Plug in the connectors.
ELEKTRAL A.S.
ASSEMBLING & MOUNTING ThruScan
You need 15 minutes for assembling!...
Get User’s Manual
PLS. Download from our web-site: www.elektral.com.tr
13
14
Left Side Panel Connectors
Right Side Panel Connector Mains Connector (from left
side panel)
Impossible to make mistake…
ELEKTRAL A.S.
ASSEMBLING & MOUNTING ThruScan
You need 15 minutes for assembling!...
Get User’s Manual
PLS. Download from our web-site: www.elektral.com.tr
15
Close the rear cover of Main Display & Control Unit.
ELEKTRAL A.S.
ASSEMBLING & MOUNTING ThruScan
Adjust the distance between side panels to 76 cms.
You need 15 minutes for assembling!...
Get User’s Manual
PLS. Download from our web-site: www.elektral.com.tr
16
ELEKTRAL A.S.
ASSEMBLING & MOUNTING ThruScan
You need 15 minutes for assembling!...
Get User’s Manual
PLS. Download from our web-site: www.elektral.com.tr
17 18
Mark the positions of side panel holders.
ELEKTRAL A.S.
ASSEMBLING & MOUNTING ThruScan
You need 15 minutes for assembling!...
Get User’s Manual
PLS. Download from our web-site: www.elektral.com.tr
19 20
21 22
Drill & Fix the side panel holders to the ground – stable conditions.
ELEKTRAL A.S.
ASSEMBLING & MOUNTING ThruScan
You need 15 minutes for assembling!...
Get User’s Manual
PLS. Download from our web-site: www.elektral.com.tr
23
24
25
Put your ThruScan into the side panel holders inside and screw the bolts.
ELEKTRAL A.S.
CONTROL PANEL OF ThruScan Metal Detectors
LCD DISPLAY 4*20
OFF BUTTON ON BUTTON BATTERY INDICATOR
PACING LIGHT
INDICATOR
LED VU
DISPLAY
ALARM LOCATORRUN BUTTON
SEL UP DOWN
TOUCH PADS
ELEKTRAL A.S.
MULTI POINT INDICATOR LIGHTS
ENTRANCE- Traffic Lights
Led illuminated Warning Displays on Zones
ELEKTRAL A.S.
RELAY CONTACT OUTPUTS
RELAY CONTACT OUTPUTS
SYNC & REMOTE CONTROL OUTPUTS
Provides to control CCTV Cameras, Turnstiles, Gates…etc.
For tandem operation or
SRC- Scada Remote Control
ELEKTRAL A.S.
PROGRAMMING & SETUP
Normal Operating Screen(When you swich on – the screen)
IN OUT01978 00027
SECURITY LEVEL 03
ENTER PASSWORD[0---]
To enter the program menu
Press
SECURITY LEVEL
LEVEL 02
If the correct password is entered display will
change to:
SECURITY LEVELPASSWORD ERROR
If the password is incorrect:
ELEKTRAL A.S.
SECURITY LEVEL & SENSITIVITY LEVEL ADJUSTMENTS
SECURITY LEVEL
LEVEL 02ThruScan s9 has 10 seperate SECURITY LEVELS
ThruScan sX has 20 seperate SECURITY LEVELS
SECURITY LEVEL SENSITIVITY ADJUSTMENT
Security Level (NC) NILECJ – Level 2 (factory fixed)
Security Level 1 010
Security Level 2 020
Security Level 3 030
Security Level 4 050
Security Level 5 100
Security Level 6 140
Security Level 7 180
Security Level 8 220
Security Level 9 230
ThruScan s9
It is possible to adjust a total of 246 sensitivity levels from security level 000 (highest sensitivity) to 245 (lowest sensitivity)
SECURITY LEVEL
LEVEL [02]=20
ELEKTRAL A.S.
SECURITY LEVEL & SENSITIVITY LEVEL ADJUSTMENTS
SECURITY LEVEL
LEVEL 02
ThruScan sXSECURITY LEVEL SENSITIVITY ADJUSTMENT
Security Level (NC) NILECJ – Level 2(factory fixed)
Security Level 1 010
Security Level 2 020Security Level 3 030Security Level 4 040Security Level 5 050Security Level 6 060Security Level 7 070Security Level 8 080Security Level 9 090Security Level 10 100Security Level 11 110
Security Level 12Security Level 13Security Level 14Security Level 15Security Level 16Security Level 17Security Level 18Security Level AD
120140160180200220240030 – Auto Designation/AD
SECURITY LEVEL
LEVEL [02]=20
SECURITY LEVEL
LEVEL [15]=180
ELEKTRAL A.S.
SECURITY LEVEL
LEVEL [15]=180
You can make fine tunning here: 185Between 000(highest sebsitivity) – 245(lowest sensitivity)
IN OUT01978 00027
SECURITY LEVEL 03
ENTER PASSWORD[0---]
SECURITY LEVEL
LEVEL 02
SECURITY LEVEL
LEVEL [02]
SECURITY LEVEL
LEVEL [15]
ELEKTRAL A.S.
SECURITY LEVEL
LEVEL [15]=180
SECURITY LEVEL
LEVEL [15]=181
SECURITY LEVEL
LEVEL [15]=185
Normal Operating Mode
Other Menus
ELEKTRAL A.S.
SECURITY LEVEL & SENSITIVITY LEVEL,ZONE ADJUSTMENTS for ThruScan sX
The sensitivity levels of zones can be adjusted separately.
The sensitivity level of zone 2 in which there would more likely be keys, cell phones, belts etc. can be decreased while the other zones’ can be increased.
IN OUT01978 00027
SECURITY LEVEL 03
* 5 SECURITY LEVEL
LEVEL [02]=20
* 1SECURITY LEVEL
INDIVIDUAL ZONE SENSLEVEL 02
SECURITY LEVELINDIVIDUAL ZONE SENS
LEVEL [02]
SECURITY LEVELINDIVIDUAL ZONE SENS
LEVEL [02]ZONE=[01]
ZONE=2 ZONE=3
ZONE [01]=20
Normal Operating Mode
Other Menus
ELEKTRAL A.S.
AUTO DESIGNATION AND AUTOMATIC SENSITIVITY ASSIGN for ThruScan sX
This menu is to help the user to decide and to assign the required sensitivity level very rapidly.
IN OUT01978 00027
SECURITY LEVEL 03
* 5 SECURITY LEVEL
LEVEL [02]=20* 2
USED FOR AUTODESIGNATE OF
SECURITY LEVEL TOCONTINUE PRESS SEL
AUTO DESIGNATE MODE
WHEN TRAFFIC LED ISGREEN, ENTER
METAL OBJECT THENPRESS SEL 3/1
WHEN TRAFFIC LED ISGREEN, ENTER
METAL OBJECT THENPRESS SEL 3/2
WHEN TRAFFIC LED ISGREEN, ENTER
METAL OBJECT THENPRESS SEL 3/3
DESIGNATE-DETECTMODALL ZONES 00 ZONE 01
[00]
01
00
ELEKTRAL A.S.
AUTO DESIGNATE MODETO DESIGNATE PRESS SEL
LEVEL [AD]=53
DESIGNATE-DETECTMODALL ZONES 00 ZONE 01
[53]
01
AUTO DESIGNATE MODE IN OUT01978 00027
SECURITY LEVEL 03
AUTO DESIGNATE MODETO DESIGNATE PRESS SEL
ZONE [01]
SELECT THE ZONE
AUTO DESIGNATE MODETO DESIGNATE PRESS SEL
ZONE [01]=53
AUTO DESIGNATION MODE - continue
ELEKTRAL A.S.
ALARM VOLUME ADJUSTMENT
IN OUT01978 00027
SECURITY LEVEL 03
* 5 SECURITY LEVEL
LEVEL [02]=20* 3 ALARM VOLUME
0<=>10
ALARM VOLUME0<=>10
VOLUME=05
ALARM VOLUME0<=>10
VOLUME=10
ThruScan s9-sX has 10 separate alarm volume levels, 1 quietest – 10 loudest – 00 Mute
If you want different tones, pls mention with your order. It has 10 different tones in the menu.
ELEKTRAL A.S.
ALARM COUNTER
IN OUT01978 00027
SECURITY LEVEL 03
* 5 SECURITY LEVEL
LEVEL [02]=20* 4 ALARM COUNTER
00012
ALARM COUNTER00012
RESET Y <=> N N
ALARM COUNTER00000
ALARM COUNTER00012
RESET Y <=> N Y
NORMALOPERATINGMODE
MENU
ELEKTRAL A.S.
IN – OUT COUNTER (TRAFFIC COUNT)
IN OUT01978 00027
SECURITY LEVEL 03
* 5 SECURITY LEVEL
LEVEL [02]=20* 5 IN>-COUNTER-<OUT
99999………………….…01977
NORMALOPERATINGMODE
MENU
IN>-COUNTER-<OUT99999………………….…01977
ACTIVE =0000 – Do not reset01 – Reset In Count02 – Reset Out Count03 – Reset Both Counters
ELEKTRAL A.S.
FACTORY SETTINGS
IN OUT01978 00027
SECURITY LEVEL 03
* 5 SECURITY LEVEL
LEVEL [02]=20* 6 FACTORY SETTINGS
Y<==>N
NORMALOPERATINGMODE
MENU
Y – FACTORY RESETN – DO NOT RESET
FACTORY SETTINGSY<==>N
ACTIVE =N
ThruScan s9-sX can be returned to factory setting by this menu.
ELEKTRAL A.S.
LANGUAGE SELECTION
IN OUT01978 00027
SECURITY LEVEL 03
* 5 SECURITY LEVEL
LEVEL [02]=20* 7 LANGUAGE
ENGLISH
NORMALOPERATINGMODE
MENU
ENGLISHDEUTSCHTURKCEESPANOL
ThruScan s9-sX can be operated in 4 languages- EN-DE-SPA-TR
LANGUAGEENGLISH
<===================>
ELEKTRAL A.S.
COUNTER VISIBILITY
IN OUT01978 00027
SECURITY LEVEL 03
* 5 SECURITY LEVEL
LEVEL [02]=20* 8 COUNTER VISIBILITY
Y<==>N
NORMALOPERATINGMODE
MENU
N – DISPLAY OFFY – DISPLAY ON
ThruScan s9-sx’ Normal Operating Mode-Menu Displaycan be inhibited.
COUNTER VISIBILITYY<==>N
ACTIVE =Y
IN OUT ***** *****
SECURITY LEVEL 03
ELEKTRAL A.S.
ENVIRONMENT NOISE LEVEL
IN OUT01978 00027
SECURITY LEVEL 03
* 5 SECURITY LEVEL
LEVEL [02]=20* 9 ENVIRONMENTAL
NOISE LEVEL
NORMALOPERATINGMODE
MENU
This menu is prepared to measure the electromagnetic noise level in the environment in which the ThruScan was placed and help the user with the sensitivity level assignment.
ENVIRONMENTALNOISE LEVELNOISE = 003
ELEKTRAL A.S.
NEW PASSWORD
IN OUT01978 00027
SECURITY LEVEL 03
* 5 SECURITY LEVEL
LEVEL [02]=20* 10 NEW PASSWORD
[ ]
NORMALOPERATINGMODE
MENU
You can change your 4 digit pin-code as follows: Let’s make password 1978
NEW PASSWORD[ 0 * * * ]
123……….89
NEW PASSWORD[ 1 * * * ]
123……….89
NEW PASSWORD[ 1 9 7 8 ]