Post on 20-Jun-2020
Distribution Center In CANADA+1 506 721 4560www.redsunelectric.cainfo@redsunelectric.ca96 Anchorage Ave,Saint JohnNew Brunswick, CANADA E2K 5R2
High Quality Frequency Inverters
RSE360Series
TechnicalSpecication
Item Specifications
Basic Performance
Rated Input Single-phase: 220V
Three-phase : 220V/380V/480V; Frequency: 50/60Hz
Input voltage range Voltage fluctuation: -15%~10%; Imbalance factor: less than 3%;
Voltage frequency: 47~63Hz
Control mode VF control; Open-loop vector control; Close-loop vector control
Frequency resolution Digital setting: 0.01Hz;
Analog setting: 0.5% × maximum frequency
Maximum output V/F control: 3500Hz; Vector control: 300Hz
Speed range VF control: 1:60; Vector control: 1:100
Carrier frequency 0.5~16.0kHz(Model dependent). The carrier frequency can be automatically adjusted based on features of the load.
Start torque 0.5Hz/150%*rated motor torque
Overload capacity G type: 150% rated current for 60s,180% rated current for 3s
L type: 120% rated current for 60s
Basic Function
Run mode
Keypad; Control terminals (two-line, three-line); Serial communication (RS485).The user can perform switch-over
between these sources in various ways.
V/F curve Straight line type; Multiple point type; N-power type
Ramp curve Straight line or S curve; Four ramp times (range: 0.1s to 6000.0s)
Torque boost Automatic/manual torque boost
Speed trace All types have the function of the speed trace.
Motor braking DC braking; Energy consumption braking; Magnetic braking
DC braking
Braking frequency: 0.00Hz to Maximum frequency; Braking time: 0.0s to 100.0s;
Braking current: 0.0% to 100.0%*Rated motor current
Magnetic braking For occasions which have the request of fast stop or regenerative loads, the function of magnetic braking can be used. The function can avoid frequent protection due to over voltage.
CBC current limiting The function of CBC current limiting is to minimize the fault of over
current and keep the normal running of the AC drive.
Overcurrent and overvoltage control
The function is to restrict the current and voltage automatically during running and avoid the frequent fault protection of over current and over voltage.
Technical Data:
Item Specifications
Special Functions
The delay time of
terminals
The user can set the delay time for digital input terminals, digital
output terminals and relays.The time range is 0.0s to 3000.0s.
JOG Control
Control mode: keypad, terminals and serial communication. Frequency: 0.00Hz to Maximum frequency;
Ramp time: 0.1 to 6000.0s
Multiple speed and simple PLC
Based on built-in PLC or digital input terminals, realize the running of sixteen segments speed.
Two PID inside the
parameters
As common PID, the closed-loop system of process control can be
realized easily.
Fixed length and count
The AC drive can count the pulse signal of 0 to 100K Hz and realize the control of count reaching by using digital output terminals.The
drive can also convert the count into length for display and control.
Spinning and swing
frequency
The fixed swing magnitude, fixed mutations and fixed periodic
output can be achieved at arbitrary frequency.
Timing control Time range: 0 to 65000 hours.
The timing control can stop the AC drive.
Power loss ride through
When the power loss ride through happens, by decreasing the running frequency, the feedback energy of the load can compensate the voltage drop of the DC bus. As a result, the AC
drive can keep running for a short time.
Peripheral terminals
Reference power 10V/30mA.
Usually, it is used for the power supply of analog input signals.
Control power 24V/200mA.Usually, it is used for the power supply of digital input
and output terminals.
Analog input
Two analog input terminals, which have two types of voltage input and current input.
Every input terminal can support three types input signals: 0 to 10V, 0 to 20mA and -10V to 10V.
These two analog input terminals are programmable.
Analog output
Two analog output terminals, which have two types of voltage output and current output.
Every output terminal can support two types output signals: 0 to 10V and 0 to 20mA.
These two analog output terminals are programmable.
Digital input
Five multi function digital input terminals are compatible with active PNP or NPN input mode. Among these six input terminals, the X6 terminal can be chosen as high-speed pulse input terminal and the range of the high-speed pulse is 0 to 100KHz. At the same time, the
X6 terminal is programmable.
Digital output
There are two open collect output terminals. Among them, Y2
terminal can be chosen as high-speed pulse output. These two output terminals are programmable.There are two relay output
Item Specifications
Protection function
Common types
Input and output phase loss protection,under voltage protection, over voltage protection,over current protection,over heat protection, over load protection,short-circuit protection, module fault, external fault, self-defining fault.
Environment
Installation location
Indoor, free from direct sunlight, dust,drip, salt, oil smoke, water vapor, combustible gas and corrosive gas.
Altitude
If the altitude is equal or lower than 1000 meters, the AC drive can be used normally. If the altitude is higher than 1000 meters, it is necessary to de-rate the AC drive. The ratio of derating the AC drive is 1 percent for every increase of 100 meters. If the altitude is higher than 3000 meters, please contact our agents.
Temperature
-10℃ to +40℃. If the ambient temperature is 40℃ to 50℃, please keep good ventilation and take the action of derating: The ratio of derating the AC drive is 3 percent for every increase of 1℃.
Humidity Less than 95%RH, without condensing.
Vibration Less than 0.6g
Storage temperature
-25℃~+65℃
RSE360 - 4T 7R5G/011L - 00 - 00
AC Drive Series
Voltage Class
Rated Power LevelFor HEAVY LOAD
Rated Power LevelFor LIGHT LOAD
Software Code
Hardware Code
Designation Rules:
RSE360-2S class model and technical parameters
AC drive model
RSE360-
Power
capacity
(KVA)
Input
curren(t A)
Output
current
(A)
Brake unit
DC
reactor
Keypad
2S0R7 1.5 8.2 4 Built-in
(Standard)
Not
installed
LED
(Standard) 2S1R5 3 14 7
2S2R2 4 23 9.6
RSE360-4T class model and technical parameters
AC drive model
RSE360-
Power
capacity
(KVA)
Input current
(A)
Output
current
(A)
Brake unit
DC reactor
Keypad
4T0R7G/1R5L 2.0/3.0 3.4/5.0 2.6/3.8
Built-in (Standard)
Not
installed
LED
(Standard)
4T1R5G/2R2L 3.0/4.0 5.0/5.8 3.8/5.5
4T2R2G/3R7L 4.0/5.9 5.8/10.5 5.5/9
4T3R7G/5R5L 5.9/8.9 10.5/14.6 9/13
4T5R5G/7R5L 8.9/11 14.6/18 13/17
4T7R5G/011L 11/16.4 18/25 17/24
4T011G/015L 16.4/21 25/31.2 24/30
4T015G/018L 21/24 31.2/39.2 30/38
4T018G/022L 24/30 39.2/46.5 38/45
4T022G/030L 30/40 46.5/62 45/60
4T030G/037L 40/57 62/78 60/76
4T037G/045L 57/69 78/93 76/91
External
(Optional)
External
(Optional)
4T045G/055L 69/85 93/114.5 91/112
4T055G/075L 85/114 114.5/153.5 112/150
4T075G/090L 114/134 153.5/180 150/176
4T090G/110L 134/160 180/214 176/210
4T110G/132L 160/192 214/256 210/253
4T132G/160L 192/231 256/307 253/304
4T160G/185L 231/240 307/360 304/350
AC drive model
RSE360-
Power
capacity
(KVA)
Input current
(A)
Output
current
(A)
Brake unit
DC
reactor
Keypad
5T0R7G/1R5L 2.0/3.0 3.4/5.0 2.6/3.8
Built-in
(Standard)
Not
installed
LED
(Standard)
5T1R5G/2R2L 3.0/4.0 5.0/5.8 3.8/5.5
5T2R2G/3R7L 4.0/5.9 5.8/10.5 5.5/9
5T3R7G/5R5L 5.9/8.9 10.5/14.6 9/13
5T5R5G/7R5L 8.9/11 14.6/18 13/17
5T7R5G/011L 11/16.4 18/25 17/24
5T011G/015L 16.4/21 25/31.2 24/30
Built-in
(Standard)
Not
installed
LED
(Standard)
5T015G/018L 21/24 31.2/39.2 30/38
5T018G/022L 24/30 39.2/46.5 38/45
5T022G/030L 30/40 46.5/62 45/60
5T030G/037L 40/57 62/78 60/76
External
(Optional)
External
(Optional)
5T037G/045L 57/69 78/93 76/91
5T045G/055L 69/85 93/114.5 91/112
5T055G/075L 85/114 114.5/153.5 112/150
5T075G/090L 114/134 153.5/180 150/176
5T090G/110L 134/160 180/214 176/210
5T110G/132L 160/192 214/256 210/253
5T132G/160L 192/231 256/307 253/304
5T160G/185L 231/240 307/360 304/350
RSE360-5T class model and technical parameters
POWER THE WORLD