Post on 02-Apr-2018
AMS TS66 CASEMENT WINDOW SYSTEM - SPECIFICATION
AMS Ltd. Wallingstown, Little Island, Co. Cork: Tel: 021 4705100 Fax: 021 4705198, E-mail: pohara@ams.ie, Web: www.ams.ie
2.4.01 J: Profile listing, frames / sashes.
2.4.02 E: Profile listing, transoms/mullions.
2.4.03 K: Profile listing, couplers / adapters.
2.4.04 H: Accessories.
2.4.05 F: Accessories.
2.4.06 H: Sash limitations.
2.4.07 F: Glazing options, TS6202, 011.
2.4.08 D: Glazing options, TS6900.
2.4.09 E: Glazing options, TS6 915.
2.4.10 G: Glazing options, TS6 913, 923, 911
2.4.11 F: Drainage treatment.
2.4.12 E: Drainage treatment.
2.4.13 B: Sash reverser / rebate reverser options.
2.4.14 D: TS6900 - No longer available.
2.4.15 E: Assembly, TS6202, 915.
2.4.16 D: Assembly, TS6202, HL 963.
2.4.17 E: Assembly, TS6202, 913.
2.4.18 F: Assembly, TS6202, 911.
2.4.19 E: Assembly, TS6202, 913 with TBS161.
2.4.20 D: Assembly, TS6202, 913 with TBS151.
2.4.21 F: TS6911 with all around locking.
2.4.22 C: Transom options and adapters.
2.4.23 C: Detail into brick / blockwork.
2.4.24 F: Coupler/Add on/Bay details.
2.4.25 F: Butt hinge options.
2.4.26 D: Curtain wall inserts.
2.4.27 : Assembly, XT6200, TS6913.
2.4.28 : Fixing lug setout brick / blockwork.
2.4.29 C : Glazing, glass packer setout.
2.4.30 : Assembly, TS6202, 923
2.4.31 A : XT cills with riser and end plates
2.4.32 B : XT cills with riser and end plates plus drip
Page : 2.4.01
TS 66 ENERGY CASEMENT WINDOW SYSTEMProfile ListingScale NTS
Revision : J (--/--/--)
Ixx = 36.34 cm4Iyy = 14.96 cm4
Ixx = 28.53 cm4Iyy = 7.39 cm4
Ixx = 30.76 cm4Iyy = 10.24 cm4
Ixx = 43.81 cm4Iyy = 15.37 cm4
Ixx = 30.76 cm4Iyy = 10.24 cm4
HL 211Slim line insert for 28mm glazing
51
31
28
Ixx = 27.07Iyy = 12.04
Ixx = 26.13Iyy = 12.04
28
28
TS6 202FRAME
TS6 011FRAME
TS6 209INSERT FOR 28mm GLAZING
4060
53
73
31
51
28
TS6 210INSERT FOR 28mm GLAZING(Tilt and turn)
HL 963SLIM TEE SASH
28
52 12
TS6 913SASH
TS6 923SASH
TS6 915SASH
72 32
72
48
32
48
20
Ixx = 37.0 cm4Iyy = 21.6 cm4
TS6 912HEAVY DUTY SASH
87
66
Revision : E (--/--/--)Page : 2.4.02
TS 66 ENERGY CASEMENT WINDOW SYSTEMProfile ListingScale NTS
Ixx = 32.42 cm4Iyy = 11.25 cm4
Ixx = 30.63cm4Iyy = 11.25 cm4
Ixx = 93.8 cm4Iyy = 14.98 cm4
Ixx = 129.98 cm4Iyy = 17.86 cm4
Ixx = 238.56 cm4Iyy = 17.37 cm4
TS6 302MULLION / TRANSOM
7636
TS6 315MULLION / TRANSOM
36 28 76
TS6 316MULLION / TRANSOM
TS6 319REVERSER MULLION
TS6 321'Z' TRANSOM
7628
100
36
76 3656
56
50
MULLION / TRANSOMTS6 318
150
Ixx = 632.15 cm4Iyy = 60.41 cm4
36 55
76
Ixx = 164.44 cm4Iyy = 12.55 cm4
FIN MULLIONTS6 375
75
36
66
50mm FIN MULLIONTS6 375-50
Ixx = 339.14 cm4Iyy = 16.28 cm4
24
24
28
75
36
191
141
15
15
36
TS6 314MULLION - TRANSOM
Ixx = 200.18cm4Iyy = 18.00 cm4 TS 319
Ixx = 56.17cm4Iyy = 11.39 cm4 TS302 E
40
876
66
40
8
36
TS6 313MULLION - TRANSOM
TS 314
TS 314
TS 66 ENERGY CASEMENT WINDOW SYSTEMProfile ListingScale NTS
Page : 2.4.03Revision : K (--/--/--)
TS4 230TS CILL
185
80mm EXTENDERTS6 080
HL 56128mm BEAD
TBM DRIPDRIP
HL 50640mm BEAD
HL 50244mm BEAD
HL 50148mm BEAD
80
50mm EXTENDERTS6 085
50
TS6 350IN LINE COUPLER
TS6 352100mm COUPLER
TS6 35150mm COUPLER
100
50
59
90 DEGREE CORNER POSTTB6 802
30
Ixx = 248.9 cm4Iyy = 30.89 cm4
Ixx = 69.63 cm4Iyy = 3.98 cm4
Ixx = 13.85 cm4Iyy = 0.70 cm4
TBS 161REBATE REVERSER
36
HL 562Rebate reverserbead (28mmonly)
HL 563Bead - Slim linetee sash (28mmonly)
TBS 151SASH REVERSER
45
25
HL 56535mm BEAD
TS6 353100mm slim COUPLERIxx = 185.65 cm4Iyy = 7.38 cm4
100
28 28
50 28
140mm EXTENDERTS6 084
For more cill optionsrefer to 2.4.31 & 32
XT6260Cill riser profile
28
XT602828mm add on
140
28
TS6 600TS DRAIN TRAY
CILL200 - 200mm cillCILL170 - 170mm cillCILL145 - 145mm cillCILL120 - 120mm cillCILL100 - 100mm cillCILL60 - 60mm cillCILL30 - 30mm cillCILLE60 - Cill extender
CILLE230D - End cap with drip for 230mm cillCILLE170D - End cap with drip for 170mm cillCILLE145D - End cap with drip for 145mm cillCILLE120D - End cap with drip for 120mm cillCILLE100D - End cap with drip for 100mm cillCILLE060D - End cap with drip for 60mm cillCILLE030D - End cap with drip for 30mm cill
CILLE230S - End cap for 230mm cillCILLE200S - End cap for 200mm cillCILLE170S - End cap for 170mm cillCILLE145S - End cap for 145mm cillCILLE120S - End cap for 120mm cillCILLE100S - End cap for 100mm cillCILLE060S - End cap for 60mm cillCILLE030S - End cap for 30mm cill
XT6 800Bay Pole
XT6 810Bay Pole filletXT6 811
Fillet packer
TS 66 ENERGY CASEMENT WINDOW SYSTEMAccessoriesScale NTS
Page : 2.4.04Revision : H (--/--/--)
HB008 Titon left hand White
Espag locks - TS6 915, TS6 913 & TS6 923
Drain cap:DHCB - BrownDHCB1 - BlackDHCG - OakDHCS - GreyDHCW - White
HD22 - 22" hinge (Self balancing)
HD28 - 28" hingeHD26 - 26" hinge
HD10 - 10" hingestack height hingeHeavy duty 17mm
HD16 - 16" hinge
HD102x - 10" restrictorHD102 - 6" restrictorHeavy duty restrictor
TSWHM - TS Butt hinge - Mill finishTSWHS - TS Butt hinge - silverTSWHB - TS Butt hinge - Black
Butt Hinge - TS6 915
AWH019AWH020
wedge7mm locking
WhiteBlack
DescriptionTiton right hand
Titon left handTiton right hand
Titon right hand
Titon left hand
Titon cockspur handle
HB001
HB006HB005
HB007
HB002
CodeSilver
Black
SilverBlack
White
Colour
gasket
8468Wedge Wedge
3813
gasket gasketWedge CARRA
gasketbead 8467 3821
Seal8470Transomseal gasket
TSCS2Cavity separator(For energy ratedwindows)
3821 VCTVulcanised corner forexternal sash seal
3821 VCVulcanised corner forinternal sash seal
EN1150 - 1150mm espag (22mm backset)EN 950 - 950mm espag (22mm backset)EN 750 - 950mm espag (22mm backset)EN 550 - 950mm espag (22mm backset)EN 350 - 950mm espag (22mm backset)EN 280 - 950mm espag (22mm backset)
Crest butt hinge - 100mmTSHB - BLACKTSHW - WHITETSHN - SILVERTSHM - MILL FINISH
HDHPHinge protector
4500Seal
Espag locks - TS6 915, TS6 913 & TS6 923
EDA1150 - 1150mm espag (22mm backset)EDA 950 - 950mm espag (22mm backset)EDA 750 - 750mm espag (22mm backset)
Offset - disabled access handle
250
Code Description ColourEHWL Prolinea left hand WhiteEHWR Prolinea Right hand WhiteEHBL Prolinea left hand BlackEHBR Prolinea Right hand BlackEHGL Prolinea left hand GoldEHGR Prolinea Right hand GoldEHSL Prolinea left hand SilverEHSR Prolinea Right hand SilverEHCL Prolinea left hand ChromeEHCR Prolinea Right hand ChromeEHWKP Prolinea left hand Key plugEHWKP Prolinea Right hand Key plug
Prolinea espag handle with 15mm spindle
Handle specification for TS6 913,TS6 923, TS6 915 & TS6 911
Heavy duty 'Egress Hinge'HD12E - 12" HD side hung hingeHD16E - 16" HD side hung hinge
MILA releasable restrictor:AWRAR - R/H releasable
restrictor armAWRAL - L/H releasable
restrictor armAWRAS - Fixing stud for
restrictor arm
Cosmofin applicatorCF020 Manual applicatorCF021 Pneumatic applicator
TS66 Frame fixing lug
End cap for TS4 230(TSA 030 - Standard)(TSA 031 - with drip piece)
AccessoriesScale NTS
TS 66 ENERGY CASEMENT WINDOW SYSTEM
TS6 FL
Revision : F (--/--/--)Page : 2.4.05
Chevron
mixing tubeCF030
Cosmofin
CF010two part adhesiveCosmofin 900g
520109R DripFixing stud
TBM drip fixing rivetTBM drip 2
TB KEEP 2Security Keep
TBA 002
AWA002
wedging toolGlass packer and
Lug and air sealing adapterTS6FA - Full length adapter - 6.5m
Bead clipBCLIP 66
Run up blockTSA 010
Interlocking wedgeLWBK - BlackLWW - White
Transom Cruciform JigT6C1
TJM3Transom jig - double striptransom - TS6 302, TS6 315,TS6 316
Mullion / Transom bracket Doublestrip sections - TS6 302LH = TS6C3LRH = TS6C3R
Dummy sash clip for HL 963DSC1
TS6KTS66 keep
TS6KPKeep location packer
TS6FAC - Cut length for fixing lug - 70mm
BCLIPABead retaining clip
240
Page : 2.4.06
Sash LimitationsTS 66 ENERGY CASEMENT WINDOW SYSTEM
Revision : H (--/--/--)
GUIDE BLOCKS:Guide block to be fitted to each jamb on all tophung sashes and on bottom of all side hungsashes.Guide block to be positioned 100mm approx.from edge of sash. Position of guide blockshould not interfere with operation of hinge.
BUTT HINGES:Top hung sashes with butt hinges should not be hung from transomsections, should this occur contact AMS technical dept. for advice.
Top hung:Maximum sizes width = 1.5m (913 / 915) 1.65m (912), maximum height 1.4m.Sashes from 1.0m to 1.65m to have 3 No. fittings minimum. When utilisingcockspur handles, sashes over 1.4m high to have handles fitted to thejambs, contact AMS technical for advice on handle location.
Side hung:• Maximum sizes width = 0.7m, maximum height 1.65m.• Sashes from 1.0m to 1.65m high to have 3 No. fittings minimum.
Top Hung Locking:Cockspur handles:Sash widths from 1.0 to 1.6m, 2 handles required.
Espagnolette Locking :Espag locks to be used on vents with widthsgreater than 1.6m and heights less than 1.4m
Multipoint locking :Multipoint locking to be used on vents over 1.4mhigh use sash reference TS6 912
Side Hung Locking:Cockspur handles:Sash heights from 0.8 to 1.4m, 2 handles required.
Espagnolette Locking :Espag locks to be used on vents with heightsgreater than 1.4m.
INTERLOCKING WEDGE Ref LWBK / LWWK :Top hung:A. Up to 1.0m wide: 2 No. interlocks, 1 in 50mm from
each end.B. 1.0m to 1.6m wide: 3 No. interlocks, 1 in the centre and
1 in 50mm from each end.
Side hung:A. Up to 1.0m high: 2 No. interlocks, 1 in 50mm from
each end.B. 1.0m to 1.6m high: 3 No. interlocks, 1 in the centre and
1 in 50mm from each end.
Hinge protectors:For Q mark & security windows , fit hingeprotectors, Hinge protectros to be located within75mm of each friction stay.
Angle ofopening
Maximumweight (kg)
MaximumWidth (mm)
MaximumHeight (mm)TOP HUNG
HD 26
HD 28
2010018001600
1600 2000 100 15
Profile reference: TS6 912
Maximumweight (kg)
HD 10
TOP HUNG
6501500
HD 16 8001500
MaximumHeight (mm)
MaximumWidth (mm)
Angle ofopening
SIDE HUNG MaximumWidth (mm)
MaximumHeight (mm)
Angle ofopening
Maximumweight (kg)
34.5650 1400
42765 1550
HD 10
HD 16
Profile reference: HL 963
Profile reference: HL 963,
SIDE HUNG MaximumWidth (mm)
MaximumHeight (mm)
Angle ofopening
Maximumweight (kg)
34.5650 1530
42765 1620
HD 10
HD 16Profile reference: TS6 915, TS6 913, TS6 923,
Profile reference:TS6 915, TS6 913, TS6 923, TS6 912
Maximumweight (kg)
HD 10
TOP HUNG
7501800
HD 22 SB
HD 16 8001800
1600 1500
MaximumHeight (mm)
MaximumWidth (mm)
Angle ofopening
100 @ 20°80 @ 40° 20 & 40°
- 1500100 @ 20°80 @ 40° 20 & 40°HD 22 SB
HD 22 SB - 1500 100 @ 20°80 @ 40° 20 & 40°
50° or84°30°, 50°or 90°
50kg @ 50°40kg @ 84°100kg @ 30°55kg @ 50°50kg @ 90°
50kg @ 50°40kg @ 84°100kg @ 30°55kg @ 50°50kg @ 90°
50° or84°30°, 50°or 90°
HD 10 7501900
HD 16 8001900
50kg @ 50°40kg @ 84°100kg @ 30°55kg @ 50°50kg @ 90°
50° or84°30°, 50°or 90°
50° or 84°
30°, 50° or 90°
50° or 84°
30°, 50° or 90°
SECTION WEIGHTS:A. Allow 2.2 kg/lm for TS6 915, TS6 913 & TS6 923B. Allow 1.5 kg/lm for HL 963C. Allow 2.30 kg/lm for TS6 912
HD 28 1400 1700 100 kg 15°
SIDE HUNG MaximumWidth (mm)
MaximumHeight (mm)
Angle ofopening
Maximumweight (kg)
30.0700 1200
40.0900 1300
HD 12E
HD 16E
Profile reference:TS6 915, 913, 923, 912 & HL 963
84°
88°
HD EGRESS HINGE
Glazing options - TS202 / TS6 011Scale 1:2
Page : 2.4.07
TS 66 ENERGY CASEMENT WINDOW SYSTEM
Revision : F (--/--/--)
HL 502
8467 8468
HL 501-S
8467 846848
44
HL 506
408467 8468
HL 561
846828
TS6 20244mm glazed unit
TS6 20248mm glazed unit
TS6 20240mm glazed unit
TS6 20228mm glazed unit
8467
40
60
73
53
TILT & TURN / DOOR FRAMETS6 011
TS4 202OUTER FRAME
Glass level
Glass level
45
58
8467 30
HL 561
3813
HL 506
8467
TS6 20238mm glazed unit
Carrawedge
38
TS6 20230mm glazed unit
TS6 20235mm glazed unit
84688467
HL 565
35
32 Carrawedge
TS6 20232mm glazed unit
HL 565
14
10
28
21
16
HL 502
448467 8468
84688467
HL 501-S
48
40
HL 506
8467 8468
288467
HL 561
8468
TS6 90044mm glazed unit
TS6 90048mm glazed unit
TS6 90040mm glazed unit
TS6 90028mm glazed unit
TS6 90035mm glazed unit
Page : 2.4.08Revision : D (--/--/--)
Glazing options - TS6 900Scale 1:2
TS 66 ENERGY CASEMENT WINDOW SYSTEM
TS6 90038mm glazed unit
HL 506
8467 Carrawedge
38
8467 30
HL 561
3813
TS6 90030mm glazed unit
84688467
HL 565
35
TS6 900 no longer available
Glazing options - TS6 915Scale 1:2
TS 66 ENERGY CASEMENT WINDOW SYSTEM
Page : 2.4.09Revision : E (--/--/--)
TS6 91544mm glazed unit
44
HL 502
8467 8468
488467 8468
HL 501-S
408467 8468
HL 506
TS6 91540mm glazed unit
84688467 28
HL 561
TS6 91528mm glazed unit
TS6 91535mm glazed unit
TS6 91532mm glazed unit
TS6 91548mm glazed unit
TS6 91538mm glazed unit
HL 506
8467 Carrawedge
38
TS6 91530mm glazed unit
8467 30
HL 561
3813
84688467
HL 565
35
32 Carrawedge
HL 565
TS6 913 / TS6 923
7257
5
TS 66 ENERGY CASEMENT WINDOW SYSTEMGlazing optionsScale 1:2
Page : 2.4.10Revision : G (--/--/--)
488467 8468
HL 501
TS6 913 / 923 / 91244mm Triple glazed unit
24
24
8467
24
8467
24
8467
24
44 8468
HL 502
408468
HL 506
HL 506
Carrawedge
38
TS6 913 / 923 / 91240mm Triple glazed unit
TS6 913 / 923 / 91238mm Triple glazed unit
TS6 913 / 923 / 91248mm Triple glazed unit
8467
24
TS6 913 / 923 / 91228mm Double glazed unit
8467
24
TS6 913 / 923 / 91230mm Double glazed unit
8467
24
TS6 913 / 923 / 91232mm Double glazed unit
8467
24
TS6 913 / 923 / 91235mm Double glazed unit
8468
HL 565
35
32Carra wedge
HL 565
30
HL 561
3813
28 8468
HL 561
5
87
72
TS6 912
Note A:For use of alternative drainagearrangements please consult our technicaldepartment.
Note B:Slots and drainage holes to be staggeredby 150mm minimum
Note C:Cavity separator under sash used for ratedwindows - optional on standard windows.
At each end of the transom, notch anextra 6 x 8mm slot or drill 8mm hole toallow for extra room for drainage
20 X 25mm slot drilled thru'frame (avoid drilling strip)
20mm notch in bead hook. Bead hooknotched so it is flush with horizontalsurface of transom, seal gasket andgasket channel on sash to becompletely cut away in same locationas notch
01
02 5 x 25mm slot withdrainage cap
01
02
03
03
01
01
01
02
02
04
04
01
02
01
04
04
01
03
TS 66 ENERGY CASEMENT WINDOW SYSTEMDrainage treatmentScale NTS
Page : 2.4.11Revision : F (--/--/--)
185
01
02
05
8mm Ø drilled through sash as400mm c/c approx.
05
TS6 913 & allsash profiles
01
02
05
01
02
02
TS6 202Externally glazed
TS6 202Internally glazed
TS6 302Externally glazed
TS6 302Externally glazed
TS6 302With sash profile
TS6 302Internally glazed(Zone drain each transom)
TS6 302Internally glazed(End drain each transom)
TS6 321Externally glazed
TS6 321Externally glazed
TS6 202 / TBS 161Internally glazed
TS6 202 / TBS 151Internally glazed
TS6 202 / TS4 230
TS6 209Externally glazed
TS6 20910Internally glazed
01
01
02
02
Note A:For use of alternative drainage arrangementsplease consult our technical department.
Note B:Slots and drainage holes to be staggered by150mm minimum
Note C:Cavity separator under sash used for ratedwindows - optional on standard windows.
At each end of the transom, notch anextra 6 x 8mm slot or drill 8mm hole toallow for extra room for drainage
20 X 25mm slot drilled thru'frame (avoid drilling strip)
20mm notch in bead hook. Bead hooknotched so it is flush with horizontalsurface of transom, seal gasket onsash to be completely cut away insame location as notch
01
02 5 x 25mm slot withdrainage cap
03
04
TS 66 ENERGY CASEMENT WINDOW SYSTEMDrainage treatmentScale NTS
Page : 2.4.12Revision : E (--/--/--)
8mm Ø drilled through sash as400mm c/c approx.
05
01
01
01
01
05
05
05
02
02
02
02
04
04
04
04
01
03
TS6 302 / TBS 151Sash reverser
TS6 302 / TBS 151Sash reverser
TS6 302 / TBS 151Sash reverser
02TS6 202 / TBS 151Sash reverser
01
02
01
02
05
TS6 302 / TBS 161Rebate reverser
TS6 302 / TBS 161Rebate reverser
TS6 302 / TBS 161Rebate reverser
TS6 202 / TBS 161Rebate reverser
TS 66 ENERGY CASEMENT WINDOW SYSTEMInternally beaded optionsSash reverser / Rebate reverser locationsScale NTS
Page : 2.4.13Revision : B (--/--/--)
RR - Rebate reverser - TBS 161SR - Sash reverser - TBS 151
RR
Rebate reverser or Sashreverser
SR
SR
RR Rebate reverser or Sashreverser
Rebate reverser or Sashreverser
Rebate reverser or Sashreverser
SR
SR
Note:Sash for internally beaded optionsTS6 913, TS6 923 or TS6 911
Equal leg frame with standard sash TS6202 - TS6900Scale 1:2
Page : 2.4.14
02
03
05
06
08
02
03
06
05
07
08
07
0104
01 04
TS 66 ENERGY CASEMENT WINDOW SYSTEM
Revision : D (--/--/--)
TS6 202
TS6 900HL 561
28
TS6900
36
HL 561
28
TS6FA
TS6FA
36
HL 561
28
TS6FA
TS6FA
HL 561
HL 561HL 561
HL 561
HL 561
TS6F
A
HL
561
36
28
HL 561
3362
95
605
81
60
45
28
40
7636
148
322 76
112
96
6096
110
HL 561
28
TS6FAUnequal leg optionTS6 321
5675
TS6 202 TS6 321
TS6 30276
TS6 302
TS6 302
TS6 900 no longer available
Revision : E (--/--/--)Page : 2.4.15
TS6 202 With TS 915 (fixed light externally beaded)Scale 1:2
01
03 04
05
02
TS 66 ENERGY CASEMENT WINDOW SYSTEM
01
02
03
8468
TS6 915
TS6 202
TS6 915
TS6 915
TS6 600Option with drain tray
7
4141
7
TS6FA
04
TS6FA
HL 561
60
45
28
40
TS6FA
101
60
HL 561
HL 561
28
HL 561
76 159
41
TS6FA
TS6 202
60
HL 561
28
HL 56128
HL 56128
04
04
5675
92
60
TS6 302
TS6 321
TS6 202 TS6 202
05
TS6
915
HL
561TS
6 91
5
HL
561
28
50
67 22 67
TS6 315
TSCS2
Note:As an optional extra, the cavityseparator (TSCS2) can be fittedbetween the sash and the frame so asto improve the thermal performance ofthe window.
01
02
03
05
04
0809 07
Page : 2.4.16Revision : D (--/--/--)
TS6 202 with HL 963 (slim line tee sash)Scale NTS
TS 66 ENERGY CASEMENT WINDOW SYSTEM
06
TS6 FA - Optional01
02
03
HL 963 HL 561
HL 963
HL 563
TS6 302
TS6 202
HL 963
HL 561
HL 963
HL 563
TS6 302
TS6 202
28
HL 963
TS6 2023352
85
HL 963
5222
52
126
85
Dummy sash clipfitted aroundfixed panes
04
05
06
2460
2576
2485
12685 85
TS6 202 TS6 202TS6 315
HL 963 HL 963 HL 963 HL 963
HL 561 HL 561
HL 563HL 563
HL 561 HL 561 HL 561 HL 561
070809
HL 963
HL 963
F/P
F/P F/P
S/H
F/P - Fixed paneS/H - Sash
Dummy sash clipfitted aroundfixed panes
TSCS2
Note:As an optional extra, thecavity separator (TSCS2)can be fitted between thesash and the frame so asto improve the thermalperformance of thewindow.
Revision : E (--/--/--)Page : 2.4.17
TS6 202 With TS6 913 (fixed light externally beaded)Scale 1:2 01
02
03 04
05
TS 66 ENERGY CASEMENT WINDOW SYSTEM
02
03
05TS6 913
TS6 913
TS6 315
TS6 913
725
7
7
72
45
72
288467 8468
HL 561
TS6FA
HL 56128
TS6 202
TS6FA
60HL 561
2804
50
HL 561
28
288467 8468
HL 561
28
8467
8468
TS6 202
TS6 600Option with drain tray
TS6FA or TS6FAC
04
TS6FA
HL 561
60
45
28
40
HL 56128
HL 56128
04
045675
92
60
66
4476
120
TS6 302
TS6 202
28
24
120
TS6 321
TSCS2
Note:As an optional extra, the cavityseparator (TSCS2) can be fittedbetween the sash and the frame so asto improve the thermal performance ofthe window.
Page : 2.4.18Revision : F (--/--/--)
TS6 202 With TS6 912 (fixed light externally beaded)Scale 1:2
03 04
05
02
01
TS 66 ENERGY CASEMENT WINDOW SYSTEM
TS6 202
TS6 600Option with drain tray
TS6FA
04
TS6FA
HL 561
60
4540
HL 56128
HL 56128
04
04
5675
92
60
02
03
TS6 315
7
TS6FA
HL 56128
TS6 202
TS6FA
60
HL 56128
04
50
HL 561
28
66
76
TS6 302
TS6 202
28
24
TS6 912
128
8467 WedgeCarra
TS6 912
8467 Wedge
Carra
TS6 912
8467
WedgeCarra
48 87135
554
05
5
54
120
33
60
28
TS6 321
Option with un-equal leg frame
TSCS2
Note:As an optional extra, the cavityseparator (TSCS2) can be fittedbetween the sash and the frame so asto improve the thermal performance ofthe window.
28
28
28
01
02
03
05
04
0809 07
Page : 2.4.19Revision : E (--/--/--)
TS6 202 with TS6 913 (Internally beaded window using TBS 161)Scale NTS
TS 66 ENERGY CASEMENT WINDOW SYSTEM
TS6 913
TS6 202
HL 561
HL 562
TBS 161
HL 562 HL 562
TBS 161
HL 562
TBS 161
06
HL 562
TBS 161
TS6 202
HL 561
TS6 913
TS6 315
HL 561
TBS 161
TS6 202
TS6 FA - Optional
HL 561
TS6 302
TS6 913
HL 561
HL 561
TS6 913
TS6 202
TBS 161
TBS 161
TBS 161
TS6 302
TS6 202
TS6 202
HL 562
HL 562
HL 562
3937
76
3372
105
7222
72
167
108
105
1377265
50
28
105
01
02
03
04
05
06
0910
07
08
0910
TS6 315
TSCS2
Note:As an optional extra, the cavityseparator (TSCS2) can be fitted betweenthe sash and the frame so as to improvethe thermal performance of the window.
04
05
03
01
02
03 03
05
04
06
08 09
07 0607
0809
TS6 202
TS6 202
01
TS6 913
TBS 151
TS6 302
TBS 151
32
TS6 302
TBS 151TBS 151
REVERSER MULLIONTS6 319
TS6 202
Page : 2.4.20Revision : D (--/--/--)
TS6 202 with TS6 913 (Internally beaded window using TBS 151)Scale NTS
TS 66 ENERGY CASEMENT WINDOW SYSTEM
TS6 202
141
6972
53
4040
44
125
TS6 202
TS6 913
60
72 69141
76
50
36
66
7660
125
02
06 07
08 0960
TSCS2
Note:As an optional extra, the cavity separator(TSCS2) can be fitted between the sashand the frame so as to improve thethermal performance of the window.
TS6 912 sash with security gearScale 1:2
Page : 2.4.21
TS 66 ENERGY CASEMENT WINDOW SYSTEM
Revision : F (--/--/--)
0403
02
01
VIEW FROM INSIDE
02
01
0304
Titon or Prolineaespag handle
TS6 912
TS6 912TS6 202
TS6FA
120
33
60
TS6F
A
HL 561 TS6 912TS6 202
TS6F
A
HL 561TS6 202
TS6F
A
TS6 202
TS6FA
60TS6 912
119
TSCS2
Note:As an optional extra, the cavityseparator (TSCS2) can be fittedbetween the sash and the frameso as to improve the thermalperformance of the window.
288467 8468
HL 561
288467 8468
HL 561
28
8467
8468
28
28
Transom options & Add on detailsScale 1:2
Page : 2.4.22
TS 66 ENERGY CASEMENT WINDOW SYSTEM
Revision : C (--/--/--)
TS6 080
TS6 08080mm extenderFor extra height on width orjambs or for fitting slotvents to the head of awindow
90mm TransomTS6 390
100mm TransomTS6 340
80
90 100
50
TS6 08580mm extenderFor extra height onwidth or jambs
TS6 085
TS6 30276mm Transom
76
TSCS2
Note:As an optional extra, the cavityseparator (TSCS2) can be fittedbetween the sash and the frame so asto improve the thermal performance ofthe window.
66
TS6 084140mm extenderFor extra height on width orjambs or for fitting slotvents to the head of awindow
140
TS6 084
Detail into brick / blockwork.Scale NTS
Page : 2.4.23
TS 66 ENERGY CASEMENT WINDOW SYSTEM
Revision : C (--/--/--)
Membrane Clamped to backof lug adapter and bondedback to structure (Air seal)
Fixings to besuitable forintended use.
Continuous LM sealFoam fillinsulation orsimilar to avoidcold bridging
Membrane Clamped to backof lug adapter and bondedback to structure (Air seal)
Membrane Clamped to backof lug adapter and bondedback to structure (Forweather seal)
Window fixed to structurewith fixing straps at 600mmc/c max (See drawing 2.4.28for more detailed instructionon fitting)
TS6202
TS6202
TSCS2
Note:As an optional extra, thecavity separator (TSCS2) canbe fitted between the sashand the frame so as toimprove the thermalperformance of the window.
Add on detailsScale NTS
Page : 2.4.24
TS 66 ENERGY CASEMENT WINDOW SYSTEM
Revision : F (--/--/--)
Fixing lugdetail
3821 gasketfitted to sealfor extraweathering Continuous
l.m. siliconeseal
FRAME TO TS CILL (TS4 230)
TS CILL
TB6 802
TS6 202
TS Drain trayTS6 600
18
33
TS6 202
90 degree corner post TB6 802
Ixx = 13.85 cm4In line Coupler - TS6 350
50
50mm coupler - TS6 351Ixx = 69.63 cm4
66
End cap for TS4 230(TSA 030 - Standard)(TSA 031 - with drip piece)
l.m. seal
l.m. seal
l.m. seal
4
52452
125
9030
59
60 60
l.m. seal
l.m. seal
459 59
100
Ixx = 249 cm4100mm coupler - TS6 352
l.m. seal
l.m. seal
459 59
TS6 353100mm slim COUPLERIxx = 185.65 cm4Iyy = 7.38 cm4
XT6 800Bay pole detail, suitable forangles between 115 to 180°
XT6 810Fillet
XT6 811Packer
115°
Revision : F (--/--/--)Page : 2.4.25
Butt hinge optionsScale NTS
TS 66 ENERGY CASEMENT WINDOW SYSTEM
TS butthinge
Note 1:When fitting the TS butt hinge to atransom, move the drip section so asthe drip does not interfere with thehinge
Note 2:The TS butt hinge is not suitablewhere the is a sash over a sash. thespace between sashes will not allowfitting of the hinge
21
TS6FA
Crest hinge
Crest hinge
TS6 202
TS6 915
TS6 202
TS6 202
TS6 202
TS6 915
TS6 913
TS6 912
TSCS2
Note:As an optional extra, the cavityseparator (TSCS2) can be fitted betweenthe sash and the frame so as to improvethe thermal performance of the window.
TS butthinge
Curtain wall insert detailsScale 1:2
Page : 2.4.26
TS 66 ENERGY CASEMENT WINDOW SYSTEM
Revision : D (--/--/--)
HL 963HL 563
HL 561
28
TS6 915
HL 963
TS6 913
TS6 912
TS6 209TS6 209
TS6 209
96
5799
113
11
11
11
11
76
HL 561
HL 56128 TS6 302
HL 56128
HL 56128
HL 561
28
Revision :Page : 2.4.27
XT6 200 With TS6 913 (fixed light externally beaded)Scale 1:2
TS 66 ENERGY CASEMENT WINDOW SYSTEM01
02
03 04
05
XT6 200
52
66
TS6 302
XT6 200
52
52
66
XT6 200
18
52
3385
XT6 200
TS6 600
TS6 913
72
288467 8468
HL 561
97
02
TS6 913
72
288467 8468
HL 561
4412
0 05
TS6 913
TS6 315
7
4550
HL 561
28
28
8467
8468
28
24
120
01
03 04
04
HL 56128
52
66
XT6 200
04XTDRIP
TSCS2
Note:As an optional extra, the cavityseparator (TSCS2) can be fittedbetween the sash and the frame so asto improve the thermal performance ofthe window.
Detail into brick / blockwork.Scale 1:2
Page : 2.4.28
TS 66 ENERGY CASEMENT WINDOW SYSTEM
Revision :
Membrane Clamped toback of lug adapter andbonded back tostructure (Air seal)
Membrane Clamped into lugadapter and bonded back tostructure (For weather seal)
100m
m m
in.
125
± 25
600
max
125
± 25
125
± 25
125 ± 25
125
± 25
Fixing distances for aluminium windows and doors as per BS 8213-4:2007Wherever practicable all four sides of the frame should be secured as follows:
1. Corner jamb fixings should be between 100mm and 150mm from the external corner2. No fixings should be less than 100mm from the centre line of a mullion or transom3. Intermediate fixings should be at centres no greater than 600mm4. There should be a minimum of two fixings on each jamb.5. On windows over 1800mm wide, central head and sub sill fixings should be provided.
Alternatively, apply a suitablesilicone sealant around theperimeter of the frame andstructure (on the outside).
TSCS2
Note:As an optional extra, thecavity separator (TSCS2)can be fitted between thesash and the frame so as toimprove the thermalperformance of the window.
TS 66 ENERGY CASEMENT WINDOW SYSTEMGlazingScale NTS
Page : 2.4.29Revision : C (--/--/--)
Indicates spacer onlyIndicates load bearing packer
Fixedpane
Sidehung
Tophung
Note: Load bearing packers to belocated close to gearing points,typically 160mm from edge.
Standard 5mmpvc glass packer
11
Standard11mm pvcglass packer
Standard 5mm pvcglass packer
Standard 5mm& 4mm pvcglass packer
TS6 202
5
5
5
TS6 915
TS6 913
TS6 912
TS6 202
TS6 202
TS6 202
Notes:1. Ensure glass packers do not cover
drainage slots and holes.2. Silicone should not be used when fitting
glass packers as excessive amounts mayhinder drainage.
3. Packers to be of suitable material and fitfor purpose.
4. Refer to BS 8213-4:2007, BS 6262 & BS8000-7 for further recommendations.
5. In addition to the above any glass orinsulating glass unit manufacturer'sinstructions should be followed.
TS6 202 With TS6 923 (fixed light externally beaded)Scale 1:2 01
02
03 04
05
TS 66 ENERGY CASEMENT WINDOW SYSTEM
02
05TS6 923
TS6 913
TS6 302
7
72
45HL 561
28
TS6 202
60HL 561
2801
HL 561
28
288467 8468
HL 561
28
8467
8468
TS6 202
TS6 600Option with drain tray
HL 56128
04
92
60
66
4476
120
TS6 302
120
TS6 202
TS6 600Option with drain tray
92
60772
288467 8468
HL 561
Page : 2.4.30Revision :
03
TSCS2
Note:As an optional extra, the cavityseparator (TSCS2) can be fittedbetween the sash and the frame so asto improve the thermal performance ofthe window.
TS6FA
04
TS6FA
HL 561
60
4540
HL 56128
04
5675
28
TS6 321
Option with un-equal leg frame
TS 66 ENERGY CASEMENT WINDOW SYSTEMCill Options without dripScale NTS
Page : 2.4.31Revision : A (--/--/--)
CILLE60Cill Extender
145
100
60
30
170
230
XT6260Riser section
XT6260Riser section
XT6260Riser section
XT6260Riser section
XT6260Riser section
XT6260Riser section
CILL170170mm Cill
CILL100100mm Cill
CILL06060mm Cill
CILL145145mm Cill
CILL03030mm Cill
XT6260Riser section
CILL120120mm Cill
120
CILLEC230SCill end cap
CILLEC145SCill end cap
CILLEC120SCill end cap
CILLEC100SCill end cap
CILLEC060SCill end cap
CILLEC030SCill end cap
28
CILL200200mm Cill
200
CILLEC200SCill end cap
CILLEC170SCill end cap
TS 66 ENERGY CASEMENT WINDOW SYSTEMCill Options with dripScale NTS
Page : 2.4.32Revision : A (--/--/--)
CILLE60Cill Extender
170
145
100
60
30
170
230
XT6260Riser section
CILL170170mm Cill
CILL170170mm Cill
CILL100100mm Cill
CILL06060mm Cill
CILL145145mm Cill
CILL03030mm Cill
CILL120120mm Cill
120
CILLEC170DCill end cap
CILLEC145DCill end cap
CILLEC120DCill end cap
CILLEC100DCill end cap
CILLEC060DCill end cap
CILLEC030DCill end cap
Drip15Drip section
CILLEC230DCill end cap with drip
15
Drip1515mm Dripsection
28