Post on 28-Nov-2021
RAILROAD COMMISSION OF TEXAS Oil and Gas Division
API No. 42- 7. RRC District No.
8. RRC Lease No. Oil Well Potential Test, Completion or Recompletion Report, and Log
LIN (WOLFCAMP) UNIVERSITY EAST
EP ENERGY E&P COMPANY, L.P. 253385
4412VH
ATTN CHELSEA CHAPMAN PO BOX 4660 HOUSTON, TX 77210-4660
12 , 44 , UL , A-U391 20 MILES NW DIRECTION FRO OZONA
Initial Potential
Reclass
(Explain In remarks)Well record only
Retest
11. Purpose of filing
6b. Distance and direction to nearest town in this county.6a. Location (Section, Block, and Survey)
4. ADDRESS
9. Well No.
RRC Operator No.3. OPERATOR'S NAME (Exactly as shown on Form P-5, Organization Report)
2. LEASE NAME1. FIELD NAME (as per RRC Records or Wildcat)
17576
7C105-41873
CROCKETT10. County of well site
5. If Operator has changed within last 60 days, name former operator
X
This facsimile W-2 was generated electronically from data submitted to the RRC.
Tracking No.: 98125Status: Submitted
12. If workover or reclass, give former field (with reservoir) & Gas ID or oil lease no.FIELD & RESERVOIR
GAS ID or OIL LEASE #
Oil-0 Gas-G Well #
N/A
13. Type of electric or other log run 14. Completion or recompletion date
Gamma Ray (MWD) 01/25/2014
SECTION I- POTENTIAL TEST DATA IMPORTANT: Test should be for 24 hours unless otherwise specified infield rules. 15. Date of test 16. No. of hours tested 17. Production method (Flowing, Gas Lift, Jetting, Pumping- Size & Type of pump) 18. Choke size
02/06/2014 24 Flowing 38/128
Oil - BBLS
Oil - BBLS
Gas - MCF
Gas - MCF
Water - BBLS
Water - BBLS Gas - Oil Ratio
Oil Gravity-API-60 o
Flowing Tubing Pressure
PSI
PSI
Casing Pressure
21. Was swab used during this test? 22. Oil produced prior to test (New & Reworked wells) 23. Injection Gas-Oil RatioYes No
19. Production during Test Period
20. Calculated 24- Hour Rate
596.0 1168 2717 1959 725.0
596.0 1168 2717 39.2 0.0
X 270.0REMARKS: N/A
INSTRUCTIONS: File an original and one copy of the completed FormW-2 in the appropriate RRC District Office within30 days after completing a well and within 10 days after a potential test. If an operator does not properly report theresults of a potential test within the 10-day period, the effective date of the allowable assigned to the well will not extendback more than 10 days before the W-2 was received in the District Office. (Statewide Rules 16 and 51) To report acompletion or recompletion, fill in both sides of this form. To report a retest, fill in only the front side.
WELL TESTERS CERTIFICATIONI declare under penalties prescribed in Sec. 91.143, Texas Natural Resources Code, that I conducted or supervised this test by observation of (a) meterreadings or (b) the top and bottom gauges of each tank into which production was run during the test. I further certify that the potential test data shownabove is true, correct, and complete, to the best of my knowledge.
Signature: Well Tester Name of Company RRC Representative
OPERATOR'S CERTIFICATIONI declare under penalties prescribed in Sec. 91.143, Texas Natural Resources Code, that I am authorized to make this report, that this report was preparedby me or under my supervision and direction, and that data and facts stated therein are true, correct and complete, to the best of my knowledge.
Telephone: Area Code Number Month Day Year Signature
Title of PersonType or printed name of operator's representativeRegulatory Analyst
(713) 997-5138 02/24/2014
EP ENERGY E&P COMPANY, L.P.
LINDA RENKEN
DATA ON WELL COMPLETION AND LOG (Not Required on Retest)SECTION III
24. Type of Completion
New Well Deepening Plug Back Other
26. Notice of Intention to Drill this well was filed in Name of
DATE
PERMIT NO.
PERMIT NO.
PERMIT NO.
PERMIT NO.
CASE NO.
Other
Commenced Completed
31. Location of well, relative to nearest lease boundaries Feet From
Line of the
Line and Feet from
Lease
32. Elevation (DF. RKB, RT. GR ETC.) 33. Was directional survey made otherthan inclination (Form W-12)? Yes No
34. Top of Pay 35. Total Depth 36. P. B. Depth Dt. of Letter
Dt. of Letter
PermitWater Injection
PermitSalt Water Disposal
ExceptionRule 37DeepenPlug Back or
25. Permit to Drill,
Railroad Commission (Special)
Recommendation of T.D.W.R.
Same Lease &Reservoir30. Distance to nearest well,
in this lease28. Total number of acres
this field (reservoir) including this well27. Number of producing wells on this lease in
Operations:Workover or Drilling
29. Date Plug Back, Deepening,
Determined by37. Surface Casing
RulesField
38. Is well multiple completion?
Yes No
X
EP ENERGY E&P COMPANY, L.P.
96 50621.975
10/12/2013 12/04/2013 383.0
13415.0 South 15858.0West UNIVERSITY EAST
2703 GLX
MD:15228
X
76905208/30/2013
X 09/10/20137140 MD:15279
39. If multiple completion, list all reservoir names (completions in this well) and Oil Lease or Gas ID No.FIELD & RESERVOIR
GAS ID or OIL LEASE #
Oil-0 Gas-G Well #
N/A40. Intervals Drilled by:
RotaryTools
CableTools
41. Name of Drilling Contractor
Yes No
42. Is Cementing Affidavit Attached?
TYPE & AMOUNT CEMENT (sacks)
CASING RECORD (Report All Strings Set in Well)
SLURRY VOL. cu. ft.
HOLE SIZEDEPTH SETCASING SIZE WT #/FT. MULTISTAGETOOL DEPTH
TOP OFCEMENT
43.
XX
9039 5/8 CLASS C 460 12 1/4 0 934.7152795 1/2 CLASS H 2375 8 3/4 754 3882.0
LINER RECORD44.
Size Top Bottom ScreenSacks Cement
N/A
45. TUBING RECORD 46. Producing Interval (this completion) Indicate depth of perforation or open hole
From L1 7403Packer SetSize Depth Set To 15184 From70622 7/8 7079 ToFrom ToFrom To
47. ACID, SHOT, FRACTURE, CEMENT SQUEEZE. ETC.
Depth Interval Amount and Kind of Material Used
7403.0 15184.0 ADD PERFS W/3-1/8" GUN, 6 SPF, 60 DEGREE PHASE (30 SETS). FRAC 30 STAGES (SEE FRACFOCUS FOR DETAILS).
FORMATION RECORD (LIST DEPTHS OF PRINCIPAL GEOLOGICAL MARKERS AND FORMATION TOPS)48.
Formations FormationsDepth Depth
WFMPC (WOLFCAMP C) 6901.0 MD: 6938.0WFMPC1 7003.0 MD: 7064.0WFMPC_TOP_LZ 7073.0 MD: 7184.0REMARKS: UNIVERSITY EAST 4412VH. KOP = 6688'. AS DRILLED PLAT HAS BEEN REQUESTED AND WILL BE SUBMITTED ONCE RECEIVED.
RAILROAD COMMISSION OF TEXASOil and Gas Division
FORM L-1 ELECTRIC LOGSTATUS REPORT
Instructions
When to File Form L-1: Where to File Form L-1:� with the appropriate Commission district office� with Forms G-1, W-2, and GT-1 for new and deepened gas, oil, and
geothermal wells
� with Form W-3 for plugged dry holes� when sending in a log which was held under a request for confidentiality and the period for confidentiality has not yet expired.
Filling out Form L-1:� Section I and the signature section must be filled out for all wells� complete only the appropriate part of Section II
Type of log required:When is Form L-1 NOT required:
� with Forms W-2, G-1, and GT-1 filed for injection wells, disposal wells, water supply wells, service wells, re-test wells, re- classifications, and plugbacks of oil, gas or geothermal wells� with Form W-3 for plugging of other than a dry hole
� any wireline survey run for the purpose of obtaining lithology, porosity, or resistivity information� no more than one such log is required but it must be of the subject well� if such log is NOT run on the subject well, do NOT substitute any other type of log; just select Section II, Part A below
This facsimile L-1 was generated electronically from data submitted to the RRC.
SECTION I. IDENTIFICATIONOperatorName:
District No.
CompletionDate:
Drilling PermitNo.
FieldName
LeaseName
County
Lease/IDNo.
WellNo.
API
No. 42-SECTION II. LOG STATUS (Complete either A or B)
7C 01/25/2014
CROCKETT
769052LIN (WOLFCAMP)
EP ENERGY E&P COMPANY, L.P.
UNIVERSITY EAST 17576 4412VH
105-41873
A. BASIC ELECTRIC LOG NOT RUN
B. BASIC ELECTRIC LOG RUN. (Select one)
1. Confidentiality is requested and a copy of the header for each log that has been run on the well is attached.
2. Confidentiality already granted on basic electric log covering this interval (applicable to deepened wells only).
3. Basic electric log covering this interval already on file with Commission (applicable to deepened wells only).
4. Log attached to (select one):
(a) Form L-1 (this form). If the company/lease name on log is different from that shown in Section I, please enter name on log here:
Check here if attached log is being submitted after being held confidential.
(b) Form P-7, Application for Discovery Allowable and New Field Designation.
(c) Form W-4, Application for Multiple Completion:
Well No(s).
Signature Title
Name (print) Phone Date
-FOR RAILROAD COMMISSION USE ONLY-
X
X
X
02/24/2014
Lease or ID No(s).
Regulatory Analyst
(713) 997-5138
LINDA RENKEN
EP ENERGY E&P COMPANY, L.P.
Tracking No.: 98125
STATEMENT OF PRODUCTIVITY OF ACREAGE ASSIGNED TO PRORATION UNITS Form P-15
The undersigned states that he is authorized to make this statement; that he has knowledge of the
OPERATOR
LEASE
,
, No.WELL
facts concerning the
; that such well is
completed in the Field, County,
Texas and that the acreage claimed, and assigned to such well for proration purposes as
authorized by special rule and as shown on the attached certified plat embraces
acres which can reasonably be considered to be productive of hydrocarbons.
- CERTIFICATE -
I declare under penalties prescribed in Sec. 91.143, Texas Natural Resources Code, that I am autho-rized to make this report, that this report was prepared by me or under my supervision and direction,and that data and facts stated therein are true, correct, and complete, to the best of my knowledge,
Date 02/24/2014 Signature LINDA RENKEN
Telephone (713) 997-5138
AREA CODETitle Regulatory Analyst
EP ENERGY E&P COMPANY, L.P.
UNIVERSITY EAST 4412VH
CROCKETT
260.0
LIN (WOLFCAMP)
This facsimile P-15 was generated electronically from data submitted to the RRC.
Tracking No.: 98125