The importance of air quality: ISO standard
Experience gained over many years has enabled BEKO TECHNO-LOGIES to design ever more efficient, reliable and high-quality compressed air treatment systems. Every compressed air system is designed and built in line with the specific requirements of the customer, above all taking into account the ISO standards that go-vern the quality of the compressed air.There are three standards currently in force that refer directly to the quality (purity) and the analysis of compressed air:
ISO 8573 / ISO 12500 / ISO 7183
The one used most is ISO 8573. This standard defines the methods and tests to be used to determine the contaminants present in compressed air.
Classification of contaminants according to ISO 8573:• Solid particulate• Residual humidity• Residual oil (including vapour) content
The consequences of contaminants in compressed air
The consequences of the use of contaminated compressed air can range from faults in plants, limited production and shutdowns due to problems with the quality of the end product:
• Premature wear
• Rust and corrosion of equipment
• Instrumentation damage
• Imperfect painted surfaces
• Increase in the volume of waste
• Delivery of faulty products into the market
• Wear and corrosion of pipes
TO CHECK THE PERFORMANCE OF COM-PRESSED AIR PURIFICATION DEVICES
Service | BEKO TECHNOLOGIES
“The regular and continuous analysis of the quality of compressed air guarantees safety to the production processes, free from the risks of contamination”
53542_new air quality brochure.indd 2 18/03/2016 14:58
Food industry
Pharmaceutical industry
Electronics industry
When dealing with food, hygiene is the main requirement to guarantee the quality of fini-shed products. During production, the pneumatic processes and the transport of substan-ces require compressed air of absolute purity. For packaging, clean compressed air is indi-spensable for cleaning, for example when using compressed air to clean plastic bottles or containers. Our process technology provides for the tailor-made treatment of compressed air via the discharge of condensate, filtration and drying.
The most rigorous hygiene standards are applied in the production of pharmaceuticals. This obviously also applies to the compressed air that is used. This air must be absolutely free from oil so as not to contaminate sensitive products, for example in the production of pills: any dust is removed down-stream of the press with compressed air.BEKO TECHNOLOGIES offers personalised solutions to prepare oil-free process air safely.
In the electronics industry, compressed air is used in various ways: as a means of transport and cleaning, as energy support for compressed air tools. In any application, the compressed air requirements are high in terms of purity. With the components in the system combined to best effect, we guaran-tee an unbeatable treatment of the compressed air throughout the process. The METPOINT® OCV continuously measures the residual oil vapour content in the com-pressed air and makes that quality visible.
Service | BEKO TECHNOLOGIES
To establish the quality of air in line with ISO 8573-1 2010, the international standard for the classification of contaminants
ISO 8573-1 is the main document of the ISO 8573 series, as it spe-cifies the level of contamination allowed for every type of contami-nant in each cubic metre of compressed air. ISO 8573-1 lists the main contaminants such as solid particulate, water and oil (in the form of aerosol and vapour).
The maximum levels for every contaminant are shown separately in tabular form, but to make the document easier to understand, all three contaminants are combined.
Air quality classesSolid particulate, maximum number of particles per m3 PDP (pressure dew point)
°C Oil (including steam)(mg/m3)0.1 µm – 0.5 µm 0.5 µm – 1.0 µm 1.0 µm – 5.0 µm
0 Based on the specifications of the user or the equipment supplier and more stringent than class 1
1 ≤ 20.000 ≤ 400 ≤ 10 ≤ –70 ≤ 0.01
2 ≤ 400.000 ≤ 6.000 ≤ 100 ≤ –40 ≤ 0.1
3 – ≤ 90.000 ≤ 1.000 ≤ –20 ≤ 1
4 – – ≤ 10,000 ≤ +3 ≤ 5
5 – – ≤ 100,000 ≤ +7 > 5
6 – – – ≤ +10 –
Compressed air quality ISO 8573-1: 2010
3
53542_new air quality brochure.indd 3 18/03/2016 14:58
The quality of the air cannot be seen, but can be measured:Measurement systems and services from BEKO TECHNOLOGIESCompanies try to overcome considerable challenges during pro-duction: when the safety of products and processes depends on the quality of compressed air. It is necessary to guarantee treat-ment at the highest level and to establish air quality that is com-pliant with ISO 8573-1: 2010. BEKO TECHNOLOGIES not only produce systems for the treatment of compressed air but also of-fers a wide range of measuring instruments that monitor and re-cord data; this guarantees visible and certified safety of compres-sed air quality.
With innovative technology from BEKO TECHNOLOGIES for measuring the quality of compressed air, your system will beco-me more secure.
BEKO TECHNOLOGIES offer a service that enables you to measure all the parameters in real time, without having to purchase all the in-strumentation necessary to measure air quality to the ISO 8573 stan-dards. All of the measuring instruments used during the service are subject to a regular annual calibration to guarantee the efficiency and reliability of the measurements.
The METPOINT® OCV, whether mobile or fixed, is the leading me-asurement system in the world with TÜV certification for measu-ring the content of residual oil vapour in compressed air.
Service | BEKO TECHNOLOGIES
53542_new air quality brochure.indd 4 18/03/2016 14:58
Measurement of the quality of compressed air according to ISO 8573:
Solid particulate – residual humidity – residual oil (including vapour)
METPOINT® OCV - Residual oil va-pour content meterThe METPOINT® OCV with TÜV certification meets the measurement requirements for residual oil vapour and hydrocarbons according to the ISO 8573.1 standard for classes 1, 2, 3 and 4. METPOINT® OCV makes the purity of your compressed air visible
Certificate issued by TÜV NORTH
5
METPOINT® BDL Data logging for compressed air applications
PC 400 – Particle meter The high precision of the PC 400 particle counter measures particles from 0.1 µm and is therefore ideal for monitoring the quality of compressed air to class 1 (ISO 8573)
METPOINT® DPM – Pressure dew point meterThe fixed dew point meter shows
temperature, relative humidity and
pressure dew point (down to below
<-70 °C PDP) accurately, not just for
compressed air but also for other
gases
Service | BEKO TECHNOLOGIES
53542_new air quality brochure.indd 5 18/03/2016 14:58
C, G, F, S
F (optional)*
S
S
S
F (optional)*
F (optional)*
F (optional)*
F
G
F
DRYPOINT® M PLUS(incl. nano-filter)
DRYPOINT® M PLUS (incl nano-filter)
DRYPOINT® RA
V + RF (oil-free)
V + RF (oil-free)
Compressed air condensate dispersed
Compressed air condensate emulsified
DRYPOINT® RA
R (F) S
DRYPOINT® AC (including S + RF filter) or EVERDRY®
BEKOKAT®
V (up to 200 m3/h)** RS
V (up to 200 m3/h)** RS
A***
V (up to 200 m3/h)** RS
A***
V (up to 200 m3/h)** RS
A***
V (up to 200 m3/h)** RS
A***
A***
Compressed air pipe-work Discharge of condensate
* An optional filter extends the service life of the downstream filters here** Also oil-free as an option *** A CLEARPOINT A activated carbon filter can also be inserted here . The quality classes in accordanc with ISO
8573 standards with remain the same:, the service life of an active carbon filter is less than that of the CLEAR-POINT® V. In addition, a CLEARPOINT® nano-filterr can also be inserted at the point of each application.
DRYPOINT® M
Compressed air processing according to ISO 8573-1: the compressed air schedule shows all possibilities at a glance
Service | BEKO TECHNOLOGIES
53542_new air quality brochure.indd 6 18/03/2016 14:58
ÖWAMAT®
BEKOSPLIT®
Solid particles Pressure dew point Oil vapour
Compressed air processing according to ISO 8573-1: the compressed air schedule shows all possibilities at a glance
1 – 4 – 1 – 5
1 – 4 2 – 3 1-5
1 2 – 3 1
1 – 2 4 1-5
1 4 1
1 4 1
1 2 – 3 1 – 5
1 2 – 3 1
1 2 – 3 1-5
1 2 – 3 1
1 1 – 3 1
1 1 – 3 1
1 4 < 1
1 1 – 3 1
CLEARPOINT®
Dust filter for RF/RS with manual drainOption: Differential pressure indicator
DRYPOINT® RARefrigeration dryer with BEKOMAT®
PDP + 3 °C
CLEARPOINT® Coalescence filterC/G/F/S/N with BEKOMAT®
Option: Differential pressure indicator of filter management
DRYPOINT® M PLUSMembrane dryer withintegrated nano-filter PDP reduction:< 20 up to > 75 K
CLEARPOINT® AActive carbon filterOption: Differential pressure indicator
DRYPOINT® MMembrane dryerPDP reduction:< 20 up to 75 K
CLEARPOINT® VActivated carbon cartridgeOption: oil check indicator
DRYPOINT® ACAdsorption dryer withinlet and dust filter
CLEARPOINT® VActivated carbon adsorber with with RF dust filter
BEKOSPLIT®
Emulsion splitting plant for emulsified condensates
CLEARPOINT® WWater separator with BEKOMAT®
BEKOKAT®
Catalytic converter
ÖWAMAT®
Oil–water separation systemfor disperse condensates
Compressed air tankwith BEKOMAT®
Class Solid particles,max. quantity of particles per m3
PDP Oil content (liquid, aerosol, oil)
0.1 µm < d ≤ 0.5 µm 0.5 µm < d ≤ 1.0 µm 1.0 µm < d ≤ 5.0 µm °C mg/m3
0 As specified by the manager of the equipment or the supplier, most stringent class 1 requirements
1 ≤ 20,000 ≤ 400 ≤ 10 ≤ –70 ≤ 0.01
2 ≤ 400,000 ≤ 6,000 ≤ 100 ≤ –40 ≤ 0.1
3 - ≤ 90,000 ≤ 1,000 ≤ –20 ≤ 1
4 - - ≤ 10,000 ≤ +3 ≤ 5
5 - - ≤ 100,000 ≤ +7 > 5
6 - - - ≤ +10 -
Air quality according to ISO standard 8573-1:2010
measured according to ISO 8573-4 standards, ref conditions 1 bar absolute, 20 °C, 0% Ur measured according to the ISO 8573-3 standard measured according to ISO 8573-2 and ISO 8573-5 standards, ref conditions 1 bar absolute,., 20 °C, 0% Ur
Service | BEKO TECHNOLOGIES
53542_new air quality brochure.indd 7 18/03/2016 14:58
BEKOMAT®
BEKOMAT® BEKOMAT®
CLEARPOINT®
CLEARPOINT® CLEARPOINT®
CLEARPOINT® CLEARPOINT®
BEKOMAT®
BEKOMAT® ÖWAMAT®DRYPOINT® RA BEKOSPLIT®
DRYPOINT® M PLUS DRYPOINT® M PLUS
CLEARPOINT®
DRYPOINT® AC
Quality with a system. Worldwide.BEKO TECHNOLOGIES develops, manufactures and distributesproducts and systems throughout the world for compressed air andcompressed gases quality. From the processing of compressed airand compressed gas through filtration and drying, via proven condensate technology to instrumen-ts used to monitor and measure the performanceof the plant and the quality of its compressed air. From the smallestcompressed air application up to demanding process technologies..
BEKO TECHNOLOGIES LTD
Unit 11-12 Moons Park, Burnt Meadow RoadNorth Moons MoatRedditch, Worcs, B98 9PATel +44 (0) 1527 575778 Fax +44 (0) 1527 575779info@beko-technologies.co.uk www.beko-technologies.co.uk
XP AUDIT 002 | Edition 2016-03
Since its founding, BEKO TECHNOLOGIES has worked continouslyto the development of compressed air. Our ground breaking ide-as continue to influence on the direction of future development.With this potential and the commitment of our colleagues, BEKO TECHNOLOGIES offers innovative technologies, products andservices
Apart from alterations, all of the data shown does not constitute structural characteristicsaccording to the German Civil Code (BGB). The ® trade-marks registered by BEKO TECHNOLOGIES GmbH, Neuss
Condensate drainage BEKOMAT® | ÖWAMAT® | BEKOSPLIT®
Drying | DRYPOINT®| EVERDRY®
Filtration | CLEARPOINT®
Measurment technology METPOINT®
Process technologyBEKOBLIZZ® | BEKOKAT®
Service
The product and system categories
Service | BEKO TECHNOLOGIES
53542_new air quality brochure.indd 4 18/03/2016 14:58