Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
1
Contents
1 Power control 3
1.1 Basics 4
1.2 Measurement preprocessing for power control 6
1.3 Power control decision 9
1.4 Power control execution 16
1.5 Power control for AMR calls 25
1.6 Service Dependent Power Control 26
1.7 Derived Handover Power 30
2 Frequency hopping 45
2.1 Introduction 46
2.2 Frequency hopping systems applied in SBS 52
3 Network Synchronization 71
3.1 Basics 72
3.2 Realization in the SBS 72
4 Improved Uplink Interference Cancellation 81
5 Discontinuous Transmission DTX 89
6 Channel allocation due to interference level 93
7 Exercises 99
8 Solutions 107
Interference reduction
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
2
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
3
1 Power control
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
4
1.1 Basics
The objective of power control (PC) is to adapt the transmit power of the MS as well
as of the BTS to the reception conditions. For example a mobile station MS 1 located near the BTS can use a lower transmit power than a mobile station MS 2 at the edge of a cell to achieve the required uplink quality.
There are two advantages of power control:
reduction of the average power consumption (especially in the MS),
reduction of the interference experienced by co-channel (for adjacent) channel users.
Two types of power control are available:
Classic PC
Steps sizes for power control are fixed (2, 4, 6dB) independent of the actual values
for RXLEV and RXQUAL. After a power control command, the power control process is suspended for a certain time.
Adaptive PC
Steps sizes for power control depend on actual value for RXLEV and RXQUAL. The time between two power control decisions is minimized.
Power control is applied separately for the uplink and the downlink and separately for each logical channel. It can be enabled/disabled using the following flags
(administered within the PWRC object):
Specification Name DB Name Meaning
EN_MS_PC EMSPWRC Flag to disable / enable classic / adaptive (def.) uplink power control.
EN_BS_PC EBSPWRC Flag to disable / enable classic / adaptive (def.) downlink power control.
Downlink power control is not applied for downlink bursts using the BCCH frequency.
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T
X
P
W
R
MS 1
T
X
P
W
R
MS 2
BTS
Fig. 1 Required MS transmit pow er depending on its distance to the BTS
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
6
1.2 Measurement preprocessing for power control
Any control loop is based on measurements of the controlled system parameters. For
PC purposes, for each call in progress and for both links (downlink/uplink), measurements of:
received signal level
received signal quality
are carried out over each SACCH multiframe, which is 104 TDMA frames (480 ms) for a TCH and 102 TDMA frames (471 ms) for a SDCCH.
Every SACCH multiframe the MS sends in the next SACCH message block the downlink measurements on the dedicated channel (averaged over one SACCH multiframe) via the Measurement Report message to the serving TRX of the BTS.
This means that any SACCH message will report the averaged data for the previous reporting period only. The TRX performs the uplink measurements on the dedicated
channel. The measurement reports (uplink and downlink) referring to the same SACCH multiframe are used as input parameters for the Measurement Report averaging procedures, implemented within the BTS.
This means that the adjustment of the transmit power of the MS and the BTS is based on following measurement values (refer to Chapter 3.2.2 Measurement
Preprocessing for Handover):
RXLEV_DL_FULL / SUB RXLEV_UL_FULL / SUB
RXQUAL_DL_FULL / SUB RXQUAL_UL_FULL / SUB
The measurement values are preprocessed within the BTS in the same way as for the handover process, i.e. a gliding average window and a weighting of FULL and
SUB values is used. The parameters for measurement preprocessing for power control are administered in the object PWRC and are listed in the table below.
Each sample value is stored together with its weight value (see Figure2). This approach valid both for classic and adaptive PC is a newer one introduced in release BR7.0.
With this method, any window size corresponds to a fixed measurement period and the time to fill the window is always the same. For example, if the window size is n,
the time to fill the window is n*SACCH multiframe period, while with the previous method, the fi lling period is variable and it can varies between n*SACCH multiframe period, in case of all SUB measurements, and (n*SACCH multiframe period)/weight-
value, in case of all FULL measurements.
As drawback the BTS has to manage two buffers, one for the FULL/SUB samples
and the other one for the related weight value.
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20 20 30 30 40 41 20 20 Received power level: RXLEV Samples
SACCH frames
DTXSUB
1 2 3 4 1 2 3 4 Received quality: RXQUAL Samples
20 20 30 30 40 41 20 20
x x x 1 1 x x
A_LEV_PC
x = W_LEV_PC
Averaging windows
SUBFULLFULLFULLFULL FULL FULL
The time to fill the window
A_LEV_PC* SACCH frame durationA_QUAL_PC* SACCH frame duration
4 1 2 3 4
y 1 1 y y
A_QUAL_PC
PWRC object
PAVRQUAL- pcAverangingQual
A_QUAL_PC
W_QUAL_PC
PAVRLEV - pcAverangingLev
A_LEV_PC
W_LEV_PC
y = W_QUAL_PC
1 2 3
Fig. 2 Measurement preprocessing for power control
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
8
Power control correction
This mechanism is necessary to ensure full handover functionality if BS power co ntrol and frequency hopping is enabled.
Normally, if BS PWRC is enabled the MS is informed about this by a flag in the SYS_INFO. This flag makes the MS suppress measurement reports derived from the
BCCH carrier in order to avoid the measurements to be falsified by the full power part of the BCCH.
If frequency hopping is disabled - which could be the case after frequency redefinition
due to failure of a TRX - the MS may hop on the BCCH carrier only. In this case all measurement reports are suppressed (or declared not valid) by the MS which means that no handover is possible. Enabling the power control correction mechanism has the following results:
The BS PWRC flag is set to 0 in the SYS_INFO even if the parameter EBSPWRC=CLASSIC or ADAPTIVE.
The MS thus provides valid measurement reports even for the BCCH carrier.
The BTS takes care that the full power part from the BCCH carrier is correctly substracted from the measurement reports.
Parameters for measurement preprocessing power control
Specification Name
DB Name Range Meaning
A_QUAL_PC PAVRQUAL AQUALPC
1-31
(4)
Averaging window size for RXQUAL values, used for power control
decisions.
W_QUAL_PC PAVRQUAL WQUALPC
1-3
(2)
Weighting for RXQUAL_FULL values.
A_LEV_PC PAVRLEV ALEVPC
1-31
(4)
Averaging window size for RXLEV values, used for power control decisions.
W_LEV_PC PAVRLEV WLEVPC
1-3
(2)
Weighting factor for RXLEV_FULL values.
EN_BS_ PWRC_CORR
EBSPWCR TRUE (def.)/ FALSE
Power control correction in case of BS-power control and frequency hopping.
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
9
1.3 Power control decision
For power control decision the average values of RXLEV_UL/DL and
RXQUAL_UL/DL are compared with some preset thresholds (O&M parameters). A flow chart of the power control decision process is shown in the figure below.
The power control decision is primarily based upon the received signal quality, rather than on the received signal level. The reason behind this, is that the transmitter
power directly affects the quality of the radio link regardless of the overall received signal level, which may be dominated by co-channel interference. If the controlled variable (its average value) lies in the tolerance defined by the thresholds, then no
control action is taken, i.e. a deadband type of control response is produced. This introduces stability into the control process and guarantees an adequate speech
quality. Note, that the controlled variables involved in the algorithm are used in accordance with their coding, e.g. RXQUAL_XX = 0 corresponds to the least BER (best signal quality: BER
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
10
The test
RXLEV_XX > L_RXLEV_XX_P + 2 x POW_RED_STEP_SIZE
should prevent the control loop from oscillating, i.e. a power decrease decision for
quality reasons should not be followed by power increase decision for signal level reasons. Note, that the O&M parameter POW_RED_STEP_SIZE is defined in terms
of a difference between two transmit power levels. An unit power level step corresponds to a nominal 2 dB step in the variation of the transmit power. Field measurements at SIEMENS have shown that even at very low received power levels
a good quality for a radio link can be obtained with a relative high probability. Because sudden fades may deteriorate the quality very rapidly, if the above condition
is satisfied, the received power level is then compared with the corresponding lower threshold to ensure a required minimum power level on the radio link.
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
11
PC Decision
Process
RXQUAL_XXU_RXLEV_XX_P
Power decrease
yes
no
RXLEV_XX POW_RED_STEP_SIZE.
The maximum range for uplink power control is given by:
[13 dBm, Min (MS_TXPWR_MAX, P)] for a GSM-MS Phase 1
[5 dBm, Min (MS_TXPWR_MAX, P)] for a GSM-MS Phase 2 and
for a GSM 850 MS
[0 dBm, Min (MS_TXPWR_MAX, P)] for a DCS1800-MS and
for a PCS 1900-MS
where P is the maximum RF output power of the MS (power class) and
MS_TXPWR_MAX the maximum transmit power allowed in the respective cell. The minimum step size for transmit power adjustment is 2 dB.
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
17
For downlink power control the range is determined by the maximum output power PBTS of the BTS and the static reduction BS_TXPWR_RED of the BTS output power:
BS_TXPWR_MAX = PBTS - 2 * BS_TXPWR_RED
BS_TXPWR_RED = 0, 1, ... 6, Unit: 2 dB.
The range for downlink power control is then given by:
BS_TXPWR_MAX - 30 dB ... BS_TXPWR_MAX with a step size of 2 dB.
In the case of a power control decision a MS/BS Power Control message is created wherein the MS/BS is requested to adjust its transmit power level to:
REQ_TXPWR = CONF_TXPWR + POW_INCR_STEP_SIZE (Power Increase)
REQ_TXPWR = CONF_TXPWR - POW_RED_STEP_SIZE (Power Decrease)
where CONF_TXPWR is the confirmed power level used by the MS or BTS on the
concerned channel. If these values of REQ_TXPWR are not within the range for power control, the nearest value within the range is used instead.
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
18
Having requested a transmit power REQ_TXPWR, the power control decision process is suspended and it is waited for a confirmation that the transmit power of the MS/BTS is adjusted to requested value, i.e.
CONF_TXPWR = REQ_TXPWR.
If such a confirmation is not received within an interval of P_CONFIRM SACCH
multiframes, the power control decision process is immediately resumed using the most recently reported confirmed value.
If a confirmation is received, the power control decision process is suspended for a
certain number of SACCH multiframes given by the parameter P_CON_INTERVAL. The reason for this is to allow an observation of the effect of one power control
decision before initializing the next one; by this means the power control process is stabilized. Thus it is recommended to set
P_CON_INTERVAL > A_QUAL_PC
in terms of a number of multiframes.
The processes and time relations are illustrated in the figure below:
case 1: requested transmit power confirmed
case 2: requested transmit power not confirmed
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
19
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
request
TXPWR
(2)requested transmit power
not confirmed
(1) requested transmit power confirmed
CONF_TXPWR
= REQ_TXPWR
suspension of PC decision
P_CON_INTERVAL
P_CONFIRM
resume
Power Control
resume
Power Control
(2)(1)
time
Fig. 6 Timer usage in the classic power control process
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
20
1.4.2 Adaptive power control
The adaptive power control for circuit switched services applies increment steps, which are automatically adapted to the system's need according to the signal quality (RXQUAL) or to the signal level (RXLEV). The adaptation steps are dynamically
calculated by the system according to current radio conditions.
Calculation of the stepsize:
Fast power increase is applied, if the signal quality average is below
L_RXQUAL_XX_P and the signal level average is below L_RXLEV_XX_P.
stepsize A [dB]:=abs(RXLEV 0.5*(U_RXLEV_XX_P+ L_RXLEV_XX_P))
Fast power increase is applied, if the signal quality average is above
L_RXQUAL_XX_P and the signal level average is below L_RXLEV_XX_P.
stepsize B [dB]:=abs(L_RXLEV_XX_P RXLEV))
Fast power decrease is applied, if the signal quality average is above
U_RXQUAL_XX_P and the signal level average is above U_RXLEV_XX_P.
stepsize C [dB]:= abs(RXQUAL 0.5*(U_RXQUAL_XX_P+ L_Qual_XX_P))
RXQUAL value is considered by its C/I value in dB as well as the values for U_RXQUAL_XX_P and L_Qual_XX_P.
Standard power increase is applied, if the signal quality average is below
L_RXQUAL_XX_P and the signal level average is above L_RXLEV_XX_P.
stepsize [dB]:= POW_INCR_STEP_SIZE * 2dB;
Standard power reduction is applied, if the signal quality average is above
U_RXQUAL_XX_P and the signal level average is above U_RXLEV_XX_P.
stepsize [dB]:= POW_RED_STEP_SIZE * 2dB;
In case of a power reduction for calls using baseband hopping over the BCCH carrier
the resulting power level reduction is checked against a operator-definable absolute maximum reduction (number of 2dB steps), parameter PCMBSPXTRL.
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
21
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RX QUAL
Power Increase
(bad level)
Adaptive stepsize B
Power Increase
(bad quality)
Static stepsize
Power Decrease
(good quality)
Adaptive stepsize C
7
63
RXLEV
0
U_RXQUAL_XX_P
L_RXQUAL_XX_P
L_RXLEV_XX_P
2 x POW_RED_STEP_SIZE
U_RXLEV_XX_P
Power Increase
(bad quality)
Adaptive stepsize A
Power
Decrease
(good quality)
Static stepsize
Fig. 7 Definition of the areas for the different step sizes used in the adaptive power control process
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
22
Additional changes in the adaptive PC process
Others improvements have been included in the adaptive PC process:
1. Updating of previous RXLEV sample values
After a power change decision, all sample values in the RXLEV averaging window are corrected by the respective power level change as if they were already received with the changed power. For MS power control new UL RXLEV samples in the
averaging window are corrected until the power change was confirmed by the MS. Thus, power control can restart soon without suspension time.
2. Automatically evaluation of the suspension time
In the classic PC, after a new power level is decided, the PC process should wait to fill the window with new samples in order to estimate the quality and received level
after the new power level has been commanded. At this purpose, two timers (PWRCONF and PCONINT) are settable.
For the adaptive PC, PCONINT delay timer is evaluated automatically, while there are no changes with respect to the usage of PWRCONF (powerConfirm).
The delay timer is started only when a power change decision is made due to quality
reasons to allow a new set of RXQUAL values to be received and evaluated since with the "adaptive" mode the level samples will be automatically corrected by the
value of the power change. Since the time needed to fill the averaging window depends on the RXQUAL window length (defined by A_QUAL_PC), the delay timer is calculated from that value and will be
RXQUAL window length * 480 [ms] for TCHs and
RXQUAL window length * 470 [ms] for CCHs.
In summary, the setting of A_QUAL_PC defines the minimum time to send two consecutive power change commands for quality reasons, while the setting of W_QUAL_PC has no influence on any reaction time.
As the delay (suspension) timer is not used when the power control decision is made
due to level and as it has automatically evaluated value in case of power control decision due to quality the value of PCONINT is not relevant for the adaptive power control.
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
23
Database Parameters for Power Control Execution
Specification
Name
DB Name
/Object
Range Meaning
MS_TXPWR_
MAX
MSTXPMAXx
(x=GSM, DCS, PCS)
/ BTS
2...15
015
0...15, 30,
31
Maximum TXPWR an MS may use in
the serving cell 2 = 39 dBm, 15 = 13 dBm (GSM900) 0 = 30 dBm, 15 = 0 dBm (DCS1800,
PCS1900)
Def.: 5 (GSM), 0 (DCS, PCS)
Range for uplink power control: 13 dBm ... MAX (GSM, phase 1) 5 dBm ... MAX (GSM, phase 2)
0 dBm ... MAX (DCS, PCS) MAX = Min (MS_TXPWR_MAX, P)
P: power class of the MS
BS_TXPWR_ RED
PWRRED / TRX
0...9
(6)
Static reduction of the TRX output power:
BS_TXPWR_MAX = PBTS - 2 * PWRRED
Range for downlink power control: BS_TXPWR_MAX - 30 dB ... BS_TXPWR_MAX
POW_INCR_ STEP_SIZE
PWRINCSS / PWRC
DB2 DB4
DB6 (def.)
Step size for power increase in dB.
POW_RED_ STEP_SIZE
PWREDSS / PWRC
DB2 (def.) DB4
Step size for power reduction in dB.
P_CONFIRM PWRCONF /PWRC
1...31
(2)
Maximum interval to waiting for a confirmation of the new transmit power
level. Unit: 2 TSACCH
P_CON_ INTERVAL
PCONINT / PWRC
0...31
(2)
Minimum interval between changes of the RF transmit power level (time for
suspension of a PC decision after a PC execution Unit: 2 TSACCH
PC_MAX_BS_ TX_POWER_ RED_LEV
PCMBSTXPRL / PWRC
015
(15)
Maximum BS power reduction level for calls using baseband hopping over the BCCH carrier. Unit:2dB
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
24
PCMBSTXPRL=0 means that no BS downlink power reduction level will be applied for the channels hopping on BCCH.
PCMBSTXPRL=15 means that there are no restrictions in the lower reduction level.
Relations to be observed:
To avoid an oscillating power control due to level the following unequations shall be
fulfilled:
POW_RED_STEP_SIZE < POW_INCR_STEP_SIZE
and
POW_INCR_STEP_SIZE < U_RXLEV_XX_P - L_RXLEV_XX_P
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
25
1.5 Power control for AMR calls
For AMR calls the power control is implemented basing on the same principles as for
non-AMR calls. As already stated in chapter 3 regarding the AMR call HO threshold parameters, harmonization and simplification of attributes and values related to HO and PC have been implemented since this release, i.e. the same threshold
parameters for AMR and non-AMR calls in case of PC are used too.
Database parameters for AMR Power Control are harmonized within the
Service Groups (see next section, SG11PCPARSG14PCPAR) and are the same as for non-AMR calls:
Specification Name DB Name /Object Range Meaning
L_RXQUAL_AMR_DL_P
L_RXQUAL_AMR_UL_P
LOWTQUAD
LOWTQUAU / PWRC
020
(12)
Lower quality threshold on
downlink/uplink for power increase. Unit: 1dB
U_RXQUAL_AMR_DL_P
U_RXQUAL_AMR_UL_P
UPTQUAD
UPTQUAU / PWRC
020
(17)
Upper quality threshold on
downlink/uplink for power decrease. Unit: 1dB
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
26
1.6 Service Dependent Power Control
The feature Service Dependent Power Control is also based on distinguishing the
fourteen CS service groups as defined in Chapter 3. This concerns Signaling services, Circuit-Switched services (CS) on Half Rate (HR), Full Rate (FR), Enhanced Full Rate (EFR), Adaptive Multi-Rate (AMR), Advanced Speech Call Items
(ASCI), Voice Broadcast Services (VBS), Voice Group Call Services (VGCS), and High Speed Circuit-Switched Data services (HSCSD).
For each service group relevant threshold parameters for Power Control can be defined individually. If parameters are not set for a service group (default value "NULL"), global parameter settings is implemented. It is possible to define specific
PC parameters for some selected service groups and leave the others unchanged.
The SG quality attributes for PC are also adapted to the new units/ranges in BR 9.0.
These parameters are part of the attribute SGxPCPAR x=1,2,16 in the object SET PWRC. The attribute is composed of 16 fields.
Example:
SG3PCPAR=CLASSIC-CLASSIC-TRUE-25-25-25-35-10-12-12-17-17-NULL-NULL
or
SG14PCPAR=CLASSIC-CLASSIC-TRUE-20-20-30-23-10-8-8-14-14-NULL-NULL
with the following meaning:
SGxPCPAR=EBSPWRS-EMSPWRC-EPRWCRLFW-LOWTLEVD-LOWTLEVU-
UPTLEVD-UPTLEVU-PCRLFTH-LOWTQUAD-LOWTQUAL-UPTQUAD-
-UPTQUAU-RDLNKTBTS-RDLNKTO.
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
27
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PWRC
PWRC parameters: NAME EBPWRC EMSPWRC
SG1PCPAR SG1PCPAR
SG14PCPAR
PCMBXTSPRL
Standard settings
for all SGs that
are not activated
PWRC parameters for SG1:
enableBSPowerControl enableMSPowerControl
PCUpperThresholdQualUL
PWRC parameters for SG14:
enableBSPowerControl enableMSPowerControl
pcradioLinkTimeoutBs
Special settingsfor Service Groups that are activated
PCUpperThresholdQAMRUL
pcradioLinkTimeoutMs
Fig. 8 Principle of service dependent power control
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
28
Parameter Description
EBSPWRC Enable Base Station Power Control
EMSPWRC Enable Mobile Station Power Control
EPWCRLFW Enable Radio Link Failure Warning
LOWTLEVD Lower DL RXLEV Threshold
LOWTLEVU Lower UL RXLEV Threshold
UPTLEVD Upper DL RXLEV Threshold
UPTLEVU Upper UL RXLEV Threshold
PCRLFTH Threshold for Radio Link Failure Counter
LOWTQUAD Lower DL receive signal quality Threshold
LOWTQUAU Lower UL receive signal quality Threshold
UPTQUAD Upper DL receive signal quality Threshold
UPTQUAU Upper UL receive signal quality Threshold
RDLNKTBS Radio Link Timeout BS counter value:
Range 0-15, 0=4*SACCH,...15=64*SACCH (10)
RDLNKTO Radio Link Timeout MS counter value:
Range 0-15, 0=4*SACCH,...15=64*SACCH (10)
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
29
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fig. 9
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
30
1.7 Derived Handover Power
Currently the maximum TX power is used after all intercell handovers until the power
control procedure has reduced the power to a required minimum level. As a consequence higher interference level after handovers (HO) is very often the case.
The BR9.0 feature Derived Handover Power (DHP) enables BSS and mobile station
to avoid the unnecessary usage of maximum transmit (TX) power on the air interface after having performed a handover, and thereby reduce interferences.
By using a derived power (TX power before HO +security margin) during uplink and downlink handovers, the TX power can be limited to the real need.
Network operators can enable/disable the Derived Handover Power feature per
neighbor cell relationship individually for UL and DL direction and set different margins to customize the feature according to the actual needs in the cell.
The Derived HO Power feature is applicable in case of:
Scenario: Intercell/Intra BSC HO,
HO type: Better Cell HO and Mobile Speed Sensitive HO,
On the first Better Cell HO for this channel (if a HANDOVER FAILURE towards the same target cell has taken place before, DHP is not applied),
Service type: CS voice (AMR and all non-AMR calls), CS data, signaling in case of SDCCH-SDCCH handover, ASCI UL (VGCS) and HSCSD.
The benefit for an operator is a decrease of the overall interference which means the
system capacity increases in the interference limited scenarios.
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BTSserv BTStarget
Signaling
Traffic
Neighbor
Cell Measmnt.
Path-loss
Pathloss = f {MSdedicated mode-Measurements, System parameters}
TXpwrDL = f {Pathloss between MS and BTStarget}
TXpwrUL = f {TXpwrDL} [HO Command]
The Tx Power to be used after the HO is
mainly a function of
the momentary path-
loss on the air
interface
Fig. 10 Derived Handover Pow er feature
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
32
1.7.1 Optimal MS/BS transmission power calculation
When an MS performs a handover from one BTS (serving BTS) to another BTS (target BTS), it is possible for the BSS to calculate the optimal UL and DL TX power for the connection between MS and the target BTS. This is achieved by enabling the
DHP feature which calculates and applies the optimal MS and BS transmission power values in the target cell immediately after power budget handover.
Thus DHP avoids interference by avoiding unnecessary high MS and BS Power levels directly after an inter-cell handover due to better cell. T
The MS and BS power values are calculated based on:
1. Neighbor cell RXLEV and (idle TCH) UL interference measurements (MEASUREMENT REPORTs from MS and Idle TCH measurements performed by the target BTS)
2. Database parameters, which have to be carefully set after qualified estimations or field measurements.
The DHP calculation is done in the handover target BTS, after reception of the
CHANNEL ACTIVATION message for the target TCH.
For this, the INTERCELL HANDOVER CONDITION INDICATION message from the serving cell contains the averaged RXLEV values of the (2G) target cells
(RXLEVtarget).
When a target cell was selected for handover, the BSC adds the corresponding
RXLEVtarget value and a flag indicating which DHP direction (UL/DL) is enabled, to the CHANNEL ACTIVATION message that is sent towards the target BTS.
The target BTS calculates the suitable MS and/or BS transmit power and sends the
resulting MS Power value back to the BSC (DHP UL).
The BSC inserts the received MS Power value into the IE Power command in the HANDOVER COMMAND message (DHP UL).
The target BTS commands the calculated MS Power value in the SACCH layer 1 header (DHP UL) and adjusts the initial BS Power to the calculated value (DHP DL).
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
33
Fig. 11 Intercell HO execution steps
CHANNEL ACTIVATION ACK
INTERCELL HCI (better cell)
RXLEVtarget included for 2G target cells
DHP UL/DL
enabled?
HANDOVER COMMAND
CHANNEL ACTIVATION
BTS
calculates
MS Powerand/or
BS Power
HANDOVER COMMAND
HANDOVER COMPLETE
FACCH
SABM
FACCHUA
FACCH
HANDOVER ACCESS
FACCH
PHYSICAL INFO
FACCH
BTS
applies
calculated
BS Power and commands
MS Power in SACCH layer-1
header
HANDOVER DETECT
MS BTSserving BSC BTStarget
RXLEVtarget included
DHP UL
DHP DL
MS Power included
MS Power in IE
Power Command
MS applies
commanded
MS Power
Fig. 12 DHP Operational Sequence
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
34
1.7.1.1 DHP Calculation Algorithm in target BTS
To determine the optimum transmit power to be used after HO, at first the pathloss
between the MS and the target BTS must be calculated by means of the MS neighbor cells measurements.
The basic calculation of the optimum MS and BS Power in the handover target cell is
based on the assumption that uplink pathloss and downlink pathloss have the same value.
The pathloss (PATHLOSS_DL or PATHLOSS_UL) is calculated by utilizing measurements carried out by the MS in dedicated mode (neighbor cell measurements) and some system parameters as mentioned above.
The following aspects are being considered by the calculation of the optimum TX power to be used after HO within the target BTS:
RF Feeder Cables
Combiner
TMA
Transmit Diversity
Receive Diversity
Dual Band / Single BCCH
UL Interference
Neighbor Cell measurement C/I
Mobile Station TX Power Capability
Base Station maximum TX power.
The following correction factors must be estimated and configured by the operators:
Security margin (including tolerances)
Unknown DL Interference,
if a significant DL interference is expected but cannot be estimated, Derived HO
Power should be used for UL only.
Once calculated, the TX power values are used in the BTS (DL direction) and can be commanded to the MS (UL direction) as a part of the Handover Command message
that is sent from the BSC to the MS.
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
35
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
compo
PATHLOSS_DL
PATHLOSS_UL
PATHLOSS_DL = BSPOWERANT RXLEV_DL
PATHLOSS_UL = MSPOWER RXLEV_ULANT
Fig. 13 Components of the PATHLOSS_DL/UL calculation
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
36
DHP Basic MS Power Calculation Algorithm in target BTS
Basic algorithm for the calculation of the optimum MS Power in the target cell is based on assumption that the PATHLOSS_DL is equal to the PATH LOSS_UL:
PATHLOSS_DL = BSPOWER RXLEV_DL
PATHLOSS_UL = MSPOWER RXLEV_UL
and assuming that
PATHLOSS_DL = PATHLOSS_UL
the equation
BSPOWER RXLEV_DL = MSPOWER RXLEV_UL
can be re-arranged for calculation of the MS Power as follows:
MSPOWER = BSPOWER - RXLEV_DL + RXLEV_UL.
To achieve an MS Power value which reflects a real optimum under the current
conditions from RXLEV perspective, the equation terms are replaced as follows:
BSPOWER BSPOWERtarget-max = Maximum possible BS transmit power in target
cell,
RXLEV_DL RXLEV_DLtarget-mea = DL RXLEV of target cell as measured and
reported by MS,
RXLEV_UL RXLEV_ULtarget-op = Desired (optimum) RXLEV UL in target cell, =
arithmetic mean of upper and lower uplink power control RXLEV threshold , i.e.
RXLEV_ULtarget-op = (UPTLEVU+LOWTLEVU)/2.
This results in the following calculation formula:
MSPOWERRXLV = BSPOWERtarget-max - RXLEV_DLtarget-mea + RXLEV_ULtarget-op
MSPOWERRXLV = Current_Pathloss_DL + Optimum_UL_RXLEV,i.e.
the optimum MS Power (RXLEV p.o.v.) is the sum of
1. the optimum UL RXLEV as intended by the operator, represented by the middle of the Power Control Level Window which is defined by the upper and lower UL RXLEV thresholds for Power Control and
2. the current DL pathloss which the MS must overcome.
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
37
In addition to the RXLEV based calculations and parameters, the target channels UL C/I conditions must be considered.
For this reason, the BTS calculates an additional optimum MS Power value, that
guarantees acceptable UL C/I conditions after handover.
Of both calculates values, the BTS will select the higher one, i.e.,
MSPOWERopt = max(MSPOWERRXLV, MSPOWERC/I)
In detail, the BTS checks the following additional C/I condition
MSPOWERC/I Opt_C/I_UL + UL_Interf + (BSPOWERtarget-max - RXLEV_DLtarget-mea)
where
Opt_C/I_UL = Optimum (desired) C/I UL in target cell= arithmetic mean of upper and lower uplink power control C/I threshold, i.e. (UPTQUAU+LOWTQUAU)/2
UL_Interf = UL interference as measured by the BTS on the idle target channel
BSPOWERtarget-max = Maximum possible BS transmit power in the target cell
RXLEV_DLtarget-mea = DL RXLEV of target cell as measured and reported by MS.
The above formula
MSPOWERC/I Opt_C/I_UL + UL_Interf + (BSPOWERtarget-max - RXLEV_DLtarget-mea)
can be wtitten as
MSPOWERC/I = Opt_C/I_UL + UL_Interf + Current_Pathloss_DL
Therefore, the resulting optimum MS Power must be the sum of
1. the optimum UL C/I, represented by the middle of the Power Control C/I Window which is defined by the upper and lower UL C/I thresholds for Power Control
2. the UL signal currently interfering the target channel which the MS must drown out.
3. the current DL pathloss which the MS must overcome.
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
38
Additional factors related to MS Power Calculation
In addition to the above basic RXLEV and C/I related MS Power calculations, further additional factors must be considered.
One factor to be considered is the feature Transmit Diversity.If Transmit Diversity is enabled in the handover target cell (and, consequently, the CUs are combined on air via two antennas), an additional 3dB gain is achieved in the DL of the target cell.
As this gain is included in the DL value measured by the MS, but does not exist in the UL, the 3dB DL gain must be considered in the MS Power calculation by adding 3dB
to the calculation result of the basic algorithm.
In case the handover target cell is a dual band cell (Dualband Concentric or Dualband Standard Cell), the pathloss difference (PLD) between the different frequency bands is considered in addition.
For both types of cells, it may happen that the neighbor cell measurements are performed for one frequency band (e.g. GSM900 used as BCCH frequency) but the
target TCH is assigned on a TRX on the other band (e.g. DSC1800).
If this scenario applies, an estimated PLD is added to the result.
The PLD is represented by an Additional PL Dualband cell term which is defined by parameter ADDPATHLDBC (PWRC object); its default value depends on the SYSID setting and the frequency band allocation of the TRXs.
This PLD parameter is not only applied for the calculation of the optimum MS Power in the target cell, but also for the optimum BS Power.
These tolerances are considered by a DHP Security Margin which can be defined by parameter DERHOPWRSM (PWRC object), default value = 5dB.
For a correct determination of the MS Power, system tolerances in measurement and
adjustment must be considered (BTS/MS receiver accuracy tolerances and BTS/MS transmit power accuracy all dependent on conditions and RXLEV range). The DHP Security Margin is applied for the calculation of the optimum MS Power in the target cell, as well as for the optimum BS Power.
Without DHP applied, the maximum allowed transmission power the MS may apply
on the assigned handover target channel is defined by the parameter MSTXPMAXx (x=GSM, DCS or PCS depending on the used frequency band). Up to BR8.0, this value was considered for the initial MS Power after HO.
In BR9.0, it is possible to define a maximum power reduction related to the setting of
defined by the parameter MULPWRRED (PWRC object), default value = 6dB.
A corresponding parameter is also available for the DL direction (parameter MDLPWRRED.
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
39
DHP Basic BS Power Calculation Algorithm in target BTS
Like for the MS Power calculation case, the optimum RXLEV is assumed to be the middle of the Power Control Level Window (arithmetic mean of upper and lower PWRC level threshold).
Considering that the BS TX signal must overcome the current DL pathloss, the
optimum BS Power (from RXLEV point of view) is calculated as follows:
BSPOWERRXLV = Current_Pathloss_DL + RXLEV_DLtarget-op
BSPOWERRXLV = BSPOWERtarget-max RXLEV_DLtarget-mea + RXLEV_DLtarget-op
where
RXLEV_DLtarget-op = Desired RXLEV DL in target cell, = arithmetic mean of upper and
lower downlink power control RXLEV threshold , i.e. (UPTLEVD+LOWTLEVD)/2
BSPOWERtarget-max = Maximum possible BS transmit power in target cell
RXLEV_DLtarget-mea = DL RXLEV of target cell as measured and reported by MS.
In addition to these RXLEV based calculations and parameters, the target channels DL C/I conditions must be considered.
In contrast to the UL, however, the DL interference can only be estimated.
Based on this estimation, the BTS calculates an additional optimum BS Power value,
that guarantees acceptable DL C/I conditions after handover.
Of both calculates values, the BTS will select the higher one, i.e.
BSPOWERopt = max(BSPOWERRXLV, BSPOWERC/I).
In detail, the BTS checks the following additional C/I condition
BSPOWERC/I Opt_C/I_DL + DL_Interf + (BSPOWERtarget-max - RXLEV_DLtarget-mea)
where
Opt_C/I_DL = Optimum (desired) C/I DL in target cell = arithmetic mean of upper and lower uplink power control C/I threshold, i.e. (UPTQUAD+LOWTQUAD)/2,
DL_Interf = Estimated DL interference, as defined by parameter ESTDLINT,
BSPOWERtarget-max = Maximum possible BS transmit power in the target cell,
RXLEV_DLtarget-mea = DL RXLEV of target cell as measured and reported by MS.
Therefore, the formula
BSPOWERC/I Opt_C/I_DL + DL_Interf + (BSPOWERtarget-max - RXLEV_DLtarget-mea)
can be converted as follows
BSPOWERC/I Opt_C/I_DL + DL_Interf + Current_Pathloss_DL.
Interference reduction
RA21616EN09GLS0 2009 Noki a Siemens Networ ks
40
The resulting optimum BS Power must be the sum of:
1. the optimum DL C/I, represented by the middle of the Power Control C/I Window which is defined by the upper and lower DL C/I thresholds for Power Control,
2. the estimated DL Interference on the target channel which the MS must drown out,
3. the current DL pathloss which the MS must overcome.
As mentioned before, additional factors, that had to be considered for a correct calculation of the optimum MS Power in the target cell, have to be considered for the 'Optimum' BS Power calculation, too.
The following factors have to be included in addition when deriving the final 'Optimum' l BS power:
Measurement and adjustment tolerances, reflected by the DHP Security Margin, parameter DERHOPWRSM, default value = 5dB,
Path Loss Difference of Dualband Cells represented by an Additional PL Dualband cell term which is adjusted by parameter ADDPATHLDBC,
Maximum Downlink Power Reduction related to the maximum DL output power
(BSPOWERMAX) of the target cell. This reduction is represented by the parameter MDLPWRRED in the PWRC object, default value = 6dB.
Interference reduction
RA21616EN10GLS0 2009 Noki a Siemens Networ ks
41
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .