Post on 18-Nov-2020
Vestibule
Open Space 1
Open Space 2
Control Room Stock Room
Fitting Room 1
Kitchen
Closet 1
Men's Restroom
Vestibule
Fitting Room 2
Hallway
Private Room
Closet 2
Women's Restroom
Storage Room
+/- 150'
+/- 123'
+/- 10'
+/- 149'
+/- 13'
+/- 26'+/- 110'
+/- 9'
15'-5"
4'-11"
6'-4"
119'-4"
48'-9" 10'-2"6'-5" 62'-2"
132'-5"
14'-11"
8'-2"24'
17'-1"64'-2"7'-8"4'-5"10'-11"15'-4"
14'
15'-7"8'-2"
5'-10"
4' 15'4'-11"
11'-5" 8'6'-4"
11'-6" 7'-8"5'
13'
22'-6"27'-10"
14'-10"
12'-8"
25'-4"55'-10"
7'-8"
9'-4"
112'-7"
121'-8"
FRONT
REAR
Site M
ap
Unit #
28
400 N. Tampa St. Suite 2210Tampa, FL 33602
Phone: (866) 657-2545IDPlans.com
Plans produced by:ID Plans
Eastgate Plaza
Revis
ions
Prep
ared 7
/11/
2019
0' 7' 14' 21'
3504 Cragmont DriveTampa, FL 33619
VALIDUS GROUP PROPERTIES
Site map is for general use and purposes only. ID Plansdoes not guarantee the accuracy or validity of provided
information. Measurements are not intended to bearchitecturally valid for construction purposes or accepted
as replacement for documents, drawings, or mediaintending or claiming to be structurally accurate, such assite blueprints. The property owner has and reserves the
right and responsibility to verify, change, or alter theprovided information at any time for any reason.
MAIN FLOOR1
© 2019
Unit # 28 Ground Floor +/- 18,697 SF
Width +/- 123'
Depth +/- 150'
Gross square footage was measured on-site and
adheres to BOMA standards
© Copyright 2019 1Plans produced by: ID Plans, t: 866-657-2545
Virtual Tour Link
Electrical Information:
Breaker Panel: 1Service Type: 120/208Panel Type: NLABPanel Number: AY-305013Manufacturer: General ElectricAmps: 225Location: Stock Room
Breaker Panel: 2Service Type: 120/208Panel Type: NLABPanel Number: AY-305013Manufacturer: General ElectricAmps: 225Location: Stock Room
Breaker Panel: 3Service Type: 120/208Panel Type: NLABPanel Number: AY-305013Manufacturer: General ElectricAmps: 225Location: Stock Room
Exterior Disconnect Information:Amps: N/APanel Type: N/APanel Number: N/AManufacturer: N/ALocation: No Exterior Disconnect
Ceiling Information:Height from Floor to Ceiling:Front: 13’ Back: 9’ 2”Floor to Bottom of Deck:Front: 17’ 10” Back: 16’ 11”Floor to Bottom of Joist:Front: 16’ 3” Back: 15’ 2”
Fire Information:Riser Location: Control RoomSprinkler Heads Present: YesNumber of Sprinkler Heads: 145Fire Alarm Control Panel Present: YesBrand: Silent KnightModel: 4000Location: Control Room
Water Heater Information:Gallons: 19.9Water Line (in): 1”Manufacturer: RheemModel: 81VP20SSerial: RH0103279665 Location: Closet 2
Backflow Information:Number: 0Size: N/ALocation: No Backflow Preventor Present
HVAC Information:
Unit: 1Manufacturer: CARRIERModel: 50TC-D16A2A5A0A0A0Serial: 0716P03769Tonnage: 15Year: 2016
Unit: 2Manufacturer: CARRIERModel: 50TC-D16A2A5A0A0A0Serial: 0716P03770Tonnage: 15Year: 2016
Unit: 3Manufacturer: CARRIERModel: 50TC-D16A2A5A0A0A0Serial: 4514P10512Tonnage: 15Year: 2014
Unit: 4Manufacturer: CARRIERModel: 50TCQD12A2A5A0A0A0Serial: 4715P76985Tonnage: 10Year: 2015
Unit # 286929 N. 9th AvenuePensacola, FL 32504
Unisex Restroom
© Copyright 2019 2
Eastgate Plaza, Unit # 28
Plans produced by: ID Plans, t: 866-657-2545
Space Profile for Unit: # 28 Area: 18,697 sq ft
Address 6929 N. 9th AvenuePensacola, FL 32504
400 N. Tampa St. Suite 2210Tampa, FL 33602
© Copyright 2019 3
Eastgate Plaza, Unit # 28
Plans produced by: ID Plans, t: 866-657-2545
Storefront Elevation
© Copyright 2019 4
Eastgate Plaza, Unit # 28
Plans produced by: ID Plans, t: 866-657-2545
Ground Floor
THIS
FLO
ORP
LAN
IS P
ROVI
DED
WIT
HO
UT
WAR
RAN
TY O
F AN
Y KI
ND
. SEN
SOPI
A D
ISCL
AIM
S AN
Y W
ARRA
NTY
INCL
UD
ING
, WIT
HO
UT
LIM
ITAT
ION
, SAT
ISFA
CTO
RY Q
UAL
ITY
OR
ACCU
RACY
OF
DIM
ENSI
ON
S.
1
Window Plan
72”
99”
Window A = 99”H X 11”WWindow B = 22”H X 11”W
39”
36”
84”
36”
84”
36”
36”22”
99”
36”
36”22”
99”
36”
36”22”
99”
36”
36”22”
99”
36”
36”22”
99”
36”
36”22”
99”
36”
36”22”
99”
36”
36”22”
99”
36”
36”22”
99”
36”
36”22”
99”
36”
36”22”
99”
36”
36”22”
A F H J L N P R T V X Z B1 B D E G I K M O Q S U W Y A1 C1
C
A F H J L N P R T V X Z B1 B D E G I K M O Q S U W Y A1 C1
C
© Copyright 2019 5
Eastgate Plaza, Unit # 28
Plans produced by: ID Plans, t: 866-657-2545
Window Plan
A
B D E
C
© Copyright 2019 6
Eastgate Plaza, Unit # 28
Plans produced by: ID Plans, t: 866-657-2545
Window Plan
F H J L N P
G I K M O Q
© Copyright 2019 7
Eastgate Plaza, Unit # 28
Plans produced by: ID Plans, t: 866-657-2545
Window Plan
R T V X Z B1
S U W Y A1 C1
© Copyright 2019 8
Eastgate Plaza, Unit # 28
Plans produced by: ID Plans, t: 866-657-2545
Prepared 7/11/2019
Address 6929 N. 9th AvenuePensacola, FL 32504
Please See Meter & HVAC Information on the Next Page
28
1 2
4
3
1
© Copyright 2019 9
Eastgate Plaza, Unit # 28
Plans produced by: ID Plans, t: 866-657-2545
Prepared 5/09/2019
Address 1130 Warm Springs HighwayManchester, GA 31816
Reference Meter
Electric 3248132
Gas None
Water Meter Removed
#
#
1
Met
er In
form
atio
n
Meter & HVAC Information
Unit Space Manufacturer Model Ton Serial Year
1 28 CARRIER 50TC-D16A2A5A0A0A0 15 0716P03769 2016
2 28 CARRIER 50TC-D16A2A5A0A0A0 15 0716P03770 2016
3 28 CARRIER 50TC-D16A2A5A0A0A0 15 4514P10512 2014
4 28 CARRIER 50TCQD12A2A5A0A0A0 10 4715P76985 2015
HVA
C U
nits
&
Info
rmat
ion
Note: Electric Meter Inactive
© Copyright 2019 10
Eastgate Plaza, Unit # 28
Plans produced by: ID Plans, t: 866-657-2545
Legend
Disclaimer: All items may not show on feature pages.
Breaker Panel
Circular Column
Appliance Outlet
Fire Alarm
Drinking Fountain
Door
Double Hung Door
Electrical Outlet
Emergency Light
Exit Light
Tankless Water Heater
Step Down Transformer
Disconnect
Fire Extinguisher
Fire Alarm Pulldown
Glass Door
Handicap Handrail
Roof Hatch
HVAC Unit
Recessed Light
Staircase
Water Heater
Telephone Panel
Window Wall Opening
Maintenance Sink
Ceiling Fan w/ Light
Rectangular Column
Refrigerator
Roll-Up Door
Sink
Swing Door
Toilet
Can Light
Urinal
Thermostat
RJ 45
Window
Fire Sprinkler
Pocket Door
Track Lighting
2-Bulb Fluorescent Lighting
3-Bulb Fluorescent Lighting
4-Bulb Fluorescent Lighting
Ceiling Air Vent
Air Diffuser
Ceiling Fan w/o Light
Air Handler
Fire AlarmControl PanelFACP
© Copyright 2019 11
Eastgate Plaza, Unit # 28
Plans produced by: ID Plans, t: 866-657-2545
Detail PlanRear
Front
Joist
Girders
Ground Floor
THIS
FLO
ORP
LAN
IS P
ROVI
DED
WIT
HO
UT
WAR
RAN
TY O
F AN
Y KI
ND
. SEN
SOPI
A D
ISCL
AIM
S AN
Y W
ARRA
NTY
INCL
UD
ING
, WIT
HO
UT
LIM
ITAT
ION
, SAT
ISFA
CTO
RY Q
UAL
ITY
OR
ACCU
RACY
OF
DIM
ENSI
ON
S.
1
Unit # 28
© Copyright 2019 12
Eastgate Plaza, Unit # 28
Plans produced by: ID Plans, t: 866-657-2545
Reflected Ceiling Plan
Ceiling Specifications
Height from Floor to Ceiling Front: 13’ Back: 9’ 2”
Floor to Bottom of Deck: Front: 17’ 10” Back: 16’ 11”
Floor to Bottom of Joist Front: 16’ 3” Back: 15’ 2”
Notes:
Joist
Girders
Rear
Front
Ground Floor
THIS
FLO
ORP
LAN
IS P
ROVI
DED
WIT
HO
UT
WAR
RAN
TY O
F AN
Y KI
ND
. SEN
SOPI
A D
ISCL
AIM
S AN
Y W
ARRA
NTY
INCL
UD
ING
, WIT
HO
UT
LIM
ITAT
ION
, SAT
ISFA
CTO
RY Q
UAL
ITY
OR
ACCU
RACY
OF
DIM
ENSI
ON
S.
1
Acoustic Ceiling
Open Ceiling
Type Fixture Qty
2 Bulb Fluorescent Encased 34
Recessed Bulb 1
Can Bulb 2
Sprinkler Heads Present Qty
Yes 145
Ligh
ting
Fire
Info