Digital Pressure Analyzer MD80 - reseggas.comBelonging to MEASUREMENTS internal sensors Reading and...

Post on 29-Mar-2021

5 views 0 download

Transcript of Digital Pressure Analyzer MD80 - reseggas.comBelonging to MEASUREMENTS internal sensors Reading and...

Belonging to

MEASUREMENTS internal sensorsReading and direct tests up to 10 PaReading and direct tests up to 1000 mbarTemperature up to 100 ° CBarometric pressure

MEASUREMENTS external sensorsReading and direct tests up to 45 barTemperature up to 500 ° C

Pressure recorder in gas pipesRegistration of a networked pressure

SETTINGSSet time and dateSet technician dataEntry phonebook, customer data, even from memoryChange password o disabledEnable or disable of barometric pressureThe battery status read controlSelection of the graphic displayConnection settings with PCSet language: IT-EN-FR-ESSelecting the internal pressure max 10 PaSelecting the internal pressure max 500 mbarSelecting the external pressure transducer, 10/45 barSelecting the size of the test syringeSelecting thermometer: Internal -20+100 °CSelecting thermometer “2” : Esternal -50+1000 °CSelecting bluetooth or IR printer

PRINTERControl and printer start up

DATA TRANSMISSION & MEMORYBluetooth Data transmissionIR data transmissionCustomer store from micro SD to internal phonebookStored data transmission of the plants inspected,Deleting stored data

COMMUNICATION PORTS2 Thermocouple temperature type K ports1 Micro USB port for PC connection, battery charger1 Micro HDMI port for connecting accessories1 Micro SD CARD for storing data

INFORMATIONSProduct, serial number, revision expiration date, etc..Laws and decrees presentationDiameters and volume of the pipes

CONVERTERUnit of measure.

CALCULATORMathematic operations

Digital Pressure Analyzer MD80

UNI 7129 Less than 35 kW Tightness testUNI 11147 Pressure plant tightness testUNI 11137 Calculation of liter leak automaticUNI 11137 Calculation of liter leak manualUNI 11137 Tightness test for max. 18 dm^3 systemsUNI 11137 Valve tightness testaUNI 11137 Mechanical tightnessUNI 10738 Ventilation and change air in roomsUNI 10845 Depression test of chimneys draftUNI 10845 Pressure tightness of chimneys draftUNI 11528 6a species > of 35kW for external pipesUNI 11528 6a species > of 35kW for underground pipesUNI 11528 7a species > of 35kW for external pipesUNI 11528 7a species > of 35kW for underground pipes

Description of the TEST programs according to UNI

Multifunctional touchscreen

Power ON/OFF

100°C Temperature sensor

1000 mbar - Positive input

1000 mbar - Negative input

CONFORMITY

User Guide

Channel: Beinat gas solutions

Electric connections also available on

Registration Number

Stamp of the Dealer

In agreement with our continuous development policy, we reserve the right to modify our products without notice.

Purchase Date

Lo styling è della b & b design

BE-Rev - 18 03

Business - info@beinat.comHelp Desk - laboratorio@beinat.com

BEINAT S.r.l. Via Fatebenefratelli 122/C10077, S. Maurizio C/se (TO) - ITALYTel. 011.921.04.84 - Fax 011.921.14.77http:// www.beinat.com

INSURANCE.This device is insured by the SOCIETÀ REALE MUTUA for the PRODUCT’S GENERAL LIABILITY

up to a maximum of 1.500.000,00 EURO against damages caused by the device in case of failures in functioning.

WARRANTY.The warranty term is 3 years from manufacturing date, in agreement with the followingconditions. The components acknowledged as faulty will be replaced free of charge, excluding thereplacement of plastic or aluminium cases, bags, packing, batteries and technical reports.The device must arrive free of shipment charges to BEINAT S.r.L.. Defects caused by unauthorized personneltampering, incorrect installation and negligence resulting from phenomena outside normal functioning shall beexcluded from the warranty.The BEINAT S.r.L. company is not liable for possible damage, direct or indirect, to people, animals, or things;from product faults and from its enforced suspension of use.

MD80

Made in Italy