Appendix hard X-ray
The X-ray imaging system
Some advantages of this setup are:
- location of the virtual slit near the plasma while taking full advantage of the same F# than the uport9 imaging system.
- decrease on the number of crystal/detector arms (to three) at the port plug end
- reducion of the constrains inside the port plug imposed by the 16 discrete lines of sight
- increase of spatial resolution
Upper port
Neutronic analysis has been performed at Garching by Dr. Lida for the Uport9 X-ray system. No gamma ray neither heat deposition analyses have been adressed yet
UPORT9 – The X-ray imaging system
1.E+07
1.E+08
1.E+09
1.E+10
1.E+11
1.E+12
1.E+13
1.E+14
0 100 200 300 400 500 600 700
Distance from the F/W along the View Line
Neu
tron
Flu
xes
(n/c
m2
/s)
0.1<E<1 MeV1<E<2 MeV2<E<5MeV5<E<13.84MeV13.84MeV<Etotal(e>0.1MeV)
•Radiation level at detector is acceptable.•Man access is to avoid at crystal location •Shield is required at crystal location which may increase the scattered flux at detector
crystal
detector
EPORT9 – The X-ray imaging system
EPORT9 & UPORT9 – The X-ray imaging system
Upper imaging system
Graphite LoSEquatorial imaging systems
Improvement 1 to cover gaps (about 15 deg. toroidal component)
Improvement 2 to cover gaps
Large and long spectometer arrangement
Probably to ambicious object size (degrades imaging quality)
X-ray survey at equatorial level
General view