Post on 20-Sep-2020
BRICK
CMU
CONCRETE
METAL
EARTH
MORTAR, GROUT, SAND
GYPSUM BOARD
ROUGH LUMBER OR BLOCKING(CONTINUOUS)
ROUGH LUMBER OR BLOCKING(DISCONTINUOUS)
WOOD FINISH
PLYWOOD
BATT INSULATION
RIGID INSULATION
1
A1.1
.
CUTS CONSTRUCTION
SECTION IDENTIFICATION
SHEET WHERE SECTION APPEARS
DETAIL
DETAIL IDENTIFICATION
SHEET WHERE DETAIL APPEARS
ROOM
100ROOM NAME
ROOM NUMBER
101 DOOR NUMBER/OPENING MARK
ELEVATION MARKER
DETAIL MARKER
ROOM MARKER
DOOR MARKER
WINDOW/STOREFRONT/LOUVER MARKER
A1 PARTITION TYPE
PARTITION MARKER
LEVEL0'-0" HEIGHT, ELEVATION MARKER
? GENERAL NOTE MARKER
1
REVISION MARKER
AREA OF REVISION
REVISION IDENTIFICATION
0 BUILDING LINE
A4.2
1
SHEET WHERE ELEVATION APPEARS
ELEVATION IDENTIFICATION
SECTION MARKER
INTERIOR ELEVATION MARKER
A4.2
1
SHEET WHERE ELEVATION APPEARS
ELEVATION IDENTIFICATION2 4
3
1
A1.1
1.
A
B
C
D
E
F
G
H
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
I
@ ATACT ACOUSTICAL CEILING TILESADJ ADJACENTAFF ABOVE FINISHED FLOORALUM ALUMINUMALT ALTERNATE
BARR. BARRIERBLDG BUILDINGBLK/BLKG BLOCKINGBIT. BITUMINOUSBM. BEAMBOT. BOTTOMB.U. BUILT-UP
C CHANNELCAB CABINETCIP CAST-IN-PLACECL CENTERLINECLG CEILINGCMU CONCRETE MASONRY UNITSCOL. COLUMNCONC. CONCRETECONST. CONSTRUCTIONC.J. CONTROL JOINTCONT. CONTINUOUSCORR. CORRIDORCPT CARPETCT CERAMIC TILE
Ø, D DIAMETERD. DEEPDET. DETAILDIA. DIAMETERDISP. DISPENSERDIM. DIMENSIONDN DOWND.S. DOWNSPOUTDTLS. DETAILSDWGS DRAWINGS
EA EACHE.F. EXHAUST FANELEC. ELECTRICALELEV. ELEVATOREL. ELEVATIONEQ EQUALEQUIP. EQUIPMENTE.T.R. EXISTING TO REMAINEXIST. EXISTINGEXP. EXPOSEDEXP. JT. EXPANSION JOINT.EXT. EXTERIOR
F.D. FLOOR DRAINFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFEC02 FIRE EXTINGUISHER CARBON DIOXIDEFHC FIRE HOSE CABINETFIN. FINISHEDFIXT. FIXTUREFL. FLOORFOS FACE OF STUDFP FIREPROOFINGFTG FOOTINGFURR. FURRING
GA GAUGEGALV. GALVANIZEDGEN. GENERALGL. GLASSGWB GYPSUM WALL BOARDGYP BD GYPSUM BOARD
HM HOLLOW METALHB HOSE BIBHC HANDICAPPEDHORIZ. HORIZONTALH.P. HIGH POINTHR HOURHT HEIGHT
INSUL. INSULATIONINT. INTERIOR
J.C. JANITOR'S CLOSETJ.O. JAMB OPENINGJT JOINT
KIT. KITCHEN
LAM. LAMINATELAV. LAVATORYL.F. LINEAR FEETL.P. LOW POINT
M. MEN'S TOILETMACH. MACHINEMAINT. MAINTENANCEMAS. MASONRYMANF. MANUFACTURERMAX MAXIMUMMECH. MECHANICALM.H. MANHOLEMIN MINIMUMM.R. MOISTURE RESISTANTM.O. MASONRY OPENINGMISC. MISCELLANEOUSMTG MOUNTINGMTL METALMULL. MULLION
N.I.C. NOT IN CONTRACTNO. NUMBERNOM. NOMINALNTS NOT TO SCALE
O.C. ON CENTERO.D. OUTSIDE DIAMETEROPER. OPERATINGOPG. OPENINGOPP. OPPOSITE
PART. PARTITIONPASS. PASSAGEPERIM. PERIMETERPL PLATE, PROPERTY LINEPLAS. PLASTERPLAM PLASTIC LAMINATEPOLY. POLYETHELYNEPREFAB PREFABRICATEDPREP. PREPARATIONP.T. PRESSURE TREATEDPTD PAINTED
Q.T. QUARRY TILE
R RISERR.A. RETURN AIRRAD. RADIUSRCP REFLECTED CEILING PLANR.D. ROOF DRAINREF REFERENCE, REFRIGERATORREINF. REINFORCINGRM ROOMR.O. ROUGH OPENINGRQD. REQUIRED
SCHED. SCHEDULESECT. SECTIONSHT SHEETSIM SIMILARS.P. STANDPIPESPECS SPECIFICATIONSSQ. SQUARESS STAINLESS STEELSTL STEELST./STOR/ STORAGESTRUCT. STRUCTURALSUSP. SUSPENDEDSW STORM WATER
T TREADTEL. TELEPHONETH THRESHOLDTHK. THICKNESST.O. TOP OFT&B TOP AND BOTTOMT&G TONGUE AND GROOVETS TRANSITION STRIPTYP TYPICAL
U.L. UNDERWRITER'S LABORATORYU.N.O. UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILEV.B. VAPOR BARRIERVERT. VERTICALVEST. VESTIBULEV.R. VAPOR RETARDER
W. WOMEN'S TOILETWD WOODW/ WITHW/O WITHOUTW.C. WATER CLOSETW.P. WATERPROFFINGWWF WELDED WIRE FABRICWWM WELDED WIRE MESH
ROOF SECTION 1
ROOF SECTION 8
(BID ALTERNATE)
ROOF SECTION 9
(BID ALTERNATE)
ROOF SECTION 2 ROOF SECTION 5
ROOF SECTION 6
ROOF SECTION 7 (CANOPY)
ROOF SECTION 3
ROOF
SECTION 4
ROOF SECTION 7 (CANOPY)1969
1961
ROOF SECTION 1
1961
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
1971
19681937
1963
1963
1986
1986
1963ROOF SECTION 1
YEAR BUILT
ROOF TYPE, REFERENCE SPECIFICATIONS
M
PROFESSIONAL CERTIFICATION: I CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF MARYLAND
LICENSE NUMBER:
EXPIRATION DATE:
no. date revision
© Hord Coplan Macht, Inc.
9
ARCHITECTURE
LANDSCAPE ARCHITECTURE
PLANNING
INTERIOR DESIGN
Drawing
Scale
Date
ARCHITECT
Hord Coplan Macht, Inc.700 E. Pratt St, Suite 1200Baltimore, MD 21202p. 410. 837. 7311 f. 410. 837. 6530
ENVELOPE CONSULTANT
Construction Systems Group, Inc. 1451 Dolley Madison Blvd., Suite 300 McLean, VA 22101p. 703.917.0055 f. 703.917.0464
Project Number
Project Name
8
7
6
5
4
3
2
1
LKJHGFEDCBA C:\Users\jhagan\Documents\Pinehurst ES - Roof Replacement_jhagan.rvt
2/11/2019 1:34:30 PM
As indicated
PINEHURST
ELEMENTARY
SCHOOL ROOF
REPLACEMENT
520 S Pinehurst, Salisbury, MD 21801
CONSTRUCTION DOCUMENTS
FEBRUARY 11, 2019
WICOMICO COUNTY PUBLICSCHOOLS
218345.00
CS.01
COVER SHEET
PINEHURST ELEMENTARYSCHOOL ROOF REPLACEMENT
DRAWING LIST
PINEHURST ELEMENTARY SCHOOL ROOF REPLACEMENT
520 S Pinehurst, Salisbury, MD 21801
ALTERNATES
1. Alternate Lump Sum Base Bid - Provide a price for the substitution of a torch-grade 2-ply modified bitumen
roof system in lieu of application in hot asphalt.
2. Provide an ADD/DEDUCT price for the substitution of foam insulation adhesive in lieu of hot asphalt (NOTE: At
metal decks, base layer of rigid polyisocyanurate thermal insulation will remain mechanically attached). Amount
will apply to both Base Bid and Alternate Base Bid
3. Provide price for Base Bid roof replacement of Roof Section 8 and Roof Section 9 in compliance with the
summary of work and specifications.
4. Provide price for Alternate Base Bid roof replacement of Roof Section 8 and Roof Section 9 in compliance with
the summary of work and specifications
SheetNumber Sheet Name
CS.01 COVER SHEET
ROOF
A1.01 ROOF PLAN
A1.02 ROOF DETAILS
A1.03 ROOF DETAILS
A1.04 ROOF DETAILS
A1.05 ROOF DETAILS
MATERIAL FILL PATTERNS
SYMBOL LEGEND
ABBREVIATIONS
IFB # 91066-192.
ROOF KEY PLAN
APPLICABLE CODES
• 2015 INTERNATIONAL BUILDING CODE• 2015 INTERNATIONAL MECHANICAL CODE• NATIONAL STANDARD PLUMBING CODE (MBPS) 2015 EDITION • 2015 INTERNATIONAL ENERGY CONSERVATION CODE• 2015 INTERNATIONAL EXISTING BUILDING CODE
3E
A1.03
3J
A1.03
3A
A1.03
6J
A1.03
6E
A1.03
RD
RD
RD RD
RD RD
RD RD
RD RD
RD RD
RD RDRD RD RD RD
RD
EX. FAN EX. FAN
GV GV
VTR
VTR
GV
GV
GV
GV
EX. FAN
EX. FAN
VTR
VTR
VTRVTR
EX. FAN
2F
A1.04
2J
A1.04
TYP.
TYP.
2D
A1.04
TYP.
2J
A1.04
TYP.
EXISTING ACCESS LADDER WITH CAGE
GV
GV
GV
EX. FAN
VTR
VTR
GV
GV
GV
EX. FAN
EX. FAN
GV
VTR
VTR
VTR
EXPANSION JOINT
EXPANSION JOINT
EXPANSION JOINT
9J
A1.03
9A
A1.03
3E
A1.03
9J
A1.03
6A
A1.03
9H
A1.04
VTR VTR
EX. FAN
GUTTER
GUTTER
DSDS DS DS
EX. FAN
RTU
PIPE/ELEC. PENETRATIONS
EX. FAN
EXISTING ACCESS LADDER WITH CAGE
RTU
DSVTR
GUTTER
DS
VTR
EX. FAN
PIPE PENETRATION
ELEVATED PVC PIPE
SPLIT SYSTEM UNITS (3)
DUCT PENETRATION (4)
PIPE/ELEC. PENETRATIONS
DS
VTR
VTR
VTR
VTR
EX. FAN EX. FAN
EX. FAN
CANOPY BELOW
GUTTER
GUTTER
GUTTER
EXISTING ACCESS LADDER WITH CAGE
CANOPY BELOW
RD
RD
RD
RD
VTR
VTR
VTR VTR
VTR
VTRVTR
VTR
EX. FAN
VTRVTR
EX. FAN
EX. FAN
EX. FAN
CANOPY BELOW
GUTTER
5G
A1.04
HIGH ROOF
5A
A1.04
9D
A1.04
9A
A1.04
3G
A1.05
6E
A1.05
6E
A1.056E
A1.05
SIM SIM
9J
A1.05
9J
A1.05
9E
A1.05
9E
A1.05
9E
A1.05
9E
A1.05
6E
A1.02
6E
A1.02@ CANOPY@ CANOPY
6E
A1.02@ CANOPY
3J
A1.02
EXPANSION JOINT
EXPANSION JOINT
3A
A1.02
3A
A1.05
3J
A1.03
SIM
LEGEND
AREA NOT INCLUDED IN SCOPE OF PROJECT
RD
GV
VTR
EX. FAN
ROOF DRAIN LOCATION
VENT STACK LOCATION
EXHAUST FAN LOCATION
GOOSE NECK VENT LOCATION
ROOF SECTION 1
ROOF SECTION 8 (BID ALTERNATE)
ROOF SECTION 9 (BID ALTERNATE)
ROOF SECTION 2
ROOF SECTION 5
ROOF SECTION 6
ROOF SECTION 7 (CANOPY)
ROOF SECTION 3
ROOF SECTION 4
ROOF SECTION 7 (CANOPY)
M
PROFESSIONAL CERTIFICATION: I CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF MARYLAND
LICENSE NUMBER:
EXPIRATION DATE:
no. date revision
© Hord Coplan Macht, Inc.
9
ARCHITECTURE
LANDSCAPE ARCHITECTURE
PLANNING
INTERIOR DESIGN
Drawing
Scale
Date
ARCHITECT
Hord Coplan Macht, Inc.700 E. Pratt St, Suite 1200Baltimore, MD 21202p. 410. 837. 7311 f. 410. 837. 6530
ENVELOPE CONSULTANT
Construction Systems Group, Inc. 1451 Dolley Madison Blvd., Suite 300 McLean, VA 22101p. 703.917.0055 f. 703.917.0464
Project Number
Project Name
8
7
6
5
4
3
2
1
LKJHGFEDCBA C:\Users\jhagan\Documents\Pinehurst ES - Roof Replacement_jhagan.rvt
2/11/2019 1:34:29 PM
1/16" = 1'-0"
PINEHURST
ELEMENTARY
SCHOOL ROOF
REPLACEMENT
520 S Pinehurst, Salisbury, MD 21801
CONSTRUCTION DOCUMENTS
FEBRUARY 11, 2019
WICOMICO COUNTY PUBLICSCHOOLS
218345.00
A1.01
ROOF PLAN
PINEHURST ELEMENTARYSCHOOL ROOF REPLACEMENT
1/16" = 1'-0"A1.01
ROOF PLAN9A
1. STORE AND HANDLE ROOFING SHEETS IN A DRY, WELL-VENTILATED, WEATHER-TITE PLACE. STORE ROLLS OF FELT AND OTHER SHEET MATERIALS ON RAISED SURFACE. STAND ALL ROLL MATERIALS ON END. COVER ROLL GOODS WITH A CANVAS TARPAULIN OR OTHER BREATHABLE MATERIAL (NOT POLYETHYLENE).
2. DO NOT LEAVE UNUSED MATERIALS ON THE ROOF WHEN ROOFING WORK IS NOT IN PROGRESS UNLESS PROTECTED FROM WEATHER AND OTHER MOISTURE SOURCES.
3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO SECURE ALL MATERIAL AND EQUIPMENT ON THE JOB SITE. IF ANY MATERIAL OR EQUIPMENT IS STORED ON THE ROOF, THE CONTRACTOR MUST MAKE SURE THAT THE INTEGRITY OF THE DECK IS NOT COMPROMISED AT ANY TIME.
4. DO NOT APPLY ROOFING INSULATION OR MEMBRANE TO DAMP DECK SURFACE.
5. FULLY COMPLETE ALL MODIFIED BITUMINOUS MEMBRANE ROOFING FIELD ASSEMBLY WORK EACH DAY. PHASED CONSTRUCTION WILL NOT BE ACCEPTED.
6. CONTRACTOR TO SUBMIT PULL OUT TEST DATA WITH FASTENING PATTERNS FOR ALL ROOF AREAS.
NOTES:
1. ALL OF GARLAND'S SHOP FABRICATED MATERIAL WILL BE MANUFACTURED TO THE DIMENSIONS SHOWN, UNLESS OTHERWISE NOTED.
2. IT IS ESSENTIAL THAT ANY NECESSARY CHANGES, NOTATIONS OR REQUESTED INFORMATION BE CLEARLY NOTED ON THE SHOP DRAWINGS.
3. NO MATERIAL WILL BE CONSIDERED RELEASED FOR FABRICATION UNTIL ALL PERTINENT INFORMATION (i.e. COLOR, DIMENSIONS, MATERIAL CONFIG-URATION) HAS BEEN RECEIVED.
CUSTOMER NOTES:
0' - 4"
NOTE: SOLDER EXPANSION JOINT COVER SEAMS/ LAPS
2x6 MIN. WOOD NAILER ATTACHED TO SUBSTRATE. OVERALL THICKNESS TO MATCH INSULATION.
WOOD CANT
26 GA. REGLET-MOUNTED STAINLESS STEEL COUNTERFLASHING
LEAD WEDGE 18" O.C.
SEALANT, SEE SPECIFICATION
MEMBRANE SHEET CLOSURE SECURED AND ADHERED TO WALL
POLYISOCYANURATE INSULATION
MODIFIED BITUMEN CAP SHEET
MODIFIED BITUMEN BASE SHEET
1/2" SECUROCK
26 GA. STAINLESS STEEL JOINT COVER WITH T-TYPE CLEAT, SLOPED TO DRAIN
8" M
IN.
FLA
SH
ING
HE
IGH
T
EPDM EXTENDED BACKER/VAPOR RETARDERFASTENERS APPROX. 8" O.C.
EXTEND FIELD PLIES ABOVE TOP OF CANT STRIP
TERMINATION BAR FASTENED @ 8" O.C. THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT)
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
SEALANT, REFERENCE SPECIFICATION
SEAL TOP EDGE OF EXPANSION JOINT COVER TO MASONRY WITH COMPRESSIVE BEAD OF BUTYL SEALANT
BASE SHEET & VAPOR BARRIER
EXISTING TECTUM DECK
26 GA. STAINLESS STEEL PITCH
PAN SOLDERED WATERTIGHT 4" MIN HEIGHT
OPT: WOOD NAILERS; VARIES DEPENDING
UPON SIZE OF PENETRATION
POURABLE SEALANT,
2 PART, 2" MIN.
NON-SHRINK GROUT, 2" MIN.
PREPARE AND PRIME PROJECTION
NOTE: MINIMUM 1" CLEARANCE FROM PENETRATION TO OUTER EDGE OF PITCH PAN. PMMA LIQUID FLASHING IS ACCEPTABLE.
SEALANT, REFERENCE SPECIFICATION
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
MODIFIED BITUMEN CAP SHEET
MODIFIED BITUMEN BASE SHEET
POLYISOCYANURATE INSULATION
1/2" SECUROCK
BASE SHEET & VAPOR BARRIER
SEAL GAP AROUND PENETRATION WITH FOAM
4" MIN.
EXISTING TECTUM DECK
BASE SHEET & VAPOR BARRIER
POLYISOCYANURATE INSULATION
1/2" SECUROCK
MODIFIED BITUMEN BASE SHEET
MODIFIED BITUMEN CAP SHEET
SEAL GAPS AT ALL PERIMETERS WITH FOAM
CANT STRIP
TORCH BASE FLASHING PLY 6" MIN. ON FIELD. EXTEND PLIES UP & OVER WOOD NAILER
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD. EXTEND PLIES UP & OVER WOOD NAILER.
GASKETED FASTENERS @ 24" O.C.
22 GA. GALVANIZED STEEL CONTINUOUS CLEAT FASTENED @ 6" O.C.
26 GA. STAINLESS STEEL STANDING SEAM COPING COVER. PROVIDE POSITIVE SLOPE.
GRANULAR-SURFACED MODIFIED BITUMEN CAP SHEET IN HOT ASPHALT ADHESIVE
MODIFIED BITUMEN BASE SHEET IN HOT ASPHALT ADHESIVE
1/4:12 TAPERED POLYISOCYANURATE INSULATION BOARD IN HOT ASPHALT ADHESIVE
(1) LAYER OF 1.5" POLYISOCYANURATE INSULATION IN HOT ASPHALT ADHESIVE. STAGGER ALL JOINTS.
EXISTING TECTUM DECK
MODIFIED BITUMEN VAPOR BARRIER IN HOT ASPHALT ADHESIVE
1/2" SECUROCK IN HOT ASPHALT ADHESIVE
MECHANICALLY FASTEN BASE SHEET ACCORDING TO WIND UPLIFT CALCULATIONS
GRANULAR-SURFACED MODIFIED BITUMEN CAP SHEET IN HOT ASPHALT ADHESIVE
MODIFIED BITUMEN BASE SHEET IN HOT ASPHALT ADHESIVE
1/4:12 TAPERED POLYISOCYANURATE INSULATION BOARD IN HOT ASPHALT ADHESIVE
(1) LAYER OF 1.5" POLYISOCYANURATE INSULATION IN HOT ASPAHLT ADHESIVE ACCORDING TO WIND UPLIFT CALCULATIONS. STAGGER ALL JOINTS.
EXISTING METAL DECK
MECHANICALLY-ATTACHED 1/2" SECUROCK ON STEEL DECK WITH MODIFIED BITUMEN VAPOR BARRIER IN HOT ASPHALT OVER 1/2" SECUROCK
1/2" SECUROCK IN HOT ASPHALT ADHESIVE
GRANULAR-SURFACED MODIFIED BITUMEN CAP SHEET IN HOT ASPHALT ADHESIVE
MODIFIED BITUMEN BASE SHEET IN HOT ASPHALT ADHESIVE
EXISTING TECTUM DECK
MECHANICALLY FASTEN BASE SHEET ACCORDING TO WIND UPLIFT CALCULATIONS
EXISTING BULB T WELDED TO STRUCTURE
EXISTING ROOF DECK
TERMINATION BAR FASTENED @ 8" O.C. THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT)
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
MODIFIED BITUMEN CAP SHEET
MODIFIED BITUMEN BASE SHEET
SEAL GAPS AT ALL PERIMETERS WITH FOAM
CANT STRIP
SEALANT, REFERENCE SPECIFICATION
26 GA. REGLETMOUNTED STAINLESS STEEL COUNTERFLASHING
LEAD WEDGE 18" O.C.
SEALANT, SEE SPECIFICATION
EXISTING THRU WALL FLASHING
SEALANT, SEE SPECIFICATION
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
EXISTING WOOD BLOCKING
EXTEND PLY OVER BLOCKING FASTEN 8" O.C.
22 GA. GALVANIZED STEEL CONTINUOUS CLEAT FASTENED 6" O.C.
26 GA. STAINLESS STEEL GRAVEL STOP SET IN ROOF CEMENT, NAILED 3" O.C.. STAGGERED, PRIME METAL FLANGE PRIOR TO STRIPPING
2x TREATED WOOD CURB
BASE FLASHING
CANT STRIP
METAL CAP PER SMACNA-ASMM 4TH EDITION PLATE 80 FIG. B
2X TREATED WD BLOCKING AND TREATED PLYWOOD AS REQUIRED. ANCHOR TO DECK. DEPTH OF BLOCKING VARIES WITH LOCATION ON ROOF (TYP).
M
PROFESSIONAL CERTIFICATION: I CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF MARYLAND
LICENSE NUMBER:
EXPIRATION DATE:
no. date revision
© Hord Coplan Macht, Inc.
9
ARCHITECTURE
LANDSCAPE ARCHITECTURE
PLANNING
INTERIOR DESIGN
Drawing
Scale
Date
ARCHITECT
Hord Coplan Macht, Inc.700 E. Pratt St, Suite 1200Baltimore, MD 21202p. 410. 837. 7311 f. 410. 837. 6530
ENVELOPE CONSULTANT
Construction Systems Group, Inc. 1451 Dolley Madison Blvd., Suite 300 McLean, VA 22101p. 703.917.0055 f. 703.917.0464
Project Number
Project Name
8
7
6
5
4
3
2
1
LKJHGFEDCBA C:\Users\jhagan\Documents\Pinehurst ES - Roof Replacement_jhagan.rvt
2/11/2019 1:34:29 PM
1 1/2" = 1'-0"
PINEHURST
ELEMENTARY
SCHOOL ROOF
REPLACEMENT
520 S Pinehurst, Salisbury, MD 21801
CONSTRUCTION DOCUMENTS
FEBRUARY 11, 2019
WICOMICO COUNTY PUBLICSCHOOLS
218345.00
A1.02
ROOF DETAILS
PINEHURST ELEMENTARYSCHOOL ROOF REPLACEMENT
1 1/2" = 1'-0"A1.01 A1.02
ROOF EDGE DETAIL 1986 BUILDING @ 1937 BUILDING3J 1 1/2" = 1'-0"A1.02
PITCH POCKET DETAIL3E
1 1/2" = 1'-0"A1.02
ROOF EDGE DETAIL TYPICAL COPING CAP DETAIL6J
1 1/2" = 1'-0"A1.02
TYPICAL ROOF CROSS SECTION - INSULATED TECTUM DECK9J 1 1/2" = 1'-0"A1.02
TYPICAL ROOF CROSS SECTION - STEEL DECK9E 1 1/2" = 1'-0"A1.02
TYPICAL ROOF CROSS SECTION - TECTUM DECK (CANOPY ROOFS)9A
1 1/2" = 1'-0"A1.01 A1.02
ROOF EDGE DETAIL 1971 BUILDING CANOPY6E
1 1/2" = 1'-0"A1.01 A1.02
ROOF AREA DIVIDER - BU/MOD BIT3A
NOTE: APPLY THIS ASSEMBLY TO ALL STEEL ROOF DECK AREASNOTE: APPLY THIS ASSEMBLY TO ALL TECTUM ROOF DECK AREAS
NOTE: APPLY THIS ASSEMBLY TO ALL CANOPY DECK AREAS
2-1/2" STRUCTURAL INSULATING DECK
WINDOW
EXISTING 3/4" PLYWOOD
BASE SHEET & VAPOR BARRIER
POLYISOCYANURATE INSULATION
1/2" SECUROCK
MODIFIED BITUMEN BASE SHEET
MODIFIED BITUMEN MINERAL CAP SHEET
SEAL GAPS AT ALL PERIMETERS WITH FOAM
EXISTING WOOD BLOCKING
NEW WOOD BLOCKING
EXTEND PLY OVER BLOCKING FASTEN 8" O.C.
22 GA. GALVANIZED STEEL CONTINUOUS CLEAT FASTENED 6" O.C.
SEALANT, SEE SPECIFICATION
26 GA. STAINLESS STEEL GRAVEL STOP SET IN ROOF CEMENT, NAILED 3" O.C.. STAGGERED, PRIME METAL FLANGE PRIOR TO STRIPPING
MODIFIED MEMBRANE
BASE PLY
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
EXISTING TECTUM DECK
BASE SHEET & VAPOR BARRIER
POLYISOCYANURATE INSULATION
1/2" SECUROCK
MODIFIED BITUMEN BASE SHEET
MODIFIED BITUMEN MINERAL CAP SHEET
SEAL GAPS AT ALL PERIMETERS WITH FOAM
EXISTING WOOD BLOCKING
NEW WOOD BLOCKING
EXTEND PLY OVER BLOCKING FASTEN 8" O.C.
22 GA. GALVANIZED STEEL CONTINUOUS CLEAT FASTENED 6" O.C.
SEALANT, SEE SPECIFICATION
26 GA. STAINLESS STEEL GRAVEL STOP SET IN ROOF CEMENT, NAILED 3" O.C.. STAGGERED, PRIME METAL FLANGE PRIOR TO STRIPPING
MODIFIED MEMBRANE
BASE PLY
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
2-1/2" STRUCTURAL INSULATING DECK
WINDOW
EXISTING 3/4" PLYWOODWITH SPRAY COATING
BASE SHEET & VAPOR BARRIER
POLYISOCYANURATE INSULATION
1/2" SECUROCK
MODIFIED BITUMEN BASE SHEET
MODIFIED BITUMEN MINERAL CAP SHEET
SEAL GAPS AT ALL PERIMETERS WITH FOAM
EXISTING WOOD BLOCKING
NEW WOOD BLOCKING
EXTEND PLY OVER BLOCKING FASTEN 8" O.C.
22 GA. GALVANIZED STEEL CONTINUOUS CLEAT FASTENED 6" O.C.
SEALANT, SEE SPECIFICATION
26 GA. STAINLESS STEEL GRAVEL STOP SET IN ROOF CEMENT, NAILED 3" O.C.. STAGGERED, PRIME METAL FLANGE PRIOR TO STRIPPING
MODIFIED MEMBRANE
BASE PLY
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
2-1/2" STRUCTURAL INSULATING DECK
POLYISOCYANURATE INSULATION
TERMINATION BAR FASTENED @ 8" O.C. THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT)
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
MODIFIED BITUMEN CAP SHEET
MODIFIED BITUMEN BASE SHEET
1/2" SECUROCK
CANT STRIP
SEALANT, REFERENCE SPECIFICATION
26 GA. STAINLESS STEEL COUNTERFLASHING
LEAD WEDGE 18" O.C.
SEALANT, SEE SPECIFICATION
EXISTING TECTUM DECK
BASE SHEET & VAPOR BARRIER
EXISTING 2-1/2" STRUCTURAL INSULATING DECK
0' - 2"
1961 PASSAGE1961 BUILDING
EXPANSION JOINT
POLYISOCYANURATE INSULATION
MODIFIED BITUMEN CAP SHEET
MODIFIED BITUMEN BASE SHEET
1/2" SECUROCK
A1.04
2A
BASE SHEET & VAPOR BARRIER
EXISTING 2-1/2" STRUCTURAL INSULATING DECK
EXISTING METAL DECK
EXPANSION JOINT
POLYISOCYANURATE INSULATION
MODIFIED BITUMEN CAP SHEET
MODIFIED BITUMEN BASE SHEET
1/2" SECUROCK
A1.04
2A
BASE SHEET & VAPOR BARRIER
POLYISOCYANURATE INSULATION
TERMINATION BAR FASTENED @ 8" O.C. THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT)
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
MODIFIED BITUMEN CAP SHEET
MODIFIED BITUMEN BASE SHEET
1/2" SECUROCK
CANT STRIP
SEALANT, REFERENCE SPECIFICATION
26 GA. REGLET MOUNTED STAINLESS STEEL COUNTERFLASHING
LEAD WEDGE 18" O.C.
SEALANT, SEE SPECIFICATION
BASE SHEET & VAPOR BARRIER
1/2" SECUROCK
EXISTING 2-1/2" STRUCTURAL INSULATING DECK
EXISTING WINDOW
EXISTING 3/4" PLYWOOD
BASE SHEET & VAPOR BARRIER
POLYISOCYANURATE INSULATION
1/2" SECUROCK
MODIFIED BITUMEN BASE SHEET
MODIFIED BITUMEN MINERAL CAP SHEET
SEAL GAPS AT ALL PERIMETERS WITH FOAM
EXISTING WOOD BLOCKING
NEW WOOD BLOCKING
EXTEND PLY OVER BLOCKING FASTEN 8" O.C.
22 GA. GALVANIZED STEEL CONTINUOUS CLEAT FASTENED 6" O.C.
SEALANT, SEE SPECIFICATION
26 GA. STAINLESS STEEL GRAVEL STOP SET IN ROOF CEMENT, NAILED 3" O.C.. STAGGERED, PRIME METAL FLANGE PRIOR TO STRIPPING
MODIFIED MEMBRANE
BASE PLY
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
METAL DECK
WINDOW
EXISTING 3/4" PLYWOODWITH SPRAY COATING
BASE SHEET & VAPOR BARRIER
POLYISOCYANURATE INSULATION
1/2" SECUROCK
MODIFIED BITUMEN BASE SHEET
MODIFIED BITUMEN MINERAL CAP SHEET
EXISTING WOOD BLOCKING
NEW WOOD BLOCKING
EXTEND PLY OVER BLOCKING FASTEN 8" O.C.
22 GA. GALVANIZED STEEL CONTINUOUS CLEAT FASTENED 6" O.C.
SEALANT, SEE SPECIFICATION
26 GA. STAINLESS STEEL GRAVEL STOP SET IN ROOF CEMENT, NAILED 3" O.C.. STAGGERED, PRIME METAL FLANGE PRIOR TO STRIPPING
MODIFIED MEMBRANE
BASE PLY
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
BASE SHEET & VAPOR BARRIER
1/2" SECUROCK
M
PROFESSIONAL CERTIFICATION: I CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF MARYLAND
LICENSE NUMBER:
EXPIRATION DATE:
no. date revision
© Hord Coplan Macht, Inc.
9
ARCHITECTURE
LANDSCAPE ARCHITECTURE
PLANNING
INTERIOR DESIGN
Drawing
Scale
Date
ARCHITECT
Hord Coplan Macht, Inc.700 E. Pratt St, Suite 1200Baltimore, MD 21202p. 410. 837. 7311 f. 410. 837. 6530
ENVELOPE CONSULTANT
Construction Systems Group, Inc. 1451 Dolley Madison Blvd., Suite 300 McLean, VA 22101p. 703.917.0055 f. 703.917.0464
Project Number
Project Name
8
7
6
5
4
3
2
1
LKJHGFEDCBA C:\Users\jhagan\Documents\Pinehurst ES - Roof Replacement_jhagan.rvt
2/11/2019 1:34:30 PM
1 1/2" = 1'-0"
PINEHURST
ELEMENTARY
SCHOOL ROOF
REPLACEMENT
520 S Pinehurst, Salisbury, MD 21801
CONSTRUCTION DOCUMENTS
FEBRUARY 11, 2019
WICOMICO COUNTY PUBLICSCHOOLS
218345.00
A1.03
ROOF DETAILS
PINEHURST ELEMENTARYSCHOOL ROOF REPLACEMENT
1 1/2" = 1'-0"A1.01 A1.03
ROOF EDGE DETAIL 1961 BUILDING @ EAST3E 1 1/2" = 1'-0"A1.01 A1.03
ROOF EDGE DETAIL 1961 BUILDING @ NORTH3J 1 1/2" = 1'-0"A1.01 A1.03
ROOF EDGE DETAIL 1961 BUILDING @ EAST PASSAGE3A
1 1/2" = 1'-0"A1.01 A1.03
ROOF EDGE DETAIL 1961 BUILDING @ 1937 BUILDING6J 1 1/2" = 1'-0"A1.01 A1.03
ROOF EDGE DETAIL 1961 BUILDING @ PASSAGE6E
1 1/2" = 1'-0"A1.01 A1.03
ROOF EDGE DETAIL 1968 BUILDING @ SOUTH9A 1 1/2" = 1'-0"A1.01 A1.03
ROOF EDGE DETAIL 1968 BUILDING @ EAST9J
1 1/2" = 1'-0"A1.01 A1.03
ROOF EDGE DETAIL 1986 BUILDING @ PASSAGE6A
CL
ALL PLIES EXTEND UNDER CLAMPING RING
INSULATED LEADER
EXISTING TECTUM DECK
BASE SHEET & VAPOR BARRIER
POLYISOCYANURATE INSULATION
1/2" SECUROCK
TAPERED 8'X8' SUMP,MINIMUM THICKNESS IS 2"
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
4 LB. LEAD FLASHING (30" MIN.) SET IN MASTIC, WRAPPED DOWN 2" MIN., PRIME BOTH SIDES
MODIFIED BITUMEN CAP SHEET
MODIFIED BITUMEN BASE SHEET ROOF DRAIN
8" M
IN.
UNIT MOUNTING CURB
CANT STRIP, FASTENED TO NAILER POLYISOCYANURATE
INSULATION
BASE SHEET & VAPOR BARRIER
EXISTING TECTUM DECK
METAL COUNTERFLASHING FASTENED 8" O.C. SCREW OR RIVET TO FLASHING RECEIVER ONLY
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
MODIFIED BITUMEN CAP SHEET
MODIFIED BITUMEN BASE SHEET
1/2" SECUROCK
SEALING MATERIAL MUST BE CONTINUOUS ON THE PERIMETER
SEALANT, REFERENCE SPECIFICATION
FLASHING RECEIVER
TERMINATION BAR FASTENED @ 8" O.C. THROUGH BUTYL TAPE
4" MIN
MIN
.
1' -
0"
SEAL GAP AROUND PIPES WITH FOAM
EXISTING TECTUM DECK
BASE SHEET & VAPOR BARRIER
POLYISOCYANURATE INSULATION
1/2" SECUROCK
MODIFIED BITUMEN BASE SHEET
MODIFIED BITUMEN CAP SHEET
ROLL DOWN TOP PIECE LEAD FLASHING 1" MIN. DOWN INTO PIPE
PLUMBING VENT STACK
SEALANT, REFERENCE SPECIFICATION
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
SET SOFT METAL FLANGE IN MASTIC, PRIME FLANGE BEFORE STRIPPING
NOTE: MANUFACTURER'S REINFORCED PMMA FLUID APPLIED FLASHING IS ACCEPTABLE
8" M
IN.
EXP JT WIDTH
2" M
IN.
FLEXIBLE VAPOR RETARDER TO SERVE AS INSULATION RETAINER ATTACH TO TOP OF CURB
EXISTING TECTUM DECK
BASE SHEET & VAPOR BARRIER
POLYISOCYANURATE INSULATION
COMPRESSIBLE INSULATION
WOOD CANT1/2" SECUROCK
MODIFIED BITUMEN BASE SHEET
MODIFIED BITUMEN CAP SHEET
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
26 GA. STAINLESS STEEL CLEAT FASTENED 12" O.C.
COVER SECURED 12" O.C. W/ FASTENERS & NEOPRENE WASHERS
FLEXIBLE WATERPROOF MEMBRANE CLOSURE
26 GA. STAINLESS STEEL EXPANSION JOINT COVER
FLASHING FASTENED 8" O.C.
EXP./ CONT.
EXP./ CONT. +1/2"
EXP./ CONT.
1/2"
METAL DECK
POLYISOCYANURATE INSULATION
TERMINATION BAR FASTENED @ 8" O.C. THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT)
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
MODIFIED BITUMEN CAP SHEET
MODIFIED BITUMEN BASE SHEET
1/2" SECUROCK
EXISTING ROOF TO REMAIN
SEAL GAPS AT ALL PERIMETERS WITH FOAM
CANT STRIP
SEALANT, REFERENCE SPECIFICATION
26 GA. STAINLESS STEEL COUNTERFLASHING
LEAD WEDGE 18" O.C.
SEALANT, SEE SPECIFICATION
BASE SHEET & VAPOR BARRIER
1/2" SECUROCK
NOTE: ADJUST WOOD BLOCKING AS NECESSARY TO ACCOMODATE HEIGHT OF INSULATION.
EXISTING DECK
26 GA. STAINLESS STEEL D-STYLE GUTTER
EXISTING WOOD BLOCKING
BASE SHEET & VAPOR BARRIER
POLYISOCYANURATE INSULATION
4" MIN.
SEALANT, REFERENCE SPECIFICATION
26 GA. STAINLESS STEEL CONTINUOUS CLEAT 6" O.C.
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO MATCH GUTTER
FRONT LIP 1" LOWER THAN BACK EDGE
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO
MATCH GUTTER
SEAL GAPS AT ALL PERIMETERS WITH FOAM
GUTTER CLEAT FASTENED 6" O.C.
EXTEND PLY OVER BLOCKING FASTEN 8" O.C.
26 GA. STAINLESS STEEL DRIP EDGE SET IN ROOF CEMENT, NAILED 3" O.C.. STAGGERED, PRIME METAL FLANGE PRIOR TO STRIPPING
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
1/2" SECUROCK
MODIFIED BITUMEN BASE SHEET
MODIFIED BITUMEN MINERAL CAP SHEET
TERMINATION BAR FASTENED @ 8" O.C. THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT)
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
26 GA. REGLETMOUNTED STAINLESS STEEL COUNTERFLASHING
LEAD WEDGE 18" O.C.
SEALANT, SEE SPECIFICATION
26 GA. STAINLESS STEEL D-STYLE GUTTER
EXISTING WOOD BLOCKING
4" MIN.
SEALANT, REFERENCE SPECIFICATION
26 GA. STAINLESS STEEL CONTINUOUS CLEAT 6" O.C.
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO MATCH GUTTER
FRONT LIP 1" LOWER THAN BACK EDGE
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO MATCH GUTTER
SEAL GAPS AT ALL PERIMETERS WITH FOAM
GUTTER CLEAT FASTENED 6" O.C.
EXTEND PLY OVER BLOCKING FASTEN 8" O.C.
26 GA. STAINLESS STEEL DRIP EDGE SET IN ROOF CEMENT, NAILED 3" O.C.. STAGGERED, PRIME METAL FLANGE PRIOR TO STRIPPING
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
SECUROCK
BASE SHEET & VAPOR BARRIER
1/2" SECUROCK
BASE SHEET & VAPOR BARRIER
WING WALL BEYOND
EXISTING 1/2" PLYWOOD
EXISTING 3/8" PLYWOOD
EXISTING DECK
26 GA. STAINLESS STEEL D-STYLE GUTTER
EXISTING WOOD BLOCKING
BASE SHEET & VAPOR BARRIER
POLYISOCYANURATE INSULATION
4" MIN.
SEALANT, REFERENCE SPECIFICATION
26 GA. STAINLESS STEEL CONTINUOUS CLEAT 6" O.C.
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO MATCH GUTTER
FRONT LIP 1" LOWER THAN BACK EDGE
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO MATCH GUTTER
SEAL GAPS AT ALL PERIMETERS WITH FOAM
GUTTER CLEAT FASTENED 6" O.C.
EXTEND PLY OVER BLOCKING FASTEN 8" O.C.
26 GA. STAINLESS STEEL DRIP EDGE SET IN ROOF CEMENT, NAILED 3" O.C.. STAGGERED, PRIME METAL FLANGE PRIOR TO STRIPPING
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
1/2" SECUROCK
MODIFIED BITUMEN BASE SHEET
MODIFIED BITUMEN MINERAL CAP SHEET
NOTE: ADJUST WOOD BLOCKING AS NECESSARY TO ACCOMODATE HEIGHT OF INSULATION.
TERMINATION BAR FASTENED @ 8" O.C. THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT)
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
26 GA. REGLETMOUNTED STAINLESS STEEL COUNTERFLASHING
LEAD WEDGE 18" O.C.
SEALANT, SEE SPECIFICATION
SEALANT
26 GA. STAINLESS STEEL D-STYLE GUTTER
SEALANT, REFERENCE SPECIFICATION
26 GA. STAINLESS STEEL CONTINUOUS CLEAT 6" O.C.
FRONT LIP 1" LOWER THAN BACK EDGE
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO MATCH GUTTER
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO MATCH GUTTER
WRAP EXISTING WOOD WITH NEW ALUMINUM AS REQUIRED
TAPERED INSULATION
1/2" SECUROCK
WINDOW
1937 BUILDING1963 BUILDING
POLYISOCYANURATE INSULATION
TERMINATION BAR FASTENED @ 8" O.C. THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT)
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
MODIFIED BITUMEN CAP SHEET
MODIFIED BITUMEN BASE SHEET
1/2" SECUROCK
CANT STRIP
SEALANT, REFERENCE SPECIFICATION
26 GA. STAINLESS STEEL COUNTERFLASHINGRETURN AT WINDOW SILL
SEALANT, SEE SPECIFICATION
BASE SHEET & VAPOR BARRIER
1/2" SECUROCK
WINDOW
SLOPED ROOF SOFFIT BEYOND TO REMAIN
SCUPPER FROM SLOPED ROOFS ABOVE
SECUROCK
POLUISOCYANURATE INSULATION
EXISTING ROOF DECK
SEALANT
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
CANT STRIP
26 GA. STAINLESS STEEL D-STYLE GUTTER
26 GA. STAINLESS STEEL CONTINUOUS CLEAT 6" O.C.
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO MATCH GUTTER
FRONT LIP 1" LOWER THAN BACK EDGE
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO MATCH GUTTER
GUTTER CLEAT FASTENED 6" O.C.
26 GA. STAINLESS STEEL COUNTERFLASHINGRETURN AT WINDOW SILL
BASE SHEET & VAPOR BARRIER
1/2" SECUROCK
M
PROFESSIONAL CERTIFICATION: I CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF MARYLAND
LICENSE NUMBER:
EXPIRATION DATE:
no. date revision
© Hord Coplan Macht, Inc.
9
ARCHITECTURE
LANDSCAPE ARCHITECTURE
PLANNING
INTERIOR DESIGN
Drawing
Scale
Date
ARCHITECT
Hord Coplan Macht, Inc.700 E. Pratt St, Suite 1200Baltimore, MD 21202p. 410. 837. 7311 f. 410. 837. 6530
ENVELOPE CONSULTANT
Construction Systems Group, Inc. 1451 Dolley Madison Blvd., Suite 300 McLean, VA 22101p. 703.917.0055 f. 703.917.0464
Project Number
Project Name
8
7
6
5
4
3
2
1
LKJHGFEDCBA C:\Users\jhagan\Documents\Pinehurst ES - Roof Replacement_jhagan.rvt
2/11/2019 1:34:30 PM
1 1/2" = 1'-0"
PINEHURST
ELEMENTARY
SCHOOL ROOF
REPLACEMENT
520 S Pinehurst, Salisbury, MD 21801
CONSTRUCTION DOCUMENTS
FEBRUARY 11, 2019
WICOMICO COUNTY PUBLICSCHOOLS
218345.00
A1.04
ROOF DETAILS
PINEHURST ELEMENTARYSCHOOL ROOF REPLACEMENT
1 1/2" = 1'-0"A1.01 A1.04
ROOF DRAIN - BU/MOD BIT2F 1 1/2" = 1'-0"A1.01 A1.04
EQUIP CURB - BU/MOD BIT2J 1 1/2" = 1'-0"A1.01 A1.04
PLUMB VENT PENETRATION - BU/MOD BIT2D 1 1/2" = 1'-0"A1.03 A1.04
ROOF EXP JT DETAIL - BU/MOD BIT2A
1 1/2" = 1'-0"A1.01 A1.04
ROOF EDGE DETAIL 1968 BUILDING @ SOUTH SLOPED ROOF9H
1 1/2" = 1'-0"A1.01 A1.04
ROOF EDGE DETAIL 1963 BUILDING5G 1 1/2" = 1'-0"A1.01 A1.04
ROOF EDGE DETAIL 1963 BUILDING AT CANOPY5A
1 1/2" = 1'-0"A1.01 A1.04
ROOF EDGE DETAIL 1963 BUILDING @ 1937 BUILDING9D 1 1/2" = 1'-0"A1.01 A1.04
ROOF EDGE DETAIL 1963 BUILDING @ CAFETERIA9A
1961 BUILDING1968 BUILDING
EXPANSION JOINT
POLYISOCYANURATE INSULATION
MODIFIED BITUMEN CAP SHEET
MODIFIED BITUMEN BASE SHEET
1/2" SECUROCK
A1.04
2A
BASE SHEET & VAPOR BARRIER
EXISTING TECTUM DECK
EXISTING TECTUM ROOF DECK
EXISTING METAL LATH & STUCCO SOFFIT
EXISTING SOFFIT VENT
EXISTING STRUCTURE
26 GA. STAINLESS STEEL D-STYLE GUTTER
EXISTING WOOD BLOCKING
BASE SHEET & VAPOR BARRIER
POLYISOCYANURATE INSULATION
4" MIN.
SEALANT, REFERENCE SPECIFICATION
26 GA. STAINLESS STEEL CONTINUOUS CLEAT 6" O.C.
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO MATCH GUTTER
FRONT LIP 1" LOWER THAN BACK EDGE
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO MATCH GUTTER
SEAL GAPS AT ALL PERIMETERS WITH FOAM
GUTTER CLEAT FASTENED 6" O.C.
EXTEND PLY OVER BLOCKING FASTEN 8" O.C.
26 GA. STAINLESS STEEL DRIP EDGE SET IN ROOF CEMENT, NAILED 3" O.C.. STAGGERED, PRIME METAL FLANGE PRIOR TO STRIPPING
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
1/2" SECUROCK
MODIFIED BITUMEN BASE SHEET
MODIFIED BITUMEN MINERAL CAP SHEET
NOTE: ADJUST WOOD BLOCKING AS NECESSARY TO ACCOMODATE HEIGHT OF INSULATION.
EXISTING WOOD BLOCKINGWITH NEW ALUMINUM WRAP
SEALANT
EXISTING TECTUM DECK
26 GA. STAINLESS STEEL D-STYLE GUTTER
EXISTING WOOD BLOCKING
BASE SHEET & VAPOR BARRIER
POLYISOCYANURATE INSULATION
4" MIN.SEALANT, REFERENCE SPECIFICATION
26 GA. STAINLESS STEEL CONTINUOUS CLEAT 6" O.C.
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO MATCH GUTTER
FRONT LIP 1" LOWER THAN BACK EDGE
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO MATCH GUTTER
SEAL GAPS AT ALL PERIMETERS WITH FOAM
GUTTER CLEAT FASTENED 6" O.C.
EXTEND PLY OVER BLOCKING FASTEN 8" O.C.
26 GA. STAINLESS STEEL DRIP EDGE SET IN ROOF CEMENT, NAILED 3" O.C.. STAGGERED, PRIME METAL FLANGE PRIOR TO STRIPPING
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
1/2" SECUROCK
MODIFIED BITUMEN BASE SHEET
MODIFIED BITUMEN MINERAL CAP SHEET
NOTE: ADJUST WOOD BLOCKING AS NECESSARY TO ACCOMODATE HEIGHT OF INSULATION.
26 GA. STAINLESS STEEL D-STYLE GUTTER
EXISTING WOOD BLOCKING
BASE SHEET & VAPOR BARRIER
POLYISOCYANURATE INSULATION
4" MIN.
SEALANT, REFERENCE SPECIFICATION
26 GA. STAINLESS STEEL CONTINUOUS CLEAT 6" O.C.
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO MATCH GUTTER
FRONT LIP 1" LOWER THAN BACK EDGE
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS STEEL TO MATCH GUTTER
SEAL GAPS AT ALL PERIMETERS WITH FOAM
GUTTER CLEAT FASTENED 6" O.C.
EXTEND PLY OVER BLOCKING FASTEN 8" O.C.
26 GA. STAINLESS STEEL DRIP EDGE SET IN ROOF CEMENT, NAILED 3" O.C.. STAGGERED, PRIME METAL FLANGE PRIOR TO STRIPPING
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
1/2" SECUROCK
MODIFIED BITUMEN BASE SHEET
MODIFIED BITUMEN MINERAL CAP SHEET
EXISTING WOOD BLOCKINGWITH NEW ALUMINUM WRAP
EXISTING TECTUM ROOF DECK
SEALANT
EXPANSION JOINT
1971 ADDITION1986 ADDITION
POLYISOCYANURATE INSULATION
TERMINATION BAR FASTENED @ 8" O.C. THROUGH BUTYL TAPE (MIN. 1.5" EMBEDMENT)
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
MODIFIED BITUMEN CAP SHEET
MODIFIED BITUMEN BASE SHEET
1/2" SECUROCK
CANT STRIP
SEALANT, REFERENCE SPECIFICATION
26 GA. STAINLESS STEEL COUNTERFLASHING
LEAD WEDGE @ 18" O.C.
SEALANT, SEE SPECIFICATION
A1.04
2A
8" M
IN.
BASE SHEET & VAPOR BARRIER
EXISTING METAL DECK
SEAL GAPS AT ALL PERIMETERS WITH FOAM
BASE SHEET & VAPOR BARRIER
1/2" SECUROCK
CANT STRIP, FASTENED TO NAILER
POLYISOCYANURATE INSULATION
BASE SHEET & VAPOR BARRIER
EXISTING TECTUM DECK
NEW METAL COUNTERFLASHING. 26 GA. STAINLESS STEEL, 1/8" RIVET EVERY 12"O.C.
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
MODIFIED BITUMEN CAP SHEET
MODIFIED BITUMEN BASE SHEET
1/2" SECUROCK
SEALANT, REFERENCE SPECIFICATION
TERMINATION BAR FASTENED @ 8" O.C. THROUGH BUTYL TAPE
8" M
IN.
EXISTING METAL EXHAUST COVER
NOTE: INCREASE HEIGHT OF CURB AS NECESSARY TO MAINTAIN MINIMUM FLASHING HEIGHT
CANT STRIP, FASTENED TO NAILER
POLYISOCYANURATE INSULATION
BASE SHEET & VAPOR BARRIER
EXISTING TECTUM DECK
NEW COUNTERFLASHING, 26 GA. STAINLESS STEEL, 1/8" RIVET EVERY 12" O.C.
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
MODIFIED BITUMEN CAP SHEET
MODIFIED BITUMEN BASE SHEET
1/2" SECUROCK
SEALANT, REFERENCE SPECIFICATION
TERMINATION BAR FASTENED @ 8" O.C. THROUGH BUTYL TAPE
8" M
IN.
4" M
IN.
EXISTING PASSIVE AIR/VENT INTAKE
M
PROFESSIONAL CERTIFICATION: I CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF MARYLAND
LICENSE NUMBER:
EXPIRATION DATE:
no. date revision
© Hord Coplan Macht, Inc.
9
ARCHITECTURE
LANDSCAPE ARCHITECTURE
PLANNING
INTERIOR DESIGN
Drawing
Scale
Date
ARCHITECT
Hord Coplan Macht, Inc.700 E. Pratt St, Suite 1200Baltimore, MD 21202p. 410. 837. 7311 f. 410. 837. 6530
ENVELOPE CONSULTANT
Construction Systems Group, Inc. 1451 Dolley Madison Blvd., Suite 300 McLean, VA 22101p. 703.917.0055 f. 703.917.0464
Project Number
Project Name
8
7
6
5
4
3
2
1
LKJHGFEDCBA C:\Users\jhagan\Documents\Pinehurst ES - Roof Replacement_jhagan.rvt
2/11/2019 1:34:30 PM
1 1/2" = 1'-0"
PINEHURST
ELEMENTARY
SCHOOL ROOF
REPLACEMENT
520 S Pinehurst, Salisbury, MD 21801
CONSTRUCTION DOCUMENTS
FEBRUARY 11, 2019
WICOMICO COUNTY PUBLICSCHOOLS
218345.00
A1.05
ROOF DETAILS
PINEHURST ELEMENTARYSCHOOL ROOF REPLACEMENT
1 1/2" = 1'-0"A1.01 A1.05
ROOF EDGE DETAIL 1961 BUILDING @ 1968 BUILDING3G
1 1/2" = 1'-0"A1.01 A1.05
ROOF EDGE DETAIL 1968 BUILDING @ NORTH6E
1 1/2" = 1'-0"A1.01 A1.05
ROOF EDGE DETAIL 1968 BUILDING @ EAST & WEST9J 1 1/2" = 1'-0"A1.01 A1.05
ROOF EDGE DETAIL 1971 BUILDING @ EAST & WEST9E
1 1/2" = 1'-0"A1.01 A1.05
ROOF EDGE DETAIL 1986 BUILDING TO 1971 BUILDING3A
1 1/2" = 1'-0"A1.05
EQUIP CURB - BU/MOD BIT6A
1 1/2" = 1'-0"A1.05
EQUIP CURB - BU/MOD BIT9A