TUV Rheinland (Guangdong) Ltd. No.199 Kezhu Road, Guangzhou Science City, Guangzhou 510663, Guangdong Province P.R. China
Produkte Products
Prüfbericht-Nr.: Test Report No.: 16078925 001 Auftrags-Nr.:
Order No.: 174055546 Seite 1 von 31
Page 1 of 31
Kunden-Referenz-Nr.: Client Reference No.: 649327 Auftragsdatum:
Order date.: 12 Sep 2016
Auftraggeber: Client:
Dongguan Daxian Light Technology Co.,Ltd. Floor 2, No.2, Liyuan Road Xuzhen, Zhangmutou Town Dongguan City, Guangdong 523620 P.R. China
Prüfgegenstand: Test item:
LED Strip Light
Bezeichnung / Typ-Nr.: Identification / Type No.: Refer to section 3
Auftrags-Inhalt: Order content:
TUV Rheinland – EMC service
Prüfgrundlage: Test specification:
EN 55015:2013 EN 55015:2013+A1 EN 61547:2009
Wareneingangsdatum: Date of receipt:
12 Sep 2016
Prüfmuster-Nr.: Test sample No.: 174055546-001
Prüfzeitraum: Testing period:
Refer to test report.
Ort der Prüfung: Place of testing:
Refer to section 2.1
Prüflaboratorium: Testing laboratory:
TÜV Rheinland (Guangdong) Ltd.
Prüfergebnis*: Test result*: Pass
geprüft von / tested by:
21 Nov 2016 Storm Shu/Assistant Project Manager
kontrolliert von / reviewed by:
21 Nov 2016 Jeffery Xie/TC
Datum Date
Name/Stellung Name/Position
Unterschrift Signature
Datum Date
Name/Stellung Name/Position
Unterschrift Signature
Sonstiges / Other:
Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery:
Prüfmuster vollständig und unbeschädigt Test item complete and undamaged
* Legende: 1 = sehr gut 2 = gut 3 = befriedigend 4 = ausreichend 5 = mangelhalt P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet
Legend: 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor P(ass) = passed a.m. test specifications(s) F(ail) = failed a.m. test specifications(s) N/A = not applicable N/T = not tested
Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens.
This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark.
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 2 von 31 Page 2 of 31
TEST SUMMARY
5.1.1 HARMONICS CURRENT EMISSION ON AC MAINS RESULT: N/A
5.1.2 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER RESULT: N/A
5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE RESULT: Pass
5.1.4 RADIATED ELECTROMAGNETIC DISTURBANCES RESULT: Pass
5.2.1 RADIATED DISTURBANCE RESULT: Pass
6.2.1 POWER-FREQUENCY MAGNETIC FIELDS RESULT: N/A
6.2.2 RADIO-FREQUENCY COMMON MODE / CONDUCTED SUSCEPTIBILITY (CS) RESULT: Pass
6.2.3 RADIO-FREQUENCY ELECTROMAGNETIC FIELDS (RS) RESULT: Pass
6.3.1 ELECTRICAL FAST TRANSIENTS (EFT) RESULT: Pass
6.3.2 SURGE RESULT: N/A
6.3.3 ELECTROSTATIC DISCHARGES (ESD) RESULT: Pass
6.4.1 VOLTAGE DIPS AND INTERRUPTIONS RESULT: N/A
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 3 von 31 Page 3 of 31
Contents
1. GENERAL REMARKS ........................................................................................................... 5
1.1 COMPLEMENTARY MATERIALS ........................................................................................... 5
2. TEST SITES .......................................................................................................................... 5
2.1 TEST FACILITIES .................................................................................................................. 5
2.2 LIST OF TEST AND MEASUREMENT INSTRUMENTS ............................................................. 6
3. GENERAL PRODUCT INFORMATION .................................................................................... 9
3.1 PRODUCT FUNCTION AND INTENDED USE .......................................................................... 9
3.2 RATINGS AND SYSTEM DETAILS ......................................................................................... 9
3.3 INDEPENDENT OPERATION MODES................................................................................... 10
3.4 NOISE GENERATING AND NOISE SUPPRESSING PARTS .................................................. 10
3.5 SUBMITTED DOCUMENTS .................................................................................................. 10
4. TEST SET-UP AND OPERATION MODES ............................................................................ 11
4.1 PRINCIPLE OF CONFIGURATION SELECTION .................................................................... 11
4.2 PHYSICAL CONFIGURATION FOR TESTING........................................................................ 11
4.3 TEST OPERATION AND TEST SOFTWARE ......................................................................... 11
4.4 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ...................................................... 11
4.5 COUNTERMEASURES TO ACHIEVE EMC COMPLIANCE .................................................... 11
5. TEST RESULTS E M I S S I O N ...................................................................................... 12
5.1 EMISSION IN THE FREQUENCY RANGE UP TO 30 MHZ ..................................................... 12 5.1.1 Harmonics Current Emission on AC Mains ......................................................................................... 12 5.1.2 Voltage Changes, Voltage Fluctuations and Flicker .......................................................................... 12 5.1.3 Terminal Continuous Disturbance Voltage .......................................................................................... 13 5.1.4 Radiated Electromagnetic Disturbances .............................................................................................. 15
5.2 EMISSION IN THE FREQUENCY RANGE ABOVE 30 MHZ ................................................... 17 5.2.1 Radiated Disturbance .............................................................................................................................. 17
6 . TEST RESULTS I M M U N I T Y ..................................................................................... 19
6.1 CLASSIFICATION OF APPARATUS ..................................................................................... 19
6.2 CONTINUOUS DISTURBANCES .......................................................................................... 20 6.2.1 Power-frequency Magnetic Fields ......................................................................................................... 20 6.2.2 Radio-frequency Common Mode / Conducted Susceptibility (CS) ................................................. 21 6.2.3 Radio-frequency Electromagnetic Fields (RS) .................................................................................... 23
6.3 TRANSIENT DISTURBANCES .............................................................................................. 25 6.3.1 Electrical Fast Transients (EFT) ............................................................................................................ 25 6.3.2 Surge .......................................................................................................................................................... 27 6.3.3 Electrostatic Discharges (ESD).............................................................................................................. 28
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 4 von 31 Page 4 of 31
6.4 POWER SUPPLY ALTERATIONS ........................................................................................ 30
6.4.1 Voltage Dips and Interruptions ............................................................................................................... 30
7. LIST OF TABLES ................................................................................................................ 31
8. LIST OF PHOTOGRAPHS .................................................................................................... 31
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 5 von 31 Page 5 of 31
1. General Remarks
When applying the basic standards in this test report, please refer to the applied generic or product family standards for edition information: For dated basic standards, only the edition cited applies. For undated basic standards, the latest edition (including any amendments) applies.
1.1 Complementary Materials
All attachments are integral parts of this test report. This applies especially to the following appendix: Appendix 1: Test result.
2. Test Sites
2.1 Test Facilities
STC (DONGGUAN) COMPANY LTD No.168, Fuminnan Road, Dalang Town Dongguan, Guangdong 523770 P.R.China The test at this test site has been conducted under the supervision of a TÜV Rheinland engineer.
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 6 von 31 Page 6 of 31
2.2 List of Test and Measurement Instruments
Table 1: List of Test and Measurement Equipment
Test Equipment Manufacturer Model Serial No. Cal. Due Date
STC (DONGGUAN) COMPANY LTD Harmonics & Flicker
AC power source SCHAFFNER NSG1007 54964 2017.03.29
Harmonic & flicker meter
SCHAFFNER CCN1000 72104 2017.03.29
Harmonics/ Flicker Test software
TESEQ Win2100V3 V3.2.0.35 N/A
Disturbance Voltage
EMI Test Receiver ROHDE & SCHWARZ
ESHS 10 8468601002 2017.03.29
ZWEILEITER-V-NETZNACHBILDUNG
TWO-LINE V-NETWORK
ROHDE & SCHWARZ
ESH3-Z5 100102
2017.03.29
Passive Voltage Probe
ROHDE & SCHWARZ
ESH2-Z3 100020 2017.03.29
EMI Test Receiver ROHDE & SCHWARZ
ESCS 30 100314 2017.03.29
EMI Test Receiver ROHDE & SCHWARZ
ESIB26 100388 2017.03.29
TWO-LINE V-NETWORK
ROHDE & SCHWARZ
ENV216 100261 2017.03.29
4-WIRE ISN ROHDE & SCHWARZ
ENY41 100205 2018.03.24
Intelligent Frequency Ainuo lnstrument
Co., Ltd AN97005SS 79707455
N/A
Shielding Room #1 ETS.LINDGREN RFD-100 3802 N/A
CE Test software ROHDE & SCHWARZ
ESIB-K1 V1.20 N/A
Radiated Emission(Magnetic Field ‘Van Veen’)
EMI Test Receiver ROHDE & SCHWARZ
ESCS 30 100314 2017.03.29
Magnetic Loop Antenna
SHWARZBECK HXYZ9170 N/A 2017.03.24
Shielding Room #2 ETS.LINDGREN RFD-100 3804 N/A
H-Field Test software ROHDE & SCHWARZ
ESxS-K1 V2.10 N/A
Radiated Emission
Signal Generator MARCONI
INSTRUMENTS 2030 112191/012 2017.03.29
EMI Test Receiver ROHDE & SCHWARZ
ESCS 30 100314 2017.03.29
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 7 von 31 Page 7 of 31
Test Equipment Manufacturer Model Serial No. Cal. Due Date
EMI Test Receiver ROHDE & SCHWARZ
ESCI 100441 2017.03.29
EMI Test Receiver ROHDE & SCHWARZ
ESIB26 100388 2017.03.29
Biconilog Antenna Antenna Research
Associocles Inc. LPB-2513 1069 2017.06.27
Biconilog Antenna ETS.LINDGREN 3142C 00060445 2017.11.15
Biconilog Antenna ETS.LINDGREN 3142C 00060439 2016.11.29
Double-Ridged Waveguide
ETS.LINDGREN 3117 00075933 2017.11.15
MULTI-DVICE CONTROLLER
ETS.LINDGREN 2090 00060107 N/A
Monitor ViewSonic VA9036 Q8X06420187
6 N/A
FACT-3 EMC Chamber
ETS.LINDGREN FACT-3 3803 N/A
Power meter ROHDE & SCHWARZ
NRVD 102051 2017.03.29
100V Insertion Unit ROHDE & SCHWARZ
URV5-Z4 100464 2017.03.29
Pre-Amplifier ROHDE & SCHWARZ
1129588 2017.03.29
Loop Antenna ETS-Lindgren
6502
00104905
2017.04.28
Horn Antenna Chengdu AINFO
lnc. JXTXLB-10180-SF
J2031090903006
2017.06.27
Standard Gain Horn Antenna
Chengdu AINFO lnc.
JXTXLB-42-15-C-KF J20211007210
01 2017.06.27
Signal Analyzer Agilent
Technologies MXA N9020A MY46472144 2017.01.19
Oscilloscope Agilent
Technologies Infiniium DSO80204B MY46002024 2017.01.19
Power Sensor Agilent
Technologies U2022XA MY53470002 2017.11.21
RE Test software ROHDE & SCHWARZ
ESxS-K1 V2.10 N/A
Electrostatic Discharge(ESD)
Dehumidifier Kawasima
electrical appliance Co.,Ltd
DH-820H N/A N/A
Thermohygrograph SATO KEIRYOKI MFG.CO.,LTD.
7210-00 1633581 2017.08.11
BAROGRAPH SATO KEIRYOKI MFG.CO.,LTD.
NSII-BQ 567719 2016.12.02
ESD Simulator TESEQ NSG 438 873 2017.03.18
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 8 von 31 Page 8 of 31
Test Equipment Manufacturer Model Serial No. Cal. Due Date
Electrical Fast Transient(EFT) & Surge & Voltage Dips and Interruptions
Transient Immunity Test System
EMC-PARTNER TRANSIENT2000 845 2017.03.29
Transient Immunity Tester
TESEQ NSG3040 1819 2017.03.29
Test software EMC PARTNET Test-Manager V1.71 N/A
Conducted Susceptibility (150kHz-80MHz)
DUAL DIRECTIONAL COUPLER
AMPLIFIER RESEARCH
DC2600A 308682 2017.03.29
Amplifier AMPLIFIER RESEARCH
75A250A 308682 2017.03.29
Power meter ROHDE & SCHWARZ
NRVD 100987 2017.01.19
Signal Generator ROHDE & SCHWARZ
SML01 102439 2017.03.29
Coupling Decoupling Network
Fischer Custom Communications
Inc 30W1000B 4022 2017.03.29
CI Test software ROHDE & SCHWARZ
EMC32 V5.20.0 N/A
Radiated Susceptibility
Power meter ROHDE & SCHWARZ
NRVD 102051 2017.03.29
Signal Generator ROHDE & SCHWARZ
SMB100A 1406600K02-104532-DF
2017.03.29
Biconilog Antenna ETS.LINDGREN 3142C 00060445 2017.11.15
Power Amplifier BONN
ELEKTRONIK BLWA0840-50/30D 066454B 2017.03.29
Power Amplifier BONN
ELEKTRONIK BLWA0810-250/100D 066454A 2017.03.29
RI Test software ROHDE & SCHWARZ
EMC32 V8.40.0 2017.03.29
: Used / : Not used
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 9 von 31 Page 9 of 31
3. General Product Information
The 36 new submitted samples are LED Strip Light with general light source of LED module, but without LED driver and electronic control circuit. The all models have the similar PCB and electric circuit except structure. Mode list: DX-2835-30D-5MM DX-3528-30D-5MM DX-5050-30D-8MM
DX-2835-30D-8MM DX-3528-30D-8MM DX-5050-30D-10MM
DX-2835-30D-10MM DX-3528-30D-10MM DX-5050-45D-8MM
DX-2835-45D-5MM DX-3528-45D-5MM DX-5050-45D-10MM
DX-2835-45D-8MM DX-3528-45D-8MM DX-5050-60D-8MM
DX-2835-45D-10MM DX-3528-45D-10MM DX-5050-60D-10MM
DX-2835-60D-5MM DX-3528-60D-5MM DX-5050-60D-12MM
DX-2835-60D-8MM DX-3528-60D-8MM DX-5730-30D-10MM
DX-2835-60D-10MM DX-3528-60D-10MM DX-5730-45D-10MM
DX-2835-60D-12MM DX-3528-60D-12MM DX-5730-60D-10MM
DX-2835-120D-12MM DX-3528-120D-12MM DX-5730-60D-12MM
DX-2835-120D-15MM DX-3528-120D-15MM DX-5730-60D-15MM According to above information, full tests are performed on model DX-5730-60D-10MM, the same as DM125278 on Appendix 1. For details please refer to the Technical Documentation.
3.1 Product Function and Intended Use
Refer to Technical Documentation.
3.2 Ratings and System Details
Type designation: refer to section 3 Rated input: DC 12V Rated power: 14.4W Protection class: III Ports: DC port
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 10 von 31 Page 10 of 31
3.3 Independent Operation Modes
The basic operation modes are: A: On B: Off Refer to the Technical Documentation for further information.
3.4 Noise Generating and Noise Suppressing Parts
Refer to the Technical Documentation for further information.
3.5 Submitted Documents
Difference description Construction Drawing Circuit Diagram PCB Layout Part List Rating Label User Manual
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 11 von 31 Page 11 of 31
4. Test Set-up and Operation Modes
4.1 Principle of Configuration Selection
Emission: The equipment under test (EUT) was configured to measure its highest possible radiation level. The test modes were adapted accordingly in reference to the instructions for use. Immunity: The equipment under test (EUT) was configured to have its highest possible susceptibility against the tested phenomena. The test modes were adapted accordingly in reference to the instructions for use.
4.2 Physical Configuration for Testing
Refer to relative paragraphs of this test report.
4.3 Test Operation and Test Software
Refer to test setup in chapter 5 and chapter 6.
4.4 Special Accessories and Auxiliary Equipment
None.
4.5 Countermeasures to achieve EMC Compliance
No additional countermeasures to the submitted test sample(s) were employed to achieve compliance.
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 12 von 31 Page 12 of 31
5. Test Results E M I S S I O N
5.1 Emission in the Frequency Range up to 30 MHz
5.1.1 Harmonics Current Emission on AC Mains
RESULT: N/A
Test Specification Basic standard : EN 61000-3-2:2014 Measurement equipment requirement : IEC 61000-4-7 Measured harmonics : 1 – 40 Equipment class : C Limits : Clause 7.3 The EUT with nominal voltage less than 220V (line-to-neutral) will not intend to be directly connected to pubic low-voltage distribution systems, so this test is not applicable.
5.1.2 Voltage Changes, Voltage Fluctuations and Flicker
RESULT: N/A
Test Specification Basic standard : EN 61000-3-3:2013 Measurement equipment requirement : IEC 61000-4-15 Limits : EN 61000-3-3:2013, Clause 5 The EUT with nominal voltage less than 220V (line-to-neutral) will not intend to be directly connected to pubic low-voltage distribution systems, so this test is not applicable.
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 13 von 31 Page 13 of 31
5.1.3 Terminal Continuous Disturbance Voltage
RESULT: Pass
Test Specification Test procedure : EN 55015:2013, EN 55015:2013+A1 Port : DC port Frequency range of Mains : 9kHz-30MHz Test site : Shielded Room Limits : EN 55015:2013+A1, Clause 4.3.1, Table 2a Test Setup Date of testing : 08 Oct 2016 Input voltage : DC 12V Operation mode : On Artificial hand : N/A Test configuration : Table-top Temperature : 25°C Humidity : 54% Air pressure : 101kPa
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 14 von 31 Page 14 of 31
Photograph 1: Set-up for Continuous Disturbance Voltage
Test Result Measurement uncertainty: 3.2dB (k=2, σ= 95%) If the result of the measurement with the Quasi Peak detector is below the Average limit, the measurement with Average Detector has been omitted. Disturbances other than those mentioned are small or not detectable.
Refer to the attached appendix 1.
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 15 von 31 Page 15 of 31
5.1.4 Radiated Electromagnetic Disturbances
RESULT: Pass
Test Specification Test procedure : EN 55015:2013, Clause 9 EN 55015:2013+A1 Port : Enclosure Frequency range : 9kHz-30MHz Test site : Shielded Room Limits : EN 55015:2013+A1, Clause 4.4,
Table 3a Test Setup Date of testing : 29 Sep 2016 Input voltage : DC 12V Operation mode : On Temperature : 25°C Humidity : 54% Air pressure : 101kPa
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 16 von 31 Page 16 of 31
Photograph 2: Set-up for Radiated Electromagnetic Disturbances
Test Result Measurement uncertainty: 3.3dB (k=2, σ= 95%) Refer to the attached appendix 1.
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 17 von 31 Page 17 of 31
5.2 Emission in the Frequency Range above 30 MHz
5.2.1 Radiated Disturbance
RESULT: Pass
Test Specification Test procedure : EN 55015:2013, Clause 9
EN 55015:2013+A1 Port : Enclosure Frequency range : 30MHz -300MHz Test site : SAR Limits : EN 55015:2013+A1, Clause 4.4, Table 3b Test Setup Date of testing : 29 Sep 2016 Input voltage : DC 12V Operation mode : On Temperature : 24.5°C Humidity : 55% Air pressure : 101kPa
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 18 von 31 Page 18 of 31
Photograph 3: Set-up for Radiated Disturbance
Test Result Measurement uncertainty: 4.6dB (k=2, σ= 95%) Disturbances other than those mentioned are small or not detectable. Refer to the attached appendix 1.
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 19 von 31 Page 19 of 31
6 . Test Results I M M U N I T Y
6.1 Classification of Apparatus
According to EN 61547:2009, the appliance shall fulfill the requirements of:
Continuous Disturbances
Power-frequency magnetic field Criterion A
Radio-Frequency Common Mode / Conducted Susceptibility (CS) Criterion A
Radio-frequency Electromagnetic Fields (RS) Criterion A
Transient Disturbances
Electrical Fast Transients (EFT) Criterion B
Surge Criterion C
Electrostatic Discharges (ESD) Criterion B
Power Supply Alterations
Voltage Dips and Interruptions Criterion B + C
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 20 von 31 Page 20 of 31
6.2 Continuous Disturbances
6.2.1 Power-frequency Magnetic Fields
RESULT: N/A
Test Specification Family Standard : EN 61547:2009 Basic standard : IEC 61000-4-8 Test Level (A/m) : 3A/m Frequency : 50Hz and 60Hz Performance criterion : A The immunity against power frequency magnetic field was not tested because the EUT does not contain components, which are susceptible to magnetic fields. According to EN 61547:2009, clause 5.4: “these tests need only to be applied to equipment containing components susceptible to magnetic fields.”
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 21 von 31 Page 21 of 31
6.2.2 Radio-frequency Common Mode / Conducted Susceptibility (CS)
RESULT: Pass
Test Specification Family standard : EN 61547:2009 Basic standard : IEC 61000-4-6 Characteristics of the test generator : Output impedance : 50 Ω Harmonics and distortion Any spurious spectral line at least 15 dB
below the carrier level Amplitude modulation : 80 % ± 5 % in depth, 1 kHz ± 10 % sine
wave Frequency bandwidth : 150 kHz to 80MHz Frequency step : 1% with 1 s dwell time Performance criterion : A Test Setup Date of testing : 08 Oct 2016 Input voltage : DC 12V Operation mode : On Artificial hand : N/A Signal lines and control lines : N/A Output dc power ports : N/A Input dc power ports : 3V (rms) Temperature : 23°C Humidity : 56% Air pressure : 101kPa
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 22 von 31 Page 22 of 31
Photograph 4: Set-up for Radio-frequency Common Mode / Conducted Susceptibility (CS)
Test Result
Table 2: Immunity against Radio-frequency Common Mode / Conducted Susceptibility (CS)
Coupling point Application Level (V(r.m.s)) Remark Power ports DC input port CDN-M2 3 Applied, *) Signal and control lines Current Clamp 3 N/A EM clamp 3 N/A
*) Remark: No degradation was found.
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 23 von 31 Page 23 of 31
6.2.3 Radio-frequency Electromagnetic Fields (RS)
RESULT: Pass
Test Specification Family standard : EN 61547:2009 Basic standard : IEC 61000-4-3 Test site : FAC Uniform field area (UFA) : 1.5 m x 1.5 m, 16 points with a minimum UFA size 0.5 m x 0.5 m,75 % of calibration points within specifications if UFA is larger than 0.5 m x 0.5 m . 100 % (all 4 points) in the specifications for 0.5 x 0.5 m UFA Amplitude modulation : 80 % ± 5 % in depth, 1 kHz ± 10 % sine wave Frequency bandwidth : 80MHz to 1000MHz Level : 3 V/ m (un-modulated) Frequency step : 1% with 1 s dwell time Performance criterion : A Test Setup Date of testing : 30 Sep 2016 Input voltage : DC 12V Operation mode : On Artificial hand : N/A Temperature : 25°C Humidity : 53% Air pressure : 101kPa
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 24 von 31 Page 24 of 31
Photograph 5: Set-up for Radio-frequency Electromagnetic Fields (RS)
Test Result
Table 3: Immunity against Radio-frequency Electromagnetic Fields (RS)
Side of the equipment under test
Frequency (MHz) Antenna polarization (Vertical/Horizontal)
Remark
Front 80-1000 V and H Applied, *) Rear 80-1000 V and H Applied, *) Right 80-1000 V and H Applied, *) Left 80-1000 V and H Applied, *)
*) Remark: No degradation was found.
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 25 von 31 Page 25 of 31
6.3 Transient Disturbances
6.3.1 Electrical Fast Transients (EFT)
RESULT: Pass
Test Specification Family standard : EN 61547:2009 Basic standard : IEC 61000-4-4 Wave shape of the pulse in 50 Ω load : Rise time 5 ns ± 30 % Duration 50 ns ± 30 % Wave shape into 1 kΩ load : Rise time 5 ns ± 30 % Duration 50 ns with a tolerance of -15 ns to+100 nsBurst duration : 15 ms ± 20 % at 5 kHz Burst period : 300 ms ± 20 % Repetition frequency : 5 kHz Polarity : Positive and negative Time of application : 2 minutes Performance criterion : B Test Setup Date of testing : 08 Oct 2016 Input voltage : DC 12V Operation mode : On Artificial hand : N/A Signal and telecommunication ports : N/A Output dc power ports : N/A Input dc power ports : 0.5kV Temperature : 23°C Humidity : 56% Air pressure : 101kPa
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 26 von 31 Page 26 of 31
Photograph 6: Set-up for Electrical Fast Transient (EFT)
Test Result
Table 4: Immunity against Electrical Fast Transients (EFT)
Coupling point Application Level (kV) Polarity Remark Power ports AC power port Coupling
network 1 + N/A 1 - N/A
DC power port Coupling network
0.5 + Applied *)0.5 - Applied *)
Signal lines Coupling clamp 0.5 + N/A 0.5 - N/A Control lines Coupling clamp 0.5 + N/A 0.5 - N/A
*) Remark: No degradation was found.
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 27 von 31 Page 27 of 31
6.3.2 Surge
RESULT: N/A
Test Specification Family standard : EN 61547:2009 Basic standard : IEC 61000-4-5 Definitions of the waveform parameters : Front time 1.2 µs ± 30 %
Time to half value 50 µs ± 20 %
Source impedance : Power line symmetrical
Power line unsymmetrical
2 Ω + 18 µF
12 Ω + 9 µF
Polarity : Positive and negative Number of surges / polarity /phase angle : 5 Phase angles : 90° and 270 ° Repetition rate : 60 s Performance criterion : C The EUT is powered by DC power. Therefore, this test is not applicable and skipped.
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 28 von 31 Page 28 of 31
6.3.3 Electrostatic Discharges (ESD)
RESULT: Pass
Test Specification Family standard : EN 61547:2009 Basic standard : IEC 61000-4-2 Discharge impedance : 330 Ω / 150 pF Number of discharges : ≥ 10 Type of discharge : Direct discharge Air discharge, ±2,4,8kV
Contact discharge, ±4kV Indirect discharge Contact discharge, ±4kV
Polarity : Positive and negative Discharge location : See photo documentation of the test set-up All external locations accessible by hand Horizontal coupling plate (HCP) Vertical coupling plate (VCP) Performance criterion : B Test Setup Date of testing : 30 Sep 2016 Input voltage : DC 12V Operation mode : On Temperature : 24°C Humidity : 52% Air pressure : 101kPa
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 29 von 31 Page 29 of 31
Photograph 7: Set-up for Electrostatic Discharge
Contact Discharge ±4kV Air Discharge ±2,4,8kV
Test Result
Table 5: Electrostatic Discharge
Direct discharges Air discharges Discharge location
Air discharge voltage (kV)
Polarity Remark
Non-conductive parts 2,4,8 +/- Applied *) Contact discharges Discharge location
Contact discharge voltage (kV)
Polarity Remark
Conductive parts 4 +/- Applied *) Indirect discharges Contact discharges Discharge location
Contact discharge voltage (kV)
Polarity Remark
HCP 4 +/- Applied *)VCP 4 +/- Applied *)
*) Remark: No degradation was found.
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 30 von 31 Page 30 of 31
6.4 Power Supply Alterations
6.4.1 Voltage Dips and Interruptions
RESULT: N/A
Test Specification Family standard : EN 61547:2009 Basic standard : IEC 61000-4-11 Test voltage generator characteristics for interruptions: Rise time Between 1 µs and 5 µs Fall time Between 1 µs and 5 µs Output impedance of test voltage generator : <(0.4 + j 0.25 Ω) Phase angle : 0° Nominal mains voltage (Ut) : DC 12V Rated frequency : -- Test level : Test level in % Ut Duration (cycle) 0 0.5 70 10 Number of interruptions : 3 Number of voltage dips : 3 Interval : >10s Performance criterion : B+C The EUT is powered by DC power. Therefore, this test is not applicable and skipped.
Produkte Products
Prüfbericht - Nr.: Test Report No.
16078925 001 Seite 31 von 31 Page 31 of 31
7. List of Tables
Table 1: List of Test and Measurement Equipment ................................................................................................. 6 Table 2: Immunity against Radio-frequency Common Mode / Conducted Susceptibility (CS) ..................... 22 Table 3: Immunity against Radio-frequency Electromagnetic Fields (RS) ........................................................ 24 Table 4: Immunity against Electrical Fast Transients (EFT) ................................................................................ 26 Table 5: Electrostatic Discharge ............................................................................................................................... 29
8. List of Photographs
Photograph 1: Set-up for Continuous Disturbance Voltage ................................................................................. 14 Photograph 2: Set-up for Radiated Electromagnetic Disturbances .................................................................... 16 Photograph 3: Set-up for Radiated Disturbance .................................................................................................... 18 Photograph 4: Set-up for Radio-frequency Common Mode / Conducted Susceptibility (CS) ....................... 22 Photograph 5: Set-up for Radio-frequency Electromagnetic Fields (RS) .......................................................... 24 Photograph 6: Set-up for Electrical Fast Transient (EFT) .................................................................................... 26 Photograph 7: Set-up for Electrostatic Discharge .................................................................................................. 29
Produkte Products
Appendix 1
Prüfbericht - Nr.: Test Report no.:
16078925 001 Seite 1 von 12 Page 1 of 12
Produkte Products
Appendix 1
Prüfbericht - Nr.: Test Report no.:
16078925 001 Seite 2 von 12 Page 2 of 12
Produkte Products
Appendix 1
Prüfbericht - Nr.: Test Report no.:
16078925 001 Seite 3 von 12 Page 3 of 12
Produkte Products
Appendix 1
Prüfbericht - Nr.: Test Report no.:
16078925 001 Seite 4 von 12 Page 4 of 12
Produkte Products
Appendix 1
Prüfbericht - Nr.: Test Report no.:
16078925 001 Seite 5 von 12 Page 5 of 12
Produkte Products
Appendix 1
Prüfbericht - Nr.: Test Report no.:
16078925 001 Seite 6 von 12 Page 6 of 12
Produkte Products
Appendix 1
Prüfbericht - Nr.: Test Report no.:
16078925 001 Seite 7 von 12 Page 7 of 12
Produkte Products
Appendix 1
Prüfbericht - Nr.: Test Report no.:
16078925 001 Seite 8 von 12 Page 8 of 12
Produkte Products
Appendix 1
Prüfbericht - Nr.: Test Report no.:
16078925 001 Seite 9 von 12 Page 9 of 12
Produkte Products
Appendix 1
Prüfbericht - Nr.: Test Report no.:
16078925 001 Seite 10 von 12 Page 10 of 12
Produkte Products
Appendix 1
Prüfbericht - Nr.: Test Report no.:
16078925 001 Seite 11 von 12 Page 11 of 12
Produkte Products
Appendix 1
Prüfbericht - Nr.: Test Report no.:
16078925 001 Seite 12 von 12 Page 12 of 12