INALA TECHNOLOGIESTEST PROCEDURE: ECS2, SAM2, SAM1.5 & ACCESS

VERSION 1.0

2 | SAM Training

TESTING SUMMARY

1. Set up SAM2.2. Set up ECS2 communication controller.3. Test communication to SAM1.5 or SAM2 unit via ECS2 coms Controller4. Test communication to Access Control unit via ECS2 coms Controller

3 |

SAM2 SET UP – VIA RS232

4 | SAM Training

SAM2 – RS232

RS232 Communication Test;• Connect a straight RS232 cable between the Lap Top and the

SAM2 RS232 port(DB9 Connector on front panel• Open SAM2 ECT

• Select “Com Port” and double click on “Password”

5 | SAM Training

SAM2 – SET UP VIA RS232 CONTINUED

RS232 Communication Test; Cont;• Active communication will be shown on the

bottom left as indicated with the RED circle until it says “received”

1. Click on “Load Config” and select the applicable config file.

2. Click on “Update SAM” and wait until SAM has been updated – This can be seen on the bottom left as indicated with the RED circle until it says “received”

3. Click on “Sync Time”4. Click on “Get Config” and ensure that

SAM2 shows you the current date and time.

5. Capture SAM2 Serial number.6. Click on “Update”7. Click on “Set Config”

12

3

4

5 6

7

6 | SAM Training

SAM2 – SET UP VIA RS232 CONTINUED

RS232 Communication Test; Cont;1. Click on “Alarm Configuration” tab2. Select “RS485” under “Coms Config”3. Click on “Set”4. Click on “Get Config”5. Click on “Set Config”

• Check that “Intruder” alarm is number “9”• Check that “Movement” alarm is number “11”

Close SAM2 ECT

1

23

45

7 |

ECS2 COMMUNICATION CONTROLLER SET-UP

8 | SAM Training

ECS2 COMS CONTROLLER – SET UP

ECS2 Coms Controller Set up;• Connect a USB printer cable between the Lap Top and the

ECS2 Coms Controller USB port.• Open ECS2 ECT

• Select “USB” and click on “Login”

1

2

9 | SAM Training

ECS2 COMS CONTROLLER – SET UP

ECS2 Set Up:• Check that the units has the latest

Firmware version being “Build 1.6”• If Not on latest version, upgrade to

latest version1. Click on “Upgrade to V1.6”2. Click on “File” then “Load Config”3. Click on “Update uniit” 4. Click on “Site Inventory”

1

2

3

4

10 | SAM Training

ECS2 COMS CONTROLLER – SET UP

ECS2 Set Up:1. Capture ECS2 Coms Controller

Serial number.2. Click on “Update unit” 3. Click on “Configuration” Tab4. Click on “Update unit”5. Close ECS2 ECT

12

3

11 |

TESTING COMMUNICATION TO THE SAM OR ACCESS CONTROL UNITVIA THE ECS2 COMMUNICATION CONTROLLER

12 |

SAM2 COMMUNICATION TESTVIA THE ECS2 COMMUNICATION CONTROLLER

13 | SAM Training

SAM2 – COMMUNICATION TEST VIA ECS2 COMMUNICATION CONTROLLER – “RS485”

RS485 Communication Test;• Connect a USB printer cable between the Lap Top and the

ECS2 communication Controller USB port• Open SAM2 ECT

• Select “TCP” and insert 192.168.11.1 (USB IP Address) and Port 301 and double click on “Password”

14 | SAM Training

SAM2 – COMMUNICATION TEST VIA ECS2 COMMUNICATION CONTROLLER – “RS485”

RS485 Communication Test; Cont;• Active communication will be shown on the

bottom left as indicated with the RED circle until it says “received”

15 |

SAM1.5 COMMUNICATION TESTVIA THE ECS2 COMMUNICATION CONTROLLER

16 | SAM Training

SAM1.5 – COMMUNICATION TEST VIA ECS2 COMMUNICATION CONTROLLER – “RS485”

RS485 Communication Test;• Connect a USB printer cable between the Lap Top and the

ECS2 communication Controller USB port• Open SAM1.5 ECT

• Select “TCP” and insert 192.168.11.1 (USB IP Address) and Port 310 and double click on “Password”

17 | SAM Training

SAM1.5 – COMMUNICATION TEST VIA ECS2 COMMUNICATION CONTROLLER – “RS485”

RS485 Communication Test; Cont;• Active communication will be shown on the

bottom left as indicated with the RED circle until it says “received”

18 |

ACCESS CONTROL COMMUNICATION TESTVIA THE ECS2 COMMUNICATION CONTROLLER

19 | SAM Training

ACCESS CONTROL – COMMUNICATION TEST VIA ECS2 COMMUNICATION CONTROLLER – “RS485”

RS485 Communication Test; Cont;1. Click on “TCP” and insert IP address

192.168.11.1.2. Click on “Connect”3. Click on “Logon”4. Click on “Open Door”5. Click on “Get Version”6. Click on “Get Time”7. Click on “Log off”8. Click on “Exit”

• Responses should be received as indicated in the Red circle

1

2 3

4

5

6

6 7