SCALE DATEAPPROVEDDRAWN

Stiwdio OwensEyarth BachLlanfair Dyffryn ClwydRuthinDenbighshireLL15 2EGhello@stiwdioowens.co.uk+44 (0)1824 544000

DRG. NO

TITLE

STATUS

Stiwdio Owens Landscape Architecture

REVISION

REV. NO. DESCRIPTION OF REVISION INITIALSDDMMYY

Bryn Coch lane, Mold CH7 1PS

YSGOLGLANRAFON

P ISSUED FOR PLANNING APPROVAL

FENCING DESIGN

YGM-STO-00-00-DR-L-0004

1:500@A1 GLO GLO 050520

P1.0

1. Drawing copyright of Stiwdio Owens Landscape Architecture.2. All information to be read in conjunction with relevant landscape drawings and specification.3. Only figured dimensions are to be used.4. All dimensions in millimetres unless otherwise noted.5. The Landscape Architect is to be notified of any discrepancies before proceeding.6. No liability accepted for amendments by others.7. Utilities - A safe system of work to HSE HSG47 Avoiding danger from underground services to

be followed by contractor to plan, detect, identify, mark services and employ safe excavation/ safe digging practices prior to works commencing.

8. Proposed planting locations to be reviewed following detail design of infrastructure requirements including easements for underground or above ground services, overhead power lines, highway safety and visibility splays and other infrastructure provisions, such as substations, refuse stores, lighting, signage and CCTV requirements.Indicative location from provided service plans. Alignments shown are not traced, have not been located via trial pits, and are extrapolated from service plans. Please refer to supplied service plans for full site information.

9. Drawing for the purpose of planning and not for construction.

Existing fence or wall

Proposed weldmesh (1.8m)

Propsoed weldmesh single gate (1.8x1.5m)

DRAWING NOTES

KEY

Proposed weldmesh (1.5m)

Propsoed bowtop fence (1.15m)

Propsoed vertical bar fence (1.2m)

Proposed weldmesh double gate (1.8x3.5m)

Proposed self closing bowtop gate (1.2x1.2m)

Proposed weldmesh single gate (1.5x1.2m)

Schedule - Fencing

Type Railing height Total length

Handrail 1.20 m 42 m

Chainlink 1.50 m 82 m

Timber close boarded 1.80 m 41 m

Bowtop 1.20 m 48 m

Weldmesh 1.50 m 33 m

Weldmesh 1.80 m 228 m

Vertical bar 1.20 m 117 m

Proposed weldmesh double gate (1.8x6.0m)

Proposed weldmesh double gate (1.5x3.0m)

Schedule - Gates

Type Height Width Count

Weldmesh single 1.50 m 1.20 m 1

Weldmesh single 1.50 m 1.50 m 1

Weldmesh single 1.80 m 1.50 m 5

Weldmesh double 1.50 m 3.00 m 1

Weldmesh double 1.80 m 3.50 m 2

Weldmesh double 1.80 m 6.00 m 1

Bowtop single 1.20 m 1.20 m 3

Propsoed timber close boarded fence (1.8m)

Proposed weldmesh (1.8m)

Propsoed vertical bar fence (1.2m)

Propsoed bowtop fence (1.15m)

Proposed self closing bowtop gate (1.2x1.2m)

Propsoed timber close boarded fence (1.8m)

Proposed weldmesh gate (1.8m)

Proposed weldmesh single gate (1.5x1.5m)

Propsoed chainlink fence (1.5m)

P1.0 AMENDED DROP OFF LAYOUT GLO120520