Single-cycle mixed-fluid LNG (PRICO) process

Part II: Optimal operation

Sigurd Skogestad & Jørgen Bauck Jensen

Qatar, January 2009

2

Single-cycle mixed fluid LNG process

Natural gas:• Feed at 40 bar and 30 °C• Cool to -157 °C (spec.)• ΔP = 5 bar in main heat

exchanger

3

Single-cycle mixed fluid LNG process

Refrigerant:• Partly condensed with sea

water• Subcooled to ~ -157 °C• Expansion to ~ 4 bar• Evaporates in main HX• Super-heated 10 °C• Compressed to ~ 30 bar

30 bar

-157 °C

26 bar

4 bar

Sup 10 °C

Sat. liquid

Subcooled

4

Degrees of freedom

Manipulated variables:

1. Compressor speed N

2. Choke valve opening z

3. Turbine power

4. Sea water flowrate

5. Natural gas feed flowrate

6-9. Composition of refrigerant (4)

6-9

5

Degrees of freedom

Assumptions:

1. Assume maximum cooling in SW cooler• Realized by fixing T=30 °C

• 8 degrees of freedom for optimization

• 4 degrees of freedom in operation– Assume 4 constant

compositions in operation

6

Operational constraints

• Some super-heating to avoid damage to compressor– But we find that super-heating is optimal anyway…. (constraint not

active)

• Maximum compressor power 120 MW– active

• Maximum compressor rotational speed is 100 %– active

• Minimum distance to surge is 0 kg/s (no back-off)– active

7

Optimal operation

Minimize operation cost with respect to the • 8 degrees of freedom (u)• subject to the constraints c ≤ 0

9

Two modes of operation

• Mode I: Given production rate (mfeed)Optimization problem simplifies to

– Minimize compressor work (Ws)

• Mode II: Free production rateWith reasonably high LNG prices:

Optimization problem simplifies to

– Maximize production rate (mfeed)

while satifying operational constraints (max. compressor load)

11

Mode I: Nominal optimum

• Feed flowrate is given (69.8 kg/s)– 8 - 1 = 7 steady-state degrees of freedom (incl. 4 compositions)

• Three operational constraints are active at optimum1. Given temperature LNG (-157 °C)

2. Compressor surge margin at minimum (0.0 kg/s)

3. Compressor speed at maximum (100 %)

• Only the four degrees of freedom related to refrigerant compositions are unconstrained

12

Nominal optimum

13

Mode II: Nominal optimum

• LNG production is maximized– 8 steady-state degrees of freedom (incl. 4 compositions)

• Four operational constraints are active at optimum1. Given temperature LNG (-157 °C)

2. Compressor surge margin at minimum (0.0 kg/s)

3. Compressor speed at maximum (100 %)

4. Compressor work Ws at maximum (120 MW)

• Note that two capacity constraints are active (3 and 4)• Only the four constraints related to refrigerant

composition are unconstrained

14

Nominal optimum

15

Nominal compressor operating point for mode II

N=100% (max speed)

N=50%

N=10%

* Surge limit

16

Temperature profiles in heat exhanger (mode II)

TNG-TC

NG in

LNG out

17

Optimum with disturbances

• 4 operational degrees of freedom– Refrigerant composition is constant during operation

Optimum with disturbances:

1. Given LNG temperature (all cases)

2. Given load (all cases)– Mode I: The production rate is given

– Mode II: The compressor work is at maximum (Ws = 120 MW)

3. Max. speed compressor (most cases)

4. Operate at surge limit (most cases)

20

Check Mode II(production vs. disturbance)

• Dots are re-optimized• Lines are for different controlled variables constant• Constant distance to surge (0.0 kg/s) (ALL CASES)

• N=Nmax gives highest production (CLOSE TO OPTIMAL)

• N=Nmax only feasible structure in increasing load direction

21

Example of control structure

TC

Max cooling

Max speed

WCWs,max=120MW

SCΔmsurge=0

m

Alternative: MPC

22

Conclusion

• Maximum compressor speed and minimum distance to surge is nominally optimal for mode I and mode II– In practice one would have a back-off from surge, but this would

still be an active constraint

• This is also close to optimal or optimal for all disturbance regions

Control the following variables:1. Maximum sea water cooling (valve fully open)

2. TLNG = -157 °C

3. LNG flowrate = 69.8 kg/s (mode I) or Ws = 120 MW (mode II)

4.

5.

23

Additional material

1. Disturbances considered

2. Structure of model equations

3. Data used for the PRICO process

24

Disturbances considered

25

Structure of model equations

26

Data used for the PRICO process