Post on 06-Apr-2018
8/3/2019 5500 Series Copy
1/24
USSC 1
King/Ashley Pellet Stove
Please read this entire manual before installation and use of this appliance. Failure to followthese instructions could result in property damage, bodily injury, or even death.
Contact your local building or re ofcials about restrictions and installation inspectionrequirements in your area.
Save these instructions.
Owners Manual
UNITED STATES STOVE COMPANY 227 INDUSTRIAL PARK ROAD SOUTH PITTSBURG, TENNESSEE 37380 WWW.USSTOVE.COM
FOR TECHNICAL ASSISTANCE: PHONE: (800) 750-2723 FAX: (423) 837-2109
Part No.: 851641
UNITED STATES STOVE COMPANYKeeping North America Warm Since 1869
models 5500/5500M/5500XL
CSSUCOMPANY
UNI
TEDSTATESSTOVE
5500M
5500XL
5500
E
8/3/2019 5500 Series Copy
2/24
2 USSC
TABLE OF CONTENTS ..............................................................................................2
SAFETy PrECAuTiONS ...........................................................................................3
SPECiFiCATiONS .......................................................................................................4
HeatingSpecications .....................................................................................4
Dimensions ......................................................................................................4
ElectricalSpecications ...................................................................................4 FuelConsiderations.........................................................................................4
SafetyandEPACompliance............................................................................4iNSTALLATiON ..........................................................................................................5
InstallationOptions ..........................................................................................5
FloorProtection ...............................................................................................5
Clearances......................................................................................................6
VentingRequirements .....................................................................................7
MaximumVentingDistance .............................................................................7
PelletVentType...............................................................................................7
PelletVentInstallation .....................................................................................7
PelletVentTermination ....................................................................................7
VentTerminationClearances...........................................................................8
ThroughtheWallInstallation ...........................................................................9
ThroughtheRoof/CeilingInstallation...............................................................9
OutsideAirSupply .........................................................................................10
SpecialMobileHomeRequirements .............................................................10uNdErSTANdiNg yOur STOvE ...........................................................................11
CONTrOL PANEL OvErviEw ................................................................................12
OPErATiON ........................................................................................................13-15
UnitPreparation.............................................................................................13
PerformingInitialTest ....................................................................................13
PerformingaDryRun..................................................................................13
Start-UpProcedure........................................................................................14 ShutDownProcedure....................................................................................14
DailyOperation ..............................................................................................15
SafetyandConvenienceFeatures ................................................................15MAiNTENANCE ...................................................................................................15-16
ExhaustSystem.............................................................................................15
InteriorChambers ..........................................................................................16
AshDisposal..................................................................................................16
CheckandCleantheHopper ........................................................................16
MainDoorGaskets ........................................................................................16
BlowerMotors................................................................................................16
PaintedSurfaces ...........................................................................................16
Glass..............................................................................................................16Fall Start-Up ...................................................................................................16
SpringShutDown..........................................................................................16
YearlyServicing .............................................................................................16TrOuBLE ShOOTiNg .............................................................................................17
ErrOr COdES & diSPLAy iNdiCATOrS .............................................................18
rEPAir PArTS diAgrAM/LiST ........................................................................19-21
wiriNg diAgrAM ...................................................................................................22
Table of Contents
8/3/2019 5500 Series Copy
3/24
USSC 3
Safety Precautions
IMPORTANT:Readthisentiremanualbeforeinstalling
and operating thisproduct. Failure todo somay
resultinpropertydamage,bodilyinjury,orevendeath.
Properinstallationofthisstoveiscrucialforsafeand
efcientoperation.
Install ventat clearancesspecifiedby the vent
manufacturer.
Donotconnectthepelletventtoaventservingany
otherapplianceorstove.
Donotinstall auedamper intheexhaustventing
systemofthisunit.
Useofoutsideairisnotrequiredforthisunit.
Contact yourlocal building officialsto obtaina
permitand informationonanyadditionalinstallation
restrictionsorinspectionrequirementsinyourarea.
Donot throw thismanualaway. Thismanualhas
importantoperating andmaintenance instructionsthatyouwillneedatalatertime.Alwaysfollowthe
instructionsinthismanual.
This
meet or exceed the standard set by the Pellet
Institute(PFI). The use of other fuels will void
Neveruse gasoline, gasoline-typelantern fuel,
kerosene,charcoallighteruid,orsimilarliquidsto
startorfreshenupareinthisstove.Keepallsuch
liquidswellawayfromthestovewhileitisinuse.
Aworkingsmokedetectormustbeinstalledinthesame
roomasthisproduct.
Donotunplugthestoveifyoususpectamalfunction.
TurntheON/OFFSWITCHtoOFFandcontactyour
dealer.
Yourstoverequiresperiodicmaintenanceandcleaning
(seeMAINTENANCE).Failuretomaintainyourstove
mayleadtoimproperand/orunsafeoperation.
Disconnectthe power cordbeforeperforming any
maintenance!NOTE:TurningtheON/OFFSwitchto
OFFdoesnotdisconnectallpowertotheelectrical
componentsofthestove.
Nevertrytorepairorreplaceanypartofthestoveun -
lessinstructionsfordoingsoaregiveninthismanual.
Allotherworkshouldbedonebyatrainedtechnician.
Donotoperateyour stovewith theviewing door
open.Theaugerwillnotfeedpelletsunderthese
circumstancesandasafetyconcernmayarisefrom
sparksorfumesenteringtheroom.
Allow thestove to coolbefore performing any
maintenanceorcleaning.Ashesmustbedisposed
inametalcontainerwithatightttinglid.Theclosed
container ofashes should beplacedon a non
combustiblesurfaceorontheground,wellawayfrom
allcombustiblematerials,pendingnaldisposal.
Theexhaustsystemshouldbecheckedmonthlyduringtheburningseasonforanybuild-upofsootorcreosote.
Donottouchthehotsurfacesofthestove.Educateal
childrenonthedangersofahigh-temperaturestove
Youngchildrenshouldbesupervisedwhentheyare
inthesameroomasthestove.
Thehopperandstovetopwillbehotduringoperation
therefore,youshouldalwaysusesometypeofhand
protectionwhenrefuelingyourstove.
Apowersurgeprotectorisrequired.Thisunitmus
bepluggedintoa 110- 120V,60 Hzgrounded
electricaloutlet.Donotuseanadapterplugorsevethegroundingplug.Donotroutetheelectricalcord
underneath,in frontof,or over theheater. Dono
routethecordinfoottrafcareasorpinchthecord
underfurniture.
Theheaterwillnotoperateduringapoweroutage.Ifa
poweroutagedoesoccur,checktheheaterforsmoke
spillageandopenawindowifanysmokespillsinto
theroom.
Thefeeddoormustbeclosedandsealedduring
operation.
Neverblockfreeairowthroughtheopenventsotheunit.
Keepforeignobjectsoutofthehopper.
Themovingpartsofthisstovearepropelledbyhigh
torqueelectricmotors.Keepallbodypartsawayfrom
theaugerwhilethestoveispluggedintoanelectrica
outlet.Thesemovingpartsmaybegintomoveatany
timewhilethestoveispluggedin.
Donotplaceclothingorotherammableitemsono
nearthisstove.
Wheninstalledinamobilehome,thestovemusbegroundeddirectlyto thesteelchassisandbolted
to theoor. WARNINGTHISUNITMUSTNOT
BE INSTALLED INTHE BEDROOM (perHUD
requirements). CAUTIONTHESTRUCTURAL
INTEGRITYOFTHEMOBILEHOMEFLOOR,WALL,
ANDCEILING/ROOFMUSTBEMAINTAINED.
Thisapplianceisnotintendedforcommercialuse.
*Thisapplianceisafreestandingheater.Itisnotintendedtobeattachedtoanytypeofducting.Itisnotafurnace.
8/3/2019 5500 Series Copy
4/24
4 USSC
Specifcations
HeatOutput1 48,000BTU/hr.
Heating Capacity2 800-2,000sq.ft.
Fuel Burn Rate3 2.0-6.0lbs./hr.
BurnTime(lowestsetting) 5500/5500M-60hrs. 5500XL -160hrs.HopperCapacity 5500/5500M-150lbs. 5500XL-320lbs.
Heating Specications
5500/5500M 5500XL
Height 34in. 471/4in.
Width 26 in. 26 in.
Depth
25 in. 25 in.Weight 250lbs. 275lbs.
Dimensions
1BTUoutputwillvarydependingonthequalityoffuel.UsePFIlistedfuelsforthebestresults.2Heatingcapacitywillvarydependingonoorplanlayoutofyourhome,degreeofinsulation,andtheoutsidetemperature.3Pelletsizemayeffecttheactualrateoffuelfeedandburntimes.Fuelfeedratesmayvarybyasmuchas20%.UsePFIlistedfuelforbestresults.
Electrical Rating 110-120volts,60HZ,3.0Amps
Watts(operational) 175(approx.)
Watts(igniterrunning) 425(approx.)
Eectrica Specications
FuEL CONSidErATiONS
YourKing/Ashley stove isdesignedtoburnpremiumhardwoodpelletsthatcomplywithAssociationofPelletFuel
Industriesstandards.(Minimumof40lbsdensitypercubicft,1/4to5/16diameter,lengthnogreaterthan1.5,notless
than8,200BTU/lb,moistureunder8%byweight,ashunder1%byweight,andsaltunder300partspermillion).Pellets
thataresoft,containexcessiveamountsofloosesawdust,havebeen,orarewet,willresultinreducedperformance.
SAFETy ANd EPA COMPLiANCE
YourKing/AshleystovehasbeensafetytestedandlistedtoASTME1509,(UM)84-HUDbyOMNI-TestLaboratories,
Inc.Portland,Oregon,USA.ItisalsocertiedandtestedtoEPAPhaseIIrequirements.
8/3/2019 5500 Series Copy
5/24
USSC 5
iNSTALLATiON OPTiONS
Read this entire manua efore ou insta and use ourKing/Ashley stove. Faiure to foow instructions
ma resut in propert damage, odi injur, or even death!
(See specic instaation detais for cearances and other instaation requirements)
AFreestanding Unitsupportedbypedestal/legsandplacedonanon-combustibleoorsurfaceincompliancewith
clearancerequirementsforafreestandingstoveinstallation.
AnAcove Unitsupportedbypedestal/legsandplacedonanon-combustibleoorsurfaceincompliancewithclearance
requirementsforanalcoveinstallation.
YourKing/Ashleystovemaybeinstalledtocodeineitheraconventionaormoie home (seeSPECIALMOBILE
HOMEREQUIREMENTS).
ItisrecommendedthatonlyaauthorizedtechnicianinstallyourKing/Ashleystove,preferablyanNFIcertiedspecialist
Installation
iMPrOPEr iNSTALLATiON: Themanufacturerwillnotbeheldresponsiblefordamagecausedbythemalfunc-
tionofastoveduetoimproperventingorinstallation.Call(800)750-2723and/orconsultaprofessionalinstaller
ifyouhaveanyquestions.
FLOOr PrOTECTiON
Thisunitmustbeinstalledonanon-combustibleoorsurface.Ifaoorpadisused,itshouldbeULlistedorequal.
Theoorpadornon-combustiblesurfaceshouldbelargeenoughtoextendaminimumof6-inchesinfront,6-incheson
eachside,and1-inchbehindthestove(seeFIGURE1).
Floorprotectionmustextendunderand2-inchestoeachsideofthechimneyteeforaninteriorverticalinstallation(see
FIGURE2).
YourKing/Ashleystovewillneedaminimum31x38oorprotector.
AFloorProtectorof1inchthickisrecommendedforthisinstallation.
8/3/2019 5500 Series Copy
6/24
6 USSC
Installation
CLEArANCES
YourKing/Ashleystovehasbeentestedandlistedforinstallationinresidential,mobilehome,andalcoveapplications
inaccordancewiththeclearancesgiveninFIGURES3-5andTABLE1.
NOTE: Distance C on the left-hand side of your King/Ashley stove may need to be greater than the mini-
mum required clearance for suitable access to the control panel.
FigurE 3SIDEWALLCLEARANCES
PARALLELINSTALATION
FigurE 4SIDEWALLCLEARANCES
CORNERINSTALATION
FigurE 5ALCOVECLEARANCES
PARALLEL A-Backwalltounit 2.00/50mm
B-Sidewalltoue 13.00/330mm
C-Sidewalltotopedgeofunit 8.00/203mm
CORNER D-Adjacentwalltounit 8.00/203mm
ALCOVE E-Alcovedepth 36.00-914mm
(5500(M)only) F-Alcoveheight 60.00-1520mm
TABLE 1CLEARANCES
ALCOVE INSTALLATION
THIS INSTALLATION IS NOT APPLICABLE
FOR MODEL 5500XL.
8/3/2019 5500 Series Copy
7/24
USSC 7
Installation
vENTiNg rEquirEMENTS
Insta vent at cearances specied the vent manufacturer.
Do not connect the peet vent to a vent serving an other appiance or stove.
Do not insta a ue damper in the exhaust venting sstem of this unit.
Thefollowinginstallationguidelinesmustbefollowedtoensureconformitywithboththesafetylistingofthisstoveandtolocalbuildingcodes.
IMPORTANT! Thisunitisequippedwithanegativedraftsystemthatpullsairthroughtheburnpotand
pushestheexhaustoutofthedwelling.Ifthisunitisconnectedtoauesystemotherthanthewayexplained
inthismanual,itwillnotfunctionproperly.
MAXiMuM vENTiNg diSTANCE
InstallationMUSTincludeatleast3-feetofverticalpipeoutsidethehome.Thiswillcreatesomenaturaldrafttoreducethe
possibilityofsmokeorodorduringapplianceshutdownandkeepexhaustfromcausinganuisanceorhazardbyexposing
peopleorshrubstohightemperatures.Themaximumrecommendverticalventingheightis12-feetfor3-inchtypePL
vent.TotallengthofhorizontalventMUSTNOTexceed4-feet.Thiscouldcausebackpressure.Usenomorethan180
degreesofelbows(two90-degreeelbows,ortwo45-degreeandone90-degreeelbow,etc.)tomaintainadequatedraft.
PELLET vENT TyPE
AULlisted3-inchor4-inchtypePLpelletventexhaustsystemmustbeusedforinstallationandattachedtothepipe
connectorprovidedonthebackofthestove(usea3-inchto4-inchadapterfor4-inchpipe).Connectionatbacko
stovemustbesealedusingHi-TempRTV.Use4-inchventiftheventheightisover12-feetoriftheinstallationisove
2,500feetabovesealevel.
WerecommendtheuseofSimpsonDura-VentorMetal-Fabpipe(ifyouuseotherpipe,consultyourlocalbuilding
codesand/orbuildinginspectors).DonotuseType-BGasVentpipeorgalvanizedpipewiththisunit.Thepelletven
pipeisdesignedtodisassembleforcleaningandshouldbecheckedseveraltimesduringtheburningseason.Pellet
ventpipeisnotfurnishedwiththeunitandmustbepurchasedseparately.
PELLET vENT iNSTALLATiON
Theinstallationmustincludeaclean-outteetoenablecollectionofyashandtopermitperiodiccleaningoftheexhaust
system.90-degreeelbowsaccumulateyashandsoottherebyreducingexhaustowandperformanceofthestove
Eachelboworteereducesdraftpotentialby30%to50%.
Alljointsintheventsystemmustbefastenedbyatleast3screws,andalljointsmustbesealedwithHi-TempRTV
siliconesealanttobeairtight.Theareawheretheventpipepenetratestotheexteriorofthehomemustbesealedwith
siliconeorothermeanstomaintainthevaporbarrierbetweentheexteriorandtheinteriorofthehome.
Ventsurfacescangethotenoughtocauseburnsiftouchedbychildren.Noncombustibleshieldingorguardsmaybe
required.
PELLET vENT TErMiNATiON
Donotterminatetheventinanenclosedorsemi-enclosedarea,suchas;carport,garage,attic,crawlspace,underasundeckorporch,narrowwalkway,oranyotherlocationthatcanbuildupaconcentrationoffumes.
Theterminationmustexhaustabovetheoutsideairinletelevation.
Theterminationmustnotbelocatedwhereitwillbecomepluggedbysnoworothermaterials.
Donotterminatetheventingintoanexistingchimney.
8/3/2019 5500 Series Copy
8/24
8 USSC
Installation
vENT TErMiNATiON CLEArANCES:
A)Minimum4-footclearancebeloworbesideanydoororwindowthatopens.
B)Minimum1-footclearanceaboveanydoororwindowthatopens.
C)Minimum3-footclearancefromanyadjacentbuilding.
D)Minimum7-footclearancefromanygradewhenadjacenttopublicwalkways.
E)Minimum2-footclearanceaboveanygrass,plants,orothercombustiblematerials.
F) Minimum3-footclearancefromanforcedairintakeofanyappliance.
G)Minimum2-footclearancebelowevesoroverhang.
H)Minimum1-footclearancehorizontallyfromcombustiblewall.
I) Mustbeaminimumof36-inchesabovetheroofand24-inchesabovethehighestpointortheroofwithin10-feet.
G
8/3/2019 5500 Series Copy
9/24
USSC 9
Installation
ThrOugh ThE wALL iNSTALLATiON(RECOMMENDEDINSTALLATION)
Toventtheunitthroughthewall,connectthepipeadapter
totheexhaustmotoradapter.Iftheexhaustadapterisat
least18-inchesabovegroundlevel,astraightsectionof
pelletventpipecanbeusedthroughthewall.
YourKing/Ashleydealershouldbeabletoprovideyou
withakitthatwillhandlemostofthisinstallation,whichwill
includeawallthimblethatwillallowtheproperclearance
throughacombustiblewall.Onceoutsidethestructure,a
3-inchclearanceshouldbemaintainedfromtheoutside
wallandacleanoutteeshouldbeplacedonthepipewith
a90-degreeturnawayfromthehouse.Atthispoint,a
3-foot(minimum)sectionofpipeshouldbeaddedwitha
horizontalcap,whichwouldcompletetheinstallation(see
FIGURE7).
A support bracket should be placed justbelow the
terminationcaporoneevery4-feettomakethesystem
morestable.Ifyouliveinanareathathasheavysnowfall,
itisrecommendedthattheinstallationbetallerthan3-feettogetabove thesnowdrift line.This same installation
canbeusedifyourstoveisbelowgroundlevelbysimply
addingtheclean-outsectionandverticalpipeinsideuntil
groundlevelisreached.Withthisinstallationyouhaveto
beawareofthesnowdriftline,deadgrass,andleaves.We
recommenda3-footminimumverticalriseontheinsideor
outsideofthehouse.
Thethroughthewallinstallationistheleastexpensiveandsimplestinstallation.Neverterminatetheendventundera
deck,inanalcove,underawindow,orbetweentwowindows.WerecommendSimpsonDura-Vent orMetal-Fabkits
ThrOugh ThE rOOF/CEiLiNg iNSTALLATiON
Whenventingthestovethroughtheceiling,thepipeisconnectedthesameasthroughthewall,excepttheclean-out
teeisalwaysontheinsideofthehouse,anda3-inchadapterisaddedbeforetheclean-outtee.
Youmustusetheproperceilingsupportangesandroofashing(suppliedbythepipemanufacturer;followthepipe
manufacturersdirections).Itisimportanttonotethatifyourverticalrunofpipeismorethan15-feet,thepelletventpipe
sizeshouldbeincreasedto4-inchesindiameter.
Donotexceedmorethan4-feetofpipeonahorizontalrunanduseasfewelbowsaspossible.Ifanoffsetisrequired
itisbettertoinstall45-degreeelbowsratherthan90-degreeelbows.
FigurE 7TYPICALTHROUGHTHEWALLINSTALLATION
8/3/2019 5500 Series Copy
10/24
10 USSC
Installation
OuTSidE Air SuPPLy (optional)
Dependingonyourlocationandhomeconstruction,outsideairmaybenecessaryforoptimalperformance.
Metalpipe(solidorexible)mustbeusedfortheoutsideairinstallation.PVCpipeisNOTapprovedandshouldNEVER
beused.
Awindshieldovertheterminationoftheoutsideairpipeora90-degreeelboworbendawayfromtheprevailingwinds
MUSTbeusedwhenanoutsideairpipeisinstalledthroughthesideofabuilding.TheoutsideairterminationMUSTbeatleast1-footawayfromtheexhaustsystemtermination.
TheoutsideairpipeonyourKing/Ashleystoveis17/8OD.Theoutsideairconnectingpipemustbeatleast17/8ID.
TheoutsideairconnectionusedMUSTNOTrestricttheamountofairavailabletoyourstove.Theoutsideairconnecting
pipemustbeasshortandfreeofbendsaspossible,anditmusttover,notinside,theoutsideairconnectiontothestove.
NOTE:Dimensionsfromtheoortoyourstovesinlet/exhaustpipesare approximateandmayvary
dependingonyourinstallation.
FigurE 9TYPICALFRESHAIRTERMINATION
FigurE 8EXHAUST/INLETLOCATIONS
SPECiAL MOBiLE hOME rEquirEMENTS
WARNING! - DO NOT INSTAll IN A SlEEPING ROOM
CAUTION! - THE STRUCTURAl INTEGRITy OF THE MObIlE HOME FlOOR, WAll, AND CEIlING/ROOF
MuST BE MAiNTAiNEd.
Inaddition to thepreviouslydetailed installationrequirements,mobile homeinstallationsmustmeet thefollowing
requirements:
Thestovemustbepermanentlyattachedtotheoor.Thestovemustbeelectricallygroundedto thesteelchassisofthemobilehomewith8GAcopperwireusinga
serratedorstarwashertopenetratepaintorprotectivecoatingtoensuregrounding.
Ventmustbe3or4-inchPLVentandmustextendaminimumor36-inchesabovetherooineofthemobilehome
andmustbeinstalledusingaUL/ULClistedceilingrestopandraincap.
Whenmovingyourmobilehome,allexteriorventingmustberemovedwhilethemobilehomeisbeingrelocated.
Afterrelocation,allventingmustbereinstalledandsecurelyfastened.
OutsideAirismandatoryformobilehomeinstallation.Seeyourdealerforpurchasing.
Checkwithyourlocalbuildingofcialsasothercodesmayapply.
8/3/2019 5500 Series Copy
11/24
USSC 11
How your stove works
YourKing/Ashleystoveutilizesainclinedaugerfuelfeedsystemthatisoperatedbyamicroprocessorcontrolleddigita
circuitboard.Thedigitalcircuitboardallowstheinclinedaugerfuelfeedsystemtoruninatimer-based,non-continuous
cycle;thiscyclingallowstheaugertorunforapredeterminedperiodofseconds.Theaugerpushespelletsupachute
locatedatthefront/bottomofthehopperwhichinturnfallsthroughanotherchuteintotheburnpot.Yourstoveisequipped
withanautomaticignitionsystemthatshouldignitethefuelwithin5-10minutesfrompressingtheONbutton.Aspellets
entertheburnpotandignite,outsideairisdrawnacrossthefuelandheatedduringthecombustionprocesswhichisthenpulledthroughtheheatexchangerbytheexhaustmotorordraftfan.Asthestoveheatsup,roomairiscirculated
aroundtheheatexchangerbymeansofaroomairblower,distributingwarmairintotheroom.
Theamountofheatproducedbythestoveisproportionaltotherateofthefuelthatisburned,andthisrateiscontrolled
bytheHEATRANGEsetting.Inordertomaintaincombustionofthefuelatadesiredrate,theairprovidedtotheburn
chamberbytheexhaustordraftfanmustbemaintainprecisely.Toolittleairwillresultinaamethatisnon-energetic
orlazy.Ifthefuelcontinuestoowwithtoolittleairforlongenough,theburnpotwillllwithtoomuchfuelandthere
willsmotherout.Tomuchairwillresultinaamethatisoveractiveoraggressive.Theameinthissituationistypically
veryblueatthebottomandresemblesablowtorch.Ifthissituationcontinues,thefuelintheburnpotwillbeconsumed
andtherewillgoout.
Matchingtheamountofairrequiredforpropercombustiontothefuelrateistheprimaryobjectiveineffectivelyburning
pelletsofvariousbrandsandqualitiesinyourstove.Theairtofuelratiocanbeadjustedtoallowalmostanyfuelquality
toburneffectivelybyfollowingtheproceduresdetailedintheremainderofthismanual.
Becauseaforceddraftpressureisrequiredforthecombustionprocessinsideyourstove,itisextremelyimportanttha
theexhaustsystembeproperlyinstalledandmaintained.And,thatwhenoperatingyourstove,youmakesurethatthe
viewingdoorisproperlysealed.
Understanding your stove
4 Digit Display
Up / Down
Buttons :
Heat Range
Room Fan
Draft FanAuto Mode
Indicator
Auger Delay
Indicator & ButtonOff Indicator
& Button
On Indicator
& Button
FigurE 10DIGITALCONTROLPANEL
8/3/2019 5500 Series Copy
12/24
12 USSC
Control Panel Overview
ON/OFFPressingtheONbuttononthecontrolpanelwillbeginthestart-upsequencefortheheater.Fuelwillbeginto
feedthroughtheaugerfeedsystemafter3minutes.PressingandholdingtheONbuttonwillrotatetheauger
continuouslyuntilbuttonisreleased,whichfeedsadditionalfuel.
PressingtheOFFbuttononthecontrolpanelwillcausetheheatertoenteritsshut-downsequence.Thefuel
feedsystemwillstoppullingfuelfromthehopperand,oncetheregoesoutandtheheatercoolsdown,thefans
willstoprunning.
hEAT rANgE
PressingtheHeatRangearrows,upordown,willadjusttheamountoffuelbeingdeliveredtotheburnpot.
drAFT FAN
Thedraftfan(exhaust)willcomeonassoonastheONbuttonispressed.Thefanwillautomaticallyadjustits
speedinaccordancetotheheatrangesetting.However,thisspeedcanbemanually operatedbypressingtheDraftFanarrowsupordown.DraftFanwhenpressed,thedisplaywillshowDf-A,whichisautomatic.Press
thearrowsagaintoadjustfanspeed.Whentheheaterisinthemanualmode,theoptionalthermostatwillnot
properlycontroltheunit.WhenadjustingtheDraftFansetting,tryonly1settingaboveorbelowtheheatsetting.It
isbettertoleavethestoveintheautomaticmode.
rOOM FAN
Theroomfanwillcomeononcetheunithasreachedoperatingtemperature.BypressingtheRoomFanbuttons,
thedisplaywillshowRf-AwhichisautomaticorRf-1throughRf-9formanualsettings.Inautomode,theroom
fansspeedwillautomaticallybeadjustedinaccordancewiththeheatrangesetting.BypressingtheRoomFan
uparrow,youcanadjustthefanspeedsettinguptoRf-9.Theroomfanmustoperateatalevelgreaterthanor
equaltotheheatrangesetting.
AuX-USEDTORETURNTHESTOVETOTHEFACTORYSETTINGS
Toreturnthestovetoitsoriginalfactorysettings,pressandholdtheAUXUPandAUXDOWNbuttonssimultaneously
for3seconds.
AugEr dELAy
TheAugerDelaybuttoncanbeusedtopauserotationoftheAugerforapprox.1minute.Thiscanbecancelledby
pressingtheONbutton.TheAugerDelayisnormallyusedonlyduringthestartupcycletoslowthefueldelivery
downduringtheinitialignition.
MOdE
TheModebuttonisusedtoswitchbetweenmanualandautomaticmode.Wheninautomode,thefansandauger
willoperateatpresetintervalsunlesschangedmanuallyusingthebuttonsmentionedabove.Wheninmanualmode,
thedraftfan(exhaust)willoperateatfullspeed(100%).
Duringnormaloperation,theunitisconstantlymonitoredforproblems.Intheeventofanerrorcondition,theunitwillstopandanerrorwillbedisplayed.Seethelistoferrorcodesfoundattheendofthismanual.
TurningtheheaterON/OFF,aswellasadjustmentsforthefuelfeedrateandroomfanspeedareperformedbypressing
theappropriatebutton(s)onthecontrolpanelwhichislocatedonthelowerleft-handsideofyourheater.
Thisunitcanbechangedbetweenanautomaticoperationoramanualoperation.Thecontrollercomesdefaultinthe
automaticmode.
8/3/2019 5500 Series Copy
13/24
USSC 13
uNiT PrEPArATiON
Aftercarefullyunpackingandreadingtheinstructionsforinstallingyourstove,youwillneedtoperformthefollowingsteps
Attachtheincludedspringhandletothedoorhandlebyscrewingitoninarespectivelocation.
Attachtheelectricalcordtothebackofthestoverst;thenplugitintoa110-voltoutlet(anoutletsurgeprotectoris
highlyrecommended).
PErFrOMiNg AN iNTiAL TEST
Thistestisusedatthefactorywherethestovesareassembledtotestthefunctionalityofthecontrolandthestove
beforetheunitisshipped.Toperformthistest,pressandholdtheOFFandAUGERDELAYbuttonssimultaneouslyfor
3seconds.Toadvancethroughthetest,pressanykeyunlessotherwisenotedintheteststep.
ExhaustFanOutputTestThedisplaywillshowdrft.Theexhaustfanisturnedonfullthenreducedtoaleveljust
abovethetypicalminimumpressureswitchsetting.TheONLEDindicateswhetherthepressuresensorisdetected
Ifthepressureswitchisnotdetected,thefanrampstofullonfortwosecondsthenreturnstothepreviouslyestablished
levelifthepressureswitchcloses.IftheDraftFanFuseisnotblownandthefusedetectioncircuitisfunctioning
theDraftFanLEDwillbelitandtheotherthreetoprowLEDswillbeoff.
RoomFanOutputTest-Thedisplaywillshowrfan.Theroomfanisturnedonfull.IftheRoomFanFuseisno
blownandthefusedetectioncircuitisfunctioning,theRoomFanLEDwillbelitandtheotherthreetoprowLEDs
willbeoff.
IgnitorOutputTest-Thedisplaywillshowignt.Theignitormotoristurnedonfull.IftheIgnitor(AUX)Fuseisnot
blownandthefusedetectioncircuitisfunctioning,theAuxLEDwillbelitandtheotherthreetoprowLEDswillbeoff
AugerOutputTest-Thedisplaywillshowaugr.Theaugermotoristurnedonfull.IftheAugerFuseisnotblown
andthefusedetectioncircuitisfunctioning,theHeatRangeLEDwillbelitandtheotherthreetoprowLEDswillbeoff.
HopperSwitchTestThedisplaywillshowhppr.TheONLEDislit.Ifthehopperswitchisopen(lidisopen)
theHEATRANGELEDwillturnon.Ifthelidisclosed,theHEATRANGELEDwillbeoff.
ThermostatInputTestThedisplaywillshowstat.If thethermostatinputisclosed,theONLEDwillturnon
otherwiseitwillbeoff.
FluegasThermistorTestThedisplaywillshowtheuegastemperatureindegreesF.
ACFrequencyTest-DisplaysthemeasuredACFrequencyinhertzfollowedbytheletterH.WatchdogResetThewatchdogtimeris testedtoensurethattheboardcanbe reset.ThemessageBYEis
displayeduntilthewatchdogresetstheboard.
Operation
1.)
2.)
3.)
4.)
5.)
6.)
7.)
8.)9.)
PErFOrMiNg A dry ruN
Performadryrunonyourstovepriortomakingtheexhaust/inletconnectionsandstartingyourstoveforthersttime.
CheckthatthereisNOfuelorANYforeignmaterialinthehopperorburn-pot.
Checkthattheviewingdoorandhopperlidissecurelyclosed.
PresstheONbuttononthecontrolpanel.VerifythattheONLEDislit(blinking)andthedisplayshowsHR-1.Also
theLEDabovetheHEATRANGEandtheAUTOMODEindicatorshouldbelit.IfanyotherLEDsarelitorashingconsulttheDisplayIndicatorsinthismanual.
Youshouldheartheexhaust(draft)fanrunningimmediatelyandtheaugershouldbeginturningcontinuouslyfor1
minute.
Theautofuelignitor(locatedinsidethebackwalloftheburnpot)shouldbegintoglowred/orangeafter3minutes.
TheRoomFanwillnotoperateatthistimesincetheunitmustreachafactorypresettemperature.
DONOTopentheviewingdoor,theauto-start igniterwillgetveryhotduringthistest.Thestovewillautomatically
shutdownafterapproximately23minutes.
1.)
2.)
3.)
4.)
5.)
6.)
8/3/2019 5500 Series Copy
14/24
14 USSC
ShuT dOwN PrOCEdurE
PresstheOFF buttononthecontrolpadtoputthestoveinshutdownmode.Atthistime,theredlightabovethepad
willilluminate.Oncethisisdone,theaugerwillstopfeedingpellets,butthedistributionblowerandexhaustblowerwill
continuetooperate.Whentheinternaltemperatureoftheunitdropsbelowthefactorypresettemperature,thedistribution
blowerandexhaustblowerwillceasetooperate.Theredlightwillthenshutoffandtheunitwillbecompletelyshutdown.
Thehottertheunitisduringitsoperation,thelongeritwilltakeforthestovetocompletetheshutdowncycle.Ifthe
stovestaysonformorethan2hoursafterpressingthe OFF buttonandyouaresurethatthereisout,thestovecan
beunpluggedfromtheoutlet.Afterapproximately10seconds,theunitcanbere-connectedtothepowersourceand
thecontrolboardwillbereset.
Operation
STArT-uP PrOCEdurE
Never use gasoine, gasoine-tpe antern fue, kerosene, charcoa ighter uid, or simiar iquids to start or
freshen up a re in this stove. Keep a such iquids we awa from the stove whie it is in use.
Verifythatthehopperiscleanandfreeofforeignmatter.
Verifythatalloftherequiredexhaust/inletconnectionshavebeenmadeinaccordancewiththismanualandthat
thestoveispluggedintoanoutlet(anoutletsurgeprotectorishighlyrecommended).
Fillthehopperwithwoodpellets;donotallowanypartofthebagoranyotherforeignmaterialintothehopper,as
thismayjamtheauger.
Ensurethatallpelletmatterisclearedfromthehopperseatingsurface.
Closethehopperlid.The unit WIll NOT feed fue with the hopper id open.
Makesurethattheviewingdoorissecurelyclosed(thesafetypressureswitchwillnotallowthestovetofeedfuel
ifthereisnodraftpressureinsidethestove).
PresstheON buttononthecontrolpadandsetthehEAT SETTiNg toyourdesiredsetting.
Thestovewillbegintofeedfuelandtheauto-start igniterwillignitethefuelinapproximately5minutes.
Onceaconsistentamehasbeenestablished,youcanadjusttheHEATRANGEandBLOWERSPEEDonthecon -trolpadtoyourdesiredsettings.(Note:Thedistributionblowerwillnotfunctionuntiltheheatexchangerinthestove
reachesthefactorypresettemperature).
1.)
2.)
3.)
4.)
5.)
6.)
7.)
8.)
First Fire: AdjustthehEAT rANgE andBLOwEr SPEEd toa3 settingandallowthestove
tooperateinthismannerforapproximatelythree(3)hours(ormoreifnecessary),allowingthestoveto
cureoutasthepaintandoilsfromthemanufacturingprocessburnoff.Werecommendthatyouopen
doorsandwindowsinyourhomeduringthisprocess.Adjustsettingtodesiredsetting.
WARNING: Never shut down this unit unpugging it from the power source.
8/3/2019 5500 Series Copy
15/24
USSC 15
Maintenance
Operation
dAiLy OPErATiON
The hopper and stove top wi e hot during operation; therefore, ou shoud awas use some tpe of hand
protection when refueing our stove.
Never pace our hand near the auger whie the stove is in operation.
Thisunitshouldbelledwhenthehopperleveldropsbelow3-inches.
Intheeventofapower outage,thestoveWILLNOTfunction.Itisveryimportantthatunitbeventedproperly(with
outsideair),asthenaturaldraftisneededtoclearthesmokefromthestoveduringapoweroutage.IftheunitwasONwhenthepoweroutageoccurred,oneofthefollowingwilltakeplace:
Ifthestoveisstillwarm,itwillresumefeedingfuelandcontinuetooperatenormally.Iftherehasgoneout,you
willhavetopresstheOFF buttonandthentheON buttonagaintobeginanewstart-upsequence.
Ifthestovehascooled-off,itwillresettoits OFF condition.Atthispoint,youmaypressthe ON buttonandthe
unitwillbeginanewstart-upsequence.
NOTE:Theunitwillalsoshutdownintheeventofanexhaustblowerfailure;ifthisisthecase,theunitwillnotre-star
andyoumustcontactCustomerServiceat(800)750-2723.
SAFETy ANd CONvENiENCE FEATurESYourKing/Ashley incorporatesasafet pressure switch thathelpsensurethateverythingisinproperworkingorde
beforefeedingfueltotheburnpot.Becausethestoveworksusinganinduceddraftpressure,thestovewillnotcontinue
tooperateiftheviewingdoorisleftopen;oriftheexhaustblowerfailsortheexhaustsystemisblocked.
Thetemperature imit controwillpreventyourstovefromoperatingatabnormallyhightemperatures.Shouldthestove
temperaturebegintoapproachthefactorypre-setlimit,thetemperaturelimitcontrolwillautomaticallyslowdownthe
augerfeedrateuntilthetemperaturereturnstoanormalcondition.Eventhoughtheheaterwilloperateonsetting5
(HI),werecommendtooperateyourheateronthissettingforonlyashortperiodoftime.(1houretc.)
YourKing/Ashleystovealsoincludesanauto-start igniterasastandardfeature.Theuseofotherrestartermaterials
(woodchips,startergel,etc.)isnotnecessary.Bysimplypressingthe ONbuttononthedigitalcontrolpanel,your
stovewillbegintofeedfuelandautomaticallystartwithin5minutes.
1.)
2.)
Faiure to cean and maintain this unit as indicated can resut in poor performance and safet hazards.
Unpug our stoves eectrica cord prior to removing the ack pane or opening the exhaust sstem for an
inspection, ceaning, or maintenance work.
Never perform an inspections, ceaning, or maintenance on a hot stove.
Do not operate stove with roken gass , eakage of ue gas ma resut.
EXhAuST SySTEM
Thebyproductsofcombustioncontainsmallparticlesofyash.Flyashwillcollectintheexhaustventingsystemand
restricttheowofuegases.Incompletecombustion,suchasduringstartup,shutdown,orincorrectoperationofthe
stovewillleadtosootformationwhichwillcollectintheexhaustsystem.Therefore,itisimportantthattheexhaust
systembeinspected and ceaned at east month duringtheburningseason.
Checkthecleanoutteesperiodicallytodeterminetherequiredcleaningschedule.3or4-inchchimneybrushesare
availableforchimneycleaning.Iftheexhaustsystemoroutsideairpipeshavescreensonthem,frequentlycleanthe
screen.Apluggedscreenwillshutoffcombustionairandcausearetodieorburnpoorly.
8/3/2019 5500 Series Copy
16/24
16 USSC
iNTEriOr ChAMBErS
Periodicallyremoveandcleantheburnpotandtheareainsidetheburnpothousing.Inparticularitisadvisabletoclean
outtheholesintheburnpottoremoveanybuildupthatmaypreventairfrommovingthroughtheburnpotfreely.Remove
thetwo(2)platesoneachsideoftheburnpothousingandcleanoutthatrearchamber.
Ifavacuumisusedtocleanyourstove,wesuggestusingavacuumdesignedforashremoval.Someregularvacuum
cleaner(i.e.shopvacs)mayleakashintotheroom.
ASh diSPOSAL
Ashesshouldbeplacedinametalcontainerwithatightttinglid.Theclosedcontainerofashesshouldbeplacedon
anoncombustibleoororontheground,wellawayfromallcombustiblematerials,pendingnaldisposal.Iftheashes
aredisposedofbyburialinsoilorotherwiselocallydispersed,theyshouldberetainedintheclosedcontaineruntilall
cindershavebeenthoroughlycooled.
CHECK AND ClEAN THE HOPPER
Checkthehopperperiodicallytodetermineifthereisanysawdustorpelletsthatarestickingtothehoppersurface.
Cleanasneeded.
DOOR AND GlASS GASKETS
Inspectthemaindoorandglasswindowgasketsperiodically.Themaindoormayneedtoberemovedtohavefrayed,
broken,orcompactedgasketsreplacedbyyourAuthorizedKing/AshleyDealer.Theglassgaskethasagapatthe
bottomfortheairwash.
BLOwEr MOTOrS
Cleantheairholesonthemotorsofboththeexhaustanddistributionblowersannually.Removetheexhaustblower
fromtheexhaustductandcleanouttheinternalfanbladesaspartofyourfallstart-up.
PAiNTEd SurFACES
Paintedsurfacesmaybewipeddownwithadampcloth.Ifscratchesappear,oryouwishtorenewyourpaint,contact
yourAuthorizedKing/AshleyDealertoobtainacanofsuitablehigh-temperaturepaint.
gLASS
Werecommendusingahighqualityglasscleaner.Shouldabuildupofcreosoteorcarbonaccumulate,youmaywish
touse000steelwoolandwatertocleantheglass.Intheeventyouneedtoreplacetheglass,onlyhightemperature
ceramicglassofthecorrectsizeandthicknessmaybeused.ContactyourAuthorizedKing/AshleyDealertoobtainthisglass.
FALL STArT uP
Priortostartingtherstreoftheheatingseason,checktheoutsideareaaroundtheexhaustandairintakesystems
forobstructions.Cleanandremoveanyyashfromtheexhaustventingsystem.Cleananyscreensontheexhaust
systemandontheoutsideairintakepipe.Turnallofthecontrolsonandmakesurethattheyareworkingproperly.This
isalsoagoodtimetogivetheentirestoveagoodcleaningthroughout.
SPriNg ShuTdOwN
Afterthelastburninthespring,removeanyremainingpelletsfromthehopperandtheaugerfeedsystem.Scoopout
thepelletsandthenruntheaugeruntilthehopperisemptyandpelletsstopowing(thiscanbedonebypressingthe
ON buttonwiththeviewingdooropen).Vacuumoutthehopper.Thoroughlycleantheburnpot,andrebox.Itmay
bedesirabletospraytheinsideofthecleanedhopperwithanaerosolsiliconesprayifyourstoveisinahighhumidity
area.Theexhaustsystemshouldbethoroughlycleaned.
yEArLy SErviCiNg
AyearlyservicingandcleaningbyyourAuthorizedKing/AsheDealerisrecommended.Afeemaybechargedfor
thisservice.
Maintenance
8/3/2019 5500 Series Copy
17/24
USSC 17
Trouble Shooting
Disconnect the power cord efore performing an maintenance! NOTE: Turning the ON/OFF Switch to OFF
does not disconnect a power to the eectrica components of the stove.
Never tr to repair or repace an part of the stove uness instructions for doing so are given in this manua
A other work shoud e done a trained technician.
PrOBLEM CAuSE:Torichair/fuelmixture
Orange, lazy flame_excessive fuel
build-upintheburnpot
Cleanouttheburnpotandburnpothousing
Makesurethattheviewingdoorisclosedandsealedproperly.Ifnot,
adjustdoorcatchand/orreplacedoorgaskets.
Checkthatalloutsideconnectionsareclearofanyobstructions.
Checktheexhaustsystem;cleanasneeded.
PrOBLEM CAuSE:Burnpotburnsoutoffuel
Firegoesoutorstoveshutsdown. Hopperisempty,rellthehopper.
Lossofdraftpressure.Makesurethattheviewingdoorisclosedand
sealedproperly. Ifnot, adjustdoorcatchand/or replacedoorgaskets.
Checkthatalloutsideconnectionsareclearofanyobstructions.Check
theexhaustsystem;cleanasneeded.
Checkthatthepressureswitchconnectiontothereboxisfreeofashor
clearofobstructions.
Augersystemisjammedorthereisabridgingofthefuelinthehopper,
preventingfuelfromowingintotheaugerfeedsystem.
PrOBLEM CAuSE:Auto-StartIgniterfailstoignitethefuelintheburnpot.
Stovedoesnotstartarewhenthe
ONbuttonispushed
TurnthestoveOFF.Cleartheunburntfuelfromtheburnpotandtry
again.
Checkthepelletquality.Replaceifmoist,wet,ordirty. Lossofdraftpressure.Makesurethattheviewingdoorisclosedand
sealedproperly. Ifnot, adjustdoorcatchand/or replacedoorgaskets.
Checkthatalloutsideconnectionsareclearofanyobstructions.Check
theexhaustsystem;cleanasneeded.
Check that theauto-startigniterisnotblockedwithashorsoot. (The
igniterislocatedbehindtheburnpotonthebackwalloftherebox.)
Checkthatthepressureswitchconnectiontothereboxisfreeofashor
clearofobstructions.
Theauto-startignitergetsredhotduringstart-up.Ifyoucannotvisibly
seetheigniterglowingduringstart-up,thentheignitermayneedtobe
replacedorthereisaproblemwiththeelectricalcontrolsystem.
8/3/2019 5500 Series Copy
18/24
18 USSC
Error
Code
E1
E2
E3
E4
E5
E6
E7
E8
Error
Descrption
Thehighlimittemperaturesensor
hastripped.
Stoveranoutoffuelduringnormal
operation.
Thestovewasunabletoreachthe
RoomFanOntemperaturewithinthe
startuptime.
Thepowerfailedwhilethestovewas
hot,andwhenpowerwasrestored,
therewasout.
TheAugeroutputfusehasblown.
TheIgnitoroutputfusehasblown.
TheDraftFan (ExhaustFan)output
fusehasblown.
TheRoomFanoutputfusehasblown.
Possible
Causes
Inadequateventilation.
Roomfanfailure.
ExhaustBlockage.
ElectricalOpenintheovertemperatureswitchorwiring.
HopperEmpty.
Augeroutputfailureorjam.
Flameoffuelqualitycausedretoburntooslowlyorgoout.
ElectricalOpeninlowtemperatureswitchorwiring.
FlameorFuelqualitycausedtheretoburntooslowlyorgo
out.
AugeroutputfailureorjamHopperemptyonstartup.
ElectricalOpeninlowtemperatureswitchorwiring.
Powerloss
Augermotorjammedorbad.
Ignitorshortedoutorbad.
DraftFanmotorjammedorbad.
Roomfanmotorjammedorbad.
Dispa Indicators
Severalsituationsoreventsareindicatedinnormaloperationbyblinkingdisplayindicatorsorsegmentsinthedisplay:
Fashing On Indicator:ThismeansthatthestoveisintheStartUpstatewaitingforeithera3minutetimeouttobegin
burningorforthestovetoreachthewarmtemperaturewhichevercomesrst.
Fashing Off Indicator:ThisindicatesthatthestoveisintheShutdownstatewaitingfortheOFFbutton,orfora15
minuteperiodafterthestovewasturnedoff,orforthestovetocooldown,orforthedoortobeclosed.
Fashing dash in Heat Range Dispa:Thisindicatesthatthestoveisinthenormalrunmodeandisrampingfrom
thecurrentheatrangesettingtothetargetheatrangesetting.Oncetherampiscomplete,thedashwillstopashing.
Forrampingfromheatrange1to5,thedefaulttimeis12minutes(witha90secondramptime).
Fashing Automatic Mode Indicator:Thisindicatesthatthestoveisinnormaloperationandisrunningintheautomatic
mode.However,eithertheDraftFanorAuxiliarysettingismanuallycongured.
Fashing Draft Fan Setting Indicator:Thisindicatesthatthestoveisinnormaloperationandthatthevacuumsensor
detectsalossofpressureeitherbecausethedoorisopenorbecausethereisanegativepressureintheroomwith
respecttotheexhaust.
Fashing Aux Indicator: Thisindicatesthattheignitorisonduringthelightingstage.
Quick (changes twice per second) Fashing Heat Range Setting Indicator:Thisindicatesthatthestoveisinnormaloperationandthatanovertemperatureconditionexistscausingthefueltostop.
Sow (changes once per second) Fashing Heat Range Setting Indicator: Thisindicatesthatthestoveisinacut
backconditioninanattempttopreventanovertemperatureshutdown.
Factor Defauts
Toreturnthecontroltoitsoriginalfactorydefaultsettings,pressandholdtheAUXUPandAUXDOWNbuttonstogether
forthreeseconds.
Error Codes and Display Indicators
8/3/2019 5500 Series Copy
19/24
USSC 19
13
5
11
10
1
10
12
10
6
12
7
8
2
4
3
9
9
9
Parts Diagram/List models 5500, 5500M & 5500XL
11
3
2
1
5
6
4
7
98
10
12
Item Part No. Tite Qt.1 25490 DoorWeldment 1
2 891166 CeramicGlass 1
3 891188 GlassRetainer,Top 1
4 891186 GlassRetainer,Bottom 1
5 25517 Handle,Door 1
6 891168 Latch,Door 1
7 88082 3/4RopeGasket 4.3ft
PARTSLIST
Item Part No. Tite Qt.8 88087 GlassGasket 3.75ft
9 83297 8-32HexNut 3
10 83547 Washer 3
11 83903 Spring 1
12 83546 5/16x18HexJambNut 2
13 891167 SpringHandle 1
Item Part No. Tite Qt.
1 25507 FeedDoor 1
2 25492 Handle,Door 1
3 83506 3/8x11/4RollPin 1
4 891067 DoorGlassw/AshleyLogo 1
5 88066 5/8RopeGasket 4.5ft
6 88087 GlassGasket(1x13/16) 3.5ft
7 25520 BottomGlassRetainer 1
8 25521 TopGlassRetainer 1
PARTSLISTItem Part No. Tite Qt.
9 83278 Washer 4
10 83202 MachineScrew 4
11 89574 SpringHandle 1
12 25393 Retainer,Glass(AlternateFor7&8) 1
N/S 25080MB DoorLatch 1
N/S 83508 5/16-18x1-3/4Bolt 1
N/S 83338 5/16-18Lock-Nut 1
N/S-NotShown
Mode 5500
Mode 5500M/5500Xl
8/3/2019 5500 Series Copy
20/24
20 USSC
Parts Diagram model 5500, 5500M and 5500XLNote: All repair parts (other than Cabinet Sides, Hopper Assy., and Door Assy.) are same for models 5500, 5500M and 5500XL.
8/3/2019 5500 Series Copy
21/24
USSC 21
Parts List model 5500/5500M/5500XL
Item Part No. Tite Qt.
1 86624 BurnpotAssembly 1
2 86625 HousingAssy,Burnpot 1
3 86628 Weldment,ExhaustDuct 1
4 86633 Weldment,IgniterTube 1
5 80481 IgniterCartridge 1
6 25506 Weldment,DoorHinge 1
7 69512 DoorAssembly 1
8 69518 HopperAssembly(5500) 1
- 69522 HopperAssembly(5500XL) 1
9 891164 WeldmentAugerHousing 1
10 69513 Assy.,BushingRetainerBottom 1
10.1 891190 Plate,BottomBushing 1
10.2 891132 Bushing 1
10.3 83534 Retaining Ring 1
11 69514 Assy.,BushingRetainerTop 1
11.1 891189 Plate,TopBushing 1
11.2 891132 Bushing 111.3 83534 Retaining Ring 1
12 891161 Weld.,Bot.PlateRetainer 1
13 83543 6-32x3/8MachineScrew 2
14 83356 10-32HexNut 4
15 83299 6-32HexNut 2
16 891195 Bracket,DriveMotor 1
17 25498 Weldment,TopLid 1
18 25511 Weld,LeftSideCabinet(5500) 1
- 25515 Weld,LeftSideCabinet(5500XL) 1
19 80558 CircuitBoardAssembly 1
20 80480 Thermistor 1
21 88117 Gasket,ExhaustDuct 122 88100 Gasket,ExhaustBlower 1
PARTSLIST
Item Part No. Tite Qt.
23 80473 Blower,Exhaust 1
24 88118 Gasket,IgniterFlange 1
25 891169 Hose,Heater 1.5in
26 891141 Auger 1
27 80488 DriveMotor 1
28 83529 Hairpin 1
29 891180 Cover,Auger 1
30 83297 8-32HexNut 4
31 891187 Bracket,PressureSwitch/PCB 1
32 80549 PressureSwitch 1
33 89586 Nipple 1
34 891148 Handle,Plastic 1
35 891121 SiliconeTube 3in.
36 25512 Side,RightCabinet(5500) 1
- 25516 Side,RightCabinet(5500XL) 1
37 25510 Panel,Access 1
38 80472 Blower,Distribution 139 88106 Gasket,DistributionBlower 1
40 25513 Cleanout,Ash 2
41 80491 Microswitch 1
42 88119 Insulation,Blanket 2
43 80462 Receptacle,3Prong 1
44 80461 PowerSupplyCord 1
45 83516 #4-40MachineScrew 2
46 83542 #4-40NylonLockNut 2
47 89390A RubberGrommet 1
N/S 80548 WiringHarness 1
8/3/2019 5500 Series Copy
22/24
22 USSC
Wiring Diagram
GRAY
BLACK
8/3/2019 5500 Series Copy
23/24
USSC 23
Notes
8/3/2019 5500 Series Copy
24/24
This manual will help you obTain efficienT, dependable ser-
vice from your KinG or ashley, and enable you To order repairparTs correcTly.
Keep This manual in a safe place for fuTure reference.
when wriTinG, always Give The full model number which is on
The nameplaTe aTTached To The heaTer.
when orderinG repair parTs, always Give The followinG infor-maTion as shown in This lisT:
1. The parT number
2. The parT descripTion
3. The model number: 5500 5500m 5500Xl
4. The serial number:____________________