Design Matrix For Emergency Landslides · Instructions for Sizing Piles In the Field by...

Post on 07-Jul-2020

6 views 0 download

Transcript of Design Matrix For Emergency Landslides · Instructions for Sizing Piles In the Field by...

Design Matrix For Emergency Landslides

Joe CarteUnit Leader ‐Geotechnical Engineer 

The Problem: WV had over 

200Emergency 

Landslides that Originated from the March 3rd

Flooding Event 

32 Counties in March 3rd Declaration

Most of the 200 Slidesare in 5 Counties

FEMA Declarations this Year

Access Blocked to Homes =Emergency

Mr.  Wentz Showing his Best Side

Our  Geotechnical Unit had

2Weeks

to Provide25

Designsfor this

Emergency Declaration

Our Geotechnical Unit Mark Nettleton

GeotechnicalEngineer

Aaron WentzEngineering Geologist

George ChappellEngineering Geologist

Bob BarclayEngineeringGeologist

Ryan YoungGeotechnician

Our Unit is Busy with Our Regular Duties

We Design Repairs for Major Landslide/Rockfalls for all 10 Districts

We Write GeotechnicalReports for the WVDOH In‐House Design Section

We Review Consultants’Geotechnical Reports and Foundation Designs

Some of Our Regular Duties Include:

The Remainder of the Emergency 

Landslide Repairs were, and continue 

to be, Designed By the Districts 

and Consultants

And Our Unit ‐We are Now up to about 30 Emergency Landslide Designs  

Can We Drill the Slide Sites? NO!

Instrumentation? Out!

One Lane Width

3 Different Bedrock Depths

High, Medium, &, Low Groundwater

Levels 

Assumed Soil & Rock Parameters

So We looked at Several Typical Scenarios as Follows:

We Also Modeled

a 28 feet Road Width and 

Looked at the Different Rock 

Depths

Our Goals Was to Determine the Maximum Exposed Wall Height (Stick‐up) 

for 3 Common Pile Sizes (HP10x42, HP12x53, & HP14x73) in each Scenario

PSSLOPE Program ‐ Input Window

Simple Wedge Analysis

Pile Performance Ratio – Ok at FS= 1.25 

4 inches Deflection is OK for Rural Roads ‐ Service Limit State (FS=1.0)

The Stick‐Up Matrix Using 3 Pile Sizes for One & Two Lane Widths and Various  

Depths to Rock and 

GroundwaterLevels  

Instructions for Sizing Piles In the Field by ExperiencedWall Designers

• HP10x42 = 12 feet wall height• HP 12x53 = 14 feet wall height• HP 14x73 = 17 feet wall height

• If you see rock at the bottom of the wall location, then you can add 2 feet to each of these max stick‐upheights.

• If the hillside is steep below the wall location or you may lose some of the passive wedge, upsize the pile.

Example  Emergency Landslide

Slide LengthTie into Existing Walls

Exposed HeightQuantities

Notes

Write Up Sheet

The Sketch

Fill in The Blank Splice Detail

Title Page

Quantity Estimate

Sketch and Notes

Typical Details

Typical Wall Profile & More Details

Wale Details

Questions

Thank Youfrom theIn-house

GeotechnicalUnit