Post on 25-Jan-2021
ATLAS COPCOPIT VIPER 271
Lighting Design Simulation Report
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Model No. Luminaire Optic Type QuantityCP24-M-NOP CP24 Flood Light No Optics (120° Beam Angle) 4
CP9-M-L07 CP9 Flood Light L07 (+/- 7° Beam Angle) 1
MC12-D-NOP Machine Light N/A 4
MODEL CP24
OPTIC NOP
ANGLE 45°DIRECTION 90°
MODEL CP24
OPTIC N/A
ANGLE 45°DIRECTION 0°
MODEL CP12
OPTIC N/A
ANGLE 45°DIRECTION 90°
MODEL CP12
OPTIC N/A
ANGLE 90°DIRECTION 0°
MODEL CP9
OPTIC N/A
ANGLE 170°DIRECTION 135°
SUGGESTED LAYOUT
ATLAS COPCO PIT VIPER 271 LIGHTING DESIGN SIMULATION REPORT
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Page 2
Model No. Luminaire Optic Type QuantityCP24-M-NOP CP24 Flood Light No Optics (120° Beam Angle) 4
CP9-M-L07 CP9 Flood Light L07 (+/- 7° Beam Angle) 1
MC12-D-NOP Machine Light N/A 4
MODEL CP24
OPTIC NOP
ANGLE 45°DIRECTION 90°
MODEL CP24
OPTIC N/A
ANGLE 45°DIRECTION 0°
MODEL CP12
OPTIC N/A
ANGLE 90°
DIRECTION 45° MODEL CP12
OPTIC N/A
ANGLE 45°DIRECTION 180°
SUGGESTED LAYOUT
ATLAS COPCO PIT VIPER 271 LIGHTING DESIGN SIMULATION REPORT
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Page 3
Simulated Result
ATLAS COPCO PIT VIPER 271 LIGHTING DESIGN SIMULATION REPORT
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Page 4
Simulated Result
Simulated Result
ATLAS COPCO PIT VIPER 271 LIGHTING DESIGN SIMULATION REPORT
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Page 5
0
5
10
15
20
30
50
40
lux0m
10m
-10m
20m
-20m
30m
-30m
0m 10m 20m 30m-20m -10m
Light loss/maintenance factor: 0.85Ambient temperature: 35 C
ATLAS COPCO PIT VIPER 271 LIGHTING DESIGN SIMULATION REPORT
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Page 6
317
371
400
417
403
274
6.2
382
355
410
217
150
96.2
49.3
25.4
6.1
6.3
6.3
329
76.4
8.1
132
6.7
57.6
61.5
65.8
70.7
82.9
96.5
104
89.3
122
304
143
156
170
187
207
229
253
279
113
VERTICAL ILLUMINANCE LEVELS (LUX)ALONG RAISED DRILL MAST
ATLAS COPCO PIT VIPER 271 LIGHTING DESIGN SIMULATION REPORT
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Page 7