Clothes Refreshment Machine - CRM

Based on the Nexus 4 dryer structure

2

Introduction New Dryer Platforms

ENV 06 will substitute all the electronic and timer plattforms fortumble dryers.

The substitution involves:

-EDR 1000-EDR 2000- All dryers with mechanical Timers

All user interfaces will be substituted too.

Introduction: August / September 2006

3

Dryer Platforms

Low rangeEDR 1000

Middle rangeEDR 2000

High rangeEDR 3000

4

Tumble Dryer

High Level

Medium Level

Low Level

Timer substitution

5

High Level Appliances

Should be able to do morethan a normal tumble dryer!

6

Competitors

7

MaytagDrying centre

Tumble dryer

Cupboard dryer with

steam treatment

Competitors

8

Siemens Dressman

Ironing & refreshment

Competitors

9

Product Definition

Requirements on performance:

Drying (condensation)- Drying performance are identical to condensation dryer running production 2006- Programme technique, load capacity, no. of drying programmes identical to condensation dryer running production 2006

Real Wool Drying- Suitable for all kind of articles which are sensitive against mechanical agitation (wool, viscose, ... )- For reduced amount of load (1 ... 2 kg)

10

Product Definition

• Clothes refreshing- odour removal procedure with steam or/and fragrance

treatment- textile surface refreshment with steam treatment for cotton, fleece, linen fabrics etc.

- variable process air circuit (switch from open to closed position automatically depending on process step)

• De-wrinkling procedure- very improved easy ironing performance for cotton compared to the existing easy ironing program

- steam treatment for cotton fabrics- improved temperature – mechanic – profile for synthetics

11

100% Cotton After Normal Drying

12

100% Cotton After Steam Drying

13

100% Linen Shirt After Normal Drying

14

100% Linen Shirt After Steam Drying

15

Product Definition - Performance

As a function of material, quantity and programme

– Pre-ironing -> for blouses, shirts, trousers , jackets, skirts, coats etc. from linen, cotton, synthetic for 0,5 to ca. 1 kg laundry, that do not have to be ironed in ideal case

– Refresh -> Usable with not-washable and not washed textiles, Removing of smells, folds and rough creases - possibly is later necessary a ironing, since e.g. also „Bügelfalten“ are removed

– Iron aid -> for all materials because relatively even moisture distribution on and in the materials for 0,5 to ca. 3 kg laundry

16

Definition Drying Process

Air inlet

Hot dry air

Hot humid air

Exit

Condensation

17

Air Ccirculation System

The drying functionality is influenced by two air circulationsystems.• a warm air circuit which is sealed within the appliance• a cold air circuit which circulates ambient air through certain sections of the appliance

The warm air circuit removes the humidity from the clothes fabrics and crosses the cold air circuit inside of the heat exchanger. The result is a thermal exchange which condenses the humidity contained in the warm air.The condensation water is collected in a tank.

18

Humidity Sensing

Conductimetric sensor:

The two halves of the drum are separated by an insulating strip.The impedance of the front and rear shells ( to which the sensorsare connected) varies according tothe wash load, the type of fabricand the degree of humidity.This value is converted into anoscillation of 260Hz and 0Hz bythe electronic.It determines the duration ofthe cycle and the final humidity.

opened circuit : 0Hzclosed circuit : 260Hz +/- 10%

19

DefinitionClothes Refreshment Machine

Water compartment for steam treatment

Fragrance compartment

Pumps

Steam generator

20

Concept Control Panel

Mother Board + U.I. BOX

LEDS board BOX

ShaftTransparent part

Control Panel

KNOB

Board for LEDS

Cover for knob

Over-injected opaque part

21

Technical Data

Type: Condensation tumble dryer with steam treatment

Voltage: 220/240V – 50Hz (60Hz?)

Heating: - 1400 + 900W (16A – fuse)- 1400 + 600W (10A – fuse)

Motors: 2 Motors (separated drum and fan motors similarto the heat pump dryer)

Steam - Heating (2kW)generator: - Pump (10W)

Electronics: ENV 06 main board with LCD user interface

22

Technical Data

Thermostat: 2 NTC – sensors possible

Door lock: with/without elektronic door opening

Drum light: possible (control by triac)

Sensor: humidity sensor

23

New Features

5 special steam-programs

3 level of steam for 3 level of load (Min, Med, Max)

Dry/wet detection

Steam anti-crease

Odour removal

Iron aid with humidity control

Real wool and silk drying

Full programme functionality of the condensation dryer

24

Introduction CRM

Steam generatorSafety valve connection

25

Introduction CRM

Water compartment for steam generationCompartment for perfume treatment

26

Motors

Motor for drivingthe drum

Motor for fan

27

Why 2 Separate Motors?

CRM performs real wool and silk drying programmes

Movement active pause active pausefor wool 2s 30s 2s 30sfor silk 4s 30s 2s 30s

To create a sufficient air flow it is necessary to haveindependend drum and fan motors.

During the steam programmes the steam should stay in the drum. no air circulation but drum movement no fan

28

Status Of CRM For Production Start

Steam Generator

Steam pipe connection

Soft water loading

Soft water pump

Soft water tank

Steam nozzle

Soft water pipe

29

Water Container And Bottle

Fluff filter for usage of condensed water

Attention! Only destilled water or water from the conden-sation compartment of the dryer should be used.

30

CRM – Control Panel

The cycles are divided in two categories.-Iron Aid programmes with steam treatment-Drying normal drying programmes

Programme selector blue illuminated (LED-board, Macs-bus)

Load DelicateBuzzer

Time Start/Pause

Start delay

Dryness

31

Programmes

Cotton shirts max. 1.2kg

Synthetic shirts max. 1.2kgCotton refresh max. 3kgSynthetic refresh max. 1.5kgBusiness refreshWool max. 1kg

Silk max. 1kgTime programmeLight dry max. 3kg synthetics (6kg cotton)

Cupboard dry max. 3kg synthetics (6kg cotton)Extra dry max. 3kg synthetics (6kg cotton)

32

CRM - Icons

Following the explanation for the icons and working of the LCDdisplay.

33

Load Indication

Adjustable for programmes with steam treatment only

AUTO is shown for all other programmes.If the user tries to change load in a non steam programme, the word AUTO will flash to highlight the fact that the function cannot be altered.

Adjustment for min., med. and max.load according to table in instructionbooklet.

34

Dryness

Adjustment for min., med. and max. degree of dryness.

Adjustable for normal drying programmes onlyAUTO is shown for all other programmes.If the user tries to change dryness in another programme, the word AUTO will flash to highlight the fact that the function cannot be altered.

35

Programme Indication

Delicate

Delay start

Drying

Childsafety

TimeBuzzer

Steamprogramme

Cooling

Anti crease

HumiditySteamphase

Water tankindication

36

Programme Time

If the user tries to change Time ina programme which is not timedefined, the word AUTO will flash to highlight the fact that the functioncannot be altered.

37

Water Compartment For SteamGeneration – No Water AlarmIf the user selects a steam programme and there is not enough water in the compartment (indicated by Reed contact) then theseicons appear and flash to indicate that steam is not possible andthat the user needs to refill water. A sound alert is also triggeredto emphasize this notification

Water compartment for steam generation: max. 1300mlReed-contact active at < 500...600ml water levelWater consumption for steam programme: 100 – 250ml

38

DryingProcess Area

During the drying phase more and more drops disappear.Additionally the programme remaining time can be watched.

39

LCD – Display During ProgrammePhase

1. Programme-Setup:Programme set but not started. Allphases which the cycle will go throughare shown.

2. Drying phase in progress:Degree of humidity is shown by shirtwith drops animation.

40

LCD – Display During ProgrammePhase

3. Steam phase in progress:Only for steam cycles.

Animation shown in this way.

41

LCD – Display During ProgrammePhase

4. Cooling phase in progress:Drying finished – no drops are shown anymore.

5. Anticrease phase in progress:untill programme end.

42

CRM-programs with steam

Programme Option Load

Cotton steampre-ironing

Dry/wet 0.5-3 kg

Synthetic steampre-ironing

Dry/wet 0.5-1,5 kg

Cotton shirtspre-ironing

Dry/wet 1-5 shirts

Synthetic shirtspre-ironing

Dry/wet 1-5 shirts

Businessrefreshing

Dry 1 trouser -1 jacket, 1 suit, 2 trouser

Iron aid Dry max. 3kg

43

CRM Programmes With SteamCotton

Dry / wet detection

Dry?

Ventilation

Drying to 1% humidity

2 x steam treatment

Cooling

Anticreasing phase / finish

no

yes

44

CRM Programmes With Steam Synthetics

Dry / wet detection

Dry?

Heating up to 65°C (glas point)

Drying to 1% humidity

2 x steam treatment

Cooling

Anticreasing phase / finish

no

yes

45

CRM Programmes With Steam Refresh

Ventilation

2 x steam treatment

Cooling

Anticreasing phase / finish

46

CRM - Simulation

Simulation

For a better understanding of the steam programmes you can start the attached simulation.

47

CRM – ProgrammesDrying cycles

For more details about the cycles press this link.

Cycles

48

Service Mode

Activation:1. Turn programme selector to the first position clockwise

2. Press START/ PAUSE and the left option button simultaneously

3. Within 5 seconds the 3 LEDs start flashing and the buzzer soundsNow service mode is active.

Deactivation: Switch appliance off

1. 2.

3.

49

Service Mode

Attention ! ! !

- To exit the diagnostic mode, switch OFF the appliance.

- Then switch it ON and switch it OFF again(this is to avoid the machine goes into factorytest mode when a diagnostic mode was selected)

50

Service ModeProgramme Selector in Position 1User Interface – Test

Aktivated: All LEDs and LCDs (if present)

Behaviour: All LEDs flash in sequence. Pushing a button will light on thethe corresponding LED and the key number is shown on thedisplay (when available).

All LCD icons flash together.

51

Service ModeProgramme Selector in Position 2Condensation tank switch and pump, steamer tank switch, heater and NTC

Activated: If the pump is filled with water and the tank switch recognises thecondition then the pump is switched on.

Behaviour: If the steamer tank is empty (recognized by a Reed contact) thena warning icon will flash in the LCD display. But the steam heater is powered in any case. The steam heater temperature will be shown in the display.Warning LEDs are switched on

Condition: Door closed (Time out 10min.)

52

Service ModeProgramme Selector in Position 3Steam generator pump and heating and steam pipes (visual test)

Activated: Steamer heater is switched on to maintain steamer temperaturebetween working limits (130°C…150°C)Steamer pump is activated with short impulses (as configured)to allow correct steam generation.

Behaviour: The digits on LCD-Display show NTC2 steamer temperature.Warning LEDs are switched on

Condition: Door closed (Time out 10min.)

53

Service ModeProgramme Selector in Position 4Counter clockwise motor rotation

Activated: Motor-Triac and relais of direction and motor active.Condensations pump active

Behaviour: Warning LEDs are switched on

condition: Door closed (Time out 10min.)

54

Service ModeProgramme Selector in Position 5Slow clockwise motor rotation and reduced fan

Activated: Motor-Triac, motor performs a low speed movement (assemblyline request).Fan motor is activated in inverse direction to test direction relais.

Behaviour: Warning LEDs are switched on

Condition: Door closed (Time out 10min.)

55

Service ModeProgramme Selector in Position 6Heater reduced power and full fan motor

Activated: High heating element, drum motor and fan to give ventilation (full speed)

Behaviour: The digits on LCD-Display show NTC1 drying temperatureWarning LEDs are switched on

Condition: Door closed (Time out 10min.)

56

Service ModeProgramme Selector in Position 7Heater full power and full fan motor

Activated: Both heating elements, drum motor and fan motor to give ventilation

Behaviour: The digits on LCD display show NTC1 drying temperatureWarning LEDs are switched on

Condition: Door closed (Time out 10min.)

57

Service ModeProgramme Selector in Position 8Conductimetric sensor: drum short circuit

Activated: Conductimetric sensor reading

Behaviour: The step lasts 4 seconds. During this time all warning LEDs flash to give information of acquisition phase. At the end of thestep warning LEDs are switched offto give ok, otherwise a sensor alarm is generated.

Condition: Door closed

58

Service ModeProgramme Selector in Position 9Conductimetric sensor: drum open circuit

Aktivated: Conductimetric sensor reading

Behaviour: The step lasts 4 seconds. During this time all phase LEDs flash to give information of acquisition phase. At the end ofthe step Leds are switched off to give ok, otherwise they flash forever. ( no alarm active)

Condition: Door closed

59

Service ModeProgramme Selector in Position 10Condensation tank switch

Activated: Micro switch

Behaviour: Same test like before for assembly test only

60

Service ModeProgramme Selector in Position 11Steam generator tank switch

Aktivated: Reed switch

Behaviour: Same test like before for assembly test only

61

Electric Test Mode

Depending on Software configuration the machine will start theElectric test programme when switching on the appliance afterService mode. In this test programme all electrical componentsWill be activated.Because the power consumption would be too high for the CRM(3 heaters), the electric test mode is splitted in 2 test cycles.

Programme selector in position 1 – EL1:Dryer components active:Drum motor, fan motor, full heating and condensation pump

Programme selector in position 2 – EL2:CRM – components active:Steam heating and steam pump

62

Alarm Management In User Mode

1. Buzzer sounds for alarms which are shown to the customer only (E20, E40, excepted EB0)

2. Buzzer sounds with a specific sequence of three short beepsabout every 20 seconds (for TC1 – appliances a special jingle will be played for warnings)

3. In case of alarm the red Start/Pause – LED flashes as long as the fault condition is present (0,5s on, 0,5s off)

4. For TC1 appliances with graphic LCD display the warnings will be shown as text messages

63

Alarm Management In User Mode

Fast alarm reading is possible like in the presentwashing machine range by pressing the standard key combination about 2 seconds.

64

Alarm Management In Service Mode

1. Turn the programme selector to the alarm memory position

2. Red and green LEDs integrated in Start/Pause key flash alternated according to alarmn code:- Red LED shows the alarm family code (E42 4 times)- Green LED shows the alarm number (E42 2 times)

3. Alarm will be shown completely in time to end display, if LCDdisplay available (example: E42)

4. For graphic LCD user interfaces (TC1) a specific customer screen with complete alarm code and possible supplemen-tary text descriptions can be shown

5. Delete the alarm memory by pressing standard key combination

65

Alarm Management In Service Mode

Attention:

It´s possible to read the last three alarm codes in the alarm memory by pressing a key combination simultaneously.

( Solution still under development )

66

Clear Alarm Memory

The alarm memory can be cleaned in service mode. Use thestandard key combination for 2 seconds in the alarm memory position of the programme selector

Important! After a succesful repair the alarm memory should becleared always.

Standard key combination:Press simoultaneously Start/Pause and the first key left from it.

67

Alarm Table

The failure codes of the EDR1000 / EDR 2000 range are stillvalid.Additionally new alarm codes will be implemented for the CRMcomponents.

The creation of the new alarm table is still in development.

It can be found in the new service manuals for the ENV06

Tumble dryer models when available.

Attached a link to the preliminary alarm table

Alarm table

68

Alarm TableFailure Code Family 2:

tank drain pump

E21: triac-failure

E22: triac sensing failure

69

Alarm TableFailure Code Family 3:

conductimetric sensor

E31: oscillation frequency to highThe conductimetric electronic circuit hasan oscillation frequency out of range

E32: oscillation frequency to lowThe conductimetric electronic circuit hasan oscillation frequency out of range

70

Alarm TableFailure Code Family 4:

Door lock

E45: Door locked – sensing circuit alarm

71

Alarm TableFailure Code Family 5:

Drum motor

E51:motor triac short circuit

E52: motor thermal cut off

E53: motor triac sensing failure

E54: motor jammed

72

Alarm TableFailure Code Family 6:

Heating elements and fan motor

E61: heating elements time out

E62: heating elements relay failure

E63: failure in automatic thermostat sensingE64: motor-triac short circuitE65: motor thermal cut offE66: motor triac sensing failureE67: motor jammed

73

Alarm TableFailure Code Family 7:

NTC - sensor

E71: NTC1-sensor failure (value out of limits)

E72: NTC2-sensor failure(value out of limits)

74

Alarm TableFailure Code Family 8:

Communication

E82: user interface - main board

communication error

E83: user interface - main board protocol

incongruence

75

Alarm TableFailure Code Family 9:

configuration

E93: machine configuration error

E94: cycle configuration error

E95: main board eeprom communication

error

76

Alarm TableFailure Code Family A:

bus - communication

EA1: CRM – electronic communication alarm

EA2: CRM – electronic incongruence alarm

EA3: Selector – LED board communication alarm

EA4: Selector – LED board incongruence alarm

77

Alarm TableFailure Code Family B:

power supply

EB1: power supply frequency out of limits

EB2: power supply voltage too high

EB3: power supply voltage too low

78

Alarm TableFailure Code Family C:

Clothes Refreshment MachineEC1: Main voltage incongruence alarmEC2: Zero-crossing incongruence alarmEC3: Steam generator heating time outEC4: Steam generator heating alarm EC5: Steam generator heating sensing alarm EC6: Steam pump triac alarmEC7: Steam pump triac sensing alarmEC8: Steam generator no water alarm

79

ENV 06 CRM Connection

80

Circuit

Macs Bus

Steam boardCRM board

Main board

Macs Bus

Macs Bus

81

Circuit Main Board

82

CircuitSteam Generator Board

83

CRM - Presentation